ER3R-63N3PB [ETC]

SWITCH COMPONENT HANDLE BLACK;
ER3R-63N3PB
型号: ER3R-63N3PB
厂家: ETC    ETC
描述:

SWITCH COMPONENT HANDLE BLACK

文件: 总90页 (文件大小:22439K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Disconnect switches — 11  
Section  
page  
Description  
The power of space  
Compact Circuit Protector disconnect switches  
Compact Circuit Protector Base (CCP2B - CUBEFuse)  
Class CC, UL supplemental and IEC 10x38 (CCP2)  
Accessories for Class CC, UL supp. and IEC 10x38 CCP2  
Multi-wire lug kits  
36-37  
38-42  
43-47  
43  
The BussmannTM series Compact Circuit  
Protector for Class CF CUBEFuseTM  
delivers the smallest footprint compared  
to any Class J disconnect solution —  
requiring up to 51% less space.  
Selector and pistol handles, shafts, NFPA 79 compliant  
handles  
44  
Auxiliary contacts  
PLC fuse monitors  
45  
46-47  
How to order Class CC, UL supplemental and IEC  
10x38 switches  
48-51  
52-53  
Low profile Class CC and G, UL supplemental and  
IEC 10x38 (CCPLP)  
UL 98 fused disconnect switches, 30 to 800 A  
Introduction and agency information  
Product line summary — UL  
54  
55  
30 A Class CC and compact Class J  
30 A standard Class J  
56-57  
58-59  
60-61  
62-63  
64-65  
66-68  
69-70  
60 A compact Class J  
60 A standard Class J  
100 A standard Class J  
200 A and 400 A standard Class J  
600 A standard Class J and 800 A Class L  
UL 98 non-fused disconnect switches, 30 to 1200 A  
Introduction, agency information and IEC product summary  
UL product summary  
71  
72  
30 A, 60 A and 100 A compact  
73-74  
75-76  
77-78  
100 A, 200 A and 400 A standard  
600 A, 800 A, 1000 A and 1200 A standard  
UL 508 non-fused disconnect switches, 16 to 80 A  
Introduction, agency information and IEC product summary  
UL product summary  
Contents  
79  
80  
Section  
page  
Description  
16 A, 25 A, 40 A, 63 A and 80 A  
81-83  
Compact Circuit Protector disconnect switches  
Class CF CUBEFuse up to 100 A (CCP2-CF)  
Class CF CUBEFuse 200 and 400 A (CCP2-CF)  
Accessories for CUBEFuse CCP2  
Multi-wire lug kits  
Enclosed UL 98 and UL 508 disconnect switches  
Introduction and agency information  
Fused UL 98 enclosed disconnects, 30 to 800 A  
Non-fused UL 98 enclosed disconnects, 30 to 1200 A  
Non-fused UL 508 enclosed disconnects, 16 to 80 A  
2-8  
9-12  
13-  
84  
85-86  
87-88  
89-90  
13-14  
Selector and pistol handles, shafts, NFPA 79 compliant  
handles  
15-16  
Flange handle rod and cable operators  
200 and 400 A switch rotary mechanisms  
Auxiliary contacts  
17  
18  
19-20  
21-22  
23-35  
23-30  
32-35  
PLC fuse monitors (up to 100 A switches)  
How to order Class CF switches  
Switches up to 100 A  
200 and 400 A switches  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-1  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Compact Circuit Protector  
UL 98 Class CF disconnect switches from 30 to 400 A  
Class CF CCP contents  
Section page  
30, 60 and 100 amp switches  
Descriptions and specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4  
Catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5  
Terminal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6  
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-8  
200 and 400 A switches  
Descriptions and specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . .9-10  
Catalog numbers and horsepower ratings . . . . . . . . . . . . . . . . . . . . . 10  
Available lugs. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10  
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11-12  
Accessories  
CCP2 switch up to 100 A  
with and without rotary operation mechanisms  
Multi-wire lug kits  
30, 60 and 100 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13  
200 and 400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14  
Handles and shafts  
Selector and pistol handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15  
Handle shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
NFPA 79 compliant handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16  
Flange handle rod and cable operators . . . . . . . . . . . . . . . . . . . . . . . . 17  
200 and 400 A switches  
Front rotary mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Side rotary mechanisms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Terminal shroud kits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Phase barrier kits. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Handle extension. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18  
Auxiliary contacts  
30, 60 and 100 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19  
200 and 400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20  
PLC fuse monitor (30, 60 and 100 A switches). . . . . . . . . . . . . . . .21-22  
How to order  
200 A CCP2 switch  
with and without rotary operation mechanisms  
30 and 60 A switches  
Switch only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23  
Front and right side rotary switches . . . . . . . . . . . . . . . . . . . . . .24-25  
Left side rotary switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26  
100 A switches  
Switch only. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27  
Front and right side rotary switches . . . . . . . . . . . . . . . . . . . . . .28-29  
Left side rotary switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30  
200 and 400 A switches  
200 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32-33  
400 A switches . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34-35  
400 A CCP2 switch  
with and without rotary operation mechanisms  
11-2  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Catalog symbols for 30, 60 and 100 A switches  
Conductors/terminals  
•ꢀ  
75°C Cu, see conductor tables for size, type and torque  
information  
Symbol  
CCP2-(pole)-(amps)CF  
Description  
Switch only  
•ꢀ  
•ꢀ  
Box lug, single/dual conductor  
CCP2R-(pole)-(amps)CF Right front rotary, clockwise operated switch  
Fork terminal suitable for line, load or accessory connection, max.  
30 A suitable for use with:  
CCP2RL-(pole)-(amps)CF Left front rotary, clockwise operated switch  
•ꢀ 10-24 screw for 30 and 60 A switches  
•ꢀ 1/4-28 screw for 100 A switches  
CCP2S-(pole)-(amps)CF  
CCP2SL-(pole)-(amps)CF  
Right side rotary, clockwise operated switch  
Left side rotary, counterclockwise operated  
switch  
•ꢀ  
Multi-wire lug kits — see accessories for details  
Description  
Storage and operating temperature  
The revolutionary, next generation Bussmann™ series Compact  
Circuit Protector (cat. no. CCP2) is a fused UL® 98 branch circuit  
disconnect switch utilizing the UL Class CF time-delay or fast-acting  
CUBEFuse™ with Class J electrical performance. With up to a 51  
percent smaller footprint than a traditional fusible solution, these  
switches provide a high 200 kA SCCR to help improve panel and  
assembly SCCR.  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)*  
* For fuse performance under or above 25°C, consult fuse performance derating  
charts in the Bussmann Division publication no. 3002, titled Selecting Protective  
Devices (SPD)  
Lockout/tagout provisions  
The 35 mm DIN-Rail mount CCP2 is available in a variety of 30,  
60 and 100 amp configurations to meet many application needs  
including rotary operation.  
•ꢀ  
1/4” lock, direct use on switches without rotary mechanisms  
requires a lock with a straight shank of sufficient length to engage  
all poles  
The switch-only versions of the 30, 60 and 100 A disconnects are  
direct, drop-in replacements for the earlier models (noted by a  
catalog number starting “CCP-”). The auxiliary contacts and PLC  
remote fuse indicator are backwards compatible. The multi-wire lug  
kits and terminal shrouds are not.  
Minimum enclosure size per UL 98*  
•ꢀ  
30 and 60 A switch 10”x 8”x 6”(254 x 203 x 152 mm)  
•ꢀ  
100 A switch, 12” x 10” x 6” (305 x 254 x 152 mm)  
Application flexibility is extended with an optional multi-wire lug  
kit, featuring finger-safe shrouds, that provides three (30 and 60 A  
switches) and six (100 A switches) additional wire ports on each pole  
for power distribution applications.  
* Smaller enclosures may be used at the discretion of the user, with adherence to  
NEC minimum wire bend radius requirements.  
Mounting**  
•ꢀ  
35 mm DIN-Rail  
Other accessories include a PLC fuse monitor for open fuse  
indication and NO/NC auxiliary contacts that easily integrate into  
various monitoring systems.  
**Switch is panel mount with flange handle cable operator.  
Local open fuse indication minimum voltage  
Front and side rotary operated versions are easily applied for  
through-the-door or through the left or right side operation to  
enhance safety.  
•ꢀ  
90 Vac, requires an open fuse to be in the CCP2 and the switch in  
the ON position  
Ratings  
Accessories  
•ꢀ  
Volts  
•ꢀ  
Multi-wire lug kits with terminal shrouds  
•ꢀ  
347 Vac (1-pole switches)  
•ꢀ  
Selector and pistol handles for use with rotary operated switches  
•ꢀ  
600 Vac (2- and 3-pole switches)  
•ꢀ  
8 mm shafts for use with selector and pistol handles  
•ꢀ  
125 Vdc*  
•ꢀ  
Auxiliary contacts  
•ꢀ  
Amps  
•ꢀ  
PLC fuse monitor  
•ꢀ  
30 A  
•ꢀ  
NFPA 79 compliant handle  
•ꢀ  
60 A  
•ꢀ  
Flange handle rod and cable operators  
•ꢀ  
100 A  
•ꢀ  
SCCR  
•ꢀ  
200 kA RMS Sym.  
•ꢀ  
100 kA DC  
Poles  
•ꢀ  
1-, 2- and 3-poles catalog number dependent  
* Switch amp rating and installed fuse amp rating dependent, see catalog number  
table for details.  
Agency information  
•ꢀ  
UL 98 Listed, Guide WHTY, File E302370  
•ꢀ  
cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7,  
File E302370  
•ꢀ  
RoHS compliant  
•ꢀ  
CE  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-3  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Features  
•ꢀ  
Uses UL Class CF time-delay or fast-acting CUBEFuse with Class  
J electrical performance  
•ꢀ  
Extremely compact design at 25.4 mm (1 inch) wide per pole  
•ꢀ  
Amp rating rejection disconnects will not accept a CUBEFuse amp  
rating greater than switch rating  
•ꢀ  
High 200 kA short-circuit current rating  
•ꢀ  
Disconnect rated to provide means for load isolation  
•ꢀ  
Full voltage rated at 347 Vac (1-pole switches) and 600 Vac (2- and  
3-pole switches)  
•ꢀ  
125 Vdc* rated to meet specialized applications  
•ꢀ  
UL 98 Listed and suitable for branch circuit disconnect and branch  
circuit protection with installed fuses  
•ꢀ  
Horsepower rated  
•ꢀ  
Open fuse indication:  
•ꢀ Local open fuse indication light standard on each pole  
•ꢀ Optional PLC fuse monitor for wired remote open fuse  
indication by signaling a PLC and opening a contactor to  
de-energize all phases, if required  
•ꢀ  
Additional open fuse indication can be provided by the indicating  
time-delay CUBEFuse (6 to 100 A)  
Finger-safe construction with 10 AWG (6 mm2) wire or larger  
•ꢀ  
•ꢀ  
Built-in switch interlock prohibits removing or installing the fuse  
while in the ON position  
•ꢀ  
Padlockable for lockout/tagout procedures with a 1/4” lock  
Right front rotary operated CCP2 switch with PLC fuse monitor.  
•ꢀ  
Rotary operated versions provide for through-the-door and  
through-the-side operation flexibility and enhanced safety with:  
•ꢀ Right or left front operation  
•ꢀ Right or left side operation  
•ꢀ  
Optional selector and pistol handles, and shafts available for use  
with rotary operated versions  
Rotary operating versions  
•ꢀ  
Multi-wire lug kits with terminal shrouds allow for power  
distribution to multiple loads. Each lug has three (30 and 60 A  
switches) or six (100 A switches) ports rated for single and dual  
wires (see lug kits in accessories for details).  
* Switch amp rating and installed fuse amp rating dependent, see catalog number  
table for details.  
Switch handle (ganged on 2- and  
3-pole versions)  
Open fuse  
indicating light  
Left front  
Right front  
Fuse holder  
Uses clockwise handles  
Uses clockwise handles  
Fork terminal  
Box lug terminal  
1/4” Lockout/  
tagout provision  
Left side  
Right side  
Uses counterclockwise handles  
Uses clockwise handles  
11-4  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
30, 60 and 100 A switch catalog numbers  
Max Hp rating (Vac)  
Catalog no.  
Poles Description/switch operation  
Volts  
SCCR  
120  
240  
480  
600  
30 amp switches  
CCP2-1-30CF  
1
2
3
2
3
2
3
2
3
2
3
347 Vac/125 Vdc  
600 Vac/125 Vdc  
600 Vac  
1-1/2  
CCP2-2-30CF  
Switch only  
3
5
3
5
3
5
3
5
3
5
15  
15  
15  
15  
15  
10  
10  
10  
10  
10  
CCP2-3-30CF  
CCP2R-2-30CF  
CCP2R-3-30CF  
CCP2RL-2-30CF  
CCP2RL-3-30CF  
CCP2S-2-30CF  
CCP2S-3-30CF  
CCP2SL-2-30CF  
CCP2SL-3-30CF  
60 amp switches  
CCP2-1-60CF  
600 Vac/125 Vdc  
600 Vac  
Right front rotary, clockwise  
Left front rotary, clockwise  
Right side rotary, clockwise  
Left side rotary, counterclockwise  
200 kA AC  
100 kA DC  
600 Vac/125 Vdc  
600 Vac  
600 Vac/125 Vdc  
600 Vac  
600 Vac/125 Vdc  
600 Vac  
1
2
3
2
3
2
3
2
3
2
3
347 Vac/125 Vdc*  
600 Vac/125 Vdc*  
600 Vac  
3
10  
10  
10  
10  
10  
CCP2-2-60CF  
Switch only  
7-1/2  
CCP2-3-60CF  
7-1/2 20  
7-1/2  
7-1/2 20  
7-1/2  
7-1/2 20  
7-1/2  
7-1/2 20  
7-1/2  
7-1/2 20  
CCP2R-2-60CF  
CCP2R-3-60CF  
CCP2RL-2-60CF  
CCP2RL-3-60CF  
CCP2S-2-60CF  
CCP2S-3-60CF  
CCP2SL-2-60CF  
CCP2SL-3-60CF  
100 amp switches  
CCP2-1-100CF  
CCP2-2-100CF  
CCP2-3-100CF  
CCP2R-2-100CF  
CCP2R-3-100CF  
CCP2RL-2-100CF  
CCP2RL-3-100CF  
CCP2S-2-100CF  
CCP2S-3-100CF  
CCP2SL-2-100CF  
CCP2SL-3-100CF  
600 Vac/125 Vdc*  
600 Vac  
Right front rotary, clockwise  
Left front rotary, clockwise  
Right side rotary, clockwise  
Left side rotary, counterclockwise  
200 kA AC  
100 kA DC  
600 Vac/125 Vdc*  
600 Vac  
600 Vac/125 Vdc*  
600 Vac  
600 Vac/125 Vdc*  
600 Vac  
1
2
3
2
3
2
3
2
3
2
3
347 Vac/125 Vdc**  
600 Vac/125 Vdc**  
600 Vac  
5
10  
20  
10  
20  
10  
20  
10  
20  
10  
20  
50  
50  
50  
50  
50  
40  
40  
40  
40  
40  
Switch only  
600 Vac/125 Vdc**  
600 Vac  
Right front rotary, clockwise  
Left front rotary, clockwise  
Right side rotary, clockwise  
Left side rotary, counterclockwise  
200 kA AC  
100 kA DC  
600 Vac/125 Vdc**  
600 Vac  
600 Vac/125 Vdc**  
600 Vac  
600 Vac/125 Vdc**  
600 Vac  
* 125 Vdc for installed fuse amp ratings up to 40 A. 24 Vdc for installed fuse amp ratings from 45 to 60 A.  
**125 Vdc for installed fuse amp ratings up to 80 A, 24 Vdc for installed fuse amp ratings from 90 to 100 A.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-5  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Box lug terminal conductor data  
Dimensions – mm (in)  
Switch (shown with optional terminal shrouds)  
Wire  
type  
AWG  
range Class  
Torque  
N•m (lb-in)  
Quantity  
30 and 60 A switches  
4-6  
3.95 (35)  
2.26 (20)  
3.39 (30)  
Stranded, Class B  
Single  
to K  
8-18  
Stranded, Class B/C  
Stranded, Class K  
114  
4.5  
6-8  
206  
8.1  
Dual  
2.26 (20)  
Stranded, Class B  
to K  
10-18  
75°C Cu  
76  
3.0  
10-18  
4-18  
6-18  
4-18  
6-18  
Solid  
Single/dual  
Single  
Twin†  
2.26 (20)  
3.39 (30)  
83  
3.3  
50  
2.0  
75  
3.0  
Stranded, UL ferrule,  
Class B/C  
Single  
Twin†  
25  
Stranded, UL ferrule,  
Class K  
2.82 (25)  
1.0  
30A Fuse  
100 A switches  
12-18  
10  
2.26 (20)  
2.82 (25)  
4.52 (40  
5.08 (45)  
6.21 (55)  
5.08 (45)  
2.26 (20)  
3.95 (35)  
4.52 (40)  
2.26 (20)  
2.82 (25)  
2.26 (20)  
2.26 (20)  
3.39 (30)  
5.08 (45)  
2.26 (20)  
3.39 (30)  
2.26 (20)  
75  
3.0  
89  
3.5  
8
Single  
Stranded, Class B/C  
4-6  
1-3  
4-12  
12-18  
10  
60A Fuse  
Dual  
30 and 60 amp switches  
Single  
Stranded, UL ferrule,  
Class B/C  
1-8  
75°C Cu  
10-18  
75  
3.0  
Twin†  
Single/Dual  
Single  
Dual  
6-9  
50  
2.0  
25  
10-18  
8-18  
1-7  
Solid  
148  
5.8  
1.0  
240  
Class K  
9.5  
3-10  
8-18  
1-7  
Single  
Class K, UL ferrule  
100  
3.9  
6-18  
Twin  
Two stranded conductors placed in one UL Listed twin ferrule.  
Lineside and loadside fork terminal  
•ꢀ  
Fork terminal suitable for line, load or accessory connection, max.  
30 A suitable for use with:  
100 amp switches  
•ꢀ 10-24 screw for 30 and 60 A switches  
•ꢀ 1/4-28 screw for 100 A switches  
Available Bussmann series fuses  
Data  
UL fuse  
class  
sheet  
no.  
Type/description  
Volts  
Indicating time-delay, Low-Peak™  
CUBEFuse (6-100 A)  
600 Vac/  
300 Vdc  
9000  
Non-indicating time-delay, Low-Peak  
CUBEFuse (1-100 A)  
CF  
Non-indicating fast-acting CUBEFuse  
(1-100 A)  
600 Vac/dc 2147  
11-6  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Right front rotary switches (shown with optional terminal shrouds)  
Left front rotary switches (shown with optional terminal shrouds)  
114  
114  
4.5  
4.5  
206  
8.1  
206  
8.1  
99  
3.9  
99  
3.9  
83  
3.3  
83  
3.3  
101  
4.0  
101  
4.0  
76  
3.0  
76  
3.0  
30 A Fuse  
30 A Fuse  
99  
3.9  
99  
3.9  
89  
3.5  
89  
3.5  
60 A Fuse  
60 A Fuse  
30 and 60 amp switches  
30 and 60 amp switches  
101  
4.0  
101  
4.0  
148  
5.8  
148  
76  
76  
3.0  
5.8  
3.0  
240  
9.5  
240  
9.5  
100 106  
3.9 4.2  
100 106  
3.9 4.2  
100 amp switches  
100 amp switches  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-7  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Left side rotary switches (shown with optional terminal shrouds)  
Right side rotary switches (shown with optional terminal shrouds)  
114  
4.5  
114  
4.5  
206  
206  
8.1  
8.1  
83  
3.3  
83  
3.3  
75  
3.0  
75  
3.0  
101  
4.0  
101  
4.0  
76  
3.0  
30 A Fuse  
30 A Fuse  
89  
3.5  
75  
3.0  
75  
3.0  
89  
3.5  
60 A Fuse  
60 A Fuse  
30 and 60 amp switches  
30 and 60 amp switches  
101  
4.0  
101  
4.0  
148  
5.8  
76  
3.0  
148  
5.8  
76  
3.0  
240  
9.5  
240  
9.5  
100  
3.9  
100  
3.9  
100 amp switches  
100 amp switches  
11-8  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
200 and 400 A switches  
Poles  
•ꢀ  
1-, 2- and 3-poles catalog number dependent  
Agency information  
•ꢀ  
UL 98 Listed, Guide WHTY, File E302370  
•ꢀ  
cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7,  
File E302370  
•ꢀ  
RoHS compliant  
Conductors/terminals  
•ꢀ  
See available lug table for size, type and torque information  
400 A switch  
200 A switch  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)*  
* For fuse performance under or above 25°C, consult fuse performance derating  
charts in the Bussmann Division publication no. 3002, titled Selecting Protective  
Devices (SPD)  
Lockout/tagout provisions using 1/4” lock  
•ꢀ  
Integral with switch handle  
•ꢀ  
Front rotary operating mechanism  
With side rotary accessory  
With front rotary accessory  
•ꢀ  
Rotary pistol handles  
•ꢀ  
Flange rod and cable operators  
Catalog no.  
Poles  
Amps  
Description  
Minimum enclosure size  
CCP2-1-200CF  
CCP2-2-200CF  
CCP2-3-200CF  
CCP2-1-400CF  
CCP2-2-400CF  
CCP2-3-400CF  
1
2
3
1
2
3
•ꢀ  
200 A switch 16 x 12 x 6” (405 x 305 x 150 mm)  
200  
•ꢀ  
400 A switch 24 x 16 x 8 (610 x 405 x 200 mm)  
Switch only  
Mounting  
•ꢀ  
Panel mount  
400  
Local open fuse indication minimum voltage  
Description  
•ꢀ  
90 Vac, requires an open fuse to be in the CCP2 and the switch in  
the ON position  
The Bussmann series 200 and 400 A Compact Circuit Protector  
(CCP2) fused disconnect switches utilize the finger-safe UL Class CF  
time-delay CUBEFuse with Class J electrical performance. With up  
to a 69 percent smaller footprint than a traditional fusible solution,  
these switches provide a high 200 kA SCCR to help improve panel  
and assembly SCCR.  
Accessories  
•ꢀ  
Lugs and lug kits with terminal shrouds  
•ꢀ  
Pistol handles for use with rotary operated switches  
•ꢀ  
NFPA 79 compliant handle  
The panel mount 200 and 400 A CCP2 switches are available with  
a variety of accessories to meet many application needs including  
rotary and flange handle operation.  
•ꢀ  
12 mm shafts for use with selector and pistol handles  
•ꢀ  
Auxiliary contacts  
•ꢀ  
Rotary operators are available for front or side (right or left)  
operation. Front rotary operators are for three-pole switches only  
while the side operator may be applied to the right or left side of 1-,  
2- and 3-pole units.  
Flange handle rod and cable operators  
Other accessories include lugs, terminal shrouds, rotary pistol  
handles, flange rod and cable operating mechanisms, NO/NC  
auxiliary contacts that easily integrate into various monitoring  
systems and a handle extension.  
Front and side rotary operated versions are easily applied for  
through-the-door or through the left or right side operation to  
enhance safety.  
Ratings  
•ꢀ  
Volts  
•ꢀ  
347 Vac (1-pole) 600 Vac (2- and 3-pole)  
•ꢀ  
Amps  
•ꢀ  
200 A  
•ꢀ  
400 A  
•ꢀ  
SCCR  
•ꢀ  
200 kA RMS Sym.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-9  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Features  
•ꢀ  
•ꢀ  
Standard local open fuse indication light on each pole speeds  
troubleshooting  
•ꢀ  
Uses UL Class CF time-delay CUBEFuse with Class J electrical  
performance  
Built-in switch interlock prevents inserting or removing fuse while  
in the ON position  
•ꢀ  
Amp rating rejection feature will not accept a CUBEFuse amp  
ratings greater than switch rating  
•ꢀ  
•ꢀ  
Padlockable for lockout/tagout procedures with a 1/4” lock  
•ꢀ  
High 200 kA short-circuit current rating  
Front and side rotary operator accessories provide for through-  
the-door and through-the-side operation flexibility and enhanced  
safety  
•ꢀ  
Disconnect rated to provide means for load isolation  
•ꢀ  
Full voltage rated at 600 Vac  
•ꢀ  
UL 98 Listed and suitable for branch circuit disconnect and branch  
circuit protection with installed fuses  
•ꢀ  
•ꢀ  
Optional pistol handles and shafts available for use with rotary  
operator accessories  
•ꢀ  
Horsepower rated (see table below)  
Multi-wire lug kits with terminal shrouds allow for power  
distribution to multiple loads.  
Catalog numbers and horsepower ratings  
Max Hp rating (Vac)  
Catalog no.  
Poles  
Description  
Volts AC  
SCCR  
240  
480  
600  
200 amp switches  
CCP2-1-200CF  
CCP2-2-200CF  
CCP2-3-200CF  
400 amp switches  
CCP2-1-400CF  
CCP2-2-400CF  
CCP2-3-400CF  
1
2
3
347  
600  
10  
50  
100  
150  
Switch only  
200 kA  
1
2
3
347  
600  
100  
200  
250  
Switch only  
200 kA  
Available lugs, conductor ratings and terminal torques  
Lugs per  
Wire range  
AWG (mm2)  
Wire type/ Conductor torque Lug mounting screw  
Catalog no.  
200 A switches  
CCP2-L2-1  
Description  
cat. no.  
temp.  
N•m (lb-in)  
torque N•m (lb-in)  
Stainless steel lug  
Aluminum lug*  
1
1
3
3
350-4 (185-25)  
350-4 (185-25)  
2-14 (35-2.5)  
6-14 (16-2.5)  
Cu 75°C  
20.3 (180)  
28.2 (250)  
7.9 (70)  
0.9 (8)  
13.5 (120)  
10.8 (95)  
10.8 (95)  
