GX-18MU [ETC]
Cylindrical Inductive Proximity Sensor Amplifier Built-in; 圆柱形接近传感器放大器内置型号: | GX-18MU |
厂家: | ETC |
描述: | Cylindrical Inductive Proximity Sensor Amplifier Built-in |
文件: | 总16页 (文件大小:803K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Amplifier Built-in
Cylindrical Inductive Proximity Sensor
795
GX-U SERIES GX-FU SERIES GX-N SERIES
■General terms and conditions........... F-17
■Glossary of terms........................ P.1386~
■Sensor selection guide.................. P.757~
■General precautions ..................... P.1405
FIBER
SENSORS
Related Information
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic-electric-works.net/sunx
2-wire type
available
Oil resistant Metal embedding
possible
STATIC CONTROL
DEVICES
Improved performance, environmental resistance,
and operability
ENDOSCOPE
LASER
MARKERS
PLC /
TERMINALS
BASIC PERFORMANCE
HUMAN MACHINE
INTERFACES
About four times more robust in tightening
Long sensing range
ENERGY CONSUMPTION
VISUALIZATION
As the sensor can be securely tightened, it does not get
loose due to vibration or shock.
GX-12MLU(B)/N12ML(B) feature 1.6 times longer
sensing range than previous model [GX-12ML(B)]. It can
be mounted at a sufficient distance from the object.
COMPONENTS
FA COMPONENTS
GX-18MU(B)
GX-N18M(B)
GX-18M(B)
Conventional model
MACHINE VISION
SYSTEMS
GX-12MLU(B)
GX-N12ML(B)
4 times approx. 80 N·m or less
19.6 N·m or less
UV CURING
SYSTEMS
8 mm
0.315 in
ENVIRONMENTAL RESISTANCE
Spatter-resistant type available
FUNCTIONS
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
DC 2-wire type
Visible 2-color indicator
As the enclosure is entirely
coated by fluorine resin, the
sensor can be safely used
at a place where welding
spatters fly around.
Both the pigtail cable and
the mating cable are also
spatter-resistant.
The normally open type [GX-(F)□U(-J)] is equipped with
a 2-color indicator. (The normally closed type and GX-N□
have the operation indicator
instead.)
The operation is easily
observable from any direction
because the entire sensor
tail (transparent, GX-5SU(B):
enclosure) lights up.
GX-F/H
GXL
GL
GX-F□U-J
GX-U/GX-FU/
GX-N
GX
VARIETIES
DC 2-wire type
Simple wiring
Compact size: ø5.4 mm ø0.213 in
GX-5SU(B) is just 5.4
mm 0.213 in in diameter,
the smallest in existing
DC two-wire sensors. It
saves you space.
The wiring cost is considerably reduced as it is DC 2-
wire type.
Further, each of GX-12M(L)U(B),
GX-18M(L)U(B),
ø5.4 mm
ø0.213 in
GX-30M(L)U(B)
is available as a pigtailed
model that makes
replacement easy
and quick.
Pigtailed type
GX-□U(B)-J
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
796
APPLICATIONS
FIBER
SENSORS
LASER
Detecting traveling aluminum pallets
Controlling depth of drilling
Positioning object at welding station
SENSORS
(GX-F□U-J only)
It can be safely used even where welding
sparks (spatter) fly around.
It can reliably detect even aluminum
pallets because of its long
sensing range.
By detecting the dog, the sensor decides
the depth of the
drilled hole.
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
ORDER GUIDE
SENSOR
OPTIONS
DC 2-wire type
SIMPLE
WIRE-SAVING
UNITS
Type
Appearance (mm in)
Sensing range (Note)
Model No.
