Solid State Relay  
G3MB  
Low cost Subminiature PCB mounting  
2 amp Single in-line package (SIP) SSR  
• Bottom is approximately 3 times smaller than G3M.  
• Low cost “SIP” package switches up to 2A loads.  
• Built in Snubber circuit and input resistor as option.  
Two footprints available for design flexibility.  
• The G3MB-202PEG-4-DC20MA crosses directly to the  
Motorola M0C2A-60 series power triac.  
Ordering Information  
To Order: Specify input voltage at end of part number. Example: G3MB-202P-DC24  
Isolation  
Output  
terminal  
pitch  
Zero  
cross  
Input  
resistor  
Built-in  
snubber  
circuit  
Rated output  
load  
Rated  
input  
voltage  
Model  
Phototriac 7.62 mm  
Yes  
Yes  
Yes  
2 A at 100 to 240 VAC  
2 A at 100 to 240 VAC  
2 A at 100 to 240 VAC  
2 A at 100 to 240 VAC  
5 VDC  
G3MB-202P  
12 VDC  
24 VDC  
5 VDC  
No  
Yes  
No  
G3MB-202PL  
G3MB-202P-4  
G3MB-202PL-4  
12 VDC  
24 VDC  
5 VDC  
5.08 mm  
12 VDC  
24 VDC  
5 VDC  
12 VDC  
24 VDC  
Yes  
No  
No  
No  
2 A at 100 to 240 VAC  
2 A at 100 to 240 VAC  
N/A *(See Note) G3MB-202PEG-4-DC20MA  
N/A *(See Note) G3MB-202PLEG-4-DC20MA  
Note: 1. For versions without input voltage specified, a current limiting resistor must be placed in series with the input. See LED drive specifications  
and recommendations below.  
2. TUV versions available. Contact your local Omron representative.  
1
Solid State Relay G3MB  
Specifications  
Input Rating  
Models with Input Resistor  
Rated voltage  
Operating range  
Input impedance  
5 VDC  
4 to 6 VDC  
440 20ꢀ  
1k 20ꢀ  
12 VDC  
24 VDC  
9.60 to 14.40 VDC  
19.20 to 28.80 VDC  
2.20k 20ꢀ  
Output Rating  
Model  
Rated load voltage  
Load voltage range  
Load current  
Surge current  
G3MB-202  
100 to 240 VAC  
75 to 264 VAC  
0.10 to 2 A  
30 A (60 Hz, 1 cycle)  
LED Drive Data  
Models without Input Resistor  
LED forward current  
50 mA max.  
1 A max.  
Repetitive peak LED forward current  
LED reverse voltage  
5 V max.  
Recommended LED Operating Conditions  
Models without Input Resistor  
Min.  
Standard  
Max.  
20 mA  
LED forward current  
Must drop voltage  
5 mA  
0
10 mA  
1 V  
Characteristics  
Type  
G3MB-202P  
G3MB-202PEG  
G3MB-202PL  
G3MB-202PLEG  
Operate time  
1/2 of load power source  
cycle + 1 ms max.  
1 ms max.  
Release time  
1/2 of load power source cycle + 1 ms max.  
Output ON voltage drop  
Leakage current  
Non-repetitive peak surge  
Output  
1.60 V (RMS) max.  
1 mA max. at 100 VAC, 1.50 mA at 200 VAC  
30 A  
PIV (VDRM)  
di/dt  
600 V  
40 A/µs  
dv/dt  
I2t  
100 V/µs  
4 A2s  
Junction temperature (Tj)  
Insulation resistance  
Dielectric strength  
Vibration  
125°C (257°F) max.  
1,000 Mmin. at 500 VDC  
2500 VAC, 50/60 Hz for 1 minute; 3750 VAC max., 1 second  
10 to 55 Hz, 0.75 mm (0.03 in) double amplitude, approx. 5 G  
Approx. 100 G  
Malfunction  
Malfunction  
Operating  
Storage  
Shock  
Ambient temperature  
-30° to 80°C (-22° to 176°F) with no icing  
-30° to 100°C (-22° to 212°F) with no icing  
45ꢀ to 85ꢀ RH  
Humidity  
Weight  
Operating  
Approx. 5 g (0.18 oz)  
Note: Data shown are of initial value.  
Solid State Relay G3MB  
2
Characteristic Data  
Load current vs. ambient  
Inrush current resistivity  
temperature characteristics  
Non-repetitive (Keep the inrush current to  
half the rated value if it occurs repetitively.)  
40  
30  
20  
2.5  
2.0  
1.5  
1.0  
0.5  
0
10  
0
-40 -20  
0
20 25 40 60  
80 100  
10  
30 50 100 300 500 1,000 5,000 10,000  
Switching current (A)  
Ambient temperature ˚C  
100  
Dimensions  
Unit: mm (inch)  
Relays  
PCB Dimensions  
