GT3A-5 [ETC]

Analog Timers;
GT3A-5
型号: GT3A-5
厂家: ETC    ETC
描述:

Analog Timers

文件: 总24页 (文件大小:2635K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
                                        
GT3A  
Timers  
GT3A  
GT3A Series — AnalogTimers  
Key features:  
•ꢀ 4ꢀselectableꢀoperationꢀmodesꢀonꢀeachꢀmodel  
•ꢀ Externalꢀstart,ꢀreset,ꢀandꢀgateꢀinputs  
•ꢀ Panelꢀmountꢀorꢀsocketꢀmount  
•ꢀ Largeꢀvarietyꢀofꢀtimingꢀfunctions  
•ꢀ PowerꢀandꢀoutputꢀstatusꢀindicatingꢀLEDs  
UL,ꢀc-ULꢀListed  
FileꢀNo.ꢀE55996  
ꢀꢀ ꢀꢀꢀꢀꢀꢀ  
Specifications  
GT3A-1  
GT3A-2  
GT3A-3  
GT3A-4,-5,-6  
Multi-modeꢀwithꢀinputsꢀ(11ꢀpins)  
Operation  
Multi-mode  
Time Range  
0.1sꢀtoꢀ180ꢀhours  
100ꢀtoꢀ240VꢀAC,ꢀ50/60Hz  
12VꢀDC  
Rated Voltage  
24VꢀAC,ꢀ50/60Hzꢀ/ꢀ24VꢀDC  
ꢀ125VꢀAC/250VꢀAC,ꢀ3A;ꢀ  
30VꢀDC,ꢀ1Aꢀ(resistiveꢀload)  
125VꢀAC/250VꢀAC,ꢀ5A;ꢀ  
30VꢀDC,ꢀ5Aꢀ(resistiveꢀload)  
Contact Ratings  
Minimum Applicable Load  
5V,ꢀ10mAꢀ(referenceꢀvalue)  
AF20ꢀ(100VꢀAC):ꢀ85ꢀtoꢀ264VꢀAC  
AD24:ꢀ20.4ꢀtoꢀ26.4VꢀAC/21.6ꢀtoꢀ26.4VꢀDC  
D12:ꢀ10.8ꢀtoꢀ13.2VꢀDC  
Voltage Tolerance  
Error  
±0.2%,ꢀ±10ꢀmsecꢀ(repeat,ꢀvoltage,ꢀtemperature)  
±10%ꢀmaximum  
Setting Error  
Reset Time  
60msecꢀmaximum  
Insulation Resistance  
100MWꢀminimum  
Betweenꢀpowerꢀandꢀoutputꢀterminals:ꢀ2,000VꢀAC,ꢀ1ꢀminute  
Betweenꢀcontactsꢀofꢀdifferentꢀpoles:ꢀ2,000VꢀAC,ꢀ1ꢀminute  
Betweenꢀcontactsꢀofꢀtheꢀsameꢀpole:ꢀ750VꢀAC,ꢀ1ꢀminute  
Dielectric Strength  
DelayedꢀSPDTꢀ+ꢀꢀ  
DelayedꢀDPDT  
DelayedꢀSPDT  
DelayedꢀDPDT  
instantaneousꢀSPDT  
10.8VA  
(200VꢀAC,ꢀ60Hz)  
13.5VA  
(200VꢀAC,ꢀ60Hz)  
14.4VA  
(200VꢀAC,ꢀ60Hz)  
4.7VAꢀ(100VꢀAC,ꢀ60Hz),ꢀ  
14.4VAꢀ(200VꢀAC,ꢀ60Hz)  
Power Consumption  
(approximate)  
12VDC/1W  
24VDC/0.7W  
24VAC/1.2VA  
12VDC/1.1W  
24VDC/0.6W  
24VAC/1.3VA  
12VDC/0.8W  
24VDC/0.6W  
24VAC/1.3VA  
Mechanical Life  
ꢀ10,000,000ꢀoperationsꢀminimum  
ꢀ50,000ꢀoperationsꢀminimumꢀ(ratedꢀload)  
63g 73g  
ꢀ5,000,000ꢀoperationsꢀminimum  
100,000ꢀoperationsꢀminimumꢀ(ratedꢀload)  
79g 80g  
Electrical LIfe  
Weight (approximate)  
Vibration Resistance  
100m/sec2ꢀ(approximateꢀ10G)  
Operatingꢀextremes:ꢀ100m/sec2ꢀ(approximateꢀ10G)  
Damageꢀlimits:ꢀ500m/sec2ꢀ(approximateꢀ50G)  
Shock Resistance  
Operating Temperature  
Operating Humidity  
Storage Temperature  
Housing Color  
–10ꢀtoꢀ+50°C  
45ꢀtoꢀ85%ꢀRH  
–30ꢀtoꢀ+80°C  
Gray  
800-262-IDEC (4332) USA & Canada  
843  
GT3A  
Timers  
Part Numbers  
GT3A-1, -2, -3  
Complete Part No.  
Mode Of  
Operation  
Rated Voltage Code  
Time Range  
Output  
Contact  
8-Pin  
11-Pin  
AF20:ꢀ100ꢀtoꢀ240VꢀACꢀ(50/60Hz)  
DelayedꢀSPDT  
GT3A-1AF20  
GT3A-2AF20  
GT3A-2D12  
GT3A-2AD24  
GT3A-3AF20  
GT3A-3D12  
GT3A-3AD24  
GT3A-1EAF20  
GT3A-2EAF20  
GT3A-2ED12  
GT3A-2EAD24  
GT3A-3EAF20  
GT3A-3ED12  
GT3A-3EAD24  
250VꢀAC,ꢀ3A,  
30VꢀDC,ꢀ1A  
(resistiveꢀload)  
DelayedꢀSPDTꢀ+  
InstantaneousꢀSPDT  
A:ꢀON-delayꢀ1  
B:ꢀIntervalꢀ1  
C:ꢀCycleꢀ1  
D:ꢀCycleꢀ3  
0.1ꢀsecondsꢀꢀ  
toꢀ180ꢀhoursꢀ  
AF20:ꢀ100ꢀtoꢀ240VꢀACꢀ(50/60Hz)  
D12:ꢀ12VꢀDC  
AD24:ꢀ24VꢀACꢀ(50/60Hz)/24VꢀDC  
240VꢀAC,ꢀ5A,  
24VꢀDC,ꢀ5A  
(resistiveꢀload)  
DelayedꢀDPDT  
1.ꢀ ForꢀwiringꢀschematicsꢀandꢀtimingꢀdiagramsꢀforꢀGT3A-1,ꢀ-2,ꢀ-3,ꢀseeꢀpagesꢀpageꢀ845ꢀandꢀpageꢀ846ꢀrespectively.  
2.ꢀ Forꢀmoreꢀdetailsꢀaboutꢀtimeꢀranges,ꢀseeꢀinstructionsꢀonꢀpageꢀpageꢀ850.  
3.ꢀ Forꢀsocketꢀandꢀaccessoryꢀpartꢀnumbers,ꢀseeꢀpageꢀ860.  
GT3A-4, -5, -6  
Complete Part No.  
Mode of  
Operation  
Rated Voltage Code  
Time Range  
Output  
Contact  
Input  
A (11-pin)  
B (11-pin)  
GT3A-4AF20  
GT3A-4EAF20  
A:ꢀON-Delayꢀ2  
B:ꢀCycleꢀ2  
C:ꢀSignalꢀON/OFF-Delayꢀ1  
D:ꢀSignalꢀOFF-Delayꢀ1  
AF20:ꢀ100ꢀtoꢀ240VꢀACꢀ(50/60Hz)  
D12:ꢀ12VꢀDC  
AD24:ꢀ24VꢀACꢀ(50/60Hz)/24VꢀDC  
GT3A-4D12  
GT3A-4ED12  
GT3A-4AD24  
GT3A-4EAD24  
A:ꢀIntervalꢀ2  
GT3A-5AF20  
GT3A-5AD24  
GT3A-6AF20  
GT3A-6AD24  
GT3A-5EAF20  
GT3A-5EAD24  
GT3A-6EAF20  
GT3A-6EAD24  
250VꢀAC,ꢀ5A,  
24VꢀDC,ꢀ5A  
(resistiveꢀload)  
Start  
Reset  
Gate  
0.1ꢀseconds  
toꢀ180ꢀhours  
Delayedꢀ  
DPDT  
B:ꢀOne-ShotꢀCycle  
C:ꢀSignalꢀON/OFF-Delayꢀ2  
D:ꢀSignalꢀOFF-Delayꢀ2  
AF20:ꢀ100ꢀtoꢀ240VꢀACꢀ(50/60Hz)  
AD24:ꢀ24VꢀACꢀ(50/60Hz)/24VꢀDC  
A:ꢀOne-Shot  
B:ꢀOne-ShotꢀON-Delay  
C:ꢀOne-Shotꢀ2  
D:ꢀSignalꢀON/OFF-Delayꢀ3  
4.ꢀ ForꢀwiringꢀschematicsꢀandꢀtimingꢀdiagramsꢀGT3A-4,-5,-6,ꢀseeꢀpagesꢀ832,ꢀ833,ꢀandꢀ833ꢀrespectively.  
5.ꢀ Forꢀmoreꢀdetailsꢀaboutꢀtimeꢀranges,ꢀseeꢀinstructionsꢀonꢀpageꢀ850.  
6.ꢀ Aꢀ(11-pin)ꢀandꢀBꢀ(11-pin)ꢀdifferꢀinꢀtheꢀwayꢀinputsꢀareꢀwired.  
7.ꢀ Forꢀsocketꢀandꢀaccessoryꢀpartꢀnumbers,ꢀseeꢀpageꢀ860.  
8.ꢀ Forꢀtheꢀtimingꢀdiagramsꢀoverview,ꢀseeꢀpageꢀ832.  
www.IDEC.com  
844  
GT3A  
Timers  
Timing Diagrams/Schematics  
GT3A-1 Timing Diagrams  
Delayed SPDT  
Operation  
Mode  
Selection  
Item  
SetꢀTime  
Terminal Number  
Operation  
ON-Delay 1  
MODE  
A
T
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Power  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
OUT  
Item  
SetꢀTime  
Terminal Number  
Operation  
Operation  
Operation  
Interval 1  
MODE  
B
T
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Power  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
(NC)  
Delayedꢀ  
Contact  
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
(NO)  
POWER  
Indicator  
OUT  
Cycle 1  
(OFFꢀfirst)ꢀ  
Item  
SetꢀTime  
Terminal Number  
T
T
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Power  
