DR48D12R [ETC]

RELAY SSR SPST-NO 12A 4-32VDC;
DR48D12R
型号: DR48D12R
厂家: ETC    ETC
描述:

RELAY SSR SPST-NO 12A 4-32VDC

文件: 总7页 (文件大小:919K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
DIN Rail Mount  
DataSheet  
AC  
DC  
SeriesOne DR Series  
Ratings of 6 & 12 Amps  
Load voltage ratings of 1-60 VDC, 1-100 VDC, 24-280 VAC and 48-600 VAC  
Fits standard 35mm DIN Rail  
LED input status indicator  
AC or DC control  
Zero Voltage (resistive loads) or Instantaneous (inductive loads) turn-on output  
UL and cUL Listed, HP Rated CE & RoHS Compliant  
UL 508 Endurance Rating for Enhanced Reliability  
UL Class I and II, Division 2, for Hazardous Locations  
PRODUCT SELECTION  
Control Voltage  
4-32 VDC  
90-140 VAC  
200-280 VAC  
18-36 VAC  
280, 6 A  
280V, 12 A  
DR24D12  
DR24B12  
DR24A12  
DR24E12  
600V, 6 A  
DR48D06  
600V, 12 A  
DR48D12  
DR48B12  
DR48A12  
DR48E12  
60V, 6 A  
DR06D06  
60V, 12 A  
DR06D12  
100V, 6 A  
DR10D06  
100V, 12 A  
DR10D12  
DR24D06  
DR24B06  
DR24A06  
DR24E06  
AVAILABLE OPTIONS  
Switching Type  
Blank: Zero Voltage Turn-On  
(AC Output Only)  
R: Instantaneous Turn-On  
(AC Output, D suffix Only)  
Operating Voltage  
06: 1-60 VDC  
10: 1-100 VDC  
24: 24-280 VAC  
48: 48-600 VAC  
Rated Load Current  
06: 6 Amps  
12: 12 Amps  
Series  
X
R
DR  
06  
D
12  
Agency Approvals  
X: ATEX II 3G Ex nA IIC T4 Gc  
approved  
Control Voltage  
D: 4-32 VDC  
A: 200-265 VAC  
B: 90-140 VAC  
E: 18-36 VAC (1)  
AC  
Output  
Only  
Required for valid part number  
For options only and not required for valid part number  
(2)  
OUTPUT SPECIFICATIONS AC Output  
Description  
Operating Voltage Range (47-63Hz) [Vrms]  
Transient Overvoltage [Vpk]  
DR24x06  
24-280  
600  
DR24x12  
24-280  
600  
DR48x06  
48-600  
1200  
DR48X12  
48-600  
1200  
Maximum Load Current, resistive [Arms] (3)  
Minimum Load Current [mArms]  
6
150  
12  
150  
6
150  
12  
150  
Maximum Off-State Leakage Current @ Rated Voltage [mArms]  
Minimum Off-State dv/dt @ Maximum Rated Voltage [V/µsec] (4)  
Maximum On-State Voltage Drop @ Rated Current [Vrms]  
Maximum Surge Current (50/60Hz, 1 cycle) [Apk]  
Maximum I²t for Fusing (50/60 Hz, 1/2 cycle) [A² sec]  
HP Rating UL 508/IEC60947 [HP (KW)] @ 240V  
HP Rating UL 508/IEC60947 [HP (KW)] @ 380V  
HP Rating UL 508/IEC60947 [HP (KW)] @ 480V  
Minimum Power Factor (at Maximum Load)  
Min/Max stranded wire  
0.1  
500  
1.3  
285/300  
400/375  
1/2 (.37)  
1 (.75)  
N/A  
0.1  
500  
1.3  
0.1  
500  
1.3  
0.1  
500  
1.3  
715/750  
2560/2330  
1 (.75)  
2 (1.5)  
3 (2.2)  
0.5  
22/14 AWG  
22/14 AWG  
3.17 oz. (90g)  
285/300  
410/375  
1/2 (.37)  
1 (1.5)  
2 (1.5)  
0.5  
22/14 AWG  
22/14 AWG  
1.76 oz. (50g)  
715/750  
2560/2330  
1 (.75)  
2 (1.5)  
3 (2.2)  
0.5  
22/14 AWG  
22/14 AWG  
3.17 oz. (90g)  
0.5  
22/14 AWG  
22/14 AWG  
1.76 oz. (50g)  
Min/Max solid wire  
Weight (Typical)  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
(2)  
OUTPUT SPECIFICATIONS DC Output  
Description  
Operating Voltage [VDC]  
DR06D06  
DR10D06  
DR06D12  
DR10D12  
1-60  
1-100  
1-60  
12  
1-100  
12  
Maximum Load Current [Adc] (3)  
6
6
Minimum Load Current [mAdc]  
2.5  
0.1  
0.6  
60  
0.1  
2.5  
0.1  
0.6  
60  
2.5  
0.1  
0.6  
100  
0.45  
22/14 AWG  
22/14 AWG  
3.17 oz (90g)  
