FD-F41 概述
Digital Fiber Sensor FX-100 SERIES
FD-F41 数据手册
通过下载FD-F41数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。
PDF下载Digital Fiber Sensor
123
FX-100 SERIES
■General terms and conditions............. P.1
■
■
Sensor selection guide........P.11~ / P.61~
Fiber selection................................. P.63~
FIBER
Related Information
SENSORS
■
Glossary of terms / General precautions...P.983~ / P.986~
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Conforming to
EMC Directive
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
PNP output
Timer
Interference Light intensity
prevention
monitor
type available
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
SUNX website http://www.sunx.com
Automatic
Test input
sensitivity setting
STATIC CONTROL
DEVICES
LASER
MARKERS
Taking fiber sensors to the next level
Setup is made simple, using a dual digital display
The dual digital display allows users to check both the threshold
value and incident light intensity at the same time, allowing
for clear and intuitive control of the sensor’s functions. The
Selection
Guide
threshold value can be adjusted simply by pressing the
(UP)
key or the (DOWN) key, so that the output operation can be
controlled with high precision, directly from the RUN mode.
Fibers
Threshold value Incident light intensity
FT / FD / FR
Fiber Sensor
Amplifiers
Commercially-available connectors are used so that lead time and spare part numbers
can both be reduced
FX-100
FX-300
The connectors used are commercially-available connectors,
so that processing costs and lead time required for carrying
out processing after purchase of the sensors can be greatly
reduced. The same connection parts as the DP-100 series
of digital pressure sensors and the PM-64 series of micro
photoelectric sensors can be used.
Connection with a
FX-410
commercially-available
FX-311
connector
FX-11A
FX-301-F
Other
Products
Commercially-available press-fit connectors are used, so that the processing
costs for connection cables can be greatly reduced.
Conventional lead time
Conventional (cable type)
●
Harness processing by outside order after sensor preparation
Customer
Sensor preparation
Sensor installation
1 Sensor purchase and preparation
Harness
Harness Processing
2 Harness processing by outside order processor
Lead time from now on
From now on (built-in connector type)
●
Harness processing by outside order
Customer
Sensor preparation
Sensor installation
Reduced
Harness
processor
1 Sensor purchase and preparation
2 Harness processing by outside order
Harness Processing
Lead time further reduced
Using cables with connectors
Reduced
lead time
Customer
Sensor preparation
Sensor installation
Reduced
1
Purchase of sensors and cable with connectors
Digital Fiber Sensor FX-100SERIES
124
ORDER GUIDE
P.126~
LIST OF FIBERS
P.128~
SPECIFICATIONS I/O CIRCUIT DIAGRAMS SENSING CHARACTERISTICS
PRECAUTIONS FOR PROPER USE
DIMENSIONS
P.133
P.134~
P.135~
P.136~
P.138
Saving-space with a width of 9 mm 0.354 in Equipped with a four-chemical emitting element
FIBER
SENSORS
The sensor is very slim, yet equipped with a dual digital
display. Both space saving and ease of use have been
achieved.
A stable amount of emitted light is ensured due to control
of the aging of the emitting element to the maximum limit.
LASER
SENSORS
[Stable sensing comparison]
PHOTOELECTRIC
SENSORS
FX-100
Three-chemical
MICRO
emitting element
PHOTOELECTRIC
SENSORS
9 mm
0.354 in
AREA
Long-term
stability
SENSORS
SAFETY
Time
COMPONENTS
A three level navigation structure provides easy access to the sensor’s functions, from
basic to advanced
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Setting details are divided into three levels for simple operation, so that settings for normal operation are made in
“RUN mode”, basic settings are made in “SET mode”, and advanced functions are set in “PRO mode”. This makes
configuration much easier to understand and carry out.
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
RUN mode
Functions used during normal operation
WIRE-SAVING
SYSTEMS
[Function table]
RUN MODE
•
Changing threshold values • Key lock
MEASUREMENT
SENSORS
• Quick settings • Code settings
Simple setting
SET mode
STATIC CONTROL
DEVICES
Functions used when initializing the
sensor and carrying out maintenance
LASER
MARKERS
[Function table]
• Teaching • L-ON / D-ON setting
• Timer setting
SET MODE
• Attenuation function
• Interference prevention function
PRO mode
Equipped with a full complement
of digital fiber sensor functions
[Function table]
PRO MODE
• Shift • External input • Reset
• GETA • ECO • Display reversing
• Surplus value display • Copy
Selection
Guide
Special and detailed setting
Fibers
•
Threshold tracking
FT / FD / FR
Fiber sensor
Quick setting numbers (summary)
Quick code input function [RUN mode]
Amplifiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Output
operation
Light-emitting
amount selection
Sensor settings can be made simply by selecting preset
values.
No.
Timer
Dark-ON
Dark-ON
Dark-ON
Dark-ON
Light-ON
Light-ON
Light-ON
Light-ON
OFF
ON
None
None
OFF
ON
OFF-delay 10 ms
OFF-delay 10 ms
ON-delay 40 ms
ON-delay 40 ms
ON-delay 10 ms
ON-delay 10 ms
Other
ON
Products
OFF
ON
OFF
Smooth support via telephone [RUN mode]
Confirmation can be carried out smoothly via telephone
by simply quoting numbers. This can be of great
assistance when dealing with foreign country customers.
Digital Fiber Sensor FX-100SERIES
125
Teaching using ON / OFF buttons [SET mode] Attenuation function [SET mode]
FIBER
SENSORS
Simply press the ON button when an object is present
and OFF when it is not. There is no need to switch
If the light receiving level becomes saturated when
sensing over short distances or when sensing
transparent objects or minute objects, the light emitting
amount can be reduced so that stable sensing can be
provided without needing to change the response time.
LASER
SENSORS
settings or make judgments between Light-ON (
and Dark-ON ( ).
)
PHOTOELECTRIC
SENSORS
<Setting example>
Thru-beam type / Retroreflective type
MICRO
PHOTOELECTRIC
SENSORS
Interference prevention function [SET mode]
AREA
SENSORS
FX-101□: Interference prevention for up to 3 units
FX-102□: Interference prevention for up to 4 units
SAFETY
COMPONENTS
The emission frequencies can be set separately for
each unit in order to avoid interference. The emitted light
flashes while setting is in progress, so that you can see
at a glance which fiber sensor is currently being set.
In addition, this interference prevention is not done by
using optical communication. This means that there is no
need to place the amplifiers close together like there was
before, and so the amplifiers can be set up apart from
each other.
Object present ON
Object absent OFF
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
Reflective type
USE SENSORS
SENSOR
OPTIONS
* When the emission frequencies are changed, the response times will
also change.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Object present ON
Object absent OFF
STATIC CONTROL
DEVICES
LASER
MARKERS
The emitted light and output indicator flash
at the same frequency.
Limit teaching function
This carries out teaching and sets threshold values only
when no object is present (when the incident light amount
is stable). This is useful when sensing objects if there
are other objects in the background and when sensing
minute objects. Teaching can also be carried out using
external input.
Multi-function external input [PRO mode]
(Brown) +V
Settings such as emission
halt, limit / auto teaching
and ECO settings can be
carried out via external
input.
(Black) Output
(White) External input
(Blue) 0 V
Selection
Guide
Threshold tracking function [PRO mode]
Fibers
External input lines are
equipped as standard
This function seeks changes
in the light emitting amount
resulting from changes in
the environment over long
periods (such as dust levels),
so that the incident light
intensity can be checked
at desired intervals and the
threshold values can be reset
automatically.
Current value
The amount of light
received when there
is no object
FT / FD / FR
Fiber Sensor
Amplifiers
Alert function [PRO mode]
FX-100
FX-300
When the amount light received approaches the
threshold value, the display can be made to blink in
order to alert the operator.
Threshold value
FX-410
FX-311
Time
<When using at a shift amount of 20% and a threshold value of 1,000>
The amount of light received ranges from about 900 to 1,100
when the digital indicator flashes.
FX-11A
FX-301-F
GETA function [PRO mode]
Other
Products
The display value for the incident light intensity can be offset
by the desired value (target value). The target value can be set
to between 0 and 2,000 (in increments of 100). For example, if
the incident light intensity is 1,500 and the target value is set to
2,000, then “2,000” will appear in the digital display.
Range of the digital indicator flashing
(margin: small)
1,100 approx.
Threshold value
of 1,000
900 approx.
Variations in the amount of light received
The digital indicator flashes.
Unify at 500 using
the GETA function
Digital Fiber Sensor FX-100SERIES
126
ORDER GUIDE
FIBER
SENSORS
Amplifiers
LASER
SENSORS
Accessory
• CN-14A-C2
Emitting
element
PHOTO-
Type
Appearance
Model No.