MODE  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
(NC)  
Delayedꢀ  
Contact  
C
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
(NO)  
POWER  
Indicator  
OUT  
Cycle 3  
(ONꢀfirst)ꢀ  
Item  
SetꢀTime  
Terminal Number  
T
T
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Power  
MODE  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
(NC)  
Delayedꢀ  
Contact  
D
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
(NO)  
POWER  
Indicator  
OUT  
800-262-IDEC (4332) USA & Canada  
845  
GT3A  
Timers  
GT3A-2 Timing Diagrams  
Delayed SPDT + Instantaneous SPDT  
GT3A-3 Timing Diagrams  
Delayed DPDT  
Operation  
Mode  
Selection  
Operation  
Mode  
Selection  
Item  
SetꢀTime  
Terminal Number  
Operation  
Operation  
Operation  
Operation  
Item  
SetꢀTime  
Terminal Number  
Operation  
ON-Delay 1  
MODE  
A
T
T
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
ON-Delay 1  
MODE  
A
Power  
Power  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
1ꢀ-4,ꢀ5ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-4,ꢀ8ꢀ-ꢀ11ꢀ(11p)  
1ꢀ-3,ꢀ6ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-3,ꢀ9ꢀ-ꢀ11ꢀ(11p)  
(NC)  
(NC)  
(NO)  
Delayedꢀ  
Contact  
Delayedꢀ  
Contact  
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
(NO)  
1ꢀ-ꢀ4  
(NC)  
(NO)  
POWER  
Instantaneousꢀ  
Contact  
Indicator  
1ꢀ-ꢀ3  
OUT  
POWER  
OUT  
Indicator  
Item  
SetꢀTime  
Terminal Number  
Operation  
Interval 1  
MODE  
B
T
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Power  
Item  
SetꢀTime  
Terminal Number  
1ꢀ-4,ꢀ5ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-4,ꢀ8ꢀ-ꢀ11ꢀ(11p)  
(NC)  
T
Delayedꢀ  
Contact  
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
1ꢀ-3,ꢀ6ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-3,ꢀ9ꢀ-ꢀ11ꢀ(11p)  
Interval 1  
MODE  
B
Power  
(NO)  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
(NC)  
POWER  
Delayedꢀ  
Contact  
Indicator  
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
(NO)  
OUT  
1ꢀ-ꢀ4  
(NC)  
(NO)  
Instantaneousꢀ  
Contact  
1ꢀ-ꢀ3  
Cycle 1  
(OFFꢀfirst)ꢀ  
Item  
SetꢀTime  
Terminal Number  
Operation  
T
T
POWER  
OUT  
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Indicator  
Power  
MODE  
1ꢀ-4,ꢀ5ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-4,ꢀ8ꢀ-ꢀ11ꢀ(11p)  
(NC)  
Delayedꢀ  
Contact  
1ꢀ-3,ꢀ6ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-3,ꢀ9ꢀ-ꢀ11ꢀ(11p)  
C
(NO)  
Item  
SetꢀTime  
Terminal Number  
POWER  
T
T
Cycle 1  
(OFFꢀfirst)ꢀ  
Indicator  
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Power  
OUT  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
(NC)  
Delayedꢀ  
Contact  
MODE  
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
(NO)  
Cycle 3  
(ONꢀfirst)ꢀ  
Item  
SetꢀTime  
Terminal Number  
Operation  
C
1ꢀ-ꢀ4  
(NC)  
(NO)  
Instantaneousꢀ  
Contact  
T
T
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
1ꢀ-ꢀ3  
Power  
MODE  
1ꢀ-4,ꢀ5ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-4,ꢀ8ꢀ-ꢀ11ꢀ(11p)  
POWER  
OUT  
(NC)  
Delayedꢀ  
Contact  
Indicator  
1ꢀ-3,ꢀ6ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-3,ꢀ9ꢀ-ꢀ11ꢀ(11p)  
D
(NO)  
POWER  
Indicator  
OUT  
Item  
Terminal Number  
SetꢀTime  
T
T
Cycle 3  
(ONꢀfirst)ꢀ  
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
5ꢀ-ꢀ8ꢀ(8p)  
8ꢀ-ꢀ11ꢀ(11p)  
6ꢀ-ꢀ8ꢀ(8p)  
9ꢀ-ꢀ11ꢀ(11p)  
Power  
(NC)  
Delayedꢀ  
Contact  
MODE  
(NO)  
D
1ꢀ-ꢀ4  
(NC)  
(NO)  
Instantaneousꢀ  
Contact  
1ꢀ-ꢀ3  
POWER  
OUT  
Indicator  
Note:ꢀPinsꢀ1,ꢀ3,ꢀandꢀ4ꢀareꢀtheꢀinstantaneousꢀcontacts.  
www.IDEC.com  
846 ꢀ  
GT3A  
Timers  
GT3A-4 Timing Diagrams  
Delayed DPDT  
Operation  
Mode Selection  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
ON-Delay 2  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
A
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
Ta  
T'  
T"  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
Cycle 2  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
B
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
T
T
T
T
T
T
Ta  
T
T
T
T"  
T"  
T
T
T
T
T
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
Signal ON/OFF-Delay 1  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
C
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
T
Ta  
T
Ta  
T
T
T
T"  
Ta  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
Signal OFF-Delay 1  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
D
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
Ta  
Ta  
T
T
T
Tꢀ=ꢀSetꢀtimeꢀ Taꢀ=ꢀShorterꢀthanꢀsetꢀtime  
Tꢀ=ꢀT'ꢀ+ꢀT"  
800-262-IDEC (4332) USA & Canada  
847  
GT3A  
Timers  
GT3A-5 Timing Diagrams  
Delayed DPDT  
Operation  
Mode Selection  
Item  
Power  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
Interval 2  
MODE  
A
Input  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
Ta  
T'  
T"  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
One-Shot Cycle  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
B
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
T
T
Ta  
T'  
T"  
T
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
Signal ON/OFF-Delay 2  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
C
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
T
Ta  
T
Ta  
Operation  
Ta  
T
T'  
T"  
