EHN.1F.308.XLM [ETC]
CONN RCPT FMALE 8POS GOLD CRIMP;型号: | EHN.1F.308.XLM |
厂家: | ETC |
描述: | CONN RCPT FMALE 8POS GOLD CRIMP 连接器 |
文件: | 总48页 (文件大小:7533K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
COMPACT MULTIPOLE
CONNECTORS
No reproduction or use without express permission of editorial or pictorial content, in any manner.
LEMO reserve the right at all times to modify and improve specifications without any notification.
®
®
Table of Contents
General production programme....................................................................................................page 2
Main characteristics and types...............................................................................................................2
Series and types ......................................................................................................................................3
LEMO’s push-pull self-latching connection system.............................................................................4
F series production program ..................................................................................................................4
General characteristics ...........................................................................................................................5
Selection of shell materials, degrees of protection (IP code) .............................................................5
Selection of contact types (crimp, print, fibre optic)............................................................................6
F Series ......................................................
Interconnections.........................................................................................................................................8
Part numbering system..............................................................................................................................9
Part section showing internal components ....................................................................................................9
Technical characteristics ...........................................................................................................................10
Metal housing models..............................................................................................................................11
Watertight PCB models............................................................................................................................15
Models for Fibre Optic..............................................................................................................................16
Alignment key...........................................................................................................................................17
Insert configuration ..................................................................................................................................18
Housings, contacts, cable fixing...............................................................................................................20
Variant......................................................................................................................................................21
LEMO F1 ECU systems connectors ........................................................................................................22
Spare parts...............................................
Crimp contacts .........................................................................................................................................24
F7 fibre optic contacts..............................................................................................................................25
Locking washers, hexagonal nuts, notched nuts .....................................................................................25
Conical nuts .............................................................................................................................................26
Accessories..............................................
Tooling........................................................
Caps.........................................................................................................................................................28
Heatshrink boot, insulating washers ........................................................................................................29
Spanners, taps, manual and pneumatic crimping tools...........................................................................30
Positioners, extractor for crimp contact....................................................................................................31
Banding tool, retention testing tool ..........................................................................................................32
Fibre Optic Tooling ...............................
Complete workstation for F7 fibre optic contact.......................................................................................32
Crimping tool, epoxy curing oven, polishing tool .....................................................................................32
Fibre inspection microscope, microscope adaptor, F7 contact alignment device tool.............................33
Panel Cut-Outs........................................
PCB Drilling Pattern.............................
Mounting nut torque .................................................................................................................................33
Fixed socket with straight print contact....................................................................................................34
Fixed socket with elbow print contact ......................................................................................................35
Technical Characteristics..................
Outer shell................................................................................................................................................37
Insulator ...................................................................................................................................................37
Electrical contact......................................................................................................................................38
Test voltage ..............................................................................................................................................39
Rated current ...........................................................................................................................................40
Assembly instructions ..............................................................................................................................41
Technical tables........................................................................................................................................42
Product safety notice................................................................................................................................44
1
www.lemo.com
®
®
General Production Programme
Connectors
Unipole from 2 to 150 Amps
Coaxial 50 and 75 Ω
Patch Panels
Adaptors
All audio-video and HDTV applications
Coaxial 50 Ω (NIM-CAMAC)
Coaxial 50 Ω for frequency → 12 GHz
Multicoaxial 50 and 75 Ω
● Multipole from 2 to 68 contacts
Multipole up to 106 contacts
High Voltage 3, 5, 8, 10, 15, 30 and 50 kV cc
Multi High Voltage 3, 5, and 10 kV cc
Triaxial 50 and 75 Ω
For BNC, C, UHF, N, CINCH, GEN-RADIO connectors
For TNC, SMA connectors
Accessories
Insulator for crimp contacts
● Crimp contacts
Coaxial contacts
Triaxial contacts
● Fibre optic contacts
Fluidic contactss
● Caps
Quadrax
Mixed: High Voltage (HV) + Low Voltage (LV)
Mixed: Coax + LV and Triax + LV
Thermocouple and multithermocouple
Fibre optic singlemode and multimode
● Multi Fibre optic
Bend relief
● Heatshrink boot
● Washers
● Nuts
● Mixed: fibre optic + LV
Mixed: fibre optic + HV + LV
Fluidic and Multifluidic
Tooling
Assembly tool
● Crimping tools
● Positioners
Mixed: fluidic + LV
● Extractors
Subminiature
● Miniature
● Banding tool
● Fibre optic termination workstation and tools
● Sockets for printed circuit board
Remote handling shell
On request
Connectors with special housing
Special mixed configuration
Custom design
● Watertight socket
Hermaphroditic shell
Rectangular connectors
Assembly onto cable
Sealed (pressure and/or vacuum) socket
Plastic shell
● Connectors, accessories and tools found in this catalogue.
● With aluminium outer shell
With stainless steel outer shell
With microswitch
Main Characteristics and Types
Keyed
Compact
Standard
Watertight
Keyed
Hermaphroditic
Rectangular
Screw
Series
Watertight
keyed
01 / 00 (unipole)
00 (NIM-CAMAC)
05 / R0 / 1D
0S to 6S
0E to 6E
3T
00 (multipole)
0B to 5B
2G / 5G
0K to 5K
2N to 5N
FF to 5F
SH / MH
RR / 0R / 1R
03
0V to 5V
0W to 5W
2U to 5U
0M-1M-2M
4M
0A / 4A / 2C
1Y-3Y-6Y
Latching
Key
Push-Pull
Screw
Hermaphroditic
shell
Key (G)
or other key-way code
Key (N) or other
key-way code
Key or
stepped insert
Stepped insert
Key G or A
Plastic
Metal or plastic
Metal
Metal or plastic
Metal
Metal
Shell
Stepped insert
or cylindrical
Insert
Stepped insert or cylindrical
Solder or print
Cylindrical
Stepped insert
Rectangular
Crimp or print
Contact
termination
Solder,
crimp or print
Solder
crimp or print
Solder, crimp or print
Crimp or print
Contact
type
Coaxial, triaxial, unipole, multipole
HV, quadrax, fluidic, thermocouple
Multipole, fibre optic,
HV, fluidic, thermocouple
Multipole, HV,
coaxial, fluidic
Multipole,
coaxial, triaxial
Multipole, fibre optic
LV + coax,
LV + triax,
LV + FO,
LV + coax,
LV + HV,
LV + fluidic
Mixed
config.
LV + coax, LV + triax, LV + HV,
LV + FO, LV + fluidic
LV + coax, LV + HV
LV + FO
LV + fluidic
2
www.lemo.com
®
®
Series and Types
Types
Series
●
●
01
00
●
●
●
●
05
●
●
●
●
●
●
●
●
R0
0A
0S
1S
2S
3S
4S
5S
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Standard
●
●
●
●
●
●
●
●
●
●
●
●
●
6S
●
1D
●
●
2C
●
4A
●
1Y-3Y-6Y
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0E
1E
2E
3E
4E
5E
6E
3T
4M
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Watertight
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
00
0B
1B
XB
2B
3B
4B
5B
2G
5G
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Keyed
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
0K
1K
2K
3K
4K
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Keyed
watertight
●
●
●
●
5K
●
●
●
●
●
●
●
2N to 5N
●
●
●
●
●
●
●
●
●
FF
0F
1F
2F
3F
4F
LF
5F
●
●
●
●
Compact
keyed
Hermaphroditic
Rectangular
SH-MH
●
●
●
RR
0R
1R
●
●
●
●
●
●
●
●
●
●
●
●
●
03
●
●
●
●
●
●
●
0V to 5V
0W to 5W
2U to 5U
0M-1M-2M
Screw
●
●
●
●
●
●
●
●
●
●
Note: ● = included in this catalogue, ● = available but not included in this catalogue.
3
www.lemo.com
®
®
LEMO’s Push-Pull Self-Latching Connection System
This self-latching system is renowned worldwide for its easy and quick mating and unmating features. It provides absolute
security against vibration, shock or pull on the cable, and facilitates operation in a very limited space.
The LEMO self-latching system allows the connector
to be mated by simply pushing the plug axially into
the socket.
Once firmly latched, connection cannot be broken
by pulling on the cable or any other component part
other than the outer release sleeve.
When required, the connector is disengaged by a
single axial pull on the outer release sleeve.
This first disengages the latches and then withdraws
the plug from the socket.
F Series Production Programme
Series
FF
0F
1F
2F
3F
4F
LF
5F
min.
max.
2.2
9
3.8
11
3.8
13
3.8
16
3.8
18
5.3
25
6.3
27
7.4
34
Cable Ø
range (mm)
Number of
LV contacts
4, 8, 10,
12, 19
3, 4 2, 3, 4, 5 3, 5, 7, 8
22, 30
–
40
–
68
–
50, 55, 64, 66
–
2
multi
Nr of FO
contacts 1)
–
–
–
mixed
2 + 4 LV
Note: 1) For cable ranging from 3.6 to 6.5 mm in diameter.
4
www.lemo.com
®
®
General Characteristics
Selection of shell materials
Aluminium alloy
Brass
The aluminium alloy outer shells find numerous applications
where light weight is a predominant factor; such as in the
aeronautics and space industries, and for portable and
mobile equipment.
Shells are made of high mechanical strength alloy (Alu-
minium alloy). Connector shells are protected by a conduc-
tive anthracite grey coloured nickel finish.
As a standard latch sleeve are made of special bronze or
brass, this material offer excellent performances for most of
the applications.
For very demanding vibrating situation we recommand the
use of special latch sleeve in beryllium copper alloy. These
parts have an electrolytic nickel plating.
As a standard gaskets are made of fluororubber FPM/FKM.
This material has excellent resistance to hydrocarbons.
The brass outer shells have a chrome nickel-plated sur-
face which ensures very good protection against industrial
atmosphere, salt air and most corrosive agents.
In case of brass shell standard latch sleeves are made of
special bronze or brass.
Here standard gaskets are made of silicone rubber
MQ/MVQ. This material has excellent weather resistance
and a wide temperature range.
Other metallic components
In general, most metallic components are manufactured in
brass. However, bronze or beryllium copper are used
where good elasticity is required (for example: earthing
crown). Depending on the application, these parts have
electrolytic nickel plating.
Sealing resin
An epoxy resin is used to seal both watertight and
vacuumtight socket and coupler models.
Degrees of protection (IP code)
IEC 60529 outlines an international classification system
for the sealing effectiveness of enclosures of electrical
equipment against the intrusion into the equipment of
foreign bodies (i.e., tools, dust, fingers) and moisture. This
classification system utilizes the letters «IP» (Ingress
Protection) followed by two digits.
Example: IP 64 = IP
6
4
IP letter code
1st digit
2nd digit
Degrees of protection - First digit
Degrees of protection - Second digit
The first digit of the IP code indicates the degree that per-
sons are protected against contact with moving parts and
the degree that equipment is protected against solid
foreign bodies intruding into an enclosure.
Second digit indicates the degree of protection of the
equipment inside the enclosure against the harmful entry
of various forms of moisture (e.g. dripping, spraying, sub-
mersion, etc.)
0 No special protection
0 No special protection
1 Protection from a large part of the body such as hand
or from solid objects greater than 50 mm in diameter
2 Protection against objects not greater than 80 mm in
length and 12 mm in diameter
1 Protection from vertically dripping water
2 Protection from dripping water when tilted up to 15°
3 Protection from sprayed water
4 Protection from splashed water
3 Protection from entry by tools, wires, etc., with a dia-
meter or thickness greater than 2.5 mm
4 Protection from entry by solid objects with a diameter or
thickness greater than 1.0 mm
5 Protection from water projected from a nozzle
6 Protection against heavy seas, or powerful jets of water
7 Protection against temporary immersion
8 Protection against complete continuous submersion in
water
5 Protection from the amount of dust that would interfere
with the operation of the equipment
6 Dust-tight
UL Recognition
LEMO connectors are recognized by the Underwriters Laboratories (UL). The approval of the complete system (LEMO
connector, cable and your equipment) will be easier because LEMO connectors are recognized.
RoHS
LEMO connector specifications conforms the requirements of the RoHS directive (2011/65/EU) of the European
Parliament and the latest amendments.This directive specifies the restrictions of the use of hazardous substances in elec-
trical and electronic equipment marketed in Europe.
5
www.lemo.com
®
®
Selection of contact types
Crimp contacts
The crimp contacts are designed to be crimped with the
standard four indent method according to MIL-C-22520F,
class 1, type 1.
Contacts are provided in two forms: with a standard crimp
barrel for large conductors (see fig. 1), or with a reduced
crimp barrel for smaller conductors (see fig. 2).
Contact
Conductor stranded
AWG stranded
Section (mm2)
Fig. 1
ø A
ø A
ø C
Fr
(N)
ø A ø C Form
(mm) (mm) per fig.
min.
max.
min.
max.
0.5 0.42
0.7 0.80
0.9 1.10
1.3 1.40
1
1
1
1
32
26
24
20
281)
221)
20
0.035
0.140
0.250
0.500
0.09
0.34
0.50
1.00
12
22
30
40
ø C
18
Contact
Conductor stranded
Fig. 2
ø A
ø A
ø C
ø C
Fr
(N)
AWG stranded
Section (mm2)
ø A ø C Form
(mm) (mm) per fig.
min.
max.
min.
max.
