G7L-1A-B-JCB-AC24 [ETC]

;
G7L-1A-B-JCB-AC24
型号: G7L-1A-B-JCB-AC24
厂家: ETC    ETC
描述:

文件: 总12页 (文件大小:316K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
General Purpose Relay  
G7L  
A high-capacity, high-withstand voltage relay  
compatible with mometary voltage drops  
No contact chattering for mometary voltage  
drops up to 50% of rated voltage  
UL Class B construction standard  
Wide-range AC-activated coil that handles  
100 to 120 VAC at either 50 or 60 Hz  
Miniature hinge for maximum switching  
capacity, particularly for inductive loads  
Flame resistant materials (UL94V-0-qualify-  
ing) used for all insulation material  
Quick-connect, screw, and PCB terminals  
available  
Standard models are UL, CSA, and TUV  
approved; VDE versions now available  
Conforming to IEC 950  
Ordering Information  
To Order: Select the part number and add the desired coil voltage rating (e.g., G7L-1A-T-CB-AC100/120).  
Replaces G5D series.  
Part number  
Type  
Contact form  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
SPST-NO  
DPST-NO  
Quick-connect terminal  
G7L-1A-T-CB (see note 1)  
G7L-2A-T-CB (see note 1)  
G7L-1A-TJ-CB (see note 1)  
G7L-2A-TJ-CB (see note 1)  
G7L-1A-TUB-CB  
G7L-2A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-2A-TUBJ-CB  
Screw terminal  
PCB terminal  
E bracket  
G7L-1A-B-CB (see note 1)  
G7L-2A-B-CB (see note 1)  
G7L-1A-BJ-CB (see note 1)  
G7L-2A-BJ-CB (see note 1)  
G7L-1A-BUB-CB  
G7L-2A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-2A-BUBJ-CB  
E bracket  
(with test button)  
Upper bracket  
Upper bracket  
(with test button)  
PCB mounting  
G7L-1A-P-CB  
G7L-2A-P-CB  
Note: 1. E bracket or socket must be used for mounting (part number R99-07G5D). Refer to “Accessories” section for options and  
part numbers.  
2. For VDE approved versions, please consult OMRON.  
G7L  
G7L  
MODEL NUMBER LEGEND  
G7L- - ■ ■ ■ ■  
1 2 3 4 5 6  
1. Contact form  
1A: SPST-NO  
2A: DPST-NO  
3. Mounting construction  
5. 80: VDE approved version  
No symbol: E bracket type  
(includes UL, CSA and TÜV)  
UB:  
Upper bracket type  
6. CB: Class B insulation  
7. Rated coil voltage  
2. Terminal shape  
4. Special functions  
T:  
P:  
B:  
Quick-connect terminals  
PCB terminals  
Screw terminals  
No symbol: Without test button  
J:  
With test button  
ACCESSORIES  
Quick-connect terminals  
Model  
Contact form  
SPST-NO  
G7L-1A-T  
Description  
DPST-NO  
G7L-2A-T  
Part number  
R99-07G5D  
P7LF-D  
E-brackets  
G7L-1A-TJ  
G7L-2A-TJ  
Track mounting adaptor  
Front connecting socket  
Cover  
P7LF-06 (see note)  
P7LF-C  
Screw terminals  
Model  
Contact form  
SPST-NO  
G7L-1A-B  
Description  
DPST-NO  
G7L-2A-B  
Part number  
R99-07G5D  
P7LF-D  
E-brackets  
G7L-1A-BJ  
G7L-2A-BJ  
Track mounting adaptor  
Note: P7LF-C cover is supplied with the P7LF-06 socket.  
Specifications  
CONTACT DATA  
G7L-1A-T, G7L-1A-B  
G7L-2A-T, G7L-2A-B  
G7L-1A-P, G7L-2A-P  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4)  
Resistive load  
(cosϕ = 1)  
Inductive load  
(cosϕ = 0.4)  
Load  
Rated load  
30 A, 220 VAC  
AgCdO  
25 A, 220 VAC  
20 A, 220 VAC  
20 A  
Contact material  
Carry current  
30 A  
25 A  
25 A  
Max. operating voltage  
Max. operating current  
Max. switching capacity  
Min. permissible load  
250 VAC  
30 A  
20 A  
6,600 VA  
100 mA, 5 VDC  
5,500 VA  
4,400 VA  
Note: P level: λ60 = 0.1 x 10-6 operation.  