Ta  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
Signal OFF-Delay 2  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
D
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
Ta  
Ta  
T
T'  
T"  
Tꢀ=ꢀSetꢀtimeꢀ Taꢀ=ꢀShorterꢀthanꢀsetꢀtime  
Tꢀ=ꢀT'ꢀ+ꢀT"  
www.IDEC.com  
848 ꢀ  
GT3A  
Timers  
GT3A-6 Timing Diagrams  
Delayed DPDT  
Operation  
Mode Selection  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
One-Shot 1  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
A
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
Ta  
Ta  
T
Ta  
T'  
T"  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
One-Shot ON-Delay  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
B
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
T
Ta  
T
T
T
T
T'  
T"  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
One-Shot 2  
MODE  
C
Input  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
Ta  
T'  
T"  
Item  
Terminal Number  
2ꢀ-ꢀ10ꢀPOWER  
Operation  
Power  
2ꢀ-ꢀ6ꢀ(A)  
5ꢀ-ꢀ7ꢀ(B)  
2ꢀ-ꢀ7ꢀ(A)  
6ꢀ-ꢀ7ꢀ(B)  
Start  
Reset  
Gate  
ONꢀorꢀL  
ONꢀorꢀL  
Signal ON/OFF-Delay 3  
Input  
MODE  
2ꢀ-ꢀ5ꢀ(A) ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
D
(NC)  
(NO)  
Delayedꢀ  
Contact  
POWER  
Indicator  
SetꢀTime  
OUT  
T
Ta  
T'  
T"  
Ta  
Ta  
T
Tꢀ=ꢀSetꢀtimeꢀ Taꢀ=ꢀShorterꢀthanꢀsetꢀtime  
Tꢀ=ꢀT'ꢀ+ꢀT"  
800-262-IDEC (4332) USA & Canada  
849  
GT3A  
Timers  
Instructions: Setting GT3A SeriesTimers  
ꢀ TimedꢀOUTꢀIndicatorꢀ  
ꢀ POWERꢀIndicatorꢀ(flashesꢀ  
duringꢀtime-delayꢀperiod)  
mSettingꢀKnob  
jOperatorꢀModeꢀSelectorꢀ  
A,ꢀB,ꢀC,ꢀD  
lTimeꢀRangeꢀSelectorꢀꢀ  
1S,ꢀ10S,ꢀ10M,ꢀ10H  
kDialꢀSelectorꢀ  
0-1, 0-3, 0-6, 0-18  
Step 1.  
Desired Mode of Operation  
Selection  
Remarks  
For Timers  
Mode of Operation  
ON-delayꢀ1  
Intervalꢀ1  
Cycleꢀ1  
Cycleꢀ3  
j Operation Mode Selector  
A
B
C
D
GT3A-1  
GT3A-2  
GT3A-3  
ON-delayꢀ2  
Cycleꢀ2  
A
B
C
D
A
B
C
D
Theꢀdesiredꢀoperationꢀmodeꢀcanꢀbeꢀselectedꢀfromꢀ  
theꢀA,ꢀB,ꢀC,ꢀandꢀDꢀmodesꢀusingꢀtheꢀOperationꢀModeꢀ  
Selector.ꢀChangeꢀtheꢀoperationꢀmodeꢀfromꢀAꢀtoꢀB,ꢀC,ꢀ  
andꢀDꢀinꢀturnꢀbyꢀturningꢀtheꢀoperationꢀmodeꢀselectorꢀ  
clockwiseꢀusingꢀaꢀflatꢀscrewdriverꢀwhichꢀisꢀaꢀmaximumꢀ  
ofꢀ0.156”ꢀ(4mm)ꢀwide.ꢀTheꢀselectedꢀmodeꢀisꢀdisplayedꢀ  
inꢀtheꢀwindow.  
GT3A-4  
GT3A-5  
GT3A-6  
SignalꢀON/OFF-delayꢀ1  
SignalꢀOFF-delayꢀ1  
Intervalꢀ2  
One-shotꢀcycle  
SignalꢀON/OFF-delayꢀ2  
SignalꢀOFF-delayꢀ2  
One-shotꢀ1  
Selectꢀtheꢀdesiredꢀmodeꢀ  
ofꢀoperation.ꢀ  
A
One-shotꢀON-delay  
One-shotꢀ2  
SignalꢀON/OFF-delayꢀ3  
B
C
D
Step 2.  
Desired Time Range  
Time Ranges  
Selection  
Remarks  
k Dial Selector  
l Time Range Selector  
0.1ꢀsecondsꢀtoꢀ1ꢀsecond  
0.1ꢀsecondsꢀtoꢀ3ꢀseconds  
0.1ꢀsecondsꢀtoꢀ6ꢀseconds  
0.15ꢀsecondsꢀtoꢀ18ꢀseconds  
0.1ꢀsecondsꢀtoꢀ10ꢀseconds  
0.3ꢀsecondsꢀtoꢀ30ꢀseconds  
0.6ꢀsecondsꢀtoꢀ60ꢀseconds  
1.8ꢀsecondsꢀtoꢀ180ꢀseconds  
6ꢀsecondsꢀtoꢀ10ꢀminutes  
18ꢀsecondsꢀtoꢀ30ꢀminutes  
36ꢀsecondsꢀtoꢀ60ꢀminutes  
108ꢀsecondsꢀtoꢀ180ꢀminutes  
6ꢀminutesꢀtoꢀ10ꢀhours  
0-1  
0-3  
0-6  
0-18  
0-1  
0-3  
0-6  
0-18  
0-1  
0-3  
0-6  
1S  
10S  
Selectꢀtheꢀtimeꢀrangeꢀ  
thatꢀcontainsꢀtheꢀdesiredꢀ  
timeꢀperiod.  
Theꢀdesiredꢀtimeꢀrangeꢀisꢀselectedꢀbyꢀsettingꢀbothꢀ  
kꢀDialꢀSelectorꢀandꢀ  
lꢀTimeꢀRangeꢀSelector.  
10M  
0-18  
0-1  
18ꢀminutesꢀtoꢀ30ꢀhours  
36ꢀminutesꢀtoꢀ60ꢀhours  
0-3  
0-6  
10H  
108ꢀminutesꢀtoꢀ180ꢀhours  
0-18  
Step 3.  
Selection  
SetꢀtheꢀpreciseꢀperiodꢀofꢀtimeꢀdesiredꢀbyꢀusingꢀtheꢀmꢀSettingꢀKnob.  
www.IDEC.com  
850 ꢀ  
GT3F  
Timers  
GT3F Series True Power OFF DelayTimers  
Key features:  
•ꢀ “True”ꢀpowerꢀOFF-delayꢀupꢀtoꢀ10ꢀminutes  
•ꢀ Noꢀexternalꢀcontrolꢀswitchꢀnecessary  
•ꢀ Availableꢀwithꢀresetꢀinputs  
•ꢀ Mountableꢀinꢀsocketsꢀorꢀflushꢀpanel  
UL,ꢀc-ULꢀListed  
FileꢀNo.ꢀE55996  
ꢀꢀ ꢀꢀꢀꢀꢀꢀ  
Specifications  
GT3F-1  
GT3F-2  
Operation  
TrueꢀpowerꢀOFF-delay  
Time Range  
ꢀ0.1ꢀsecondsꢀtoꢀ600ꢀseconds  
100ꢀtoꢀ240VꢀAC,ꢀ50/60Hz  
24VꢀAC/DC  
Rated Voltage  
250VꢀAC/30VꢀDC,ꢀ5Aꢀ  
(resistiveꢀload)  
250VꢀAC/30VꢀDC,ꢀ3A  
(resistiveꢀload)  
Contact Rating  
Contact Form  
SPDT  
DPDT  
Minimum Power Application Time  
ꢀ1ꢀsecond  
AF20:ꢀ100ꢀtoꢀ240VꢀAC  
AD24:ꢀ21.6ꢀtoꢀ26.4VDC,ꢀ20.4ꢀtoꢀ26.4VAC  
Voltage Tolerance  
Repeat Error  
±0.2%,ꢀ±10ꢀmsec  
±0.2%,ꢀ±10ꢀmsec  
±0.2%,ꢀ±10ꢀmsec  
±10%ꢀmaximum  
100MWꢀminimum  
Voltage Error  
Temperature Error  
Setting Error  
Insulation Resistance  
Betweenꢀpowerꢀandꢀoutputꢀterminals:  
2,000VꢀAC,ꢀ1ꢀminuteꢀ(SPDT)  
1,500VꢀAC,ꢀ1ꢀminuteꢀ(DPDT)  
Betweenꢀcontactsꢀonꢀdifferentꢀpoles:  
1,000VꢀAC,ꢀ1ꢀminuteꢀ(DPDT)  
Betweenꢀcontactsꢀofꢀtheꢀsameꢀpole:  
750VꢀAC,ꢀ1ꢀminute  
Dielectric Strength  
Power Consumption  
AF20:ꢀ3.7VAꢀ(200VꢀAC,ꢀ60Hz)  
AD24:ꢀ0.8Wꢀ(DC),ꢀ1.2VAꢀ(AC)  
Mechanical Life  
Electrical Life  
20,000,000ꢀoperationsꢀminimum  
100,000ꢀoperationsꢀminimum  
100m/sec2ꢀ(approximateꢀ10G)  
Vibration Resistance  
Operatingꢀextremes:  
100ꢀm/sec2ꢀ(approximateꢀ10G)  
Shock Resistance  
Damageꢀlimits:ꢀ500ꢀm/sec2ꢀ(approximateꢀ50G)  
Operating Temperature  
Storage Temperature  
Operating Humidity  
–10ꢀtoꢀ+50°C  
–30ꢀtoꢀ+80°C  
45ꢀtoꢀ85%ꢀRH  
Weight (approximate)  
ꢀ77g  
79g  
1.ꢀ Anꢀinrushꢀcurrentꢀflowsꢀduringꢀtheꢀminimumꢀpowerꢀapplicationꢀtime.ꢀAF20:ꢀapproximateꢀ0.4A,ꢀꢀ  
AD24:ꢀapproximateꢀ1.2A  
2.ꢀ GT3Fꢀdoesꢀnotꢀreadꢀtheꢀpresetꢀtimeꢀrangeꢀshownꢀonꢀtheꢀknobꢀafterꢀpowerꢀisꢀturnedꢀoff.ꢀNoteꢀthatꢀminimizingꢀ  