Output
Output operation
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
ø5.4
1.5 mm 0.059 in
Maximum operation distance
GX-5SU
SENSORS
ø0.213
STATIC
30
CONTROL
DEVICES
1.181
(0 to 1.2 mm 0 to 0.047 in)
Stable sensing range
GX-5SUB
GX-8MU
ENDOSCOPE
2 mm 0.079 in
M8
LASER
MARKERS
30
1.181
(0 to 1.6 mm 0 to 0.063 in)
GX-8MUB
GX-12MU
GX-12MUB
GX-18MU
GX-18MUB
GX-30MU
GX-30MUB
GX-8MLU
GX-8MLUB
GX-12MLU
GX-12MLUB
GX-18MLU
GX-18MLUB
GX-30MLU
GX-30MLUB
PLC /
TERMINALS
HUMAN
3 mm 0.118 in
MACHINE
INTERFACES
M12
40.5
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
1.594
(0 to 2.4 mm 0 to 0.094 in)
FA
COMPONENTS
7 mm 0.276 in
MACHINE
VISION
M18
41.5
SYSTEMS
(0 to 5.6 mm 0 to 0.220 in)
1.634
UV
CURING
SYSTEMS
10 mm 0.394 in
Non-contact
DC 2-wire type
M30
44.5
1.752
(0 to 8 mm 0 to 0.315 in)
Selection
Guide
Amplifier
Built-in
4 mm 0.157 in
M8
Amplifier-
separated
30
1.181
(0 to 3.2 mm 0 to 0.126 in)
GX-F/H
GXL
GL
8 mm 0.315 in
M12
40.5
GX-U/GX-FU/
GX-N
1.594
(0 to 6.4 mm 0 to 0.252 in)
GX
15 mm 0.591 in
(0 to 12 mm 0 to 0.472 in)
M18
41.5
1.634
22 mm 0.866 in
(0 to 17.6 mm 0 to 0.693 in)
M30
44.5
1.752
Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
797
FIBER
ORDER GUIDE
SENSORS
LASER
Spatter-resistant of DC 2-wire type (Pigtailed type)
SENSORS
PHOTO-
ELECTRIC
SENSORS
Type
Appearance (mm in)
Sensing range (Note)
Model No.
Output
Output operation
MICRO
PHOTO-
ELECTRIC
SENSORS
Maximum operation distance
3 mm 0.118 in
AREA
GX-F12MU-J
SENSORS
M12
40.5
1.594
Stable sensing range
(0 to 2.4 mm 0 to 0.094 in)
LIGHT
CURTAINS
PRESSURE /
FLOW
7 mm 0.276 in
SENSORS
Non-contact
DC 2-wire type
Normally open
GX-F18MU-J
GX-F30MU-J
M18
41.5
INDUCTIVE
PROXIMITY
SENSORS
(0 to 5.6 mm 0 to 0.220 in)
1.634
PARTICULAR
USE
SENSORS
10 mm 0.394 in
SENSOR
OPTIONS
M30
44.5
(0 to 8 mm 0 to 0.315 in)
1.752
SIMPLE
WIRE-SAVING
UNITS
Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
• Mating cable
SENSORS
STATIC
CONTROL
DEVICES
ø14 mm ø0.551 in
Model No.
Description
300 mm
11.811 in
approx.
ENDOSCOPE
Mating cable
Length: 2 m 6.562 ft
Length: 5 m 16.404 ft
CN-22G-C2
CN-22G-C5
0.3 mm2 2-core flame-resistant, spatter-resistant cable
with connector at one end
Cable outer diameter: ø3.6 mm ø0.142 in
CN-22G-C2
(length 2 m 6.562 ft)
LASER
MARKERS
CN-22G-C5
(length 5 m 16.404 ft)
PLC /
TERMINALS
DC 3-wire type
HUMAN
MACHINE
INTERFACES
Type
Appearance (mm in)
Sensing range (Note)
Model No.
Output
Output operation
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
Normally open
Normally closed
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
GX-N12M
3 mm 0.118 in
Maximum operation distance
Stable sensing range
FA
COMPONENTS
M12
40.5
1.594
(0 to 2.4 mm 0 to 0.094 in)
MACHINE
VISION
GX-N12MB
GX-N18M
SYSTEMS
UV
CURING
7 mm 0.276 in
SYSTEMS
M18
41.5
1.634
(0 to 5.6 mm 0 to 0.220 in)
GX-N18MB
GX-N30M
Selection
Guide
10 mm 0.394 in
Amplifier
Built-in
M30
Amplifier-
separated
44.5
(0 to 8 mm 0 to 0.315 in)
GX-N30MB
GX-N12ML
GX-N12MLB
GX-N18ML
GX-N18MLB
GX-N30ML
GX-N30MLB
1.752
NPN
open-collector
transistor
GX-F/H
GXL
GL
8 mm 0.315 in
M12
40.5
1.594
(0 to 6.4 mm 0 to 0.252 in)
GX-U/GX-FU/
GX-N
GX
15 mm 0.591 in
M18
41.5
1.634
(0 to 12 mm 0 to 0.472 in)
22 mm 0.866 in
M30
44.5
(0 to 17.6 mm 0 to 0.693 in)
1.752
Note: The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
798
ORDER GUIDE
FIBER
SENSORS
LASER
5 m 16.404 ft cable length type
SENSORS
5 m 16.404 ft cable length type (standard: 2 m 6.562 ft) is also available for cable type.