2.5  
0.1  
0.6  
Maximum Off-State Leakage Current @ Rated Voltage [mA]  
Maximum On-State Voltage Drop @ Rated Current [Vpk]  
Maximum Surge Current (10ms) [Apk]  
On-State resistance at rated current [Ohms]  
Min/Max stranded wire  
100  
0.45  
22/14 AWG  
22/14 AWG  
3.17 oz.(90g)  
0.1  
22/14 AWG  
22/14 AWG  
1.94 oz. (55g)  
22/14 AWG  
22/14 AWG  
1.76 oz. (50g)  
Min/Max solid wire  
Weight (typical)  
(2)  
INPUT SPECIFICATIONS  
Description  
DRxxDxx  
4-32 VDC  
4.0 VDC  
1.0 VDC  
9
DRxxBxx  
90-140 Vrms  
90 Vrms  
10 Vrms  
3
DRxxAxx  
DRxxExx  
Control Voltage Range (5)  
200-265 Vrms  
200 Vrms  
40 Vrms  
2.5  
18-36 Vrms (1)  
18 Vrms  
4 Vrms  
3.5  
Minimum Turn-On Voltage  
Must Turn-Off Voltage  
Minimum Input Current for [mA] (6)  
Maximum Input Current for [mA] (6)  
Maximum Turn-on Time [msec] (7) (8)  
Maximum Turn-off Time [msec] (9)  
Min/Max stranded/solid wire  
5
11  
3.3  
8
1/2 Cycle  
1/2 Cycle  
22/16 AWG  
20 msec  
30 msec  
22/16 AWG  
20 msec  
30 msec  
22/16 AWG  
20 msec  
30 msec  
22/16 AWG  
GENERAL SPECIFICATIONS(2)  
Description  
Parameters  
4000 Vrms (10)  
109 Ohm  
10 pF  
-30 to 80 °C  
-30 to 100 °C  
Dielectric Strength, Input/Output/Base (50/60Hz)  
Minimum Insulation Resistance (@ 500 VDC)  
Maximum Capacitance, Input/Output  
Ambient Operating Temperature Range  
Ambient Storage Temperature Range  
Recommended Terminal Screw Torque Range  
4.4-7.0 in-lb (0.5-0.8Nm)  
GENERAL NOTES  
(1) E option is UL certified for AC control voltage, but it works also with 18-36 VDC input range.  
(2) All parameters at 25°C unless otherwise specified.  
(3) See Derating curves  
(4) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1  
(5) DC control includes reverse polarity protection.  
(6) Input circuitry incorporates active current limiter.  
(7) Turn-on time for DC control random turn-on versions is 0.1 msec.  
(8) Turn-on time for DC output 600µsec.  
(9) Turn-off time for DC output 300µsec.  
(10) 2500Vrms for DC output.  
Standards of Compliance  
IEC 62314  
LC A, Resistive or Slightly Inductive Load Ratings: 12 A @40°C ambient for DR24x12, 12 A @ 40°C ambient for DR48x12  
LC A, Resistive or Slightly Inductive Load Ratings: 6 A @ 40°C ambient for DR24x06, 6 A @ 40°C ambient for DR48x06  
LC B, Motor Loads Ratings: 0.75KW @ 240 VAC for DR24x06 and 2.2KW @ 480 VAC DR48x12  
LC B, Motor Loads Ratings: 0.375KW @ 240 VAC for DR24x06 and 1.5KW @ 480 VAC DR48x12  
Shock and Vibration (Applies to all part numbers)  
Vibration Resistence according to IEC 60068-2-6: 0.35mm and 0.75mm Amplitude over 10-55 Hz  
Shock Resistance according to IEC 60068-2-27: 15g/11ms  
EMC (Applies to all part numbers)  
IEC 61000-4-2: Electrostatic Discharge- Level 3  
IEC 61000-4-4: Electrically Fast Transients- Level 3  
IEC 61000-4-5: Electrical Surges- Level 3  
ANSI / ISA 12.12.01-2013  
Nonincendive Electrical Equipment for Use in Class I and II, Division 2 and Class III, Division 1 and 2 Hazadous (classified) locations  
This equipment is open-type device and is meant to be installed in an enclosure suitable for the enviroment such that the equipment is only accesible with the use of a tool  
suitable for use in Class 1, Division 2, Group A,B,C and Hazardous locations, or Nonhazardous locations only  