theꢀpresetꢀtime,ꢀbyꢀturningꢀtheꢀknobꢀtoꢀzero,ꢀdoesꢀnotꢀshortenꢀtheꢀdelayꢀtimeꢀafterꢀpowerꢀisꢀremoved.  
800-262-IDEC (4332) USA & Canada  
851  
GT3F  
Timers  
Part Numbering List  
GT3F  
Complete Part Number  
Mode of  
Operation  
Rated  
Voltage Code  
Time Range  
Output  
250VꢀAC,ꢀ5A,  
Contact  
DelayedꢀSPDT  
DelayedꢀDPDT  
Optional Input  
8-Pin  
11-Pin  
GT3F-1AF20  
GT3F-1AD24  
GT3F-2AF20  
GT3F-2AD24  
GT3F-1EAF20  
GT3F-1EAD24  
GT3F-2EAF20  
GT3F-2EAD24  
AF20:ꢀ100ꢀtoꢀ  
240VACꢀ(50/60Hz)  
Reset  
30VꢀDC,ꢀ5Aꢀ(resistiveꢀload)  
250VꢀAC,ꢀ3A,  
True-Powerꢀꢀ  
OFF-delay  
0.1ꢀsecondsꢀtoꢀ  
600ꢀseconds  
Noneꢀ(8p)ꢀ  
Resetꢀ(11p)  
AD24:ꢀ24VꢀAC/DC  
30VꢀDC,ꢀ3Aꢀ(resistiveꢀload)  
ꢀOptionalꢀresetꢀinputꢀresetsꢀtheꢀcontactꢀtoꢀtheꢀOFFꢀstateꢀbeforeꢀtimeꢀout.  
Timing Diagrams/Schematics  
GT3F-1 Timing Diagrams  
GT3F-1 (8-pin)  
GT3F-1E (11-pin)  
Delayed SPDT Output, with Reset Input  
Item  
Power  
Terminal Number  
2ꢀ-ꢀ7ꢀ(8p)  
2ꢀ-ꢀ10ꢀ(11p)  
Operation  
Resetꢀ  
Input  
1ꢀ-ꢀ4ꢀ(8p)  
6ꢀ-ꢀ7ꢀ(11p)  
5ꢀ-ꢀ8ꢀ(8p)  
ONꢀorꢀL  
(NC)  
1ꢀ-ꢀ4ꢀ(11p)  
Delayedꢀ  
Contact  
6ꢀ-ꢀ8ꢀ(8p)  
1ꢀ-ꢀ3ꢀ(11p)  
(NO)  
Indicator POWER  
SetꢀTime  
Tr  
T
Ta  
Ts  
T
Tꢀ=ꢀSetꢀtimeꢀ  
Taꢀ=ꢀShorterꢀthanꢀsetꢀtime  
Tsꢀ=ꢀ1ꢀSecond  
Trꢀ=ꢀMinimumꢀPowerꢀApplicationꢀTime  
GT3F-1:ꢀ1ꢀSecond  
1.ꢀ Forꢀtimeꢀranges,ꢀseeꢀpageꢀpageꢀ854.  
2.ꢀ Forꢀsocketsꢀandꢀaccessoryꢀpartꢀnumbers,ꢀseeꢀpageꢀpageꢀ860.  
3.ꢀ Whenꢀpowerꢀisꢀapplied,ꢀtheꢀNOꢀoutputꢀcontactꢀcloses.ꢀWhenꢀpowerꢀisꢀremoved,ꢀtheꢀtimingꢀperiodꢀ  
begins.ꢀWhenꢀtimeꢀhasꢀelapsed,ꢀtheꢀNOꢀcontactꢀopens.ꢀ  
4.ꢀ Forꢀtheꢀtimingꢀdiagramꢀoverview,ꢀseeꢀpageꢀpageꢀ832.  
www.IDEC.com  
852  
GT3F  
Timers  
GT3F-2 Timing Diagrams  
GT3F-2 (8-pin)  
GT3F-2E (11-pin)  
Delayed DPDT Output  
(Contact Input)  
(Transistor Input)  
o
o
m
n
q
p
p
n
n
Reset  
q
q
m
l
m
l
l
o
Reset  
r
r
(-) k  
p (+)  
s
s
(-) k  
(-) k  
(+)  
(+)  
j
j
j
POWER  
POWER  
POWER  
Item  
Terminal Number  
2ꢀ-ꢀ7  
1ꢀ-ꢀ4ꢀ  
Operation  
Power  
(NC)  
5ꢀ-ꢀ8  
Delayedꢀ  
Contact  
1ꢀ-ꢀ3ꢀ  
6ꢀ-ꢀ8  
8-Pin Type  
(NO)  
Indicator POWER  
SetꢀTime  
T
Tr  
T
Item  
Power  
Terminal Number  
Operation  
2ꢀ-ꢀ10  
Resetꢀ  
Input  
6ꢀ-ꢀ7ꢀ(11p)  
ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
(NC)  
(NO)  
Delayedꢀ  
Contact  
11-Pin Type  
Indicator POWER  
SetꢀTime  
Tr  
T
Ta  
Ts  
T
Whenꢀpowerꢀisꢀapplied,ꢀtheꢀNOꢀcontactꢀcloses.ꢀWhenꢀpowerꢀisꢀremoved,ꢀtheꢀtimingꢀperiodꢀbegins.ꢀWhenꢀtimeꢀhasꢀelapsed,ꢀtheꢀNOꢀcontactꢀopens.ꢀOptionalꢀresetꢀ  
inputꢀwillꢀreturnꢀcontactsꢀtoꢀoriginalꢀstateꢀbeforeꢀtimeꢀelapses.  
Tꢀ=ꢀSetꢀtimeꢀ  
Taꢀ=ꢀShorterꢀthanꢀsetꢀtime  
Tsꢀ=ꢀ1ꢀSecond  
Trꢀ=ꢀMinimumꢀPowerꢀApplicationꢀTime  
GT3F-1:ꢀ1ꢀSecond  
Item  
Power  
Terminal Number  
Operation  
2ꢀ-ꢀ10  
Resetꢀ  
Input  
6ꢀ-ꢀ7ꢀ(11p)  
ONꢀorꢀL  
1ꢀ-ꢀ4  
8ꢀ-ꢀ11  
(NC)  
(NO)  
Delayedꢀ  
Contact  
1ꢀ-ꢀ3  
9ꢀ-ꢀ11  
Indicator POWER  
SetꢀTime  
Tr  
T
Ta  
Ts  
T
800-262-IDEC (4332) USA & Canada  
853  
GT3F  
Timers  
Instructions: Setting GT3F SeriesTimers  
ꢀ POWERꢀIndicatorꢀ  
lSettingꢀKnob  
jDialꢀSelectorꢀ  
0-1,ꢀ0-3,ꢀ0-6,ꢀ0-18,ꢀ0-60  
kTimeꢀRangeꢀSelectorꢀꢀ  
1S,ꢀ10S  
Step 1  
Desired Operation  
Selection  
k Time Range Selector  
Remarks  
Base Time Ranges  
0.1sꢀtoꢀ1s  
j Dial Selector  
0ꢀtoꢀ1  
0.1sꢀtoꢀ3s  
0ꢀtoꢀ3  
1s  
Selectꢀaꢀtimeꢀ  
rangeꢀthatꢀ  
Timeꢀrangeꢀcanꢀbeꢀselectedꢀfromꢀ1Sꢀandꢀ10Sꢀusingꢀaꢀflatꢀscrewdriverꢀandꢀfiveꢀ  
differentꢀdialsꢀofꢀ0ꢀtoꢀ1,ꢀ0ꢀtoꢀ3,ꢀ0ꢀtoꢀ6,ꢀ0ꢀtoꢀ18,ꢀandꢀ0ꢀtoꢀ60ꢀareꢀdisplayedꢀinꢀtheꢀsixꢀ  
windowsꢀbyꢀturningꢀtheꢀDialꢀSelector,ꢀallowingꢀforꢀselectingꢀtheꢀbestꢀsuitedꢀscale.ꢀ  
Noteꢀthatꢀtheꢀswitchꢀdoesꢀnotꢀturnꢀinfinitely.  
0.1sꢀtoꢀ6s  
0ꢀtoꢀ6  
containsꢀtheꢀ  
desiredꢀperiodꢀ  
ofꢀtime.  
0.1sꢀtoꢀ10s  
0.3sꢀtoꢀ30  
0ꢀtoꢀ1  
0ꢀtoꢀ3  
0.6sꢀtoꢀ60  
0ꢀtoꢀ6  
10s  
1.8sꢀtoꢀ180s  
6sꢀtoꢀ600s  
0ꢀtoꢀ18  
0ꢀtoꢀ60  
Step 2  
Remarks  
SettingꢀExamples:  
1.ꢀWhenꢀtheꢀSettingꢀKnobꢀlꢀisꢀsetꢀatꢀ2.5,ꢀwithꢀDialꢀSelectorꢀjꢀ0ꢀtoꢀ3ꢀandꢀTimeꢀ  
RangeꢀSelectorꢀkꢀ1Sꢀselected,ꢀthenꢀtheꢀsetꢀtimeꢀisꢀ2.5ꢀseconds.  
TheꢀsetꢀtimeꢀisꢀselectedꢀbyꢀturningꢀtheꢀlꢀSettingꢀKnob.  
2.ꢀWhenꢀtheꢀSettingꢀKnobꢀlꢀisꢀsetꢀatꢀ5.0,ꢀ  
withꢀDialꢀSelectorꢀjꢀ0ꢀtoꢀ60ꢀandꢀTimeꢀRangeꢀSelectorꢀkꢀ10Sꢀselected,ꢀthenꢀtheꢀ  
setꢀtimeꢀisꢀ500ꢀseconds.  
www.IDEC.com  
854 ꢀ  
GT3F  
Timers  
Instructions:Wiring Inputs  
Inputs of GT3F  
Toꢀavoidꢀelectricꢀshock,ꢀdoꢀnotꢀtouchꢀtheꢀinputꢀsignalꢀterminalꢀduringꢀpowerꢀvoltageꢀapplication.ꢀꢀ  
NeverꢀapplyꢀtheꢀinputꢀsignalsꢀtoꢀtwoꢀorꢀmoreꢀGT3Fꢀtimersꢀusingꢀtheꢀsameꢀcontactꢀorꢀtransistor.  
[Incorrect]  
Input  
Contact or Transistor  
GT3 Series  
Timer  
[correct]  
Input  
Input  
Terminal  
Terminal  
2
2
10  
10  
2
10  
Power  
Power  
Input  
Terminal  
Input  
Terminal  
2
10  
ꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀꢀ  
Inꢀaꢀtransistorꢀcircuitꢀforꢀcontrollingꢀinputꢀsignals,ꢀwithꢀitsꢀprimaryꢀandꢀsecondaryꢀpowerꢀcircuitsꢀisolated,ꢀdoꢀnotꢀgroundꢀtheꢀsecondaryꢀcircuit.  
GT3 Series  
Timer  
Input  
Terminal  
Power  
Circuit  
Insulating Transformer  
OnꢀtheꢀGT3Fꢀtimers,ꢀconnectꢀtheꢀinputꢀsignalsꢀtoꢀterminalꢀNo.1ꢀandꢀ4ꢀonlyꢀonꢀtheꢀ8-pinꢀtype;ꢀconnectꢀtheꢀinputꢀsignalsꢀtoꢀterminalꢀNo.ꢀ6ꢀandꢀ7ꢀonlyꢀonꢀtheꢀ11-pinꢀtype.ꢀ  
Neverꢀapplyꢀvoltageꢀtoꢀotherꢀterminals;ꢀotherwise,ꢀtheꢀinternalꢀcircuitꢀmayꢀbeꢀdamaged.  
