DPO2004B [ETC]

Mixed Signal Oscilloscopes; 混合信号示波器
DPO2004B
型号: DPO2004B
厂家: ETC    ETC
描述:

Mixed Signal Oscilloscopes
混合信号示波器

文件: 总18页 (文件大小:1031K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Mixed Signal Oscilloscopes  
MSO2000B Series, DPO2000B Series Datasheet  
Key features  
Wave Inspector® controls provide easy navigation and automated  
search of waveform data  
FilterVu variable low-pass filter allows for removal of unwanted signal  
noise while still capturing high-frequency events  
29 automated measurements, and FFT analysis for simplified waveform  
analysis  
TekVPI® probe interface supports active, differential, and current probes  
for automatic scaling and units  
7 in. (180 mm) wide-screen TFT-LCD color display  
Small footprint and lightweight - only 5.3 in. (134 mm) deep and 7 lb.  
14 oz. (3.6 kg)  
Five-year warranty  
Offering up to 200 MHz bandwidth and 1 GS/s sample rate, the MSO/  
DPO2000B Mixed Signal Oscilloscope Series from Tektronix delivers  
advanced debug features at an entry-level price. Quickly find and diagnose  
problems in complex designs with up to 20 channels for analyzing analog  
and digital signals. With a deep record length of 1 Mpoints standard on all  
channels, the MSO/DPO2000B lets you capture long windows of signal  
activity while maintaining fine timing resolution.  
Connectivity  
USB 2.0 host port on the front panel for quick and easy data storage  
USB 2.0 device port on rear panel for easy connection to a PC or direct  
printing to a PictBridge®-compatible printer  
Optional 10/100 Ethernet port for network connection and video-out port  
to export the oscilloscope display to a monitor or projector  
Key performance specifications  
200, 100, 70 MHz bandwidth models  
2 and 4 analog channel models  
Optional serial triggering and analysis  
Automated serial triggering, decode, and search options for I2C, SPI,  
CAN, LIN, and RS-232/422/485/UART  
16 digital channels (MSO series)  
1 GS/s sample rate on all channels  
1 megapoint record length on all channels  
5,000 wfm/s maximum waveform capture rate  
Suite of advanced triggers  
Datasheet  
Feature-rich tools for debugging mixed signal  
designs  
From triggering on specific packet content to automatic decode in multiple  
data formats, the MSO/DPO2000B Series provides integrated support for a  
broad range of serial buses - I2C, SPI, CAN, LIN, and RS-232/422/485/  
UART. The ability to decode up to two serial and/or parallel buses  
simultaneously means you gain insight into system-level problems quickly.  
Simplify and speed up debugging your complex design with feature-rich  
tools including Wave Inspector® controls for rapid waveform navigation and  
automated serial and parallel bus analysis.  
To further help troubleshoot system-level interactions in complex embedded  
systems, the MSO2000B Series offers 16 digital channels in addition to its  
analog channels. Since the digital channels are fully integrated into the  
oscilloscope, you can trigger across all input channels, automatically time-  
correlating all analog, digital, and serial signals.  
Comprehensive features speed every stage of  
debug  
The MSO/DPO2000B Series offers a robust set of features to speed every  
stage of debugging your design - from quickly discovering an anomaly and  
capturing it, to searching your waveform record for the event and analyzing  
its characteristics and your device's behavior.  
Discover  
To debug a design problem, first you must know it exists. Every design  
engineer spends time looking for problems in their design, a time-  
consuming and frustrating task without the right debug tools.  
The MSO/DPO2000B Series offers complete visualization of signals,  
providing fast insight into the real operation of your device. A waveform  
capture rate of 5,000 waveforms per second enables you to see glitches  
and other infrequent transients quickly, revealing the true nature of device  
faults. A digital phosphor display with intensity grading shows the history of  
a signal's activity by intensifying areas of the signal that occur more  
frequently, providing a visual display of just how often anomalies occur.  
Capture - Triggering on a specific transmit data packet going across an RS-232 bus. A  
complete set of triggers, including triggers for specific serial packet content, ensures you  
quickly capture your event of interest.  
Search  
Finding your event of interest in a long waveform record can be time  
consuming without the right search tools. With today's record lengths  
pushing to a million data points, locating your event can mean scrolling  
through thousands of screens of signal activity.  
The MSO/DPO2000B Series offers the industry's most comprehensive  
search and waveform navigation with its innovative Wave Inspector®  
controls. These controls speed panning and zooming through your record.  
A unique force-feedback system lets you move from one end of your record  
