G5AU-234PH [ETC]

;
G5AU-234PH
型号: G5AU-234PH
厂家: ETC    ETC
描述:

文件: 总7页 (文件大小:130K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Low Signal Relay  
G5A  
Subminiature 8.40 H x 9.90 W x 16 L mm  
(0.33 H x 0.38 W x 0.63 L in)  
Unique moving magnet armature (Moving  
Loop System) reduces relay size, magnetic  
interference, and contact bounce time  
Low nominal power consumption (200 mW)  
Bifurcated crossbar contact assures highly  
reliable switching of loads as low as  
10 mVDC, 0.1 mA (reference value)  
Automatic flow or dip soldering possible  
Available in standard, high-sensitivity,  
high-dielectric (FCC part 68), low  
thermoelectromotive force, and ultrasonic  
cleaning versions  
Highly stable magnetic circuit for latching  
endurance and excellent resistance to  
vibration and shock  
Single or double coil winding types available  
Ordering Information  
To Order: Select the part number and add the desired coil voltage rating (e.g., G5AU-234P-DC12).  
NON-LATCHING  
Type  
Contact form  
DPDT  
Construction  
Semi-sealed  
Sealed  
Part number  
G5A-237P  
Standard  
G5A-234P  
High-sensitivity  
FCC part 68  
Semi-sealed  
Sealed  
G5A-237PH  
G5A-234PH  
G5A-237P-FC  
G5A-234P-FC  
Semi-sealed  
Sealed  
Note: High-sensitivity versions of the FC type are also available.  
LATCHING  
Part number  
Single-winding  
latching  
Double-winding  
latching  
Type  
Contact form  
DPDT  
Construction  
Semi-sealed  
Sealed  
Standard  
G5AU-237P  
G5AK-237P  
G5AK-234P  
G5AU-234P  
High-sensitivity  
FCC part 68  
Semi-sealed  
Sealed  
G5AU-237PH  
G5AU-234PH  
G5AU-237P-FC  
G5AU-234P-FC  
Semi-sealed  
Sealed  
G5AK-237P-FC  
G5AK-234P-FC  
G5A  
G5A  
Specifications  
CONTACT DATA  
Load  
Resistive load (p.f. = 1)  
0.50 A at 30 VAC, 1 A at 30 VDC  
Ag (Au clad)  
Inductive load (p.f. = 0.4) (L/R = 7 ms)  
0.10 A at 30 VAC, 0.20 A at 30 VDC  
Rated load  
Contact material  
Carry current  
1 A  
Max. operating voltage  
Max. operating current  
Max. switching capacity  
Min. permissible load  
125 VAC, 125 VDC  
1 A (AC) 1 A (DC)  
37.50 VA, 33 W  
0.50 A (AC) 0.50 A (DC)  
12.50 VA 11 W  
10 µA, 10 mVDC  
COIL DATA  
Standard non-latching and FCC part 68 type (G5A-237P, G5A-234P, G5A-237P-FC, G5A-234P-FC)  
Coil inductance  
(ref. value) (H)  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
()  
Pick-up  
voltage  
Dropout  
voltage  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature  
OFF  
Armature  
ON  
% of rated voltage  
5
40  
125  
0.13  
0.17  
0.43  
0.71  
2.76  
7.44  
0.12  
0.16  
0.40  
0.68  
2.70  
7.25  
70% max.  
10% min.  
150%  
Approx. 200  
6
33.30  
22.20  
16.70  
8.30  
5.80  
180  
9
405  
12  
24  
48  
720  
2,880  
8,230  
Approx. 280  
High-sensitivity non-latching type (G5A-237PH, G5A-234PH)  
Coil inductance  
(ref. value) (H)  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
()  
Pick-up  
voltage  
Dropout  
voltage  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature  
OFF  
Armature  
ON  
% of rated voltage  
80% max. 10% min.  
5
30  
167  
240  
0.17  
0.22  
0.58  
1
0.16  
0.21  
0.54  
0.96  
3.80  
180%  
Approx. 150  
6
25  
9
16.70  
12.50  
6.50  
540  
12  
24  
960  
3,700  
3.90  
Single-winding latching type. Standard and FCC part 68 version (G5AU-237P, G5AU-234P, G5AU-237P-FC, G5AU-234P-FC)  
Coil inductance  
(ref. value) (H)  
Set  
pick-up  
voltage  
Reset  
dropout  
