Through-beam
Type ET 1820 DC, Nickel-plated Brass Housing
• Range: 20 m
• Adjustable sensitivity
• Modulated infrared light
• Make and break switching functions,
NPN, PNP (200 mA)
• LED-indication for power supply ON (emitter) and
target detected (receiver)
• Supply voltage: 10 to 40 VDC
• Heavy duty M18 metal housing, IP 67
• Cable and plug versions
Product Description
Ordering Key
Type
Housing diameter
Range
Output type
Housing material
Connection type
ET 18 20 NPA S-1
The ET1820 is a family of gen- sensing performance. The sen-
eral purpose through-beam sors are easy to adjust with a
sensors in an industrial stan- 270° single turn potentiometer.
dard M18 nickel-plated brass The output is a 4-wire comple-
housing for heavy duty appli- mentary (NO and NC) circuit
cations. They are useful for with NPN (current sinking) or
simple applications where a PNP (current sourcing) open
basic sensor provide adequate collector transistor output.
Type Selection
Housing
diameter
Rated
operating
dist. (Sn)
Connection
Ordering no.
Ordering no.
Ordering no.
Emitter
Receiver/NPN
Receiver/PNP
Make & break switching
Make & break switching
M18
M18
20 m
20 m
Cable
Plug
ET 1820 NPAS
ET 1820 NPAS-1
ET 1820 PPAS
ET 1820 PPAS-1
ET 1820
ET 1820-1
Note: Please order emitter and receiver separately.
Specifications Receiver
Specifications Emitter
Rated operating dist. (Sn)
Sensitivity
Up to 10 m
Rated operational volt. (UB)
10 to 40 VDC
(ripple included)
270° single turn pot. meter
0.6%/°C
Ripple (Urpp
)
≤ 10%
Temperature drift
Supply current (Io)
Protection
≤ 20 mA
Hysteresis (H) (Differential travel) 3 to 20%
Rated operational volt. (UB) 10 to 40 VDC (ripple included)
Ripple (Urpp
Reverse polarity,
short-circuits, transients
)
Max. 10%
Light source
Light type
Optical angle
Indication
Supply ON
GaAIAs LED, 880 nm
Infrared, modulated
No-load supply current (Io)
Min. operational current (Ie)
OFF-state current (Ir)
Max. 12 mA (typ. 8 mA)
0.5 mA
2°
Max. 100 µA (typ. 0)
LED, green
Output current
Continuous (Ie)
Short-time (I)
Max. 200 mA
200 mA
Max. load capacity 100 nF
Voltage drop (Ud)
Max. 2.5 VDC
Protection
Reverse polarity,
short-circuit, transients
Optical angle
Ambient light
2°
Max. 5,000 lux
Operating frequency (f)
Typ. 170 Hz
Response time
OFF-ON (tON
)
Typ. 1.6 ms
Typ. 4.2 ms
ON-OFF (tOFF
)
Specifications are subject to change without notice (14.03.2006)
1
ET 1820 DC
General Specifications
Power ON delay (tv)
70 ms
Housing material
Body
Front
Cable end
Nuts
Nickel plated brass
PC, black
Polyester, black
Nickel plated brass
Indication
Light and dark
(Complementary switch)
LED, yellow
Output ON
Environment
Overvoltage category
Pollution degree
Connection
Cable
III (IEC 60664/664A; 60947-1)
3 (IEC 60664/664A; 60947-1)
IP 67 (IEC 60529; 60947-1)
Grey, 2 m oilproof, PVC,
Receiver 4 x 0.34 mm2, ø 5.2 mm
Ermitter 2 x 0.5 mm2, ø 5.2 mm
M12 x 1
Degree of protection
Temperature
Operating
Storage
Plug
-20° to +60°C (-4° to +140°F)
-30° to +70°C (-22° to +158°F)
Cables for plug (M1)
CON.1A-..series
Weight
Cable version
Plug version
Vibration
10 to 150 Hz, 0.5 mm/7.5 g
(IEC 60068-2-6)
2 x 1 m & 100 x0.5 m
(IEC 60068-2-32)
137 g
54 g
Shock
Approvals
CE-marking
UL, CSA
Yes
Dielectric voltage
500 VAC
(IEC 60364-4-41)
Operation Diagram
Power supply
Object present, light beam interrupted
Output ON: Break switching (NC)
Tv
Tv
Make switching (NO)
Dimensions
Wiring Diagrams
+
-
+
1 BN
4 BK
2 WH
1 BN
2 WH
4 BK
3 BU
3 BU
-
NPN
PNP
10 - 40 VDC
+
BN
BU
-
Emitter
2
Specifications are subject to change without notice (14.03.2006)
ET 1820 DC
Detection Diagram
Delivery Contents
• Photoelectric switch: ET 1820
• 2 nuts
Emitter
Y
X
(feet)
• Packaging: Plastic bag
Receiver
6.6
13
20
26
33
39
46
8
20.0
10.0
0.0
Accessories
• MB18A
• Connector type CON.1A../CON.14NF.. series
• APA18-RAR
• APA18-AR
4
0
-4
-8
-10.0
-20.0
For further information refer to “Accessories”.
0.0
2.0
4.0
6.0
8.0
10.0
12.0
14.0
Distance (m)
Installation Hints
To avoid interference from inductive voltage/
current peaks, separate the prox. switch pow-
er cables from any other power cables, e.g.
motor, contactor or solenoid cables
Relief of cable strain
Protection of the sensing face
Switch mounted on mobile carrier
Incorrect
Correct
The cable should not be pulled
Any repetitive flexing of the
cable should be avoided
A proximity switch should not serve as
mechanical stop
Specifications are subject to change without notice (14.03.2006)