Inputꢀsignalꢀlinesꢀmustꢀbeꢀmadeꢀasꢀshortꢀasꢀpossibleꢀandꢀinstalledꢀawayꢀfromꢀpowerꢀcablesꢀandꢀpowerꢀlines.ꢀUseꢀshieldedꢀwiresꢀorꢀaꢀseparateꢀconduitꢀforꢀinputꢀwir-  
ing.ꢀ  
TheꢀGT3F,ꢀconsistingꢀofꢀaꢀhigh-impedanceꢀcircuit,ꢀmayꢀnotꢀbeꢀresetꢀdueꢀtoꢀtheꢀinfluenceꢀofꢀanꢀinductiveꢀvoltageꢀorꢀresidualꢀvoltageꢀcausedꢀbyꢀaꢀleakageꢀcurrent.ꢀIfꢀnotꢀ  
reset,ꢀconnectꢀanꢀRCꢀfilterꢀorꢀbleederꢀresistorꢀbetweenꢀpowerꢀterminalsꢀsoꢀthatꢀtheꢀvoltageꢀbetweenꢀpowerꢀterminalsꢀcanꢀbeꢀreducedꢀtoꢀlessꢀthanꢀ15%ꢀofꢀtheꢀratedꢀ  
voltage.  
800-262-IDEC (4332) USA & Canada  
855  
GT3W  
Timers  
GT3W Series — DualTime RangeTimers  
Key features:  
•ꢀ Sequentialꢀstart,ꢀsequentialꢀinterval,ꢀon-delay,ꢀrecycler,ꢀꢀ  
andꢀintervalꢀONꢀtimingꢀfunctions  
•ꢀ 2ꢀtimeꢀsettingsꢀinꢀoneꢀtimer  
•ꢀ 8ꢀselectableꢀoperationꢀmodesꢀonꢀeachꢀmodel  
•ꢀ Mountableꢀinꢀsocketsꢀorꢀflushꢀpanel  
•ꢀ PowerꢀandꢀoutputꢀstatusꢀindicatingꢀLEDs  
•ꢀ Timeꢀrangesꢀupꢀtoꢀ300ꢀhours  
UL,ꢀc-ULꢀListed  
FileꢀNo.ꢀE55996  
ꢀꢀ ꢀꢀꢀꢀꢀꢀ  
General Specifications  
Operation System  
Contact Ratings  
Allowable Contact Power  
Allowable Voltage  
SolidꢀstateꢀCMOSꢀCircuit  
960VA/120W  
250VꢀAC/150VꢀDC  
5A  
Operation Type  
Multi-Mode  
Time Range  
1:ꢀ0.1secꢀtoꢀ6ꢀhours,ꢀ3:ꢀ0.1secꢀtoꢀ300ꢀhours  
2ꢀ(IE60664-1)  
Allowable Current  
Pollution Degree  
Over Voltage Category  
Maximum permissible  
operating frequency  
1800ꢀcyclesꢀperꢀhour  
IIIꢀ(IE60664-1)  
1/8HP,ꢀ240VꢀAC  
AF20  
AD24  
D12  
100-240VꢀAC(50/60Hz)  
24VꢀAC(50/60Hz)/24VꢀDC  
12VꢀDC  
3A,ꢀ240VꢀACꢀ(Resistive)  
Rated Operational Voltage  
Voltage Tolerance  
Rated Load  
5A,ꢀ120VꢀAC/30VꢀDCꢀ  
(Resistive)  
AF20  
AD24  
D12  
85-264VꢀAC(50/60Hz)  
20.4-26.4VꢀAC(50/60Hz)/21.6-26.4VꢀDC  
10.8-13.2VꢀDC  
Conditional Short Circuit  
Fuseꢀꢀꢀ5A,ꢀ250V  
100,000ꢀop.ꢀminimumꢀ  
(Resistive)  
Electrical  
Life  
Disengaging Value of Input Voltage  
RatedꢀVoltageꢀx10%ꢀminimum  
-10ꢀtoꢀ+50ºCꢀ(withoutꢀfreezing)  
Mechanical 20,000,000ꢀop.ꢀminimum  
Range of Ambient Operating Temperature  
Range of Ambient Storage  
and Transport Temperature  
-30ꢀtoꢀ+75ºCꢀ(withoutꢀfreezing)  
Range of Relative Humidity  
Atmospheric Pressure  
Reset Time  
35ꢀtoꢀ85%RHꢀ(withoutꢀcondensation)  
80kPaꢀtoꢀ110kPaꢀ(Operating),ꢀ70kPaꢀtoꢀ110kPaꢀ(Transport)ꢀ  
60msecꢀmaximum  
Repeat Error  
±0.2%,ꢀ±10msec*  
Voltage Error  
±0.2%,ꢀ±10msec*  
Temperature Error  
Setting Error  
±0.6%,ꢀ±10msec*  
±10%ꢀmaximum  
Insulation Resistance  
100MΩꢀminimumꢀ(500VꢀDC)  
Betweenꢀpowerꢀandꢀoutputꢀterminals:ꢀ2000VꢀAC,ꢀ1ꢀminute  
Betweenꢀcontactsꢀofꢀdifferentꢀpoles:ꢀ2000VꢀAC,ꢀ1ꢀminute  
Betweenꢀcontactsꢀofꢀtheꢀsameꢀpole:750VꢀAC,ꢀ1ꢀminute  
10ꢀtoꢀ55Hzꢀamplitudeꢀ0.75mm2ꢀhoursꢀinꢀeachꢀofꢀ3ꢀaxes  
Operatingꢀextremes:ꢀ98m/sec2ꢀ(approx.10G)ꢀ  
Damageꢀlimits:ꢀ490m/sec2ꢀ(approx.ꢀ50G)  
3ꢀtimesꢀinꢀeachꢀofꢀ3ꢀaxes  
Dielectric Strength  
Vibration Resistance  
Shock Resistance  
Degree of Protection  
IP40ꢀ(enclosure),ꢀIP20ꢀ(socket)ꢀꢀꢀꢀ(IEC60529)  
100VꢀAC/60Hz 2.3VA  
200VꢀAC/60Hz 4.6VA  
AF20  
Power Consumption  
(Approx.)  
AD24ꢀ(AC/DC)  
1.8VA/0.9W  
Mounting Position  
Dimensions  
Free  
40Hxꢀ36Wꢀxꢀ70ꢀmm  
72g  
Weight (Approx.)  
*ꢀForꢀtheꢀvalueꢀofꢀtheꢀerrorꢀagainstꢀaꢀpresetꢀtime,ꢀwhicheverꢀtheꢀlargestꢀapplies.  
www.IDEC.com  
856 ꢀ  
GT3W  
Timers  
Part Number List  
Time Range*  
Part Numbers  
Mode of Operation  
Output  
Contact  
Rated Voltage  
Pin Configuration  
New Part Numbers  
8ꢀpin  
GT3W-A11AF20N  
GT3W-A11EAF20N  
GT3W-A11AD24N  
GT3W-A11EAD24N  
GT3W-A11D12N  
GT3W-A11ED12N  
GT3W-A33AF20N  
GT3W-A33AD24N  
100ꢀtoꢀ240VꢀACꢀ  
(50/60Hz)  
11ꢀpin  
8ꢀpin  
A:ꢀSequentialꢀStart  
1:ꢀ0.1secꢀ-ꢀ6ꢀhours  
*(SeeꢀTimeꢀRangeꢀSet-  
tingsꢀforꢀdetails.)  
B:ꢀOn-delayꢀwithꢀcourseꢀandꢀfine  
C:ꢀRecyclerꢀandꢀinstaneous  
D:ꢀRecyclerꢀoutputsꢀ(OFFꢀStart)  
E:ꢀRecyclerꢀoutputsꢀ(ONꢀStart)  
F:ꢀIntervalꢀON  
G:ꢀIntervalꢀONꢀDelay  
H:ꢀSequentialꢀ  
24VꢀAC/DC  
12VꢀDC  
Delayed  
ꢀSPDT  
+
Delayed  
ꢀSPDT  
3A,ꢀ240VꢀAC  
11ꢀpin  
8ꢀpin  
5A,ꢀ120VꢀAC/30VꢀDC  
(ResistiveꢀLoad)  
11ꢀpin  
Interval  
100ꢀtoꢀ240VꢀACꢀ  
(50/60Hz)  
3:ꢀ0.1secꢀ-ꢀ300ꢀhours  
8ꢀpin  
24VꢀAC/DC  
1.ꢀ Forꢀtimingꢀdiagramsꢀandꢀschematics,ꢀseeꢀpageꢀ858.  
2.ꢀ Forꢀsocketꢀandꢀaccessoryꢀpartꢀnumberꢀinformation,ꢀseeꢀpageꢀ860.  
3.ꢀ 8-ꢀandꢀ11-pinꢀmodelsꢀdifferꢀonlyꢀinꢀtheꢀnumberꢀofꢀpinsꢀ(extraꢀpinsꢀareꢀnotꢀused).  
4.ꢀ Forꢀtheꢀtimingꢀdiagramꢀoverview,ꢀseeꢀpageꢀ832.  
5.ꢀ*Forꢀdetailsꢀonꢀsettingꢀtimeꢀranges,ꢀseeꢀtheꢀinstructionsꢀonꢀpageꢀ859.  
Time Range Table  
Time Range Code: 1  
Scale  
Time Range Code: 3  
Time Range  
Selector  
Time Range  
Selector  
Time Range  
Scale  
Time Range  
1S  
10S  
10M  
1S  
0.1ꢀsecꢀ-ꢀ1ꢀsec  
0.3ꢀsecꢀ-ꢀ10ꢀsec  
15ꢀsecꢀ-ꢀ10ꢀmin  
0.1ꢀsecꢀ-ꢀ6ꢀsec  
1ꢀsecꢀ-ꢀ60ꢀsec  
6ꢀsecꢀ-ꢀ6ꢀmin  
1S  
1M  
1H  
1S  
0.1ꢀsecꢀ-ꢀ3ꢀsec  
3ꢀsecꢀ-ꢀ3ꢀmin  
0-1  
0ꢀ-ꢀ3  
3ꢀminꢀ-ꢀ3ꢀhours  
0.6ꢀsecꢀ-ꢀ30ꢀsec  
36ꢀsecꢀ-ꢀ30ꢀmin  
36minꢀ-ꢀ30ꢀhours  
10S  
1M  
10M  
1H  
1M  
1H  
0ꢀ-ꢀ6  
0ꢀ-ꢀ30  
1ꢀminꢀ-ꢀ60ꢀmin  
6ꢀminꢀ-ꢀ6ꢀhours  
10H  
6ꢀhoursꢀ-ꢀ300ꢀhours  
800-262-IDEC (4332) USA & Canada  
857  
GT3W  
Timers  
Timing Diagrams/Schematics  
Mode  
OperationꢀChart  
Mode  
OperationꢀChart  
Terminal  
No.  
Terminal  
No.  
Item  
Operation  
Description  
Item  
Operation  
Description  
Power  
2-7  
Power  
2-7  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
Delayed  
Contact  
Ry1  
Delayed  
Contact  
Ry1  