CCP2-L2-1A  
Cu/Al 75°C  
Cu/Al 75°C  
Cu/Al 75°C  
CCP2-MW2-3 3-port multi-wire terminal with shroud*  
CCP2-MW2-6 6-port multi-wire terminal with shroud*  
2.8 (25)  
* These lugs also accept 1/4” quick connect control wire terminals. Order catalog number CCP2-CWK2 (package of 12 terminals).  
400 A Switches  
CCP2-L4-1  
CCP2-L4-1A  
CCP2-L4B-3  
CCP2-L4B-3A Aluminum lug kit with shroud  
CCP2-L6-3  
Stainless steel lug  
Aluminum lug  
Stainless steel lug kit with shroud  
1
1
3
3
3
3
500-3 (240-35)  
500-3 (240-35)  
750-500 (400-240)  
750-500 (400-240) Cu/Al 75°C  
(2) 500-2 (240-35) Cu 75°C  
(2) 500-2 (240-25) Cu/Al 75°C  
Cu 75°C  
Cu/Al 75°C  
Cu 75°C  
42.0 (375)  
42.0 (375)  
57.0 (500)  
62.0 (550)  
42.0 (375)  
2-port stainless steel lug kit with shroud  
2-port aluminum lug kit with shroud  
22.0 (200)  
CCP2-L6-3A  
42.0 (375)  
10-14 = 3.9 (35)  
8 = 4.5 (40)  
4-6 = 5.0 (45  
1/0-2 = 5.6 (50)  
CCP2-MW6-6 6-port multi-wire terminal with shroud  
3
1/0-14 (50-2.5)  
Cu/Al 75°C  
Accessories  
Switch  
amps  
Catalog no.  
CCP2-TS2-3  
CCP2-PB2  
CCP2-RM2  
CCP2-TS6-3  
CCP2-PB6  
CCP2-RM4  
CCP2-SM  
Description  
3-pole terminal shroud  
Phase barriers (pack of 2)  
200  
Front rotary operator* (3-pole switch only)  
3-pole terminal shroud  
400  
Phase barriers (pack of 2)  
Front rotary operator* (3-pole switch only)  
200/400 Side rotary operator* (1-, 2- or 3-pole switches)  
* Complete installation requires pistol handle and shaft, order separately.  
11-10  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
200 amp switch dimensions — mm (in)  
Ø 5.0 (0.2) Thru  
Ø 9.2 (0.4) 5.4 (0.2)  
133.2 (5.2)  
104.7 (4.1)  
160.4 (6.3)  
119.7 (4.7)  
85.4 (3.4)  
34.9 (1.4) 34.9 (1.4)  
56.0  
(2.2)  
55.2  
(2.2)  
152.4  
(6.0)  
139.7  
(5.5)  
177.9  
(7.0)  
Front rotary  
mechanism  
accessory  
Side rotary  
mechanism  
accessory  
CCP2-SM  
CCP2-RM2  
34.9 (1.4) 34.9 (1.4)  
119.7  
(4.7)  
87.3  
(3.4)  
335.9  
(13.2)  
3-pole terminal  
shroud accessory  
CCP2-TS2-3  
104.8  
(4.1)  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-11  
Eaton.com/bussmannseries  
11 — Disconnect switches  
400 amp switch dimensions — mm (in)  
Ø 5.0 (0.2) Thru  
Ø 14.0 (0.5) 5.9 (0.2)  
159.3 (6.3)  
130.8 (5.1)  
175.8 (6.9)  
132.8 (5.2)  
102 (4.0)  
43.6 (1.7) 43.6 (1.7)  
56.0  
(2.2)  
98.8  
(3.9)  
225.0  
(8.8)  
214.4  
(8.4)  
257  
(10.1)  
Front rotary  
mechanism  
accessory  
Side rotary  
mechanism  
accessory  
CCP2-SM  
CCP2-RM4  
43.6 (1.7) 43.6 (1.7)  
132.9  
(5.2)  
101.4  
(4.0)  
365.0  
(14.3)  
3-pole terminal  
shroud accessory  
CCP2-TS6-3  
139.2  
(5.4)  
11-12  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Installed on CCP2-3-xx  
30, 60 and 100 A switch multi-wire lug kits  
Catalog numbers  
•ꢀ  
CCP2-MW1-3 (30 and 60 A switches only)  
•ꢀ  
CCP2-MW1-6 (100 A switches only)  
Description  
The multi-wire lug kits permit expanding each box lug terminal on  
the switch into a three-port (30 and 60 A switches) or six-port (100 A  
switches) terminal for power distribution applications.  
Each multi-wire lug kit comes with three lugs and three terminal  
shrouds. Shrouds provide finger-safe protection when properly  
installed.  
Lugs may be mounted on either the loadside or lineside to meet  
various application needs.  
Ports on any one lug accept any conductor combination listed, e.g.,  
one of the ports may have dual 14 AWG wires and the other two  
ports single 10 AWG wires.  
Multi-wire lugs mount in switch box lug terminals to provide three  
additional wire ports per pole. Lugs can be mounted on the switch  
lineside or loadside. Each multi-wire lug kit comes with three lugs  
and three shrouds.  
Ratings  
•ꢀ  
Volts 600 V  
•ꢀ  
Amps  
•ꢀ 60 A max (  
CCP2-MW1-3)  
Wire insulation strip lengths  
•ꢀ 100 A max (  
CCP2-MW1-6)  
1/8” Allen  
head screw  
1/8” Allen  
head screw  
•ꢀ  
SCCR 200 kA  
Agency information  
1 = 11/16”  
•ꢀ  
UL Recognized, Guide WHTY2, File E302370  
1 = 11/16”  
2 = 1-1/8”  
•ꢀ  
RoHS compliant  
2 = 1-1/8”  
3 = 1-9/16”  
Storage and operating temperature  
3 = 1-9/16”  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
Multi-wire lug conductor information  
Strip back wire insulation to the lengths as indicated in the  
illustration above and the table below.  
•ꢀ  
75°C Cu/AL  
•ꢀ  
AWG size and quantity per port - see table below  
Lug port  
Strip wire insulation back (inch)  
1
2
3
11/16  
1-1/8  
AWG  
Torque  
Type range Class  
Quantity  
N•m (lb-in)  
4-6  
8
3.95 (35)  
2.82 (25)  
2.26 (20)  
2.26 (20)  
2.82 (25)  
2.26 (20)  
1-9/16  
Cu/Al  
Stranded, Class B/C  
Single  
10-14 Stranded, Class B/C  
Single/dual*  
Single  
10-14 Solid  
8
Cu  
UL ferrule, Class B to K Single/twin†  
10-14  
* Dual wire to be same size and type.  
Two stranded conductors placed in one UL Listed twin ferrule.  
CCP2 box lug torque for multi-wire lugs  
•ꢀ  
30/60 A switch lug, 4.52 N•m (40 lb-in)  
•ꢀ  
100 A switch lug, 5.09 N•m (45 lb-in)  
Wiring versatility is provided by single/dual rated box lug terminals  
on the switch, or by the three-port or six-port multi-wire lug kits that  
are also single/dual wire rated.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-13  
Eaton.com/bussmannseries  
11 — Disconnect switches  
200 and 400 A switch multi-wire lug kits  
Installed on CCP2-3-xx  
Catalog numbers  
•ꢀ  
CCP2-MW2-3 ( 3-port, 200 A switches only)  
•ꢀ  
CCP2-MW2-6 (6-port, 200 A switches only)  
•ꢀ  
CCP2-MW6-6 (6-port, 400 A switches only)  
Description  
The multi-wire lug kits permit expanding the terminal on the switch  
into a three-port (200 A switches) or six-port (200 and 400 A  
switches) terminal for power distribution applications.  
Each multi-wire lug kit comes with three lugs and a 3-pole terminal  
shroud. The shroud provides finger-safe protection when properly  
installed.  
3- and 6-port multi-wire lugs mounted on 200 A switches  
Lugs can only be mounted on loadside to meet application needs.  
Ports on any one lug accept any conductor combination listed, e.g.,  
one of the ports may have dual 14 AWG wires and the other two  
ports single 10 AWG wires.  
Ratings  
•ꢀ  
Volts 600 V  
•ꢀ  
Amps  
•ꢀ 225 A max (  
•ꢀ 600 A max (  
SCCR 200 kA  
CCP2-MW2-3 and CCP2-MW2-6)  
CCP2-MW6-6)  
•ꢀ  
Agency information  
6-port multi-wire lugs mounted on 400 A switches  
•ꢀ  
UL Recognized, Guide WHTY2, File E302370  
•ꢀ  
RoHS compliant  
Multi-wire lugs mount on the switch terminals to provide three or  
six additional wire ports per pole. Lugs to be mounted only on the  
loadside. Each multi-wire lug kit comes with three lugs, a shroud and  
mounting hardware.  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
Multi-wire lug conductor information  
Wire insulation strip lengths  
•ꢀ  
75°C Cu/AL  
Straight blade  
head screw  
•ꢀ  
AWG size and quantity per port - see table below  
4 mm Allen  
head screw  
4 mm Allen  
head screw  
1 = 3/4 to 7/8”  
2 = 1-3/8 to 1-1/2”  
3 = 2 to 2-1/8”  
1 = 3/8 to 1/2”  
2 = 3/4 to 7/8”  
3 = 1-1/4 to 1-3/8”  
1 = 3/8 to 1/2”  
2 = 3/4 to 7/8”  
3 = 1-1/4 to 1-3/8”  
AWG  
Torque  
N•m (lb-in)  
Type range Class  
Quantity  
4-6  
3.95 (35)  
2.82 (25)  
2.26 (20)  
2.26 (20)  
2.82 (25)  
2.26 (20)  
CCP2-MW6-6  
CCP2-MW2-6  
CCP2-MW2-3  
Cu/Al  
Stranded, Class B/C  
Single  
8
Strip back wire insulation to the lengths indicated in the illustration  
above and the table below.  
10-14 Stranded, Class B/C  
Single/dual*  
Single  
10-14 Solid  
8
Cu  
Wire insulation strip length (inch)  
UL ferrule, Class B to K Single/twin†  
Lug kit  
Lug port 1  
3/8 to 1/2  
3/4 to 7/8  
Lug port 2  
Lug port 3  
1-1/4 to 1-3/8  
2 to 2-1/8  
10-14  
CCP2-MW2-3  
CCP2-MW2-6  
CCP2-MW6-6  
* Dual wire to be same size and type.  
Two stranded conductors placed in one UL Listed twin ferrule.  
3/4 to 7/8  
1-3/8 to 1-1/2  
11-14  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Pistol handles —short and long  
Selector and pistol handles  
Catalog symbol  
Selector handles  
•ꢀ  
CCP2-H4X-_1 (selector handle for 30, 60 and 100 A switches)  
•ꢀ  
CCP2-H4X-_2 (pistol handle for 30, 60 and 100 A switches)  
•ꢀ  
CCP2-H4X-_3 (short pistol handle for 200 and 400 A switches)  
•ꢀ  
CCP2-H4X-_4 (long pistol handle for 200 and 400 A switches)  
Description  
Selector and pistol handles are used with rotary operated switches.  
Pistol handles for 200 and 400 A switches come in short and long  
versions. All handles are available in black/gray and red/yellow  
colors, and clockwise/counterclockwise operating modes. Front and  
right side operated switches use clockwise handles while left side  
operated switches use counterclockwise handles.  
Agency information  
•ꢀ  
UL Listed, Guide DIHS/DIHS7, File E140305  
•ꢀ  
•ꢀ  
•ꢀ  
Type 1, 4X and 12  
RoHS compliant  
CE  
Installation requires an 8 mm shaft for 30, 60 and 100 A switches  
and a 12 mm shaft for 200 and 400 A switches (ordered separately).  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
Each handle is rated Type 1, 4X and 12, and accepts up to three (3)  
1/4” diameter shank locks for lockout/tagout in the OFF position.  
They can also be field configured for lock-on and are defeatable.  
Only the clockwise operating handles in combination with front  
rotary operating switches provide a door interlock means to ensure  
the enclosure door remains shut during lockout/tagout or lock-on.  
Rotary handles mounted on the enclosures left or right side do NOT  
provide a door interlock means.  
See the catalog number table below for applicable rotary switch,  
handle and shaft combinations.  
Handles and shafts for 30, 60 and 100 A switches  
For catalog no.  
Description/operation  
Order handle cat. no.  
Order either 8 mm shaft cat. no.  
CCP2R-(pole)-30CF  
CCP2R-(pole)-60CF  
CCP2R-(pole)-100CF  
CCP2RL-(pole)-30CF  
CCP2RL-(pole)-60CF  
CCP2RL-(pole)-100CF  
CCP2S-(pole)-30CF  
CCP2S-(pole)-60CF  
CCP2S-(pole)-100CF  
Right front rotary, clockwise  
CCP2-H4X-B1 (selector, black/grey)  
CCP2-H4X-R1(selector, red/yellow)  
CCP2-H4X-B2 (pistol, black/grey)  
CCP2-H4X-R2 (pistol, red/yellow)  
Left front rotary, clockwise  
Right side rotary, clockwise  
CCP2-SH1-290 (11.5”/290 mm)  
CCP2-SH1-490 (19.3”/490 mm)  
CCP2SL-(pole)-30CF  
CCP2SL-(pole)-60CF  
CCP2SL-(pole)-100CF  
CCP2-H4X-B1L (selector, black/grey)  
CCP2-H4X-R1L (selector, red/yellow)  
CCP2-H4X-B2L (pistol, black/grey)  
CCP2-H4X-R2L (pistol, red/yellow)  
Left side rotary,  
counterclockwise  
Handles and shafts for 200 and 400 A switches  
Order front  
rotary  
mechanism  
cat. no.  
Order right/  
left side rotary  
mechanism  
cat. no.  
Order left side counterclockwise  
Order either 12  
Order front/right side clockwise handles (use only with CCP2-SM) mm shaft cat.  
For catalog no.  
handle cat. no.  
cat. no.  
no.  
CCP2-H4X-B3 (short - black/grey) CCP2-H4X-B3L (short - black/grey)  
CCP2-H4X-R3 (short - red/yellow) CCP2-H4X-R3L (short - red/yellow)  
CCP2-(poles)-200CF  
CCP2-RM2*  
CCP2-RM4*  
CCP2-SH2-225  
(8.9”/225 mm)  
CCP2-SM  
CCP2-H4X-B4 (long - black/grey)  
CCP2-H4X-R4 (long - red/yellow)  
CCP2-H4X-B4L (long - black/grey)  
CCP2-H4X-R4L (long - red/yellow)  
CCP2-SH2-425  
(16.7”/425 mm)  
CCP2-(poles)-400CF  
* For three-pole switches only.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-15  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Handle dimensions — mm (in)  
Handle shafts  
Selector for 8 mm shafts  
8 mm shafts  
28  
(1.1)  
Ø7  
(0.3)  
85  
(3.3)  
71  
(2.8)  
Short pistol for 8 mm and 12 mm shafts  
12 mm shafts  
33  
(1.3)  
85  
(3.3)  
Ø7  
(0.3)  
ON  
OFF  
129  
(5.1)  
71  
(2.8)  
Catalog numbers  
•ꢀ  
CCP2-SH1-290 (8 mm, 290 mm long)  
Long pistol for 12 mm shafts  
•ꢀ  
CCP2-SH1-490 (8 mm, 490 mm long)  
85  
34  
(3.3)  
(1.3)  
•ꢀ  
CCP2-SH2-225 (12 mm, 225 mm long)  
Ø7  
(0.3)  
•ꢀ  
CCP2-SH2-425 (12 mm, 425 mm long)  
68  
96  
(3.8)  
(2.7)  
Description  
85  
(3.3)  
71  
(2.8)  
Square shafts available in:  
28  
(1.1)  
179  
(7.0)  
•ꢀ  
8 mm square by 290 and 490 mm lengths for 30, 60 and 100 A  
switches  
71  
(2.8)  
•ꢀ  
12 mm square by 225 and 425 mm lengths for 200 and 400 A  
switches  
All shafts are indexed to ensure handle/switch orientation for correct  
operation. Shafts are to be cut to length when installed.  
NFPA 79 compliant handles  
Catalog numbers  
•ꢀ  
CCP2-NFPA-1  
(8 mm shafts for 30-100 A switches)  
•ꢀ  
CCP2-NFPA-2  
(12 mm shafts for 200 and 400 A switches)  
Description  
NFPA 79 handles mount on the shaft of  
front rotary operated switch installations and  
provide a lockout means independent of the  
door position.  
11-16  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Flange handle rod and cable operators  
Catalog no.  
Description  
Rating  
30, 60 and 100 amp switches  
CCP2-FLR1  
Rod operator with painted handle  
Type 1, 3R, 12  
Type 4X  
CCP2-FLR1X  
Rod operator with chrome handle  
36” Cable with painted handle  
36” Cable with chrome handle  
60” Cable with painted handle  
60” Cable with chrome handle  
120” Cable with painted handle  
CCP2-FLC1-36  
CCP2-FLC1-36X  
CCP2-FLC1-60  
CCP2-FLC1-60X  
CCP2-FLC1-120  
Type 1, 3R, 12  
Type 4X  
Type 1, 3R, 12  
Type 4X  
Type 1, 3R, 12  
Type 4X  
Flange rod operator kit for 30, 60 and 100 A switches.  
CCP2-FLC1-120X 120” Cable with chrome handle  
200 and 400 amp switches  
CCP2-FLR2  
Rod operator with painted handle  
Rod operator with chrome handle  
36” Cable with painted handle  
36” Cable with chrome handle  
60” Cable with painted handle  
60” Cable with chrome handle  
120” Cable with painted handle  
Type 1, 3R, 12  
Type 4X  
CCP2-FLR2X  
CCP2-FLC2-36  
CCP2-FLC2-36X  
CCP2-FLC2-60  
CCP2-FLC2-60X  
CCP2-FLC2-120  
Type 1, 3R, 12  
Type 4X  
1, 3R, 12  
Type 4X  
Type 1, 3R, 12  
Type 4X  
CCP2-FLC2-120X 120” Cable with chrome handle  
Description  
Flange rod operator kit for 200 and 400 A switches.  
Flange rod and cable operators for use on 2- and 3-pole CCP2  
switches (cannot be used with 2- or 3-pole 30, 60 or 100 amp  
switches already having a front or side rotary operating mechanism).  
Handles are available in painted versions with NEMA 1, 3R and 12  
ratings or chrome versions with a NEMA 4X rating.  
Cable operators are available with 36, 60 and 120 inch cable  
lengths.  
Agency information  
•ꢀ  
Type 1, 4X and 12  
•ꢀ  
RoHS compliant  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
Packaging  
Flange cable operator kit for 30, 60 and 100 A switches.  
•ꢀ  
Each handle is packaged individually as a kit  
Flange cable operator kit for 200 and 400 A switches.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-17  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Front rotary mechanisms for 200 and 400 A switches  
Phase barriers  
Catalog numbers  
•ꢀ  
CCP2-PB2  
(3-pole 200 A switches)  
•ꢀ  
CCP2-PB6  
(3-pole 400 A switches)  
Description  
Phase barrier kit with two phase  
barriers for isolation between the  
lugs on 3-pole 200 and 400 A  
switches.  
Catalog numbers  
Packaged individually.  
•ꢀ  
CCP2-RM2 (3-pole 200 A switches)  
•ꢀ  
CCP2-RM4 (3-pole 400 A switches)  
Handle extension  
Description  
Front rotary mechanisms for through-the-door operation and install  
on the front of 3-pole switches only. These units provide at-switch  
lockout/tagout capability for enhanced safety. Complete installation  
requires installing pistol handle (short or long) and 12 mm shaft.  
Packaged individually.  
Side rotary mechanism for 200 and 400 A switches  
Catalog number  
•ꢀ  
CCP2-HEX (1-, 2- and 3-pole 200 and 400 A  
switches)  
Description  
A handle extension to provide additional leverage for operating the  
switch in installations that do not have rotary mechanisms or flange  
operators installed. Does not mount on switch, provision for tether  
provided.  
Packaged individually.  
Catalog number  
•ꢀ  
CCP2-SM  
(1-, 2- or 3-pole 200 and 400 A switches)  
Description  
Side rotary mechanism for through-the-side operation and installs  
on the left or right side (right side installation recommended) of any  
1-, 2- or 3-pole 200 and 400 A switch. The side rotary mechanism  
does not provide for door interlock nor local lockout/tagout capability.  
Complete installation requires installing pistol handle (short or long)  
and 12 mm shaft.  
Packaged individually.  
Terminal shrouds  
Catalog numbers  
•ꢀ  
CCP2-TS2-3  
(3-pole 200 A switches)  
•ꢀ  
CCP2-TS6-3  
(3-pole 400 A switches)  
Description  
3-pole shroud kit with  
shields for isolating the  
lugs on 3-pole 200 and  
400 A switches.  
Packaged individually.  
11-18  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Installed on a CCP2-3-xx  
Auxiliary contacts for 30, 60 and 100 A switches  
Note: CCP2-AUX and CCP2-AUX-100 CANNOT be mounted on the  
right front and right side rotary operated versions, nor installed with  
the flange handle rod or cable operator.  
Catalog numbers  
•ꢀ  
CCP2-AUX (30 and 60 A switches)  
•ꢀ  
CCP2-AUX-100 (100 A switches)  
Description  
NO+NC contact output to indicate the  
switching mechanism status on the  
CCP2. A single unit can be mounted  
on any 1-, 2- or 3-pole CUBEFuse  
CCP2 switch and the left front/left side  
rotary operated switches.  
Ratings  
•ꢀ  
240 Vac max  
•ꢀ  
5 A max  
•ꢀ  
NC/NO contacts are closed/open when the CCP2 switch is in the  
“ON” position (closed)  
Catalog no.  
Switch Description  
Max per CCP2*  
Ratings  
30/60 A  
only  
CCP2-AUX  
Auxiliary contacts  
N/NC for switch  
status  
1 per CCP2  
(1-, 2- or 3-pole)  
5 A / 240 Vac  
100 A  
only  
Dimensions — in  
CCP2-AUX-100  
1.8  
* The CCP2-AUX CANNOT be mounted on the right front and right side rotary  
operated versions, nor installed with the flange handle rod or cable operator.  
De-energize all circuits and follow all prescribed safety procedures before  
installing or removing the auxiliary contact device.  
Agency information  
•ꢀ  
UL 98 Recognized, Guide WHTY2, File E155130  
2.6  
STRIP  
•ꢀ  
cURus to Canadian Standard 22.2 No. 4-04  
1.9  
33 NO  
41 NC  
34 NO  
42 NC  
•ꢀ  
Finger-safe in installed state  
•ꢀ  
RoHS compliant  
•ꢀ  
CE  
Wiring  
.190  
3.7  
16-20 AWG (1.5 to 0.5 mm2) single and dual stranded wire  
•ꢀ  
0.3  
20 AWG (1.5 mm2) single and dual solid wire  
CCP2-AUX  
•ꢀ  
•ꢀ  
Torque 0.56 N•m (5 lb-in)  
•ꢀ  
Use only 75°C Cu wire  
1.8  
Packaging  
•ꢀ  
CCP2-AUX and CCP2-AUX-100 are packaged individually  
Installation technique  
•ꢀ  
Mounts on the CCP2s right side ONLY and mechanically  
interlocks with the CCP2 switch handle with provided hardware.  
The CCP2-AUX and CCP2-AUX-100 CANNOT be mounted on the  
right front and right side rotary operated versions, nor installed  
with the flange handle rod or cable operator.  
2.9  
33 NO  
34 NO  
42 NC  
STRIP  
2.2  
Storage and operating temperature  
41 NC  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
.190  
3.7  
0.3  
CCP2-AUX-100  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-19  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Auxiliary contacts for 200 and 400 A switches  
Installed on a CCP2-3-xx  
Note: CCP2-AUX-S CANNOT be mounted on the same side as the  
side rotary mechanism CCP2-SM or the right side if a flange handle  
rod or cable operator is installed.  
Catalog number  
•ꢀ  
CCP2-AUX-S (200 and 400 A switches)  
Description  
NO+NC contact output to indicate the  
switching mechanism status on the  
CCP2. A single unit can be mounted  
on either side of any 1-, 2- or 3-pole  
switch (cannot be mounted on the  
same side as the CCP2-SM side  
rotary mechanism or the right side if a  
flange handle rod or cable operator is  
installed).  
Ratings  
•ꢀ  
240 Vac max  
•ꢀ  
5 A max  
•ꢀ  
NC/NO contacts are closed/open when the CCP2 switch is in the  
“ON” position (closed)  
Catalog no. Switch  
Description  
Max per CCP2*  
Ratings  
Auxiliary contacts  
NO+NC for switch  
status  
200 and  
CCP2-AUX-S  
1 per CCP2  
(1-, 2- or 3-pole)  
5 A / 240 Vac  
400 A  
* The CCP2-AUX-S CANNOT be mounted on the same side where the side rotary  
mechanism (CCP2-SM) is installed.  
De-energize all circuits and follow all prescribed safety procedures before  
installing or removing the auxiliary contact device.  
Agency information  
•ꢀ  
UL 98 Recognized, Guide WHTY2, File E155130  
•ꢀ  
cURus to Canadian Standard 22.2 No. 4-04  
•ꢀ  
Finger-safe in installed state  
•ꢀ  
RoHS compliant  
Wiring  
16-20 AWG (1.5 to 0.5 mm2) single and dual stranded wire  
•ꢀ  
20 AWG (1.5 mm2) single and dual solid wire  
•ꢀ  
•ꢀ  
Torque 0.56 N•m (5 lb-in)  
•ꢀ  
Use only 75°C Cu wire  
Installation technique  
•ꢀ  
Mounts on either side of the 200 and 400 A switches and  
mechanically interlocks with the switch’s handle with provided  
hardware. The CCP2-AUX-S CANNOT be mounted on the same  
side with an installed CCP2-SM side rotary mechanism, or the  
flange cable/rod operating mechanisms.  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
Packaging  
•ꢀ  
Packaged individually.  
11-20  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Agency information  
PLC fuse monitor for 30, 60 and 100 A switches  
•ꢀ  
UL 98 Recognized, Guide WHTY2, File E155130  
cURus to Canadian Standard 22.2 No. 4-04  
Catalog numbers  
•ꢀ  
•ꢀ  
CCP2-PLC-IND  
(30/60 A switches)  
Local indication  
•ꢀ  
CCP2-PLC-100  
(100 A switches)  
•ꢀ  
Two distinct LEDs indicate unit power (green) and open fuse  
(red). Open fuse LED is resettable upon fuse replacement and the  
actuating the reset switch  
Description  
A resettable three-phase  
Wiring  
fuse monitor that integrates  
•ꢀ  
For power, signal and ground connections use shielded twisted  
with the I/O card in a  
pair 22-24 AWG (0.34-0.25 mm2) 300 V rated wire  
Programmable Logic  
Controller (PLC). A single  
unit can be mounted on any  
Installation technique  
1-, 2- or 3-pole CUBEFuse  
•ꢀ  
Mounts on the left side ONLY of the CCP2 and mechanically  
CCP2 switch up to 100 A  
interlocks with the CCP2 switch handle with hardware provided.  
The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on  
the left front/left side rotary operated versions or if a multi-wire  
lug kit is installed or if the flange handle rod operator is installed.  
and the left front/ left side  
rotary operated switches.  
A single unit monitors up to three phases. When used on 1- and  
2-pole switches unused conductor(s) are removed after installation.  
The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on  
the left front/left side rotary operated versions or if a multi-wire lug  
kit is installed or if a multi-wire lug kit is installed, or if the flange  
handle rod operator is installed.  
IP20 rating — yes  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
Ratings  
PLC programming  
•ꢀ  
Signal output to PLC*  
•ꢀ  
The CCP2-PLC-IND or CCP2-PLC-100 signal line is designed  