WARNING-Explosion Hazard- Do not disconnect equipment while the circuit is live or unless the area is known to be free of ignitable concentrations  
WARNING-Explosion Hazard- Substitution of any component may impair suitability for Class I, Division 2  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
MECHANICAL SPECIFICATIONS (2)  
EQUIVALENT CIRCUIT BLOCK DIAGRAMS/WIRING DIAGRAMS  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
THERMAL DERATE INFORMATION  
DRxxx06  
6
5
4
3
2
1
0
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
DRxxx12  
12  
10  
8
6
4
2
0
0
10  
20  
30  
40  
50  
60  
70  
80  
Ambient Temperature (ºC)  
Installed single unit, distance to adjacent components 11 mm for DRxxx06 & 18mm for DRxxx12  
Multiple units, no minimum spacing between components  
AGENCY APPROVALS  
E116949  
IND. CONT. EQ.  
4WB8  
Rev 052516  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
ACCESORIES  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
DANGER / PELIGRO / DANGER /GEFAHR / PERICOLO / 危险  
HAZARD OF  
ELECTRIC  
SHOCK,  
EXPLOSION,  
OR ARC FLASH.  
RIESGO DE  
DESCARGA  
ELECTRICA O  
EXPLOSION.  
RISQUE DE  
GEFAHR EINES  
ELEKTRISCHE  
N SCHLAGES  
ODER EINER  
EXPLOSION.  
RISCHIO DI  
SCOSSA  
ELETTRICA O  
DELL’ESPLOSIONE.  
存在电击、  
爆炸或电弧  
闪烁危险  
DESCHARGE  
ELECTRIQUE  
OU EXPLOSION  
在操作此设  
备之前请先  
关闭电源。  
Eteindre  
toutes les  
sources  
d'énergie de  
cet appareil  
avant de  
travailler  
dessus de cet  
appareil  
Spenga tutta  
l'alimentazione  
che fornisce  
questa  
apparecchiatura  
prima di lavorare  
a questa  
Desconectar  
todos los  
suministros de  
energia a este  
equipo antes  
de trabajar  
Disconnect all  
power before  
installing or  
working with  
this equipment.  
Stellen Sie  
jeglichen  
Strom ab, der  
dieses Gerät  
versorgt, bevor  
Sie an dem  
若不遵守这些说明,  
可能会导致严重的  
人身伤害甚至死亡。  
con este equipo.  
Verify all  
connections  
and replace all  
covers before  
turning on  
Gerät Arbeiten  
durchführen  
apparecchiatura  
Verificar todas  
las conexiones  
y colocar todas  
las tapas antes  
de energizer  
Verificare tutti  
i collegamenti  
e sostituire  
tutte le coperture  
prima  
Vor dem  
Drehen auf  
Energie alle  
Anschlüsse  
überprüfen  
und alle  
Vérifier tous  
connections, et  
remettre tous  
couverts en  
olace avant de  
mettre sous  
power.  
el equipo.  
Failure to follow  
these  
instructions will  
result in death  
or serious injury.  
dell’accensione  
El  
Abdeckungen  
ersetzen.  
L'omissione di  
queste istruzioni  
provocherà la  
morte o  
incumplimiento  
de estas  
instrucciones  
puede provocar  
la muerte o  
lesiones serias.  
De non-suivi de  
ces instructions  
provoquera la  
mort ou des  
lésions sérieuses  
sérieuses.  
Unterlassung  
dieser  
Anweisungen  
können zum  
Tode oder zu  
schweren  
lesioni serie  
Verletzungen  
führen.  
WARNING / AVERTISSEMENT / WARNUNG /ADVERTENCIA / AVVERTENZA / 警告  
RISQUE DE DOMMAGE MATERIEL ET DE  
SURCHAUFFE DU BOITIER  
GEFAHR VON MATERIALSCHÄDEN UND  
GEHÄUSEERHITZUNG  
RISK OF MATERIAL DAMAGE AND HOT  
ENCLOSURE  
Les panneaux latéraux du produit peuvent être  
chauds. Laisser le produit refroidir avant de le  
toucher.  
Respecter les consignes de montage, et  
notamment les couples de serrage.  
Ne pas laisser pénétrer de liquide ni de corps  