ON during T1  
OFF during T2  
ON after T1  
Delayed  
Contact  
Ry2  
Delayed  
Contact  
Ry2  
ON during T1  
OFF during T2  
ON after T1 + T2  
OUT1  
OUT2  
OUT1  
OUT2  
Indicator  
Indicator  
Set Time  
Set Time  
T1  
T2  
T1  
T2  
Terminal  
No.  
Terminal  
No.  
Item  
Operation  
Description  
Item  
Operation  
Description  
Power  
2-7  
Power  
2-7  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
Delayed  
Contact  
Ry1  
Delayed  
Contact  
Ry1  
ON during T1  
ON after T1 + T2  
ON after T1 + T2  
Delayed  
Contact  
Ry2  
Delayed  
Contact  
Ry2  
ON after T1,  
during T2  
OUT1  
OUT2  
OUT1  
OUT2  
Indicator  
Indicator  
Set Time  
Set Time  
T1  
T2  
T1  
T2  
Terminal  
No.  
Terminal  
No.  
Item  
Operation  
Description  
Item  
Operation  
Description  
Power  
2-7  
Power  
2-7  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
Delayed  
Contact  
Ry1  
Delayed  
Contact  
Ry1  
Instantaneous ON  
ON during T1  
Delayed  
Contact  
Ry2  
Delayed  
Contact  
Ry2  
OFF during T1  
ON during T2  
ON after T1 + T2  
OUT1  
OUT2  
OUT1  
OUT2  
Indicator  
Indicator  
Set Time  
Set Time  
T1  
T2  
T1  
T2  
Terminal  
No.  
Terminal  
No.  
Item  
Operation  
Description  
Item  
Operation  
Description  
Power  
2-7  
Power  
2-7  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
1-4  
(NC)  
1-3  
(NO)  
5-8  
(NC)  
6-8  
(NO)  
Delayed  
Contact  
Ry1  
Delayed  
Contact  
Ry1  
OFF during T1  
ON during T2  
ON during T1 + T2  
Delayed  
Contact  
Ry2  
Delayed  
Contact  
Ry2  
OFF during T1  
ON during T2  
ON after T1,  
during T2  
OUT1  
OUT2  
OUT1  
OUT2  
Indicator  
Indicator  
Set Time  
Set Time  
T1  
T2  
T1  
T2  
www.IDEC.com  
858 ꢀ  
GT3W  
Timers  
Instructions: Setting GT3WTimer  
1.ꢀTheꢀswitchesꢀshouldꢀbeꢀsecurelyꢀturnedꢀusingꢀaꢀflatꢀscrewdriverꢀ4mmꢀ  
wideꢀ(maximum).ꢀNoteꢀthatꢀincorrectꢀsettingꢀmayꢀcauseꢀmalfunction.ꢀ  
Theꢀswitches,ꢀwhichꢀdoꢀnotꢀturnꢀinfinitely,ꢀshouldꢀnotꢀbeꢀturnedꢀbeyondꢀ  
theirꢀlimits.  
T2ꢀSettingꢀKnob  
T1ꢀSettingꢀKnob  
T2ꢀTimeꢀRangeꢀSelector  
OperationꢀModeꢀSelector  
T1ꢀTimeꢀRangeꢀSelector  
2.ꢀSinceꢀchangingꢀtheꢀsettingꢀduringꢀtimerꢀoperationꢀmyꢀcauseꢀmalfunction,ꢀ  
turnꢀpowerꢀoffꢀbeforeꢀchanging.  
Safety Precautions  
SpecialꢀexpertiseꢀisꢀrequiredꢀtoꢀuseꢀElectronicꢀTimers.  
Caution  
•ꢀ AllꢀElectronicꢀTimerꢀmodulesꢀareꢀmanufacturedꢀunderꢀIDEC’sꢀrigorousꢀqualityꢀ  
controlꢀsystem,ꢀbutꢀusersꢀmustꢀaddꢀaꢀbackupꢀorꢀfailꢀsafeꢀprovisionꢀtoꢀtheꢀ  
controlꢀsystemꢀwhenꢀusingꢀtheꢀElectronicꢀTimerꢀinꢀapplicationsꢀwhereꢀheavyꢀ  
damageꢀorꢀpersonalꢀinjuryꢀmayꢀoccurꢀshouldꢀtheꢀElectronicꢀTimerꢀfail.  
Cautionꢀnoticesꢀareꢀusedꢀwhereꢀinattentionꢀmightꢀcauseꢀpersonalꢀinjuryꢀorꢀdam-  
ageꢀtoꢀequipment.  
•ꢀ TheꢀElectronicꢀTimerꢀisꢀdesignedꢀforꢀinstallationꢀinꢀequipment.ꢀDoꢀnotꢀinstallꢀ  
theꢀElectronicꢀTimerꢀoutsideꢀequipment.  
•ꢀ InstallꢀtheꢀElectronicꢀTimerꢀaccordingꢀtoꢀinstructionsꢀdescribedꢀinꢀthisꢀcatalog.  
•ꢀ InstallꢀtheꢀElectronicꢀTimerꢀinꢀenvironmentsꢀdescribedꢀinꢀtheꢀspecifications.ꢀIfꢀ  
theꢀElectronicꢀTimerꢀisꢀusedꢀinꢀplacesꢀwhereꢀitꢀwillꢀbeꢀsubjectedꢀtoꢀhigh-tem-  
perature,ꢀhigh-humidity,ꢀcondensation,ꢀcorrosiveꢀgases,ꢀexcessiveꢀvibrations,ꢀ  
orꢀexcessiveꢀshocks,ꢀthenꢀelectricalꢀshocks,ꢀfireꢀhazard,ꢀorꢀmalfunctionꢀcouldꢀ  
result.  
•ꢀ Makeꢀsureꢀthatꢀtheꢀoperatingꢀconditionsꢀareꢀasꢀdescribedꢀinꢀtheꢀspecifica-  
tions.ꢀIfꢀyouꢀareꢀuncertainꢀaboutꢀtheꢀspecifications,ꢀcontactꢀIDECꢀinꢀadvance.  
•ꢀ Inꢀtheseꢀdirections,ꢀsafetyꢀprecautionsꢀareꢀcategorizedꢀinꢀorderꢀofꢀimportanceꢀ  
toꢀWarningꢀandꢀCaution.  
•ꢀ UseꢀanꢀIEC60127-approvedꢀfuseꢀandꢀcircuitꢀbreakerꢀonꢀtheꢀpowerꢀandꢀoutputꢀ  
lineꢀoutsideꢀtheꢀElectronicꢀTimer.  
Warning  
•ꢀ Doꢀnotꢀdisassemble,ꢀrepair,ꢀorꢀmodifyꢀtheꢀElectronicꢀTimer.  
Warningꢀnoticesꢀareꢀusedꢀtoꢀemphasizeꢀthatꢀimproperꢀoperationꢀmayꢀcauseꢀseverꢀ  
personalꢀinjuryꢀorꢀdeath.  
•ꢀ WhenꢀdisposingꢀofꢀtheꢀElectronicꢀTimer,ꢀdoꢀsoꢀasꢀindustrialꢀwaste.  
•ꢀ TurnꢀpowerꢀoffꢀtoꢀtheꢀElectronicꢀtimerꢀbeforeꢀstartingꢀinstallation,ꢀremoval,ꢀ  
Wiring,ꢀmaintenance,ꢀandꢀinspectionꢀonꢀtheꢀElectronicꢀTimer.ꢀ  
•ꢀ Failureꢀtoꢀturnꢀpowerꢀoffꢀmayꢀcauseꢀelectricalꢀshocksꢀorꢀfireꢀhazard.  
•ꢀ Emergencyꢀstopꢀandꢀinterlockingꢀcircuitsꢀmustꢀbeꢀconfiguredꢀoutsideꢀtheꢀ  
Electronicꢀtimer.ꢀIfꢀsuchꢀaꢀcircuitꢀisꢀconfiguredꢀinsideꢀtheꢀElectronicꢀTimer,ꢀ  
failureꢀofꢀtheꢀElectronicꢀtimerꢀmayꢀcauseꢀmalfunctionꢀofꢀtheꢀcontrolꢀsystem,ꢀorꢀ  
anꢀaccident.  
800-262-IDEC (4332) USA & Canada  
859  
GT3 Series Accessories  
Timers  
GT3 Series  
Accessories  
DIN Rail Mounting Accessories  
DIN Rail/Surface Mount Sockets and Hold-Down Springs  
DIN Rail Mount Socket  
Applicable Hold-Down Springs  
Appearance Part No.  
Style  
Appearance  
Use with Timers  
Part No.  
GT3A-1, 2, 3 (8-pin)  
GT3F-1, 2 (8-pin)  
GT3W (8-pin)  
8-Pin Screw Terminal  
(dual tier)  
SR2P-05  
GT3A-1, 2, 3 (11-pin)  
GT3A-4, 5, 6  
GT3F-1, 2 (11-pin)  
GT3W (11-pin)  
11-Pin Screw Terminal  
(dual tier)  
SR3P-05  
SFA-203  
GT3A-1, 2, 3 (8-pin)  
GT3F-1, 2 (8-pin)  
GT3W (8-pin)  
8-Pin Fingersafe Socket  
11-Pin Fingersafe Socket  
8-Pin Screw Terminal  
11-Pin Screw Terminal  
SR2P-05C  
SR3P-05C  
SR2P-06  
SR3P-06  
GT3A-1, 2, 3 (11-pin)  
GT3A-4, 5, 6  
GT3F-1, 2 (11-pin)  
GT3W (11-pin)  
GT3A-1, 2, 3 (8-pin)  