•ꢀ +24 Vdc, 10 mA max  
to provide a digital input to a PLC I/O card. In this case, a  
Programmable Logic Control program must be written to properly  
interpret the input signal to the PLC. The PLC program should  
check for consecutive high signals before taking action on a  
critical process.  
•ꢀ  
Output signals  
•ꢀ Digital 0 Vdc (low), 24 Vdc max (high)  
•ꢀ 0 Vdc Low – fuse is good  
•ꢀ 24 Vdc High – fuse has opened  
* When the fuse opens, the output signal is sent high and will remain high until  
the unit is reset.  
Emissions and immunity testing  
•ꢀ  
IEC 60947-1: Voltage Switchgear and Control Gear  
•ꢀ  
IEC 61000-6-2: Electromagnetic Compatibility (EMC)  
•ꢀ IEC 61000-4-2: Electrostatic Discharge Immunity - Test at level  
3 (6 kV-Contact Discharge) and level 2 (4 kV-Air Discharge)  
•ꢀ IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radio-  
frequency, Electromagnetic Field Immunity test at level x (20  
V/m)  
•ꢀ IEC 61000-4-4: Electromagnetic Compatibility - Testing and  
Measurement Techniques at level 3 (± 2kV - Power Port and  
±1 kV - I/O Ports)  
•ꢀ IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity  
test at level 4 (±4 kV)  
•ꢀ IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V)  
Signal  
Min.  
Max per  
CCP2**  
output circuit  
Catalog no.  
Switch Description  
to PLC  
volts  
Wired  
30/60 A  
CCP2-PLC-IND  
remote fuse 1 per CCP2  
only  
24 Vdc/  
10 mA  
indication  
for PLC  
applications  
(1, 2- or  
3-pole)  
100 Vac  
100 A  
only  
CCP2-PLC-100  
**The CCP2-PLC-IND and CCP2-PLC-100 CANNOT be mounted on the left front/  
left side rotary operated versions or if a multi-wire lug kit is installed.  
De-energize all circuits and follow all prescribed safety procedures before installing  
or removing the CCP2-PLC-IND or CCP2-PLC-100.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-21  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Installed on a CCP2-3-xx  
PLC wiring schematic  
PLC power supply  
PLC fuse monitor  
+24 Vdc  
+24 Vdc  
0 Vdc/Gnd  
0 Vdc/Gnd  
Signal  
10 mA max.  
The PLC fuse monitor needs  
to be powered by the same  
+24 Vdc and ground  
(0 Vdc/Gnd return)  
terminals that feed the  
PLC input card.  
If it is not, it may  
improperly signal.  
If feeding multiple  
+24 Vdc  
PLC fuse monitors from  
different power supplies,  
there must be multiple  
input cards being powered  
by those same power  
supplies as well.  
0 Vdc/Gnd  
PLC  
CCP2-PLC-IND mounted on a 3-pole switch and using the fork  
terminals. When mounted on a 2- or 1-pole switch, remove unused  
leads.  
input card  
Note: the CCP2-PLC-IND CANNOT be mounted on the left front/left  
side rotary operated versions or if the multi-wire lug kit is installed or  
if the flange handle rod operator is installed.  
Dimensions — in  
1.8  
Pin interlocks with  
CCP2 switch handle  
2.6  
1.9  
3.7  
0.3  
30 and 60 A CCP  
2.0  
Pin interlocks with  
CCP2 switch handle  
2.9  
2.2  
0.3  
3.7  
100 A CCP  
11-22  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Ordering a complete switch installation  
30 and 60 A CCP2 switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Switch (used alone or with flange cable or flange rod handles)  
CCP2-1-30CF  
1
2
3
1
2
3
CCP2-2-30CF  
CCP2-3-30CF  
CCP2-1-60CF  
CCP2-2-60CF  
CCP2-3-60CF  
30  
60  
And  
Flange handle rod  
operator  
Description — 3-pole switches only  
Rating  
1, 3R and 12  
4X  
CCP2-FLR1-21  
CCP2-FLR1-21X  
Red/black painted handle  
Chrome handle  
Or  
Flange handle cable  
operator  
Description - 3-pole switches only, cannot be used with side or  
front rotary mechanisms  
Rating  
Type 1, 3R, 12  
Type 4X  
CCP2-FLC1-36  
CCP2-FLC1-36X  
CCP2-FLC1-60  
CCP2-FLC1-60X  
CCP2-FLC1-120  
CCP2-FLC1-120X  
36” cable, red/black painted handle  
36” cable, chrome handle  
60” cable, red/black painted handle  
60” cable, chrome handle  
Type 1, 3R, 12  
Type 4X  
120” cable, red/black painted handle  
120” cable, chrome handle  
Type 1, 3R, 12  
Type 4X  
Multi-wire lug kits  
Description  
CCP2-MW1-3  
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
And  
Terminal shrouds  
Description  
CCP2-TS1-3  
Pack of 3  
Description — mounts on right side, cannot be used with flange handle rod or  
cable operator  
Auxiliary contacts  
CCP2-AUX  
NO/NC, 5 A / 240 V  
Description — mounts on left side, cannot be used with flange handle rod  
operator  
PLC fuse monitor  
CCP2-PLC-IND  
Signal output 24 Vdc / 10 mA  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-23  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Ordering a complete switch installation  
30 and 60 A CCP2 clockwise rotary switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Right front rotary  
CCP2R-2-30CF  
2
3
2
3
30  
60  
CCP2R-3-30CF  
CCP2R-2-60CF  
CCP2R-3-60CF  
Left front rotary  
CCP2RL-2-30CF  
CCP2RL-3-30CF  
CCP2RL-2-60CF  
CCP2RL-3-60CF  
Right side rotary  
CCP2S-2-30CF  
CCP2S-3-30CF  
CCP2S-2-60CF  
CCP2S-3-60CF  
2
3
2
3
30  
60  
2
3
2
3
30  
60  
And  
Rotary handles  
Description  
Rating  
CCP2-H4X-B1  
Selector handle — black/grey  
Selector handle — red/yellow  
Pistol handle — black/grey  
Pistol handle — red/yellow  
CCP2-H4X-R1  
CCP2-H4X-B2  
CCP2-H4X-R2  
Type 1, 4X, 12  
And  
Shafts (8 mm)  
CCP2-SH1-290  
CCP2-SH1-490  
Length  
290 mm  
490 mm  
NFPA 79 compliant  
handle  
Color  
CCP2-NFPA-1  
Red  
And  
Multi-wire lug kits  
Description  
CCP2-MW1-3  
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
11-24  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
And  
Terminal shrouds  
Description  
CCP2-TS1-3  
Pack of 3  
Auxiliary contacts  
Description — use with CCP2RL-(poles)-30/60CF switches  
CCP2-AUX  
NO/NC, 5 A / 240 V  
Description — use with CCP2R-(poles)-30/60CF and CCP2S-(poles)-30/60CF  
switches  
PLC fuse monitor  
CCP2-PLC-IND  
Signal output 24 Vdc / 10 mA  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-25  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Ordering a complete switch installation  
30 and 60 A CCP2 counterclockwise switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Left side rotary  
CCP2SL-2-30CF  
CCP2SL-3-30CF  
CCP2SL-2-60CF  
CCP2SL-3-60CF  
2
3
2
3
30  
60  
And  
Rotary handles  
Description  
Rating  
CCP2-H4X-B1L  
Selector handle — black/grey  
Selector handle — red/yellow  
Pistol handle — black/grey  
Pistol handle — red/yellow  
CCP2-H4X-R1L  
CCP2-H4X-B2L  
CCP2-H4X-R2L  
Type 1, 4X, 12  
And  
Shafts (8 mm)  
CCP2-SH1-290  
CCP2-SH1-490  
Length  
290 mm  
490 mm  
NFPA 79 compliant  
handle  
Color  
CCP2-NFPA-1  
Red  
And  
Multi-wire lug kits  
Description  
CCP2-MW1-3  
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
And  
Terminal shrouds  
CCP2-TS1-3  
Description  
Pack of 3  
Auxiliary contacts  
Description —mounts on right side  
CCP2-AUX  
NO/NC, 5 A / 240 V  
11-26  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Ordering a complete switch installation  
100 A CCP2 switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Switch (used alone or with flange cable or flange rod handles)  
CCP2-1-100CF  
1
2
3
CCP2-2-100CF  
CCP2-3-100CF  
100  
And  
Flange handle rod  
operator  
Description — 3-pole switches only  
Rating  
1, 3R and 12  
4X  
CCP2-FLR1-21  
CCP2-FLR1-21X  
Red/black painted handle  
Chrome handle  
Or  
Flange handle cable  
operator  
Description - 3-pole switches only, cannot be used with side or  
front rotary mechanisms  
Rating  
Type 1, 3R, 12  
Type 4X  
CCP2-FLC1-36  
CCP2-FLC1-36X  
CCP2-FLC1-60  
CCP2-FLC1-60X  
CCP2-FLC1-120  
CCP2-FLC1-120X  
36” cable, red/black painted handle  
36” cable, chrome handle  
60” cable, red/black painted handle  
60” cable, chrome handle  
Type 1, 3R, 12  
Type 4X  
120” cable, red/black painted handle  
120” cable, chrome handle  
Type 1, 3R, 12  
Type 4X  
Multi-wire lug kits  
Description  
CCP2-MW1-6  
6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
And  
Terminal shrouds  
Description  
CCP2-TS1-6  
Pack of 3  
Description — mounts on right side, cannot be used with flange handle rod or  
cable operator  
Auxiliary contacts  
CCP2-AUX-100  
NO/NC, 5 A / 240 V  
Description — mounts on left side, cannot be used with flange handle rod  
operator  
PLC fuse monitor  
CCP2-PLC-100  
Signal output 24 Vdc / 10 mA  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-27  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Ordering a complete switch installation  
100 A CCP2 clockwise rotary switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Right front rotary  
CCP2R-2-100CF  
CCP2R-3-100CF  
2
3
100  
Left front rotary  
CCP2RL-2-100CF  
2
3
100  
100  
CCP2RL-3-100CF  
Right side rotary  
CCP2S-2-100CF  
2
3
CCP2S-3-100CF  
And  
Rotary handles  
Description  
Rating  
CCP2-H4X-B1  
Selector handle — black/grey  
Selector handle — red/yellow  
Pistol handle — black/grey  
Pistol handle — red/yellow  
CCP2-H4X-R1  
CCP2-H4X-B2  
CCP2-H4X-R2  
Type 1, 4X, 12  
And  
Shafts (8 mm)  
CCP2-SH1-290  
CCP2-SH1-490  
Length  
290 mm  
490 mm  
NFPA 79 compliant  
handle  
Color  
CCP2-NFPA-1  
Red  
And  
Multi-wire lug kits  
Description  
CCP2-MW1-6  
6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
11-28  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
And  
Terminal shrouds  
Description  
CCP2-TS1-6  
Pack of 3  
Auxiliary contacts  
Description — cannot be used on right front or right side operated switches  
CCP2-AUX-100  
NO/NC, 5 A / 240 V  
PLC fuse monitor  
Description — Cannot be used on left front or left side operated switches  
CCP2-PLC-100  
Signal output 24 Vdc / 10 mA  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-29  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Ordering a complete switch installation  
100 A CCP2 counterclockwise switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Left side rotary  
CCP2SL-2-100CF  
CCP2SL-3-100CF  
2
3
100  
And  
Rotary handles  
Description  
Rating  
CCP2-H4X-B1L  
Selector handle — black/grey  
Selector handle — red/yellow  
Pistol handle — black/grey  
Pistol handle — red/yellow  
CCP2-H4X-R1L  
CCP2-H4X-B2L  
CCP2-H4X-R2L  
Type 1, 4X, 12  
And  
Shafts (8 mm)  
CCP2-SH1-290  
CCP2-SH1-490  
Length  
290 mm  
490 mm  
NFPA 79 compliant  
handle  
Color  
CCP2-NFPA-1  
Red  
And  
Multi-wire lug kits  
Description  
CCP2-MW1-6  
6-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
And  
Terminal shrouds  
CCP2-TS1-6  
Description  
Pack of 3  
Auxiliary contacts  
CCP2-AUX-100  
Description — mounts on right side  
NO/NC, 5 A / 240 V  
11-30  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Features  
About the UL Class CF CUBEFuse  
•ꢀ  
Smallest installed footprint of any UL Class CC, J, or R fuse  
solution  
•ꢀ  
Easy application using CUBEFuse holders (TCFH_N), UL 98  
Compact Circuit Protector (CCP2) switches and Compact  
Circuit Protector Base (CCP2B up to 100 A). See data sheet  
9007 for details on the CUBEFuse holder, 10801 for details on  
the CCP2-_CF switch and 1161 for the CCP2B.  
•ꢀ  
Holders and switches have an amp rating rejection feature  
to help prevent overfusing; 30, 60 and 100 A switches and  
holders will hold any CUBEFuse up to its rating, 200 and 400  
A switches and 200, 225 and 400 A holders will hold any  
CUBEFuse 110 A and above up to its rating  
•ꢀ  
•ꢀ  
•ꢀ  
UL Class CF with Class J time-delay electrical performance  
Available in indicating and non-indicating versions  
The Bussmann series Low-Peak CUBEFuse is a UL Class CF current-  
limiting, dual-element, time-delay branch circuit fuse with Class J  
electrical performance. Available in indicating and non-indicating  
versions, this finger-safe fuse has a very compact, space-saving  
size and is easily applied using the CUBEFuse holder (TCFH_N),  
UL 98 Compact Circuit Protector switch (CCP2-_CF) or Compact  
Circuit Protector Base (CCP2B up to 100 A) used in the Quik-Spec  
Coordination Panelboard).  
The indicating version features local easyID™ open fuse  
technology for faster troubleshooting and reduced downtime  
•ꢀ  
•ꢀ  
•ꢀ  
•ꢀ  
Faster response to damaging faults helps reduce destructive  
thermal and magnetic forces  
True dual-element fuse construction with a minimum 10  
seconds time-delay at 500% of rating  
Ratings  
Long time-delay minimizes nuisance openings caused by  
temporary overloads and transient surges  
•ꢀ  
Volts  
•ꢀ 600 Vac  
•ꢀ 300 Vdc  
Up to 300 kA interrupting rating safely interrupts virtually any  
fault  
•ꢀ  
•ꢀ  
•ꢀ  
Robust cycling and inrush current withstand  
Low let-through currents under fault conditions  
•ꢀ  
Amps  
•ꢀ 6-400 A (indicating)  
Provides Type 2 “No Damage” protection for IEC motor starters  
when properly sized  
•ꢀ 1-400 A (non-indicating)  
•ꢀ  
Interrupting rating  
•ꢀ  
Easy selective coordination with any other Bussmann series  
Low-Peak Class CC, J, L or RK1 fuse with simple 2:1 amp ratio  
between upstream and downstream fuses  
•ꢀ 300 kA RMS Sym. (Up to 100 A UL)  
•ꢀ 200 kA RMS Sym. (110 to 400 A UL)  
•ꢀ 200 kA RMS Sym. (Up to 100 A CSA)  
•ꢀ 100 kA DC (Up to 400 A UL and up to 100 A CSA)  
* Finger-safe status depends on final, installed application, and will require  
using accessory shrouds for 110 to 400 A ratings.  
CUBEFuse (cat. no. TCFH_N) holders  
Agency information  
The CUBEFuse is also used in holders that can be dovetail  
together for the smallest footprint possible of any Class J fuse  
solution (see data sheet no. 9007 for details).  
•ꢀ  
UL Listed Class CF fuse: Guide JDDZ, File E4273 (up to 400 A)  
CSA® Certified fuse: Class 1422-02,  
File 053787_C_000 (up to 100 A)  
•ꢀ  
Finger-safe DIN-Rail or  
panel mount holders up to  
100 A.  
•ꢀ  
CE  
•ꢀ  
RoHS compliant  
•ꢀ  
30 A holder accepts any  
CUBEFuse up to 30 A.  
Catalog numbers (amps)  
Indicating CUBEFuse  
•ꢀ  
60 amp holder accepts any  
CUBEFuse up to 60 A.  
TCF6  
TCF30  
TCF35  
TCF40  
TCF45  
TCF50  
TCF60  
TCF70  
TCF80  
TCF90  
TCF100  
TCF110  
TCF125  
TCF150  
TCF175  
TCF200  
TCF225  
TCF250  
TCF300  
TCF350  
TCF400  
•ꢀ  
100 amp holder accepts any  
CUBEFuse up to 100 A.  
TCF10  
TCF15  
TCF17-1/2  
TCF20  
TCF25  
Panel mount holders from  
200 to 400 A.  
•ꢀ  
200 A holder accepts any  
CUBEFuse from 110 to 200 A  
Non-Indicating CUBEFuse  
•ꢀ  
225 A* holder accepts any  
CUBEFuse from 110 to 225 A  
TCF1RN  
TCF3RN  
TCF6RN  
TCF10RN  
TCF15RN  
TCF20RN  
TCF25RN  
TCF30RN  
TCF35RN  
TCF40RN  
TCF50RN  
TCF60RN  
TCF70RN  
TCF80RN  
TCF90RN  
TCF100RN  
TCF110RN  
TCF125RN  
TCF150RN  
TCF175RN  
TCF200RN  
TCF225RN  
TCF250RN  
TCF300RN  
TCF350RN  
TCF400RN  
•ꢀ  
400 A holder accepts any  
CUBEFuse from 110 to 400 A  
Finger-safe installation  
achievable for three ganged  
holders and lug kits with  
shroud  
TCF17-1/2RN TCF45RN  
* 200 A and 225 A holders share the same overall dimensions, but the 200 A  
holder will reject a 225 A fuse.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-31  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Ordering a complete switch installation  
200 A CCP2 switches  
For a complete installation, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
CCP2-1-200CF  
1
CCP2-2-200CF  
CCP2-3-200CF  
200  
2
3
And  
Lug kits  
Description  
CCP2-L2-1  
Stainless steel lug, 75° Cu only, 350 kcmil-4, 1 per pack  
Aluminum lug, 75°C Cu/Al, 350 kcmil-4, 1 per pack  
CCP2-L2-1A  
CCP2-MW2-3  
CCP2-MW2-6  
3-port multi-wire lug, 75°C Cu/Al, 2-14, 3 per pack, includes terminal shroud  
6-port multi-wire lug, 75°C Cu/Al, 6-14, 3 per pack, includes terminal shroud  
And  
Rotary  
mechanisms  
Description  
CCP2-SM  
Side rotary mechanism - mounts on left or right side of 1-, 2- and 3-pole switches  
Front rotary mechanism - mounts only on 3-pole switches, requires clockwise  
rotating handle  
CCP2-RM2  
And  
Rotation - must match  
Rotary handles  
CCP2-H4X-B3  
CCP2-H4X-R3  
CCP2-H4X-B4  
CCP2-H4X-R4  
CCP2-H4X-B3L  
CCP2-H4X-R3L  
CCP2-H4X-B4L  
CCP2-H4X-R4L  
Description  
switch rotation  
Rating  
Short pistol handle — black/grey  
Short pistol handle — red/yellow  
Long pistol handle — black/grey  
Long pistol handle — red/yellow  
Short pistol handle — black/grey  
Short pistol handle — red/yellow  
Long pistol handle — black/grey  
Long pistol handle — red/yellow  
And  
Clockwise  
For use with front rotary  
mechanism or side rotary  
mechanism CCP2-SM on  
the switch’s right side  
Type 1, 4X, 12  
Counterclockwise  
Use only if installing side  
rotary mechanism CCP2-  
SM on the switch’s left  
side  
Shafts (12 mm)  
CCP2-SH2-225  
CCP2-SH2-425  
Length  
225 mm  
425 mm  
NFPA 79  
compliant handle  
Color  
CCP2-NFPA-2  
Red  
11-32  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Or  
Description — 3-pole switches  
Flange handle rod only, cannot be used with side or  
operator  
front rotary mechanisms  
Red/black, painted handle  
Chrome handle  
Rating  
Type 1, 3R and 12  
Type 4X  
CCP2-FLR2-21  
CCP2-FLR2-21X  
Or  
Description - 3-pole switches only,  
cannot be used with side or front  
rotary mechanisms  
Flange handle  
cable operator  
Rating  
Type 1, 3R and 12  
Type 4X  
CCP2-FLC2-36  
CCP2-FLC2-36X  
CCP2-FLC2-60  
CCP2-FLC2-60X  
CCP2-FLC2-120  
CCP2-FLC2-120X  
36“ cable, red/black painted handle  
36“ cable, chrome handle  
60“ cable, red/black painted handle  
60“ cable, chrome handle  
120“ cable, red/black painted handle  
120“ cable, chrome handle  
And  
Type 1, 3R and 12  
Type 4X  
Type 1, 3R and 12  
Type 4X  
Terminal shrouds  
CCP2-TS2-3  
Description  
3-pole terminal shroud with phase shields, 1 per pack  
Phase barriers  
Description  
CCP2-PB2  
Phase barriers, 2 per pack  
And  
Control wire  
terminals  
Description  
1/4” quick-connect control wire terminals - mounts on installed lug (cannot be used  
with lug CCP2-L2-1), 12 per pack  
CCP2-CWK2  
Auxiliary contacts Description  
CCP2-AUX-S  
NO/NC, 5 A, 240 V - Can be mounted on right or left side  
Handle extension  
CCP2-HEX  
Description  
Handle extension to facilitate operating 1-, 2 and 3-pole switches. Cannot be used  
when side or front rotary mechanisms or flange handle rod or cable operators are  
installed.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-33  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Ordering a complete switch installation  
400 A CCP2 switches  
For a complete installation, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
CCP2-1-400CF  
1
CCP2-2-400CF  
CCP2-3-400CF  
400  
2
3
And  
Lug kits  
Description  
CCP2-L4-1  
Stainless steel lug, 75° Cu only, 500 kcmil-3, 1 per pack  
Aluminum lug, 75° Cu only, 500 kcmil-3, 1 per pack  
CCP2-L4-1A  
CCP2-L4B-3  
CCP2-L4B-3A  
CCP2-MW6-6  
CCP2-L6-3  
Stainless steel lug, 75° Cu only, 750-500 kcmil, 3 per pack, includes terminal shroud  
Aluminum lug, 75°C Cu/Al, 750-500 kcmil, 3 per pack, includes terminal shroud  
6-port multi-wire lug, 75°C Cu/Al, 1/0-14, 3 per pack, includes terminal shroud  
2-port stainless steel lug, 75° Cu only, 500 kcmil-2, 3 per pack, includes terminal shroud  
2-port aluminum lug kit, 75° Cu/Al only, 500 kcmil-2, 3 per pack, includes terminal shroud  
And  
CCP2-L6-3A  
Rotary  
mechanisms  
Description  
CCP2-SM  
Side rotary mechanism - mounts on left or right side of 1-, 2- and 3-pole switches  
Front rotary mechanism - mounts only on 3-pole switches, requires clockwise  
rotating handle  
CCP2-RM4  
And  
Rotation - must match  
Rotary handles  
CCP2-H4X-B3  
CCP2-H4X-R3  
CCP2-H4X-B4  
CCP2-H4X-R4  
CCP2-H4X-B3L  
CCP2-H4X-R3L  
CCP2-H4X-B4L  
CCP2-H4X-R4L  
Description  
switch rotation  
Rating  
Short pistol handle — black/grey  
Short pistol handle — red/yellow  
Long pistol handle — black/grey  
Long pistol handle — red/yellow  
Short pistol handle — black/grey  
Short pistol handle — red/yellow  
Long pistol handle — black/grey  
Long pistol handle — red/yellow  
And  
Clockwise  
For use with front rotary  
mechanism or side rotary  
mechanism CCP2-SM on  
the switch’s right side  
Type 1, 4X, 12  
Counterclockwise  
Use only if installing side  
rotary mechanism CCP2-  
SM on the switch’s left  
side  
Shafts (12 mm)  
CCP2-SH2-225  
CCP2-SH2-425  
Length  
225 mm  
425 mm  
NFPA 79  
compliant handle  
Color  
CCP2-NFPA-2  
Red  
11-34  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Or  
Flange handle rod Description - 3-pole switches only, cannot be used with side  
operator  
or front rotary mechanisms  
Red/black, painted handle  
Chrome handle  
Rating  
Type 1, 3R, 12  
Type 4X  
CCP2-FLR2-21  
CCP2-FLR2-21X  
Or  
Flange handle  
cable operator  
Description - 3-pole switches only, cannot be used with side  
or front rotary mechanisms  
Rating  
Type 1, 3R, 12  
Type 4X  
CCP2-FLC2-36  
CCP2-FLC2-36x  
CCP2-FLC2-60  
CCP2-FLC2-60x  
CCP2-FLC2-120  
CCP2-FLC2-120x  
36“ cable, red/black painted handle  
36“ cable, chrome handle  
60“ cable, red/black painted handle  
60“ cable, chrome handle  
120“ cable, red/black painted handle  
120“ cable, chrome handle  
And  
Type 1, 3R, 12  
Type 4X  
Type 1, 3R, 12  
Type 4X  
Terminal shrouds  
CCP2-TS6-3  
Description  
3-pole terminal shroud with phase shields, 1 per pack  
Description  
Phase barriers  
CCP2-PB6  
Phase barriers, 2 per pack  
And  
Auxiliary contacts Description  
CCP2-AUX-S  
NO/NC, 5 A, 240 V - Can be mounted on right or left side  
Handle extension  
Description  
Handle extension to facilitate operating 1-, 2 and 3-pole switches. Cannot be used  
when side or front rotary mechanisms, or flange handle rod and cable mechanisms  
are installed.  
CCP2-HEX  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-35  
Eaton.com/bussmannseries  
11 — Disconnect switches  
CUBEFuse Compact Circuit Protector Base  
Agency information  
2011/65/EU  
•ꢀ  
UL 98 Listed, Guide WHTY, File E302370  
•ꢀ  
cULus to Canadian Standard 22.2 No. 4, Guide WHTY7,  
File E302370  
•ꢀ  
RoHS compliant  
•ꢀ  
CE  
Lineside bolt-on bus connector and torque  
•ꢀ  
Bolt-mounted design into Quik-Spec Coordination Panelboard bus  
•ꢀ  
#10-32 UNC hex flange Phillips screw; 2.8 N•m (25 lb-In)  
Loadside box lug terminal conductor data  
•ꢀ  
See conductor table for details  
1-Pole  
2-Pole  
3-pole  
CCP2B-3-_CF  
Loadside fork terminal  
CCP2B-1-_CF  
CCP2B-2-_CF  
•ꢀ  
Max. 30 A suitable for use with #8-32 UNC screw  
Description  
Lockout/tagout  
The revolutionary Bussmann series Compact Circuit Protector  
Base (CCP2B) with CUBEFus™ is a UL 98 horsepower rated fused  
branch circuit disconnect. Primarily used in the Bussmann series  
Quik-Spec™ Coordination Panelboard, the CCP2B with CUBEFuse  
simplifies selective coordination for code complaince along with a  
lockout/tagout feature for isolating individual branch circuit loads to  
promote safe work practices.  
•ꢀ  
1/4” lock  
Local open fuse indication  
•ꢀ  