voltage  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
()  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature  
OFF  
Armature  
ON  
% of rated voltage  
80% max. 80% max.  
3
66.70  
40  
45  
0.02  
0.06  
0.08  
0.17  
0.29  
1.10  
0.02  
0.05  
0.07  
0.14  
0.24  
0.85  
200% max.  
Approx. 200  
5
125  
180  
405  
720  
2,880  
6
33.30  
22.20  
16.70  
8.30  
9
12  
24  
2
G5A  
G5A  
COIL DATA (continued)  
Double-winding latching type. Standard and FCC part 68 version (G5AK-237P, G5AK-234P, G5AK-237P-FC, G5AK-234P-FC)  
Coil inductance  
(ref. value) (H)  
Set  
pick-up  
voltage  
Reset  
dropout  
voltage  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
()  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature  
OFF  
Armature  
ON  
% of rated voltage  
80% max. 80% max.  
3
66.70  
40  
45  
0.02  
0.06  
0.08  
0.17  
0.29  
1.10  
0.02  
0.05  
0.07  
0.14  
0.24  
0.85  
200% max.  
Approx. 200  
5
125  
180  
405  
720  
2,880  
6
33.30  
22.20  
16.70  
8.30  
9
12  
24  
Single-winding latching type. High-sensitivity version (G5AU-237PH, G5AU-234PH)  
Coil inductance  
(ref. value) (H)  
Set  
pick-up  
voltage  
Reset  
dropout  
voltage  
Rated  
voltage  
(VDC)  
Rated  
current  
(mA)  
Coil  
resistance  
()  
Maximum  
voltage  
Power  
consumption  
(mW)  
Armature  
OFF  
Armature  
ON  
% of rated voltage  
80% max. 80% max.  
5
20  
250  
200% max.  
Approx. 200  
6
16.70  
11.10  
8.40  
4.20  
360  
9
810  
12  
24  
1,440  
5,760  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with a tolerance of ±10%.  
2. The operating characteristics are measured at a coil temperature of 23°C (73°F).  
CHARACTERISTICS  
Type  
Non-latching  
Latching  
Contact resistance  
Operate (set) time  
Release (reset) time  
Bounce time  
50 mmax.  
5 ms max. (mean value approx. 2.4 ms)  
5 ms max. (mean value approx. 1.1 ms)  
Approx. 0.5 ms  
5 ms max. (mean value approx. 2.0 ms)  
5 ms max. (mean value approx. 1.8 ms)  
Operate  
Release  
Approx. 0.5 ms  
Operating  
frequency  
Mechanical  
Electrical  
36,000 operations/hour  
18,000 operations/hour (under rated load)  
1,000 Mmin. (at 500 VDC)  
Insulation resistance  
Dielectric strength  
100 Mmin. (at 250 VDC)  
1,000 VAC, 50/60 Hz for 1 minute between coil and contacts  
1,000 VAC, 50/60 Hz for 1 minute between contacts of different poles  
500 VAC, 50/60 Hz for 1 minute between contacts of same pole  
750 VAC, 50/60 Hz for 1 minute between contacts of same pole  
250 VAC, 50/60 Hz for 1 minute  
Standard  
FC  
Set and Reset coils  
Mechanical durability  
Malfunction durability  
Mechanical durability  
Malfunction durability  
Vibration  
Shock  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
Approx. 100 G  
Approx. 30 G  
Ambient temperature  
Humidity  
-40 to 70°C (-40° to 158°F)  
45% to 85% RH  
Service life  
Mechanical  
Electrical  
50 million operations min.  
(at 18,000 operations/hour)  
1 million operations min.  
(at 18,000 operations/hour)  
See “Characteristic Data”  
Approx. 3 g (0.11 oz)  
Weight  
Note: Data shown are of initial value.  
3
G5A  
G5A  
CHARACTERISTIC DATA  
Maximum switching capacity  
Electrical service life  
Ambient temperature vs.  
maximum voltage (reference only)  
Rated operating voltage (V)  
Rated operating current (A)  
Ambient temperature (°C)  
Dimensions  
Unit: mm (inch)  
NON-LATCHING  
G5A-237P, G5A-237PH, G5A-237P-FC  