Output
ELECTRIC
SENSORS
Connector attached
cable 2 m 6.562 ft
MICRO
NPN open-collector
transistor
PHOTO-
ELECTRIC
SENSORS
FX-101 (Note 2)
FX-101-Z (Note 3)
FX-101P (Note 2)
FX-101P-Z (Note 3)
FX-101-CC2
* Only include cable set type
NPN open-collector
transistor
AREA
SENSORS
PNP open-collector
transistor
SAFETY
COMPONENTS
PNP open-collector
transistor
PRESSURE
SENSORS
NPN open-collector
transistor
INDUCTIVE
PROXIMITY
SENSORS
PNP open-collector
collector transistor
FX-101P-CC2
PARTICULAR
USE
Red LED
SENSORS
NPN open-collector
transistor
FX-102 (Note 2)
FX-102-Z (Note 3)
FX-102P (Note 2)
FX-102P-Z (Note 3)
FX-102-CC2
SENSOR
OPTIONS
NPN open-collector
transistor
WIRE-
SAVING
SYSTEMS
PNP open-collector
transistor
MEASURE-
MENT
PNP open-collector
transistor
SENSORS
STATIC
CONTROL
DEVICES
NPN open-collector
transistor
LASER
PNP open-collector
transistor
MARKERS
FX-102P-CC2
Notes: 1) The connector attached cable CN-14A-C2 is supplied with the amplifier.
2) Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg. Co., Ltd.
(contact: SPHD-001T-P0.5, housing: PAP-04V-S)
3) Make sure to use the optional M8 connector attached cable CN-24A-C□.
OPTIONS
M8 connector attached cable
Selection
Guide
Designation
Model No.
Description
• CN-24A-C□
Fibers
31.4
ø4
1 m 3.281 ft
2 m 6.562 ft
3 m 9.843 ft
5 m 16.404 ft
1 m 3.281 ft
2 m 6.562 ft
3 m 9.843 ft
5 m 16.404 ft
2 m 6.562 ft
5 m 16.404 ft
CN-14A-C1
CN-14A-C2 (Note)
CN-14A-C3
CN-14A-C5
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
CN-24A-C2
CN-24A-C5
CN-14A
1.236
ø0.157
FT / FD / FR
Connector
attached cable
Fiber Sensor
Amplifiers
M8 connector
attached cable
CN-24A-C
ø9
0.02 mm2 4-core cabtyre cable with connector
on one end
Cable outer diameter: ø3.7 mm ø0.146 in
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
ø0.354
□
Connector
attached cable
(Flexible type)
Fixing ring
For M8 plug-in connector type
The connector on one end
Cable outer diameter: ø4 mm ø0.157 in
M8 connector
attached cable
Protection cover
• FC-FX-1
Other
Products
Connector
Set of 10 housings and 40 contacts
This protects the operating surfaces.
Protection cover
FC-FX-1
Amplifier
mounting bracket
Mounting bracket for amplifier
MS-DIN-4
MS-DIN-E
When it moves depending on the way it is installed on a DIN rail,
these end plates ensure that all amplifiers are mounted together
in a secure and fully connected manner.
End plates
Two pcs.per set
Amplifier mounting
bracket
Note: The connector attached cable CN-14A-C2 is supplied with the cable set type FX-10□(P)-CC2.
• MS-DIN-4
Recommended connector
Connector
attached cable
Connector
• CN-14A
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the recommended products.
• CN-14A(-R)-C□
Contact
Recommended crimping tool
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Housing
Note: Contact the manufacturer for details of the recommended products.
Digital Fiber Sensor FX-100SERIES
127
LIST OF FIBERS
FIBER
SENSORS
LASER
Thru-beam type (one pair set)
SENSORS
PHOTO-
ELECTRIC
SENSORS
Fibers are listed in alphabetic order. Refer to p.63~ “Fiber Selection” for details of each fiber.
MICRO
Sensing range (mm in) (Note 1)
Standard type FX-101□ Long sensing range type FX-102□
1,500 59.055 3,500 137.795 (Note 2)
Sensing range (mm in) (Note 1)
PHOTO-
Model No.
FT-A8
Dimensions
Model No.
Dimensions
ELECTRIC
SENSORS
Standard type FX-101□ Long sensing range type FX-102□
AREA
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.106
P.107
P.107
P.107
P.107
P.107
P.107
P.107
P.107
P.107
P.107
P.107
P.108
P.108
P.108
P.108
P.108
P.108
P.108
P.108
P.108
P.108
P.108
P.108
40 1.575
180 7.087
300 11.811
760 29.921
180 7.087
130 5.118
300 11.811
1,000 39.370
140 5.512
40 1.575
90 3.543
430 16.929
800 31.496
2,400 94.488
470 18.504
280 11.024
800 31.496
2,350 92.520
380 14.961
120 4.724
P.109
P.109
P.109
P.109
P.109
P.109
P.109
P.109
P.109
P.109
P.109
P.109
P.110
P.110
P.110
P.110
P.110
P.110
P.110
P.110
P.110
P.110
P.110
P.110
P.111
P.111
P.111
P.111
P.111
P.111
P.111
P.111
P.111
P.111
FT-PS1
SENSORS
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
FT-A30
FT-R80
SAFETY
COMPONENTS
280 11.024
240 9.449
400 15.748
6 0.236
720 28.346
670 26.378
1,150 45.276
19 0.748
FT-AFM2
FT-SFM2
FT-SFM2L
FT-SFM2SV2
FT-SNFM2
FT-T80
FT-AFM2E
FT-B8
PRESSURE
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
FT-E12
15 0.591
60 2.362
FT-E22
PARTICULAR
USE
SENSORS
FT-FM2
FT-V10
SENSOR
OPTIONS
300 11.811
800 31.496
FT-FM2S
FT-V22
FT-FM2S4
FT-FM10L
FT-H13-FM2
FT-H20-J20-S (Note 3)
FT-H20-J30-S (Note 3)
FT-H20-J50-S (Note 3)
FT-H20-M1
FT-H20-VJ50-S (Note 3)
FT-H20-VJ80-S (Note 3)
FT-H20W-M1
FT-H30-M1V-S (Note 4)
FT-H35-M2
FT-H35-M2S6
FT-HL80Y
FT-K8
FT-V41
WIRE-
SAVING
9,300 366.141
250 9.843
15,000 590.550
700 27.559
340 13.386
80 3.150
800 31.496
220 8.661
FT-V80Y
FT-W4
SYSTEMS
MEASURE-
MENT
SENSORS
260 10.236
650 25.591
FT-W8
STATIC
CONTROL
DEVICES
135 5.315
420 16.535
1,500 59.055 3,500 137.795 (Note 2)
FT-WA8
FT-WA30
FT-WKV8
FT-WR80
FT-WR80L
FT-WS3
FT-WS4
FT-WS8
FT-WS8L
FT-WV42
FT-WZ4
FT-WZ4HB
FT-WZ7
FT-WZ7HB
FT-WZ8
FT-WZ8E
FT-WZ8H
FT-Z8
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
LASER
MARKERS
210 8.268
150 5.906
540 21.260
500 19.685
700 27.559
215 8.465
430 16.929
150 5.906
80 3.150
2,200 86.614
570 22.441
1,150 45.276
600 23.622
220 8.661
100 3.937
110 4.331
300 11.811
280 11.024
260 10.236
600 23.622
30 1.181
650 25.591
1,500 59.055
80 3.150
170 6.693
490 19.291
Selection
Guide
990 38.976
1,000 39.370
135 5.315
2,340 92.126
3,000 118.110
500 19.685
Fibers
230 9.055
80 3.150
670 26.378
230 9.055
FT / FD / FR
FT-KV1
Fiber sensor
Ampilifiers
1,000 39.370
1,100 43.307
3,000 118.110
2,600 102.362
330 12.992
190 7.480
330 12.992
700 27.559
1,200 47.244
360 14.173
800 31.496
1,400 55.118
520 20.472
1,000 39.370
580 22.835
950 37.402
2,100 82.677
2,800 110.236
1,000 39.370
1,850 72.835
3,100 122.047
3,100 122.047
FT-KV8
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
FT-L80Y
FT-NFM2
130 5.118
280 11.024
FT-NFM2S
FT-NFM2S4
FT-P2
120 4.724
80 3.150
330 12.992
240 9.449
300 11.811
650 25.591
800 31.496
FT-P40
FT-Z8E
Other
Products
130 5.118
230 9.055
260 10.236
FT-P60
FT-Z8H
FT-P80
FT-Z802Y
FT-P81X
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
2) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long.
3) Heat-resistant joint fibers and ordinary-temperature side fibers (FT-FM2) are sold as a set. Please refer to p.93~ for details.