0.7 0.45
2
2
2
2
32
26
32
24
28
221)
0.035
0.140
0.035
0.250
0.09
0.34
0.09
0.50
22
30
40
0.80
0.9
0.45
28
1.3 1.10
20
Note: Fr = mean contact retention force in the insulator (according to IEC
60512-8 test 15a).
A detailed range of conductor dimensions that can be
crimped into our contacts is given on the table at right. See
also the section on tooling (pages 30 to 33).
1)
Note:
for a given AWG, the diameter of some stranded conductor
designs is larger than the solder cup diameter. Make sure that the maxi-
mum conductor diameter is smaller than ø C.
Print contacts
Print contacts are available in straight or elbow versions
for certain connector types. Connection is possible by sol-
dering on flexible or rigid printed circuit boards.
Straight print contacts are gold-plated which guarantees
optimum soldering, even after longterm storage.
Print elbow contacts include a tinned copper wire crimped
into a contact.
L dimensions and C ø are detailed in the section on model
description (elbow: L = 2 mm).
straight
elbow
L
ø A
ø A
ø C
ø C
ø A
L
L
ø C
Fibre Optic contacts
The new miniature F7 fibre optic contact is available for use
with single-mode or multi-mode fibres of the following
sizes; 9/125, 50/125 and 62.5/125 microns.
Contacts are designed with the IEC standard 1.25 mm dia-
meter ceramic ferrules. After mounting on the cable, the
contact is very easily installed in the connector insulator,
the particular shape of the contact body retains it in the
insulator. The alignment tube can be easily removed in
order to clean the fibre end face.
Female contact
4
1
3
5
3
1
4
2
2
Male contact
1
2
3
4
5
body with holder
ferrule with holder
spring
body with holder
ferrule with holder
spring
1
2
3
4
crimp ferrule
alignment tube
with support
crimp ferrule
6
www.lemo.com
®
®
F Series
The F series connectors have been specially developed to meet the most demanding requirements in terms of dimen-
sions, weight and watertightness. Our manufacturing programme includes now 8 series. This series provides customers
with many features and benefits including:
– push-pull self-latching system for safe connection
– sealed to IP67 for environmental protection when mated according to IEC 60529
– compact scoop-proof design and use of aluminium alloy
– high shock and vibration resistance
– multipole types with 2 to 68 contacts or multifibre optic or mixed FO + LV in 2F series
– crimp or print contacts (straight or elbow)
– keys ensuring ease of blind mating
– colour coded key options for system security.
The F series connectors are available in 3 different materials:
– for high shock and vibration resistance, LEMO recommends using Y code material (with beryllium copper latch sleeve).
– for environmental resistance and latching cycle endurance, LEMO recommends using the C code material
(brass outershell).
– for lightweight and latching cycle endurance, LEMO recommends using X code material (aluminium shell).
– for lightweight and salt spray corrosion resistance, LEMO recommends using I code material (aluminium shell).
Each series includes several models of plugs and sockets available in contact configurations adapted to all round cables,
including up to 68 conductors, and a maximum diameter of 34 mm. Since LEMO connectors are perfectly screened and
designed to guarantee very low resistance to shell electrical continuity, they are particularly adapted to applications
where electromagnetic compatibility (EMC) is important. A large number of accessories as well as tooling for cable
assembly are available.
Metal housing models (page 11)
Straight plugs
Fixed sockets
Fixed sockets
Free socket
EC
FG
ED
EG
PE
PH
FN
EC
EE
PB
EH
EF
Models for fibre optic (page 16)
Watertight models (page 15)
Fixed sockets
Straight plug
Fixed socket
FG
EH
HE
HE
8
www.lemo.com
®
®
Part Numbering System
5)
T = f.o. cable adapter and ø :
Z = collet nut for bend relief
(page 20)
T 66 Z
or
FG N 0F
305
305
305
Y
X
X
L
L
L
C
M
N
Plug
.
.
.
.
.
.
.
Variant: (page 21)
F = reduced unlatching force
1)
2)
S = o-ring & gasket in silicone
PH N 0F
Free socket
.
Fixed socket HE N 0F
P
.
Model: (page 11)
Variant 3): (page 21)
Contact 4): (page 20)
Insulator: L = PEEK
Housing: (page 20)
Alignment key: (page 17)
Series: (page 11)
Insert configuration: (page 18)
Part Number Example
Straight plug:
FGN.0F.305.YLC = straight plug with key (N), 0F series, multipole type with 5 contacts, outer shell in anthracite nickel-plated
aluminium alloy, beryllium copper latch sleeve, PEEK insulator, male crimp contacts.
Free socket:
PHN.0F.305.XLM = free socket with key (N), 0F series, multipole type with 5 contacts, outer shell in anthracite nickel-plated
aluminium alloy, PEEK insulator, female crimp contacts.
Fixed socket:
HEN.0F.305.XLNP = fixed socket, nut fixing, with key (N), 0F series, multipole type with 5 contacts, outer shell in anthracite
nickel-plated aluminium alloy, PEEK insulator, female print contacts, watertight.
Note: 1) for straight plug only. 2) with shell material code X or Y. 3) potting for HE● only. 4) HE● available only with print contacts (straight or elbow).
5) connectors for fibre-optic are delivered without the fibre optic contacts, they must be ordered separately (see page 25).
Part Section Showing Internal Components
Straight socket
Straight plug
5
3
2
4
1
6
1
4
5
3
5
2
6
1
2
3
4
5
6
1
2
3
4
5
6
outer shell
earthing crown
insulator
outer shell
latch sleeve
insulator
female contact
rear seal
male contact
gasket
front nut
rear seal
www.lemo.com
9
®
®
Technical Characteristics
Materials and Treatments
Surface treatment (μm)
nickel
Shell
material code
Component
Material (Standard)
Notes
chrome
gold
I
X
Y
C
I
X
Brass (UNS C 38500)
0.3
–
–
14
–
–
5
–
–
–
–
Outer shell
Conical nut
1)4)5)6)
Aluminium alloy (AA 6262A or AA 6023)
Brass (UNS C 38500)
0.3
2)
3)
Aluminium alloy (AA 6262A or AA 6023)
Brass (UNS C 38500)
anodized various colour
0.3
–
–
14
3
–
5
3
3
3
3
3
–
–
–
–
–
–
–
Notched nut
1)3)6)
Aluminium alloy (AA 6262A or AA 6023)
Bronze (UNS C 54400) or special brass
Special bronze/brass
–
Earthing crown
Latch sleeve
–
3
–
3
Beryllium Copper (UNS C 17300)
Bronze (UNS C 52100)
–
3
Locking washer
Hexagonal nut
–
3
Brass (UNS C 38500)
anodized natural
Aluminium alloy (AA 6262A or AA 6023)
Brass (UNS C 38500)
–
–
–
0.5
–
–
3
–
–
–
1.0
1.5
Other metallic components
Male crimp contact
Female crimp contact
Clips
Brass (UNS C 34500)
Bronze (UNS C 54400)
without treatment
Cu-Be or special steel
–
–
–
–
–
PEEK
Insulator
FPM/FKM (Viton®)
O-ring and gaskets
7)
Silicone MQ/MVQ
Epoxy (Araldite® or Stycast®)
Fluorosilicone
Sealing resin
Cable rear seal
Notes: standards for surface treatment are as follows: chrome-plated SAE AMS 2460; nickel-plated SAE AMS QQ N 290 or MIL DTL 32119; gold-plated
ISO 27874. 1) anthracite colour. 2) the colour match the colour code of the key (see page 17). 3) for the FF series only. 4) FF series available only with material
TM
code Y. 5) LF and 5F series available only with material code X. 6) Nickel Teflon® - NiCorAl treatment (500 hours salt spray corrosion resistant). 7) Silicone
gasket are available as a variant for code material X and Y.
Mechanical and Climatical
Characteristics
Value
Standard
Series / Shell material
Endurance
1000 cycles
IEC 60512-5 test 9a
IEC 60512-5 test 9a
IEC 60512-5 test 9a
All; code X
Endurance
300 cycles (FF and 0F); 500 cycles (1F to 3F)
All; code Y
Endurance
Humidity
5000 cycles
up to 95% at 60° C
-15° C, +200° C
-55° C, +200° C
10-2000 Hz, 15 g
pass
All; code C
All
Operating temperature
Operating temperature
Vibration resistance
Vibration (Gunfire test)
Vibration (Gunfire test)
Vibration (ECU profile)
Shock resistance
All; code X or Y
All; code C
IEC 60512-4 test 6d
MIL-standard 810 F
MIL-standard 810 F
See diagram below
IEC 60512-4 test 6c
IEC 60512-6 test 11f
IEC 60512-6 test 11f
IEC 60512-6 test 11f
All
4F, LF and 5F; all materials
FF, 0F, 1F, 2F, 3F; code Y
FF, 0F, 1F, 2F; code Y
All
pass
pass
100 g, 6 ms
96 h
Salt spray corrosion test
Salt spray corrosion test
Salt spray corrosion test
Protection index (mated)
Climatical category
Climatical category
All; code X or Y
All; code I
500 h
1000 h
All; code C
All
IP67 (select HE● model only for device protection) IEC 60529
15/200/21
50/175/21
IEC 60068-1
IEC 60068-1
All; code X or Y
All; code C
Electrical
Vibration (ECU profile)
Insulation resistance
Shell electrical continuity
IEC 60512-2 test 2f
10
IEC 60512-2 test 3a
Value
Ω
Value
mΩ
1
1)
new
FF-0F 1F 2F-3F 4F
LF
1.5
5F
1.5
> 1012
> 1010
5.0
3.0
2.5
2.0
0.1
0.01
0.001
Contact resistance 2)
IEC 60512-2 test 2a
Value
Notes:
1) after humidity test: 21 days at 95% RH according
to IEC 60068-2.
10
20
200
400
435
2000
0.5
0.7
0.9
1.3 ø A (mm)
2) after 5000 mating cycles and the salt spray test
according to IEC 60512-6 test 11 f.
Frequency (Hz)
≤ 8.7 ≤ 6.1 ≤ 4.8 ≤ 3.6
mΩ
10
www.lemo.com
®
®
Models
FGl Straight plug, key (N) or keys (P, S, T, W and X)
Reference
Dimensions (mm)
Model
Series
A
B
L
M
X
FGl
FGl
FGl
FGl
FGl
FGW
FGX
FGW
FGX
FGl
FF
0F
1F
2F
3F
4F
4F
LF
LF
5F
8.5 6.3 21.6 13.8 5.7
12.0 9.0 27.5 17.8 8.0
14.0 10.7 27.8 17.9 8.0
17.0 14.0 27.8 17.9 8.0
19.0 16.0 27.8 17.9 8.0
26.0 21.2 30.3 20.4 8.0
26.0 21.2 30.7 20.4 8.0
29.0 24.2 34.7 20.4 8.0
29.0 24.2 34.7 20.4 8.0
36.1 30.2 36.7 20.4 8.0
L
~M
X
Note: this plug can also be supplied with a reduced unlatching force
(see page 9).
FNl Straight plug, key (N) or keys (P and S)
and lanyard release
Reference
Dimensions (mm)
Model
Series
A
B
C
L
M
N
X
FNl
FNl
FNl
FNl
FNl
0F
1F
2F
3F
4F
12.0 9.0 18.0 27.5 17.8 140 8.0
14.0 10.7 20.0 27.8 17.9 140 8.0
17.0 14.0 23.0 27.8 17.9 160 8.0
19.0 16.0 25.0 27.8 17.9 190 8.0
26.0 21.2 32.0 30.3 20.4 230 8.1
L
~M
X
Note: cable material: stainless steel with protective sheath
EGl Fixed socket, nut fixing, key (N)
or keys (P, S and T), IP50
N
Reference
Dimensions (mm)
M
S 3
Model
Series
A
B
e
E
M
N
S1 S3
EGl
EGl
EGl
EGN
EGP
EGS
EGT
0F
1F
2F
3F
3F
3F
3F
10 12.4 M9x0.6 7.0 1.2 19.0 8.2 11
14 15.8 M12x1.0 6.5 1.5 19.0 10.5 14
18 19.2 M15x1.0 6.5 1.8 19.0 13.5 17
22 25.0 M18x1.0 5.5 2.0 19.0 16.5 22
22 25.0 M18x1.0 5.5 2.0 19.0 16.5 22
22 25.0 M18x1.0 5.5 2.0 20.5 16.5 22
22 25.0 M18x1.0 5.5 2.0 20.5 16.5 22
E maxi
S 1
Panel cut-out (page 33)
www.lemo.com
11
®
®
ECG Fixed socket with 2 nuts, key (N) or key (S),
protruding shell, IP50 (back panel mounting)
N
M
S3
Reference
Dimensions (mm)
E maxi
Model
Series
FF
A
B
e
E
M
N
S3
9
ECG
10 10.2 M7x0.5 1.5 2.5 13.9
Panel cut-out (page 33)
Note: this socket can be used without the hexagonal nut. It can be directly fastened
into the device, the notched nut is used as a tightening nut.
ECG Fixed socket with 2 nuts, key (N) or key (S), protruding
shell, print contacts, IP50 (back panel mounting)
3
N
M
S3
Reference
Dimensions (mm)
E maxi
Model
Series
FF
A
B
e
E
M
N
S3
9
ECG
10 10.2 M7x0.5 1.5 2.5 13.9
Panel cut-out (page 33)
Note: this socket can be used without the hexagonal nut. It can be directly fastened
into the device, the notched nut is used as a tightening nut.