Light illumination requires closed circuit and minimum 90 volts  
Carton quantity and shipping weight  
Features  
Item  
Poles  
lbs (kg)  
1.7 (0.77)  
2.6 (1.18)  
•ꢀ  
Uses finger-safe, current-limiting Class CF CUBEFuse with Class  
up to 60 amp switches  
70 to 100 amp switches  
6
6
J performance available, time-delay or fast-acting versions from 1  
to 100 amps  
•ꢀ  
Patented amp rating rejection feature helps prevent overfusing  
Environmental data  
•ꢀ  
High 200 kA short-circuit current rating  
ꢀ  
Storage and operating temperature -20°C to 75°C**  
•ꢀ  
Disconnect rated to provide a means for load isolation  
**For fuse performance under or above 25°C, consult fuse performance derating  
charts.  
•ꢀ  
2- and 3-pole versions full voltage rated at 600 Vac  
•ꢀ  
Up to 125 Vdc ratings  
Available Bussmann series fuses  
•ꢀ  
UL 98 Listed for branch circuit disconnect  
UL fuse  
class  
Data sheet  
no.  
•ꢀ  
1-, 2- and 3-pole versions are horsepower rated  
Type/description  
Volts  
•ꢀ  
Listed to UL and cULus  
Indicating time-delay, Low-Peak  
CUBEFuse (6-100 A)  
•ꢀ  
Open fuse indication lamp per pole speeds troubleshooting  
600 Vac/  
300 Vdc  
9000  
2147  
Non-indicating time-delay,  
Low-Peak CUBEFuse (1-100 A)  
•ꢀ  
Additional open fuse indication can be provided by using the time-  
delay indicating CUBEFuse in ratings from 6 to 100 A  
CF  
Non-indicating fast-acting  
CUBEFuse (1-100 A)  
•ꢀ  
Built-in switch/fuse interlock prevents removing or installing a fuse  
while energized  
600 Vac/dc  
•ꢀ  
Permanent lockout/tagout and lock-on provision usign a 1/4” lock  
Lineside bolt-on bus connector  
Specifications:  
Switch amp ratings and rejection breaks  
Switch ON and OFF symbols  
Lockout/tagout provision  
•ꢀ  
15, 20, 30, 40, 50, 60, 70, 90 and 100 A  
Poles  
•ꢀ  
1-, 2- and 3-poles  
Switch handle  
Volts  
•ꢀ  
600 Vac (or less)  
Local open fuse indication light  
•ꢀ  
125 Vdc*  
CUBEFuse base  
* Switch amp rating and installed fuse amp rating dependent, see catalog number  
table for details.  
Loadside box lug and fork terminals  
Data sheet no: 1161  
11-36  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Catalog numbers and ratings  
Box lug conductor data  
AWG  
Accepts  
Voltage CUBEFuse  
ratings amp range SCCR (Vac)†††  
Torque  
Quantity N•m (lb-in)  
Catalog  
numbers  
Hp ratings  
Wire type  
range  
Class  
Poles  
15 to 60 A switches  
347 Vac,  
4-6  
8-18  
3.95 (35)  
2.26 (20)  
3.39 (30)  
Stranded, Class B  
to K  
Stranded, Class B/C  
Stranded, Class K  
CCP2B-1-15CF  
CCP2B-2-15CF  
1
0.5 Hp @ 120 V  
Single  
Dual  
125 Vdc  
600 Vac,  
125 Vdc  
2
3
1.5 Hp @ 240 V  
1 to 15  
1 to 20  
1 to 30  
1 to 40  
1 to 50  
1 to 60  
1 to 70  
1 to 90  
1 to 100  
6-8  
3 Hp @ 240 V  
5 Hp @ 480 V  
7.5 Hp @ 600 V  
2.26 (20)  
Stranded, Class B  
CCP2B-3-15CF  
600 Vac  
10-18  
to K  
Solid  
75°C Cu  
10-18  
Single/dual  
Single  
2.26 (20)  
3.39 (30)  
347 Vac,  
125 Vdc  
600 Vac,  
125 Vdc  
CCP2B-1-20CF  
CCP2B-2-20CF  
1
2
0.75 Hp @ 120 V  
2 Hp @ 240 V  
4-18  
6-18  
4-18  
6-18  
Stranded, UL ferrule,  
Class B/C  
Twin†  
Single  
Stranded, UL  
ferrule, Class K  
2.82 (25)  
3 Hp @ 240 V  
7.5 Hp @ 480 V  
10 Hp @ 600 V  
Twin†  
CCP2B-3-20CF  
3
600 Vac  
70 to 100 A switches  
12-18  
10  
8
4-6  
1-3  
2.26 (20)  
2.82 (25)  
4.52 (40  
5.08 (45)  
6.21 (55)  
347 Vac,  
125 Vdc  
600 Vac,  
125 Vdc  
CCP2B-1-30CF  
CCP2B-2-30CF  
1
2
1.5 Hp @ 120 V  
3 Hp @ 240 V  
Stranded, Class B  
to K  
Single  
5 Hp @ 240 V  
15 Hp @ 480 V  
10 Hp @ 600 V  
CCP2B-3-30CF  
3
600 Vac  
Stranded, Class B  
to K  
3-12  
Dual  
Single  
Twin†  
3.95 (35)  
347 Vac,  
125 Vdc  
600 Vac,  
125 Vdc  
CCP2B-1-40CF  
CCP2B-2-40CF  
1
2
2.0 Hp @ 120 V  
3 Hp @ 240 V  
12-18  
10  
2.26 (20)  
3.95 (35)  
4.52 (40)  
2.26 (20)  
2.82 (25)  
2.26 (20)  
2.26 (20)  
2.26 (20)  
3.39 (30)  
5.08 (45)  
2.26 (20)  
3.39 (30)  
2.26 (20)  
Stranded, UL  
ferrule, Class B/C  
1-8  
10-18  
75°C Cu  
7.5 Hp @ 240 V  
20 Hp @ 480 V  
10 Hp @ 600 V  
CCP2B-3-40CF  
3
600 Vac  
6-8  
10-18  
10-18  
8-18  
1-6  
Single  
Dual  
347 Vac,  
125 Vdc*  
600 Vac,  
125 Vdc*  
Solid  
CCP2B-1-50CF  
CCP2B-2-50CF  
1
2
3.0 Hp @ 120 V  
5 Hp @ 240 V  
200 kA  
AC  
Single  
Dual  
Class K  
100 kA  
DC  
7.5 Hp @ 240 V  
20 Hp @ 480 V  
10 Hp @ 600 V  
3-10  
8-18  
1-6  
CCP2B-3-50CF  
3
600 Vac  
Single  
Class K, UL ferrule  
347 Vac,  
125 Vdc*  
600 Vac,  
125 Vdc*  
CCP2B-1-60CF  
CCP2B-2-60CF  
1
2
3.0 Hp @ 120 V  
7.5 Hp @ 240 V  
6-18  
Twin  
Two stranded conductors placed in one UL Listed twin ferrule.  
Dimensions — in (mm)  
7.5 Hp @ 240 V  
20 Hp @ 480 V  
10 Hp @ 600 V  
CCP2B-3-60CF  
3
600 Vac  
2.7  
3.0  
0.5  
1.0  
(76)  
(69)  
(13)  
2.0  
(25)  
(51)  
347 Vac,  
125 Vdc  
600 Vac,  
125 Vdc  
CCP2B-1-70CF  
CCP2B-2-70CF  
1
2
3.0 Hp @ 120 V  
7.5 Hp @ 240 V  
15 Hp @ 240 V  
30 Hp @ 480 V  
40 Hp @ 600 V  
CCP2B-3-70CF  
3
600 Vac  
3.9  
(99)  
15-60 A  
347 Vac,  
CCP2B-1-90CF  
CCP2B-2-90CF  
1
2
5.0 Hp @ 120 V  
10 Hp @ 240 V  
125 Vdc**  
600 Vac,  
125 Vdc**  
20 Hp @ 240 V  
50 Hp @ 480 V  
40 Hp @ 600 V  
CCP2B-3-90CF  
3
600 Vac  
2.9  
3.0  
(73)  
Ø 0.2  
(76)  
1.0  
0.03  
(0.8)  
(Ø 5.1)  
2.0  
2.7  
(25)  
(51)  
(70)  
347 Vac,  
CCP2B-1-100CF  
CCP2B-2-100CF  
1
2
5.0 Hp @ 120 V  
10 Hp @ 240 V  
125 Vdc**  
0.54  
(14)  
600 Vac,  
125 Vdc**  
20 Hp @ 240 V  
50 Hp @ 480 V  
40 Hp @ 600 V  
CCP2B-3-100CF  
3
600 Vac  
5.3  
70-100 A  
(133)  
1 and 3 A indicating CUBEFuse not available. Correct fit with CCP2B discon-  
nect requires indicating CUBEFuse with date code R38 or later.  
Not for use with motors.  
††  
††† Indicating or non-indicating time-delay CUBEFuse only.  
*
125 Vdc for installed fuse amp ratings up to 40 A. 24 Vdc for installed fuse  
amp ratings from 45 to 60 A.  
125 Vdc for installed fuse amp ratings up to 80 A, 24 Vdc for installed fuse  
amp ratings from 90 to 100 A.  
**  
3.4  
(86)  
For details on the CCP2B and its use in the Quik-Spec Coordination  
Panelboard, see data sheet no. 1160.  
Data sheet no: 1161  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-37  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Compact Circuit Protector (cat. no. CCP2)  
For use with Class CC, Supplemental and IEC 10x38 mm fuses  
Class CC and midget CCP contents  
Section page  
Description and specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . .39-40  
Catalog numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41  
Conductor information and available fuses . . . . . . . . . . . . . . . . . . . . . 42  
Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42  
Accessories  
Multi-wire lug kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 43  
Selector and pistol handles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
NFPA 79 compliant handle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
Shafts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44  
Auxiliary contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45  
PLC fuse monitor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46-47  
How to order tables  
Clockwise rotary operated switches . . . . . . . . . . . . . . . . . . . . . . . .48-49  
Switches only . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50  
Counterclockwise rotary operates switches . . . . . . . . . . . . . . . . . . . . 51  
CCP2 switch  
CCP2 right front rotary switch  
CCP2 left front rotary switch  
CCP2 right side rotary switch  
CCP2 left side rotary switch  
11-38  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL Supplemental and IEC 10x38 mm fuse versions  
•ꢀ  
Catalog symbols  
•ꢀ UL 508 Listed, Guide NRNT, File E320230  
•ꢀ cULus Certified 22.2 No. 14-05  
•ꢀ IEC 60947-3 AC-23A  
Symbol  
Fuse type  
Class CC  
UL sup./IEC 10x38  
Class CC Vdc  
UL sup./IEC 10x38 Vdc  
Class CC  
Description  
CCP2-(poles)-30CC  
CCP2-(poles)-30M  
CCP2-1-DCC  
CCP2-1-DCM  
CCP2R-(pole)-30CC  
CCP2R-(pole)-30M  
CCP2RL-(pole)-30CC Class CC  
CCP2RL-(pole)-30M UL sup./IEC 10x38  
CCP2S-(pole)-30CC  
CCP2S-(pole)-30M  
CCP2SL-(pole)-30CC Class CC  
Switch only  
•ꢀ  
•ꢀ  
DC voltage UL Class CC version (CCP2-1-DCC)  
1-pole switch only  
•ꢀ UL 508 Listed, cULus 22.2, No. 1405  
DC IEC 10x38 version (CCP2-1-DCM)  
Right front rotary switch  
Left front rotary switch  
Right side rotary switch  
Left side rotary switch  
UL sup./IEC 10x38  
•ꢀ IEC 60947-3, DC-23A  
•ꢀ  
•ꢀ  
RoHS compliant  
CE  
Class CC  
UL sup./IEC 10x38  
Conductors/terminals  
•ꢀ  
75°C Cu/Al, see conductor tables for size, type and torque  
information  
CCP2SL-(pole)-30M UL sup./IEC 10x38  
Description  
•ꢀ  
Box lug, single/dual conductor  
The revolutionary next generation Bussmann™ series Compact  
Circuit Protector (cat. no. CCP2) fused disconnect switch is 3/5 the  
footprint of a traditional fusible switch and provides up to a high 200  
kA Short-Circuit Current Rating (SCCR) to help improve panel and  
assembly SCCR.  
•ꢀ  
Fork terminal suitable for line, load or accessory connection  
•ꢀ  
Multi-wire lug kit — see accessories for details  
Storage and operating temperature  
•ꢀ  
- 20°C to 75°C (-4°F to 167°F)*  
The 35 mm DIN-Rail mount CCP is available in a variety of  
configurations to meet many application needs including rotary  
operation.  
* For fuse performance under or above 25°C, consult fuse performance derating  
charts in the Bussmann Division publication no. 3002, titled Selecting Protective  
Devices (SPD)  
Application flexibility is extended with an optional multi-wire lug kit,  
with finger-safe shrouds, that provides three additional wire ports on  
each pole for power distribution applications.  
Lockout/tagout provisions  
•ꢀ  
Switch only — 4 mm lock or Brady pin-out device part number  
90850  
Other accessories include a PLC interface device for open fuse  
monitoring and NO/NC auxiliary contacts that easily integrate into  
many monitoring systems.  
•ꢀ  
Switch with rotary operating mechanism — 1/4” lock  
Front and side rotary operated versions are easily applied for  
through-the-door or through the left or right side operation to  
enhance safety.  
Minimum enclosure size  
•ꢀ  
10” x 8” x 6” (254 x 203 x 152 mm)  
Mounting  
Ratings  
•ꢀ  
35 mm DIN-Rail  
•ꢀ  
Volts  
600 Vac (UL® Class CC)  
•ꢀ  
Local open fuse indication minimum voltage**  
•ꢀ  
240 Vac (UL Supplemental)  
•ꢀ  
90 Vac for AC switches  
•ꢀ  
400 Vac (IEC 10x38 mm)  
•ꢀ  
12 Vdc for DC switches  
•ꢀ  
80 Vdc (DC Class CC, DC UL Supplemental/IEC)  
** Open fuse indication requires an open fuse to be in the CCP2 and the switch  
in the ON position.  
•ꢀ  
Amps  
•ꢀ  
30 A (UL)  
Accessories  
•ꢀ  
32 A (IEC)  
•ꢀ  
Multi-wire lug kit with terminal shrouds  
•ꢀ  
SCCR  
•ꢀ  
Selector and pistol handles for use with rotary operated switches  
•ꢀ  
200 kA (UL Class CC)  
•ꢀ  
8 mm shafts for use with selector and pistol handles  
•ꢀ  
10 kA (UL Supplemental)  
•ꢀ  
Auxiliary contacts  
•ꢀ  
120 kA (IEC 10x38 mm max)  
•ꢀ  
PLC fuse monitor  
•ꢀ  
20 kA (DC Class CC/UL)  
•ꢀ  
10 kA (DC UL Supplemental/IEC)  
Poles  
•ꢀ  
1-, 2- and 3-poles catalog number dependent  
Agency information  
•ꢀ  
UL Class CC fuse versions  
•ꢀ UL 98 Listed, Guide WHTY, File E302370  
•ꢀ cULus to Canadian Standard 22.2 No. 4-04, UL Guide WHTY7,  
File 302370  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-39  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Features  
•ꢀ  
Extremely compact (18 mm wide per pole ) design  
•ꢀ  
High SCCR up to 200 kA (UL Class CC) and 120 kA (IEC)  
•ꢀ  
Disconnect rated for load isolation  
•ꢀ  
Full voltage rated up to 600 Vac or 80 Vdc  
•ꢀ  
UL 98 Listed Class CC version is horsepower rated and suitable  
for branch circuit protection and disconnect  
•ꢀ  
IEC 10x38 version complies with IEC 60947-3 and suitable for  
branch circuit protection and disconnect  
•ꢀ  
Suitable for global installations, the switches comply with UL,  
cULus and IEC standards accepting UL Class CC, Supplemental  
or IEC aM and gG/gL fuses  
•ꢀ  
Open fuse indication  
•ꢀ Standard local open fuse indicating light for each pole  
•ꢀ Optional PLC fuse monitor can be utilized to signal a PLC and  
open a contactor to de-energize all phases, if required  
IP20 finger-safe with 10 AWG (6 mm2) or larger wire (box lug  
terminals only)  
•ꢀ  
•ꢀ  
Built-in switch interlock prohibits removing the fuse under load  
•ꢀ  
Padlockable handle for lockout/tagout  
•ꢀ 4 mm lock for switch only  
•ꢀ 1/4” lock for rotary operated switches  
•ꢀ  
Rotary operated versions provide for through-the-door and  
through-the-side operation flexibility and enhanced safety with:  
•ꢀ Right front switch operation  
•ꢀ Left front switch operation  
•ꢀ Right side switch operation  
•ꢀ Left side switch operation  
Right front rotary operated CCP2 switch with PLC fuse monitor.  
•ꢀ  
Optional selector and pistol handles available for use with rotary  
operated versions  
Rotary operating switch versions  
•ꢀ  
Multi-wire lug kit with terminal shrouds allows for power  
distribution to multiple loads. Each lug has three ports rated for  
single and dual wires (see lug kit in accessories for conductor and  
torque details).  
Switch handle  
(ganged on 2- and  
Open fuse  
indicating light  
3-pole versions)  
Left front rotary switch  
Right front rotary switch  
Fuse access door  
Clockwise operating handles  
Clockwise operating handles  
Fork terminal  
Box lug terminal  
Lockout/tagout  
provision  
Right side rotary switch  
Left side rotary switch  
Clockwise operating handles  
Counterclockwise operating  
handles  
11-40  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Catalog numbers  
Max horsepower rating (Vac)  
Wire type/  
size*  
Catalog no.  
Poles Description  
Amps  
Volts  
SCCR  
120  
240  
480  
600  
Class CC  
CCP2-1-30CC  
CCP2-2-30CC  
CCP2-3-30CC  
CCP2R-2-30CC  
CCP2R-3-30CC  
CCP2RL-2-30CC  
CCP2RL-3-30CC  
CCP2S-2-30CC  
CCP2S-3-30CC  
CCP2SL-2-30CC  
CCP2SL-3-30CC  
1
347 Vac  
600 Vac  
1/2  
2
3
2
3
2
3
2
3
2
3
5
7. 5  
2
3
2
3
2
3
2
3
2
3
Switch only  
3/4  
Switch with right  
front rotary operation  
600 Vac  
600 Vac  
600 Vac  
600 Vac  
75°C Cu/Al  
18-4 AWG  
3/4  
5
5
7. 5  
30 A  
200 kA  
Switch with left front  
rotary operation  
Fork terminal††  
3/4  
7. 5  
5
Switch with right side  
rotary operation  
3/4  
7. 5  
5
Switch with left side  
rotary operation  
3/4  
7. 5  
UL Supplemental and IEC 10x38 mm  
CCP2-1-30M  
1
2
3
2
3
2
3
2
3
2
3
CCP2-2-30M  
Switch only  
CCP2-3-30M  
CCP2R-2-30M  
CCP2R-3-30M  
CCP2RL-2-30M  
CCP2RL-3-30M  
CCP2S-2-30M  
CCP2S-3-30M  
CCP2SL-2-30M  
CCP2SL-3-30M  
Switch with right  
front rotary operation  
75°C Cu/Al  
18-4 AWG  
UL 240 Vac†  
IEC 400 Vac†  
UL 30 A  
IEC 32 A**  
UL 10 kA†  
IEC 120 kA†  
Switch with left front  
rotary operation  
Fork terminal††  
Switch with right side  
rotary operation  
Switch with left side  
rotary operation  
Single-pole DC switches  
CCP2-1-DCC  
1
UL Class CC  
30 A  
30 A  
80 Vdc†  
80 Vdc†  
20 kA†  
10 kA†  
75°C Cu/Al  
18-4 AWG  
UL supplemental  
CCP2-1-DCM  
1
Fork terminal††  
IEC 10x38  
32 A**  
* See box lug terminal conductor data table for details.  
**32 A Class aM, 25 A Class gG.  
† SCCR may be lower, refer to installed fuse data sheet for interrupting rating at applied voltage.  
††Fork terminal with a 4.3 mm gap for a #8-32 stud, 30 A max, insulated flange, wire size 12-10 AWG.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-41  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Box lug terminal conductor data  
Left front and right front rotary switches  
78  
3.1  
AWG  
Torque  
53  
99  
2.1  
35  
1.4  
Type range Class  
Quantity N•m (lb-in)  
Single  
Dual  
3.9  
49  
1.9  
18  
0.7  
4-18 Stranded, Class B to K  
6-8  
6-8  
10-18 Stranded, Class B to K  
10-18 Solid  
2.26 (20)  
3.39 (30)  
Stranded, Class B/C  
Stranded, Class K  
Dual  
2.26 (20)  
Single/dual  
Single  
Twin†  
Cu  
93  
3.7  
4-18  
Stranded, UL ferrule, Class B/C  
6-18  
3.39 (30)  
2.82 (25)  
4-18  
Single  
Twin†  
Single  
Stranded, UL ferrule, Class K  
6-18  
4-8  
2.26 (20)  
2.82 (25)  
2.26 (20)  
80  
3.1  
Al  
6
8
Stranded  
Dual  
78  
99  
[3.9]  
[3.1]  
53  
[2.1]  
35  
[1.4]  
49  
[1.9]  
18  
[0.7]  
Two stranded conductors placed in one UL Listed twin ferrule.  
Available Bussmann series fuses  
Data  
sheet  
no.  
Fuse  
class  
93  
[3.7]  
Type/description  
LP-CC time-delay  
FNQ-R time-delay  
KTK-R fast-acting  
FNM time-delay  
FNQ time-delay  
KTK fast-acting  
BAF fast-acting  
KLM fast-acting  
Volts  
93  
[3.7]  
600 Vac/300 Vdc*  
600 Vac/300 Vdc  
600 Vac  
1023  
1014  
1015  
2028  
1012  
1011  
CC  
250 Vac  
500 Vac  
80  
[3.1]  
M
600 Vac  
250 Vac  
2011  
2020  
720115  
600 Vac/dc  
500 V (400 V@32 A)  
Left side and right side rotary switches  
gG/gL C10G  
aM C10M  
78  
3.1  
53  
2.1  
500 V (400 V@20@25 A) 720115  
35  
1.4  
18  
0.7  
49  
1.9  
* 1/2 to 2-1/2 and 20 to 30 A are 300 Vdc, 2-8/10 to 15 A are 150 Vdc.  
93  
3.7  
Dimensions – mm (in)  
Switch  
53  
2.1  
35  
1.4  
49  
1.9  
18  
0.7  
80  
3.1  
78  
3.1  
53  
2.1  
35  
1.4  
49  
1.9  
18  
0.7  
93  
3.7  
93  
3.7  
80  
3.1  
80  
3.1  
11-42  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Installed on CCP2-3-xx  
Multi-wire lug kit  
Catalog number  
•ꢀ  
CCP2-MW1-3  
Description  
The multi-wire lug kit permits expanding each box lug terminal  
on the switch into a three-port terminal for power distribution  
applications.  
Each multi-wire lug kit comes with three (3) three-port lugs and  
three terminal shrouds. Shrouds provide finger-safe protection when  
properly installed.  
Lugs may be mounted on either the loadside or lineside to meet  
various application needs.  
Ports on any one lug accept any conductor combination listed, e.g.,  
one of the three ports may have dual 14 AWG wires and the other  
two ports single 10 AWG wires.  
Ratings  
Multi-wire lugs mount in switch box lug terminals to provide three  
additional wire ports per pole. Lugs can be mounted on the switch  
lineside or loadside. Each multi-wire lug kit comes with three lugs  
and three shrouds.  
•ꢀ  
Volts 600 V  
•ꢀ  
Amps 60 A max  
•ꢀ  
SCCR 200 kA  
Agency information  
Wire insulation strip lengths  
•ꢀ  
UL Recognized (lug only)  
1/8” Allen  
head screw  
•ꢀ  
RoHS compliant  
Storage and operating temperature  
1 = 11/16”  
2 = 1-1/8”  
3 = 1-9/16”  
•ꢀ  
- 20°C to 75°C (-4°F to 167°F)  
Multi-wire lug conductor information  
•ꢀ  
75°C Cu/AL  
•ꢀ  
AWG size and quantity per port - see table below  
Strip back wire insulation to the lengths as indicated in the  
illustration above and the table below.  
AWG  
Type range  
Torque  
N•m (lb-in)  
Class  
Quantity  
4-6  
3.95 (35)  
2.82 (25)  
2.26 (20)  
2.26 (20)  
2.82 (25)  
2.26 (20)  
Lug port  
Strip wire insulation back (inch)  
Cu/Al  
8
Stranded, Class B/C  
Single  
1
2
3
11/16  
1-1/8  
10-14  
Stranded, Class B/C  
Solid  
Single/dual*  
Single  
10-14  
1-9/16  
Cu  
8
UL ferrule, Class B to K Single/twin†  
10-14  
* Dual wire to be same size and type.  
Two stranded conductors placed in one UL Listed twin ferrule.  
CCP2 box lug torque for multi-wire lug  
•ꢀ  
4.52 N•m (40 lb-in)  
Terminal shroud accessory  
Terminal shrouds are available without multi-wire terminals.  
Catalog no.  
Description  
CCP2-TS1-3  
Pack of three  
Wiring versatility is provided by single/dual rated box lug terminals  
on the switch, or by the three-port multi-wire lug kit thats also  
single/dual wire rated.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-43  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Selector and pistol handles  
Selector handles  
Catalog symbol  
•ꢀ  
CCP2-H4X-_  
Description  
Selector and pistol handles for use with any 2- and 3-pole CCP2  
rotary operated switch. Both selector and pistol handles are available  
in black/grey and red/yellow colors and clockwise/counterclockwise  
operating modes. Applying clockwise and counterclockwise  
operation depends upon the CCP2 rotary switch configuration.  
Installation requires an 8 mm shaft (ordered separately).  
Pistol handles  
Each handle is rated NEMA 4X and capable of accepting up to three  
(3) 1/4” diameter shank locks for lockout/tagout in the OFF position.  
They can also be field configured for lock-on.  
In application, only the clockwise operating handles in combination  
with either the left front or right front rotary switches provide a door  
interlock means to ensure the enclosure door remains shut during  
lockout/tagout or lock-on. Both clockwise and counterclockwise  
operating handles when mounted on the enclosures left or right side  
do NOT provide a door interlock means.  
Handle shafts  
See the catalog number table below for applicable rotary switch,  
handle and shaft combinations.  
Agency information  
•ꢀ  
UL Listed, Guide DIHS, File E140305  
•ꢀ  
NEMA 4X rating  
•ꢀ  
RoHS compliant  
•ꢀ  
CE  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
NFPA 79 compliant handle  
Catalog number  
Packaging  
•ꢀ  
Each handle is packaged individually  
•ꢀ  
CCP2-NFPA-1  
Description  
Handle shafts  
NFPA 79 compliant handle mounts on  
the shaft of front rotary operated switch  
installations and provide a lockout means  
independent of the door position.  
Catalog symbol  
•ꢀ  
CCP2-SH1-_  
Description  
Eight millimeter square shafts available in 290 and 490 millimeter  
(11.5 and 19.3 inch) lengths. Shafts are indexed to ensure handle/  
switch orientation for correct operation. Shafts are cut to length  
when installed.  
Packaging  
•ꢀ  
Each shaft is packaged separately  
For these switch  
catalog numbers  
Order these handle catalog numbers  
(description)  
Description/operation  
Order either shaft catalog number  
CCP2R-(pole)-30CC  
CCP2R-(pole)-30M  
CCP2RL-(pole)-30CC  
CCP2RL-(pole)-30M  
CCP2S-(pole)-30CC  
CCP2S-(pole)-30M  
Right front rotary, clockwise  
• CCP2-H4X-B1 (selector, black/grey)  
• CCP2-H4X-R1(selector, red/yellow)  
• CCP2-H4X-B2 (pistol, black/grey)  
• CCP2-H4X-R2 (pistol, red/yellow)  
Left front rotary, clockwise  
Right side rotary, clockwise  
• CCP2-SH1-290 (11.5”/290 mm)  
• CCP2-SH1-490 (19.3”/490 mm)  
• CCP2-H4X-B1L (selector, black/grey)  
• CCP2-H4X-R1L (selector, red/yellow)  
• CCP2-H4X-B2L (pistol, black/grey)  
• CCP2-H4X-R2L (pistol, red/yellow)  
CCP2SL-(pole)-30CC  
Left side rotary, counterclockwise  
CCP2SL-(pole)-30M  
11-44  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Installed on a CCP2-3-xx  
Auxiliary contacts  
Note: CCP2-AUX CANNOT be mounted on the right front and right  
side rotary operated versions.  
Catalog number  
•ꢀ  
CCP2-AUX  
Description  
NO+NC contact output to indicate the  
switching mechanism status on the  
CCP2. A single unit can be mounted  
on any 1-, 2- or 3-pole CCP2 switch  