COIL INTERNAL CIRCUIT  
DC operating coil  
AC operating coil  
2
G7L  
G7L  
COIL DATA  
AC  
Rated voltage  
(V)  
Rated current  
(mA)  
Resistance  
()  
Must operate  
Must release  
Max. voltage  
110% max.  
Power  
consumption  
% of rated voltage  
6
283  
18.90  
75  
75% max.  
15% min.  
Approx.1.70  
to 2.50 VA  
12  
142  
24  
71  
303  
50  
34  
1,310  
5,260  
21,000  
100/120  
200/240  
17.00/20.40  
8.50/10.20  
75 volts  
18 volts  
36 volts  
132 volts  
264 volts  
150 volts  
DC  
Rated voltage  
(V)  
Rated current  
(mA)  
Resistance  
()  
Must operate  
Must release  
Max. voltage  
110% max.  
Power  
consumption  
% of rated voltage  
75% max. 15% min.  
6
317  
158  
79  
18.90  
75  
Approx.1.90 W  
12  
24  
48  
100  
303  
40  
1,220  
5,260  
19  
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23°C (73°F) with tolerances of +15%/-20% for  
AC rated current and ±15% for DC coil resistance.  
2. Performance characteristic data are measured at a coil temperature of 23°C (73°F).  
CHARACTERISTICS  
Contact resistance  
Operate time  
50 mmax.  
30 ms max.  
Release time  
30 ms max.  
Max. operating  
frequency  
Mechanical  
Electrical  
1,800 operations/hour  
1,800 operations/hour (under rated load)  
1,000 Mmin. (at 500 VDC)  
Insulation resistance  
Dielectric strength  
4,000 VAC, min./5,000 VAC typical, 50/60 Hz for 1 minute between coil and contacts  
2,000 VAC, 50/60 Hz for 1 minute between contacts of same pole  
2,000 VAC, 50/60 Hz for 1 minute between contacts of different poles (DPST-NO type)  
Between coil and contact: 10,000 V (impulse wave used: 1.20 x 50 µs)  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
10 to 55 Hz; 1.50 mm (0.06 in) double amplitude  
1,000 m/s2 (approx. 100 G)  
Impulse withstand voltage  
Vibration  
Mechanical durability  
Malfunction durability  
Mechanical durability  
Malfunction durability  
Mechanical  
Shock  
1,000 m/s2 (approx.10 G)  
Life expectancy  
5,000,000 operations min. (at 1,800 operations/hour)  
100,000 operations min. (at 1,800 operations/hour under rated load)  
-20° to 85°C (-4° to 185°F)  
Electrical  
Ambient temperature  
Humidity  
35% to 85% RH  
Weight  
Quick-connect terminal type: approx. 90 g (3.17 oz)  
PCB terminal type: approx. 100 g (3.52 oz)  
Screw terminal type: approx. 120 g (4.23 oz)  
Note: Data shown are of initial value.  
3
G7L  
G7L  
CHARACTERISTIC DATA  
Maximum switching capacity  
Electrical service life  
Switching voltage (V)  
Switching current (A)  
Dimensions  
Unit: mm (inch)  
RELAYS  
G7L-1A-T  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-T  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
4
G7L  
G7L  
G7L-1A-TJ  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TJ  
(E Bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-TUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
5
G7L  
G7L  
Unit: mm (inch)  
RELAYS (continued)  
G7L-1A-TUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-TUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-B  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-B  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
6
G7L  
G7L  
G7L-1A-BJ  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BJ  
(E bracket Attached)*  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-BUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BUB  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
* E bracket must be ordered separately.  