4) Sold as a set comprising vacuum-resistant type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Please refer to p.91~ for details.
Digital Fiber Sensor FX-100SERIES
128
LIST OF FIBERS
FIBER
SENSORS
LASER
SENSORS
Retroreflective type
PHOTO-
ELECTRIC
SENSORS
Fibers are listed in alphabetic order. Refer to p.63~ “Fiber Selection” for details of each fiber.
MICRO
Sensing range (mm in) (Note 1, 2)
PHOTO-
ELECTRIC
SENSORS
Model No.
Dimensions
Standard type FX-101□
15 to 200 0.591 to 7.874
200 7.874
Long sensing range type FX-102□
15 to 360 0.591 to 14.173
200 7.874
AREA
P.112
P.112
P.112
P.112
FR-KV1
SENSORS
FR-KZ21
FR-KZ21E
FR-WKZ11
SAFETY
COMPONENTS
200 7.874
200 7.874
PRESSURE
SENSORS
100 to 550 3.937 to 21.654
100 to 830 3.937 to 32.677
Notes: 1) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
The sensing range of FR-WKZ11 is specified for the RF-13. The sensing range of FR-KZ21, FR-KZ21E and FR-KV1 is specified for the attached reflector.
The sensing ranges when using in combination with the FR-WKZ11 reflector (optional) are given in the below table.
INDUCTIVE
PROXIMITY
SENSORS
Amplifier
PARTICULAR
USE
FX-101□
FX-102□
Reflector
SENSORS
100 to 700 3.937 to 27.559
100 to 1,100 3.937 to 43.307
FR-WKZ11 + RF-210
SENSOR
OPTIONS
100 to 1,300 3.937 to 51.181 100 to 2,600 3.937 to 102.362
100 to 2,000 3.937 to 78.740 100 to 4,000 3.937 to 157.480
FR-WKZ11 + RF-220
FR-WKZ11 + RF-230
WIRE-
SAVING
SYSTEMS
2) The sensing range of FR-WKZ11 is the possible setting range for the reflector or reflective tape. The fiber can detect an object less than 100 mm 3.937 in away.
However, note that if there are any white or highly-reflective surfaces near the fiber head, reflected incident light may affect the fiber head. If this occurs,
adjust the threshold value of the amplifier unit before use.
The sensing range of FR-KZ21(E) is the possible setting range for the reflector. However, if setting the fiber to detect objects passing within 0 to 20 mm
0 to 0.787 in from the fiber head, unstable detection may result.
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
The sensing range of FR-KV1 is the possible setting range for the reflector. The fiber can detect an object less than 15 mm 0.591 in away.
LASER
MARKERS
Reflective type
Fibers are listed in alphabetic order. Refer to “Fiber Selection p.63~” for details of each fiber.
Sensing range (mm in) (Note 1, 2)
Sensing range (mm in) (Note 1, 2)
Model No.
Dimensions
Model No.
FD-G6
Dimensions
Standard type FX-101□ Long sensing range type FX-102□
Standard type FX-101□ Long sensing range type FX-102□
125 4.921
105 4.134
85 3.346
250 9.843
285 11.220
245 9.646
440 17.323
13 0.512
45 1.772
50 1.969
30 1.181
22 0.866
4 0.157
P.113
P.113
P.113
P.113
P.113
P.113
P.113
P.113
P.113
P.113
P.114
50 1.969
45 1.772
120 4.724
160 6.299
P.114
P.114
P.114
P.115
P.115
P.115
P.115
P.115
P.115
P.116
P.116
P.116
FD-A15
FD-AFM2
FD-AFM2E
FD-B8
FD-G6X
100 3.937
280 11.024
FD-H13-FM2
FD-H18-L31
FD-H20-21
Selection
Guide
170 6.693
3.5 0.138
0 to 10 0 to 0.394
90 3.543
0 to 25 0 to 0.984
280 11.024
Fibers
FD-E12
FT / FD / FR
16 0.630
120 4.724
300 11.811
Fiber Sensor
FD-E22
FD-H20-M1
Amplifiers
18 0.709
25 to 80 0.984 to 3.150 10 to 220 0.394 to 8.661
FD-EG1
FD-H30-KZ1V-S (Note 3)
FD-H30-L32
FD-H30-L32V-S (Note 3)
FD-H35-20S
FD-H35-M2
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
10 0.394
2 to 9 0.079 to 0.354
2.5 to 6.5 0.098 to 0.256
85 3.346
0 to 17 0 to 0.669
0 to 11 0 to 0.433
200 7.874
FD-EG2
7 0.276
FD-EG3
1 0.039
FD-EN500S1
FD-ENM1S1
15 0.591
48 1.890
75 2.953
280 11.024
Applicable pipe diameter:
FD-H35-M2S6
Outer dia. ø6 to ø26 mm ø0.236 to
ø1.024 in transparent pipe
[PFA (fluorine resin) or equivalently
transparent pipe, wall thickness 1 mm
0.039 in]
5 to 8 0.197 to 0.315 1 to 17 0.039 to 0.669
(Convergent point 6 0.236) (Convergent point 6 0.236)
Other
P.116
P.116
FD-L4
P.114
P.114
FD-F4
Products
3 to 14 0.118 to 0.551 1.5 to 16 0.059 to 0.630
(Convergent point 8 0.315) (Convergent point 8 0.315)
FD-L41
0 to 19 0 to 0.748
0 to 6 0 to 0.236
0 to 25 0 to 0.984
0 to 8 0 to 0.315
P.116
P.116
P.116
P.116
P.116
P.117
P.117
P.117
P.117
FD-L43
Applicable pipe diameter:
Outer dia. ø6 to ø26 mm ø0.236 to
ø1.024 in transparent pipe
[PVC (vinyl chloride), fluorine resin,
polycarbonate, acrylic, glass, wall
thickness 1 to 3 mm 0.039 to 0.118 in]
FD-L44
FD-F41
0 to 4.5 0 to 0.177 0 to 5.5 0 to 0.217
0 to 40 0 to 1.575 0 to 50 0 to 1.969
FD-L44S
FD-L45
P.114
P.114
P.114
P.114
P.114
16 to 30 0.630 to 1.181 12 to 50 0.472 to 1.969
FD-F8Y
FD-L46
100 3.937
100 3.937
50 1.969
410 16.142
345 13.583
120 4.724
FD-FM2
FD-FM2S
FD-FM2S4
FD-G4
FD-NFM2
FD-NFM2S
FD-NFM2S4
FD-P2
35 1.378
25 0.984
100 3.937
65 2.559
Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. Refer to p.71~ for details.
2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
3) Sold as a set comprising vacuum-resistant type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Please refer to p.91~ for details.
Digital Fiber Sensor FX-100SERIES
129
LIST OF FIBERS
FIBER
SENSORS
LASER
Reflective type
SENSORS
PHOTO-
ELECTRIC
SENSORS
Fibers are listed in alphabetic order. Refer to “Fiber Selection p.63~” for details of each fiber.
MICRO
Sensing range (mm in) (Note 1, 2)
Sensing range (mm in) (Note 1, 2)
PHOTO-
Model No.
Dimensions
Model No.
Dimensions
ELECTRIC
SENSORS
Standard type FX-101□ Long sensing range type FX-102□
Standard type FX-101□ Long sensing range type FX-102□
AREA
8 0.315
45 1.772
45 1.772
90 3.543
70 2.756
70 2.756
100 3.937
30 1.181
35 1.378
35 1.378
100 3.937
25 0.984
80 3.150
15 0.591
30 1.181
150 5.906
150 5.906
200 7.874
220 8.661
180 7.087
345 13.583
90 3.543
P.117
P.117
P.117
P.117
P.117
P.117
P.117
P.117
P.118
P.118
P.118
P.118
P.118
P.118
28 1.102
75 2.953
P.118
P.118
FD-P40
FD-WG4
SENSORS
20 to 180 0.787 to 7.087 20 to 480 0.787 to 18.898
FD-P50
FD-WKZ1
SAFETY
COMPONENTS
7 to 12 0.276 to 0.472 6 to 13.5 0.236 to 0.531
(Convergent point 8 0.315) (Convergent point 8 0.315)
FD-P60
P.118
FD-WL41
PRESSURE
SENSORS
FD-P80
1 to 4.5 0.039 to 0.177 0.5 to 6.5 0.020 to 0.256
P.119
P.119
P.119
P.119
P.119
P.119
P.119
P.119
P.119
P.119
FD-WL48
FD-WS8
FD-P81X
FD-R80
FD-S80
80 3.150
28 1.102
15 0.591
80 3.150
6 0.236
230 9.055
75 2.953
40 1.575
230 9.055
20 0.787
INDUCTIVE
PROXIMITY
SENSORS
FD-WSG4
FD-WT4
PARTICULAR
USE
SENSORS
FD-SFM2SV2
FD-SNFM2
FD-T40
FD-WT8
SENSOR
OPTIONS
100 3.937
100 3.937
345 13.583
70 2.756
FD-WV42
FD-WZ4
WIRE-
SAVING
2 to 20 0.079 to 0.787 1 to 70 0.039 to 2.756
SYSTEMS
FD-T80
FD-WZ4HB
FD-WZ7
MEASURE-
MENT
FD-V41
1 to 55 0.039 to 2.165
160 6.299
SENSORS
230 9.055
40 1.575
FD-W8
1 to 60 0.039 to 2.362 0.5 to 180 0.020 to 7.087
FD-WZ7HB
STATIC
CONTROL
DEVICES
FD-W44
Notes: 1) The standard sensing objects of the sensing ranges vary depending on the fibers. Refer to p.71~ for details.