When ordering this type, suffix “-C5” to the model No.
(e.g.) 5 m 16.404 ft cable length type of GX-5SU is “GX-5SU-C5”.
PHOTO-
ELECTRIC
SENSORS
MICRO
PHOTO-
ELECTRIC
SENSORS
Pigtailed type
AREA
SENSORS
Pigtailed type (standard: cable type) is also available for DC 2-wire type.
LIGHT
• Table of Model Nos.
CURTAINS
PRESSURE /
FLOW
Type
Standard
Pigtailed type (Note)
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
GX-5SU
PARTICULAR
USE
GX-5SUB
GX-8MU
SENSORS
SENSOR
OPTIONS
GX-8MUB
GX-12MU
GX-12MUB
GX-18MU
GX-18MUB
GX-30MU
GX-30MUB
GX-8MLU
GX-8MLUB
GX-12MLU
GX-12MLUB
GX-18MLU
GX-18MLUB
GX-30MLU
GX-30MLUB
SIMPLE
GX-12MU-J
GX-12MUB-J
GX-18MU-J
GX-18MUB-J
GX-30MU-J
GX-30MUB-J
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASURE-
MENT
SENSORS
STATIC
CONTROL
DEVICES
ENDOSCOPE
LASER
MARKERS
GX-12MLU-J
GX-12MLUB-J
GX-18MLU-J
GX-18MLUB-J
GX-30MLU-J
GX-30MLUB-J
PLC /
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
FA
Note: Please order the suitable mating cable separately for pigtailed type.
COMPONENTS
MACHINE
VISION
• Mating cable
SYSTEMS
UV
CURING
SYSTEMS
Model No.
Description
ø14 mm ø0.551 in
Length: 2 m 6.562 ft
0.3 mm2 2-core flame-resistant, spatter-resistant cable
with connector at one end
CN-22G-C2
CN-22G-C5
CN-24-C2
CN-24-C5
300 mm
11.811 in
approx.
Mating cable
Length: 5 m 16.404 ft Cable outer diameter: ø3.6 mm ø0.142 in
Selection
Guide
CN-22G-C□
CN-24-C□
Amplifier
Built-in
Length: 2 m 6.562 ft
0.3 mm2 4-core oil, heat, cold resistant cable
Cable outer diameter: ø3.6 mm ø0.142 in
Amplifier-
Length: 5 m 16.404 ft
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
799
FIBER
OPTIONS
SENSORS
LASER
SENSORS
Sensor mounting bracket
Designation
Model No.
Description
PHOTO-
ELECTRIC
SENSORS
• MS-SS5
MICRO
PHOTO-
Sensor mounting
bracket
The sensor is easily mounted with this
bracket.
For GX-5SU(B)
MS-SS5
MS-H12
MS-H18
MS-H30
ELECTRIC
SENSORS
For GX-12MU(B)
For GX-N12M(B)
AREA
SENSORS
Protection cover
LIGHT
• MS-H12
• MS-H18
• MS-H30
For GX-18MU(B)
For GX-N18M(B)
It protects the sensing surface from welding
sparks (spatter), etc.