EEG Fixed socket, nut fixing, key (N) or keys (P, S and T), IP50
(back panel mounting)
N
S 3 S 1
M
Reference
Dimensions (mm)
Model
Series
A
B
e
E
M
N
P
S1 S2 S3
EEG
EEG
EEG
EEN
EEP
EES
EET
0F
1F
2F
3F
3F
3F
3F
13 12 M10x0.75 6.0 2.5 19.0 8.5 9.0 11 10.5
17 15 M13x0.75 6.2 3.2 19.0 9.4 11.5 14 14.0
20 19 M16x1.00 6.4 4.0 19.0 10.4 14.5 17 16.0
22 22 M18x1.00 6.4 4.0 19.0 10.4 16.5 19 20.0
22 22 M18x1.00 6.4 4.0 19.0 10.4 16.5 19 20.0
22 22 M18x1.00 6.4 4.0 20.5 10.4 16.5 19 20.0
22 22 M18x1.00 6.4 4.0 20.5 10.4 16.5 19 20.0
E maxi
S 2
P
Panel cut-out (page 33)
EFG Fixed socket, nut fixing, key (N) or keys (P, S and T),
(back panel mounting)
N
S 1
M
Reference
Dimensions (mm)
Model
Series
1F
A
B
e
E
M
N
P
S1 S2
EFG
17 17 M13x0.75 6.2 3.2 19.0 9.4 11.5 14
E maxi
S 2
Panel cut-out (page 33)
P
12
www.lemo.com
®
®
EHG Fixed socket, nut fixing, key (N) or keys (P, S, T, W and X),
(back panel mounting)
Reference
Dimensions (mm)
Model
Series
A
B
e
E
M
N
P
S1 S2
EHG
EHG
EHG
EHG
EHN
EHP
EHS
EHT
EHW
EHX
EHW
EHX
EHG
FF
0F
1F
2F
3F
3F
3F
3F
4F
4F
LF
LF
5F
10 11 M7x0.50 3.0 2.5 15.0 12.0 6.4
8
13 14 M10x0.75 3.0 2.5 19.0 14.5 9.0 11
17 17 M13x0.75 3.0 3.2 19.0 14.5 11.5 14
20 20 M16x1.00 3.0 4.0 19.0 14.5 14.5 17
22 23 M18x1.00 3.0 4.0 19.0 14.5 16.5 19
22 23 M18x1.00 3.0 4.0 19.0 14.5 16.5 19
22 23 M18x1.00 3.0 4.0 20.5 16.0 16.5 19
22 23 M18x1.00 3.0 4.0 20.5 16.0 16.5 19
29 29 M24x1.00 3.0 5.0 19.0 14.5 22.0 25
29 29 M24x1.00 3.0 5.0 21.0 16.5 22.0 25
32 32 M27x1.00 6.4 5.0 24.3 20.0 25.0 28
32 32 M27x1.00 6.4 5.0 24.3 20.0 25.0 28
38 38 M33x1.00 6.4 5.0 28.4 24.0 31.0 34
N
P
S 2
M
E maxi
S 1
Panel cut-out (page 33)
EDG Fixed socket with flange, key (N) or keys (P and S),
2 holes fixing, protruding shell
Reference
Dimensions (mm)
N
D
Model
Series
1F
A
B
C
d
D
H
M
2
N
P
EDG
25.4 5.9 11.5 3.5 14 19.3
19 16.5
Panel cut-out (page 33)
M
ø d
P
PHG Free socket, key (N) or keys (P, S, T, W and X)
Reference
Dimensions (mm)
Model
Series
A
B
L
X
PHG
PHG
PHG
PHG
PHN
PHP
PHS
PHT
PHW
PHX
PHW
PHX
PHG
FF
0F
1F
2F
3F
3F
3F
3F
4F
4F
LF
LF
5F
8.5 6.3 20.7 5.7
12.0 9.0 26.7 8.0
14.0 10.7 26.7 8.0
17.0 14.0 26.7 8.0
19.0 16.0 26.7 8.0
19.0 16.0 26.7 8.0
19.0 16.0 28.2 8.0
19.0 16.0 28.2 8.0
26.0 21.2 26.7 8.0
26.0 21.2 28.7 8.0
29.0 24.2 32.2 8.0
29.0 24.2 32.2 8.0
35.0 30.2 37.2 8.0
L
X
www.lemo.com
13
®
®
PE● Fixed socket, nut fixing, key (N)
or keys (P, S, T, W and X), (back panel mounting)
Dimensions (mm)
Reference
A
B
C
e
E
L
M
S1 S2
X
Model
Series
PE●
PE●
PE●
PE●
PEN
PEP
PES
PET
PEW
PEX
PEW
PEX
PE●
FF 1) 10 6.3 11 M7x0.50 6.0 20.7 2.5 6.4
–
5.7
0F
1F
2F
3F
3F
3F
3F
4F
4F
LF
LF
5F
13 9.0 13 M10x0.75 6.0 26.7 2.5 9.0 11 8.0
17 10.7 17 M13x0.75 6.2 26.7 3.2 11.5 14 8.0
20 14.0 20 M16x1.00 6.4 26.7 4.0 14.5 17 8.0
22 16.0 22 M18x1.00 6.4 26.7 4.0 16.5 19 8.0
22 16.0 22 M18x1.00 6.4 26.7 4.0 16.5 19 8.0
22 16.0 22 M18x1.00 6.4 28.2 4.0 16.5 19 8.0
22 16.0 22 M18x1.00 6.4 28.2 4.0 16.5 19 8.0
29 21.2 29 M24x1.00 6.4 26.7 5.0 22.0 25 8.0
29 21.2 29 M24x1.00 6.4 28.7 5.0 22.0 25 8.0
32 24.2 32 M27x1.00 6.4 32.2 5.0 25.0 28 8.0
32 24.2 32 M27x1.00 6.4 32.2 5.0 25.0 28 8.0
38 30.2 38 M33x1.00 6.4 37.2 5.0 31.0 34 8.0
L
S 1
M
X
E maxi
S 2
Panel cut-out (page 33)
Note: 1) fitted with notched nut GEG.
PB● Fixed socket with flange, key (N)
or keys (P, S, T, W and X), 2 holes fixing
Reference
Dimensions (mm)
Model
Series
A
B
C
d
D
H
L
M
N
X
PB●
PB●
PB●
PBN
PBP
PBS
PBT
PBW
PBX
PB●
0F
1F
2F
3F
3F
3F
3F
4F
4F
5F
27 9.0 11.0 3.2 15 21.4 26.7
27 10.7 13.0 3.2 15 21.4 26.7
31 14.0 16.0 3.2 18 25.9 26.7
38 16.0 17.5 3.2 20 29.0 26.7
38 16.0 17.5 3.2 20 29.0 26.7
38 16.0 17.5 3.2 20 29.0 28.2
38 16.0 17.5 3.2 20 29.0 28.2
41 21.2 23.0 3.2 26 32.0 26.7
41 21.2 23.0 3.2 26 32.0 28.7
44 30.2 32.0 3.2 33 38.2 37.2
2
2
2
2
2
2
2
2
2
2
4
4
4
4
4
4
4
4
4
4
8
8
8
8
8
8
8
8
8
8
D
L
X
Panel cut-out (page 33)
M
N
ø d
14
www.lemo.com
®
®
Watertight PCB models
HEN fixed sockets allow the device on which they are fitted to reach a protection index of IP68 as per IEC 60529 (unma-
ted). These models are identified by a letter «P» at the end of the reference. Epoxy resin is used to seal these models.
They can be mated with all plugs of the same series to achieve an IP67 protection index between the plug and socket.
Technical Characteristics
Mechanical and Climatical
Characteristics 1)
Value
Standard
Series / Shell material
Temperature range
-15° C, +100° C
-50° C, +150° C
All; code I, X or Y
Temperature range
All; code C or variant with silicone gasket final code (S)
Protection index unmated
IP68
5 bars
IEC 60529
IEC 60512-7 test 14d
All
All
Maximum operating pressure 2)
Note: 1) see also page 10. 2) this value corresponds to the maximum allowed pressure difference for the assembled socket.
HE● Fixed socket, nut fixing, key (N) or keys (P, S, T, W and X),
for printed circuit, (back panel mounting)
Reference
Model Series
FF 1) 10 11 M7x0.50 3.0 5.08 18.2 2.5 12.0 6.4 8.2 15.0
Dimensions (mm)
A
B
e
E
H
L
M
P
S1 S2
X
HE●
HE●
HE●
HE●
HEN
HEP
HES
HET
HEW
HEX
HEW
HEX
HE●
0F
1F
2F
13 14 M10x0.75 3.0 5.08 21.5 2.5 14.5 9.0 11.0 17.5
17 17 M13x0.75 3.0 7.62 21.5 3.2 14.5 11.5 14.0 17.5
20 20 M16x1.00 3.0 8.89 21.5 4.0 14.5 14.5 17.0 17.5
L
3F 2) 22 23 M18x1.00 3.0 11.43 21.5 4.0 14.5 16.5 19.0 17.5
3F 2) 22 23 M18x1.00 3.0 11.43 21.5 4.0 14.5 16.5 19.0 17.5
3F 2) 22 23 M18x1.00 3.0 11.43 23.0 4.0 16.0 16.5 19.0 19.0
3F 2) 22 23 M18x1.00 3.0 11.43 23.0 4.0 16.0 16.5 19.0 19.0
X
3
P
S 2
H
M
4F
4F
LF
LF
5F
29 29 M24x1.00 3.0 15.24 21.5 5.0 14.5 22.0 25.0 17.5
29 29 M24x1.00 3.0 15.24 23.5 5.0 16.5 22.0 25.0 19.5
32 32 M27x1.00 6.4 16.51 26.3 5.0 20.0 25.0 28.0 23.5
32 32 M27x1.00 6.4 16.51 26.3 5.0 20.0 25.0 28.0 23.5
38 38 M33x1.00 6.4 20.32 32.2 5.0 24.0 31.0 34.0 27.4
E maxi
S 1
Epoxy resin
Panel cut-out (page 33)
PCB drilling pattern (page 34)
Note: 1) fitted with notched nut GEG.
2) for chrome plated version (material code «C»), A = 24 mm and S2 = 20 mm.
HE● Fixed socket, nut fixing, key (N) or key (P),
with elbow (90°) contacts for printed circuit,
(back panel mounting)
Reference
Dimensions (mm)
N
Model
Series
A
B
e
E
H
M
N
P
S1 S2
P
M
HE●
HE●
HE●
0F
1F
2F
13 14 M10x0.75 3.0 20 2.5 18.5 14.5 9.0 11
17 17 M13x0.75 3.0 20 3.2 18.5 14.5 11.5 14
20 20 M16x1.00 3.0 20 4.0 18.5 14.5 14.5 17
S 2
Panel cut-out (page 33)
PCB drilling pattern (page 35)
S 1
E maxi
2
www.lemo.com
15
®
®
Models for Fibre Optic
The 2F series has also been designed to allow fibre optic transmissions. This compact connector uses our F7 fibre optic
contact but requires a specific plug with extended shell (T-adapter). The main features are:
– Multi fibre option with 2 optical contacts
– Mixed option with 2 FO + 2 LV contacts
– Optical contact with ceramic ferrules diametre 1.25 mm
Technical Characteristics of optical contacts
Mechanical and Climatical
Optical
Characteristic
Value
> 1000 cycles
Standard
Characteristic
Value
Standard
Method
Mating durability
IEC 61300-02-02
Average insertion loss
fibre 9/125 µm
0.18 dB IEC 61300-03-34 Method 2
Damp heat steady state up to 93 % RH at 40°C IEC 61300-02-19
High temperature
Low temperature
Cable retention
+85°C
IEC 61300-02-18
IEC 61300-02-17
IEC 61300-02-04
–
Average insertion loss
fibre 50/125 µm
0.25 dB IEC 61300-03-34 Method 2
Coupler
-40°C
100 N
Return loss fibre 9/125 µm
(UPC)
IEC 61300-03-06
≥45 dB
Method
Vibration (3 axes)
100 to 2000 Hz, 2 hrs
Change of temperature -40 to +75°C
IEC 61300-02-22
Coupler
Method
Return loss fibre 9/125 µm
(Hand polish)
IEC 61300-03-06
>25 dB
Temperature/humidity
-10 to +65°C at 93 % RH IEC 61300-02-21
FGG Straight plug, key (N) or keys (P and S)
~L
Reference
Dimensions (mm)
S1 S2
17.0 14.0 89.5 79.5 15.0 14.0
~M
Model
Series
2F
A
B
L
M
FGG
S 2
S 1
EHG Fixed socket, nut fixing, key (N)
or keys (P and S), (back panel mounting)
L
P
S 2
M
Reference
Dimensions (mm)
Model
Series
2F
A
B
e
E
3
L
M
4
P
S1 S2
EHG
20 20 M16x1
21.8
14.5 14.5 17
Panel cut-out (page 33)
E maxi
S 1
Note: Other models of socket can be made available.
Connectors for fibre-optic are delivered without the fibre optic contacts, they must be ordered separately (see page 25).
ForT-type cable adapter see page 20.
16
www.lemo.com
®
®
Alignment Key
Alignment Key and Polarized Keying System
F series connector model part numbers are composed of three letters. The LAST LETTER indicates the keys correspon-
ding to a particular contact type. For example, straight plugs with N, P or W keys, are fitted with male contacts; whereas
with S, T or X keys, plugs are fitted with female contacts. Sockets with N, P or W keys, are fitted with female contacts; whe-
reas with S, T or X keys, sockets are fitted with male contacts.