étrangers à l'intérieur du produit.  
Die Seitenwände können heiß sein. Lassen Sie  
das Produkt abkühlen, bevor Sie es berühren.  
Beachten Sie die Montageanweisungen,  
Führen Sie keine Flüssigkeiten oder  
The product's side panels may be hot, allow  
the product to cool before touching.  
Follow proper mounting instructions including  
torque values.  
Do not allow liquids or foreign objects to enter  
this product.  
Fremdkörper in das Produkt ein.  
Le non-respect de cette directive peut entraîner,  
des lésions corporelles graves ou des  
dommages matériels.  
Die Nichtbeachtung dieser Anweisung kann  
Körperverletzung oder Materialschäden  
zur Folge haben.  
Failure to follow these instructions can result in  
serious injury, or equipment damage.  
RIESGO DE DAÑOS MATERIALES Y DE  
SOBRECALENTAMIENTO DE LA UNIDAD  
材料损坏和高温外壳的危险性  
RISCHIO DI DANNI MATERIALI E D'INVOLUCRO  
CALDO  
 产品的一侧面板可能很热,在其冷却前请  
 不要触碰。  
 遵照正确的安装说明,包括扭矩值。  
 请勿让液体及其他异物进入本产品。  
Los paneles laterales del producto pueden  
estar calientes. Esperar que el producto se  
enfríe antes de tocarlo.  
Respetar las instrucciones de montaje, y en  
particular los pares de apretado.  
I pannelli laterali dell'apparecchio possono  
scottare; lasciar quindi raffreddare il prodotto  
prima di toccarlo.  
Seguire le istruzioni di montaggio corrette.  
Non far entrare liquidi o oggetti estranei in questo  
apparecchio.  
No dejar que penetren líquidos o cuerpos  
extraños en el producto.  
La mancata osservanza di questa precauzione può  
causare gravi rischi per l'incolumità personale o  
danni alle apparecchiature.  
如不能正确执行这些操作说明,  
极有可能造成严重人体伤害或者设备的损坏。  
Si no se respetan estas precauciones pueden  
producirse graves lesiones, daños materiales.  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  
DIN Rail Mount  
DataSheet  
ANNEX - ENVIROMENTAL INFORMATION  
The environmental information disclosed in this annex including the EIP Pollution logo are in compliance with People’s Republic of China  
Electronic Industry Standard SJ/T11364 – 2006, Marking for Control of Pollution Caused by Electronic Information Products.  
Part  
Name  
Toxic or hazardous Substance and Elements  
Lead  
(Pb)  
Mercury  
(Hg)  
Cadmium  
(Cd)  
Hexavalent  
Chromium  
(Cr (VI))  
Polybrominated  
biphenyls  
(PBB)  
Polybrominated  
diphenyl ethers  
(PBDE)  
Semiconductor die  
Solder  
附件 - 环保信息  
此附件所标示的包括电子信息产品污染图标的环保信息符合中华人民共和国电子行业标准 SJ/T11364 - 2006,  
电子信息产品污染控制标识要求。  
部件  
名称  
有毒有害物质或元素  
(Pb)  
(Hg)  
(Cd)  
六价铬  
(Cr (VI))  
多溴联苯  
(PBB)  
多溴二苯醚  
(PBDE)  
半导体芯片  
焊接点  
50  
Do not forget to visit us at: www.crydom.com  
Copyright © 2017 Crydom Inc. Specifications subject to change without notice.  

相关型号:

DR48D12X

Ratings of 6 & 12 Amps
CRYDOM

DR48D12XR

Trigger Output SSR,
CRYDOM

DR48D15/100G

Analog IC
ETC

DR48D1XR

RELAY SSR 48-600 V
ETC

DR48D25

Single Output to 30A 510 Vac DIN-Rail Solid-State Relay
TELEDYNE

DR48D25-21

Single Output to 30A 510 Vac DIN-Rail Solid-State Relay
TELEDYNE

DR48D30

Single Output to 30A 510 Vac DIN-Rail Solid-State Relay
TELEDYNE

DR48E03XR

DIN Rail Mount
CRYDOM

DR48E06XR

DIN Rail Mount
CRYDOM

DR48E12

Ratings of 6 & 12 Amps
CRYDOM

DR48E12R

Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT PACKAGE-4
CRYDOM

DR48E12X

Trigger Output SSR,
CRYDOM