CURTAINS
Protection cover
PRESSURE /
FLOW
SENSORS
For GX-30MU(B)
For GX-N30M(B)
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SPECIFICATIONS
SENSORS
SENSOR
OPTIONS
DC 2-wire type
SIMPLE
WIRE-SAVING
UNITS
Shielded type
Threaded type
Non-shielded type
Threaded type
Type
Non-threaded type
WIRE-SAVING
SYSTEMS
GX-5SU
GX-8MU GX-12MU GX-18MU GX-30MU GX-8MLU GX-12MLU GX-18MLU GX-30MLU
Normally open
Normally closed
MEASURE-
MENT
GX-5SUB GX-8MUB GX-12MUB GX-18MUB GX-30MUB GX-8MLUB GX-12MLUB GX-18MLUB GX-30MLUB
Item
SENSORS
Max. operation distance (Note 2)
Stable sensing range (Note 2)
1.5 mm 0.059 in ±10 % 2 mm 0.079 in ±10 % 3 mm 0.118 in ±10 % 7 mm 0.276 in ±10 % 10 mm 0.394 in ±10 % 4 mm 0.157 in ±10 % 8 mm 0.315 in ±10 % 15 mm 0.591 in ±10 % 22 mm 0.866 in ±10 %
0 to 1.2 mm 0 to 0.047 in 0 to 1.6 mm 0 to 0.063 in 0 to 2.4 mm 0 to 0.094 in 0 to 5.6 mm 0 to 0.220 in 0 to 8 mm 0 to 0.315 in 0 to 3.2 mm 0 to 0.126 in 0 to 6.4 mm 0 to 0.252 in 0 to 12 mm 0 to 0.472 in 0 to 17.6 mm 0 to 0.693 in
Iron sheet 6 × 6 × t 1 mm Iron sheet 8 × 8 × t 1 mm Iron sheet 12 × 12 × t 1 mm Iron sheet 18 × 18 × t 1mm Iron sheet 30 × 30 × t 1 mm Iron sheet 20 × 20 × t 1 mm Iron sheet 30 × 30 × t 1 mm Iron sheet 50 × 50 × t 1 mm Iron sheet 70 × 70 × t 1 mm
STATIC
CONTROL
DEVICES
ENDOSCOPE
Standard sensing object
0.236 × 0.236 × t 0.039 in 0.315 × 0.315 × t 0.039 in 0.472 × 0.472 × t 0.039 in 0.709 × 0.709 × t 0.0 39 in 1.181 × 1.181 × t 0.039 in 0.787 × 0.787 × t 0.039 in 1.181 ×1.181 × t 0.039 in
1.969 × 1.969 × t 0.039 in 2.756 × 2.756 × t 0.039 in
Hysteresis
20 % or less of operation distance (with standard sensing object)
LASER
MARKERS
+10
Supply voltage
12 to 24 V DC
% Ripple P-P 10 % or less
–15
PLC /
Current consumption (Note 3)
0.8 mA or less
TERMINALS
Non-contact DC 2-wire type
• Load current: 3 to 70 mA (Note 4)
• Residual voltage: 3 V or less (Note 5)
HUMAN
MACHINE
Output
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Incorporated
Short-circuit protection
Max. response frequency
Operation indicator
2-color indicator
1.7 kHz
1.2 kHz
1.2 kHz
500 Hz
350 Hz
1 kHz
650 Hz
350 Hz
220 Hz
FA
COMPONENTS
Normally closed type: Orange LED (lights up when the output is ON)
MACHINE
VISION
Normally open type: Lights up in green under stable sensing condition, lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM)
SYSTEMS
Protection
UV
CURING
Ambient temperature
Ambient humidity
–25 to +70 °C –13 to +158 °F, Storage: –30 to +80 °C –22 to +176 °F
SYSTEMS
45 to 85 % RH, Storage: 35 to 95 % RH
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range –25 to +70 °C –13 to +158 °F: within ±10 % of sensing range at +20 °C +68 °F
Within ±2 % for ±10 % fluctuation of the supply voltage
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
Sensing
range
Temperature characteristics
Voltage characteristics
variation
GX-F/H
GXL
GL
Enclosure: Brass (Nickel plated) [Stainless steel (SUS303) for GX-5SU(B), GX-8MU(B) and GX-8MLU(B)]
Sensing part: Nylon [Polyalylate for GX-5SU(B)], Indicator part: Nylon [excluding GX-5SU(B)]
Material
Cable
0.3 mm2 [0.15 mm2 for GX-5SU(B), GX-8MU(B) and GX-8MLU(B)] 2-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
Cable extension
Weight (Note 6)
Accessories
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
GX-U/GX-FU/
GX-N
Net weight: Net weight: Net weight: Net weight: Net weight:
Net weight: Net weight: Net weight: Net weight:
GX
20 g approx. 30 g approx. 55 g approx. 95 g approx. 220 g approx. 30 g approx. 55 g approx. 95 g approx. 220 g approx.
Nut: 2 pcs., Toothed lock washer: 1 pc.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
3) It is the leakage current when the output is in the OFF state.
4) The maximum load current varies depending on the ambient temperature. Refer to “I/O CIRCUIT AND WIRING DIAGRAMS” for more details.
5) When the cable is extended, the residual voltage becomes larger.
6) The weight of the threaded type includes the weight of two nuts and one toothed lock washer.
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
800
SPECIFICATIONS
FIBER
SENSORS
LASER
Spatter-resistant of DC 2-wire type (Pigtailed type)
SENSORS
PHOTO-
Shielded type
Threaded type
ELECTRIC
SENSORS
Type
MICRO
PHOTO-
ELECTRIC
SENSORS
Model No.