to the other in just seconds. You can mark any location you may want to  
reference later for further investigation, and automatically search the record  
using criteria that you define. Wave Inspector will instantly search your  
entire record, including analog, digital, and serial bus data. Along the way, it  
will automatically mark every occurrence of your defined event so you can  
quickly move between events.  
Discover - A waveform capture rate of 5,000 wfm/s maximizes the probability of capturing  
elusive glitches and other infrequent events.  
Capture  
Discovering a device fault is only the first step. Next, you must capture the  
event of interest to identify root cause.  
The MSO/DPO2000B Series provides a complete set of triggers - including  
runt, logic, pulse width/glitch, setup/hold violation, serial packet, and parallel  
data - to help quickly find your event. With up to a 1 Mpoint record length,  
you can capture many events of interest, even thousands of serial packets,  
in a single acquisition for further analysis while maintaining high resolution  
to zoom in on fine signal details.  
Search - I 2C decode showing results from a Wave Inspector search for Address value  
50. Wave Inspector controls provide unprecedented efficiency in viewing and navigating  
waveform data.  
2 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
Analyze  
Play/pause  
Verifying that your prototype's performance matches simulations and meets  
the project's design goals requires analyzing its behavior. Tasks can range  
from simple checks of rise times and pulse widths to sophisticated power  
loss analysis and investigation of noise sources.  
A dedicated play/pause front-panel button scrolls the waveform across the  
display automatically while you look for anomalies or an event of interest.  
Playback speed and direction are controlled using the intuitive pan control.  
Once again, turning the control further makes the waveform scroll faster and  
changing direction is as simple as turning the control the other way.  
The MSO/DPO2000B Series offers a comprehensive set of integrated  
analysis tools including waveform- and screen-based cursors, 29 automated  
measurements, and FFT analysis. Specialized application support for serial  
bus analysis is also available.  
Analyze - FFT analysis of a pulsed signal. A comprehensive set of integrated analysis  
tools speeds verification of your design's performance.  
®
Wave Inspector navigation and search  
A 1 M point record length represents thousands of screens of information.  
The MSO/DPO2000B Series enables you to search through it all and find  
your event in seconds with Wave Inspector, the industry's best tool for  
navigation and search.  
Wave Inspector controls provide unprecedented efficiency in viewing, navigating, and  
analyzing waveform data. Zip through your 1 Mpoint record by turning the outer pan  
control (1). Get from the beginning to end in seconds. See something of interest and  
want to see more details? Just turn the inner zoom control (2).  
Wave Inspector offers the following innovative controls:  
User marks  
Press the Set Mark front-panel button to place one or more marks on the  
waveform. Navigating between marks is as simple as pressing the  
Previous (←) and Next (→) buttons on the front panel.  
Zoom/pan  
A dedicated, two-tier front-panel control provides intuitive control of both  
zooming and panning. The inner control adjusts the zoom factor (or zoom  
scale); turning it clockwise activates zoom and goes to progressively higher  
zoom factors, while turning it counterclockwise results in lower zoom factors  
and eventually turning zoom off. No longer do you need to navigate through  
multiple menus to adjust your zoom view. The outer control pans the zoom  
box across the waveform to quickly get to the portion of waveform you are  
interested in. The outer control also utilizes force-feedback to determine  
how fast to pan on the waveform. The farther you turn the outer control, the  
faster the zoom box moves. Pan direction is changed by simply turning the  
control the other way.  
Search marks  
The Search button allows you to automatically search through your long  
acquisition looking for user-defined events. All occurrences of the event are  
highlighted with search marks and are easily navigated to, using the front-  
panel Previous (←) and Next (→) buttons. Search types include edge,  
pulse width/glitch, runt, logic, setup and hold, rise/fall time parallel bus, and  
I2C, SPI, CAN, LIN, and RS-232/422/485/UART packet content.  
www.tektronix.com  
3
Datasheet  
Search step 1: You define what you would like to find.  
Digital phosphor technology enables a 5,000 wfm/s waveform capture rate and real-time  
intensity grading on the MSO/DPO2000B Series.  
Mixed signal design and analysis (MSO  
series)  
The MSO2000B Series Mixed Signal Oscilloscopes provide 16 digital  