Front view of a socket
Contact type
Electrical or Optical
Series FF
Series 0F to 2F
Angles
Series 3F
Nb
of keys
Colour
code
Note
Plug
Socket
β
γ
β
γ
β
γ
●
●
●
●
●●N
●●P
●●S
●●T
165°
–
30°
–
165°
150°
155°
160°
30°
60°
50°
40°
150°
145°
140°
135°
60°
70°
80°
90°
blue
yellow
red
male
male
female
female
male
3
155°
–
50°
–
female
female
γ
green
male
Front view of a socket
Series 4F-LF-5F
Angles
Contact type
Nb
of keys
Colour
code
Note
Plug
Socket
α
β
γ
δ
●
●
●●W
●● X
95°
100°
115°
125°
35°
40°
25°
20°
blue
red
male
female
male
5
female
● First choice alternative ● Special order alternative
www.lemo.com
17
®
®
Insert configuration
Multipole
1
2
4
3
4
3
1
2
Contact
type
Male crimp contacts
Female crimp contacts
●
●
●
●
●
●
●
●
●
●
●
●
303
304
302
303
304
305
3
4
2
3
4
5
0.5
0.5
0.9
0.9
0.7
0.7
–
–
28-30-32 1.35 1.10
28-30-32 1.05 1.05
3.0
2.0
FF
0F
●
●
●
●
20-22-24 1.45 1.20 10.0
20-22-24 1.70 1.60
22-24-26 1.35 1.10
22-24-26 1.25 1.20
8.0
7.0
6.5
●
●
●
●
●
●
●
●
●
●
●
●
303
305
307
308
3
5
7
8
1.3
0.9
0.7
0.7
18-20 1.60 1.85 12.0
1F
2F
20-22-24 1.30 1.55
22-24-26 1.45 1.45
22-24-26 1.30 1.30
9.0
7.0
5.0
3)
4)
●
●
●
●
●
304
308
310
312
319
4
1.3
0.9
0.9
0.7
0.7
–
–
18-20 2.70 1.85 15.0
20-22-24 1.95 1.95 10.0
2
3
1
4
1
4
2
3
●
●
●
●
●
●
●
●
8
10
12
19
20-22-24 1.80 2.10
22-24-26 1.65 2.00
22-24-26 1.55 1.65
8.0
7.0
5.0
●
●
●
●
3F
4F
322
330
22
30
0.7
0.7
–
–
22-24-26 1.70 1.45
22-24-26 1.35 1.20
5.5
3.5
●
●
340
40
0.7
–
22-24-26 1.35 1.30
2.0
Note: Other types available on request, based on existing contact configurations of the B series.
1) see calculation method, caution and suggested standard on pages 39 and 40.
2) the mentioned AWG range apply to the standard crimp contact of fig.1. Contacts with reduced crimp barrel are available for smaller conductor.
See page 20 for explanation and availability.
3) view for EHS socket.
4) view for FGS plug.
18
www.lemo.com
®
®
Multipole
1
2
4
3
4
3
1
2
Contact
type
Male crimp contacts
Female crimp contacts
LF
5F
●
●
368
68
0.7
–
22-24-26 1.5
1.5
2.5
●
●
●
●
●
●
●
●
350
355
364
366
50
55
64
66
0.9
0.9
0.9
0.9
–
–
–
–
20-22-24 1.20 1.45
20-22-24 2.00 2.10
20-22-24 1.35 1.85
20-22-24 1.30 1.80
6.0
5.0
3.0
3.0
Note: Other types available on request, based on existing contact configurations of the B series.
1) see calculation method, caution and suggested standard on pages 39 and 40.
2) the mentioned AWG range apply to the standard crimp contact of fig.1. Contacts with reduced crimp barrel are available for smaller conductor.
See page 20 for explanation and availability.
Multi fibre and Mixed fibre optic + LV
Low Voltage contact
Contact
type
Crimp
contact
Male crimp contacts
Female crimp contacts
03A
93B
2
2
–
4
–
–
–
–
–
2F
1
2
4
3
4
3
1
2
0.7
●
0.85
1.25
6.0
Note: Other types available on request, based on existing contact configurations of the B series.
1) see calculation method, caution and suggested standard on pages 39 and 40.
2) the mentioned AWG range apply to the standard crimp contact of fig.1. Contacts with reduced crimp barrel are available for smaller conductor.
See page 20 for explanation and availability.
www.lemo.com
19
®
®
Housings
Availability
Outer shell
Latch sleeve
Material
Gaskets
Ref.
for plug
for sockets
Surface
Surface
Material
treatment
treatment
FF 0F 1F 2F 3F 4F LF 5F FF 0F 1F 2F 3F 4F LF 5F
I
–
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
–
●
●
–
●
●
–
●
●
–
●
●
–
●
●
–
●
●
–
●
●
–
●
●
–
●
●
–
●
●
–
Aluminium alloy
Aluminium alloy
Aluminium alloy
Brass
NiCorAl Special bronze/brass NiCorAl
FPM/FKM
FPM/FKM
FPM/FKM
X
Y
C
–
Nickel1) Special bronze/brass
Nickel1)
Beryllium copper
Chrome Special bronze/brass
Nickel
Nickel
●
–
–
–
–
●
●
●
●
–
–
–
Nickel Silicone MQ/MVQ
Note: 1) anthracite colour. See page 10 for detail on Material and Treatments.
● First choice alternativeꢀ ꢀ ● Special order alternative
Contacts
Crimp contacts for plugs, free or fixed sockets
Ref.
Contact type
Ref.
Contact type
There are 2 forms of crimp barrels:
C
B
G
D
Z
Male crimp (fig. 1)
Male crimp (fig. 2)
Male crimp (fig. 2)
Male straight print
No contact (for multi FO)
M
P
U
N
V
Female crimp (fig. 1)
Female crimp (fig. 2)
Female crimp (fig. 2)
Female straight print
Male or female elbow print
– per fig. 1, the standard design
– per fig. 2, with reduced crimp barrel for small conductors.
Fig. 1
ø A
ø C
ø C
Dimension of crimp barrels
ø A
Contact
Ref. contact type
Conductor
AWG
Section (mm2)
ø A ø C Form
Male
Female
(mm) (mm) per fig.
min. max. min. max.
Fig. 2
ø A
ø A
ø C
ø C
281) 0.035 0.09
22 0.140 0.34
28 0.035 0.09
20 0.250 0.50
22 0.140 0.34
28 0.035 0.09
18 0.500 1.00
C
C
B
C
B
G
C
M
M
P
0.5 0.42
1
1
2
1
2
2
1
32
26
32
24
26
32
20
0.80
0.7
0.45
M
P
1.10
0.9 0.80
0.45
U
M
1.3 1.40
Note: 1) for a given AWG, the diameter of some stranded conductor designs is larger than the solder cup diameter. Make sure that the maximum conduc-
tor diameter is smaller than ø C.
Cable Fixing
T type cable adapter
Cable ø
Adapter
ø A
Adapter with gasket
part number
Bend relief to be used 1)
Reference
max.
min.
T46Z
T56Z
T66Z
4.6
5.6
6.6
4.5
5.5
6.5
3.6
4.6
5.6
FGG.2F.846.TNV
FGG.2F.856.TNV
FGG.2F.866.TNV
GMA.2B.040.D●
GMA.2B.050.D●
GMA.2B.060.D●
2F
Note: 1) to order separately.
20
www.lemo.com
®
®
Variant
Some options are available, they are identify with specific letters in the variant position.
– F apply to plug with a reduced unlatching force, such option allows disconnection if the cable is pulled accidentally.
– Connectors with code material I, X or Y are delivered with FPM/FKM gasket as a standard.
As an option they can be delivered with Silicone gasket. Add the «S» in the variant position.
– P indicated that the watertight models HE● are potted with epoxy resin.
Reference
Model
Reduced
Silicone
gasket
Potted and
Potted
unlatching force
silicone gasket
FG●
E●●
HE●
F
–
–
S
S
–
–
–
P
–
–
PS
www.lemo.com
21
®
®
LEMO F1 ECU systems connectors
LEMO F Series connectors feature on the new ECU being LEMO connectors can also be idealy used for HIL setups
provided by Microsoft® and McLaren Electronic Systems® (hardware in the loop), for vehicle electronic development,
for the FIA Formula One World Championship in 2008, crash test setups, for ECU calibration and test, and also in
2009 and 2010.
battery status diagnosis.
The applications include the hub interface unit, lap trigger LEMO connectors have full EMC screening and offer
receiver, powerbox and display connections. To assist secure push-pull connections for Flexray, CAN bus or USB
users, information on corresponding LEMO connectors that protocol, PWM (pulse width modulation), digital I/O and
are required to connect to the system are described here power supply.
below giving full part numbers and application.
F1 ECU SYSTEM
Based on diagram courtesy of McLaren Electronic Systems Ltd
HIU-3
HIU-3
Hub Interface Unit
Hub Interface Unit
LRX-310B
Lap Trigger Receiver
LEMO Connector
HES.1F.308.XLDP
HIU-3
IN 4 POS.
LEMO Connector
EHS.0F.303.XLCY
LEMO Connector
LEMO Connector
HES.1F.308.XLDP
HEN.FF.304.SLNP (2 off)
HEN.FF.304.SLNPY (2 off)
PCU-6C
Dashboard Display
LIU-4
LVDT Interface Unit
SIU-300
Switch Interface Unit
LEMO Connector
HEP.2F.310.XLNP
PB2006 Powerbox
TAG-31B
Main Control Unit
Ignition
LEMO Connector
EHS.2F.304.XLY
Battery
Injection
LEMO Connector
HEN.2F.319.XLNP
Alternator
HIU-3
HIU-3
Hub Interface Unit
Hub Interface Unit
HIU (1, 2, 3 & 4) Hub Interface Unit
PB2006 Powerbox
Unit connectors
Interface connectors
FGS.1F.308.YLM
Spare contacts
Unit connectors
EHS.2F.304.XLY
Interface connectors
FGS.2F.304.YLY
Spare contacts
HES.1F.308.XLDP
HEN.FF.304.SLNP 1) FGN.FF.304.YLC
HEN.FF.304.SLNPY 1) FGN.FF.304.YLC
EGG.0B.655.ZZM
FGG.00.554.ZZC
FGG.00.554.ZZC
FGN.1F.565.ZZC 1)
EGN.1F.665.ZZM 2)
FGG.0B.560.ZZC
FGG.0B.555.ZZC
HEP.2F.310.XLNP
HEN.2F.319.XLNP
FGP.2F.310.YLC
FGN.2F.319.YLC
Notes: 1) outershell in stainless steel (AISI 303, 304).
Notes: 1) male contact. 2) female contact.