GX-F12MU-J
3 mm 0.118 in ±10 %
0 to 2.4 mm 0 to 0.094 in
GX-F18MU-J
GX-F30MU-J
Item
Max. operation distance (Note 2)
Stable sensing range (Note 2)
Standard sensing object
Hysteresis
7 mm 0.276 in ±10 %
0 to 5.6 mm 0 to 0.220 in
10 mm 0.394 in ±10 %
0 to 8 mm 0 to 0.315 in
AREA
SENSORS
LIGHT
CURTAINS
Iron sheet 12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in Iron sheet 18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in Iron sheet 30 × 30 × t 1 mm 1.181 ×1.181 × t 0.039 in
PRESSURE /
FLOW
20 % or less of operation distance (with standard sensing object)
SENSORS
+10
Supply voltage
12 to 24 V DC
% Ripple P-P 10 % or less
–15
INDUCTIVE
PROXIMITY
SENSORS
Current consumption (Note 3)
0.8 mA or less
PARTICULAR
USE
Non-contact DC 2-wire type
• Load current: 3 to 70 mA (Note 4)
• Residual voltage: 3 V or less (Note 5)
SENSORS
Output
SENSOR
OPTIONS
Output operation
Short-circuit protection
Max. response frequency
2-color indicator
Normally open
Incorporated
500 Hz
SIMPLE
WIRE-SAVING
UNITS
1.2 kHz
350 Hz
WIRE-SAVING
SYSTEMS
Lights up in green under stable sensing condition, lights up in orange under unstable sensing condition
IP67 (IEC), IP67g (JEM)
MEASURE-
MENT
Protection
SENSORS
Ambient temperature
Ambient humidity
–25 to +70 °C –13 to +158 °F, Storage: –30 to +80 °C –22 to +176 °F
STATIC
CONTROL
DEVICES
45 to 85 % RH, Storage: 35 to 95 % RH
ENDOSCOPE
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
1,000 V AC for one min. between all supply terminals connected together and enclosure
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range –25 to +70 °C –13 to +158 °F: within ±10 % of sensing range at +20 °C +68 °F
Within ±2 % for ±10 % fluctuation of the supply voltage
LASER
MARKERS
PLC /
TERMINALS
Sensing
range
variation
Temperature characteristics
Voltage characteristics
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Material
Cable
Enclosure: Brass (Fluorine resin coated), Sensing part: Polyalylate (Fluorine resin coated), Indicator part: Polyalylate
0.3 mm2 2-core spatter-resistant cable, 0.3 m 0.984 ft long with round type connector
Extension up to total 50 m 164.042 ft is possible with 0.3 mm2, or more, cable.
FA
COMPONENTS
Cable extension
Weight (Note 6)
Accessories
MACHINE
VISION
Net weight: 35 g approx.
Net weight: 75 g approx.
Net weight: 200 g approx.
SYSTEMS
Nut: 2 pcs. (Fluorine resin coated), Toothed lock washer: 1 pc. (Fluorine resin coated)
UV
CURING
SYSTEMS
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
3) It is the leakage current when the output is in the OFF state.
4) The maximum load current varies depending on the ambient temperature. Refer to “I/O CIRCUIT AND WIRING DIAGRAMS” for more details.
5) When the cable is extended, the residual voltage becomes larger.
Selection
Guide
Amplifier
Built-in
6) The given weight includes the weight of two nuts and one toothed lock washer.