channels. These channels are tightly integrated into the oscilloscope's user  
interface, simplifying operation and making it possible to solve mixed-signal  
issues easily.  
Search step 2: Wave Inspector automatically searches through the record and marks  
each event with a hollow white triangle. You can then use the Previous and Next  
buttons to jump from one event to the next.  
Digital phosphor technology  
The MSO/DPO2000B Series' digital phosphor technology provides you with  
fast insight into the real operation of your device. Its waveform capture rate  
of 5,000 wfm/s gives you a high probability of quickly seeing the infrequent  
problems common in digital systems: runt pulses, glitches, timing issues,  
and more.  
The MSO Series provides 16 integrated digital channels enabling you to view and  
analyze time-correlated analog and digital signals.  
Waveforms are superimposed with one another and waveform points that  
occur more frequently are intensified. This quickly highlights the events that  
over time occur more often or, in the case of infrequent anomalies, occur  
less often.  
Color-coded digital waveform display  
The MSO2000B Series has redefined the way you view digital waveforms.  
One common problem shared by both logic analyzers and mixed-signal  
oscilloscopes is determining if data is a one or a zero when zoomed in far  
enough that the digital trace stays flat all the way across the display. The  
MSO2000B Series has color-coded digital traces, displaying ones in green  
and zeros in blue.  
With the MSO/DPO2000B Series, you can choose infinite persistence or  
variable persistence, determining how long the previous waveform  
acquisitions stay on-screen. This allows you to determine how often an  
anomaly is occurring.  
4 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
P6316 MSO probe  
This unique probe design offers two eight-channel pods, simplifying the  
process of connecting to the device-under-test. When connecting to square  
pins, the P6316 can connect directly to 8×2 square pin headers spaced on  
tenth-inch centers. When more attachment flexibility is required, you can  
use the included flying lead sets and grabbers to clip onto surface mount  
devices or test points. The P6316 offers outstanding electrical  
characteristics applying only 8 pF of capacitive loading with 101 kΩ input  
impedance.  
With the color-coded digital waveform display, groups are created by simply placing  
digital channels together on the screen, allowing the digital channels to be moved as a  
group. You can set threshold values for each pod of eight channels, enabling support for  
up to two different logic families.  
The P6316 MSO probe offers two eight-channel pods to simplify connecting to your  
device.  
FilterVu variable low-pass filter  
Tired of being limited to a 20 MHz bandwidth filter in your oscilloscope?  
Simply turn on FilterVu and adjust the variable low-pass noise filter. Unlike  
other variable low-pass filters, FilterVu filters out the unwanted noise from  
your signal while still capturing glitches and other signal details up to the full  
bandwidth of the oscilloscope. It does this by showing two waveforms: a  
waveform that can be filtered (foreground waveform) and a glitch capture  
waveform (background waveform).  
White edges indicate additional information is available by acquiring at a higher sample  
rate.  
The multiple transition detection hardware of the MSO2000B Series will  
show you a white edge on the display when the system detects multiple  
transitions. This acts as a visual reminder that increasing the sample rate on  
the next acquisition will reveal higher frequency information than your  
previous settings could acquire.  
The filtered waveform uses a variable low-pass filter to block out noise,  
yielding a cleaner waveform to more precisely locate signal edges and  
amplitude levels. The result is improved confidence in you cursor  
measurements and cleaner documentation of important signal attributes.  
When the noise filter is adjusted to the lowest available noise-cutoff  
frequency, no more than 1% of high-frequency content that could cause the  
oscilloscope to alias will pass through the filter.  
The MSO2000B Series simplifies channel setup by allowing you to group  
digital waveforms and enter waveform labels by using a USB keyboard. By  
simply placing digital waveforms next to each other, they form a group.  
Once a group is formed, you can position all the channels contained in that  
group collectively. This greatly reduces the normal setup time associated  
with positioning channels individually.  
The glitch capture waveform shows signal details up to the full bandwidth of  
the oscilloscope. The oscilloscope captures pulses as narrow as 5 ns, using  
peak-detect min/max sampling, protecting you from missing unexpected  
glitches or other high-frequency events.  
FilterVu is ideal for repetitive, nonrepetitive, and single-shot events.  