LASER
2) Please take care that the sensing range of the free-cut type fiber may be reduced by 20 % max. depending upon how the fiber is cut.
MARKERS
3) Sold as a set comprising vacuum-resistant type fiber + photo-terminal (FV-BR1) + fiber at atmospheric side (FT-J8). Please refer to p.91~ for details.
Selection
Guide
Fibers
FT / FD / FR
Fiber sensor
Ampilifiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
Digital Fiber Sensor FX-100SERIES
130
FIBER OPTIONS
FIBER
SENSORS
LASER
Lens (For thru-beam type fiber)
The dimensions are on p.120~.
SENSORS
PHOTO-
ELECTRIC
SENSORS
Designation
Model No.
Description
MICRO
PHOTO-
ELECTRIC
SENSORS
Sensing range (mm in) [Lens on both sides]
Amplifier
FX-101□
FX-102□
Fiber
AREA
FT-B8
2,200 86.614
3,000 118.110
1,900 74.803
3,000 118.110
3,500 137.795 (Note 2)
3,500 137.795 (Note 2)
3,500 137.795 (Note 2)
3,500 137.795 (Note 2)
SENSORS
FT-FM2, FT-T80
FT-R80
SAFETY
Increases the sensing
range by 5 times or more.
COMPONENTS
FT-W8
Expansion
lens
(Note 1)
PRESSURE
SENSORS
• Ambient temperature:
60 to +350 °C
76 to +662 °F
FX-LE1
FT-P80, FT-P60
FT-P81X
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
–
–
INDUCTIVE
PROXIMITY
SENSORS
(Note 3)
FT-H35-M2
FT-H20W-M1
FT-H20-M1
2,000 78.740
1,300 51.181
3,500 137.795 (Note 2)
1,600 62.992 (Note 2)
PARTICULAR
USE
1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
SENSORS
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S 1,000 39.370
3,500 137.795 (Note 2)
SENSOR
OPTIONS
Sensing range (mm in) [Lens on both sides]
WIRE-
SAVING
SYSTEMS
Amplifier
FX-101□
FX-102□
Fiber
Tremendously increases the
sensing range with large
diameter lenses.
FT-B8, FT-FM2, FT-R80, FT-W8, FT-P80, FT-P60 3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
MEASURE-
MENT
Super-
expansion
lens
FT-P81X
1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
SENSORS
FX-LE2
• Ambient temperature:
FT-H35-M2
STATIC
–
CONTROL
DEVICES
(Note 1)
60 to +350 °C
FT-H20W-M1, FT-H20-M1 1,600 62.992 (Note 2) 1,600 62.992 (Note 2)
FT-H13-FM2 3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
–
76 to +662 °F
(Note 3)
LASER
MARKERS
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S 3,500 137.795 (Note 2) 3,500 137.795 (Note 2)
Sensing range (mm in) [Lens on both sides]
Amplifier
FX-101□
530 20.866
550 21.654
450 17.717
420 16.535
300 11.811
550 21.654
280 11.024
140 5.512
280 11.024
150 5.906
FX-102□
1,450 57.087
1,700 66.929
1,300 51.181
1,400 55.118
850 33.465
1,700 66.929
800 31.496
400 15.748
840 33.071
410 16.142
Fiber
FT-B8
FT-FM2, FT-T80
FT-W8
Beam axis is bent by 90°.
• Ambient temperature:
60 to +300 °C
76 to +572 °F
FT-P80
Side-view
lens
FX-SV1
–
–
FT-P60
Selection
Guide
FT-P81X
(Note 3)
Fibers
FT-H35-M2
FT-H20W-M1
FT-H20-M1
FT-H20-J20-S, FT-H20-J30-S, FT-H20-J50-S
FT / FD / FR
Fiber Sensor
Amplifiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Sensing range increases by
4 times or more.
Sensing range (mm in) [Lens on both sides] (Note 4)
Amplifier
Expansion
lens for vacuum-
resistant fiber
(Note 1)
FX-101□
FX-102□
• Ambient temperature:
Fiber
FV-LE1
FV-SV2
–
60 to +350 °C –76 to +662 °F
FT-H30-M1V
450 17.717
1,600 62.992
(Note 3)
Sensing range (mm in) [Lens on both sides] (Note 4)
Amplifier
Beam axis is bent by 90°.
Side-view
lens for
vacuum-
FX-101□
FX-102□
Fiber
• Ambient temperature:
Other
–
60 to +300 °C –76 to +572 °F
FT-H30-M1V
450 17.717
1,600 62.992
resistant fiber
Products
(Note 3)
Notes: 1) Be careful when installing the thru-beam type fiber equipped with the expansion lens, as the beam envelope becomes narrow and alignment is difficult.
Especially when installing a fiber with many cores (sharp bending fibers and heat-resistant glass fiber), please be sure to use it only after you have
adjusted it sufficiently.
2) The fiber cable length practically limits the sensing range to 3,500 mm 137.795 in long (FT-H20W-M1, FT-P81X and FT-H20-M1: 1,600 mm 62.992 in).
3) For details on the ambient temperatures for the fibers which being combined, refer to p.101~.
4) The fiber cable length for the FT-H30-M1V is 1 m 3.281 ft. The sensing ranges in FX-102□ (long sensing range type) take into account the length of the
FT-J8 atmospheric side fiber.
Digital Fiber Sensor FX-100SERIES
131
FIBER OPTIONS
FIBER
SENSORS
LASER
Lens (For reflective type fiber)
The dimensions are on p.121~.
SENSORS
PHOTO-
ELECTRIC
SENSORS
Designation
Model No.
Description
MICRO
PHOTO-
ELECTRIC
SENSORS
Pinpoint spot of ø0.5 mm ø0.020 in. Enables detection of minute objects or small marks.
• Distance to focal point: 6 ± 1 mm 0.236 ± 0.039 in • Applicable fibers: FD-WG4, FD-G4
• Ambient temperature: –40 to +70 °C –40 to +158 °F (Note 2)
Pinpoint spot
lens
FX-MR1
AREA
SENSORS
Sensing range for FX-101□ (mm in) (Note 1)
SAFETY
COMPONENTS
Screw-in depth Distance to focal point Spot diameter
18.5 0.728
The spot diameter is adjustable from ø0.7 to
ø2 mm ø0.028 to ø0.079 in according to how
much the fiber is screwed in.
• Applicable fibers: FD-WG4, FD-G4
• Ambient temperature: –40 to +70 °C
–40 to +158 °F (Note 2)
Screw-in
depth
PRESSURE
SENSORS
7 mm 0.276 in
12 mm 0.472 in
14 mm 0.551 in
ø0.7 ø0.028
ø1.2 ø0.047
ø2.0 ø0.079
approx.
Zoom lens
FX-MR2
INDUCTIVE
PROXIMITY
SENSORS
Distance to
focal point
27 1.063
approx.
Spot
diameter
• Accessory: MS-EX-3 (mounting bracket)
43 1.693
approx.
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Sensing range for FX-101□ (mm in) (Note 1)
Fiber model No. Distance to focal point Spot diameter
WIRE-
SAVING
7.5 ± 0.5
0.295 ± 0.020 approx.
ø0.15 ø0.006
Extremely fine spot of ø0.3 mm ø0.012 in
approx. achieved.
• Applicable fibers: FD-WG4, FD-G4, FD-EG1,
FD-EG2, FD-EG3, FD-G6X, FD-G6
• Ambient temperature: –40 to +70 °C
–40 to +158 °F (Note 2)
FD-EG3
FD-EG2
FD-EG1
SYSTEMS
MEASURE-
MENT
Finest spot
lens
7.5 ± 0.5
0.295 ± 0.020 approx.
ø0.2 ø0.008
FX-MR3
SENSORS
STATIC
CONTROL
DEVICES
7.5 ± 0.5
0.295 ± 0.020 approx.