Amplifier-
separated
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
801
FIBER
SPECIFICATIONS
SENSORS
LASER
DC 3-wire type
SENSORS
PHOTO-
ELECTRIC
SENSORS
Shielded type
Threaded type
Non-shielded type
Threaded type
Type
MICRO
PHOTO-
ELECTRIC
SENSORS
Item
Model No. GX-N12M GX-N12MB GX-N18M GX-N18MB GX-N30M GX-N30MB GX-N12ML GX-N12MLB GX-N18ML GX-N18MLB GX-N30ML GX-N30MLB
Max. operation distance (Note 2) 3 mm 0.118 in ±10 % 7 mm 0.276 in ±10 % 10 mm 0.394 in ±10 % 8 mm 0.315 in ±10 % 15 mm 0.591 in ±10 % 22 mm 0.866 in ±10 %
AREA
SENSORS
Stable sensing range (Note 2)
0 to 2.4 mm 0 to 0.094 in 0 to 5.6 mm 0 to 0.220 in 0 to 8 mm 0 to 0.315 in 0 to 6.4 mm 0 to 0.252 in 0 to 12 mm 0 to 0.472 in 0 to 17.6 mm 0 to 0.693 in
LIGHT
CURTAINS
Iron sheet 12 × 12 × t 1 mm Iron sheet 18 × 18 × t 1 mm Iron sheet 30 × 30 × t 1 mm Iron sheet 30 × 30 × t 1 mm Iron sheet 50 × 50 × t 1 mm Iron sheet 70 × 70 × t 1 mm
0.472 × 0.472 × t 0.039 in 0.709 × 0.709 × t 0.039 in 1.181 ×1.181 × t 0.039 in 1.181 ×1.181 × t 0.039 in 1.969 × 1.969 × t 0.039 in 2.756 × 2.756 × t 0.039 in
Standard sensing object
PRESSURE /
FLOW
Hysteresis
20 % or less of operation distance (with standard sensing object)
SENSORS
+10
INDUCTIVE
PROXIMITY
SENSORS
Supply voltage
Current consumption
12 to 24 V DC
% Ripple P-P 10 % or less
–15
10 mA or less
PARTICULAR
USE
SENSORS
NPN open-collector transistor
• Maximum sink current: 100 mA
SENSOR
OPTIONS
Output
• Applied voltage: 30 V DC or less (between output and 0 V)
• Residual voltage: 1.5 V or less (at 100 mA sink current)
0.4 V or less (at 16 mA sink current)
SIMPLE
WIRE-SAVING
UNITS
Output operation
Short-circuit protection
Max. response frequency
Operation indicator
Protection
Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed Normally open Normally closed
WIRE-SAVING
SYSTEMS
Incorporated
MEASURE-
MENT
450 Hz
300 Hz
300 Hz
350 Hz
100 Hz
100 Hz
SENSORS
Orange LED (lights up when the output is ON)
IP67 (IEC), IP67g (JEM)
STATIC
CONTROL
DEVICES
Ambient temperature
Ambient humidity
–25 to +70 °C –13 to +158 °F, Storage: –30 to +80 °C –22 to +176 °F
45 to 85 % RH, Storage: 35 to 95 % RH
ENDOSCOPE
LASER
MARKERS
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
1,000 V AC for one min. between all supply terminals connected together and enclosure
PLC /
50 MΩ, or more, with 250 V DC megger between all supply terminals connected together and enclosure
10 to 55 Hz frequency, 1.5 mm 0.059 in amplitude in X, Y and Z directions for two hours each
1,000 m/s2 acceleration (100 G approx.) in X, Y and Z directions for three times each
Over ambient temperature range –25 to +70 °C –13 to +158 °F: within ±10 % of sensing range at +20 °C +68 °F
Within ±2 % for ±10 % fluctuation of the supply voltage
TERMINALS
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Sensing
range
variation
Temperature characteristics
Voltage characteristics
FA
COMPONENTS
Material
Cable
Enclosure: Brass (Nickel plated), Sensing part: Nylon, Indicator part: Nylon
MACHINE
VISION
0.3 mm2 3-core oil, heat and cold resistant cabtyre cable, 2 m 6.562 ft long
SYSTEMS
Cable extension
Weight (Note 3)
Accessories
Extension up to total 100 m 328.084 ft is possible with 0.3 mm2, or more, cable.
UV
CURING
SYSTEMS
Net weight:
65 g approx.
Net weight:
Net weight:
Net weight:
Net weight:
Net weight:
240 g approx.
110 g approx.
240 g approx.
65 g approx.
110 g approx.
Nut: 2 pcs., Toothed lock washer: 1 pc.
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
2) The maximum operation distance stands for the maximum distance for which the sensor can detect the standard sensing object.
The stable sensing range stands for the sensing range for which the sensor can stably detect the standard sensing object even if there is an ambient
temperature drift and/or supply voltage fluctuation.
Selection
Guide
Amplifier
Built-in
Amplifier-
separated
3) The given weight includes the weight of two nuts and one toothed lock washer.