GT3F-1, 2 (8-pin)  
GT3W (8-pin)  
SFA-202  
GT3A-1, 2, 3 (11-pin)  
GT3A-4, 5, 6  
GT3F-1, 2 (11-pin)  
GT3W (11-pin)  
DIN Mounting Rail  
Length 1000mm  
BNDN1000  
Installation of Hold-Down Springs  
DIN Rail Mount Socket  
Insert the springs into the outer  
slots with the projections  
facing inside.  
Panel Mount Socket  
Hold-down Spring  
SFA-402  
Insert the springs  
into the slots.  
Insert  
8-pin Socket  
SR2P-51  
Socket SR2P-05  
Hold-down Spring (sold separately)  
SFA-203 (use two springs)  
Socket SR2P-06  
Hold-down Spring (sold separately)  
SFA-202 (use two springs)  
www.IDEC.com  
860  
GT3 Series Accessories  
Timers  
Panel Mounting Accessories  
Panel Mount Sockets and Hold-Down Springs  
Panel Mount Socket  
Applicable HD Springs  
Style  
Appearance  
Use with Timers  
Part No.  
Appearance  
Part No.  
GT3A- (8-pin)  
GT3W- (8-pin)  
GT3F- (8-pin)  
8-Pin Solder Terminal  
SR2P-51  
SFA-402  
GT3A- (11-pin)  
GT3W- (11-pin)  
GT3F- (11-pin)  
11-Pin Solder Terminal  
SR3P-51  
For information on installing the hold-down springs, see page 860.  
Flush Panel Mount Adapter and Sockets that use an Adapter  
Accessory  
Description  
Appearance  
Use with Timers  
Part No.  
Panel Mount Adapter Adaptor for flush panel mounting GT3 timers  
All GT3 timers  
RTB-G01  
8-pin screw terminal  
All 8-pin timers  
SR6P-M08G  
SR6P-M11G  
(Shown: SR6P-M08G for Wiring Socket Adapter)  
11-pin screw terminal  
All 11-pin timers  
Sockets for use with  
Panel Mount Adapter  
8-pin solder terminal  
All 8-pin timers  
All 11-pin timers  
SR6P-S08  
SR6P-S11  
11-pin solder terminal  
No hold down springs are available for flush panel mounting.  
800-262-IDEC (4332) USA & Canada  
861  
GT3 Series Instructions  
Timers  
Instructions:Wiring Inputs for GT3 Series  
Inputs  
To avoid electric shock, do not touch the input signal terminal during power voltage application.  
When connecting the input signal terminals of two or more GT3A timers to the same contact or transistor, the input terminals of the same number should be con-  
nected. (Connect Terminals No.2 in common.)  
[Incorrect]  
Input  
Contact or Transistor  
GT3 Series  
Timer  
[correct]  
Input  
Input  
Terminal  
Terminal  
2
2
10  
10  
2
10  
Power  
Power  
Input  
Terminal  
Input  
Terminal  
2
10  
In a transistor circuit for controlling input signals, with its primary and secondary power circuits isolated, do not ground the secondary circuit.  
GT3 Series  
Timer  
Input  
Terminal  
Power  
Circuit  
Insulating Transformer  
Connect the input signal terminals of the GT3A timers to Terminal No.2 only. Never apply voltage to other terminals; otherwise, the internal circuit may be damaged.  
R
Y
5, 6, and 7  
Input Terminal  
2
10  
Power  
Input signal lines must be made as short as possible and installed away from power cables and power lines. Use shielded wires or a separate conduit for  
input wiring.  
www.IDEC.com  
862  
GT3 Series Instructions  
Timers  
Inputs Instructions, continued  
For contact input, use gold-plated contacts to make sure that the residual voltage is less than 1V when the contacts are closed.  
6
5
7
4
8
3
9
2
10  
1
11  
Power  
For transistor input, use transistors with the following specifications; VCE = 40V, VCES = 1V or less, IC = 50 mA or more, and ICBO = 50µA or less. The resistance  
should be less than 1kΩ when the transistor is on. When the output transistor switches on, a signal is input to the timer.  
6
5
7
4
8
3
9
2
10  
1
11  
Power  
Inputs: GT3A-1, -2, -3  
Transistor output equipment such as proximity switches and photoelectric switches can input signals if they are voltage/current output type, with power voltage  
ranges from 18 to 30V and have1V. When the signal voltage switches from H to L, a signal is input to the timer  
6
5
7
4
8
3
9
2
10  
1
11  
Power  
Inputs: GT3A-4, -5, -6  
The start input initiates a time-delay operation and controls  
output status.  
No-voltage contact inputs and NPN open collector transis-  
tor inputs are applicable.  
Start Input  
Reset Input  
Gate Input  
When the reset input is activated, the time is reset, and  
contacts return to original state.  
24V DC, 1mA maximum  
The time-delay operation is suspended while the gate input  
is on (pause).  
Input response time: 50msec maximum  
800-262-IDEC (4332) USA & Canada  
863  
GT3 Series Dimensions  
Timers  
Dimensions  
70.0  
36.0  
5.6  
Unit: mm  
NOTE: GT3W series are UL Listed when used in combination  
with following IDEC’s sockets:  
GT3W-A11, A33:  
GT3W-A11E:  
SR2P-06* pin type socket.  
SR3P-05* pin type socket.  
(*-May be followed by A,B,C or U)  
The socket to be used with these timers are rated:  
-Conductor Temperature Rating 60ºC min.  
-Use 14AWG max.(2mm2max.) Copper conductors only  
-Terminal Torque 1.0 to 1.3 N-m  
Analog GT3 Timer, 8-Pin with SR2P-06  
Analog GT3 Timer, 11-Pin with SR3P-06  
(When using  
When using BAA/BAP: 99 maximum  
DIN Rail)  
Analog Setting Type  
(When using  
When using BAA/BAP: 99 maximum  
DIN Rail)  
Analog Setting Type  
95 maximum  
95 maximum  
Hold-  
down  
spring  
Hold-  
down  
spring  
DIN Rail  
DIN Rail  
(
)
SFA-202  
(
)
SFA-202  
18  
22  
18  
22  
36  
8
64.2  
13  
36  
8
64.2  
13  
Analog GT3 Timer, 11-Pin with SR3P-05  
