G5S-1A-V-DC5 [ETC]
;型号: | G5S-1A-V-DC5 |
厂家: | ETC |
描述: |
|
文件: | 总6页 (文件大小:106K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
PCB Relay
G5S
Compact Single-pole Relay for
Switching Up To 5 A (Normally Open
Contact), Ideal for Fan Control of Air
Conditioners, and Heating Control of
Small Appliances
ꢀ Compact relay with high insulation
between coil and contacts
ꢀ Up to 5A switching on the NO contacts
ꢀ Ensures a withstand impulse voltage of
8,000 V between the coil and contacts
ꢀ Class B coil insulation available
ꢀ Conforms to UL, CSA, and IEC (TÜV)
Ordering Information
Classification
Enclosure rating
Plastic-sealed
Plastic-sealed
Part number
Single contact
SPDT
G5S-1 (-CB for Class B)
G5S-1A (-CB for class B)
SPST-NO
Note: When ordering, add the rated coil voltage to the model number.
Example: G5S-1 DC12
Rated coil voltage
MODEL NUMBER LEGEND
G5S-
-
-
-DC
1 2 3 4
5
2. Contact Form
1. Contact Pole
3. Insulation class
4. Enclosure
nil = plastic sealed
v = vented
5. Rated Coil Voltage
nil = standard
CB = Class B
nil = 1 form C
A = 1 form A
1: Single pole
5, 9, 12, 18, 24, 48 VDC
G5S
G5S
Specifications
COIL RATINGS
Rated voltage
5 VDC
80 mA
62.5 Ω
9 VDC
12 VDC
33.3 mA
360 Ω
18 VDC
22.2 mA
810 Ω
24 VDC
16.7 mA
1,440 Ω
48 VDC
8.3 mA
5,760 Ω
Rated current
44.4 mA
202.5 Ω
Coil resistance
Must operate voltage
Must release voltage
Max. voltage
75% max. of rated voltage
5% min. of rated voltage
150% of rated voltage at 23°C, 110% of rated voltage at 70°C
Power consumption
Approx. 400 mW
Note: Rated current and coil resistance are measured at 23°C with a tolerance of ±10%.
CONTACT RATINGS
Load
Resistive load
Inductive load
Rated load
2 A (NO)/2 A (NC) at 277 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 30 VDC
0.5 A at 250 VAC, cosφ=0.4
1 A at 250 VAC, cosφ=0.8
0.8 A at 250 VAC, cosφ=0.9
Contact material
Ag
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
5 A (NO)/3 A (NC)
277 VAC, 30 VDC
5 A (NO)/3 A (NC)
1 A
625 VA, 150 W (NO)
375 VA, 90 W (NC)
250 VA
Min. permissible load
10 mA at 5 VDC
-- 6
Note: P level: λ60=0.1 x 10 operation (with an operating frequency of 120 operations/min.)
CHARACTERISTICS
Contact resistance (See Note 2.)
Operate time (See Note 3.)
Release time (See Note 3.)
Insulation resistance (See Note 4.)
Dielectric strength
100 mΩ max.
10 ms max.
5 ms max.
1,000 MΩ min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
750 VAC, 50/60 Hz for 1 min between contacts of same polarity
Impulse withstand voltage
Vibration resistance
8 kV (1.2 x 50 µs)
Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes
2
Shock resistance
Destruction: 1,000 m/s (approx. 100G)
2
Malfunction: Energized: 100 m/s (approximately 10G)
2
Non-energized: 50 m/s (approximately 5G)
(This table continues on the next page.)
G5S
G5S
Characteristics Table -- continued from previous page
Mechanical
Electrical
5,000,000 operations (18,000 operations per hour)
Life expectancy (See Note 5.)
200,000 operations:1 A (NO)/1 A (NC) at 277-VAC resistive load
3 A (NO)/3 A (NC) at 125-VAC resistive load
100,000 operations:0.8 A (NO)/0.8 A (NC) at 250 VAC, cosφ=0.9
5 A (NO)/3 A (NC) at 30-VDC resistive load
50,000 operations: 2 A (NO)/2 A (NC) at 277-VAC resistive load
5 A (NO)/3 A (NC) at 125-VAC resistive load
Switching
frequency
1,800 operations per hour
Ambient temperature
Ambient humidity
Weight
Operating &
storage
-- 4 0 °C to 70°C (--40°F to 158°F) with no icing or condensation
-- 4 0 °C to 85°C (class B) (--40°F to 185°F)
Operating &
storage
35% to 85%
Approx. 8.0 g
Note: 1. The data shown above are initial values.