and the left front/left side rotary  
operated switches.  
Ratings  
•ꢀ  
Amps up to 5 A  
•ꢀ  
Volts up to 240 Vac  
•ꢀ  
NC/NO contacts are closed/open when the CCP2 switch is in the  
“ON” position (closed)  
Dimensions — in  
Description  
Max per CCP2*  
Signal output  
1.8  
Auxiliary contacts NO+NC  
for switch status  
1 per CCP2  
(1-, 2- or 3-pole)  
5 A / 240 Vac  
* The CCP2-AUX CANNOT be mounted on the right front and right side rotary  
operated versions.  
De-energize all circuits and follow all prevailing safety procedures before  
installing or removing the CCP2-AUX.  
2.6  
Agency information  
STRIP  
•ꢀ  
1.9  
UL 98 Recognized, Guide WHTY2, File E155130  
33 NO  
41 NC  
34 NO  
42 NC  
•ꢀ  
cURus to Canadian Standard 22.2 No. 4-04  
•ꢀ  
IP20 finger-safe in installed state  
•ꢀ  
RoHS compliant  
0.19  
•ꢀ  
3.7  
CE  
0.3  
Wiring  
75°C Cu, 20-16 AWG (0.5 to 1.5 mm2) wire  
•ꢀ  
•ꢀ  
Torque 0.56 N•m (5 lb-in)  
Packaging  
•ꢀ  
The CCP2-AUX is packaged individually  
Installation technique  
•ꢀ  
Mounts on the CCP2s right side ONLY and mechanically  
interlocks with the CCP2 switch handle with provided hardware.  
The CCP2-AUX CANNOT be mounted on the right front and right  
side rotary operated versions.  
Storage and operating temperature  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
CCP2-AUX auxiliary contacts mounted on a 3-pole CCP2 switch.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-45  
Eaton.com/bussmannseries  
11 — Disconnect switches  
PLC fuse monitor  
Wiring  
•ꢀ  
For power, signal and ground connections use shielded twisted  
Catalog number  
pair 22-24 AWG (0.34-0.25 mm2) 300 V rated wire  
•ꢀ  
CCP2-PLC-IND  
Packaging  
Description  
•ꢀ  
The CCP2-PLC-IND is packaged individually  
A resettable three-phase  
•ꢀ  
Includes 0.110” (2.8 mm) quick connects for power, signal and  
ground connections  
fuse monitor that integrates  
with the I/O card in a  
Programmable Logic  
Installation technique  
Controller (PLC). A single  
•ꢀ  
Mounts on the left side ONLY of the CCP2 and mechanically  
unit can be mounted on  
interlocks with the CCP2 switch handle with hardware provided.  
The CCP2-PLC-IND CANNOT be mounted on the left front/  
left side rotary operated versions or if the multi-wire lug kit is  
installed.  
any 1-, 2- or 3-pole CCP2  
switch and the right front/ right side rotary operated switches.  
A single unit monitors up to three phases. When used on 1- and  
2-pole switches unused conductor(s) are removed after installation.  
The CCP2-PLC-IND CANNOT be mounted on the left front/left side  
IP20 rating — yes  
rotary operated versions or if the multi-wire lug kit is installed.  
Storage and operating temperature  
Ratings  
•ꢀ  
-20°C to 75°C (-4°F to 167°F)  
•ꢀ  
Signal output to PLC*  
PLC programming  
•ꢀ +24 Vdc, 10 mA max  
•ꢀ  
The CCP2-PLC-IND signal line is designed to provide a digital  
•ꢀ  
Output signals  
input to a PLC I/O card. In this case, a Programmable Logic  
Control program must be written to properly interpret the input  
signal to the PLC. The PLC program should check for consecutive  
high signals before taking action on a critical process.  
•ꢀ Digital 0 Vdc (low), 24 Vdc max (high)  
•ꢀ 0 Vdc Low – fuse is good  
•ꢀ 24 Vdc High – fuse has opened  
Installed on a CCP2-3-xx  
* When the fuse opens, the output signal is sent high and will remain high until  
the unit is reset.  
Emissions and immunity testing  
•ꢀ  
IEC 60947-1: Voltage Switchgear and Control Gear  
•ꢀ  
IEC 61000-6-2: Electromagnetic Compatibility (EMC)  
•ꢀ IEC 61000-4-2: Electrostatic Discharge Immunity - Test at level  
3 (6 kV-Contact Discharge) and level 2 (4 kV-Air Discharge)  
•ꢀ IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radio-  
frequency, Electromagnetic Field Immunity test at level x  
(20 V/m)  
•ꢀ IEC 61000-4-4: Electromagnetic Compatibility - Testing and  
Measurement Techniques at level 3 (± 2 kV - Power Port and  
±1 kV - I/O Ports)  
CCP2-PLC-IND mounted on a 3-pole switch and using the fork  
terminals. When mounted on a 2- or 1-pole switch, remove unused  
leads.  
•ꢀ IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity  
test at level 4 (±4 kV)  
Note: The CCP2-PLC-IND CANNOT be mounted on the left front/left  
side rotary operated versions or if the multi-wire lug kit is installed.  
•ꢀ IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V)  
Max per  
CCP2**  
Signal output Min. circuit  
to PLC volts  
Description  
Wired remote fuse  
indication for PLC  
applications  
1 per CCP2  
(1, 2- or 3-pole)  
24 Vdc/ 10 mA 100 Vac  
**The CCP2-PLC-IND CANNOT be mounted on the left front/left side rotary  
operated versions or if the multi-wire lug kit is installed.  
De-energize all circuits and follow all prescribed safety procedures before installing  
or removing the CCP2-PLC-IND.  
Agency information  
•ꢀ  
UL 98 Recognized, Guide WHTY2, File E155130  
•ꢀ  
cURus to Canadian, Standard 22.2 No. 4-04  
Local indication  
•ꢀ  
Two distinct LEDs indicate unit power (green) and open fuse (red).  
Open fuse LED is resettable upon fuse replacement and actuating  
the reset switch.  
CCP2-PLC-IND fuse monitor mounted on a right front rotary  
operated switch.  
11-46  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
CCP2-PLC-IND connections from a CCP2-3-xx to a remote  
monitoring device  
PLC wiring schematic  
PLC power supply  
PLC fuse monitor  
Circuit monitoring leads from  
CCP2-PLC-IND to CCP2  
(100 – 600 Vac)  
+24 Vdc  
+24 Vdc  
0 Vdc/Gnd  
0 Vdc/Gnd  
Signal  
10 mA max.  
Circuit monitoring  
leads from PLC or  
remote monitoring  
device.  
The PLC fuse monitor needs  
to be powered by the same  
+24 Vdc and ground  
(0 Vdc/Gnd return)  
terminals that feed the  
PLC input card.  
If it is not, it may  
improperly signal.  
If feeding multiple  
+24 Vdc  
PLC fuse monitors from  
different power supplies,  
there must be multiple  
input cards being powered  
by those same power  
supplies as well.  
0 Vdc/Gnd  
PLC  
input card  
Connection from CCP2-PLC-IND to CCP2-3-xx  
Lead from CCP2-PLC-IND  
Power lead  
Leads from CCP2-PLC-IND are connected to the fork terminals as  
shown.  
Note: When monitoring a 1- or 2-pole switch, remove unused leads.  
Dimensions — in  
1.8  
Pin interlocks with  
CCP2 switch handle  
2.6  
1.9  
3.7  
0.3  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-47  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Class CC and UL Supplemental (IEC 10x38) clockwise rotary switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Right front rotary  
CCP2R-2-30CC  
CCP2R-3-30CC  
CCP2R-2-30M  
2
3
2
30  
CCP2R-3-30M  
3
Left front rotary  
CCP2RL-2-30CC  
CCP2RL-3-30CC  
CCP2RL-2-30M  
CCP2RL-3-30M  
Right side rotary  
CCP2S-2-30CC  
CCP2S-3-30CC  
CCP2S-2-30M  
2
3
2
3
30  
30  
2
3
2
3
CCP2S-3-30M  
And  
Rotary handles  
Description  
NEMA rating  
CCP2-H4X-B1  
Selector handle — black/grey  
Selector handle — red/yellow  
Pistol handle — black/grey  
Pistol handle — red/yellow  
CCP2-H4X-R1  
CCP2-H4X-B2  
CCP2-H4X-R2  
4X  
And  
Shafts (8 mm)  
CCP2-SH1-290  
CCP2-SH1-490  
Length  
290 mm  
490 mm  
NFPA 79 compliant  
handle  
Color  
CCP2-NFPA-1  
Red  
And  
Lug kits  
Description  
CCP2-MW1-3  
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
11-48  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
And  
Terminal shrouds  
Description  
CCP2-TS1-3  
Pack of 3  
Auxiliary contacts  
CCP2-AUX  
Description — cannot be used on right front or right side operated switches  
NO + NC, 5 A / 240 V  
PLC fuse monitor  
Description — Cannot be used on left front operated switches  
CCP2-PLC-IND  
Signal output 24 Vdc / 10 mA  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-49  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Class CC and UL Supplemental (IEC 10x38) Switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Switch  
CCP2-1-30CC  
CCP2-2-30CC  
CCP2-3-30CC  
CCP2-1-30M  
CCP2-2-30M  
CCP2-3-30M  
1
2
3
1
2
3
30  
And  
Lug kits  
Description  
CCP2-MW1-3  
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
And  
Terminal shrouds  
Description  
CCP2-TS1-3  
Pack of 3  
Auxiliary contacts  
CCP2-AUX  
Description  
NO + NC, 5 A / 240 V  
Description  
PLC fuse monitor  
CCP2-PLC-IND  
Signal output 24 Vdc / 10 mA  
11-50  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Class CC and UL Supplemental (IEC 10x38) counterclockwise switches  
For a complete assembly, select from the following required and optional components, and accessories.  
Catalog no.  
Switches  
Amps  
Poles  
Left side rotary  
CCP2SL-2-30CC  
CCP2SL-3-30CC  
CCP2SL-2-30M  
CCP2SL-2-30M  
2
3
2
2
30  
And  
Rotary handles  
Description  
NEMA rating  
CCP2-H4X-B1L  
Selector handle — black/grey  
Selector handle — red/yellow  
Pistol handle — black/grey  
Pistol handle — red/yellow  
CCP2-H4X-R1L  
CCP2-H4X-B2L  
CCP2-H4X-R2L  
4X  
And  
Shafts (8 mm)  
CCP2-SH1-290  
CCP2-SH1-490  
Length  
290 mm  
490 mm  
And  
Lug kits  
Description  
CCP2-MW1-3  
3-port multi-wire, 75°C Cu/Al, 6-14, includes terminal shrouds, pack of 3  
And  
Terminal shrouds  
CCP2-TS1-3  
Description  
Pack of 3  
Auxiliary contacts  
Description —mounts on right side  
CCP2-AUX  
NO + NC, 5 A / 240 V  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-51  
Eaton.com/bussmannseries  
11 — Disconnect switches  
CCPLP UL 98 Listed low profile Compact Circuit  
Protector  
Poles  
1-, 2- and 3-pole factory configured*  
2011/65/EU  
* 2- and 3-pole versions supplied as ganged switches with phase barriers.  
The revolutionary Bussmann  
series low profile Compact  
Agency information  
Circuit Protector (CCPLP) is a UL  
98/508 Listed fused disconnect  
switch. This front panel mount  
switch is available in 1-, 2- and  
3-pole versions, and has the  
smallest footprint of any fused  
disconnect switch. It features  
an SCCR up to 200 kA to help  
improve equipment SCCR.  
ꢀ  
Class G fuse versions  
UL 98 Listed, Guide WHTY, File E302370  
IEC 60947-3 AC-23A  
ꢀ  
Class CC fuse versions  
UL 98 Listed, Guide WHTY, File E302370  
cULus to Canadian Standard 22.2 No. 4-04, Guide WHTY7,  
File E302370  
Four fuse types  
IEC 60947-3 AC-23A  
The CCPLP is available for UL Class CC and G, UL supplemental  
(13/32” x 1-1/2”) and IEC 10x38 mm fuses.  
ꢀ  
UL supplemental and IEC 10x38mm fuse versions  
Class CC and G versions are easily selectively coordinated with  
the upstream Bussmann series CUBEFuse™ using published fuse  
ampacity ratio tables.  
UL 508 Listed, Guide NRNT, File E320230  
cULus Listed to Canadian Standard 22.2 No. 14-05, Guide  
NRNT7,  
File E320230  
Design/application flexibility  
IEC 60947-3 AC-23A  
The CCPLP is easily integrated into many panel designs and provides  
a high SCCR alternative to low profile circuit breakers on the market.  
ꢀ  
RoHS compliant  
ꢀ  
CE  
Ratings  
Safety  
ꢀ  
Volts  
ꢀ  
Finger-safe IP20 from panel front  
600 Vac (Class CC up to 30 A, Class G 20 A)  
550 Vac (10x38mm IEC Class aM 0.16-16 A)  
500 Vac (10x38mm IEC Class gG 0.5-25 A)  
400 Vac (10x38mm IEC Class aM 20-32 A, gG 32 A)  
240 Vac (13/32” x 1-1/2” UL supplemental 30 A)  
Mounting  
ꢀ  
Front panel mounting with customer supplied M3 screws  
Open fuse indication*  
ꢀ  
Amps  
ꢀ  
Local open fuse indication provided for each pole by an orange  
neon lamp (minimum 90 V)  
Up to 30 A (UL)  
Up to 32 A (IEC)  
* Open fuse indication requires an energized, closed circuit with an open fuse in  
the CCPLP and the switch in the ON position.  
ꢀ  
SCCR  
Lockout/tagout provision  
200 kA (Class CC)  
ꢀ  
120 kA (10x38mm IEC Class gG and aM)  
100 kA (Class G)  
Brady pin-out device, part number 90844  
Circuit labeling provision  
10 kA (13/32” x 1-1/2” UL supplemental)  
ꢀ  
Accepts up to two universal marker labels, catalog number  
TM26CB  
ꢀ  
Frequency 50/60 Hz  
ꢀ  
Impulse voltage 8 kV  
Carton quantity  
Terminals and conductors 75°C/90°C Cu  
ꢀ  
12 poles (1-pole: 12 units, 2-pole: 6 units, 3-pole: 4 units)  
ꢀ  
Screw terminal, 10-32 phil-slot screw with external tooth lock  
Minimum enclosure size  
washer (use with properly rated/UL Listed ring or fork terminal)  
ꢀ  
Pressure plate terminal, 10-32 phil-slot screw (single 22-6 AWG  
solid or stranded)  
ꢀ  
6” x 6” x 4” per UL 98 Listing  
Ambient storage and operating temperature  
ꢀ  
-20 to 90°C, 85% relative humidity, non-condensing  
Data sheet no.10372  
11-52  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Available CCPLP versions  
Catalog no.  
Horsepower (Vac)  
SCCR  
Screw terminal  
UL Class G fuse  
CCPLP-1-20G-S  
CCPLP-2-20G-S  
CCPLP-3-20G-S  
UL Class CC fuses  
CCPLP-1-30CC-S  
CCPLP-2-30CC-S  
CCPLP-3-30CC-S  
Pressure plate terminal  
Poles  
Volts AC  
Amps  
(kA)  
120  
240  
480  
600  
CCPLP-1-20G-P  
CCPLP-2-20G-P  
CCPLP-3-20G-P  
1
2
3
600  
20  
100  
CCPLP-1-30CC-P  
CCPLP-2-30CC-P  
CCPLP-3-30CC-P  
1
2
3
0.5  
2
3
4
7. 5  
600  
240  
30  
30  
200  
UL 13/32”x1-1/2” midget fuses  
CCPLP-1-30M-S  
CCPLP-1-30M-P  
1
2
3
CCPLP-2-30M-S  
CCPLP-2-30M-P  
CCPLP-3-30M-P  
10  
CCPLP-3-30M-S  
IEC 10x38 gG and aM fuses  
gG fuses:  
up to 25 A @ 500 V  
32 A @ 400 V  
CCPLP-1-30M-S  
CCPLP-1-30M-P  
1
120  
CCPLP-2-30M-S  
CCPLP-3-30M-S  
CCPLP-2-30M-P  
CCPLP-3-30M-P  
2
3
120  
120  
aM fuses:  
up to 16 A @ 550 A  
20-23 A @ 400V  
Switch handle (ganged on 2- and 3-pole versions)  
Fuse access door  
Open fuse indicating light  
Mounting holes for customer  
supplied M3 screws  
Lockout/tagout provision*  
Circuit marking area  
Phase barrier  
10/32 phil-slot screw or  
pressure plate terminal  
* Use Brady pin-out device, P/N 90844  
Available Bussmann series fuses  
Fuse class Catalog symbol  
CC  
G
FNQ-R, KTK-R, LP-CC  
SC  
M
BAF, FNM, FNQ, KLM, KTK  
gG  
aM  
C10G  
C10M  
Data sheet no.10372  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-53  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL 98 fused disconnect switches up to 800 A  
Bussmann series UL 98 and UL 489 fused disconnect switches  
“break” and “make” power circuits ON and OFF load.  
The switches employ double break contacts per pole that help  
ensure complete isolation of the fuse when the switch is in the  
"OFF" position.  
Agency information  
ꢀ  
UL 98, Guide WHTY, File E155130  
ꢀ  
UL 489, Guide WJAZ, File E359801  
ꢀ  
CSA 22.2 No. 4, File 257020  
ꢀ  
Conforms with IEC 60947-3  
ꢀ  
NFPA 79  
Features  
ꢀ  
Make and break power under load  
ꢀ  
Double break by pole  
ꢀ  
30-60 A DIN-Rail or panel mount, 100-800 A panel mount only  
ꢀ  
Up to 200 kA short-circuit current rating  
ꢀ  
Finger-safe covers  
ꢀ  
Compact footprints available  
ꢀ  
Defeatable handles automatically re-latch when the panel door is  
closed  
ꢀ  
Most disconnect switches are front, right side, flange or direct  
handle operable  
ꢀ  
NFPA 79 compliant handle kits  
Online resources available at Eaton.com/bussmannseries  
ꢀ  
CAD drawings  
ꢀ  
Instruction sheets  
ꢀ  
UL information  
Available Bussmann series fuses  
Fuse class Catalog symbol/type  
LP-CC time-delay, current limiting  
FNQ-R time-delay  
KTK-R fast-acting  
LPJ time-delay, current limiting  
JKS fast-acting fuses  
DFJ high speed drive fuse  
KRP-C time-delay, current limiting  
KTU fast-acting  
CC  
J
L
KLU time-delay  
KRP-CL (225-600 A)  
11-54  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 98 fused disconnect switches — 30 to 800 A  
RDF30CC-3  
RDF30J-3 / RDF60J-3-COMP  
RDF60J-3  
Catalog no.  
RDF200J-3  
RDF600J-3  
Poles  
2-pole  
RDF30J-3-  
COMP  
RDF30J-3N-  
COMP  
UL 489  
J
30  
RDF30J-2 RDF60J-2-COMP RDF60J-2 RDF100J-2 RDF200J-2  
RDF400J-2  
RDF400J-3  
RDF600J-2  
RDF600J-3  
RDF800L-2  
RDF800L-3  
3-pole  
RDF30CC-3  
RDF30J-3 RDF60J-3-COMP RDF60J-3 RDF100J-3 RDF200J-3  
3-pole + neutral  
RDF30CC-3N  
4-pole  
UL standard  
Fuse class  
Max fuse/ampacity  
Switch type  
UL 489  
CC  
30  
Compact  
RDF30J-4 RDF60J-4-COMP RDF60J-4 RDF100J-4 RDF200J-4  
RDF400J-4  
UL 98  
J
400  
Standard  
Front/Side ,  
Flange  
RDF600J-4  
UL 98  
J
600  
Standard  
RDF800L-4  
UL 98  
L
800  
Standard  
UL 98  
J
30  
UL 98  
J
60  
UL 98  
J
60  
UL 98  
J
100  
UL 98  
J
200  
Compact  
Standard  
Compact  
Standard  
Standard  
Front/Side , Front/Side ,  
Flange  
Standard  
Handle operation  
Front  
Front  
Front/Side  
Front/Side  
Front/Side  
Front , Flange Front , Flange  
Flange  
UL electrical ratings  
Max AC volts  
600 Vac  
600 Vac  
600 Vac  
250 Vdc  
3
3
5.0  
7. 5  
7. 5  
15  
20  
3
600 Vac  
250 Vdc  
10  
7. 5  
15  
15  
15  
30  
50  
5
600 Vac  
250 Vdc  
10  
7. 5  
15  
15  
15  
30  
50  
5
600 Vac  
250 Vdc  
10  
15  
25  
30  
30  
60  
75  
600 Vac  
10  
25  
50  
60  
60  
125  
150  
600 Vac  
250 Vdc  
10  
50  
100  
125  
125  
250  
350  
20  
600 Vac  
600 Vdc  
75  
150  
200  
200  
400  
500  
600 Vac  
600 Vdc  
Max DC volts*  
1-phase, 240  
3-phase, 240  
3-phase, 480  
3-phase, 600  
3-phase, 240  
3-phase, 480  
3-phase, 600  
125 Vdc  
3
3
75  
Std. AC Hp  
ratings  
5.0  
7. 5  
7. 5  
15  
20  
5.0  
7. 5  
7. 5  
15  
20  
200  
250  
200  
500  
500  
Max. AC Hp  
ratings  
7. 5  
20  
DC Hp ratings  
250 Vdc  
5
10  
10  
50  
Electrical characteristics  
SCCR  
Terminal lugs/kits  
Mounting torque - lb-in (N•m)  
Wire type  
100 kA  
Integral  
75°C Cu  
14-10, 27  
(3.1)  
100 kA  
Integral  
75°C Cu  
14-10, 27  
(3.1)  
200 kA  
Integral  
75°C Cu  
14-10, 31  
(3.5)  
100 kA  
Integral  
200 kA  
Integral  
200 kA  
Integral  
200 kA  
160 (18)  
75°C Cu/ Al  
200 kA  
310 (35)  
75°C Cu/ Al  
200 kA  
310 (35)  
75°C Cu/ Al  
200 kA  
310 (35)  
75°C Cu/ Al  
75°C Cu  
75°C Cu  
75°C Cu  
12-10, 35.4 12-10, 35.4  
Solid  
Wire range,  
14-10, 31 (3.5)  
14-6, 31 (3.5)  
(4)  
(4)  
4-600 kcmil,  
550 (62),  
Dual 1/0-250  
kcmil 550 (62)  
torque - lb-in  
(N•m)  
(2) 2-600  
kcmil, 375  
(42.4)  
(2) 2-600  
kcmil, 375  
(42.4)  
14-6 , 31  
(3.5)  
6-300 kcmil,  
275 (31)  
14-10 27  
(3.1)  
12-1, 35.4  
(4)  
Stranded  
14-10 27 (3.1)  
10,000  
12-1, 35.4 (4)  
Mechanical characteristics  
Endurances/cycles  
Physical characteristics  
Dimensions  
10,000  
10,000  
10,000  
10,000  
10,000  
8000  
6000  
5000  
5000  
See drawings on product pages  
2-pole  
1.3 (0.6)  
1.4 (0.6)  
3.0 (1.3)  
3.8 (1.7)  
3.1 (1.4)  
4.1 (1.8)  
4.1 (1.8)  
5.3 (2.4)  
4.1 (1.8)  
5.3 (2.4)  
5.7 (2.6)  
7.8 (3.5)  
11.4 (5.2)  
16.6 (7.6)  
31.7 (14.4)  
44.2 (20.1) 44.2 (20.1)  
31.7 (14.4)  
3-pole  
Weight - lbs  
3-pole +  
(kg)  
1.4 (0.6)  
1.5 (0.7)  
neutral  
4-pole  
Environmental  
Operating temp. range  
Flammability rating  
Accessories  
4.7 (2.1)  
4.8 (2.2)  
6.49 (2.9)  
6.49 (2.9)  
10.8 (4.9)  
21.8 (9.9)  
56.8 (25.8) 56.8 (25.8)  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
-20-70°C  
UL 94-V0  
Lug Kit  
Integral  
Integral  
Integral  
Integral  
Integral  
Integral  
Direct  
Front  
selector  
Front pistol  
Side pistol  
Cable  
Handles  
Flange  
Shaft  
NFPA through door handle  
Shafts c/s - mm  
5x5  
Not  
Required  
5x5  
Not  
Required  
10x10  
Not  
Required  
10x10  
Not  
Required  
10x10  
Not  
Required  
10x10  
10x10  
10x10  
12X12  
12X12  
Terminal shrouds  
Not Required  
(1) NO  
(1) NC  
Volts  
600  
10  
600  
10  
600  
10  
600  
10  
600  
10  
Auxiliary  
contacts  
600  
10  
600  
10  
600  
10  
600  
10  
600  
10  
AC ratings  
Amps  
• Available, see product page for details and catalog numbers.  
Not available.  
* General purpose only, not photovoltaic rated.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-55  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL 98 fused rotary disconnect switches — 30 A  
Standard 30 amp Class CC and compact 30 amp Class J  
For a complete assembly, select:  
Switch  
Max Hp rating, 3-phase  
220/240 440/480 600 AWG size /type  
Fuse  
class  
SCCR  
(kA)  
100  
100  
100  
Conductor  
Amps  
30  
30  
30  
30  
Poles  
3
3 + Ntrl.*  
3
3 + Ntrl.*  
Catalog no.  
RDF30CC-3  
RDF30CC-3N  
RDF30J-3-COMP  
RDF30J-3N-COMP  
7. 5  
7. 5  
7. 5  
7. 5  
15  
15  
15  
15  
20  
20  
20  
20  
CC  
14-10 Sol/Str  
75°C Cu  
J
100  
* Neutral is switched.  
Plus  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
Color  
Test function  
Padlockable  
Catalog no.  
DIR-05  
RDF30CC-_  
Black  
Y
Y
RDF30J-_-COMP  
DIR-06  
OR  
External front operated selector handle - shaft required  
NEMA type  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Defeatable  
Catalog no.  
H4X-04B  
H4X-04R  
N
Y
Y
+
Shafts for selector handles  
Length - in (mm)  
7.9 (200)  
12.6 (320)  
Mounting depth (X) - in (mm)  
4.02~9.65 (102~245)  
4.02~14.37 (102~365)  
4.02~17.52 (102~445)  
Catalog no.  
SH1-200  
SH1-320  
SH1-400  
15.7 (400)  
OR  
External front operated pistol handles - shaft required  
NEMA type  
1, 3R, 12  
1, 3R, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Black  
Red/yellow  
Black  
Red/yellow  
Test function  
Padlockable  
Defeatable  
Y
Catalog no.  
H12-05B  
H12-05R  
H4X-05B  
H4X-05R  
H4X-05TB  
H4X-05TR  
N
Y
Y
or  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA type  
Color  
Test function  
Padlockable  
Defeatable  
Catalog no.  
H4X-05BHD  
1, 3R, 4, 4X, 12  
Black  
N
Y
Y
1, 3R, 4, 4X, 12  
Red/yellow  
H4X-05RHD  
+
Shafts for pistol handles  
Length - in (mm)  
7.9 (200)  
12.6 (320)  
Mounting depth (X) - in (mm)  
4.02~9.65 (102~245)  
4.02~14.37 (102~365)  
4.02~17.52 (102~445)  
Catalog no.  
SH2-200  
SH2-320  
SH2-400  
15.7 (400)  
OR  
NFPA through the door handle kit - to be used with front pistol handle  
Color  
Test function  
Padlockable  
Defeatable  
N
Catalog no.  
H79-1  
Red  
N
Y
AND...  
Auxiliary contacts  
Contact  
type  
NO  
No. of Continuous  
contacts amp rating  
Maximum number of auxiliary contacts per  
disconnect switch catalog number  
RDF30CC-_: 4 / 8 with BAC-HOLDER2  
BAC05 (1) RDF30J-_-COMP: 2 /6 with BAC-  
HOLDER2  
Voltage (Vac)  
600  
Catalog no.  
BAC05 (1)  
1
10  
NC  
BAC06 (1)  
Accepts 4 Auxiliary contacts: BAC05 or  
BAC06  
Auxiliary contact holder  
BAC-HOLDER2 (2)  
1
2
11-56  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Dimensions — in (mm)  
RDF30CC-_  
3.28  
83.3  
3.78  
96  
1.12  
28.5  
1.47 0.59  
37.5 15  
5.19 (131.8)  
Fuse Cover Fully Open  
RDF30J-_-COMP  
4.13  
105  
3.89  
99  
1.47  
37.5  
0.59  
15  
1.12  
28.5  
External front selector handle  
Selector handle type  
Direction of front operation  
Door drilling layout  
1.57  
40  
I
0.11  
3
4 Ø 0.27  
4 Ø 7  
Ø3.07  
Ø78  
0
1.45  
37  
Ø 1.22  
Ø 31  
Ø
Ø
0.88  
22.5  
H4X-04_  
With mounting nut  
With 4 Mounting Screws  
External front pistol handles  
Pistol handle type  
Direction of front operation  
I
Door drilling layout  
Ø 1.46  
Ø 37  
4 Ø 0.27  
Ø3.07  
Ø78  
4 Ø 7  
0
H4X-05__  
H12-05__  
1.73  
44  
0.55  