(When using DIN Rail)  
BAA or BAP: 105.5 maximum  
Analog Setting Type  
DIN Rail  
(BAA/BAP/BADA)  
101.5 maximum  
Hold-down  
Spring (SFA-203)  
16.5  
20  
36  
8
64.2  
13  
28.5  
Panel Mount Adapter  
Analog GT3 Timer, 8-Pin and 11-Pin  
with SR6P-S08 or SR6P-S11  
98 maximum  
Panel Thickness 0.8 to 5mm  
Back Wiring Socket  
48  
11  
61.2  
www.IDEC.com  
864  
GT3 Series Dimensions  
Timers  
Mounting Hole Layout  
Single  
Tolerance: +0.5 to 0  
N: No. of timers mounted  
Horizontal Close Mounting  
48N--3  
Mounting  
45  
GT3 Timer, 8-Pin with SR6P-M08G  
GT3 Timer, 11-Pin with SR6P-M11G  
8-M3.5 Terminal Screw  
44.6  
11-M3.5 Teminal Screws  
Panel Thickness 0.8 to 5mm  
45  
16.7  
1
3.5 max.  
6.9 max.  
5.6 min.  
5.8 min.  
3.5 max.  
6.9 max.  
ø3.6 min.  
3
2
4
1
5
8
6
7
2
11  
8
7
9
6
ø3.6 min.  
5
4
3
10  
7
30.5  
7
9.8 × 3  
80.5  
92  
8.5 × 4  
800-262-IDEC (4332) USA & Canada  
865  
General Instructions  
Timers  
General Instructions for AllTimer Series  
Load Current  
Vibration and Shock  
With inductive, capacitive, and incandescent lamp loads, inrush current more  
than 10 times the rated current may cause welded contacts and other undesired  
effects. The inrush current and steady-state current must be taken into consider-  
ation when specifying a timer.  
Excessive vibration or shocks can cause the output contacts to bounce, the  
timer should be used only within the operating extremes for vibration and shock  
resistance. In applications with significant vibration or shock, use of hold down  
springs or clips is recommended to secure a timer to its socket.  
Contact Protection  
Time Setting  
Switching an inductive load generates a counter-electromotive force (back EMF)  
in the coil. The back EMF will cause arcing, which may shorten the contact life  
and cause imperfect contact. Application of a protection circuit is recommended  
to safeguard the contacts.  
The time range is calibrated at its maximum time scale; so it is desirable to use  
the timer at a setting as close to its maximum time scale as possible. For a more  
accurate time delay, adjust the control knob by measuring the operating time  
with a watch before application.  
Temperature and Humidity  
Input Contacts  
Use the timer within the operating temperature and operating humidity ranges  
and prevent freezing or condensation. After the timer has been stored below  
its operating temperature, leave the timer at room temperature for a sufficient  
period of time to allow it to return to operating temperatures before use.  
Use mechanical contact switch or relay to supply power to the timer. When  
driving the timer with a solid-state output device (such as a two-wire proximity  
switch, photoelectric switch, or solid-state relay), malfunction may be caused by  
leakage current from the solid-state device. Since AC types comprise a capaci-  
tive load, the SSR dielectric strength should be two or more times the power  
voltage when switching the timer power using an SSR.  
Environment  
Generally, it is desirable to use mechanical contacts whenever possible to apply  
power to a timer or its signal inputs. When using solid state devices, be cautious  
of inrushes and back-EMF that may exceed the ratings on such devices. Some  
timers are specially designed so that signal inputs switch at a lower voltage  
than is used to power the timer (models designated as “B” type).  
Avoid contact between the timer and sulfurous or ammonia gases, organic sol-  
vents (alcohol, benzine, thinner, etc.), strong alkaline substances, or strong acids.  
Do not use the timer in an environment where such substances are prevalent. Do  
not allow water to run or splash on the timer.  
Timing Accuracy Formulas  
Timing accuracies are calculated from the following formulas:  
=
=
1 x Maximum Measured ꢀalue – Minimum Measured ꢀalue x 100%  
2 Maximum Scale ꢀalue  
Repeat Error  
Voltage Error  
Tv - Tr x 100%  
Tr  
Tv: Average of measured values at voltage ꢀ  
Tr: Average of measured values at the rated voltage  
=
Tt - T20 x 100%  
T20  
Temperature Error  
Tt: Average of measured values at °C  
T20: Average of measured values at 20°C  
=
Average of Measured ꢀalues - Set ꢀalue x 100%  
Maximum Scale ꢀalue  
Setting Error  
www.IDEC.com  
880  

相关型号:

GT3A-6

Analog Timers
ETC

GT3B-12/16DP-2.5DSA

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3B-16DP-2.5DSA

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3B-16DP-2.5DSA(70)

PCB Connector, 16 Contact(s), 2 Row(s), Male, Straight, 0.098 inch Pitch, Solder Terminal, Locking, Black Insulator
HRS

GT3B-20DP-2.5DSA

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3B-20DP-2.5DSA(70)

PCB Connector, 20 Contact(s), 2 Row(s), Male, Straight, 0.098 inch Pitch, Solder Terminal, Locking, Black Insulator
HRS

GT3TK-36DP-DSA

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3TK-48TP-DS

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3TK-8DP-DS

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3TK-8DP-DSA

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3TKW-12DP-DS

Antenna, Sensor, and Communications Trunk Line Connections
HRS

GT3TKW-12DP-DSA

Antenna, Sensor, and Communications Trunk Line Connections
HRS