2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The operating time is possible with the rated voltage imposed with no contact bounce at an ambient temperature of 23°C.
4. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
5. The electrical life data items shown are possible at 23°C.
APPROVED STANDARDS
UL508 (File No. E41515)
CSA C22.2 (No. 14) (File No. LR31928)
Model
Coil ratings
12, 24 VDC
Contact ratings
Number of test operations
6,000
G5S-1 (-CB)
G5S-1A (-CB)
0.8 A, 277 VAC (resistive)
0.5 A, 250 VAC (resistive)
2 A, 120 VAC (resistive)
2 A, 30 VDC (resistive)
5 A, 125 VAC (resistive)
1/10 HP, 125 VAC
5 A, 277 VAC (resistive)
1/6 HP, 277 VAC
0.3 A, 110 VDC (resistive)
5 A, 30 VDC (resistive)
TÜV (IEC 255, VDE0435 File No. R9650783)
Electrical life tests are performed at 70°C.
Model
Coil ratings
12, 24 VDC
Contact ratings
Number of test operations
G5S-1 (-CB)
G5S-1A (-CB)
1.5 A, 277 VAC (resistive)
1 A, 250 VAC (resistive)
2 A, 30 VDC (resistive)
30,000
100,000
30,000
1 A, 250 VAC, cosφ=0.8
0.5 A, 250 VAC, cosφ=0.4
100,000
30,000
1 A, 250 VAC, cosφ=0.8 (NO only)
1 A, 250 VAC, cosφ=0.8 (NC only)
200,000
200,000
Note: Pollution Degree 2, Overvoltage Category II, Material Group III
G5S
G5S
Engineering Data
MAX. SWITCHING CAPACITY
10
10
30-VDC resistive
load (NO)
125-VAC resistive
load (NO)
5
30-VDC resistive
load (NC)
3
250-VAC inductive
load (cosφ=0.8)
2
1
1
125-VAC resistive
277-VAC resistive
load (NC)
load (NO/NC)
0.5
250-VAC resistive
load (NO/NC)
250-VAC inductive
load (cosφ=0.4)
0
0
10
100
277
1,000
10
100
277
1,000
0
0
Switching voltage (V)
Switching voltage (V)
AMBIENT TEMPERATURE VS.
MAXIMUM VOLTAGE
LIFE EXPECTANCY
200
10,000
180
160
125 VAC
(NO only)
1,000
100
140
120
110
100
80
250 VAC
(cosφ=0.9)
60
40
10
277 VAC
20
0
1
-- 4 0
-- 2 0
0
2 3
4 0
6 0 7 0 8 0
0
1
2
3
4
5
6
Ambient temperature (°C)
Switching current (A)
G5S
G5S
Dimensions
Unit: mm (inch)
G5S
SPDT
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(See
Note.)
(See
Note.)
Direction marker
Five, 1.3±0.1-dia. holes
(No coil polarity)
(See
Note.)
Note: Values in parentheses are average values.
SPST-NO
Terminal Arrangement/
Internal Connections
(Bottom View)
PCB Mounting Holes
(Bottom View)
Tolerance: ±0.1 mm
(See
Note.)
(See
Note.)
(1.08)
Direction marker
Four, 1.3±0.1-dia. holes
(No coil polarity)
(See
Note.)
Note: Values in parentheses are average values.
Precautions
For general precautions on PCB Relays, refer to the precautions provided in General Information of the Relay Product Data Book.
!
Caution
Do not touch the terminals of the Relay or the charted part of
the socket when power is supplied to the Relay. Otherwise, an
electric shock may occur.
G5S
G5S
NOTE: DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters to inches divide by 25.4.
OMRON ELECTRONICS, INC.
OMRON CANADA, INC.
One East Commerce Drive
885 Milner Avenue
Schaumburg, IL 60173
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. K102-E3-1
1/99
Specifications subject to change without notice.
Printed in U.S.A.
相关型号:
G5SB-149VDC
Power/Signal Relay, SPDT, Momentary, 0.044A (Coil), 9VDC (Coil), 400mW (Coil), 5A (Contact), 30VDC (Contact), DC Input, AC/DC Output, Through Hole-Straight Mount, LEAD FREE
OMRON
©2020 ICPDF网 联系我们和版权申明