14  
0.55  
14  
TEST  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-57  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Standard 30 amp Class J  
For a complete assembly, select:  
Switch  
Max horsepower rating  
3-phase  
220/240 220/240 440/480 600  
1-phase  
DC*  
125  
3
3
3
Fuse  
class  
SCCR  
(kA)  
Conductors  
Amps  
30  
Poles  
250 AWG size / type  
5
Catalog no.  
RDF30J-2  
RDF30J-3  
RDF30J-4  
2
3
4
3
-
-
-
-
-
14-10 Sol/14-6 Str  
J
200  
7. 5  
7. 5  
15  
15  
20  
20  
5
5
75°C Cu  
* DC ratings use two poles in series.  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
Color  
Test function  
Padlockable  
Catalog no.  
DIR-07  
All switches  
Black  
Y
OR  
Y - On switch  
External front operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Black  
Red/yellow  
Black  
Red/yellow  
Test function  
Padlockable  
Y
Defeatable  
Y
Catalog no.  
H12-05B  
H12-05R  
H4X-05B  
H4X-05R  
H4X-05TB  
H4X-05TR  
1, 3R, 12  
N
Y
1, 3R, 4, 4X, 12  
Or  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA  
Color  
Color  
Test function  
N
Padlockable  
Y
Defeatable  
Y
Catalog no.  
type  
Black  
Red/yellow  
H4X-05BHD  
H4X-05RHD  
1, 3R, 4, 4X, 12  
External right side operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Y
Defeatable  
N/A  
Catalog no.  
H4X-05SB  
H4X-05SR  
1, 3R, 4, 4X, 12  
N
+
Shafts for pistol handles  
Length — in (mm) Mounting depth (X) — in (mm)  
Catalog no.  
SH5-200  
SH5-320  
SH5-400  
7.9 (200)  
5.30~9.06 (135~230)  
5.30~13.78 (135~350)  
5.30~16.93 (135~430)  
12.6 (320)  
15.7 (400)  
OR  
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable  
1
2
NEMA type  
1, 3R, 4, 12  
Flange style  
Standard  
Test function  
Padlockable  
Defeatable  
Catalog no.  
FLH1  
FLH2  
N
Y
Y
1, 3R, 4, 4X, 12  
Chrome plated  
Shaft operated flange mechanism (2) - includes shaft  
For enclosure depth - in (mm)  
6~24 (152~613)  
Catalog no.  
FLRM  
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)  
Item / length — in (mm)  
Cable mechanism  
Catalog no.  
FLCM  
4
36 (900) cable  
FLC36  
60 (1500) cable  
FLC60  
120 (3000) cable  
FLC120  
OR  
NFPA through the door handle kit - to be used with front pistol handle  
Color  
Test function  
Padlockable  
Y
Defeatable  
N
Catalog no.  
H79-2  
Red  
N
AND...  
Auxiliary contacts  
Contact  
No. of contacts  
Continuous amp rating  
10  
Voltage (Vac)  
600  
Max. aux contacts per switch  
Catalog no.  
BAC05  
type  
NO  
1
4
NC  
BAC06  
11-58  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Dimensions — in (mm)  
5.87  
149.3  
4.84  
123  
1.41  
36  
1.46  
37.2  
1.41  
36  
Direct mount handle  
1.57  
40  
1.79  
45.5  
DIR-07  
Flange handle  
3.50  
(88.9)  
2.16  
Ø0.28  
7.1)  
(54.9)  
Ø0.50  
(Ø12.7)  
1.55  
1.06  
(39.4)  
0.86  
(26.9)  
(21.8)  
4.68  
(118.9)  
5.66  
(143.8)  
1.00  
(25.4)  
6.22  
(158.0)  
1.00 0.88  
(25.4) (22.3)  
2.32  
2.70  
(68.6)  
(58.9)  
7. 10  
(180.3)  
FLH_  
External front and right side pistol handle  
Handle type  
Direction of front operation Direction of right side operation Door drilling layout  
I
I
Ø 1.46  
Ø 37  
Ø3.07  
Ø78  
4 Ø 0.27  
4 Ø 7  
0
0
H4X-05__  
H12-05__  
1.73  
44  
0.55  
14  
TEST  
0.55  
14  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-59  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Compact 60 amp Class J  
For a complete assembly, select:  
Switch  
Max horsepower rating  
3-phase  
220/240 220/240 440/480 600  
1-phase  
DC*  
Fuse  
SCCR  
(kA)  
Conductor  
Amps  
60  
class Poles  
125  
5
5
250 AWG size / type  
10  
10  
Catalog no.  
2
3
4
10  
-
-
-
-
-
RDF60J-2-COMP  
RDF60J-3-COMP  
RDF60J-4-COMP  
14-10 Sol/14-6 Str  
75°C Cu  
J
100  
15  
15  
30  
30  
50  
50  
5
10  
* DC ratings use two poles in series.  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
Color  
Test function  
Padlockable  
Catalog no.  
DIR-07  
All switches  
Black  
Y
Y - on switch  
OR  
External front operated pistol handles - shaft required  
NEMA type  
1, 3R, 12  
1, 3R, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Black  
Red/yellow  
Black  
Red/yellow  
Test function  
N
Padlockable  
Y
Defeatable  
Y
Catalog no.  
H12-05B  
H12-05R  
H4X-05B  
H4X-05R  
H4X-05TB  
H4X-05TR  
Y
Or  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA type  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Defeatable  
Y
Catalog no.  
H4X-05BHD  
H4X-05RHD  
N
Y
External right side operated pistol handles - shaft required  
NEMA type  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Y
Defeatable  
N/A  
Catalog no.  
H4X-05SB  
H4X-05SR  
N
+
Shafts for pistol handles  
Length — in (mm) Mounting depth (X) - in (mm)  
Catalog no.  
SH5-200  
SH5-320  
SH5-400  
7.9 (200)  
5.30~9.06 (135~230)  
5.30~13.78 (135~350)  
5.30~16.93 (135~430)  
12.6 (320)  
15.7 (400)  
OR  
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable  
1
2
NEMA type  
1, 3R, 4, 12  
Flange style  
Standard  
Test function  
Padlockable  
Defeatable  
Catalog no.  
FLH1  
FLH2  
N
Y
Y
1, 3R, 4, 4X, 12  
Chrome plated  
Shaft operated flange mechanism (2) - includes shaft  
For enclosure depth - in (mm)  
6~24 (152~613)  
Catalog no.  
FLRM  
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)  
Item / length — in (mm)  
Cable mechanism  
Catalog no.  
FLCM  
4
36 (900) cable  
FLC36  
60 (1500) cable  
FLC60  
120 (3000) cable  
FLC120  
OR  
NFPA through the door handle kit - to be used with selector handle or front pistol handle  
Color  
Test function  
Padlockable  
Defeatable  
N
Catalog no.  
H79-2  
Red  
N
Y
AND...  
Auxiliary contacts  
Continuous amp  
rating  
Contact type  
No. of contacts  
1
Voltage (Vac)  
600  
Max. aux contacts per switch  
4
Catalog no.  
BAC05  
NO  
NC  
10  
BAC06  
11-60  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Dimensions — in (mm)  
4.13  
105  
3.89  
99  
1.47  
37.5  
0.59  
15  
1.12  
28.5  
Direct mount handle  
1.57  
40  
1.79  
45.5  
DIR-07  
Flange handle  
3.50  
(88.9)  
Ø0.28  
7.1)  
2.16  
(54.9)  
Ø0.50  
(Ø12.7)  
1.55  
1.06  
(39.4)  
0.86  
(26.9)  
(21.8)  
4.68  
5.66  
(143.8)  
(118.9)  
1.00  
(25.4)  
6.22  
(158.0)  
1.00 0.88  
(25.4) (22.3)  
2.32  
2.70  
(68.6)  
(58.9)  
7. 10  
(180.3)  
FLH_  
External front and right side pistol handle  
Handle type  
Direction of front operation Direction of right side operation Door drilling layout  
I
I
Ø 1.46  
Ø 37  
Ø3.07  
Ø78  
4 Ø 0.27  
4 Ø 7  
0
0
H4X-05__  
H12-05__  
1.73  
44  
0.55  
14  
TEST  
0.55  
14  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-61  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Standard 60 amp Class J  
For a complete assembly, select:  
Switch  
Max horsepower rating  
3-phase  
220/240 220/240 440/480 600  
1-phase  
DC*  
250 size/type  
Fuse  
SCCR  
(kA)  
200  
200  
200  
Conductor AWG  
Amps  
60  
class Poles  
125  
5
5
Catalog no.  
RDF60J-2  
RDF60J-3  
RDF60J-4  
2
3
4
10  
-
-
-
-
-
10  
10  
10  
12-10 Sol/12-1 Str  
75°C Cu  
J
15  
15  
30  
30  
50  
50  
5
* DC ratings use two poles in series.  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
Color  
Test function  
Padlockable  
Y
Catalog no.  
DIR-07  
All switches  
Black  
Y
OR  
External front operated pistol handles - shaft required  
NEMA type  
1, 3R, 12  
1, 3R, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Black  
Red/yellow  
Black  
Red/yellow  
Test function  
Padlockable  
Y
Defeatable  
Y
Catalog no.  
H12-03B  
H12-03R  
H4X-06B  
H4X-06R  
H4X-06TB  
H4X-06TR  
N
Y
Or  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA type  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Defeatable  
Y
Catalog no.  
H4X-06BHD  
H4X-06RHD  
N
Y
External right side operated pistol handles - shaft required  
NEMA type  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Y
Defeatable  
N/A  
Catalog no.  
H4X-06SB  
H4X-06SR  
N
+
Shafts for pistol handles  
Length — in (mm) Mounting depth (X) — in (mm)  
Catalog no.  
SH5-200  
SH5-320  
SH5-400  
7.9 (200)  
5.30~9.06 (135~230)  
5.30~13.78 (135~350)  
5.30~16.93 (135~430)  
12.6 (320)  
15.7 (400)  
OR  
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable  
1
2
NEMA type  
1, 3R, 4, 12  
Flange style  
Standard  
Test Function  
Padlockable  
Defeatable  
Catalog no.  
FLH1  
FLH2  
N
Y
Y
1, 3R, 4, 4X, 12  
Chrome plated  
Shaft operated flange mechanism (2) - includes shaft  
For enclosure depth — in (mm)  
6~24 (152~613)  
Catalog no.  
FLRM  
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)  
Item / length — in (mm)  
Cable mechanism  
Catalog no.  
FLCM  
4
36 (900) cable  
FLC36  
60 (1500) cable  
FLC60  
120 (3000) cable  
FLC120  
OR  
NFPA through the door handle kit - to be used with front pistol handle  
Color  
Test function  
Padlockable  
Y
Defeatable  
N
Catalog no.  
H79-2  
Red  
N
AND...  
Auxiliary contacts  
Continuous amp  
rating  
Max number of aux contacts per  
switch  
Contact type  
No. of contacts  
1
Voltage (Vac)  
600  
Catalog no.  
BAC05  
NO  
NC  
10  
4
BAC06  
11-62  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Dimensions — in (mm)  
5.87  
4.81  
149.3  
122.2  
1.41  
36  
1.46  
37.2  
1.41  
36  
Direct mount handle  
1.57  
40  
1.79  
45.5  
DIR-07  
Flange handle  
3.50  
(88.9)  
Ø0.28  
7.1)  
2.16  
(54.9)  
Ø0.50  
(Ø12.7)  
1.55  
1.06  
(39.4)  
0.86  
(26.9)  
(21.8)  
4.68  
(118.9)  
5.66  
(143.8)  
1.00  
(25.4)  
6.22  
(158.0)  
1.00 0.88  
(25.4) (22.3)  
2.32  
2.70  
(68.6)  
(58.9)  
7. 10  
(180.3)  
FLH_  
External front and right side pistol handle  
Handle type  
Direction of front operation Direction of right side operation  
Door drilling layout  
Ø 1.46  
I
I
Ø3.07  
Ø78  
Ø 37  
4 Ø 0.27  
4 Ø 7  
0
H4X-06__  
H12-03__  
1.77  
45  
TEST  
0.55  
14  
0.55  
14  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-63  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Standard 100 amp Class J  
For a complete assembly, select:  
Switch  
Max horsepower rating  
3-phase  
220/240 220/240 440/480 600 125 250 AWG size/type  
1-phase  
DC*  
Fuse  
class Poles  
SCCR  
(kA)  
Conductor  
Amps  
100  
Catalog no.  
RDF100J-2  
RDF100J-3  
RDF100J-4  
2
3
4
10  
-
-
-
30  
30  
-
60  
60  
-
75  
75  
7. 5  
7. 5  
7. 5  
20  
20  
20  
12-10 Sol/12-1 Str  
75°C Cu  
J
200  
* DC ratings use two poles in series.  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat.  
Color  
Test function Padlockable  
Catalog no.  
DIR-07  
no.  
All switches  
Black  
Y
Y
OR  
External front operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Black  
Red/yellow  
Black  
Red/yellow  
Test function Padlockable  
Defeatable  
Y
Catalog no.  
H12-03B  
H12-03R  
H4X-06B  
H4X-06R  
H4X-06TB  
H4X-06TR  
1, 3R, 12  
N
Y
1, 3R, 4, 4X, 12  
Y
Or  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA type  
1, 3R, 4, 4X, 12  
1, 3R, 4, 4X, 12  
Color  
Black  
Red/yellow  
Test function Padlockable  
Defeatable  
Y
Catalog no.  
H4X-06BHD  
H4X-06RHD  
N
Y
External right side operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Test function Padlockable  
Defeatable  
N/A  
Catalog no.  
H4X-06SB  
H4X-06SR  
1, 3R, 4, 4X, 12  
N
Y
+
Shafts for pistol handles  
Length — in  
(mm)  
Mounting depth (X) - in (mm)  
Catalog no.  
7.9 (200)  
12.6 (320)  
15.7 (400)  
5.30~9.06 (135~230)  
5.30~13.78 (135~350)  
5.30~16.93 (135~430)  
SH5-200  
SH5-320  
SH5-400  
OR  
Flange handle (1) - requires shaft operated mechanism or cable operated mechanism + cable  
1
2
NEMA type  
1, 3R, 4, 12  
Flange style  
Standard  
Test function Padlockable  
Defeatable  
Catalog no.  
FLH1  
FLH2  
N
Y
Y
1, 3R, 4, 4X, 12  
Chrome plated  
Shaft operated flange mechanism (2) - includes shaft  
For enclosure depth — in (mm)  
6~24 (152~613)  
Catalog no.  
FLRM  
3
Cable operated flange mechanism and cable - must select mechanism (3) and cable (4)  
Item / length — in (mm)  
Cable mechanism  
Catalog no.  
FLCM  
4
36 (900) cable  
FLC36  
60 (1500) cable  
FLC60  
120 (3000) cable  
FLC120  
OR  
NFPA through the door handle kit - to be used with front pistol handle  
Color  
Test function Padlockable  
Defeatable  
N
Catalog no.  
H79-2  
Red  
N
Y
AND...  
Auxiliary contacts  
Continuous amp  
rating  
Max number of aux contacts  
per switch  
Contact type  
No. of contacts  
1
Voltage (Vac)  
600  
Catalog no.  
BAC05  
NO  
NC  
10  
4
BAC06  
11-64  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Dimensions — in (mm)  
5.87  
149.3  
4.81  
122.2  
1.41  
36  
1.46  
37.2  
1.41  
36  
Direct mount handle  
1.57  
40  
1.79  
45.5  
DIR-07  
Flange handle  
3.50  
(88.9)  
Ø0.28  
7.1)  
2.16  
(54.9)  
Ø0.50  
(Ø12.7)  
1.55  
1.06  
(39.4)  
0.86  
(26.9)  
(21.8)  
4.68  
(118.9)  
5.66  
(143.8)  
1.00  
(25.4)  
6.22  
(158.0)  
1.00 0.88  
(25.4) (22.3)  
2.32  
2.70  
(68.6)  
(58.9)  
7. 10  
(180.3)  
FLH_  
External front and right side pistol handle  
Handle type  
Direction of front operation Direction of right side operation  
Door drilling layout  
Ø 1.46  
I
I
Ø3.07  
Ø78  
Ø 37  
4 Ø 0.27  
4 Ø 7  
0
H4X-06__  
H12-03__  
1.77  
45  
TEST  
0.55  
14  
0.55  
14  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-65  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Standard 200 and 400 amp Class J  
For a complete assembly, select:  
Switch  
Max horsepower rating  
3-phase  
220/240 220/240 440/480 600  
1-phase  
DC*  
Fuse  
class  
SCCR  
(kA)  
Amps  
200  
Poles  
125  
-
-
250  
-
-
Catalog no.  
RDF200J-2  
RDF200J-3  
RDF200J-4  
RDF400J-2  
RDF400J-3  
RDF400J-4  
2
3
4
2
3
4
10  
-
-
10  
-
-
-
-
-
60  
60  
-
125  
125  
-
150  
150  
-
-
-
J
200  
20  
20  
20  
50  
50  
50  
400  
125  
125  
250  
250  
350  
350  
* DC ratings use two poles in series.  
+
Terminal lug kit  
Switch amps  
Poles  
Lugs per kit  
AWG wire / type  
Catalog no.  
LUG1-2  
LUG1-3  
LUG1-4  
LUG2-2  
LUG2-3  
LUG2-4  
2
3
4
2
3
4
2
3
4
2
3
4
6-300 kcmil  
75°C Cu/Al  
200  
4-600 kcmil or dual 1/0-250 kcmil  
75°C Cu/Al  
400  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
Color  
Test function  
Padlockable  
Catalog no.  
DIR-07  
All switches  
Black  
Y
Y
OR  
External front operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Black  
Red/yellow  
Black  
Red/yellow  
Test function  
Padlockable  
Defeatable  
Y
Catalog no.  
H12-03B  
H12-03R  
H4X-06B  
H4X-06R  
H4X-06TB  
H4X-06TR  
1, 3R, 12  
N
Y
1, 3R, 4, 4X, 12  
Y
Or  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Defeatable  
Catalog no.  
H4X-06BHD  
H4X-06RHD  
1, 3R, 4, 4X, 12  
N
Y
Y
External right side operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Test function  
Padlockable  
Defeatable  
N/A  
Catalog no.  
H4X-06SB  
H4X-06SR  
1, 3R, 4, 4X, 12  
N
Y
+
Shafts for pistol handles  
Length — in (mm) Mounting depth (X) — in (mm)  
Catalog no.  
SH5-200  
200 A: 5.70-9.06 (145-230)  
7.9 (200)  
400 A: 7.87-10.24 (200-260)  
200 A: 5.70-13.78 (145-350)  
12.6 (320)  
SH5-320  
SH5-400  
400 A: 7.87-16.93 (200-380)  
200 A: 5.70-16.93 (145-430)  
15.7 (400)  
400 A: 7.87-18.10 (200-460)  
OR  
Flange handle (1) 200 A only - requires shaft operated mechanism or cable operated mechanism +  
cable  
1
2
NEMA type  
1, 3R, 4, 12  
Flange style  
Standard  
Test function  
Padlockable  
Defeatable  
Catalog no.  
FLH1  
N
Y
Y
1, 3R, 4, 4X, 12  
Chrome plated  
FLH2  
Shaft operated flange mechanism (2) 200 A only - includes shaft  
For enclosure depth — in (mm)  
6~24 (152~613)  
Catalog no.  
FLRM  
3
Cable operated flange mechanism and cable 200 A only - must select Mechanism (3) and Cable (4)  
Item — in (mm)  
Cable mechanism  
36 (900) cable  
Catalog no.  
FLCM  
FLC36  
4
60 (1500) cable  
120 (3000) cable  
FLC60  
FLC120  
11-66  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
OR  
NFPA through the door handle kit - to be used with front pistol handle  
Use with switch  
RDF200J-_  
Color  
Red  
Test function  
N
Padlockable  
Y
Defeatable  
N
Catalog no.  
H79-2  
RDF400J-_  
H79-3  
AND...  
Auxiliary contacts  
Max number of  
aux contacts per  
switch catalog  
number  
RDF200J-__: 4  
RDF400J-__: 8  
Continuous amp  
rating  
Contact type  
No. of contacts  
1
Voltage (Vac)  
600  
Catalog no.  
NO  
NC  
BAC05  
BAC06  
10  
AND...  
Terminal shrouds - includes terminal shroud for lineside or loadside  
Switch amps  
Poles  
2
3
Catalog no.  
TSH8-2TB  
TSH8-3TB  
200  
4
TSH8-4TB  
2
3
TSH9-2TB  
TSH9-3TB  
400  
4
TSH9-4TB  
Dimensions — in (mm)  
RDF200J-3  
RDF400J-3  
7.72  
196.2  
7.08  
180  
6.61  
168  
4.37  
111.1  
10.19 (3P) - 12.79 (4P)  
259 (3P) - 325 (4P)  
6.18  
157  
0.98  
24.9  
1.41  
36  
3.26  
83  
1.96  
50  
5.11  
130  
2.59  
66  
2.59  
66  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-67  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Dimensions — in (mm)  
DIR-07 direct mount handle  
FLH_ flange handle  
3.50  
(88.9)  
1.57  
40  
1.79  
45.5  
Ø0.28  
7.1)  
2.16  
(54.9)  
Ø0.50  
(Ø12.7)  
1.55  
1.06  
(39.4)  
0.86  
(26.9)  
(21.8)  
4.68  
5.66  
(143.8)  
(118.9)  
1.00  
(25.4)  
6.22  
(158.0)  
1.00 0.88  
(25.4) (22.3)  
2.32  
2.70  
(68.6)  
(58.9)  
7. 10  
(180.3)  
External front and right side pistol handle  
Handle type  
Direction of front operation Direction of right side operation  
Door drilling layout  
Ø 1.46  
I
I
Ø3.07  
Ø78  
Ø 37  
4 Ø 0.27  
4 Ø 7  
0
H4X-06__  
H12-03__  
1.77  
45  
TEST  
0.55  
14  
0.55  
14  
Terminal lugs  
200 A (LUG1-__)  
400 A (LUG2-__)  
Ø 0.4  
Ø 4.7  
0.45  
Ø11.6  
2.8  
0.63  
71.5  
15.88  
1.52  
38.8  
0.46  
11.68  
11-68  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Standard 600 amp Class J and 800 amp Class L  
For a complete assembly, select:  
Switch  
Max horsepower rating, 3-phase  
Fuse  
Amps  
600  
class  
Poles  
SCCR ()kA)  
200  
220/240  
440/480  
600  
-
Catalog no.  
RDF600J-2  
RDF600J-3  
RDF600J-4  
RDF800L-2  
RDF800L-3  
RDF800L-4  
2
3
4
2
3
4
-
-
J
200  
200  
-
400  
400  
-
500  
500  
-
800  
L
200  
200  
500  
500  
500  
500  
+
Terminal lug kit  
Switch amps  
Poles  
2
Lugs per kit  
2
Conductor AWG size / type  
Catalog no.  
LUG5-2  
(2) 2-600 kcmil  
75°C Cu/ Al  
600-800  
3
4
3
4
LUG5-3  
LUG5-4  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
Test  
For switch cat. no.  
All switches  
Color  
Black  
Padlockable  
Y
Defeatable  
N
Catalog no.  
DIR-08  
function  
Y
OR  
External front operated pistol handles - shaft required  
Test  
NEMA type  
Color  
Padlockable  
Y
Defeatable  
Y
Catalog no.  
function  
Black  
Red/yellow  
H4X-07B  
H4X-07R  
1, 3R, 4, 4X, 12  
N
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA  
type  
Test  
Or  
Color  
Padlockable  
Y
Defeatable  
Y
Catalog no.  
H4X-07BHD  
function  
Black  
1, 3R, 4, 4X, 12  
N
Red/yellow  
H4X-07RHD  
Shafts for pistol handles  
+
Length — in (mm) Mounting depth (X) — in (mm)  
Catalog no.  
SH7-200  
7.9 (200)  
10.63~11.97 (270~304)  
10.63~16.69 (270~424)  
10.63~19.84 (270~504)  
12.6 (320)  
15.7 (400)  
SH7-320  
SH7-400  
OR  
NFPA through the door handle kit - to be used with front pistol handle  
Test func-  
For switch cat. no.  
All switches  
Color  
Padlockable  
Y
Defeatable  
N
Catalog no.  
H79-4  
tion  
Red  
N
AND...  
Auxiliary contacts  
No. of  
Continuous  
Voltage  
(Vac)  
Max number of aux contacts per  
switch  
Contact type  
Catalog no.  
contacts amp rating  
NO  
NC  
BAC05  
BAC06  
1
10  
600  
8
AND...  
Terminal shrouds - includes terminal shroud for lineside or loadside  
Switch amps  
Poles  
Catalog no.  
TSH10-2TB  
2
600-800  
3
4
TSH10-3TB  
TSH10-4TB  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-69  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Dimensions — in (mm)  
RDF600J-3 and RDF800L-3  
min 10.43  
min 265  
11.18 (3P) - 14.88 (4P)  
284 (3P) - 378 (4P)  
9.84  
250  
6.10  
155  
1.34  
34  
2.56  
65  
3.12  
79.5  
0.43  
11  
0.27  
7
Ø 0.51  
Ø13  
0.35  
9
2.32  
59  
2
51  
3.7  
94  
3.7  
94  
14.96  
380  
18.58  
472  
14.33 (3P) - 18.03 (4P)  
364 (3P) - 458 (4P)  
Fuse Cover Fully Open  
Dir-08 drect mount handle  
2.36  
60  
3.35  
85  
External front pistol handle  
Direction of front operation  
I
Door drilling layout  
Handle type  
Ø3.07  
Ø78  
Ø 1.46  
Ø 37  
4 Ø 0.27  
4 Ø 7  
0.55  
14  
0.55  
14  
H4X-07__  
61  
Terminal lugs  
600 to 800 A (LUG5-__)  
3.76  
95.5  
0.40  
Ø10.2  
3.15  
80  
11-70  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 98 non-fused rotary disconnect switches — 30  
to 1200 amps  
Bussmann series UL 98 non-fused rotary disconnect switches are  
versatile switches that “break” and “make” power circuits ON and  
OFF load.  
Agency information  
ꢀ  
UL 98, Guide WHTY, File E155130  
ꢀ  
CSA 22.2 No. 4, File 257020  
ꢀ  
Conforms with IEC 60947-3  
Features  
Related Bussmann series products  
ꢀ  
Make and break power under load  
ꢀ  
ꢀ  
ꢀ  
Fuse blocks  
Up to 200 kA SCCR  
Modular Class H(K), J and RK fuse blocks up to 600 A  
Modular Class H(K), J and RK power distribution fuse blocks up to 400 A  
Modular, finger-safe CH Class CC and J, and UL supplemental and IEC  
10x38mm DIN-Rail holders up to 60 A  
Panel mount (30-100 A compact DIN-Rail or panel mount)  
Disconnect switches are front, right side and direct handle  
operable (30-100 A)  
ꢀ  
ꢀ  
Finger-safe (30-100 A compact only)  
Fully visualized breaking (100-1200 A)  
Finger-safe Optima Class CC, UL supplemental and IEC 10x38mm DIN-  
Rail/panel mount holders up to 30 A  
Finger-safe Optima™ Class CC, UL supplemental and IEC 10x38mm  
DIN-Rail/panel mount protection modules up to 30 A  
Online resources  
Visit Eaton.com/bussmannseries for:  
ꢀ  
CAD drawings  
ꢀ  
Instruction sheets  
ꢀ  
UL information  
IEC specifications  
RD30-3  
RD200-3  
RD600-3  
Catalog no.  
RD30-3 RD60-3 RD100-3 RD100-3-SCCR RD200-3 RD400-3 RD600-3 RD800-3 RD1000-3 RD1200-3  
3-pole  
4-pole  
30  
800  
8
60  
800  
8
100  
800  
8
100  
1000  
8
RD200-4 RD400-4 RD600-4 RD800-4 RD1000-4 RD1200-4  
Thermal current Ith @ 40°C (A)  
Rated insulation voltage Ui (V)  
Rated impulse withstand voltage Uimp (kV)  
Rated operation currents Ie (A)  
200  
1000  
8
400  
1000  
8
1000  
12  
1000  
12  
1000  
12  
1000  
12  
Load duty  
Rated voltage (Vac)  
A 1  
32  
A 1  
63  
A 1  
A 1  
A 1  
A 1  
A 1  
A 1  
A 1  
A 1  
category  
AC-22 A  
AC-23 A  
AC-22 A  
AC-23 A  
1200  
1000  
630  
400  
690  
100  
630  
800  
1000  
400  
315  
100  
200  
80  
63  
500  
200  
630  
400  
630  
400  
400  
Operational power (Vac) in AC-23 (kW)  
400 V w/o prebreak AC 1, 2  
51  
63  
90  
100  
140  
185  
220  
280  
185  
355  
450  
185  
450  
560  
400  
15  
560  
400  
560  
400  
500 V w/o prebreak AC 1, 2  
30  
12  
45  
12  
690 V w/o prebreak AC 1, 2  
18.5  
Overload capacity (Ue 415 Vac)  
Rated short-circuit making capacity Icm (kA peak) 3  