7
G7L  
G7L  
Unit: mm (inch)  
RELAYS (continued)  
G7L-1A-BUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-BUBJ  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-1A-P  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
G7L-2A-P  
Terminal arrangement/  
Internal connections  
(Top view)  
Mounting holes  
(Bottom view)  
8
G7L  
G7L  
ACCESSORIES  
E bracket  
R99-07G5D  
Mounting holes  
(Bottom view)  
Adaptor  
P7LF-D  
Mounting holes  
(Bottom view)  
Front connecting socket  
P7LF-06  
Mounting holes  
(Bottom view)  
Note: 1. To protect against electric shock, use the P7LF-C cover on terminals.  
2. P7LF-C cover is supplied with P7LF-06 socket  
9
G7L  
G7L  
Unit: mm (inch)  
ACCESSORIES (continued)  
Cover  
P7LF-C  
Note: P7LF-C cover is supplied with P7LF-06 socket  
Mounting track  
PFP-100N, PFP-50N  
PFP-100N2  
Note: 1. It is recommended that a panel thickness of 1.60 to 2.00 mm (0.06 to 0.08 in) be used.  
2. L = Length  
PFP-100N ................. L = 1 m (39.00 in)  
PFP-50N ................. L = 50 cm (19.60 in)  
PFP-100N2 ............... L = 1 m (39.00 in)  
End plate  
PFP-M  
Spacer  
PFP-S  
10  
G7L  
G7L  
APPROVALS  
UL recognized type (File No. E41643)/ CSA certified type (File No. LR35535)  
Type  
Contact form  
SPST-NO  
Terminal type  
Quick-connect  
Contact ratings  
G7L-1A-T-CB  
G7L-1A-TJ-CB  
G7L-1A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-1A-B-CB  
G7L-1A-BJ-CB  
G7L-1A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-1A-P-CB  
30 A, 277 VAC (Resistive) 30,000 c  
30 A, 120 VAC (General purpose) 30,000 c  
30 A, 277 VAC (General purpose) 30,000 c  
1.5 kW, 120 VAC (Tungsten)  
Screw  
1.5 HP, 120 VAC  
3 HP, 240/265/277 VAC  
20 FLA/120 LRA, 120 VAC, 30,000 c  
17 FLA/102 LRA, 277 VAC, 30,000 c  
TV-10, 120 VAC  
PCB  
20 A (2.4 kW), 120 VAC (Tungsten)  
30 A, 277 VAC (Resistive) 30,000 c  
30 A, 120 VAC (General purpose) 30,000 c  
30 A, 277 VAC (General purpose) 30,000 c  
1.5 kW, 120 VAC (Tungsten)  
G7L-2A-T-CB  
DPST-NO  
Quick-connect  
G7L-2A-TJ-CB  
G7L-2A-TUB-CB  
G7L-2A-TUBJ-CB  
G7L-2A-B-CB  
Screw  
PCB  
1.5 HP, 120 VAC  
G7L-2A-BJ-CB  
G7L-2A-BUB-CB  
G7L-2A-BUBJ-CB  
G7L-2A-P-CB  
3 HP, 240/265/277 VAC  
20 FLA/120 LRA, 120 VAC, 30,000 c  
17 FLA/102 LRA, 277 VAC, 30,000 c  
TV-10, 120 VAC  
20 A (2.4 kW), 120 VAC (Tungsten)  
TÜV (File No. R9251551)  
Type  
Contact form  
SPST-NO  
Coil ratings  
6, 12, 24, 48,  
100, 110, 200,  
220 VDC  
Terminal type  
Quick-connect  
Contact ratings  
G7L-1A-T-CB  
G7L-1A-TJ-CB  
G7L-1A-TUB-CB  
G7L-1A-TUBJ-CB  
G7L-1A-B-CB  
G7L-1A-BJ-CB  
G7L-1A-BUB-CB  
G7L-1A-BUBJ-CB  
G7L-1A-P-CB  
25 A, 240 VAC, (cosϕ = 1)  
25 A, 240 VAC, (cosϕ = 0.4)  
12, 24, 50,  
100/120, 200/240  
VAC  
Screw  
30 A, 240 VAC, (cosϕ = 1)  
25 A, 240 VAC, (cosϕ = 0.4)  
30 A, 240 VAC, (cosϕ = 0.4)  
PCB  
20 A, 240 VAC, (cosϕ = 1)  
20 A, 240 VAC, (cosϕ = 0.4)  
25 A, 240 VAC, (cosϕ = 1)  
25 A, 240 VAC, (cosϕ = 0.4)  
G7L-2A-T-CB  
DPST-NO  
Quick-connect  
G7L-2A-TJ-CB  
G7L-2A-TUB-CB  
G7L-2A-TUBJ-CB  
G7L-2A-B-CB  
Screw  
PCB  
25 A, 240 VAC, (cosϕ = 1)  
25 A, 240 VAC, (cosϕ = 0.4)  
G7L-2A-BJ-CB  
G7L-2A-BUB-CB  
G7L-2A-BUBJ-CB  
G7L-2A-P-CB  
20 A, 240 VAC, (cosϕ = 1)  
20 A, 240 VAC, (cosϕ = 0.4)  
VDE recognized type (Licence no. 1530 UG)  
Note: 1. Please consult OMRON for details of VDE approvals.  