ø0.3 ø0.012
FD-WG4/G4, 7.5 ± 0.5
FD-G6X/G6 0.295 ± 0.020 approx.
ø0.5 ø0.020
LASER
MARKERS
Distance to
focal point
Sensing range for FX-101□ (mm in) (Note 1)
Fiber model No. Distance to focal point Spot diameter
Spot diameter
7 ± 0.5
0.276 ± 0.020 approx.
ø0.1 ø0.004
Extremely fine spot of ø0.1 mm ø0.004 in
approx. achieved.
• Applicable fibers: FD-WG4, FD-G4, FD-EG1,
FD-EG2, FD-EG3, FD-G6X, FD-G6
• Ambient temperature: –20 to +60 °C
–4 to +140 °F (Note 2)
FD-EG3
FD-EG2
FD-EG1
Finest spot
lens
7 ± 0.5
0.276 ± 0.020 approx.
ø0.15 ø0.006
FX-MR6
7 ± 0.5
0.276 ± 0.020 approx.
ø0.2 ø0.008
Selection
Guide
FD-WG4/G4, 7 ± 0.5
ø0.4 ø0.016
FD-G6X/G6 0.276 ± 0.020 approx.
Fibers
FT / FD / FR
Sensing range for FX-101□ (mm in) (Note 1)
Fiber sensor
Ampilifiers
Screw-in
depth
Screw-in depth Distance to focal point Spot diameter
13 0.512
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
FX-MR2 is converted into a side-view type
and can be mounted in a very small space.
• Applicable fibers: FD-WG4, FD-G4
• Ambient temperature: –40 to +70 °C
–40 to +158 °F (Note 2)
8 mm 0.315 in
10 mm 0.394 in
14 mm 0.551 in
ø0.5 ø0.020
ø0.8 ø0.031
ø3.0 ø0.118
Zoom lens
Side-view
type
approx.
FX-MR5
15 0.591
approx.
Distance
to focal
point
30 1.181
approx.
Spot diameter
Notes: 1) The sensing ranges are the values when used in combination with FX-101□ (standard type). Please contact our office for details on sensing ranges for
other types of amplifier.
Other
2) For details on the ambient temperatures for the fibers which being combined, refer to p.101~.
Products
Digital Fiber Sensor FX-100SERIES
132
SPECIFICATIONS
FIBER
Refer to p.101~ for fiber specifications.
SENSORS
LASER
Standard type
Long sensing range type
Cable set
SENSORS
Type
Cable set
FX-101-CC2
FX-101P-CC2
PHOTO-
ELECTRIC
SENSORS
NPN output
FX-101(-Z) (Note 4)
FX-101P(-Z) (Note 4)
FX-102(-Z) (Note 4)
FX-102P(-Z) (Note 4)
FX-102-CC2
MICRO
PHOTO-
ELECTRIC
SENSORS
Item
PNP output
FX-102P-CC2
Supply voltage
12 to 24 V DC ± 10 % Ripple P-P 10 % or less
AREA
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage)
SENSORS
Power consumption
Output
SAFETY
COMPONENTS
<NPN output type>
NPN open-collector transistor
<PNP output type>
PNP open-collector transistor
• Maximum source current: 100 mA
PRESSURE
SENSORS
• Maximum sink current: 100 mA
•
Applied voltage: 30 V DC or less (between output and 0 V)
•
•
Applied voltage: 30 V DC or less (between output and +V)
Residual voltage: 1.5 V or less (at 100 mA source current)
• Residual voltage: 1.5 V or less (at 100 mA sink current)
INDUCTIVE
PROXIMITY
SENSORS
Output operation
Selectable either Light-ON or Dark-ON, at SET mode
Incorporated
PARTICULAR
USE
Short-circuit protection
SENSORS
<NPN output type>
NPN non-contact input
• Signal condition
<PNP output type>
PNP non-contact input
• Signal condition
SENSOR
OPTIONS
External input
Response time
High: +8 V to +V DC or Open
Low: 0 to +2 V DC
(Source current 0.5 mA or less)
• Input impedance: 10 kΩ approx.
High: +4 V to +V DC
WIRE-
SAVING
SYSTEMS
(Sink current 0.5 to 3 mA)
Low: 0 to +0.6 V DC or Open
• Input impedance: 10 kΩ approx.
MEASURE-
MENT
SENSORS
Emission frequency 0: 250 μs or less (factory default setting)
Emission frequency 1: 450 μs or less
Emission frequency 2: 500 μs or less
Emission frequency 1: 2.5 ms or less (factory default setting)
Emission frequency 2: 2.8 ms or less
Emission frequency 3: 3.2 ms or less
STATIC
CONTROL
DEVICES
Emission frequency 3: 600 μs or less
Emission frequency 4: 5.0 ms or less
LASER
MARKERS
Sensitivity setting
2-level teaching / Limit teaching / Full-auto teaching
Operation indicator
Digital display
Orange LED (lights up when the output is ON)
4 digits (green) + 4 digits (red) LCD display
Incorporated
Fine sensitivity adjustment function
ON-delay / OFF-delay timer, switchable either effective or ineffective
[Timer period: 1 ms, 5 ms, 10 ms, 20 ms, 40 ms, 50 ms, 100 ms, 500 ms, 1,000 ms]
Timer function
Incorporated
Switchable either effective or ineffective
Attenuation function
Selection
Guide
Incorporated
Emission frequency selection method (Note 2)
(Functions at emission frequency 1, 2 or 3)
Incorporated
Emission frequency selection method (Note 2)
(Functions at emission frequency 1, 2, 3 or 4)
Interference prevention
function
Fibers
FT / FD / FR
–10 to +55 °C +14 to +131 °F (If 4 to 7 units are mounted close together: –10 to +50 °C +14 to +122 °F, if 8 to 16 units are mounted close together:
–10 to +45 °C +14 to +113 °F) (No dew condensation or icing allowed), Storage: –20 to +70 °C –4 to +158 °F
Fiber Sensor
Ambient temperature
Amplifiers
Ambient humidity
Ambient illuminance
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
35 to 85 % RH, Storage: 35 to 85 % RH
Incandescent light: 3,000 ℓx at the light-receiving face
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
1,000 V AC for one min. between all supply terminals connected together and enclosure (Note 3)
20 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure (Note 3)
10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude in X, Y and Z directions for two hours each
98 m/s2 acceleration (10 G approx.) in X, Y and Z directions for five times each
Red LED (Peak emission wavelength: 632 nm 0.025 mil)
Emitting element (modulated)
Material
Other
Products
Enclosure: Polycarbonate, Key switch: Polycarbonate, Fiber lock lever: PBT
Connector (Note 4)
Connecting method
Cable length
Total length up to 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
Net weight: 15 g approx.
Gross weight: 35 g approx.
Net weight: 15 g approx.
Gross weight: 75 g approx.
Net weight: 15 g approx.
Gross weight: 35 g approx.
Net weight: 15 g approx.
Gross weight: 75 g approx.
Weight
CN-14A-C2
(Connector attached cable, 2 m 6.562 ft long): 1pc.
CN-14A-C2
(Connector attached cable, 2 m 6.562 ft long): 1pc.
Accessory
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) When using the interference prevention function, set the emission frequencies for the amplifiers to be covered by the interference prevention function to
different frequency values.
However, the interference prevention function does not operate at emission frequency 0 (factory default setting) for the FX-101(P)(-Z) / FX-101(P)-CC2.
3) The voltage withstandability and the insulation resistance values given in the above table are for the amplifier only.
4) Connector attached cable CN-14A-C2 is not attached to the models that have no “-CC2” at the end of the model Nos.
Make sure to use the optional connector attached cable CN-14A(-R)-C□ or the connector CN-14A, or a connector manufactured by J.S.T. Mfg., Ltd.
(contact: SPHD-001T-P0.5, housing: PAP-04V-S).
Model Nos. having the suffix “-Z” are M8 plug-in connector type. Make sure to use the optional M8 attached connector cable CN-24A-C□.
Digital Fiber Sensor FX-100SERIES
133
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
NPN output type
FX-10□(-Z/-CC2)
SENSORS
PHOTO-
ELECTRIC
SENSORS
I/O circuit diagram
Terminal arrangement diagram
Connector type
Terminal No.
MICRO
PHOTO-
ELECTRIC
SENSORS
Color code of cable with connector
Terminal No.
Function
+V
(Brown) +V
1
AREA
SENSORS
D
1
2
3
4
Load
1
(Black) Output
2
Tr
SAFETY
2
3
4
Output
+
–
COMPONENTS
100 mA max.