Fuse protected short-circuit withstand  
(kA RMS prospective)  
Short-circuit current (kA) 3  
Associated fuse rating (A) 3  
12  
17. 6  
32  
48  
48  
75  
48  
75  
50  
32  
50  
63  
25  
100  
200  
100  
200  
400  
100  
630  
100  
800  
100  
1000  
100  
1250  
200  
Connection  
Minimum Cu cable cross section (mm2)  
Minimum Cu busbar section (mm2)  
Maximum Cu cable section (mm2)  
2.5  
70  
2.5  
70  
10  
70  
35  
300  
70  
300  
185  
600  
2x150  
2x30x5  
2x185  
2x40x5  
2x240  
2x50x5  
2x60x5  
1 A/B: Category with index A = frequent operation; category with index B = infrequent operation.  
2 The power value is given for information only; the current values vary from one manufacturer to another.  
3 For a rated operating voltage, Ue = 400 Vac.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-71  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL specifications  
RD30-3  
RD200-3  
RD600-3  
Catalog no.  
RD100-3-  
SCCR  
UL 98  
100 A  
Standard  
Front  
3-pole  
4-pole  
UL standard  
Max ampacity  
Switch type  
Handle operation  
UL electrical ratings  
Max voltage (AC)  
Max voltage (DC)  
RD30-3  
UL 98  
30 A  
Compact  
Front/Side  
RD60-3  
UL 98  
60 A  
Compact  
Front/Side Front/Side  
RD100-3  
UL 98  
100 A  
RD200-3  
RD200-4  
UL 98  
200 A  
Standard  
Front  
RD400-3  
RD400-4  
UL 98  
400 A  
Standard  
Front  
RD600-3  
RD600-4  
UL 98  
600 A  
Standard  
Front  
RD800-3 RD1000-3 RD1200-3  
RD800-4 RD1000-4 RD1200-4  
UL 98  
800 A  
Standard  
Front  
UL 98  
1000 A  
Standard  
Front  
UL 98  
1200 A  
Standard  
Front  
Compact  
600 Vac  
2
600 Vac  
600 Vac  
600 Vac  
250 Vdc  
600 Vac  
250 Vdc  
600 Vac  
600 Vac  
250 Vdc  
600 Vac  
600 Vac  
600 Vac  
1-phase, 120  
3
5
1-phase, 240  
3-phase, 240  
3-phase, 480  
3-phase, 600  
125  
5
10  
20  
40  
50  
10  
20  
50  
50  
10  
30  
75  
100  
10  
75  
150  
200  
Max. AC Hp  
ratings  
10  
20  
25  
125  
250  
350  
200  
400  
350  
20  
200  
500  
500  
200  
500  
500  
200  
500  
500  
DC Hp ratings  
250  
50  
Electrical characteristics  
SCCR with fuse (kA)  
Fuse class  
100  
J
100  
J
25 /100*  
J
200  
J
200  
J
200  
J
200  
J
100  
L
100  
L
100  
L
Max. fuse rating (A)  
Terminal lugs/kits  
Lug mounting torque - lb-in  
(N•m)  
30  
Integral  
60  
Integral  
100  
Integral  
10A  
200  
400  
600  
800  
1000  
1200  
LUG2-_ 310 (35)  
LUG3-_ 398 (45)  
160 (18)  
75°C Cu/ Al  
160 (18)  
75°C Cu/ Al  
310 (35)  
310 (35)  
310 (35)  
310 (35)  
75°C Cu/  
Al  
Wire type  
Solid  
75°C Cu  
75°C Cu  
75°C Cu  
75°C Cu/ Al  
75°C Cu/ Al  
75°C Cu/ Al 75°C Cu/ Al  
12-10,  
35.4 (4)  
12-10,  
35.4 (4)  
12-10,  
35.4 (4)  
(2) 2-600  
(4) 2-600  
(4) 2-600  
(4) 2-600  
10-1,  
35.4 (4)  
10-1,  
35.4 (4)  
10-1,  
35.4 (4)  
6-300 kcmil, 6-300 kcmil,  
275 (31) 275 (31)  
LUG2-_ 4-600  
kcmil, 550 (62)  
kcmil, 375 kcmil, 375 kcmil, 375 kcmil, 375  
(42.4)  
(42.4)  
(42.4)  
(42.4)  
Wire range  
and torque -  
lb-in (N•m)  
1/0, 39.8  
(4.5)  
1/0, 39.8  
(4.5)  
1/0, 39.8  
(4.5)  
2/0, 44.3  
(5)  
Dual 1/0-250  
kcmil, 550 (62)  
LUG3-_: (2) 6-2,  
200 (22.6)  
Stranded  
2/0, 44.3 (5) 2/0, 44.3 (5)  
(2) 1-350 kcmil,  
375 (42.4)  
Mechanical characteristics  
Endurances/Cycles  
10,000  
10,000  
10,000  
10,000  
8000  
6000  
6000  
3500  
3500  
3500  
Physical characteristics  
Dimensions  
See drawings on product pages  
3-pole  
4-pole  
1.3 (0.6)  
1.3 (0.6)  
1.3 (0.6)  
4.2 (1.91)  
4.2 (1.91)  
5.0 (2.3)  
10.0 (4.6)  
12.3 (5.6)  
18.1 (8.2)  
23.9 (10.9) 25.3 (11.5) 25.3 (11.5)  
19.6 (8.9)  
19.6 (8.9)  
19.6 (8.9)  
25.3 (11.5)  
Weight - lbs  
(kg)  
Environmental  
-20 to  
70°C  
UL 94-V0  
Operating Temperature  
-20 to 70°C -20 to 70°C  
-20 to 70°C  
UL 94-V0  
-20 to 70°C  
UL 94-V0  
-20 to 70°C  
UL 94-V0  
-20 to 70°C -20 to 70°C -20 to 70°C -20 to 70°C  
Flammability Rating  
UL 94-V0  
UL 94-V0  
UL 94-V0  
UL 94-V0  
UL 94-V0  
UL 94-V0  
Accessories  
3-pole  
Lug kit cat. no.  
4-pole  
Integral  
Integral  
Integral  
NEMA 1,  
3R, 12  
NEMA 1, 3R,  
4, 4X, 12  
Direct  
Front Pistol  
Front or Side  
Selector  
Handles  
Shaft c/s - mm  
Shaft guide  
Shrouds  
5x5  
5x5  
5x5  
10x10  
10x10  
10x10  
12x12  
12x12  
12x12  
••  
12x12  
Additional pole accessory  
NO + NC  
(2) NO  
Auxiliary  
contacts  
• Available, see product page for details and catalog numbers.  
Not available.  
* 25 kA @ 600 Vac, 100 kA @ 480 Vac.  
11-72  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 98 non-fused rotary disconnect switches — 30, 60 and compact 100 A  
For a complete assembly, select:  
Switch  
Max horsepower rating  
1-phase  
120 220/240 220/240  
3-phase  
440/480  
Conductor  
Amps  
30  
60  
Poles  
3
SCCR (kA)  
100  
600 AWG size/type  
25  
50  
50  
Catalog no.  
RD30-3  
RD60-3  
2
3
5
5
10  
10  
10  
20  
20  
20  
40  
50  
10-2/0 Str/12-10 Sol  
75°C Cu  
100  
25/100*  
RD100-3  
* 100 kA @480 Vac, 25 kA @ 600 Vac.  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
All switches  
Color  
Black  
Test function  
N
Padlockable  
Y - On Switch  
Catalog no.  
DIR-02  
OR  
External front or right side operated selector handles - shaft required  
1
2
Handle  
NEMA type  
Color  
Test function  
N
Padlockable  
Y
Catalog no.  
length  
Short  
Short  
Long  
Long  
Black  
Red/yellow  
Black  
H4X-01B (1)  
H4X-01R (1)  
H4X-02B (2)  
H4X-02R (2)  
1, 3R, 4, 4X, 12  
Red/yellow  
Or  
External front operated pistol handles - shaft required  
Handle  
NEMA type  
Color  
Test function  
N
Padlockable  
Defeatable  
Y
Catalog no.  
length  
Black  
Red/yellow  
H4X-03B  
H4X-03R  
1, 3R, 4, 4X, 12  
Y
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
Handle  
NEMA type  
Color  
Test function  
N
Padlockable  
Y
Defeatable  
Y
Catalog no.  
length  
Black  
Red/yellow  
H4X-03BHD  
H4X-03RHD  
1, 3R, 4, 4X, 12  
+
Shafts for selector handles  
Length — in (mm) Mounting depth (X) — in (mm)  
Catalog no.  
SH4-150 (1)  
SH4-200 (1)  
SH4-320 (1)  
1
5.9 (150)  
7.9 (200)  
12.6 (320)  
3.50~7.60 (89~193)  
3.50~9.50 (89~241)  
3.50~14.9 (89~378)  
Shafts for pistol handles  
Length — in (mm) Mounting depth (X) - in (mm)  
Catalog no.  
SH3-200 (2)  
SH3-320 (2)  
SH3-400 (2)  
2
7.9 (200)  
3.30~7.40 (84~188)  
3.30~9.30 (84~236)  
3.30~14.7 (84~373)  
12.6 (320)  
15.7 (400)  
+
Shaft guide for selector handles  
Catalog no.  
SH-GUIDE1  
Required for 12.6" (320mm) long shafts, optional for other lengths  
Shaft guide for pistol handles  
Catalog no.  
SH-GUIDE2  
Required for 15.7î (400mm) long shafts, optional for other lengths  
AND...  
Auxiliary contacts  
Continuous amp  
Max number of units per  
switch  
2 (1 per side/4 contacts  
total)  
2 (1 per side/4 contacts  
total)  
Contact type  
NO + NC  
NO  
No. of contacts  
Voltage (Vac)  
240  
Catalog no.  
BAC01  
rating  
1 of each  
2
10  
BAC02  
AND...  
Terminal shrouds - includes terminal shroud for both lineside and loadside  
Switch  
Poles  
Location on switch  
Lineside and loadside  
Catalog no.  
amps  
1 (for switched 4th pole)  
3
TSH3-1TB  
TSH3-3TB  
All switch-  
es  
AND...  
Switched 4th Pole - converts 3-pole switch to 4-pole  
Switch amps  
Catalog no.  
POLE98-30  
POLE98-60  
POLE98-100  
30  
60  
100  
Auxiliary contact  
configurations  
Possible 4th pole  
configurations  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-73  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Dimensions - in (mm)  
Direct handle operation  
External front operation  
External right side operation  
3.94 min./14.65 max.  
1.42  
36  
2.95  
100 min./372 max.  
3.07  
78  
75  
3.19  
81  
2.52  
64  
3.07  
2.52  
1
1.42  
36  
1.18 min./7.91 max.  
1.02  
78  
64  
2
30 min./201 max.  
26  
1.02  
26  
0.51  
13  
1
1.99  
50.6  
2
1
1
2
2
0.24  
6
0.35 1.02 1.02  
26 26  
0.35  
1.02  
26 8.8  
8.8  
2.09  
53  
0.34 1.02  
8.8 26  
1.02  
26  
M5  
1.02  
0.34  
0.26  
6
M5  
26 8.8  
2.08  
53  
1. Position for 1 switched 4th pole (1 per device max.) or 1 auxiliary contact.  
2. Position for 1 auxiliary contact only.  
Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one switched 4th pole.  
External front/right side operated selector handle, front operated pistol handle  
Handle type  
Door drilling layouts  
Ø3.07  
Ø78  
1.57  
40  
0.11  
3
4 Ø 0.27  
4 Ø 7  
Direction of  
front operation  
Direction of  
right side operation  
Selector  
H4X-01_  
1.42  
36  
I
I
Ø3.07  
Ø78  
Ø 1.22  
Ø 31  
Ø
Ø
0.88  
22.5  
0
0
With mounting nut  
With 4 Mounting Screws  
Selector  
H4X-02_  
1.45  
37  
1.57  
40  
4 Ø 0.27  
4 Ø 7  
H4X-03_ with 4 mounting screws  
Pistol  
H4X-03_  
Ø 1.45in/37mm screw clip (from front)  
Ø 1.22in/31mm screw (from rear)  
11-74  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 98 non-fused rotary disconnect switches—100, 200 and compact 400 A  
For a complete assembly, select:  
Switch  
Max horsepower rating  
1-phase  
SCCR (kA) 220/240  
3-phase  
440/480  
75  
Amps  
100  
Poles  
3
220/240  
30  
75  
600  
100  
200  
200  
350  
350  
Catalog no.  
RD100-3-SCCR  
RD200-3  
RD200-4  
RD400-3  
10  
10  
150  
200  
400  
4
3
4
200  
10  
-
-
75  
125  
125  
150  
250  
250  
RD400-4  
+
Terminal lug kit  
Switch  
amps  
Poles  
Lugs per kit  
Conductor AWG size/type  
Catalog no.  
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
2
3
4
LUG1-2  
LUG1-3  
LUG1-4  
LUG2-2  
LUG2-3  
LUG2-4  
LUG3-2  
LUG3-3  
LUG3-4  
6-300 kcmil  
75°C Cu/ Al  
100-200  
4-600 kcmil or Dual 1/0-250 kcmil  
75°C Cu/ Al  
400  
(2) 6-350 kcmil  
75°C Cu/ Al  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
Test  
For switch cat. no.  
All switches  
Color  
Black  
Padlockable  
Y
Catalog no.  
DIR-03  
function  
N
OR  
External front operated pistol handles - shaft required  
Test  
NEMA type  
1, 3R, 12  
Color  
Padlockable Defeatable Catalog no.  
function  
Black  
Red/yellow  
Black  
H12-03B  
H12-03R  
N
Y
Y
H4X-06B  
H4X-06R  
Or  
1, 3R, 4, 4X, 12  
Red/yellow  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
Test  
NEMA type  
Color  
Padlockable Defeatable Catalog no.  
H4X-06BHD  
function  
Black  
Red/yellow  
1, 3R, 4, 4X, 12  
N
Y
Y
H4X-06RHD  
+
+
Shafts for pistol handles  
Length — in (mm)  
7.9 (200)  
12.6 (320)  
Mounting depth (X) - in (mm)  
5.31~10.43 (135~265)  
5.31~15.16 (135~385)  
5.31~18.31 (135~465)  
Catalog no.  
SH5-200  
SH5-320  
SH5-400  
15.7 (400)  
Shaft Guide  
Catalog no.  
SH-GUIDE2  
Required for 15.7î (400mm) long shafts, optional for other lengths  
AND...  
Auxiliary contacts  
Contact  
type  
No. of  
contacts  
Voltage  
Vac  
Max number of aux  
contacts per switch  
Continuous amp rating  
Catalog no.  
NO + NC  
NO + NC  
NO + NC  
NO + NC  
BAC03*  
BAC04*  
BAC11*  
BAC12*  
10.1  
125-250  
1 of each  
2
1
125  
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.  
AND...  
Terminal shrouds - includes terminal shroud for Lineside or loadside  
Switch  
Poles  
Location on switch  
Catalog no.  
amps  
Lineside  
Loadside  
Lineside or loadside  
Lineside  
Loadside  
Lineside or loadside  
TSH4-3T  
TSH4-3B  
TSH4-4TB  
TSH5-3T  
TSH5-3B  
TSH5-4TB  
3
4
3
4
100-200  
400  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-75  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Dimensions — in (mm)  
M
J1  
U
Z
Y
1
W
R1  
R2  
T
AD  
C
F
Switch Overall  
amps dim. C  
Terminal shrouds  
Switch body  
Switch mounting  
M 3p. M 4p. R1  
5.31 0.35 0.27  
(210) (135) (9) (7)  
8.27 5.31 0.35 0.27  
(210) (135) (9) (7)  
10.6 7.67 0.35 0.27  
(270) (195) (9) (7)  
Connection  
AC  
10.1  
(256)  
10.1  
(256)  
16  
AD  
F 3p.  
7.09  
(180)  
7.09  
(180)  
9.05  
(230)  
F 4p.  
9.06  
(230)  
9.06  
(230)  
11.4  
H
J1 3p. J1 4p.  
K
1.8  
N
R2  
T
U
V
W
Y
Z
A A  
6.3  
(160)  
6.3  
(160)  
10.2  
(260)  
AC  
0.6  
(15)  
0.6  
(15)  
0.8  
(20)  
4.22  
(107)  
4.22  
(107)  
6.53  
(166)  
2.17  
(55)  
2.17  
(55)  
2.95  
(75)  
4.13  
6.3  
(160)  
6.3  
(160)  
8.26  
(210)  
8.27  
1.97  
(50)  
1.97  
(50)  
2.56  
(65)  
0.98  
(25)  
0.98  
(25)  
1.77  
(45)  
1.18  
(30)  
1.18  
(30)  
1.97  
(50)  
0.43 0.14 1.35  
(11) (4) (34)  
0.43 0.14 1.35  
100  
200  
400  
3.72 (95)  
3.72 (95)  
4.92 (128)  
3.05 (78)  
(105)  
4.13  
(105)  
5.31  
(135)  
(46)  
1.8  
(46)  
2.65  
(68)  
3.05 (78)  
4.15 (115)  
(11)  
0.43  
(13)  
(4)  
0.2  
(5)  
(34)  
2.08  
(53)  
(406)  
(290)  
DIR-03 direct mount handle  
External front handle  
1.57  
40  
1.79  
45.5  
Handle type  
Direction of front operation  
I
Door drilling layout  
Ø 1.46  
Ø3.07  
Ø78  
Ø 37  
4 Ø 0.27  
4 Ø 7  
H4X-06__  
H12-03__  
1.77  
45  
TEST  
0.55  
0.55  
14  
14  
Terminal lugs  
0.88  
Ø 0.4  
Ø 4.7  
73.15  
2.31  
58.67  
0.45  
Ø11.6  
0.53  
13.46  
2.8  
0.63  
71.5  
15.88  
1.52  
38.8  
0.46  
11.68  
1.19  
30.23  
0.25  
6.35  
LUG1-_ 100 to 200 A  
LUG2-_ 400 A  
LUG3-_ 400 A  
11-76  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 98 non-fused rotary disconnect switches — 600, 800, 1000 and 1200 A  
For a complete assembly, select:  
Switch  
Max horsepower rating  
3-phase  
440/480  
400  
400  
500  
500  
500  
500  
500  
DC*  
SCCR  
(kA)  
Amps  
600  
Poles  
220/240  
240  
240  
200  
200  
200  
200  
200  
200  
600  
350  
350  
500  
500  
500  
500  
500  
500  
125  
20  
20  
-
-
-
-
-
-
250 Catalog no.  
3
4
3
4
3
4
3
4
50  
RD600-3  
RD600-4  
RD800-3  
RD800-4  
RD1000-3  
RD1000-4  
RD1200-3  
RD1200-4  
200  
50  
-
-
-
-
-
-
800  
1000  
1200  
100  
500  
* DC ratings use two poles in series.  
+
Terminal lug kit  
Conductor AWG  
size/type  
(2) 2-600 kcmil  
75°C Cu/ Al  
Switch amps  
600  
Poles  
Lugs per kit  
Lugs required per pole  
1
Catalog no.  
3
4
3
4
3
4
6
8
LUG5-3  
LUG5-4  
LUG6-6  
LUG6-8  
(4) 2-600 kcmil  
75°C Cu/ Al  
800-1200  
2
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
Color  
Test function  
Padlockable  
Catalog no.  
DIR-04  
All switches  
Black  
N
Y
OR  
External front operated pistol handles - shaft required  
1
3
2
4
NEMA type  
Color  
Black  
Test function Padlockable  
Defeatable  
Y
Catalog no.  
H4X-07B (1)  
H4X-07R (1)  
H4X-08B (2)  
H4X-08R (2)  
Red/yellow  
Black  
1, 3R, 4, 4X, 12  
N
Y
Red/yellow  
Or  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Test function Padlockable  
Defeatable  
Y
Catalog no.  
H4X-07BHD (3)  
H4X-07RHD (3)  
H4X-08BHD (4)  
H4X-08RHD (4)  
Red/yellow  
Black  
Red/yellow  
1, 3R, 4, 4X, 1  
N
Y
+
+
Shafts for pistol handles  
Length — in (mm)  
7.9 (200)  
12.6 (320)  
15.7 (400)  
Mounting depth (X) — in (mm)  
8.70~13.50 (221~343)  
8.70~18.23 (221~463)  
8.70~21.38 (221~543)  
Catalog no.  
SH6-200  
SH6-320  
SH6-400  
Shaft guide  
Catalog no.  
SH-GUIDE2  
Required for 15.7" (400mm) long shafts, optional for other lengths  
AND...  
Auxiliary contacts  
Max number of aux contacts  
per switch  
Contact type No. of contacts Continuous amp rating Voltage (Vac)  
Catalog no.  
NO + NC  
NO + NC  
NO + NC  
NO + NC  
1 of each  
1 of each  
1 of each  
1 of each  
BAC03*  
BAC04*  
BAC11*  
BAC12*  
10.1  
1
125-250  
125  
2
* For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.  
AND...  
Terminal shrouds* — includes terminal shroud for lineside or loadside  
Switch amps  
Poles  
Location on switch  
Catalog no.  
TSH6-3TB  
TSH6-4TB  
TSH7-3TB  
TSH7-4TB  
3
4
3
4
600  
Lineside or loadside  
800-1200  
* Shroud for lineside included with switch.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-77  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Dimensions — in (mm)  
600 A  
800 to 1200 A  
Switch body  
H
Switch mounting  
M 4p.  
6.59 (168) 10.03 (255) 13.19 (335) 6.88 (175) 2.34 (60) 1.1 (28) 12.6 (320) 1.85 (47)  
Connection  
Switch  
amps  
Terminal  
shrouds B  
F 3p.  
F 4p.  
J 3p.  
J 4p.  
M 3p.  
N
N1  
N2  
A A  
Z
600  
18.12 (460)  
11 (280)  
14.17 (360) 5.5 (140)  
5 (128)  
800  
18.12 (460) 14.64 (372) 19.37 (492) 5.5 (140) 6.83 (174) 9.19 (234) 13.66 (347) 18.38 (467) 6.88 (175) 2.34 (60) 1.1 (28)  
18.12 (460) 14.64 (372) 19.37 (492) 5.5 (140) 6.83 (174) 9.19 (234) 13.66 (347) 18.38 (467) 6.88 (175) 2.34 (60) 1.1 (28)  
18.12 (460) 14.64 (372) 19.37 (492) 5.5 (140) 6.83 (174) 9.19 (234) 13.66 (347) 18.38 (467) 6.88 (175) 2.34 (60) 1.1 (28)  
13 (330)  
13 (330)  
13 (330)  
1.85 (47)  
1.85 (47)  
1.85 (47)  
1000  
1200  
DIR-04 Direct mount handle  
External front pistol handles  
2.36  
60  
Direction of Front Operation  
Handle Type  
I
Ø3.07  
Ø78  
Door drilling layout  
Ø 1.46  
Ø 37  
4 Ø 0.27  
4 Ø 7  
H4X-07__  
2.4  
3.35  
85  
61  
Terminal lugs  
I
Ø3.07  
Ø78  
0.55  
14  
0.55  
14  
0
2.36  
60  
H4X-08__  
LUG5-__, LUG6-__ 600 to 1200 A  
3.76  
95.5  
0.40  
Ø10.2  
3.15  
80  
11-78  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 508 non-fused rotary disconnect switches —  
16 to 80 A  
Eaton UL 508 load break disconnect switches allow safe control and  
safe disconnection of any motor application or to isolate a circuit  
within the panel.  
These disconnect switches are compact and offer a wide variety of  
accessories like 4th poles, Auxiliary contacts, door mounting and  
6/8-Pole kits.  
Features  
ꢀ  
Suitable for motor disconnect  
ꢀ  
DIN-Rail or panel mount  
ꢀ  
Door mount option  
ꢀ  
Disconnect switches are front, right side or direct handle operable  
ꢀ  
Finger-safe  
Agency information  
Related Bussmann series products  
ꢀ  
UL 508, Guide NLRV, File E155129  
Fuse blocks  
Modular Class H(K), J and RK fuse blocks up to 600 A  
Modular Class H(K), J and RK power distribution fuse blocks up to 400 A  
Modular, finger-safe CH Class CC and J, and UL supplemental and IEC  
10x38mm DIN-Rail holders up to 60 A  
Finger-safe Optima Class CC, UL supplemental and IEC 10x38mm DIN-  
Rail/panel mount holders up to 30 A  
Finger-safe Optima™ Class CC, UL supplemental and IEC 10x38mm  
DIN-Rail/panel mount protection modules up to 30 A  
ꢀ  
CSA C22.2 No. 14, File 257020  
ꢀ  
Conforms with IEC 60947-3  
Online resources  
Visit Eaton.com/bussmannseries for:  
ꢀ  
CAD drawings  
ꢀ  
Instruction sheets  
ꢀ  
UL information  
IEC specifications  
RD16-3-508  
RD16-3-508 with 6-pole conversion kit  
Catalog no.  
RD16-3-508  
RD25-3-508  
RD40-3-508  
RD63-3-508  
RD80-3-508  
Thermal current Ith at 40°C (A)  
Rated insulation voltage Ui (V)  
Rated impulse withstand voltage Uimp (kV)  
16  
800  
8
25  
800  
8
40  
800  
8
63  
800  
8
80  
800  
8
Rated operation currents Ie (A)  
Load duty category  
Rated voltage  
A/B 1  
16/16  
16/16  
16/16  
16/16  
16/16  
A/B 1  
25/25  
25/25  
25/25  
25/25  
25/25  
A/B 1  
40/40  
25/25  
40/40  
32/40  
25/25  
A/B 1  
63/63  
63/63  
63/63  
40/63  
40/40  
A/B 1  
80/80  
63/63  
80/80  
63/80  
40/40  
AC-22 A/ AC-22 B  
AC-23A/ AC-23 B  
AC-21 A/ AC-21 B  
AC-22 A/ AC-22 B  
AC-23A/ AC-23 B  
500  
690  
Operational power in AC-23 (kW)  
400 Vac without prebreak AC 1, 2  
500 Vac without prebreak AC 1, 2  
690 Vac without prebreak AC 1, 2  
Overload capacity (Ue 415 Vac)  
7. 5  
7. 5  
7. 5  
11  
11  
15  
18.5  
15  
18.5  
30  
30  
30  
37  
37  
37  
Rated short-time withstand current 0.3 s. ICW (kA  
2.5  
6
2.5  
6
2.5  
6
3
9
3
9
RMS) 3  
Rated short-time making capacity Icm (kA peak) 3  
Fuse protected short-circuit withstand (kA RMS prospective)  
Prospective short-circuit current (kA RMS) 3  
Associated fuse rating (A) 3  
50  
16  
50  
25  
50  
40  
50  
63  
50  
80  
Connection  
Minimum Cu cable cross section (mm2)  
Maximum Cu cable section (mm2)  
Tightening torque min/max (N•m)  
1.5  
16  
2/2.2  
1.5  
16  
2/2.2  
1.5  
16  
2/2.2  
2.5  
35  
3.5/3.85  
2.5  
35  
3.5/3.85  
1 A/B: Category with index A = frequent operation; category with index B = infrequent operation.  
2 The power value is given for information only; the current values vary from one manufacturer to another.  
3 For a rated operating voltage, Ue = 400 Vac.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-79  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL specifications  
RD16-3-508  
RD16-3-508 with 6-pole conversion kit  
Catalog no.  
UL standard  
RD16-3-508  
UL 508  
RD25-3-508  
UL 508  
RD40-3-508  
UL 508  
RD63-3-508  
UL 508  
RD80-3-508  
UL 508  
Max ampacity  
16 A  
25 A  
40 A  
63 A  
80 A  
Handle operation  
Front/Side  
Front/Side  
Front/Side  
Front/Side  
Front/Side  
UL ratings  
Max voltage (AC)  
3-phase, 208  
600 Vac  
600 Vac  
7. 5  
7. 5  
15  
20  
600 Vac  
7. 5  
7. 5  
20  
25  
600 Vac  
15  
20  
40  
40  
600 Vac  
15  
20  
40  
40  
3
5
10  
10  
3-phase, 240  
3-phase, 480  
Max. Hp ratings  
3-phase, 600  
Electrical characteristics  
SCCR with fuse (kA)  
65  
J
30  
65  
J
30  
10/65  
J
60/30  
50/65  
J
100/60  
50/65  
J
100/60  
Fuse class  
Max. fuse rating (A)  
Recommended upstream  
Terminals  
Wire type  
Integral  
Integral  
Integral  
75°C Cu  
14-10, 26.5 (3)  
12, 26.5 (3)  
14-4 , 26.5 (3)  
14-12, 26.5 (3)  
Integral  
75°C Cu  
14-10, 31.1 (3.5)  
12, 31.1 (3.5)  
14-1, 31.1 (3.5)  
10-6, 31.1 (3.5)  
Integral  
75°C Cu  
14-10, 31.1 (3.5)  
12, 31.1 (3.5)  
14-1, 31.1 (3.5)  
10-6, 31.1 (3.5)  
75°C Cu  
14-10, 26.5 (3)  
12, 26.5 (3)  
14-4, 26.5 (3)  
14-12, 26.5 (3)  
75°C Cu  
14-10, 26.5 (3)  
12, 26.5 (3)  
14-4, 26.5 (3)  
14-12, 26.5 (3)  
Solid single  
Solid dual  
Stranded single  
Stranded dual  
Wire range and torque - lb-in  
(N•m)  
Mechanical characteristics  
Endurances/cycles  
Physical characteristics  
Dimensions  
10,000  
10,000  
10,000  
10,000  
10,000  
See drawings on product pages  
Weight- lb (kg)  
0.5 (0.2)  
0.5 (0.2)  
0.5 (0.2)  
0.7 (0.32)  
0.7 (0.32)  
Environmental  
Operating temperature  
Flammability rating  
Accessories  
-20 to 70°C  
UL 94-V0  
-20 to 70°C  
UL 94-V0  
-20 to 70°C  
UL 94-V0  
-20 to 70°C  
UL 94-V0  
-20 to 70°C  
UL 94-V0  
Direct  
DIR-01  
H4X-01B  
H4X-01R  
H4X-02B  
H4X-02R  
H4X-03B  
H4X-03R  
H4X-03BHD  
H4X-03RHD  
SH4-150  
DIR-01  
H4X-01B  
H4X-01R  
H4X-02B  
H4X-02R  
H4X-03B  
H4X-03R  
H4X-03BHD  
H4X-03RHD  
SH4-150  
DIR-01  
H4X-01B  
H4X-01R  
H4X-02B  
H4X-02R  
H4X-03B  
H4X-03R  
H4X-03BHD  
H4X-03RHD  
SH4-150  
DIR-01  
H4X-01B  
H4X-01R  
H4X-02B  
H4X-02R  
H4X-03B  
H4X-03R  
H4X-03BHD  
H4X-03RHD  
SH4-150  
SH4-200  
SH4-320  
SH3-200  
SH3-320  
SH3-400  
SH-GUIDE1  
SH-GUIDE2  
DOOR-508  
DIR-01  
H4X-01B  
H4X-01R  
H4X-02B  
H4X-02R  
H4X-03B  
H4X-03R  
H4X-03BHD  
H4X-03RHD  
SH4-150  
SH4-200  
SH4-320  
SH3-200  
SH3-320  
SH3-400  
SH-GUIDE1  
SH-GUIDE2  
DOOR-508  
Short selector/NEMA 1, 3R, 4,  
4X, 12  
Long selector/NEMA 1, 3R, 4,  
4X, 12  
Handles  
Pistol handle/NEMA 1, 3R, 4,  
4X, 12  
Metallic hasp (HD) pistol handle/  
NEMA 1, 3R, 4, 4X, 12  
5.9"/150mm  
Selector handle shafts - 5x5mm 7.9"/200mm  
SH4-200  
SH4-320  
SH3-200  
SH3-320  