2. The G7L relay conforms to the following standards: Electrical safety: DIN IEC 255 Teil 1-00/DIN VDE 0435 Teil 201/05. 83  
DIN VDE 0435 Teil 201 A1/05. 90  
DIN IEC 255 Teil 0-20/DIN VDE 0435 Teil 120/10. 81  
DIN EN 60 950/VDE 0805/11. 93  
EMC:  
prEN 50082-2, EN 55022  
3. The rated values approved by each of the safety standards (e.g., UL and CSA) may be different from the performance  
characteristics individually defined in this catalog.  
4. In the interest of product improvement, specifications are subject to change.  
11  
G7L  
G7L  
Precautions  
HANDLING  
OPERATING COIL  
To preserve initial performance, do not drop or otherwise  
subject the power relay to shock.  
• As a rule, either a battery or a DC power supply with a  
maximum 5% ripple is used for the operating voltage for DC  
relays. Before using a rectified AC supply, confirm that the  
ripple is not greater than 5%. Ripple greater than this can  
lead to variations in the operating and reset voltages.  
• The case is not designed to be removed during normal  
handling and operation. Doing so may affect performance.  
• Use the power relay in a dry environment free from  
excessive dust, SO2, H2S, or organic gas.  
As excessive ripple can generate beats, the insertion of a  
smoothing capacitor is recommended as shown below.  
• Do not allow a voltage greater than the maximum allowable  
coil voltage to be applied continuously.  
• Do not use the power relay outside of specified voltages and  
currents.  
• Do not allow the ambient operating temperature to exceed  
the specified limit.  
INSTALLATION  
• Although there are not specific limits on the installation site,  
it should be as dry and dust-free as possible.  
• PCB terminal-equipped relays weigh approximately 100 g.  
Be sure that the PCB is strong enough to support them. We  
recommend dual-side through-hole PCBs to reduce solder  
cracking from heat stress.  
• Quick-connect terminals can be connected to fast on  
receptacle #250 and positive-lock connectors.  
• When driving a transistor, check the leakage current and  
connect a bleeder resistor if necessary.  
• Allow suitable slack on leads when wiring, and do not  
subject the terminals to excessive force.  
• Momentary voltage drops on coil input voltage should not  
exceed one second duration after contact mating with no  
shock or vibration.  
CLEANING PCB TERMINALS  
• PCB terminals have semi-sealed construction which  
prevents flux from entering the relay base. It is  
recommended that the user should apply a tape seal over  
the vent hole prior to wave soldering or cleaning. The tape  
should then be removed after processing.  
APPLICATIONS  
• Compressors for package air conditioners and heater  
switching controllers  
• Lamp control, motor drivers, and power supply switching in  
copy machines, facsimiles, and other OA equipment  
• Switching controllers for power tools or motors  
• Power controllers for water heaters  
• Power controllers for dryers  
• Lighting controllers  
• Power controllers for packers or food processing equipment  
• Magnetron control in microwaves  
OMRON ELECTRONICS, INC.  
One East Commerce Drive  
Schaumburg, IL 60173  
OMRON CANADA, INC.  
885 Milner Avenue  
Scarborough, Ontario M1B 5V8  
1-800-55-OMRON  
416-286-6465  
Cat. No. GC RLY7  
01/00  
Specifications subject to change without notice.  
Printed in the U.S.A.  
12