(White) Extemal input
12 to 24 V DC
10 %
+8 V
ZD
External input
0 V
3
4
PRESSURE
SENSORS
* 1
(Blue) 0 V
Users’ circuit
INDUCTIVE
PROXIMITY
SENSORS
Internal circuit
M8 plug-in connector type
PARTICULAR
USE
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
SENSORS
Tr : NPN output transistor
Terminal No.
Function
+V
SENSOR
OPTIONS
1
2
3
4
1
* 1
WIRE-
SAVING
Output
SYSTEMS
Non-voltage contact or NPN open-collector transistor
External input
0 V
MEASURE-
MENT
or
SENSORS
STATIC
CONTROL
DEVICES
High (+8 V to +V DC, or open): Ineffective
Low [(0 to +2 V DC (source current 0.5 mA or less)]: Effective
LASER
MARKERS
PNP output type
FX-10□P(-Z/-CC2)
I/O circuit diagram
Terminal No.
Terminal arrangement diagram
Connector type
Color code of cable with connector
Terminal No.
Function
+V
(Brown) +V
* 1
1
2
3
4
1
(White) External input
3
Selection
Guide
2
3
4
Output
+
–
12 to 24 V DC
10 %
Z
D
100 mA max.
(Black) Output
Fibers
External input
0 V
Tr
D
2
4
FT / FD / FR
Load
(Blue) 0 V
Fiber sensor
Ampilifiers
Internal circuit
Users’ circuit
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
M8 plug-in connector type
Symbols … D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr : PNP output transistor
Terminal No.
Function
+V
1
2
3
4
1
3
* 1
Output
Non-voltage contact or PNP open-collector transistor
External input
0 V
Other
Products
or
High [ +4 V to +V DC (sink current 0.5 to 3 mA)]: Effective
Low (0 to +0.6 V DC, or open): Ineffective
Digital Fiber Sensor FX-100SERIES
134
FIBER
SENSING CHARACTERISTICS (TYPICAL)
Contact our office for sensing characteristics that are not contained here.
SENSORS
LASER
SENSORS
Thru-beam type
Thru-beam type
FT-FM2 FT-FM2S FT-FM2S4
FT-SFM2 FT-T80
FT-A8
FT-B8
Thru-beam
type
PHOTO-
Parallel deviation
• Vertical direction
ELECTRIC
SENSORS
• Horizontal direction
Parallel deviation
Parallel deviation
MICRO
4,000
4,000
PHOTO-
ELECTRIC
SENSORS
157.48
157.48
FX-102
FX-102
1,000
1,000
3,000
3,000
AREA
FX-102
39.370
39.370
FX-102
FX-101
118.11
118.11
SENSORS
FX-101
SAFETY
2,000
78.74
2,000
78.74
FX-101
FX-101
COMPONENTS
Fiber
head
Fiber
head
500
Fiber
head
500
Fiber
head
19.685
19.685
ℓ
PRESSURE
SENSORS
ℓ
ℓ
1,000
39.37
1,000
39.37
L
ℓ
8
mm 0.315 in
L
L
L
approx.
Fiber
Fiber
Fiber
head
INDUCTIVE
PROXIMITY
SENSORS
400
head
head
Fiber head
0
0
0
0
200
100
0
100
3.937
Right
200
400
200
0
200
200
100
0
100
3.937
Up
200
1,000
500
0
500
1,000
7.874
3.937
7.874
15.748 7.874
Left
7.874 15.748
Right
7.874
3.937
7.874
39.37 19.685
Left
19.685 39.37
Right
PARTICULAR
USE
Down
Center
Left
Center
Center
Center
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
SENSORS
FT-NFM2 FT-NFM2S
FT-NFM2S4 FT-SNFM2
Thru-beam type
Thru-beam type
Thru-beam type
FT-W8 FT-WS8
FT-P81X
FT-W4 FT-WS4
Thru-beam
type
SENSOR
OPTIONS
WIRE-
SAVING
SYSTEMS
Parallel deviation
Parallel deviation
Parallel deviation
Parallel deviation
400
800
15.748
9.843
MEASURE-
MENT
FX-102
SENSORS
1,000
39.370
200
300
600
7.874
STATIC
FX-102
FX-101
23.622
FX-102
FX-101
11.811
CONTROL
DEVICES
FX-101
FX-102
200
400
LASER
7.874
15.748
FX-101
500
100
MARKERS
Fiber
head
Fiber
head
Fiber
head
Fiber
head
19.685
3.937
ℓ
ℓ
ℓ
ℓ
200
100
L
L
L
3.937
7.874
L
Fiber
Fiber
Fiber
Fiber
head
head
head
head
0
0
0
0
200
100
100
200
400
200
0
200
400
100
50
0
50
1.969
Right
100
200
100
0
100
200
7.874
3.937
3.937
7.874
15.748 7.874
Left
7.874 15.748
Right
3.937
1.969
3.937
7.874
3.937
3.937 7.874
Right
Left
Center
Right
Center
Left
Center
Left
Center
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Reflective type
Reflective type
Reflective type
Reflective type
FD-B8
FD-FM2
FD-G4
FD-G6X
Sensing field
Sensing field
Sensing field
Sensing field
Selection
Guide
200
FX-102
FX-101
7.874
FX-102
Fibers
400
400
100
FT / FD / FR
150
15.748
15.748
3.937
5.906
FX-102
FX-101
Fiber Sensor
Amplifiers
FX-102
100
FX-101
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
3.937
200
50
200
FX-101
7.874
1.969
7.874
White non-glossy paper
White non-glossy paper
White non-glossy paper
White non-glossy paper
ℓ
L
ℓ
ℓ
ℓ
50
1.969
L
L
L
Fiber
head
Fiber
head
Fiber
head
Fiber
head
0
0
0
0
100
50
0
50
100
100
50
0
50
100
3.937
40
20
0
20
40
40
20
0
20
40
3.937
1.969
1.969
3.937
3.937
1.969
1.969
1.575
0.787
0.787
1.575
1.575
0.787
0.787 1.575
Right
Left
Center
Right
Left
Center
Right
Left
Center
Right
Left
Center
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Other
FD-NFM2 FD-NFM2S FD-NFM2S4
FD-SNFM2 FD-T40
Reflective type
Reflective type
Reflective type
FD-P81X
FD-W8 FD-WS8 FD-WT8
FD-WG4 FD-WSG4
Reflective
type
Products
Sensing field
Sensing field
Sensing field
Sensing field
80
3.150
FX-102
FX-102
100
200
200
60
3.937
7.874
7.874
2.362
FX-102
FX-102
FX-101
FX-101
40
FX-101
1.575
50
100
100
1.969
3.937
3.937
White non-glossy paper
White non-glossy paper
White non-glossy paper
White non-glossy paper
FX-101
ℓ
ℓ
ℓ
ℓ
20
0.787
L
L
L
L
Fiber
head
Fiber
head
Fiber
head
Fiber
head
0
0
0
0
40
20
0
20
40
1.575
20
10
0
10
20
0.787
20
10
0
10
20
0.787
40
20
0
20
40
1.575
0.787
0.787
0.787
0.394
0.394
0.787
0.394
0.394
1.575
0.787
0.787
1.575
Left
Center
Right
Left
Center
Right
Left
Center
Right
Left
Center
Right
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Operating point ℓ (mm in)
Digital Fiber Sensor FX-100SERIES
135
Refer to p.986~ for general precautions, and to the “Operation Guide” or “SUNX website”
(http://www.sunx.com) for details pertaining to operating instructions for the amplifier.
FIBER
PRECAUTIONS FOR PROPER USE
SENSORS
LASER
SENSORS
Part description
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
PHOTO-
ELECTRIC
SENSORS
ON key /
Setting value UP key
OFF key /
Setting value DOWN key
Operation indicator
(Orange)
MICRO
MODE key
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
Digital display (Green)
(Threshold value)
Digital display (Red)
(Incident light intensity)
SAFETY
COMPONENTS
Using in combination with the FX-300 / FX-400 series
Setting mode
PRESSURE
SENSORS
• The FX-100 series does not use the horizontal
connectors that are used with the FX-300 / FX-400
series. Please note that horizontal connection cannot be
performed using a connector attached cable. In addition,
the optical communication function is not equipped on
the FX-100 series, so it is unable to perform interference
prevention for use with the FX-300 / FX-400 series.
If using the FX-100 series together with the FX-300 /
FX-400 series side-by-side, please set the same models
together in groups.
• Setting mode appears after the MODE key is pressed for
2 sec. in RUN mode.
INDUCTIVE
PROXIMITY
SENSORS
Setting item Factory setting
Description
PARTICULAR
USE
SENSORS
Teaching
mode
Threshold value can be set in 2-level teaching,
limit teaching, or full-auto teaching.