www.tektronix.com  
5
Datasheet  
Bus display  
Provides a higher-level, combined view of the individual signals (clock, data,  
chip enable, etc.) that make up your bus, making it easy to identify where  
packets begin and end and identifying subpacket components such as  
address, data, identifier, CRC, etc.  
Bus decoding  
Tired of having to visually inspect the waveform to count clocks, determine if  
each bit is a 1 or a 0, combine bits into bytes, and determine the hex value?  
Let the oscilloscope do it for you! Once you've set up a bus, the MSO/  
DPO2000B Series will decode each packet on the bus, and display the  
value in hex, binary, decimal (LIN only), or ASCII (RS-232/422/485/UART  
only) in the bus waveform.  
Output of DAC Signal - Notice how FilterVu clearly shows the noise-free steps of the  
DAC in the foreground trace (yellow) which has removed all frequencies above 5.5 kHz.  
FilterVu also captures and displays high-frequency glitches up to the full bandwidth of the  
oscilloscope in the background trace (orange).  
Event table  
Serial triggering analysis (optional)  
In addition to seeing decoded packet data on the bus waveform itself, you  
can view all captured packets in a tabular view much like you would see in a  
software listing. Packets are time stamped and listed consecutively with  
columns for each component (Address, Data, etc.).  
On a serial bus, a single signal often includes address, control, data, and  
clock information. This can make isolating events of interest difficult. The  
MSO/DPO2000B Series offers a robust set of tools for debugging serial  
buses with automatic trigger, decode, and search for I2C, SPI, CAN, LIN,  
and RS-232/422/485/UART.  
Serial triggering  
Trigger on packet content such as start of packet, specific addresses,  
specific data content, unique identifiers, etc. on popular serial interfaces  
such as I2C, SPI, CAN, LIN, and RS-232/422/485/UART.  
Event table showing decoded Identifier, DLC, DATA, and CRC for every CAN packet in a  
long acquisition.  
Search  
Serial triggering is very useful for isolating the event of interest, but once  
you've captured it and need to analyze the surrounding data, what do you  
do? In the past, users had to manually scroll through the waveform counting  
and converting bits and looking for what caused the event. With the MSO/  
DPO2000B Series, you can have the oscilloscope automatically search  
through the acquired data for user-defined criteria including serial packet  
content. Each occurrence is highlighted by a search mark. Rapid navigation  
between marks is as simple as pressing the Previous (←) and Next (→)  
buttons on the front panel.  
Triggering on a specific data packet going across an I 2 C bus. The yellow waveform is  
clock and the blue waveform is data. A bus waveform provides decoded packet content  
including Start, Address, Read/Write, Data, and Stop.  
6 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
Compact form factor  
Designed to make your work easier  
A compact, portable form factor allows the MSO/DPO2000B Series to be  
easily moved between labs and, with a depth of just 5.3 inches (134 mm), it  
saves you valuable space on your test bench.  
The MSO/DPO2000B is designed to make your work easier. The bright,  
widescreen display shows a long time window. Dedicated front-panel  
controls simplify operation. A USB host port on the front panel allows you to  
easily transfer screenshots, instrument settings, and waveform data to a  
memory st  
The MSO/DPO2000B Series' compact form factor frees up valuable space on your bench  
or desktop.  
®
TekVPI probe interface  
Bright, widescreen display  
The TekVPI probe interface sets the standard for ease of use in probing.  
TekVPI probes feature status indicators and controls, as well as a probe  
menu button right on the comp box itself. This button brings up a probe  
menu on the oscilloscope display with all relevant settings and controls for  
the probe. TekVPI probes can be controlled remotely through USB, GPIB,  
or Ethernet, enabling more versatile solutions in ATE environments.  
The MSO/DPO2000B Series features a 7 inch (180 mm) widescreen, TFT-  
LCD display for seeing intricate signal details.  
Dedicated front-panel controls  
Per-channel vertical controls provide simple and intuitive operation. No  
longer do you need to share one set of vertical controls across all four  
channels.  
Connectivity  
A USB host port on the front panel enables easy transfer of screenshots,  
instrument settings, and waveform data to a USB thumb drive. The rear  
panel contains a USB device port for controlling the oscilloscope remotely  
from a PC or for connecting a USB keyboard. The USB device port can also  
be used to print directly to a PictBridge®-compatible printer. An optional  
10/100 Ethernet port enables easy connection to networks and an optional  
Video Out port allows the oscilloscope display to be exported to an external  
