EFRQ600240R40-026 [ETC]

;
EFRQ600240R40-026
型号: EFRQ600240R40-026
厂家: ETC    ETC
描述:

文件: 总2页 (文件大小:213K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Home  
NEW! EFRQ Series  
TELEDYNE RELAYS  
QUAD SCR OUTPUTS TO 55 AMPS PER OUTPUT, 1200 VOLTS  
Industrial Solid State Products  
PART NUMBERS  
Package &  
Chip Type  
Max Blocking Input Type  
Voltage (piv)/  
Line Rating  
Output  
Current  
Amps  
Options  
EFRQ-SCR 1200480  
D-DC Input  
Zero Cross  
Switching  
R-DC Input,  
Random  
25  
40  
55  
See Table  
Below and  
Page 58  
600240  
FEATURES/BENEFITS  
Four independently controlled solid state  
relays in a single package.  
Turn-On  
Screw type power terminals in a high  
temperature plastic housing for mechanical  
ruggedness.  
Options (Add Suffix to Part Number) - See Page 58 for full description  
Constant Current Input minimizes source  
current requirement (standard on D input  
only)  
-012 EZ MountTM  
-026 Non-Floating Output Terminals  
Exposed ceramic baseplate for reduced  
thermal resistance and best thermal  
performance.  
Part Number Example: EFRQ120480D55  
Constructed using Teledyne’s unique  
PowerthermTM process. This process yields  
superior thermal impedance and power  
cycling capabilities through reduced thermal  
interconnections, allowing for cooler, more  
reliable operation.  
MECHANICAL SPECIFICATION  
.739  
(18.77)  
rol In 3-32V  
.250 TYP.  
(6.35)  
M5 SCREW /  
NUT  
.160  
(4.06)  
.160 DIA.  
(4.06)  
The logic drive circuitry section uses the  
latest in reliable surface mount technology.  
(+COM) (1)— (2)— (3)— (4)—  
A1  
B1  
.825  
(20.96)  
TELEDYNE RELAYS  
Certifications:  
2.50  
POWERTHERMTM  
1.20  
(30.5)  
(63.5)  
-
-
UL and ULC Recognized File #E128555  
CE # EN60947-1  
L1  
L2  
.825  
(20.96)  
EFRQ Series  
A2  
B2  
.650  
(16.51)  
.420  
(10.67)  
TYPICAL APPLICATIONS  
On/Off controls of medium power AC  
2.500  
(63.5)  
.758  
(19.3)  
equipment.  
3.60  
(91.44)  
.200  
(5.08)  
Interfacing of microprocessor controls to AC  
loads - lights, motors, heaters, valves,  
solenoids etc.  
4.00  
(101.6)  
Electromechanical line relay replacement.  
Mercury displacement relay replacement.  
Industrial and Process Controls.  
BLOCK DIAGRAM  
Programmable Controller interface.  
(1)  
A1  
Robotics motor position and speed controls.  
Light dimmers; Transformer tap switch.  
OPTO  
ISOLATED  
CONTROL  
DETECTION/  
CONTROL  
CIRCUIT  
AC OUTPUT A  
L1  
GENERAL DESCRIPTION  
(2)  
The EFRQ series 4-pole AC Solid State Relays are  
designed to save space while providing independent  
control of large amounts of power in four separate  
circuits. Optical isolation ensures complete protection  
of each relay’s circuit control elements from load  
transients in each load circuit. Teledyne’s advanced  
design featuring the PowerthermTM process offers  
users superior thermal management resulting in  
excellent performance, quality and reliability.  
OPTO  
ISOLATED  
CONTROL  
DETECTION/  
CONTROL  
CIRCUIT  
AC OUTPUT B  
A2  
B2  
(3)  
OPTO  
ISOLATED  
CONTROL  
DETECTION/  
CONTROL  
CIRCUIT  
AC OUTPUT C  
L2  
(4)  
OPTO  
ISOLATED  
CONTROL  
DETECTION/  
CONTROL  
CIRCUIT  
AC OUTPUT D  
(+ COM)  
B1  
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE.  
Updated 9/24/99  
page 32  
Home  
TELEDYNE RELAYS  
NEW! EFRQ Series  
Industrial Solid State Products  
QUAD SCR OUTPUTS TO 55 AMPS PER OUTPUT, 1200 VOLTS  
ELECTRICAL SPECIFICATIONS  
INPUT (CONTROL) SPECIFICATIONS  
OUTPUT (LOAD) SPECIFICATIONS (Contd)  
Parameter  
Input Type  
Min  
Max  
32  
Units  
Parameter  
Output Current Min Max  
Units  
D
R
3
Control Voltage Range  
Vdc  
Output Current Rating  
Per Output  
25  
40  
55  
0.05 25  
0.05 40  
0.05 55  
4
26  
A
Input Current  
D,R(@5Vdc)  
15  
mA  
(Load Current @85 °C)  
Must Turn-Off Voltage  
D,R  
1
Vdc  
Reverse Voltage Protection  
Turn-Off Current  
D,R  
D,R  
-32  
Vdc  
Surge Current Rating  
See Fig 1 (Non-  
25  
40  
55  
250  
400  
600  
A
0.25  
mA(DC)  
Repetitive 16.7 mS)  
OUTPUT (LOAD) SPECIFICATION  
Parameter  
Voltage Code Min  
Max  
Units  
Thermal Resistance  
Junction to Case (JC)  
Per Contact  
25  
40  
55  
.40  
0.35 °C/W  
600240  
24  
48  
280  
530  
Load Voltage Rating  
Vac  
0.35  
1200480  
Frequency Range (Note 2)  
47  
400  
Hz  
600240  
1200480  
600  
Over Voltage Range  
VPeak  
FIGURE 1 Max Non-Repetitive Surge Current  
1200  
On-State Voltage Drop SCR Output  
@ Max Rate Current  
1.4  
V
Turn-On Time  
D
R
8.3  
ms  
ms  
0.02  
Turn-Off Time  
8.3  
0.5  
ms  
Leakage Current (Off-State)  
mA  
250  
@25 °C  
dV/dt (Typical)  
500  
V/µs  
Isolation (All Terminals  
To Heatsink) = VRMS  
For 1 Min With Unit  
1
10  
100  
Mounted Properly  
4000  
125  
1.0  
V
Number of Equal Amplitude Current Pulses at 60Hz  
Operating Temperature  
Power Factor Range  
-40  
0.5  
°C  
NOTES:  
1.) Where overvoltage transient spikes are present,  
suppression may be required. An MOV suppressor and/or  
a snubber circuit across the AC terminals of the module  
will provide additional transient immunity.  
2.) For 400 Hz inductive load, contact factory.  
3.) Curve for 25 amp output shown. Contact factory for other  
outputs.  
Updated 9/24/99  
Industrial Solid State Products 800-436-8766 • www.teledynerelays.com  
page 33  

相关型号:

EFRRHB25K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRHB40K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRQB25K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRQB40K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRSB25K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRSB40K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRUB25K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRUB40K5

Ultrasonic Ceramic Sensors
PANASONIC

EFRRXXXX

Ultrasonic Ceramic Sensors
PANASONIC

EFRTHB25K5

Ultrasonic Ceramic Sensors
PANASONIC