SH4-200  
SH4-320  
SH3-200  
SH3-320  
SH4-200  
SH4-320  
SH3-200  
SH3-320  
12.6"/320mm  
7.9"/200mm  
12.6"/320mm  
15.75"/400mm  
Pistol handle shafts - 5x5mm  
SH3-400  
SH3-400  
SH3-400  
Selector handle shaft guide  
Pistol handle shaft guide  
Door mount kit  
SH-GUIDE1  
SH-GUIDE2  
DOOR-508  
TSH1-1TB  
TSH1-3TB  
POLE-16  
SH-GUIDE1  
SH-GUIDE2  
DOOR-508  
TSH1-1TB  
TSH1-3TB  
POLE-25  
SH-GUIDE1  
SH-GUIDE2  
DOOR-508  
TSH1-1TB  
TSH1-3TB  
POLE-40  
1-Pole  
3-Pole (loadside and lineside)  
Switched 4th pole/switch amps  
TSH2-3TB  
TSH2-3TB  
Shrouds/switch amps  
Auxiliary contacts  
Ground module (conforms to IEC  
60947-3)  
Neutral module (conforms to IEC  
60947-3)  
NO + NC (1 ea.)  
(2) NO  
AC ratings  
Volts  
GND-16-40  
NTRL-16-40  
GND-16-40  
NTRL-16-40  
GND-16-40  
NTRL-16-40  
GND-63-80  
NTRL-63-80  
GND-63-80  
NTRL-63-80  
BAC01  
BAC02  
BAC01  
BAC02  
BAC01  
BAC02  
BAC01  
BAC02  
BAC01  
BAC02  
240 Vac  
10  
240 Vac  
10  
240 Vac  
10  
240 Vac  
10  
240 Vac  
10  
Amps  
6-/8-pole conversion kit gangs two switches of same rating, 16-80 A  
switch amps  
KIT-6POLE  
KIT-6POLE  
KIT-6POLE  
KIT-6POLE  
KIT-6POLE  
Not available.  
11-80  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 508 non-fused rotary disconnect switches —16, 25, 40, 63 and 80 A  
For a complete assembly, select:  
Switch  
Max. Class  
J fuse  
Max horsepower rating, 3-Phase  
SCCR @600V  
(kA)  
Conductor AWG size/  
Amps  
16  
25  
Poles  
3
amps  
208  
3
220/240 440/480  
600  
10  
20  
type  
Catalog no.  
RD16-3-508  
RD25-3-508  
5
10  
15  
65  
30  
14-10 Sol, Dual 12  
Sol, 14-4 Str, Dual  
14-12 Str, 75°C Cu  
7. 5  
7. 5  
10  
65  
50  
65  
50  
65  
60  
30  
100  
60  
100  
60  
40  
63  
80  
7. 5  
15  
15  
7. 5  
20  
20  
40  
40  
25  
40  
40  
RD40-3-508  
RD63-3-508  
RD80-3-508  
14-10 Sol, Dual 12  
Sol, 14-1 Str, Dual  
10-6 Str, 75°C Cu  
20  
PLUS  
Direct mount handle - mounts directly to switch, no shaft required  
For switch cat. no.  
Color  
Test function  
Padlockable  
Catalog no.  
DIR-01  
All switches  
Black  
N
Y - On Switch  
OR  
External front or right side operated selector handles - shaft required  
1
2
NEMA type  
Color  
Black  
Red/yellow  
Black  
Handle length  
Test function  
Padlockable  
Y
Catalog no.  
H4X-01B (1)  
H4X-01R (1)  
H4X-02B (2)  
H4X-02R (2)  
Short  
1, 3R, 4, 4X, 12  
N
Long  
Red/yellow  
Or  
External front operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Handle length  
Test function  
N
Padlockable  
Y
Defeatable  
Y
Catalog no.  
H4X-03B  
H4X-03R  
1, 3R, 4, 4X, 12  
Metallic hasp (heavy duty) external front operated pistol handles - shaft required  
NEMA type  
Color  
Black  
Red/yellow  
Handle length  
Test function  
Padlockable  
Y
Defeatable  
Y
Catalog no.  
H4X-03BHD  
H4X-03RHD  
1, 3R, 4, 4X, 12  
N
+
Shafts for selector handles  
Length — in (mm)  
5.9 (150)  
7.9 (200)  
Mounting depth (X) - in (mm)  
3.50~7.60 (89~193)  
3.50~9.50 (89~241)  
3.50~14.9 (89~378)  
Catalog no.  
SH4-150 (1)  
SH4-200 (1)  
SH4-320 (1)  
1
12.6 (320)  
Shafts for pistol handles  
Length — in (mm)  
7.9 (200)  
12.6 (320)  
Mounting depth (X) - in (mm)  
Catalog no.  
SH3-200 (2)  
SH3-320 (2)  
SH3-400 (2)  
2
3.30~7.40 (84~188)  
3.30~9.30 (84~236)  
3.30~14.7 (84~373)  
15.7 (400)  
+
+
Shaft guides for selector and pistol handles  
Handle type  
Catalog no.  
SH-GUIDE1  
Selector  
Required for 12.6" (320mm) long shafts, optional for other lengths  
Required for 15.7" (400mm) long shafts, optional for other lengths  
Pistol  
SH-GUIDE2  
Door mount kit  
For mounting switch on the right side of the enclosure or directly on the enclosure door using switch side operation shaft location. Kit  
includes a shaft. Order switch and selector handle separately.  
Switch  
Catalog no.  
All switches - kit includes shaft  
DOOR-508  
AND...  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-81  
Eaton.com/bussmannseries  
11 — Disconnect switches  
Auxiliary contacts  
No. of  
contacts  
1 Ea.  
Continuous amp  
rating  
Contact type  
NO + NC  
Voltage (Vac) rating  
Max number of units per switch Catalog no.  
BAC01  
10  
240  
2 (1 per side/4 contacts total)  
BAC02  
NO  
2
AND...  
Terminal shrouds - includes terminal shroud for both lineside and loadside  
Switch  
Poles  
amps  
Location on switch  
Catalog no.  
16-40  
16-40  
63-80  
1 (for switched 4th pole)  
TSH1-1TB  
TSH1-3TB  
TSH2-3TB  
Lineside and loadside  
3
AND...  
Switched 4th pole - converts 3-pole switch to 4-pole switch  
Switch amps  
Catalog no.  
POLE-16  
16  
25  
40  
POLE-25  
POLE-40  
AND...  
Ground and Neutral Modules - provides unswitched ground or neutral pole - conforms to IEC 60947-3  
Switch amps  
Module Type  
Catalog no.  
GND-16-40  
16-40  
Ground  
63-80  
16-40  
63-80  
GND-63-80  
NTRL-16-40  
NTRL-63-80  
Neutral  
AND...  
6-pole conversion kit - creates a 6-pole switch by ganging two 3-pole switches of equal rating  
Switch amps  
All switches  
Catalog no.  
KIT-6POLE*  
* Kit ships with a direct handle. If external handle is needed order a selector handle and shaft for the UL 508 Rotary Disconnect  
Switches.  
Note: To create an 8-pole switch from 16 to 40 amp switches, use two 3-pole switches of equal ratings plus two switched 4th poles  
(part # POLE-_).  
Order switches separately  
Auxiliary contact  
configurations  
Ground and neutral module, and  
switched 4th pole configurations.  
Dimensions — in (mm)  
1.42  
36  
E
F
D
2
1.42  
36  
2.95  
75  
3.19  
81  
2.52  
64  
1.99  
50.6  
M
F
2.52  
1
1
M
2
64  
J
1
2
1
2
0.24  
6
0.35 F1  
8.8  
F1 0.35  
8.8  
T
1.97  
50  
M5  
0.35  
8.8  
F1  
F1  
0.35  
8.8  
0.23  
T
6
1.96  
50  
M5  
Direct handle operation  
External front operation  
External side operation  
1. Position for 1 switched 4th pole (1 per device max.), or ground or neutral module (2 per device max.) or 1 auxiliary contact.  
2. Position for 1 auxiliary contact only.  
Note: Maximum of 4 Auxiliary contacts, or 3 Auxiliary contacts + one ground or neutral module, or one switched 4th pole.  
Overall dimensions  
D max E min  
Switch body  
F1  
Switch mounting  
Switch  
amps  
Terminal  
shroud AC  
D min  
E max  
F
G
J
M
N
Connection T  
0.59 (15)  
16 to 40 1.18 (30) 9.25 (235) 3.94 (100) 14.64 (372) 4.33 (110)  
63 to 80 1.18 (30) 9.25 (235) 3.93 (100) 14.64 (372) 4.33 (110)  
1.77 (45) 0.59 (15) 2.67 (68)  
2.06 (53) 0.69 (18) 2.99 (76)  
0.59 (15)  
1.18 (30) 2.95 (75)  
0.69 (18) 1.38 (35) 3.35 (85)  
0.69 (18)  
11-82  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
Dimensions — in (mm)  
F
F
J
J
3.50  
89  
3.07  
78  
F2  
F2  
1
1
1
1
E
1.42  
36  
X M  
2.06  
52.5  
X M  
2.06  
52.5  
2
2
2
2
0.24  
6
1.69 1.36  
0.35  
8.8  
0.35  
8.8  
0.35 F1  
8.8  
F1  
0.35 F1  
8.8  
F1  
0.29  
7.5  
0.29  
7.5  
T T  
2.06  
52.5  
T T  
2.06  
52.5  
34.7  
43  
Direct front operation for 6/8-pole disconnects  
External front operation for 6/8-pole disconnects  
1. Position for 1 switched 4th pole (1 per device max.) or 1 auxiliary contact.  
2. Position for 1 auxiliary contact only.  
Note: Maximum of 4 auxiliary contacts, or 3 auxiliary contacts + one switched 4th pole.  
Overall dimensions  
E max  
Switch body  
Switch mounting  
Connection  
Switch  
amps  
E min  
F
F1  
F2  
G
J
M
N
T
X
16 to 40 4.13 (105) 14.64 (372) 3.83 (98)  
0.59 (15)  
1.77 (45)  
2.06 (53)  
2.67 (68)  
2.99 (76)  
1.92 (48.75) 1.18 (30) 2.95 (75)  
0.59 (15)  
0.69 (18)  
0.29 (8)  
0.34 (9)  
63 to 80 4.13 (105) 14.65 (372) 4.13 (105) 0.69 (18)  
2.06 (52.5)  
1.38 (35) 3.35 (85)  
External selector and pistol handles  
Handle type  
Door drilling layouts  
Ø3.07  
Ø78  
1.57  
40  
0.11  
3
4 Ø 0.27  
4 Ø 7  
Direction of  
front operation  
Direction of  
right side operation  
Selector  
H4X-01_  
1.42  
36  
I
I
Ø3.07  
Ø78  
Ø 1.22  
Ø 31  
Ø
Ø
0.88  
22.5  
0
0
With mounting nut  
With 4 Mounting Screws  
Selector  
H4X-02_  
1.45  
37  
1.57  
40  
4 Ø 0.27  
4 Ø 7  
H4X-03_ with 4 mounting screws  
Pistol  
H4X-03_  
Ø 1.45in/37mm screw clip (from front)  
Ø 1.22in/31mm screw (from rear)  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-83  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL 98 and UL 508 enclosed disconnect switches  
Enclosed fused and non-fused rotary disconnect switches from 16 to  
1200 A in NEMA 1, 3R, 4, 4X, 12 enclosures.  
Ratings  
2011/65/EU  
ꢀ  
Volts  
600 Vac  
250-600 Vdc*  
ꢀ  
ꢀ  
Amps 16-1200 A  
SCCR  
NEMA 1, 3R, 4 and 12  
UL 98 25-200 kA  
UL 508 10-65 kA  
* Some non-fused disconnect switches are not rated for DC applications.  
Agency information  
ꢀ  
UL 98 Listed, Guide WIAX, WIAX7, File E182262  
ꢀ  
UL 508 Listed, Guide NLRV, NLRV, File E155129  
ꢀ  
cULus Listed to Canadian Standard 22.2, No. 14  
ꢀ  
cULus Listed to Canadian Standard 22.2, No. 4  
ꢀ  
Conforms with IEC 60947-3  
ꢀ  
RoHS compliant  
ꢀ  
CE  
NEMA 4X 304 stainless steel  
Operating temperature  
ꢀ  
-20ºC to 70ºC  
4X plastic enclosure flammability ratings  
ꢀ  
Polycarbonate UL 94-5V A-0  
ꢀ  
Fiberglass UL 94-5V  
Field installed accessories  
ꢀ  
Auxiliary contacts  
ꢀ  
Terminal shrouds  
Switched 4th pole (UL 508 only)  
ꢀ  
NEMA 4X polycarbonate or fiberglass  
Online resources  
Visit Eaton.com/bussmannseries for:  
ꢀ  
CAD drawings  
ꢀ  
Instruction sheets  
ꢀ  
UL information  
Features  
ꢀ  
UL 98 Listed for general purpose, main disconnect, or branch  
circuit protection up to 600 Vac/dc  
ꢀ  
UL 508 Listed for motor disconnect applications up to 600 Vac  
ꢀ  
Multiple field installed accessories enhance the enclosed  
disconnect switches to fit the desired application  
ꢀ  
Lockout/tagout: Up to three 1/4" shank padlocks can be installed  
on external handles  
11-84  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 98 enclosed fused disconnects — 30 to 800 A  
3-pole UL 98 600 Vac  
Catalog number system:  
ER 4X  
-
60  
J
3
P
B
ER  
Enclosed Rotary disconnect  
NEMA 1, 3R, 4 and 12  
NEMA 4X  
304 stainless steel  
NEMA 4X  
NEMA rating  
1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12  
Amp rating  
30-800A UL 98 fused switches  
30, 60, 100, 200, 400, 600, 800  
Fuse class  
Available Bussmann series fuses  
J = Class J, L = Class L  
Number of poles  
3 = 3-pole  
Fuse class Catalog symbol/type  
LPJ time-delay, current limiting  
JKS fast-acting fuses  
J
Handle type  
DFJ high speed drive fuse  
KRP-C time-delay, current limiting  
KTU fast-acting  
P = Pistol  
Handle color  
L
KLU time-delay  
B = Black, R = Red  
KRP-CL (225-600 A)  
Catalog numbers  
All catalog numbers provided with integral or installed lugs and a  
black selector handle. Order Red/yellow handle by changing the  
suffix “B” to “R.”  
NEMA enclosure type and catalog no.  
Switch amps  
Fuse class  
1
3R  
4
4X plastic1  
ER4P-30J3PB  
ER4P-60J3PB  
ER4P-100J3PB  
ER4P-200J3PB  
ER4P-400J3PB  
ER4P-600J3PB  
ER4P-800L3PB  
4X 304 stainless  
12  
30  
60  
ER1-30J3PB  
ER1-60J3PB  
ER1-100J3PB  
ER1-200J3PB  
ER1-400J3PB  
ER1-600J3PB  
ER1-800L3PB  
ER3R-30J3PB  
ER3R-60J3PB  
ER3R-100J3PB  
ER3R-200J3PB  
ER3R-400J3PB  
ER3R-600J3PB  
ER3R-800L3PB  
ER4-30J3PB  
ER4-60J3PB  
ER4X-30J3PB  
ER4X-60J3PB  
ER4X-100J3PB  
ER4X-200J3PB  
ER4X-400J3PB  
ER4X-600J3PB  
ER4X-800L3PB  
ER12-30J3PB  
ER12-60J3PB  
ER12-100J3PB  
ER12-200J3PB  
ER12-400J3PB  
ER12-600J3PB  
ER12-800L3PB  
100  
200  
400  
600  
800  
ER4-100J3PB  
ER4-200J3PB  
ER4-400J3PB  
ER4-600J3PB  
ER4-800L3PB  
J
L
1 Enclosures 100 A are polycarbonate, flammability rating UL 94-5V A-V0, 200 A  
are fiberglass, flammability rating UL 94-5V.  
Switch ratings  
For wire types, ranges and terminal torques, see table on page 11-55.  
Voltage  
Switch amps  
Switch cat. no.  
Fuse class  
Poles  
Vac  
Vdc  
SCCR @ Vac (kA)  
Max. Hp @ 600 Vac  
30  
RDF30J-3  
20  
250  
60  
RDF60J-3  
RDF100J-3  
RDF200J-3  
RDF400J-3  
50  
75  
150  
350  
100  
200  
400  
J
N/A  
250  
3
600  
200  
600  
800  
RDF600J-3  
RDF800L-3  
600  
500  
L
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-85  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL 98 enclosed fused disconnects — 30 to 800 A  
W
Enclosure weights and dimensions  
Mounting centers h x w (in)  
Catalog no.  
family  
Fuse  
class  
NEMA  
enclosure  
1, 3R, 4, 12  
4X-SST  
4X-plastic 1  
1, 3R, 4, 12  
4X-SST  
4X-plastic 1  
1, 3R, 4, 12  
4X-SST  
4X-plastic 1  
1, 3R, 4, 12  
4X-SST  
4X-plastic 1  
1, 3R, 4, 12  
4X-SST  
4X-plastic 1  
1, 3R, 4, 12  
4X-SST  
Amps  
H x W x D (in)  
A
B
C
Weight (lbs)  
MH H  
A
8.3x8.3  
10.3x8.3  
10x10x6  
15  
8
ER_-30J  
30  
10.7x8.3  
12x5.6  
8.3x10.7  
7.6x10  
12x10x6  
19  
ER_-60J  
60  
12.7x8.3  
14x7.6  
8.3x10.7  
9.6x12  
MW  
W
13x13x6  
14x12x6  
11  
12.3x10.3  
21  
14.7x10.3  
14x7.6  
12.3x12.7  
9.6x12  
ER_-100J  
ER_-200J  
ER_-400J  
ER_-600J  
ER_-800L  
100  
200  
400  
600  
800  
13x13x6  
12  
J
22.3x18.3  
24x20x8  
27x21x10  
48x36x12  
51x37x14  
48x36x12  
51x37x14  
48x36x12  
51x37x14  
55  
24.7x18.3  
25.75x14  
22.3x20.7  
H
MH  
39  
B
46.3x34.3  
188  
186  
216  
214  
216  
214  
48.7x34.3  
50x28.5  
46.3x36.7  
46.3x34.3  
MW  
W
48.7x34.3  
50x28.5  
46.3x36.7  
4X-plastic 1  
1, 3R, 4, 12  
4X-SST  
46.3x34.3  
L
48.7x34.3  
50x28.5  
46.3x36.7  
4X-plastic 1  
1 Enclosures 100 A are polycarbonate, flammability rating UL 94-5V A-V0, 200 A  
are fiberglass, flammability rating UL 94-5V.  
H
MH  
C
Available field-Installed accessories - order separately  
Auxiliary contacts - for 30 to 800 amp switches  
MW  
Contact type No. of contacts Cont. amp rating  
Vac  
Max. units per switch Catalog no.  
NO  
4 (30 to 200 A)  
8 (400 to 800 A)  
BAC05  
BAC06  
1
10  
600  
NC  
Terminal shrouds  
For 200 to 800 amp switches - includes terminal shroud for lineside  
or loadside  
Switch amps  
200  
Poles Catalog no.  
TSH8-3TB  
400  
3
TSH9-3TB  
600-800  
TSH10-3TB  
11-86  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 98 enclosed non-fused disconnects —  
30 to 1200 A  
3-pole UL 98 600 Vac  
Catalog number system:  
ER 4X  
-
60  
N
3
P
B
NEMA 1, 3R, 4 and 12  
NEMA 4X  
304 stainless steel  
NEMA 4X  
ER  
Enclosed Rotary disconnect  
200-1200A UL 98 non-fused switches  
NEMA rating  
1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12  
Amp rating  
30, 60, 100, 200, 400, 600, 800, 1200  
N = non-fused  
Number of poles  
3 = 3-pole  
Handle type  
NEMA 1, 3R, 4 and 12  
NEMA 4X  
304 stainless steel  
NEMA 4X  
P = Pistol  
30-800A UL 98 non-fused switches  
Handle color  
B = Black, R = Red  
Catalog numbers  
All Catalog numbers provided with integral or installed lugs and a black  
selector handle. Order Red/yellow handle by changing the suffix “B” to  
“R.”  
NEMA enclosure type and catalog no.  
Amps  
30  
60  
100  
200  
400  
600  
800  
1200  
1
3R  
4
4X plastic 1  
ER4P-30N3PB  
ER4P-60N3PB  
ER4P-100N3PB  
ER4P-200N3PB  
ER4P-400N3PB  
ER4P-600N3PB  
ER4P-800N3PB  
N/ A  
4X 304 stainless  
ER4X-30N3PB  
ER4X-60N3PB  
ER4X-100N3PB  
ER4X-200N3PB  
ER4X-400N3PB  
ER4X-600N3PB  
ER4X-800N3PB  
ER4X-1200N3PB  
12  
ER1-30N3PB  
ER1-60N3PB  
ER1-100N3PB  
ER1-200N3PB  
ER1-400N3PB  
ER1-600N3PB  
ER1-800N3PB  
ER1-1200N3PB  
ER3R-30N3PB  
ER3R-60N3PB  
ER3R-100N3PB  
ER3R-200N3PB  
ER3R-400N3PB  
ER3R-600N3PB  
ER3R-800N3PB  
ER3R-1200N3PB  
ER4-30N3PB  
ER4-60N3PB  
ER4-100N3PB  
ER4-200N3PB  
ER4-400N3PB  
ER4-600N3PB  
ER4-800N3PB  
ER4-1200N3PB  
ER12-30N3PB  
ER12-60N3PB  
ER12-100N3PB  
ER12-200N3PB  
ER12-400N3PB  
ER12-600N3PB  
ER12-800N3PB  
ER12-1200N3PB  
1 Enclosures 100 A are polycarbonate, flammability rating UL 94-5V A-V0, 200 A  
are fiberglass, flammability rating UL 94-5V.  
Switch ratings  
For wire types, ranges and terminal torques, see table on page 11-72.  
Amps Switch catalog no. Poles Vac SCCR (kA)  
Max. Hp @ 600 Vac  
30  
60  
RD30-3  
RD60-3  
25  
100  
50  
100  
200  
400  
600  
800  
1200  
RD100-3  
RD200-3  
RD400-3  
RD600-3  
RD800-3  
RD1200-3  
25/100*  
200  
350  
3
600  
200  
100  
500  
* 25 kA @ 600 Vac, 100 kA @ 480 Vac.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-87  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL 98 enclosed non-fused disconnects —  
30 to 1200 A  
W
Enclosure weights and dimensions  
MH H  
Mounting centers h x w (in)  
A
Catalog  
NEMA  
no. family Amps  
enclosure  
H x W x D (in)  
10x8x6  
A
B
C
Weight (lbs)  
1, 3R, 4, 12  
4X-SST  
4X-plastic (1)  
1, 3R, 4, 12  
4X-SST  
8.3x6.3  
11  
11  
5
ER_-30  
30  
60  
8.3x6.3  
10.7x6.3  
10x3.6  
8.3x8.7  
5.6x8  
MW  
W
9x9x6  
12  
10x8x6  
ER_-60  
10.3x8.3  
10.7x6.3  
10x3.6  
8.3x8.7  
5.6x8  
12  
5
12  
4X-plastic (1)  
1, 3R, 4, 12  
4X-SST  
4X-plastic (1)  
1, 3R, 4, 12  
4X-SST  
4X-plastic (1)  
1, 3R, 4, 12  
4X-SST  
4X-plastic (1)  
1, 3R, 4, 12  
4X-SST  
4X-plastic (1)  
1, 3R, 4, 12  
4X-SST  
4X-plastic (1)  
1, 3R, 4, 12  
4X-SST  
9x9x6  
12x10x6  
13x13x6  
20x16x8  
20x17x12  
36x30x8  
37x32x14  
48x36x12  
51x37x 14  
48x36x12  
51x37x 14  
ER_-100  
ER_-200  
ER_-400  
ER_-600  
100  
200  
400  
600  
12.7x8.3  
14x7.6  
20.7x14.3 18.3x16.7  
21.5x10.1  
8.3x10.7  
9.6x12  
12  
8
39  
39  
H
MH  
B
18.3x14.3  
31  
MW  
W
34.3x28.3  
122  
122  
103  
209  
209  
187  
211  
211  
189  
268  
268  
36.7x28.3 34.3x30.7  
38x28.9  
48.7x34.3 46.3x36.7  
50x28.5  
48.7x34.3 46.3x36.7  
50x28.5  
46.3x34.3  
H
MH  
C
46.3x34.3  
ER_-800  
800  
MW  
58.3x34.3  
60x36x16  
60x36x16  
ER_-1200  
1200  
60.7x34.3 58.3x36.7  
1 Enclosures 100 A are polycarbonate, flammability rating UL 94-5V A-V0, 200 A are fiberglass, flammability rating UL 94-5V.  
Available field-installed accessories - order separately  
Auxiliary contacts for 30 to 1200 amp switches.  
Switch amps Contact type No. of contacts Cont. amp rating  
Vac  
Max. units per switch Catalog no.  
NO + NC  
NO  
NO + NC  
NO + NC  
NO + NC  
NO + NC  
1 of each  
2
1 of each  
1 of each  
1 of each  
1 of each  
BAC01*  
BAC02*  
BAC03**  
BAC04**  
BAC11**  
BAC12**  
30-100  
10  
10.1  
1
240  
4
125-250  
125  
200-1200  
2
* Two (2) Units per switch max.  
**For one auxiliary contact, install either BAC03 or BAC11. For two auxiliary contacts, install BAC03 + BAC04, or BAC11 + BAC12.  
Terminal shrouds for 200 to 800 amp switches  
Switch amps  
Poles  
Location on switch  
Lineside and loadside  
Lineside  
Catalog no.  
TSH3-3TB  
TSH4-3T  
TSH4-3B  
TSH5-3T  
TSH5-3B  
TSH6-3TB  
TSH7-3TB  
30-100  
200  
400  
Loadside  
Lineside  
Loadside  
3
600  
800-1200  
Lineside or loadside  
11-88  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  
Disconnect switches — 11  
UL 508 enclosed non-fused disconnect — 16 to 80 A  
3-/6-pole UL 508 600 Vac  
Catalog number system:  
ER 4X  
-
63  
N
6
P
B
ER  
Enclosed Rotary disconnect  
NEMA rating  
NEMA 1, 3R, 4 and 12  
NEMA 4X  
NEMA 4X  
304 stainless steel  
1, 3R, 4, 4X (304 SST), 4P (4X Plastic), 12  
Amp rating  
16-80 A UL 508 non-fused switches  
16, 25, 40, 63, 80  
N = non-fused  
Number of poles  
3 = 3-pole, 6 = 6-pole  
Handle type  
S = Selector*, P = Pistol**  
Handle color  
B = Black, R = Red  
* 6-Pole switches only, selector handle does not interlock the enclosure door.  
**3-pole switches only.  
Catalog numbers  
All catalog numbers provided with a black selector handle. Order red/  
yellow handle by changing the suffix “B” to “R.”  
NEMA enclosure and catalog no.  
Amps  
Poles  
1
3R  
4
4X plastic 1  
ER4P-16N3PB  
ER4P-16N6SB  
ER4P-25N3PB  
ER4P-25N6SB  
ER4P-40N3PB  
ER4P-40N6SB  
ER4P-63N3PB  
ER4P-63N6SB  
ER4P-80N3PB  
ER4P-80N6SB  
4X 304 stainless  
ER4X-16N3PB  
ER4X-16N6SB  
ER4X-25N3PB  
ER4X-25N6SB  
ER4X-40N3PB  
ER4X-40N6SB  
ER4X-63N3PB  
ER4X-63N6SB  
ER4X-80N3PB  
ER4X-80N6SB  
12  
3
6
3
6
3
6
3
6
3
6
ER1-16N3PB  
ER1-16N6SB  
ER1-25N3PB  
ER1-25N6SB  
ER1-40N3PB  
ER1-40N6SB  
ER1-63N3PB  
ER1-63N6SB  
ER1-80N3PB  
ER1-80N6SB  
ER3R-16N3PB  
ER3R-16N6SB  
ER3R-25N3PB  
ER3R-25N6SB  
ER3R-40N3PB  
ER3R-40N6SB  
ER3R-63N3PB  
ER3R-63N6SB  
ER3R-80N3PB  
ER3R-80N6SB  
ER4-16N3PB  
ER4-16N6SB  
ER4-25N3PB  
ER4-25N6SB  
ER4-40N3PB  
ER4-40N6SB  
ER4-63N3PB  
ER4-63N6SB  
ER4-80N3PB  
ER4-80N6SB  
ER12-16N3PB  
ER12-16N6SB  
ER12-25N3PB  
ER12-25N6SB  
ER12-40N3PB  
ER12-40N6SB  
ER12-63N3PB  
ER12-63N6SB  
ER12-80N3PB  
ER12-80N6SB  
16  
25  
40  
63  
80  
1 Polycarbonate enclosure flammability rating UL 94-5V A-V0.  
Switch ratings  
For wire types, ranges and terminal torques, see table on page 11-80.  
Amps  
16  
25  
40  
63  
Switch catalog no.  
RD16-3-508  
Vac  
SCCR with max upstream Class J fuse  
Max. Hp @ 600 V  
10  
20  
25  
40  
40  
65 kA /30 A  
RD25-3-508  
RD40-3-508  
RD63-3-508  
RD80-3-508  
600  
65 kA /30 A — 10 kA / 60 A  
65 kA /60 A — 50 kA / 100 A  
50 kA / 100 A  
80  
Note: Voltage, SCCR and horsepower ratings are the same for 3- and 6-pole switches.  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
11-89  
Eaton.com/bussmannseries  
11 — Disconnect switches  
UL 508 enclosed non-fused disconnect — 16 to 80 A  
W
Enclosure weights and dimensions  
Mounting centers h x w (in)  
NEMA  
Switch  
amps  
MH H  
enclosure  
Poles  
H x W x D (in)  
8x6x6  
A
6.3x4.3  
8.3x6.3  
B
C
Weight (lbs)  
A
3
6
3
6
3
8
11  
8
11  
4
1, 3R, 4, 12  
4X-304 SST  
10x8x6  
8x6x6  
10x8x6  
16-80  
8.7x4.3  
10.7x6.3  
8x3.6  
10x3.6  
12x5.6  
6.3x6.7  
8.3x8.7  
3.6x8  
5.6x8  
7.6x10  
MW  
W
16-63  
80  
16-8 A  
7.4x8.7x5.8  
9.4x8.7x5.9  
11.4x10.7x6.3  
4X-plastic 1  
5
6
6
1 Polycarbonate.  
H
MH  
Available field-installed accessories - order separately  
Auxiliary contacts  
B
Cont.  
MW  
W
No. of  
amp  
Contact type contacts rating  
Vac  
Max. units per switch  
Catalog no.  
BAC01  
BAC02  
NO + NC  
NO  
1 Ea.  
2
10  
240  
2 (1 per side, 4 contacts total)  
Auxiliary contact  
configurations  
H
MH  
C
Terminal shrouds  
Includes terminal shroud for both lineside and loadside.  
MW  
Switch amps  
16-40  
Poles  
Location on switch  
Lineside and loadside  
Catalog no.  
TSH1-3TB  
TSH2-3TB  
3
63-80  
Switched 4th pole  
Converts 3-pole switch to 4-pole switch.  
Switch amps  
Catalog no.  
POLE-16  
16  
25  
40  
POLE-25  
POLE-40  
11-90  
BUSSMANN SERIES FULL LINE CATALOG 1007 — OCTOBER 2018  
Eaton.com/bussmannseries  

相关型号:

ER3R-63N3PR

SWITCH COMP HANDLE RED/YELLOW
ETC

ER3R-63N6SB

SWITCH COMPONENT HANDLE BLACK
ETC

ER3R-80N3PB

SWITCH COMPONENT HANDLE BLACK
ETC

ER4-1200N3PR

SWITCH COMP HANDLE RED/YELLOW
ETC

ER4-30J3PB

SWITCH COMPONENT HANDLE BLACK
ETC

ER4-30N3PB

SWITCH COMPONENT HANDLE BLACK
ETC

ER4-30N3PR

SWITCH COMP HANDLE RED/YELLOW
ETC

ER4-40N3PB

SWITCH COMPONENT HANDLE BLACK
ETC

ER4-600N3PB

SWITCH COMPONENT HANDLE BLACK
ETC

ER4-63N3PB

SWITCH COMPONENT HANDLE BLACK
ETC

ER4-800N3PB

SWITCH COMPONENT HANDLE BLACK
ETC

ER4-80N6SB

SWITCH COMPONENT HANDLE BLACK
ETC