LRX 310B Lap Trigger Receiver
PCU-6C Dashboard display
Unit connector
Interface connector
FGS.0F.303.YLM
Spare contact
Unit connector
Interface connector
FGS.1F.308.YLM
Spare contact
EHS.0F.303.XLCY
EGG.0B.660.ZZM
HES.1F.308.XLDP
EGG.0B.655.ZZM
22
www.lemo.com
®
®
Spare parts
FGG-EGG Crimp contacts
Contact (mm)
Contact part number
female for socket male for socket
Fig. 1
ø A
ø C
male for plug
female for plug
0.5
0.42 FGG.00.554.ZZC EGG.00.654.ZZM FGG.00.554.ZZC EGG.00.654.ZZM
FF
0F
1F
0.9
0.7
1.10 FGG.0B.560.ZZC EGG.0B.660.ZZM FGG.0B.560.ZZC EGG.0B.660.ZZM
0.80 FGG.0B.555.ZZC EGG.0B.655.ZZM FGG.0B.555.ZZC EGG.0B.655.ZZM
1.3
0.9
0.7
1.40 FGN.1F.565.ZZC EGN.1F.665.ZZM FGN.1F.565.ZZC EGN.1F.665.ZZM
1.10 FGG.0B.560.ZZC EGG.0B.660.ZZM FGG.0B.560.ZZC EGG.0B.660.ZZM
0.80 FGG.0B.555.ZZC EGG.0B.655.ZZM FGG.0B.555.ZZC EGG.0B.655.ZZM
ø A
ø A
ø C
ø C
1.3
0.9
0.7
1.40 FGN.1F.565.ZZC EGN.1F.665.ZZM FGN.1F.565.ZZC EGN.1F.665.ZZM
1.10 FGG.0B.560.ZZC EGG.0B.660.ZZM FGG.0B.560.ZZC EGG.0B.660.ZZM
0.80 FGG.0B.555.ZZC EGG.0B.655.ZZM FGG.0B.555.ZZC EGG.0B.655.ZZM
2F
0.7
0.7
0.7
0.9
0.80 FGG.0B.555.ZZC EGG.0B.655.ZZM FGG.0B.555.ZZC EGN.3F.655.ZZM
0.80 FGG.2B.555.ZZC EGG.0B.655.ZZM FGG.0B.555.ZZC EGG.2B.655.ZZM
0.80 FGG.3B.555.ZZC EGG.2B.655.ZZM FGG.0B.555.ZZC EGG.3B.655.ZZM
1.10 FGG.3B.560.ZZC EGG.3B.660.ZZM FGG.3B.560.ZZC EGG.3B.660.ZZM
3F
4F
LF
5F
Contact (mm)
Contact part number
female for socket male for socket
Fig. 2
ø A
ø C
male for plug
female for plug
0.80 FGG.0B.561.ZZC EGG.0B.661.ZZM FGG.0B.561.ZZC EGG.0B.661.ZZM
0.45 FGG.0B.562.ZZC EGG.0B.662.ZZM FGG.0B.562.ZZC EGG.0B.662.ZZM
0.45 FGG.0B.556.ZZC EGG.0B.656.ZZM FGG.0B.556.ZZC EGG.0B.656.ZZM
0.9
0.7
0F
1F
2F
0.80 FGG.0B.561.ZZC EGG.0B.661.ZZM FGG.0B.561.ZZC EGG.0B.661.ZZM
0.45 FGG.0B.562.ZZC EGG.0B.662.ZZM FGG.0B.562.ZZC EGG.0B.662.ZZM
0.45 FGG.0B.556.ZZC EGG.0B.656.ZZM FGG.0B.556.ZZC EGG.0B.656.ZZM
0.9
0.7
ø A
ø A
ø C
ø C
0.80
0.45
0.45
FGG.0B.561.ZZC EGG.0B.661.ZZM FGG.0B.561.ZZC EGG.0B.661.ZZM
FGG.0B.562.ZZC EGG.0B.662.ZZM FGG.0B.562.ZZC EGG.0B.662.ZZM
FGG.0B.556.ZZC EGG.0B.656.ZZM FGG.0B.556.ZZC EGG.0B.656.ZZM
0.9
0.7
0.7
0.7
0.7
0.9
0.45 FGG.0B.556.ZZC EGG.0B.656.ZZM FGG.0B.556.ZZC EGN.3F.656.ZZM
0.45 FGG.2B.556.ZZC EGG.0B.656.ZZM FGG.0B.556.ZZC EGG.2B.656.ZZM
0.45 FGG.3B.556.ZZC EGG.2B.656.ZZM FGG.0B.556.ZZC EGG.3B.656.ZZM
0.80 FGG.3B.561.ZZC EGG.3B.661.ZZM FGG.3B.561.ZZC EGG.3B.661.ZZM
3F
4F
LF
5F
24
www.lemo.com
®
®
FFS.F7 Male F7 Fibre Optic Contact
Ferrule hole
ø (µm)
Fibre ø
core/cladding (µm)
Note
Part number
~ L
FFS.F7.125.LCE23
FFS.F7.126.LCE23
FFS.F7.128.LCE23
125
126
128
l
l
9/125
50/125
62.5/125
PSS.F7 Female F7 Fibre Optic Contact
Ferrule hole
ø (µm)
Fibre ø
core/cladding (µm)
Note
Part number
PSS.F7.125.LCE23
PSS.F7.126.LCE23
PSS.F7.128.LCE23
125
126
128
l
l
~L
8.2
9/125
50/125
62.5/125
Note: alignment device part number: PSS.F7.290.NZZ
GBA Locking washers
Dimensions (mm)
ø A
ø C
For
models
Series
Part number
A
C
L
L
GBA.00.250.FN
GBA.0S.250.FN
GBA.1S.250.FN
GBA.2S.250.FN
GBA.3S.250.FN
FF
0F
1F
2F
3F
9.5
12.5
7.1 1.0 ECl
9.1 1.0 EGl
16.0 12.1 1.0 EGl
19.5 15.1 1.2 EGl
25.0 18.1 1.4 EGl, PEl, EEl, EHl
Note: to order this accessory separately, use the above part numbers.
l Material: Nickel-plated bronze (3 µm)
GEA Hexagonal nuts
Dimensions (mm)
For
models
Series
FF
Part number
A
A
9
B
e
L
L
e
GEA.00.240.LN
GEA.0S.240.LN
GEA.1S.240.LN
GEA.2S.240.LN
GEA.3S.240.LN
10.2 M7x0.50 2.0 ECl
0F 11 12.4 M9x0.60 2.0 EGl
1F 14 15.8 M12x1.00 2.5 EGl
2F 17 19.2 M15x1.00 2.7 EGl
3F 22 25.0 M18x1.00 3.0 EGl
Note: to order this part separately use the above part numbers.
Also available in aluminium alloy (GEA.ll.240.RT).
l Material: Nickel-plated brass (3 µm)
GEG Notched nut
ø A
e
L
Dimensions (mm)
For
models
Series
Part number
A
B
e
L
GEG.00.240.RN
FF 8.7 10 M7x0.50 2.5 HEl, ECl, PEl
l Material: Nickel-anthracite aluminium alloy
www.lemo.com
25
®
®
GEC Conical nut
Dimensions (mm)
For
Series
Part number
models
A
8
B
e
L
GEC.FF.240.Rl
GEC.0F.240.Rl
GEC.1F.240.Rl
GEC.2F.240.Rl
GEC.3F.240.Rl
GEC.4F.240.Rl
GEC.LF.240.Rl
GEC.5F.240.Rl
PEl, EHl, HEl
10 M7x0.50 2.5
FF
PEl, EEl, EHl, HEl
PEl, EEl, EHl, HEl
PEl, EEl, EHl, HEl
PEl, EEl, EHl, HEl
PEl, EHl, HEl
0F 11 13 M10x0.75 2.5
1F 14 17 M13x0.75 3.2
2F 17 20 M16x1.00 4.0
3F 19 22 M18x1.00 4.0
4F 25 29 M24x1.00 5.0
LF 28 32 M27x1.00 5.0
5F 34 38 M33x1.00 5.0
A
e
L
PEl, EHl, HEl
PEl, EHl, HEl
Ref.
Colour
Keying
Ref.
Colour
Keying
blue
yellow
N or W
P
red
green
S or X
T
A
J
R
V
Note: the last position “l” of the part number indicates the colour. To obtain
the required colour, refer to the above table and change the position “l”
of the part number to the corresponding letter.
l Material: Anodized aluminium alloy
26
www.lemo.com
®
®
Accessories
BFl Plug caps, with keys (N or P)
L
Dimensions (mm)
N1)
Series
Part number
A
B
L
BFl.1F.100 PCSG
BFl.2F.100.PCSG
1F
2F
12.0 13.3 12.6 62
15.0 16.4 12.8 75
l Body material: PA6.6 grey
l Cord material: Polyamide 6
N
l Maximum operating temperature: 100°C
l Protection index: IP51 according to IEC 60529
Note: 1) the tolerance on this dimension is ± 5 mm.
BRA Blanking caps for fixed sockets
L
M
Dimensions (mm)
Series
Part number
A
B
L
M
N
BRA.1F.200.PZSG
BRA.2F.200.PZSG
1F 14.0 13.7 12.1 5.3 65.5
2F 18.0 16.5 12.0 5.6 65.5
l Body material: PA6.6 grey
l Band: PET
l Maximum operating temperature: 100°C
l Protection index: IP51 according to IEC 60529
BRF Blanking caps, with latching for free sockets
Dimensions (mm)
L
Series
Part number
A
L
M
N1)
M
BRF.FF.200.YAV
BRF.0F.200.XAV
BRF.1F.200.XAV
BRF.2F.200.XAV
BRF.3F.200.XAV
BRF.4F.200.XAV
BRF.LF.200.XAV
FF
0F
1F
2F
3F
4F
LF
8.5 20.0 12.0 60
12.0 25.5 15.6 85
14.0 25.8 15.7 85
17.0 25.8 15.6 85
19.0 27.8 17.6 120
26.0 30.3 20.1 120
29.0 34.7 20.1 120
sliding loop
Note: 1) the tolerance on this dimension is ± 5 mm.
This cap is suitable for use with any alignment key configuration.
l Lanyard material: Stainless steel
l Crimp ferrule material: Nickel-plated brass + polyolefin
l Maximum operating temperature: 135°C
lꢀ Watertightness: IP67 according to IEC 60529
BRE Blanking caps, with latching for fixed sockets
Dimensions (mm)
L
Series
Part number
A
L
M
N1)
M
BRE.FF.200.YAV
BRE.0F.200.XAV
BRE.1F.200.XAV
BRE.2F.200.XAV
BRE.3F.200.XAV
BRE.4F.200.XAV
BRE.LF.200.XAV
FF
0F
1F
2F
3F
4F
LF
8.5 20.0 12.0 60
12.0 25.5 15.6 85
14.0 25.8 15.7 85
17.0 25.8 15.6 85
19.0 27.8 17.6 120
26.0 30.3 20.1 120
29.0 34.7 20.1 120
Note: 1) the tolerance on this dimension is ± 5 mm.
This cap is suitable for use with any alignment key configuration. The
BRE.0F cap has no keying and can be therefore used with any socket.
l Lanyard material: Stainless steel
l Crimp ferrule material: Nickel-plated brass + polyolefin
l Maximum operating temperature: 135°C
lꢀ Watertightness: IP67 according to IEC 60529
28
www.lemo.com
®
®
BFG Plug caps
Dimensions (mm)
L
Series
Part number
A
B
4
6
6
6
8
8
8
L
N1)
60
85
85
85
B
BFG.FF.100.XAZ
BFG.0F.100.XAZ
BFG.1F.100.XAZ
BFG.2F.100.XAZ
BFG.3F.100.XAZ
BFG.4F.100.XAZ
BFG.LF.100.XAZ
FF
0F
1F
2F
3F
4F
LF
8.5
14
18
18
18
20 120
20 120
24 120
12.0
14.0
17.0
19.0
26.0
30.0
sliding loop
Note: 1) the tolerance on this dimension is ± 5 mm.
This cap is suitable for use with any alignment key configuration.
l Lanyard material: Stainless steel
l Crimp ferrule material: Nickel-plated brass + polyolefin
l Maximum operating temperature: 135°C
lꢀ Watertightness: IP67 according to IEC 60529
Heatshrink boot
Straight boot
Elbow boot
cable
Part number
ø
Supplier
LEMO
Series
BEFORE HEATING
BEFORE HEATING
min.
(mm)
Straight
Elbow 90°
FF
GMA.10.290.DN GHA.10.210.DN 2) 2.2
202 A 111-25/86 222 A 111-25/86 1) 3.8
0F-1F-2F-3F
202 A 111-25
222 A 111-25
2) 3.8
202 A 121-25/86 222 A 121-25/86 1) 5.3
Raychem®
1F-2F-3F-4F
202 A 121-25
222 A 121-25
2) 5.3
4F-LF-5F 202 A 142-25/86 222 A 142-25/86 1) 7.4
AFTER HEATING
AFTER HEATING
4F-5F
0F-1F-2F-3F
1F-2F-3F-4F
4F-5F
202 A 142-25
104-1-G
105-1-G
222 A 142-25
1108-1-G
1106-1-G
2) 7.4
2) 3.8
2) 5.6
2) 7.1
Hellermann®
101-1-G
1104-2-G
1) modified elastomer resistant to fluids with hot melt sealant.
Note:
2) elastomer resistant to fluids. We recommend a thermosetting sealant
with this type of boot.
GRA Insulating washers
Dimensions (mm)
Series
Part number
A
B
E
4
4
4
4
4
4
L
M
T
GRA.0F.269.Gl
GRA.1F.269.Gl
GRA.2F.269.Gl
GRA.3F.269.Gl
GRA.4F.269.Gl
GRA.5F.269.Gl
0F
1F
2F
3F
4F
5F
15 12.0
19 15.0
22 18.5
24 20.5
31 27.5
40 36.5
1.8 1.0 11
2.0 1.1 14
2.2 1.2 17
2.2 1.2 19
2.2 1.2 25
2.2 1.2 34
For EGl sockets with a particular thread dimension, use B series insula-
ting washers (see below).
Dimensions (mm)
Series
Part number
A
B
E
L
M
T
GRA.0S.269.Gl
GRA.1S.269.Gl
GRA.2S.269.Gl
GRA.3S.269.Gl
0F 12.0 10.8 6.0 1.8 1.0 9.9
1F 16.0 13.8 6.5 1.8 1.0 12.2
2F 21.1 17.9 7.3 2.3 1.3 16.2
3F 25.0 21.8 10.3 2.2 1.2 20.2
L
ø A
T
M
Note: the last position “l” of the part number indicates the colour. To
obtain the required colour, refer to the above table and change position
“l” of the part number to the corresponding letter.
Ref.
Colour
Keying
Ref.
Colour
Keying
E maxi
blue
yellow
N or W
P
red
green
S or X
T
A
J
R
V
l Material: Polyamide
www.lemo.com
29
®
®
Tooling
DCG Spanners for hexagonal nuts
N
Dimensions (mm)
Part number
of the nut
Part number
B
L
N
DCG.91.149.0TN
DCG.91.161.1TN
DCG.91.201.4TN
DCG.91.231.7TN
DCG.91.282.2TN
14
16
20
23
28
40
45
52
62
76
50 GEA.00.240.LN
52 GEA.0S.240.LN
65 GEA.1S.240.LN
68 GEA.2S.240.LN
73 GEA.3S.240.LN
ø B
● Material: blackened steel
DCH Spanners for notched nut
ø A
ø B
Dimensions (mm)
Part number
Part number
of the nut
A
B
L
N
DCH.91.101.PA
10.1 12.8 124 48.3 GEG.00.240.RN
● Material: Blue polyurethane
N
DTA Taps
Part number
Series
Thread
00
0S-0B
M7 x 0.5
M9 x 0.6
DTA.99.700.5Z
DTA.99.900.6Z
DPC Manual crimping tool
Part number
DPC.91.701.V
According to specification MIL-C-22520/7-01.