SENSOR
OPTIONS
Output
operation
[Dark-ON]
setting
WIRE-
SAVING
Light-ON or Dark-ON can be set.
SYSTEMS
MEASURE-
MENT
Timer
SENSORS
Mounting
Without timer, ON delay timer, or OFF delay
operation
setting
STATIC
CONTROL
DEVICES
[Without timer] timer can be set.
<When using a DIN rail>
How to mount the amplifier
In case of setting ON-delay timer or OFF-delay
timer in the timer operation setting mode, timer
can be set. When timer is not set, this mode is
not displayed.
LASER
[ON-delay timer: 10 ms]
[OFF-delay timer: 10 ms]
Timer
setting
MARKERS
1
Fit the rear part of the mounting
section of the amplifier on a 35 mm
1.378 in width DIN rail.
Press down the rear part of the
mounting section of the unit on the
35 mm 1.378 in width DIN rail and
fit the front part of the mounting
section to the DIN rail.
Emission
amount
setting
Setting for reduced intensity of emission
amount is possible when the incident light
intensity is saturated.
2
2
[OFF]
1
35 mm 1.378 in width DIN rail
FX-101□
In case of using the fiber heads in parallel,
interference can be prevented by setting
different emission frequency. However, when
emission frequency 0 is set, interference
cannot be prevented. Response time
0 (Response time:
250 μs or less)
Emission
frequency
setting
How to remove the amplifier
Selection
Guide
FX-102□
1
corresponds to emission frequency. For
details, refer to “SPECIFICATIONS” on p.132.
1
Push the amplifier forward.
Lift up the front part of the
Fibers
1 (Response time:
2.5 ms or less)
2
2
FT / FD / FR
amplifier to remove it.
Fiber sensor
Ampilifiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Note: Take care that if the front part is lifted without pushing the amplifier
forward, the hook on the rear portion of the mounting section is likely
to break.
<When using screws with washers>
• Use M3 screws with washers
for mounting. The tightening
torque should be 0.5 N·m or
less.
Other
Products
M3 screw
with washer
Digital Fiber Sensor FX-100SERIES
136
Refer to p.986~ for general precautions, and to the “Operation Guide” or “SUNX website”
(http://www.sunx.com) for details pertaining to operating instructions for the amplifier.
FIBER
PRECAUTIONS FOR PROPER USE
SENSORS
LASER
PRO mode
Setting copy function
SENSORS
• This can copy the settings of the master side amplifier to
the slave side amplifier.
• PRO mode appears after the MODE key is pressed for 4
sec. in RUN mode.
PHOTO-
ELECTRIC
SENSORS
Setting item Factory setting
Description
MICRO
• Be sure to use the setting copy function between the
identical models (Between FX-10□ models or FX-102□
models).
This function cannot be used between different
models.
• Only one sensor can be connected on slave side with a
master side sensor for the setting copy function.
• Threshold value, output operation setting, timer
operation setting, timer setting, light-emitting amount
setting, shift setting, ECO setting, digital display
inversion setting, and threshold value margin setting
can be copied.
PHOTO-
ELECTRIC
SENSORS
Shift amount can be selected from 0 to 80 % in
the limit teaching. Select 0 % when it is desired
to set the present incident light intensity as a
threshold value.
Shift
AREA
setting
[Shift amount 15 %]
[Emission halt]
SENSORS
SAFETY
External
input
setting
COMPONENTS
Extemal input can be selected from emission
halt, limit +, limit -, AUTO, and ECO.
PRESSURE
SENSORS
When incident light intensity exceeds threshold
value, this mode can change the threshold
value with each set cycle depending on
variations of the incident light intensity. The
follow-up shift amount is same as the one
set in the shift setting mode. However, the
threshold value is not stored.
Threshold
value
INDUCTIVE
PROXIMITY
SENSORS
follow-up
cycle
[OFF]
PARTICULAR
USE
setting
(Note 1)
SENSORS
<Setting procedures>
SENSOR
OPTIONS
Variations can be reduced by correcting the
present incident light intensity in each amplifier
to a target value. Target value to offset incident
light intensity can be selected from 0 to 2,000
by 100 unit each. For example, if the target
value is set to 2,000 when the incident light
intensity is 1,500, the incident light intensity
becomes 2,000.
1
Set the setting copy mode of the master side amplifier to
“Copy sending ON”, and press the MODE key so that
GETA
WIRE-
SAVING
SYSTEMS
function
setting
“
” is shown on the digital display and the
[OFF]
sensor is in copy ready state. For the setting method,
refer to “Operation guide”.
Turn off the master side amplifier.
Connect the master side amplifier with the slave side
amplifier as shown below.
(Note 2, 3)
MEASURE-
MENT
SENSORS
2
3
STATIC
It is possible to light up / turn off the digital
display. When ECO setting mode is ON, the
display turns off in 20 sec. approx. in RUN
mode. To light up the display again, press any
key for 2 sec. or more.
CONTROL
DEVICES
ECO
LASER
setting
[OFF]
[OFF]
Color code of cable with connector
MARKERS
(Brown) +V
Master side amplifier
Slave side amplifier
Digital
(Black) Input
(White) Extemal input
(Blue) 0 V
+
–
12 to 24V DC
10 %
display
inversion
setting
Digital display can be inverted.
Margin for threshold value to the present
incident light intensity can be checked. When
there is no margin, it is possible to make the
digital display blink.
(Brown) +V
(Black) Input
(White) Extemal input
(Blue) 0 V
Threshold
value
: Set to “OFF”: does not function.
: Green blinks.
margin
setting
[OFF]
Selection
Guide
: Red blinks.
4
5
Turn on the master side amplifier and the slave side
amplifier at the same time. (Note)
Fibers
: Red and green blink.
FT / FD / FR
“
” is shown on the green digital display of the master
The settings of the master side amplifier can
be copied to the slave side amplifier.
For details, refer to “Setting copy function.”
Setting
copy
Fiber Sensor
side amplifier and 4-digit code is shown on the red
Amplifiers
[NO]
[NO]
digital display of it, then the copying starts. During copy
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
communication, “
display of the slave side amplifier, and the ongoing copy
communication indicator (“ ” “ ” “
”) is displayed on the red digital display.
” is shown on the green digital
Reset
Returns to default settings (factory settings.)
”
Notes: 1) If the incident light intensity becomes “300” or less, the follow-up
operation stops. In that condition, threshold value [digital display
(green)] blinks.
“
6
When the copying is completed, “
” is shown on the
This function can be used when thru-beam type or retroreflective
type fiber is applied to this product. If reflective type fiber is
applied, the function cannot be used depending on use conditions.
2) If MODE key is pressed in RUN mode when GETA function is
used, the incident light intensity before setting GETA function is
displayed on the red digital display for 2 sec. approx.
3) When GETA function is used in saturation of incident light intensity
(4,000 or more,) “
Correction value is up to 4,000.
green digital display of the slave side amplifier, while the
4-digit code (the same code as the master side amplifier)
is shown on the red digital display of it.
Turn off the power of the master side amplifier and the
slave side amplifier and disconnect the wire.
Other
7
Products
3
* If copying the settings to another amplifier repeatedly, follow the steps
” is indicated on the red digital display.
7
to
.
Note: Take care that if the power is not turned on at the same time, the
setting contents may not be copied.
<To cancel the setting copy mode of the master side amplifier>
1
While the slave side amplifier is disconnected, turn on
the power of the master side amplifier.
2
Press the MODE key for 2 sec. approx.
Digital Fiber Sensor FX-100SERIES
137
Refer to p.986~ for general precautions, and to the “Operation Guide” or “SUNX website”
(http://www.sunx.com) for details pertaining to operating instructions for the amplifier.
FIBER
PRECAUTIONS FOR PROPER USE
SENSORS
LASER
Quick setting function
Code setting function
SENSORS
• Settings for “output operation”, “light-emitting amount”,
“timer”, and “emission frequency” are possible simply by
selecting a setting number.
• The quick setting function makes it possible to set
the content of the SET Mode (output operation, timer
operation, amount of light emitted, and frequency of light
emitted) simply by selecting a setting number.
• While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 2
seconds will switch to the quick setting function.
• Settings for “output operation”, “timer”, “emission
PHOTO-
ELECTRIC
SENSORS
amount”, “emission frequency”, “ECO”, “external input”,
and “shift amount” are possible by selecting codes
discretionary.
• The code setting function makes it possible to set the
output operation, timer operation, amount of light emitted,
frequency of light emitted, ECO setting, external input,
and amount of shift by selecting a code of one’s choice.
• While in the RUN Mode, pressing and holding both
the ON key ( ) and OFF key ( ) simultaneously for 4
seconds will switch to the code setting function.