GX-F/H
GXL
GL
GX-U/GX-FU/
GX-N
GX
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
802
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
DC 2-wire type
GX-□U(B)
I/O circuit diagram
PHOTO-
Wiring diagram
ELECTRIC
SENSORS
Color code Bleeder resistance
MICRO
Color code
PHOTO-
ELECTRIC
SENSORS
(Brown) Output
Bleeder resistance
Load
Load
Brown
Blue
3 to 70 mA in ON state (Note)
0.8 mA in OFF state
AREA
Tr
SENSORS
ZD
+
12 to 24 V DC
+10
%
3 V in ON state
+
–
–
12 to 24 V DC
–15
LIGHT
+10
%
CURTAINS
–15
PRESSURE /
FLOW
Load
Load
(Blue) 0 V
Users’ circuit
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Internal circuit
Conditions for the load
Note: The maximum load current varies depending on the ambient temperature.
1) The load should not be actuated by the leakage current (0.8 mA) in
the OFF state.
2) The load should be actuated by (supply voltage – 3 V) in the ON state.
3) The current in the ON state should be between 3 to 70 mA DC.
PARTICULAR
USE
70
SENSORS
SENSOR
OPTIONS
In case the current is less than 3 mA, connect a bleeder resistance
in parallel to the load so that a current of 3 mA, or more, flows.
35
3
SIMPLE
WIRE-SAVING
UNITS
–25
–13
+55
+70
WIRE-SAVING
SYSTEMS
+131
+158
Ambient temperature (°C °F)
MEASURE-
MENT
Symbols ... ZD: Surge absorption zener diode
Tr : PNP output transistor
SENSORS
STATIC
CONTROL
DEVICES
Spatter-resistant of DC 2-wire type
GX-□U(B)-J GX-F□U-J
ENDOSCOPE
I/O circuit diagram
Wiring diagram
LASER
MARKERS
Color code of mating cable / Connector pin No.
Bleeder resistance
Color code of mating cable / Connector pin No.
Bleeder resistance
PLC /
TERMINALS
(Brown / 1)
Output
Brown / 1
Load
HUMAN
Load
MACHINE
INTERFACES
+
–
12 to 24 V DC
3 to 70 mA in ON state (Note 2)
+10
%
ENERGY
Tr
Z
D
0.8 mA in OFF state
+
–15
12 to 24 V DC
CONSUMPTION
VISUALIZATION
COMPONENTS
Blue / 2,4
(Note)
+10
%
3 V in ON state
–
–15
Load
FA
COMPONENTS
Note: This is when the mating cable CN-22G-C□ is connected. The connecter
pins No.2 and No.4 are short-circuited inside the mating cable connecter.
However, when the mating cable CN-24-C□ is connected;
GX-□U-J (normally open): Black / 4
Load
(Blue / 2,4) 0 V
(Note 1)
MACHINE
VISION
SYSTEMS
Internal circuit
Users’ circuit
UV
GX-□UB-J (normally closed): White / 2
Notes: 1) This is when the mating cable CN-22G-C□ is connected. The connecter
pins No.2 and No.4 are short-circuited inside the mating cable
connecter. However, when the mating cable CN-24-C□ is connected;
GX-□U-J (normally open): (Black / 4) 0 V
CURING
SYSTEMS
Connector pin position
Color code of
GX-□UB-J (normally closed): (White / 2) 0 V
2) The maximum load current varies depending on the ambient
temperature.
GX-□U-J (Normally open)
mating cable /
Mating cable
Connector pin No.
Selection
Guide
CN-22G-C□
(Brown / 1) Output
(Blue / 2,4) 0 V (Note)
Amplifier
1
+V
Built-in
Not co2nnected
70
35
3
Amplifier-
Color code of
separated
mating cable /
Connector pin No.
Mating cable
CN-24-C□
4
0 V
(Brown / 1) Output
3
GX-F/H
GXL
GL
White
Not connected
Not connected
Blue
(Black / 4) 0 V
Color code of
–25
–13
+55
+70
GX-□UB-J (Normally closed)
mating cable /
Connector pin No.
+131
+158
Mating cable
Ambient temperature (°C °F)
GX-U/GX-FU/
GX-N
CN-22G-C□
(Brown / 1) Output
(Blue / 2,4) 0 V (Note)
1
Conditions for the load
1) The load should not be actuated by the leakage current (0.8 mA) in
the OFF state.
2) The load should be actuated by (supply voltage – 3 V) in the ON state.
3) The current in the ON state should be between 3 to 70 mA DC.
GX
+V
2
0 V
Color code of
mating cable /
Connector pin No.
Mating cable
CN-24-C□
Not co4nnected
(Brown / 1) Output
3
Black
In case the current is less than 3 mA, connect a bleeder resistance
in parallel to the load so that a current of 3 mA, or more, flows.