monitor or projector.  
TekVPI probe interface simplifies connecting your probes to the oscilloscope.  
www.tektronix.com  
7
Datasheet  
Extended analysis  
Acquiring data and measurements from the MSO/DPO2000B Series is as  
simple as connecting a USB cable from the oscilloscope to your PC. Key  
software applications - OpenChoice® Desktop, and Microsoft Excel and  
Word toolbars - are included standard with each oscilloscope to enable fast  
and easy direct communication with your Windows PC.  
For simple tasks, the included OpenChoice Desktop enables fast and easy  
communication between the oscilloscope and your PC through USB, GPIB,  
or LAN for transferring settings, waveforms, and screen images.  
OpenChoice® Desktop software enables seamless connection between the oscilloscope  
and your PC.  
8 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
Specifications  
All specifications apply to all models unless noted otherwise.  
Model overview  
MSO2002B and  
DPO2002B  
MSO2004B and  
DPO2004B  
MSO2012B and  
DPO2012B  
MSO2014B and  
DPO2014B  
MSO2022B and  
DPO2022B  
MSO2024B and  
DPO2024B  
Analog channels  
Bandwidth 1  
2
4
2
4
2
4
70 MHz  
5 ns  
70 MHz  
5 ns  
100 MHz  
3.5 ns  
1 GS/s  
1 M points  
100 MHz  
3.5 ns  
1 GS/s  
1 M points  
200 MHz  
2.1 ns  
1 GS/s  
1 M points  
200 MHz  
2.1 ns  
1 GS/s  
1 M points  
Rise time  
Sample rate  
Record length  
Digital channels  
1 GS/s  
1 M points  
1 GS/s  
1 M points  
MSO models - add 16 digital channels to the corresponding DPO model  
Vertical system analog channels  
Hardware bandwidth limits  
Input coupling  
20 MHz  
AC, DC, GND  
Input impedance  
1 MΩ ±2%, 11.5 pF ±2 pF  
2 mV/div to 5 V/div  
8 bits  
Input sensitivity range  
Vertical resolution  
Maximum input voltage, 1 MΩ  
300 VRMS with peaks ≤ ±450 V  
DC gain accuracy (with offset set  
to 0 V)  
±3% for 10 mV/div to 5 V/div  
±4% for 2 mV/div to 5 mV/div  
Channel-to-channel isolation  
Offset range  
(Any two channels at equal vertical scale)  
MSO2002B, DPO2002B, MSO2004B,  
DPO2004B  
MSO2012B, DPO2012B, MSO2014B,  
DPO2014B  
MSO2022B, DPO2022B, MSO2024B,  
DPO2024B  
≥100:1 at ≤70 MHz  
≥100:1 at ≤100 MHz  
100:1 at ≤200 MHz  
Volts/div setting  
Offset range  
1 MΩ input  
±1 V  
2 mV/div to 200 mV/div  
>200 mV/div to 5 V/div  
±25V  
Vertical system digital channels  
Input channels  
16 digital (D15 to D0)  
Thresholds  
Threshold per set of 8 channels  
TTL, CMOS, ECL, PECL, User-defined  
± 20 V  
Threshold selections  
User-defined threshold range  
Threshold accuracy  
Maximum input voltage  
Input dynamic range  
±[100 mV + 3% of threshold setting]  
± 40 V  
80 Vpk-pk (threshold setting dependent)  
1
Bandwidth is 20 MHz at 2 mV/div, all models.  
www.tektronix.com  
9
Datasheet  
Minimum voltage swing  
500 mVp-p  
101 kΩ  
8 pF  
Input resistance  
Probe loading  
Vertical resolution  
1 bit  
Horizontal system analog channels  
Maximum duration of time  
captured at highest sample rate  
(all channels)  
1 ms  
Time base range  
200 MHz models: 2ns to 100s  
70, 100 MHz models: 4ns to 100s  
Time-base delay time range  
-10 divisions to 5000 s  
Channel-to-channel deskew range ±100 ns  
Time base accuracy  
±25 ppm over any ≥1 ms interval  
Horizontal system digital channels  
Maximum sample rate (main)  
When using any of channels D7 - D0  
When using any of channels D8 - D15  
1 GS/s (1 ns resolution)  
500 MS/s (2 ns resolution)  
Maximum record length (main, all 1 M points  
channels)  
Minimum detectible pulse width  
Channel-to-channel skew  
5 ns  
2 ns typical  
Trigger system  
Trigger modes  
Auto, Normal, and Single  
Trigger coupling  
DC, HF reject (attenuates >85 kHz), LF reject (attenuates <65 kHz), noise reject (reduces sensitivity)  
20 ns to 8 s  
Trigger holdoff range  
Trigger sensitivity, typical  
Trigger source  
Sensitivity  
Internal DC coupled  
0.4 div from DC to 50 MHz  
0.6 div > 50 MHz to 100 MHz  
0.8 div > 100 MHz to 200 MHz  
External (aux input)  
200 mV from DC to 100 MHz, 1X attenuation  
Trigger level ranges  
Any input channel  
±4.92 divisions from center of screen  
±6.25 V, 1X attenuation  
Aux Input (external trigger)  
±12.5 V, 10X attenuation  
Trigger types  
Edge  
Positive or negative slope on any channel or front-panel auxiliary input. Coupling includes DC, AC, HF reject, LF reject, and noise  
reject.  
Pulse Width  
Runt  
Trigger on width of positive or negative pulses that are >, <, =, ≠, or inside/outside a specified period of time.  
Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again.  
10 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
Logic  
Trigger when any logical pattern of channels goes false or stays true for specified period of time. Any input can be used as a clock  
to look for the pattern on a clock edge. Pattern (AND, OR, NAND, NOR) specified for all input channels defined as High, Low, or  
Don’t Care.  