For LEMO contacts ø 0.5-0.7-0.9-1.3 mm
Pneumatic crimping tools
Supplier
LEMO
Part number
DPC.91.701.C
85230
BALMAR
BUCHANAN
621101
According to specification MIL-C-22520/7-01.
For LEMO contacts ø 0.5-0.7-0.9-1.3 mm
30
www.lemo.com
®
®
DCE Positioners for crimp contacts
ø 0.5-0.7-0.9 and 1.3 mm
DCF Extractor for crimp contact
ø 0.5-0.7-0.9 and 1.3 mm
male
female
These positioners are suitable for use with both manual and pneumatic crim-
ping tools according to the MIL-C-22520/7-01 standard.
Connector + Contact
Positioners part number
Extractors
part number
For male
contacts
into plug
For female
For male
contacts
into socket
For female
contacts
into plug
Conductor
AWG
Type
contacts
into socket
303
0.5 0.42 1 28-30-32 DCE.91.050.0VC DCE.91.050.0VM DCE.91.050.0VC DCE.91.050.0VM DCF.91.050.2LT
FF
0F
304
0.9 1.10 1 20-22-24
DCE.91.090.BVC DCE.91.090.BVM DCE.91.090.BVC DCE.91.090.BVM DCF.93.090.4LT
0.9 0.80 2 22-24-26
302
303
0.9 0.45 2 28-30-32 DCE.91.090.AVC DCE.91.090.AVM DCE.91.090.AVC DCE.91.090.AVM DCF.93.090.4LT
0.7 0.80 1 22-24-26
304
305
DCE.91.070.BVC DCE.91.070.BVM DCE.91.070.BVC DCE.91.070.BVM DCF.93.070.4LT
0.7 0.45 2 28-30-32
303
1.3 1.40 1
18-20
DCE.91.131.FVC DCE.91.131.FVM DCE.91.131.FVC DCE.91.131.FVM DCF.93.131.4LT
1F
2F
0.9 1.10 1 20-22-24
0.9 0.80 2 22-24-26
DCE.91.090.BVC DCE.91.090.BVM DCE.91.090.BVC DCE.91.090.BVM DCF.93.090.4LT
305
0.9 0.45 2 28-30-32 DCE.91.090.AVC DCE.91.090.AVM DCE.91.090.AVC DCE.91.090.AVM DCF.93.090.4LT
0.7 0.80 1 22-24-26
307/308
304
DCE.91.070.BVC DCE.91.070.BVM DCE.91.070.BVC DCE.91.070.BVM DCF.93.070.4LT
0.7 0.45 2 28-30-32
1.3 1.40 1
18-20
DCE.91.131.FVC DCE.91.131.FVM DCE.91.131.FVC DCE.91.131.FVM DCF.93.131.4LT
0.9 1.10 1 20-22-24
0.9 0.80 2 22-24-26
DCE.91.090.BVC DCE.91.090.BVM DCE.91.090.BVC DCE.91.090.BVM DCF.93.090.4LT
308
310
0.9 0.45 2 28-30-32 DCE.91.090.AVC DCE.91.090.AVM DCE.91.090.AVC DCE.91.090.AVM DCF.93.090.4LT
0.7 0.80 1 22-24-26
312
319
DCE.91.070.BVC DCE.91.070.BVM DCE.91.070.BVC DCE.91.070.BVM DCF.93.070.4LT
0.7 0.45 2 28-30-32
0.7 0.80 1 22-24-26
322
330
DCE.91.070.BVC DCE.91.070.BVM DCE.91.070.BVC DCE.91.071.FVM DCF.93.070.4LT
0.7 0.45 2 28-30-32
3F
4F
LF
5F
0.7 0.80 1 22-24-26
340
368
DCE.91.072.BVC DCE.91.070.BVM DCE.91.070.BVC DCE.91.072.BVM DCF.93.070.4LT
0.7 0.45 2 28-30-32
0.7 0.80 1 22-24-26
DCE.91.073.BVC DCE.91.072.BVM DCE.91.070.BVC DCE.91.073.BVM DCF.93.070.4LT
0.7 0.45 2 28-30-32
350/354
355/364
366
0.9 1.10 1 20-22-24
DCE.91.093.BVC DCE.91.093.BVM DCE.91.093.BVC DCE.91.093.BVM DCF.91.093.5LT
0.9 0.80 2 22-24-26
Note: see table on page 20 for connector selection and the table on page 24 for contact selection.
A wide variation of strand number and diameter combinations are quoted as being AWG, some of which do not have a large enough cross section to gua-
rantee a crimp as per either MIL-C-22520/1-01 or /7-01. Our technical department is at your disposal to study and propose a solution to all your applications.
ø A
ø A
ø C
ø C
Fig. 1
ø A
ø A
Fig. 2
ø C
ø C
www.lemo.com
31
®
®
Banding tool
Part number
®
®
®
GLEN-AIR
TIE-DEX
AXON
Banding tool
Tie wrap
600-061
600-057
A30199
A31189
ACDBS100
AXCL0Z
Note: the banding tool is to be used with screened cables to ensure a
good ground contact.
DRV Complete workstation for F7 fibre optic contact
Description
Comprehensive range of tools for terminating both single-
mode and multi-mode fibres. Includes specific tools for F7
fibre optic contacts. Detachable termination case lid for
use as polishing platform during field termination.
Rugged but aesthetically pleasing termination case which
is ideal for field use or in-house terminations. Curing oven
and inspection microscope should be ordered separately.
Part number
DRV.91.CF7.PN
Note: See details in F7 catalogue.
DPE Crimping tool for F7 fibre optic contact
3.1
Description
Crimping tool for capturing KEVLAR® strand on contact body.
Part number
DPE.99.003.1K 1)
Note: 1) Included in the LEMO F7 workstation.
WST Epoxy curing oven
Description
Oven for assisting in curing epoxy.
Part number
Voltage
WST.FR.220.VA
WST.FR.110.VA
220 volts
110 volts
DCS Polishing tool for fibre optic contacts
Description
Precision tool for polishing terminated fibre optic contacts
with 1.25 mm ferrule.
Part number
DCS.91.D01.LC 1)
Note: 1) Included in the LEMO F7 workstation.
32
www.lemo.com
®
®
WST Fibre Inspection Microscope
Description
Microscope to assist in viewing termination operations
and verifying fibre end finish. Zoom with 200 ➞ 400 x
magnification. See adaptor on page 33.
Part number
WST.FB.G00.301
DCS Microscope adaptor for fibre optic contacts
Description
Adaptor for final inspection of fibre optic contacts with 1.25
mm ferrule.
To be used with microscope WST.FB.G00.301.
Part number
DCS.91.G90.6E125 1)
Note: 1) Included in the LEMO F7 workstation.
DCS F7 contact alignment device tool
Description
Simple tool with two threaded end for installation/extraction
of the F7 contact alignment device.
Part number
DCS.F7.035.PN 1)
Note: 1) Included in the LEMO F7 workstation.
Panel Cut-out
Panel cut-outs
Dimensions (mm)
Series
Models
A
B
–
L
H
–
EG●-EE●-EH●-PE●-HE●
ED●-PB●
EC●
FF
7.1
11.5
L
–
EE●
EE●
EE●
EE●
–
EH●
HE●
HE●
HE●
HE●
HE●
HE●
HE●
HE●
PE●
PE●
PE●
PE●
PE●
PE●
PE●
PE●
FF
0F
1F
2F
3F
4F
LF
5F
7.1
6.5 11.5
9.1 16.0
–
–
–
–
–
–
–
L
EH●
EH●
EH●
EH●
EH●
EH●
EH●
10.1
13.1 11.6 20.0
16.1 14.6 23.0
18.2 16.6 25.0
24.2 22.2 32.0
27.2 25.1 35.0
33.2 31.2 41.0
B + 0.1
0
EC●
–
–
–
L
EG●
0F
1F
2F
3F
9.1
8.3 13.5
–
–
–
–
EG●
EG●
EG●
ø B + 0.1
12.1 10.6 17.0
15.1 13.6 21.5
18.1 16.6 27.0
0
ED●
1F
6.2
3.5 15.0 19.3
PB●
PB●
PB●
PB●
PB●
PB●
0F
1F
2F
3F
4F
5F
11.1
13.1
16.1
17.6
23.2
32.3
3.2 16.0 21.4
3.2 16.0 21.4
3.2 19.0 25.9
3.2 21.0 29.0
3.2 27.0 32.0
3.2 34.0 38.2
Mounting nut torque
Series
Torque (Nm)
Series
Torque (Nm)
FF
0F
1F
2F
0.25
1.00
1.50
2.00
3F
4F
LF
5F
2.50
5.00
6.00
8.00
www.lemo.com
33
®
®
PCB drilling pattern
Fixed socket with straight print contact
FF.303
FF.304
0F.302
0F.303
0F.304
4 x ø 1 +0.1
4 x ø 1 +0.1
4 x ø 1 +0.1
4 x ø 1 +0.1
4 x ø 1 +0.1
0
0
0
0
0
3 x ø 0.6 +0.1
4 x ø 0.6 +0.1
3 x ø 0.6 +0.1
4 x ø 0.6 +0.1
0
2 x ø 0.6 +0.1
0
0
0
0
0F.305
1F.303
1F.305
1F.307
1F.308
4 x ø 1 +0.1
4 x ø 1 +0.1
4 x ø 1 +0.1
4 x ø 1 +0.1
4 x ø 1 +0.1
0
0
0
0
0
5 x ø 0.6 +0.1
8 x ø 0.6 +0.1
0
3 x ø 0.6 +0.1
5 x ø 0.6 +0.1
7 x ø 0.6 +0.1
0
0
0
0
2F.308
2F.310
2F.312
2F.319
4 x ø 1 +0.1
4 x ø 1 +0.1
0
4 x ø 1 +0.1
22°30'
15°
4 x ø 1 +0.1
0
0
22°30'
0
8 x ø 0.6 +0.1
10 x ø 0.6 +0.1
12 x ø 0.6 +0.1
19 x ø 0.6 +0.1
0
0
0
0
3F.322
3F.330
4F.340
22°30'
4 x ø 1 +0.1
4 x ø 1 +0.1
0
4 x ø 1 +0.1
11°15'
0
12°52'
0
40 x ø 0.6 +0.1
2.6
30 x ø 0.6 +0.1
22 x ø 0.6 +0.1
0
0
0
LF.368
5F.350
5F.355
6°40’
9°
4 x ø 1 +0.1
7°50’
4 x ø 1 +0.1
7°30’
0
0
13°51’
4 x ø 1 +0.1
51°25’30’’
0
55 x ø 0.8 +0.1
50 x ø 0.8 +0.1
0
0
68 x ø 0.8 +0.1
0
5F.364
5F.366
4 x ø 1 +0.1
4 x ø 1 +0.1
6°55'30''
6°55'30''
0
0
64 x ø 0.8 +0.1
66 x ø 0.8 +0.1
0
0
34
www.lemo.com
®
®
Fixed socket with elbow print contact
A
A
0F.302
1F.303
2F.308
0F.303
1F.305
2F.310
0F.304
1F.307
2F.312
0F.305
1F.308
2F.319
ø 0.7
ø 0.7
ø 0.7
5
2
4
3
1
3
2
4
1
3
2
1
1
2
2.54
2.54 2.54
2.54
2.54
ø 0.9
5
2
5
7
6
4
3
6
1
4
3
5
4
1
7
2
1
2
8
3
3
2
1
2.54 2.54
2.54 2.54
2.54 2.54
2.54
7
6
10
11
9
8
7
3
6
7
6
8
8
1
5
8
1
12
9
11
10
3
5
4
12
18
14
3
17
15
4
7
6
1
2
5
4
9
2
10
3
13
2
19
16
5
4
1
2
2.54 2.54
2.54 2.54 2.54
1.27
2.54 2.54 2.54
www.lemo.com
35
®
®
36
www.lemo.com
®
®
Technical characteristics
Outer shell
Mechanical latching characteristics
Latch sleeve in special bronze/brass
Series
Force
(N)
0F 1F 2F 3F 4F LF 5F
Fv
Fd
Fa
10 11 20 18 23 40 50
11 13 29 20 25 40 55
160 120 170 210 180 250 400
Fv
Fd
Fa
Latch sleeve in Beryllium copper
Series
Force
(N)
FF 0F 1F 2F 3F
Fv
Fd
Fa
16 22 21 29 34
20 21 23 33 17
110 300 250 420 400
Notes: forces were measured on outer shells not fitted with contacts.
1N = 0.102 kg.
1N = 0.2248 pounds force
F : average latching force.
v
F : average unmating force with axial pull on
d
the outer shell.
F : average pull-out force with axial pull on the back shell.
a
Insulator
Plastic material used by LEMO for manufacturing insula-
tors is selected according to the electric and thermal pro-
perties required for the various connector types. Charac-
teristics examined for the two connector types are:
– Dielectric strength
PEEK is selected as it provides all the required characte-
ristics for multipole connectors.
Radiation resistance
– Comparative tracking index
PEEK
– Surface and volume resistivity
– Continuous service temperature
– Water absorption
rads
103
104
102
105
103
106
104
107
105
108
106
109
107
1010
108
– Radiation resistance
Gray (Gy) 101
– Flammability rating
Radiation dose γ
– Resistance to hydrocarbon.