(Bottom view)  
G3MB  
Four 1.0 (0.04) dia.  
2.54 (0.1)  
20.5  
(0.81)  
max.  
2.54  
(0.1)  
3.9 (0.15)  
7.62  
(0.30)  
1.4 (0.06)  
0.4 (0.02)  
0.7  
(0.03)  
2.54 (0.10)  
24.5 (0.96)  
G3MB (-4)  
max.  
Four 1.0 (0.04) dia.  
5.5  
(0.22)  
max  
2.54  
(0.1)  
Terminal Arrangement/  
Internal Connections  
(Bottom view)  
4 (-) 3 (+)  
2
1
INPUT  
LOAD  
3
Solid State Relay G3MB  
Approvals  
UL (File No. E64562)  
SSR Type  
Input voltage  
5 to 24 VDC  
Load type  
General purpose  
Tungsten  
Load ratings  
G3MB-102P  
2 A, 120 VAC  
1 A, 120 VAC  
Motor  
1.60 FLA/9.60 LRA, 120 VAC  
2 A, 240 VAC  
G3MB-202P  
General purpose  
Tungsten  
G3MB-202PL  
G3MB-202PEG  
G3MB-202PLEG  
1 A, 240 VAC  
Motor  
1.60 FLA/9.60 LRA, 240 VAC  
CSA (File No. LR35535)  
SSR Type  
G3MB-102P  
Input voltage  
5 to 24 VDC  
Load type  
General purpose  
Tungsten  
Load ratings  
2 A, 120 VAC  
1 A, 120 VAC  
Motor  
1.60 FLA/8.60 LRA, 120 VAC  
2 A, 240 VAC  
G3MB-202P  
General purpose  
Tungsten  
G3MB-202PL  
1 A, 240 VAC  
Motor  
1.60 FLA/8.60 LRA, 240 VAC  
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance characteristics  
individually defined in this catalog.  
2. In the interest of product improvement, specifications are subject to change.  
Precautions  
See General Information Section near the back of this catalog for  
Solid State Precautions.  
Protective Component  
The input circuitry does not incorporate a circuit protecting the SSR  
from being damaged due to a reversed connection. Make sure that  
the polarity is correct when connecting the input lines.  
Soldering must be completed within 10 seconds at 260°C or less.  
Make sure that the space between the bottom of the relay and the  
PCB is 0.1 mm or less. When making holes on the PCB for the  
relay’s edge terminals, the hole diameters should be slightly smaller  
than the actual diameters of the edge terminals. This will reduce  
unnecessary space between the bottom of the relay and the PCB.  
To use the SSR output for phase control, select a model that does  
not incorporate a zero-cross function.  
The SSR case serves to dissipate heat. When mounting more than  
three SSRs as a group, pay attention to the ambient temperature rise  
and install the Relays so that they are adequately ventilated. If poor  
ventilation is unavoidable, reduce the load current by half.  
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4  
Solid State Relay G3MB  
4
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, divide by 25.4  
OMRON ON-LINE  
Global - http://www.omron.com  
USA - http://www.omron.com/oei  
Canada - http://www.omron.ca  
OMRON ELECTRONICS LLC  
One Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Toronto, Ontario M1B 5V8  
847-882-2288  
416-286-6465  
Cat. No. GC RLY8  
5/03  
Specifications subject to change without notice  
Printed in USA  
5
Solid State Relay G3MB  

相关型号:

G3MB-202P

Solid State Relay
OMRON

G3MB-202P-4

Solid State Relay
OMRON

G3MB-202P-4-DC12

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202P-4-DC24

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202P-4-UTU-DC24

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202P-4-UTU-DC5

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202P-DC12

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202P-DC24

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202P-DC5

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202P-UTU-DC12

Trigger Output SSR, 1-Channel, 2500V Isolation, SIP-4
OMRON

G3MB-202PEG

Solid State Relay
ETC

G3MB-202PEG-4-DC20MA

Solid State Relay
OMRON