Setup and Hold  
Trigger on violations of both setup time and hold time between clock and data present on any of the analog and digital input  
channels.  
Rise/Fall Time  
Video  
Trigger on pulse edge rates that are faster or slower than specified. Slope may be positive, negative, or either.  
Trigger on all lines, odd, even, or all fields on NTSC, PAL, and SECAM video signals.  
I2C (optional)  
Trigger on Start, Repeated Start, Stop, Missing ACK, Address (7 or 10 bit), Data, or Address and Data on I2C buses up to 3.4 Mb/s.  
Trigger on SS, MOSI, MISO, or MOSI and MISO on SPI buses up to 10.0 Mb/s.  
SPI (optional)  
RS-232/422/485/UART  
(optional)  
Trigger on Tx Start Bit, Rx Start Bit, Tx End of Packet, Rx End of Packet, Tx Data, Rx Data, Tx Parity Error, and Rx Parity Error up  
to 10 Mb/s.  
CAN (optional)  
Trigger on Start of Frame, Frame Type (data, remote, error, overload), Identifier (standard or extended), Data, Identifier and Data,  
End of Frame, Missing ACK, or Bit Stuffing Error on CAN signals up to 1 Mb/s. Data can be further specified to trigger on ≤, <, =, >,  
≥, or ≠ a specific data value. User-adjustable sample point is set to 50% by default.  
LIN (optional)  
Trigger on Sync, Identifier, Data, Identifier and Data, Wakeup Frame, Sleep Frame, Errors such as Sync, Parity, or Checksum  
Errors.  
Parallel (available on MSO  
models only)  
Trigger on a parallel bus data value.  
Acquisition system  
Acquisition Modes  
Sample  
Acquire sampled values.  
Peak Detect  
Averaging  
Roll  
Captures glitches as narrow as 3.5 ns at all sweep speeds.  
From 2 to 512 waveforms included in average.  
Scrolls waveforms right to left across the screen at sweep speeds slower than or equal to 40 ms/div.  
Waveform measurements  
Cursors  
Waveform and Screen.  
Automatic measurements  
29, of which up to four can be displayed on-screen at any one time. Measurements include: Period, Frequency, Delay, Rise Time,  
Fall Time, Positive Duty Cycle, Negative Duty Cycle, Positive Pulse Width, Negative Pulse Width, Burst Width, Phase, Positive  
Overshoot, Negative Overshoot, Peak to Peak, Amplitude, High, Low, Max, Min, Mean, Cycle Mean, RMS, Cycle RMS, Positive  
Pulse Count, Negative Pulse Count, Rising Edge Count, Falling Edge Count, Area and Cycle Area.  
Gating  
Isolate the specific occurrence within an acquisition to take measurements on, using either the screen, or waveform cursors.  
Waveform math  
Arithmetic  
Add, subtract, and multiply waveforms.  
FFT  
Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or  
Blackman-Harris.  
www.tektronix.com 11  
Datasheet  
Software  
®
OpenChoice Desktop  
Enables fast and easy communication between a Windows PC and your oscilloscope using USB or LAN. Transfer and save  
settings, waveforms, measurements, and screen images. Included Word and Excel toolbars automate the transfer of acquisition  
data and screen images from the oscilloscope into Word and Excel for quick reporting or further analysis.  
IVI driver  
Provides a standard instrument programming interface for common applications such as LabVIEW, LabWindows/CVI,  
Microsoft .NET, and MATLAB.  
®
e*Scope Web-based remote  
control  
Enables control of the oscilloscope over a network connection through a standard web browser. Simply enter the IP address or  
network name of the oscilloscope and a web page will be served to the browser.  
Display system  
Display type  
7 inch (180 mm) wide format liquid crystal TFT color display.  
480 horizontal × 234 vertical pixels (WQVGA).  
Vectors, Dots, Variable Persistence, Infinite Persistence.  
Full, Grid, Cross Hair, Frame.  
Display resolution  
Waveform styles  
Graticules  
Format  
YT and XY.  
Maximum waveform capture rate  
Up to 5,000 wfm/s.  
Input/output ports  
USB 2.0 high-speed host port  
USB 2.0 high-speed device port  
Supports USB mass storage devices, printers, and keyboards. One port available on rear panel and one on front panel.  
Rear-panel connector allows for communication/control of oscilloscope through USBTMC or GPIB with a TEK-USB-488, and direct  
®
printing to all PictBridge -compatible printers.  
LAN port (Ethernet)  
Video out port  
RJ-45 connector, supports 10/100BASE-T (requires DPO2CONN).  
DB-15 female connector, connect to show the oscilloscope display on an external monitor or projector (requires DPO2CONN).  
Front-panel BNC connector. Input Impedance 1 MΩ ±2%. Max input 300 VRMS CAT II with peaks ≤ ±450 V.  
Auxiliary input  
Probe compensator output voltage Front-panel pins  
and frequency  
Amplitude  
Frequency  
5 V  
1 kHz  
Kensington-style lock  
Rear-panel security slot connects to standard Kensington-style lock.  
Power source  
Power source voltage  
Power source frequency  
100 to 240 V ±10%  
45 to 65 Hz (90 to 264 V)  
360 to 440 Hz (100 to 132 V)  
Power consumption  
80 W maximum  
®
Optional TekVPI external power  
supply 2  
Output voltage  
Output current  
Power consumption  
12 V  