Damage
Minimum to slight (almost available usable)
Slight to medium (often satisfactory)
Medium to serious (not usable)
Mechanical and electrical properties
Mechanical characteristics of thermoplastics, such as
PEEK, are improved by the addition of glass fibres. By
adding glass fibres in the resin the performance of this
material (mechanical strength and radiation resistance) is
enhanced and water absorption rate is reduced. From an
electric point of view, the addition of glass fibres improves
dielectric strength.
Note: technical data in this chapter provide general information on plas-
tics used by LEMO as electrical insulators. LEMO reserves the right to
propose new materials with better technical characteristics, and to with-
draw, without notice, any material mentioned in the present catalogue or
any other publications edited by LEMO S.A. and/or its subsidiaries.
LEMO SA and its subsidiaries use only plastic granules, powder or bars
supplied by specialized companies, and thus cannot in any case take
responsibility with regard to this material.
www.lemo.com
37
®
®
Technical characteristics of plastic materials
Type
Norme
Units
PEEK
Silicone
FPM/FKM
Epoxy
Density
ASTM D 792
–
1.3-1.4
92-142
170
~1.2
> 9
–
~1.9
> 12
–
1.58
16
Tensile strength (at 23°C)
Flexurale strength (at 23°C)
Dielectric strength
ASTM D 638/ ISO R527
ASTM D 790/ ISO R178
ASTM D 149/IEC 60243
ASTM D 257/IEC 60093
ASTM D 257
MPa
MPA
kV/mm
24
19-25
1016
1015
18-30
1014
–
–
–
15
1014
Volume resistivity at 50% HR and 23°C
Surface resistivity
Ω
l
cm
Ω
–
–
–
Thermal conductivity
ASTM C 177
W/K
l
m
0.25
–
0.8
Comparative tracking index
Dielectric constant (106 Hz)
Dissipation factor (106 Hz)
Maximum continuous service temperature
Minimum continuous service temperature
Maximum short-time service temperature
Water absorption in 24h at 23°C
Radiation resistance
IEC 60112
V
CTI 150
3.2-3.5
< 0.005
250
–
–
CTI>600
–
ASTM D 150/IEC 60250
ASTM D 150/IEC 60250
UL 746
–
–
–
–
–
–
–
°C
°C
°C
%
200
-50
> 250
–
200
-20
300
–
80
UL 746
-50
-20
120
0.25
2x106
V-0/4
–
300
ASTM D 570/ISO R62A
–
< 0.3
107
Gy1)
105
8x104
Flammability rating
ASTM D 635/UL 94
–
V-0/1.5
–
–
Notes: 1) 1 Gy (Gray) = 100 rad
ASTM = American Society for Testing Material
ISO = International Standards Organisation
UL
IEC
= Underwriters Laboratories
= International Electrotechnical Commission
Electrical contact
Technical description
The secure reliable electromechanical connection achie-
ved with LEMO female cylindrical contacts is mainly due
to two important design features:
1. Prod proof entry on the mating side which ensures
perfect concentric mating even with carelessly han-
dled connectors.
2. The pressure spring, with good elasticity, maintains a
constant even force on the male contact when mated.
The leading edge of the pressure spring preserves the
surface treatment (gold-plated) and prevents undue
wear.
Contact material and treatment
LEMO female contacts are made of bronze beryllium
(QQ-C-530) or bronze (UNS C 54400). These materials are
chosen because of their high modulus of elasticity, their
excellent electrical conductivity and a high mechanical
strength. LEMO male print contacts are made of brass
(UNS C 38500). Male crimp contacts are made of brass
(UNS C 34500) or annealed brass (UNS C 38500) with
optimum hardness (HV) for crimping onto the wire.
Surf. treatment (µm)
Material (standard)
Type
Male crimp
Male print
Cu
Ni
Au1)
Brass (UNS C 34500)
Brass (UNS C 38500)
Brass (UNS C 38500)
0.5
3
1.0
Female crimp
Female print
Bronze (UNS C 54400)
Cu-Be (FS QQ-C-530)
0.5
3
1.5
Cu-Be (FS QQ-C-530)
Stainless steel
–
–
–
–
–
Clips
Au
Ni
33)
Wire2)
Brass
Notes: the standard surface treatment are as follows:
– nickel: SAE AMS QQ N 290 or MIL DTL 32119
– gold: ISO 27874.
Cu
1) minimum value
Bronze
or brass
2) for elbow print contacts
3) treatment completed by 6 µm Sn-Pb tin-plating
38
www.lemo.com
®
®
Thickness comparison between the outside and the inside of female contacts
Gold thickness
female
P
Contact
ø A
(mm)
2.5
male
(µm)
outside
inside
(%)
(µm)
0.5
0.7
0.9
1.3
1.0
1.0
1.0
1.0
1.5
1.5
1.5
1.5
65
70
75
75
P
2.5
Note: P = inspection point
Crimp contacts
Advantages of crimping
The square form crimp method is used (MIL-C-22520F,
class I, type 2) photo 1 for unipole contacts.
– practical, quick contact fixing outside the insulator
– possible use at high temperature
– no risk of heating the insulator during the conduc-
tor-contact fixing
For multipole contacts the standard four identer crimp
method is used, (MIL-C-22520F, class I, type 1), photo 2.
The crimp method requires a controlled compression to
obtain a symmetrical deformation of the conductor strand
and of the contact material. The radial hole in the side
of the contact makes it possible to check whether the
conductor is correctly positioned within the contact. A
good crimping is characterized by only slightly reduced
conductor section and practically no gap.
– high tensile strength
Crimp contacts are available in standard version (form 1)
for mounting maximum size conductors.
For some dimensions, these crimp contacts can be pro-
duced with reduced crimp barrels (form 2) for mounting
reduced size conductors.
For optimum crimping of bronze or brass contacts they
are annealed to relieve internal stress and reduce material
hardening during the crimping process.
1
2
3
Only the crimping zone is annealed with the help of
an induction heating machine designed by the LEMO
Research and Development Department (see photo 3).
Test voltage
Test voltage (Ue):
(measured according to the IEC 60512-2 test 4a standard)
Voltage values are given in the table on insulator types
for each series.
They correspond with values measured at sea level.
They are adapted to all applications up to an altitude of
2000 m.
It corresponds to 75% of the mean breakdown voltage.
Test voltage is applied at 500 V/s and the test duration is
1 minute.
In case a device is used at a higher altitude, air clearance
between live parts has to be multiplied by the following
coefficients.
This test has been carried out with a mated plug and
socket, with power supply only on the plug end.
It means also that test voltage has to be divided by this
coefficient
The operating voltage value definition is at the entire
responsibility of the customer who defines this value
according to the safety factors that they apply to their
equipment and system.
altitude (m)
coefficient
2000
3000
4000
5000
1.00
1.14
1.29
1.48
Caution:
For a number of applications, safety requirements
for electrical appliances are more severe with regard
to operating voltage.
In such cases operating voltage is defined according
to creepage distance and air clearance) between live
parts.
Please consult us for the choice of a connector
by indicating the safety standard to be met by the
product.
www.lemo.com
39
®
®
Rated current
(measured according to IEC 60512-3 test 5a)
For connectors with PEEK insulator, maximum admissible
current will follow the curve below depending on the ope-
rating temperature T.
The specified rated current can be applied simultaneously
to all the contacts.
It corresponds with an average temperature rise of 40°C
of the connector.
Rated current (A)
The current values are indicated in the table of insulator
types in each series.
For use at higher temperatures acceptable rated current
will be lower. It tends towards zero as the material is used
at the maximum operating temperature accepted for the
insulator.
100%
75%
50%
25%
In most case the current depend on the conductor
dimension (see table on page 43) or on the printed circuit
dimension.
T (°C)
0
50
100
150
200
250
Caution: In general, connectors should not be unma-
ted while live.
40
www.lemo.com
®
®
Assembly instructions
Assembly instructions for plugs and sockets
3
3
3
2
2
1
1
FGN
PHN
PEN
1. Cable preparation
Series
L
S
9
T
0.5
L
First place the heatshrink boot ➀
over the cable. Strip the cable accor-
ding to dimensions of the table, then
widen the shield.
0.2
1
T
FF
14
3
4
0F-5F
20 15
0.5
S
2. Cable termination
Crimp
Crimp
2
2
2.1 With shielded cables, widen and pull the shield all the way to the back.
Fix the appropriate positioner onto the crimping tool and set the selec-
tor to the number corresponding to the AWG of the conductor used as
indicated on the positioner label. Fit the conductor into the contact ➁;
make sure it is visible through the contact’s inspection hole.
Slide the conductor-contact assembly into the open crimping tool;
make sure that the contact is pushed fully into the positioner.
Close the tool.
Remove from crimping tool and check that conductor is secure in
contact and shows in inspection hole.
2.2 Arrange the conductor-contact assemblies according to the mar-
kings, into the rear cable seal. Push them deeply into the insulator,
using tweezers if necessary; check that all the contacts are correctly
located in the insulator: 1) by verifying the alignment of the contacts
at the front of the insulator and 2) by gently pulling on each conduc-
tor. Verification should also be made using the appropriate retention
testing tool.
3
3
With FF series the rear cable seal can be replaced with a silicone
RTV compound that is filled on the rear of the connector once the
contacts are correctly installed.
2.3 Bring the shield around the rear of connector. Secure it with a band-it
tie-wrap (not furnished) to fix the shield in place.
Cut off the possible shield surplus.
Tie wrap
Tie wrap
2.4 Put the heatshrink boot in place and heat gently until it retracts.
Heat
Heat
www.lemo.com
41
®
®
Technical tables
Table of American Wire Gauge
Table of wire gauges according to IEC-228 standard
Construction
ø wire max
Wire section
Conductor no
x Ø (mm)
Max Ø
(mm)
Max Ø
(in)
Section
(mm2)
Section
(sq in)
AWG
Strand AWG/
(mm)
(in)
(mm2)
(sq in)
nb
strand
7.50
6.10
6.00
4.90
4.50
4.70
3.95
3.60
3.70
3.15
2.76
2.80
2.58
2.25
2.15
2.04
1.78
1.60
1.56
1.40
1.35
1.29
1.15
1.20
1.15
1.00
0.95
0.90
0.80
0.75
0.60
0.75
0.65
0.50
0.40
0.40
0.40
0.295
0.240
0.236
0.192
0.177
0.155
0.155
0.141
0.145
0.124
0.108
0.110
0.098
0.082
0.084
0.080
0.070
0.062
0.061
0.055
0.053
0.050
0.045
0.047
0.045
0.039
0.037
0.035
0.031
0.029
0.023
0.029
0.023
0.019
0.015
0.015
0.015
25.00
25.00
16.00
16.00
16.00
10.00
10.00
10.00
6.00
6.00
6.00
4.00
4.00
4.00
2.50
2.50
2.50
1.50
1.50
1.50
1.00
1.00
1.00
0.75
0.75
0.75
0.50
0.50
0.50
0.34
0.28
0.25
0.22
0.14
0.11
0.09
0.09
0.0387
0.0387
0.0248
0.0248
0.0248
0.0155
0.0155
0.0155
0.0093
0.0093
0.0093
0.0062
0.0062
0.0062
0.0038
0.0038
0.0038
0.0023
0.0023
0.0023
0.0015
0.0015
0.0015
0.0011
0.0011
0.0011
7.7x10-4
7.7x10-4
7.7x10-4
5.2x10-4
4.3x10-4
3.8x10-4
3.4x10-4
2.1x10-4
1.7x10-4
1.3x10-4
1.3x10-4
196x0.40
7x2.14
125x0.40
7x1.72
1x4.50
80x0.40
7x1.38
1x3.60
84x0.30
7x1.50
1x2.76
56x0.30
7x0.86
1x2.25
50x0.25
7x0.68
1x1.78
30x0.25
7x0.52
1x1.4
4
133
133
168
133
105
37
1
25
27
30
29
30
26
10
30
28
25
20
12
30
27
22
14
34
30
29
24
16
36
34
30
30
26
18
36
32
30
28
20
34
30
22
40
36
32
24
38
34
26
40
36
28
38
30
40
32
34
36
38
40
6.9596
5.5118
4.4450
4.3942
3.3020
2.9210
2.6162
2.5146
2.3114
2.3622
2.5400
2.0828
2.0574
1.8542
2.0828
1.6510
1.5748
1.5748
1.4986
1.5494
1.3208
1.2700
1.2700
1.3208
1.2954
1.2700
1.0414
1.0160
1.0414
1.0160
0.9906
0.8382
0.8382
0.7874
0.6604
0.6604
0.6858
0.6350
0.5588
0.5588
0.5080
0.4318
0.4318
0.4064
0.3302
0.3302
0.2794
0.2794
0.2286
0.1693
0.127
0.274
0.217
0.175
0.173
0.13
21.5925
13.5885
8.5127
8.6053
5.3204
4.7397
5.2614
3.2936
2.9765
3.0847
3.6321
3.3081
2.0775
1.9413
2.2704
2.0820
1.3072
1.3174
1.2293
1.4330
1.3076
0.8234
0.8447
0.9627
0.8107
0.8967
0.8229
0.5320
0.6162
0.5067
0.5631
0.5189
0.3821
0.3547
0.3243
0.2045
0.2407
0.2270
0.2047
0.1540
0.1408
0.1281
0.0925
0.0887
0.0804
0.0568
0.0507
0.0341
0.0324
0.0201
0.0127
0.0081
0.0049
0.0335
0.0211
0.0132
0.0133
0.0082
0.0073
0.0082
0.0051
0.0046
0.0048
0.0056
0.0051
0.0032
0.0030
0.0035
0.0032
0.0020
0.0020
0.0019
0.0022
0.0020
0.0013
0.0013
0.0015
0.0013
0.0014
0.0013
8.2x10-4
0.0010
7.9x10-4
8.7x10-4
8.0x10-4
5.9x10-4
5.5x10-4
5.0x10-4
3.2x10-4
3.7x10-4
3.5x10-4
3.2x10-4
2.4x10-4
2.2x10-4
2.0x10-4
1.4x10-4
1.4x10-4
1.2x10-4
8.8x10-5
7.9x10-5
5.3x10-5
5.0x10-5
3.1x10-5
2.0x10-5
1.3x10-5
7.5x10-6
6
8
8
10
10
0.115
0.103
0.099
0.091
0.093
0.1
10
12
65
37
19
7
12
12
12 1)
12
1
0.082
0.081
0.073
0.082
0.065
0.062
0.062
0.059
0.061
0.052
0.05
14
41
19
7
14
14 1)
14
16 1)
16
1
65
26
19
7
16
16 1)
32x0.20
7x0.43
1x1.15
42x0.15
28x0.20
1x1.0
16
1
18 1)
18 1)
18
65
42
19
16
7
0.05
0.052
0.051
0.05
18
18
28x0.15
16x0.20
1x0.80
7x0.25
1x0.60
14x0.15
7x0.20
18x0.10
14x0.10
21x0.07
14x0.10
18
20 1)
1
0.041
0.04
42
19
10
7
20
0.041
0.04
20
20
0.039
0.033
0.033
0.031
0.026
0.026
0.027
0.025
0.022
0.022
0.02
20
1
22
19
7
22
22
24 1)
1
42
19
7
24
24
24
1
26
19
7
26
26
28 1)
1
0.017
0.017
0.016
0.013
0.013
0.011
0.011
0.009
0.007
0.005
0.004
0.003
19
7
28
28
1
30
7
30
1
32
7
32
1
34
1
36
1
38
1
0.1016
0.078
40
1
Note: 1) not included in the standard
42
www.lemo.com
®
®
Maximum current rating for conductor
Maximum current on insulated conductors up to an ambiant temperature of 30° C (from VDE 0100, parts 430 and 532 as
well as other VDE regulations).