Internal connections  
Footprint  
(Bottom view)  
(Bottom view)  
G5A-234P, G5A-234PH, G5A-234P-FC  
Internal connections  
Footprint  
(Bottom view)  
(Bottom view)  
Note:  
and  
indicate mounting orientation marks.  
4
G5A  
G5A  
LATCHING  
G5AU-237P, G5AU-237PH, G5AU-237P-FC  
Internal connections  
Footprint  
(Bottom view)  
(Bottom view)  
G5AK-237P, G5AK-237PH, G5AK-237P-FC  
Internal connections  
Footprint  
(Bottom view)  
(Bottom view)  
G5AU-234P, G5AU-234PH, G5AU-234P-FC  
Internal connections  
Footprint  
(Bottom view)  
(Bottom view)  
G5AK-234P, G5AK-234PH, G5AK-234P-FC  
Internal connections  
Footprint  
(Bottom view)  
(Bottom view)  
Note:  
and  
indicate mounting orientation marks.  
5
G5A  
G5A  
APPROVALS  
UL (File No. E41515)/CSA (File No. LR24825)  
Type  
Contact form  
DPDT  
Coil ratings  
Contact ratings  
0.5 A, 60 VAC  
1 A, 30 VDC  
G5A-234P  
1.5 to 48 VDC  
G5A-234PH  
G5A-234P-FC  
G5A-237P  
G5A-237PH  
G5A-237P-FC  
G5AU-237P  
G5AU-237PH  
G5AU-237P-FC  
G5AK-237P  
G5AK-237P-FC  
G5AU-234P  
G5AU-234PH  
G5AU-234P-FC  
G5AK-234P  
G5AK-234P-FC  
0.5 A, 60 VAC  
0.5 A, 60 VDC  
1 A, 30 VDC  
Note: 1. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance  
characteristics individually defined in this catalog.  
2. In the interest of product improvement, specifications are subject to change.  
Hints on Correct Use  
Single-winding type (G5AU)  
Notes:  
Example of low-power drive circuit  
1. When applying the relay for practical use, make sure of the  
set or reset state of the relay; then determine the circuit  
constraints.  
1. The figure below shows a drive circuit (JAPAN PAT. NO.  
1239293) in which the latching relay can function like a  
general-purpose relay from a normal input pulse for  
switching.  
2. Because OMRON possesses the patent of this drive  
circuit, contact OMRON when adopting it.  
2. Use a charging current of capacitor C to operate the  
latching relay, which flows suddenly through diode D1,  
capacitor C, latching relay, and diode D2, and the relay  
contacts will be put in the locked state.  
3. Use a discharging current of capacitor C to release the  
latching relay, which flows through transistor TR, capacitor  
C, and the latching relay.  
6
G5A  
G5A  
OMRON ELECTRONICS, INC.  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. GC RLY7  
1/00  
Specifications subject to change without notice.  
Printed in the U.S.A.  
7

相关型号:

G5AU-234PH-DC6

Power/Signal Relay, DPDT, Latched, 0.017A (Coil), 6VDC (Coil), 200mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G5AU-237P-DC12

Power/Signal Relay, DPDT, Latched, 0.017A (Coil), 12VDC (Coil), 200mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G5AU-237P-DC24

Power/Signal Relay, DPDT, Latched, 0.008A (Coil), 24VDC (Coil), 200mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G5AU-237P-DC3

Power/Signal Relay, DPDT, Latched, 0.067A (Coil), 3VDC (Coil), 200mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G5AU-237P-DC5

Power/Signal Relay, DPDT, Latched, 0.04A (Coil), 5VDC (Coil), 200mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G5AU-237PH-DC12

Power/Signal Relay, DPDT, Latched, 0.008A (Coil), 12VDC (Coil), 200mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON

G5AU-237PH-DC9

Power/Signal Relay, DPDT, Latched, 0.011A (Coil), 9VDC (Coil), 200mW (Coil), 1A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, ROHS COMPLIANT
OMRON