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
SAFETY
COMPONENTS
PRESSURE
SENSORS
<Table of quick setting numbers>
INDUCTIVE
PROXIMITY
SENSORS
<Code table>
No.
Output operation Emission amount setting
Timer
D-ON
D-ON
D-ON
D-ON
D-ON
D-ON
D-ON
D-ON
D-ON
D-ON
L-ON
L-ON
L-ON
L-ON
L-ON
L-ON
L-ON
L-ON
L-ON
L-ON
OFF
ON
non
PARTICULAR
USE
non
SENSORS
OFF
ON
ofd 10 ms
ofd 10 ms
ofd 40 ms
ofd 40 ms
ond 10 ms
ond 10 ms
ond 40 ms
ond 40 ms
ond 40 ms
ond 40 ms
ond 10 ms
ond 10 ms
ofd 40 ms
ofd 40 ms
ofd 10 ms
ofd 10 ms
non
SENSOR
OPTIONS
1st digit
Timer
2nd digit
Emission
Frequency
3rd digit
4th digit
Emission
amount
setting
OFF
ON
Code
Output
Extemal Shift
input
WIRE-
SAVING
ECO
operation (Note5)
(Note5)
5 %
SYSTEMS
FX-101□ FX-102□
OFF
ON
MEASURE-
MENT
non
0
1
2
3
0
1
2
3
1
2
3
4
1
2
3
4
E_oF
SENSORS
ond 10 ms
Limit [+] 10 %
OFF Limit [–] 15 %
OFF
ON
OFF
ON
STATIC
CONTROL
DEVICES
D-on
L-on
ond 40 ms
ofd 10 ms
ofd 40 ms
non
Auto
Eco
20 %
25 %
30 %
ON
LASER
OFF
ON
MARKERS
E_oF
ond 10 ms
ond 40 ms
ofd 10 ms
ofd 40 ms
Limit [+] 35 %
Limit [–] 40 %
OFF
ON
ON
Auto
Eco
45 %
50 %
OFF
ON
Notes: 1) When the present setting is out of the code setting range, “ ” is
shown.
OFF
ON
When “ ” is selected, the set content of the digit is not changed.
2) The factory setting is “
”.
OFF
non
Selection
Guide
Others
Fibers
• Do not use during the initial transient time (0.5 sec.) after
the power supply is switched on.
• EEPROM is adopted to this product. It is not possible to
conduct teaching 100 thousand times or more, because
of the EEPROM’s lifetime.
FT / FD / FR
Fiber sensor
Ampilifiers
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
Other
Products
Digital Fiber Sensor FX-100SERIES
138
Refer to p.106
~ for fiber dimensions.
FIBER
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from the website: http://www.sunx.com
SENSORS
LASER
SENSORS
Amplifier
Amplifier
FX-101□ FX-102□
FX-101(P)-Z FX-102(P)-Z
PHOTO-
ELECTRIC
SENSORS
6
6
10.85
0.236 0.236
0.427
6 0.236 6 0.236
47 1.850
47 1.850
29 1.142
MICRO
29 1.142
PHOTO-
ELECTRIC
SENSORS
0.8
2.7
0.7
20
12.2
0.8
12.2
0.031
0.106
0.028
0.787
0.480
0.480
0.031
0.7 0.028
AREA
SENSORS
OFF key / Setting value DOWN key
ON key / Setting value UP key
4.1
OFF key / Setting value DOWN key
ON key / Setting value UP key
Operation indicator (Orange)
4.1
2.7
0.106
0.161
Operation indicator (Orange)
0.161
SAFETY
Digital display (Green, Red)
MODE key
Digital display (Green, Red)
COMPONENTS
MODE key
9
9
1
1
1.1
0.354
PRESSURE
SENSORS
0.354
0.039
0.039
0.043
7
7
ø6.5
INDUCTIVE
PROXIMITY
SENSORS
0.276
0.276
0.8
1.1
ø0.256
0.031
0.043
30
30
10
4
0.157
10
1.181
0.394
1.181
3 0.118
0.394
PARTICULAR
USE
10
10
8.1
0.394
0.319
0.394
SENSORS
ø3.2
4
ø3.2
3.2
3.2
0.126
ø0.126
0.157
ø0.126
8.1
0.319
3
2
0.126
SENSOR
OPTIONS
50 1.969
35 1.378
64.5 2.539
0.118
5.5 0.217
2
0.079
13.5
5.5
0.079
50 1.969
0.531
0.217
13.5
WIRE-
35 1.378
64.5 2.539
Suitable for 35 mm 1.378 in width DIN rail
0.531
SAVING
SYSTEMS
Suitable for 35 mm 1.378 in width DIN rail
MEASURE-
MENT
Assembly dimensions with optional protective cover
(FC-FX-1)
SENSORS
STATIC
0.75 0.030
CONTROL
DEVICES
LASER
9
66.2
MARKERS
2 0.079
2 0.079
0.354
2.606
6 0.236
7
0.276
0.8
1.1
0.031
0.043
30
10
1.181
0.394
3 0.118
10
8.1
0.394
0.319
ø3.2
ø0.126
3.2
4
0.126
0.157
2
0.079
50 1.969
35 1.378
64.5 2.539
5.5 0.217
13.5
0.531
Selection
Guide
Suitable for 35 mm 1.378 in width DIN rail
Fibers
FT / FD / FR
Amplifer mounting bracket (Optional)
End plate (Optional)
MS-DIN-4
MS-DIN-E
Fiber Sensor
Amplifiers
ø7.2 mm ø0.283 in
ø3.2 ø0.126
7.2 mm 0.283 in
3.2
FX-100
FX-300
FX-410
FX-311
FX-11A
FX-301-F
spot facing, 4 0.157 deep
spot facing, 4 0.157 deep
0.126
M3 (Iength 18 mm 0.709 in) pan head screws
3 0.118
2.75 0.108
3
60
2.362
M3 Square nut
5.6
0.118
15
1
0.591
0.220
0.039
9.25
15
0.364
0.591
6.2 mm 0.244 in
spot facing, 3 0.118 deep
24.7
ø6.2 mm ø0.244 in
spot facing, 3 0.118 deep
0.972
9
3.2
0.126
ø3.2 ø0.126
0.354
32
1.6
0.063
Other
4
1.260
Products
11.5
0.157
0.453
Suitable for 35 mm 1.378 in width DIN rail
1
4
Material: Polycarbonate
0.039
0.157
24.5
0.965
35
5
0.197
1.378
Material: PBT
Connector attached cable (Optional)
CN-14A-C□ CN-14A-R-C□
CN-14A-C2 is attached FX-101(P)-CC2 / FX-102(P)-CC2
• Length L
L
35
50
(
)
(
)
1.378
1.969
8
8
Model No.
Length L
(
)
0.315
(
)
0.315
1,000 39.370
2,000 78.740
3,000 118.110
5,000 196.850
CN-14A(-R)-C1
CN-14A(-R)-C2
CN-14A(-R)-C3
CN-14A(-R)-C5
ø3.7 ø0.146 cable
FD-F41 相关器件
型号 | 制造商 | 描述 | 价格 | 文档 |
FD-FM2 | ETC | Digital Fiber Sensor FX-100 SERIES | 获取价格 | |
FD-FM2S | ETC | Digital Fiber Sensor FX-100 SERIES | 获取价格 | |
FD-FM2S4 | ETC | Digital Fiber Sensor FX-100 SERIES | 获取价格 | |
FD-FREQ-BBD10050 | FOX | Parallel - 5Th Overtone Quartz Crystal, 84MHz Min, 160MHz Max, ROHS COMPLIANT, CERAMIC, SMD, 4 PIN | 获取价格 | |
FD-FREQ1-BBD10010 | FOX | Parallel - Fundamental Quartz Crystal, 6MHz Min, 10MHz Max, ROHS COMPLIANT, CERAMIC, SMD, 4 PIN | 获取价格 | |
FD-FREQ6-BBD00050 | FOX | Series - 5Th Overtone Quartz Crystal, 84MHz Min, 200MHz Max, ROHS COMPLIANT, CERAMIC, SMD, 4 PIN | 获取价格 | |
FD-G6 | ETC | Digital Fiber Sensor FX-100 SERIES | 获取价格 | |
FD-G6X | ETC | Digital Fiber Sensor FX-100 SERIES | 获取价格 | |
FD-H13-FM2 | ETC | Digital Fiber Sensor FX-100 SERIES | 获取价格 | |
FD-H18-L31 | ETC | Digital Fiber Sensor FX-100 SERIES | 获取价格 |
FD-F41 相关文章
- 2024-09-20
- 5
- 2024-09-20
- 8
- 2024-09-20
- 8
- 2024-09-20
- 6