Nominal
section
mm2
Group 2
Intens.
max. A
Group 3
Intens.
max. A
0.08
0.14
0.25
0.34
0.50
0.75
1.00
1.50
2.50
1.0
2.0
1.5
3.0
4.0
5.0
6.0
8.0
9.0
12.0
15.0
19.0
24.0
32.0
12.0
15.0
18.0
26.0
Group 2 Multi-conductor, e. g. solid cable under sheath, shielded cable, lead-sheath cables, …
Group 3 Single conductor and single conductor cable laid on open air in a way to leave at least a
space between them equal to their diameter
Conversion of some units:
millimeters into inches:
1 mm = 0.0394 in
1 in = 25.4 mm
1 cm = 0.0328 ft
1 ft = 30.48 cm
inches into millimeters:
centimeters into feet:
feet (12 in) into centimeters:
square centimeters into square inches:
square inches into square centimeters:
bar into pounds per square inch:
bar into Pascal:
2
1 cm = 0.155 sq in
2
1 sq in = 6.4516 cm
1 bar = 14.51 psi
5
1 bar = 10 Pa
●
°C into °F:
°F = °C 1.8 + 32
●
●
newtonmeter (Nm) into inch pound (in lb)
1 Nm = 8.85 in lb
-1
-1
-1
-1
●
●
●
●
●
●
●
●
mbar l s into Torr l s
1 mbar l s = 1.33 Torr l s
www.lemo.com
43
®
®
Product safety notice
PLEASE READ AND FOLLOW ALL INSTUCTIONS CAREFULLY AND CONSULT ALL RELEVENT NATIONAL AND
INTERNATIONAL SAFETY REGULATIONS FOR YOUR APPLICATION.
IMPROPER HANDLING, CABLE ASSEMBLY, OR WRONG USE OF CONNECTORS CAN RESULT IN HAZARDOUS
SITUATIONS.
1. SHOCK AND FIRE HAZARD
Incorrect wiring, the use of damaged components, presence of foreign objects (such as metal debris), and / or residue
(such as cleaning fluids), can result in short circuits, overheating, and / or risk of electric shock.
Mated components should never be disconnected while live as this may result in an exposed electric arc and local
overheating, resulting in possible damage to components.
2. HANDLING
Connectors and their components should be visually inspected for damage prior to installation and assembly. Suspect
components should be rejected or returned to the factory for verification.
Connector assembly and installation should only be carried out by properly trained personnel. Proper tools must be used
during installation and / or assembly in order to obtain safe and reliable performance.
3. USE
Connectors with exposed contacts should never be live (or on the current supply side of a circuit). Under general
conditions voltages above 30 VAC and 42 VDC are considered hazardous and proper measures should be taken to
eliminate all risk of transmission of such voltages to any exposed metal part of the connector.
4. TEST AND OPERATING VOLTAGES
The maximum admissible operating voltage depends upon the national or international standards in force for the
application in question. Air and creepage distances impact the operating voltage; reference values are indicated in the
catalog however these may be influenced by PC board design and / or wiring harnesses.
The test voltage indicated in the catalog is 75% of the mean breakdown voltage; the test is applied at 500 V/s and the
test duration is 1 minute.
5. CE MARKING
CE marking
means that the appliance or equipment bearing it complies with the protection requirements of one or
several European safety directives.
CE marking
applies to complete products or equipment, but not to electromechanical components, such as
connectors.
6. PRODUCT IMPROVEMENTS
The LEMO Group reserves the right to modify and improve to our products or specifications without providing prior
notification.
7.
WARNING (Prop 65 State of California)
Proposition 65 requires businesses to provide warnings to Californians about significant exposures to chemicals that
cause cancer, birth defects or other reproductive harm. LEMO products are exempt from proposition 65 warnings
because they are manufactured, marketed, and sold solely for commercial and industrial use. For further information,
please visit https://www.lemo.com/quality/LEMO-Prop-65-compliance-declaration.pdf.
Disclaimers
LEMO works constantly to improve the quality of its products; the information and illustrations figuring in this document may
therefore vary and are not binding. In any case, LEMO makes no specific warranty of merchantability, fitness for a partic-
ular purpose, third party components as such or included in assembly, non-infringement, title, accuracy, completeness, or
security. The user is fully responsible for his products and applications using LEMO component.
In no event shall LEMO, its affiliates, officers, agents or employees be liable for any incidental, indirect, special or conse-
quential damages in connection with the products or services provided by LEMO, including (without limitation) loss of profits
or revenues, interruption of business, loss of use of the products or any associated equipment, materials, components or
products, damages to associated equipment or in combination with other components, materials.
Reproduction of significant portions of LEMO information in LEMO data books or data sheets is permissible only if repro-
duction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. LEMO is
not responsible or liable for such altered documentation. Information of third parties may be subject to additional restrictions.
44
www.lemo.com
LEMO complete product range
3K.
93C
B
S
K
E
F
00 01 0A 3T 4A 4M
1D
Y
05 5G 2G 2C
L
H
M
R
N
03
V
W
T7
P
D
K/S 01 DIN
Unipole
Multipole
•
Coaxial 50 Ω
Coaxial 75 Ω
Multi Coaxial
Mixed Coax + LV
Triaxial 50 Ω
Triaxial 75 Ω
Mixed Triax + LV
Quadrax
High Voltage
Multi High Voltage
Mixed HV + LV
Fibre Optic
Multi Fibre Optic
Mixed FO + LV
Thermocouple
Fluidic
•
•
Multi Fluidic
Mixed Fluidic + LV
Most frequently used in darker colour
included in this catalogue
•
B Series Keyed
S Series
K Series Keyed
E Series
4M Series Keyed
2C Series
F Series Keyed
00 Series
1D Series
H Series
01 Series
0A Series
3T Series
4A Series
3K.93C Series Keyed
L Series Keyed
W Series Keyed
VAA Series
Y Series
M Series Keyed
K/S Series Keyed
TAA Series
05 Series
5G Series Keyed
N Series Keyed
REDEL P Series Keyed
2G Series Keyed
03 Series Keyed
REDEL D Series
R Series Keyed
V Series
Cable assembly
REDEL T7 Series
01 Series Keyed
SAA Series
No reproduction or use without express permission of editorial or pictorial content, in any manner.
LEMO SA reserves the right to modify and improve specifications, at all times, without any notification.
LEMO HEADQUARTERS
SWITZERLAND
LEMO SA
Chemin des Champs-Courbes 28 - P.O. Box 194 - CH-1024 Ecublens
Tel. +41 21 695 16 00 - e-mail: info@lemo.com
LEMO SUBSIDIARIES
AUSTRIA
NETHERLANDS / BELGIUM
LEMO Connectors Nederland B.V.
Jacques Meuwissenweg 6
2031 AD Haarlem
LEMO Elektronik GesmbH
Lemböckgasse 49/E6-3
1230 Wien
Tel: +43 1 914 23 20 0
Fax:+43 1 914 23 20 11
salesAT@lemo.com
Tel. +31 23 206 07 01
info-nl@lemo.com
NORWAY / ICELAND
LEMO Norway A/S
Soerumsandvegen 69,
1920 Soerumsand
Tel: +47 22 91 70 40
Fax: +47 22 91 70 41
info-no@lemo.com
BRAZIL
LEMO Latin America Ltda
Av. Dr. Adhemar de Barros,
566 – Sala 1407, Vila Adyana
CEP: 12245-011
São José dos Campos - SP - Brazil
Tel: +55 11 94242 4293
info-la@lemo.com
SINGAPORE
LEMO Asia Pte Ltd
4 Leng Kee Road,
#06-09 SiS Building
Singapore 159088
Tel: +65 6476 0672
Fax: +65 6474 0672
sg.sales@lemo.com
CANADA
LEMO Canada Inc
44 East Beaver Creek Road, unit 20
Richmond Hill, Ontario L4B 1G8
Tel: +1 905 889 56 78
Fax: +1 905 889 49 70
info-canada@lemo.com
SPAIN / PORTUGAL
IBERLEMO SAU
Brasil, 45, 08402 Granollers
Barcelona
Tel: +34 93 860 44 20
Fax: +34 93 879 10 77
info-es@lemo.com
CHINA / HONG KONG
LEMO Electronics (Shanghai) Co., Ltd
First Floor, Block E,
18 Jindian Road, Pudong
Shanghai, China, 201206
Tel: +86 21 5899 7721
Fax: +86 21 5899 7727
cn.sales@lemo.com
SWEDEN / FINLAND
LEMO Nordic AB
Gunnebogatan 30, Box 8201
163 08 Spånga
Tel: +46 8 635 60 60
Fax: +46 8 635 60 61
info-se@lemo.com
DENMARK
LEMO Denmark A/S
Mandal Allé 16A
5500 Middelfart
Tel: +45 45 20 44 00
Fax: +45 45 20 44 01
info-dk@lemo.com
SWITZERLAND
LEMO Verkauf AG
Grundstrasse 22 B,
6343 Rotkreuz
FRANCE
LEMO France Sàrl
24/28 Avenue Graham Bell
Bâtiment Balthus 4
Tel: +41 41 790 49 40
ch.sales@lemo.com
Bussy Saint Georges
77607 Marne la Vallée Cedex 3
Tel: +33 1 60 94 60 94
Fax: +33 1 60 94 60 90
info-fr@lemo.com
TAIWAN
TAOYUAN TAIWAN
Tel: +886 967 132 824
speng@lemo.com
UNITED ARAB EMIRATES
LEMO Middle East Connectors LLC
Concorde Tower 6th Floor,
Dubai Media City, P.O. Box 126732
Dubai, United Arab Emirates
Tel: +971 55 222 36 77
GERMANY
LEMO Elektronik GmbH
Hanns-Schwindt-Str. 6
81829 München
Tel: +49 89 42 77 03
Fax: +49 89 420 21 92
info@lemo.de
info-me@lemo.com
UNITED KINGDOM
HUNGARY
LEMO UK Ltd
REDEL Elektronika Kft
Nagysándor József u. 6-12
1201 Budapest
12-20 North Street, Worthing,
West Sussex, BN11 1DU
Tel: +44 1903 23 45 43
lemouk@lemo.com
Tel: +36 1 421 47 10
Fax: +36 1 421 47 57
info-hu@lemo.com
USA
LEMO USA Inc
ITALY
P.O. Box 2408
LEMO Italia srl
Rohnert Park, CA 94927-2408
Tel: +1 707 578 88 11
+1 800 444 53 66
Fax: +1 707 578 08 69
info-US@lemo.com
Viale Lunigiana 25
20125 Milano
Tel: +39 02 66 71 10 46
Fax: +39 02 37 90 80 46
sales.it@lemo.com
JAPAN
LEMO Japan Ltd
2-7-22, Mita,
Minato-ku, Tokyo, 108-0073
Tel: +81 3 54 46 55 10
Fax: +81 3 54 46 55 11
info-jp@lemo.com
LEMO DISTRIBUTORS
ARGENTINA, AUSTRALIA, BRAZIL, CHILE, COLOMBIA, CZECH REPUBLIC,
GREECE, INDIA, ISRAEL, NEW ZEALAND, PERU, POLAND, RUSSIA,
SOUTH AFRICA, SOUTH KOREA, TURKEY, UKRAINE
www.lemo.com
相关型号:
©2020 ICPDF网 联系我们和版权申明