5 A  
50 W  
2
Required when total oscilloscope probe power usage exceeds 20 W.  
12 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
Physical characteristics  
Dimensions  
mm  
180  
377  
134  
in.  
Height  
Width  
Depth  
7.1  
14.9  
5.3  
Weight  
kg  
lb.  
Net  
3.6  
6.2  
7.9  
13.7  
Shipping  
Rackmount configuration  
Cooling clearance  
4U  
2 in. (50 mm) required on left side and rear of instrument  
EMC, environment, and safety  
Temperature  
Operating  
0 ºC to +50 ºC (+32 ºF to 122 ºF)  
-40 ºC to +71 ºC (-40 ºF to 160 ºF)  
Nonoperating  
Humidity  
Operating  
High: 30 ºC to 50 ºC, 5% to 60% relative humidity  
Low: 0 ºC to 30 ºC, 5% to 95% relative humidity  
High: 30 ºC to 55 ºC, 5%to 60% relative humidity  
Nonoperating  
Low: 0 ºC to 30 ºC, 5% to 95% relative humidity  
Altitude  
Operating  
Nonoperating  
3,000 meters (9,843 feet)  
12,000 meters (39,370 feet)  
Random vibration  
Operating  
0.31 GRMS from 5 to 500 Hz, 10 minutes each axis, 3 axes, 30 minutes total  
2.46 GRMS from 5 to 500 Hz, 10 minutes each axis, 3 axes, 30 minutes total  
Nonoperating  
Regulatory  
Electromagnetic compatibility EC Council Directive 2004/108/EC  
Safety UL61010-1:2004; CAN/CSA-C22.2 No. 61010.1: 2004; EN61010-1:2001; complies with the Low Voltage Directive 2004/108/EC for  
Product Safety.  
www.tektronix.com 13  
Datasheet  
Ordering information  
MSO/DPO2000B family  
DPO2002B  
DPO2004B  
DPO2012B  
DPO2014B  
DPO2022B  
DPO2024B  
MSO2002B  
MSO2004B  
MSO2012B  
MSO2014B  
MSO2022B  
MSO2024B  
70 MHz, 1 GS/s, 1 M record length, 2-channel digital phosphor oscilloscope  
70 MHz, 1 GS/s, 1 M record length, 4-channel digital phosphor oscilloscope  
100 MHz, 1 GS/s, 1 M record length, 2-channel digital phosphor oscilloscope  
100 MHz, 1 GS/s, 1 M record length, 4-channel digital phosphor oscilloscope  
200 MHz, 1GS/s, 1 M record length, 2-channel digital phosphor oscilloscope  
200 MHz, 1 GS/s, 1 M record length, 4-channel digital phosphor oscilloscope  
70 MHz, 1 GS/s, 1 M record length, 2+16 channel mixed-signal oscilloscope  
70 MHz, 1 GS/s, 1M record length, 4+16 channel mixed-signal oscilloscope  
100 MHz, 1 GS/s, 1M record length, 2+16 channel mixed-signal oscilloscope  
100 MHz, 1GS/s, 1M record length, 4+16 channel mixed-signal oscilloscope  
200 MHz, 1 GS/s, 1M record length, 2+16 channel mixed-signal oscilloscope  
200 MHz, 1 GS/s, 1 M record length, 4+16 channel mixed-signal oscilloscope  
Standard accessories  
Probes  
TPP0200  
200 MHz, 10x passive probe (one per analog channel) for 100 and 200 MHz models  
100 MHz, 10x passive probe (one per analog channel) for 70 MHz models  
16-channel logic probe and accessory kit (one per instrument)  
TPP0100  
P6316 (MSO models only)  
Accessories  
200-5045-xx  
063-4472-xx  
016-2008-xx  
071-3078 -xx  
Front protective cover  
Documentation CD  
Accessory pouch  
Installation and safety manual  
Power cord  
®
OpenChoice Desktop software  
Calibration certificate documenting traceability to National Metrology Institute(s) and ISO9001 quality system registration  
14 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
Warranty  
Five-year warranty covering all parts and labor, excluding probes.  
Application modules  
DPO2AUTO  
DPO2COMP  
DPO2EMBD  
Automotive Serial Triggering and Analysis Module. Enables triggering on packet-level information on CAN bus and LIN bus as well  
as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time  
stamp information.  
Computer Serial Triggering and Analysis Module. Enables triggering on packet-level information on RS-232/422/485/UART buses  
as well as analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables  
with time stamp information.  
Embedded Serial Triggering and Analysis Module. Enables triggering on packet-level information on I2C and SPI buses as well as  
analytical tools such as digital views of the signal, bus views, packet decoding, search tools, and packet decode tables with time  
stamp information. Only two-wire SPI support is available on two-channel models.  
Instrument options  
Power cord and plug options  
Please specify power plug version when ordering.  
Opt. A0  
Opt. A1  
Opt. A2  
Opt. A3  
Opt. A5  
Opt. A6  
Opt. A10  
Opt. A11  
Opt. A12  
Opt. A99  
North America power plug (115 V, 60 Hz)  
Universal Euro power plug (220 V, 50 Hz)  
United Kingdom power plug (240 V, 50 Hz)  
Australia power plug (240 V, 50 Hz)  
Switzerland power plug (220 V, 50 Hz)  
Japan power plug (100 V, 110/120 V, 60 Hz)  
China power plug (50 Hz)  
India power plug (50 Hz)  
Brazil power plug (60 Hz)  
No power cord  
Language options3 4  
Opt. L0  
Opt. L1  
Opt. L2  
Opt. L3  
Opt. L4  
Opt. L5  
Opt. L6  
Opt. L7  
English manual  
French manual  
Italian manual  
German manual  
Spanish manual  
Japanese manual  
Portuguese manual  
Simplified Chinese manual  
Traditional Chinese manual  
Opt. L8  
3
User manuals (PDF) in 11 languages are available on the CD and for download from http://www.tektronix.com/manuals. There are no printed user manuals.  
4
The English option includes a front-panel label on the instrument. The other language options include a front-panel overlay.  
www.tektronix.com 15  
Datasheet  
Opt. L9  
Korean manual  
Russian manual  
No manual  
Opt. L10  
Opt. L99  
Language options include translated front-panel overlay for the selected language(s).  
Service options  
Opt. D1  
Calibration Data Report  
Recommended accessories  
Probes  
Tektronix offers over 100 different probes to meet your application needs. For a comprehensive listing of available probes, please visit www.tektronix.com/probes.  
ADA400A  
P5100A  
100X, 10X, 1X, 0.1X high-gain differential amplifier 6 5  
2.5 kV, 500 MHz, 100X high-voltage passive probe  
6
®
TAP1500  
TCP0020  
TCP0030  
TCP0150  
TCP2020  
TCPA300/400  
TCP305  
1.5 GHz TekVPI active voltage probe  
6
®
50 MHz TekVPI 20 Ampere AC/DC current probe  
6
®
120 MHz TekVPI 30 Ampere AC/DC current probe  
6
®
20 MHz TekVPI 150 Ampere AC/DC current probe  
®
50 MHz TekVPI 20 Ampere AC/DC current probe  
Current measurement systems amplifier 7  
DC to 50 MHz 50 Ampere current probe for use with TCPA300  
DC to 2 MHz 500 Ampere current probe for use with TCPA400  
TCP404XL  
TDP0500  
THDP0200  
THDP0100  
TMDP0200  
6 8  
®
500 MHz TekVPI differential voltage probe with ±42 V differential input voltage  
±1.5 kV 200 MHz high-voltage differential probe 6  
±6 kV 100 MHz high-voltage differential probe 6  
±750 V 200 MHz high-voltage differential probe 6  
5
6
7
8
Requires TPA-BNC adapter.  
Requires TekVPI external power adapter (119-7465-00); one per oscilloscope.  
Requires 50 Ω feed through termination between the oscilloscope input and the BNC cable.  
Probes terminate into 50 Ω but oscilloscope will automatically adjust to account for 1 MΩ input.  
16 www.tektronix.com  
MSO/DPO2000B Series Mixed Signal Oscilloscope  
Accessories  
DPO2CONN  
077-0737-xx  
TPA-BNC  
Adds Ethernet (10/100Base-T) and video out port  
Service manual (English only) PDF-only, downloadable from www.tektronix.com/manuals  
®
®
TekVPI to TekProbe BNC adapter  
®
TEK-DPG  
TekVPI Deskew pulse generator signal source  
067-1686-xx  
196-3508-xx  
119-7465-xx  
TEK-USB-488  
ACD2000  
Power measurement deskew and calibration fixture  
Digital Probe Leadset (8 channels)  
®
TekVPI external power supply (power cord not included)  
GPIB-to-USB adapter  
Soft transit case  
200-5045-xx  
HCTEK4321  
RMD2000  
Front protective cover  
Hard transit case (requires ACD2000)  
Rackmount kit  
Tektronix is registered to ISO 9001 and ISO 14001 by SRI Quality System Registrar.  
Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats.  
www.tektronix.com 17  
Datasheet  
ASEAN / Australasia (65) 6356 3900  
Belgium 00800 2255 4835*  
Austria 00800 2255 4835*  
Brazil +55 (11) 3759 7627  
Balkans, Israel, South Africa and other ISE Countries +41 52 675 3777  
Canada 1 800 833 9200  
Central East Europe and the Baltics +41 52 675 3777  
Finland +41 52 675 3777  
Central Europe & Greece +41 52 675 3777  
France 00800 2255 4835*  
Denmark +45 80 88 1401  
Germany 00800 2255 4835*  
Hong Kong 400 820 5835  
India 000 800 650 1835  
Italy 00800 2255 4835*  
Japan 81 (3) 6714 3010  
Luxembourg +41 52 675 3777  
The Netherlands 00800 2255 4835*  
Poland +41 52 675 3777  
Russia & CIS +7 (495) 6647564  
Sweden 00800 2255 4835*  
Mexico, Central/South America & Caribbean 52 (55) 56 04 50 90  
Norway 800 16098  
Portugal 80 08 12370  
South Africa +41 52 675 3777  
Switzerland 00800 2255 4835*  
USA 1 800 833 9200  
Middle East, Asia, and North Africa +41 52 675 3777  
People's Republic of China 400 820 5835  
Republic of Korea 001 800 8255 2835  
Spain 00800 2255 4835*  
Taiwan 886 (2) 2722 9622  
United Kingdom & Ireland 00800 2255 4835*  
* European toll-free number. If not accessible, call: +41 52 675 3777  
Updated 10 April 2013  
For Further Information. Tektronix maintains a comprehensive, constantly expanding collection of application notes, technical briefs and other resources to help engineers working on the cutting edge of technology. Please visit www.tektronix.com.  
©
Copyright Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. Specification and price  
change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks, or registered trademarks of their respective companies.  
17 Apr 2013  
3GW-28413-1  
www.tektronix.com  

相关型号:

DPO2012B

Mixed Signal Oscilloscopes
ETC

DPO2014B

Mixed Signal Oscilloscopes
ETC

DPO2022B

Mixed Signal Oscilloscopes
ETC

DPO2024B

Mixed Signal Oscilloscopes
ETC

DPO3AERO

Mixed Signal Oscilloscopes
ETC

DPO3AUDIO

Mixed Signal Oscilloscopes
ETC

DPO3AUTO

Mixed Signal Oscilloscopes
ETC

DPO3COMP

Mixed Signal Oscilloscopes
ETC

DPO3EMBD

Mixed Signal Oscilloscopes
ETC

DPO3FLEX

Mixed Signal Oscilloscopes
ETC

DPO4000B

Mixed Signal Oscilloscopes
ETC

DPO4014B

Mixed Signal Oscilloscopes
ETC