Not connected
Not connected
Blue
(White / 2) 0 V
Color code of
mating cable /
Connector pin No.
GX-F□U-J (Spatter-resistant type)
Mating cable
CN-22G-C□
Symbols ... ZD: Surge absorption zener diode
Tr : PNP output transistor
1
+V
(Brown / 1) Output
Not co2nnected
(Blue / 2,4) 0 V (Note)
Note: The connecter pins No.2 and No.4 are short-
circuited inside the mating cable connector.
0 V
4
3
Not connected
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
803
FIBER
I/O CIRCUIT AND WIRING DIAGRAMS
SENSORS
LASER
SENSORS
DC 3-wire type (NPN output)
GX-N□
I/O circuit diagram
PHOTO-
ELECTRIC
SENSORS
Wiring diagram
Color code
Color code
MICRO
PHOTO-
(Brown) +V
Brown
ELECTRIC
SENSORS
D
Load
Load
AREA
+
–
12 to 24 V DC
12 to 24 V DC
+
–
Black
Blue
(Black) Output (Note)
SENSORS
+10
%
+10
%
Tr
–15
–15
100 mA max.
(Blue) 0 V
LIGHT
ZD
CURTAINS
PRESSURE /
FLOW
SENSORS
Internal circuit
Users’ circuit
INDUCTIVE
PROXIMITY
SENSORS
Note: If a capacitive load is directly connected to the output, malfunction may occur.
Symbols ... D : Reverse supply polarity protection diode
ZD: Surge absorption zener diode
PARTICULAR
USE
SENSORS
Tr : NPN output transistor
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
SENSING CHARACTERISTICS (TYPICAL)
WIRE-SAVING
SYSTEMS
GX-5SU GX-5SUB
MEASURE-
MENT
Sensing field
Correlation between sensing object size and sensing range
SENSORS
Standard sensing object Iron sheet
As the sensing object size becomes smaller than
the standard size (iron sheet 6 × 6 × t 1 mm
0.236 × 0.236 × t 0.039 in), the sensing range
shortens as shown in the left figure.
STATIC
CONTROL
DEVICES
Sensing object
6 × 6 × t 1 mm 0.236 × 0.236 × t 0.039 in
ℓ
a × a mm a × a in
2
2
t 1 mm t 0.039 in
L
L
0.079
0.079
ENDOSCOPE
Iron
LASER
Stainless steel
(SUS304)
MARKERS
1
1
0.039
0.039
PLC /
TERMINALS
Brass
Aluminum
HUMAN
MACHINE
0
INTERFACES
0
5
10
15
20
0.787
2
1
0
1
2
0.197
0.394
0.591
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
0.079
0.039
0.039
0.079
Sensing object side
length a (mm in)
Left
Center
Right
Operating point ℓ (mm in)
FA
GX-8MU GX-8MUB
COMPONENTS
MACHINE
VISION
Sensing field
Correlation between sensing object size and sensing range
SYSTEMS
Sensing object a × a mm a × a in
t 1 mm t 0.039 in
As the sensing object size becomes smaller than
the standard size (iron sheet 8 × 8 × t 1 mm
0.315 × 0.315 × t 0.039 in), the sensing range
shortens as shown in the left figure.
UV
CURING
L
Iron
SYSTEMS
2
2
Standard sensing
0.079
0.079
object Iron sheet
8 × 8 × t 1 mm
0.315 × 0.315 ×
t 0.039 in
Stainless steel
(SUS304)
ℓ
Selection
Guide
L
1
1
0.039
0.039
Brass
Amplifier
Built-in
Aluminum
Amplifier-
separated
0
5
10
15
20
0.787
4
2
0
2
4
0
0.197
0.394
0.591
0.157
0.079
0.079
0.157
GX-F/H
GXL
GL
Sensing object side
length a (mm in)
Left
Center
Right
Operating point ℓ (mm in)
GX-12MU(B) GX-F12MU-J
GX-U/GX-FU/
GX-N
Sensing field
Correlation between sensing object size and sensing range
GX
Sensing object a × a mm a × a in
t 1 mm t 0.039 in
As the sensing object size becomes smaller than
Standard sensing object Iron sheet
12 × 12 × t 1 mm 0.472 × 0.472 × t 0.039 in
the standard size (iron sheet 12 × 12 × t 1 mm
0.472 × 0.472 × t 0.039 in), the sensing range
shortens as shown in the left figure.
L
ℓ
4
4
L
0.157
0.157
Iron
Stainless steel
(SUS304)
2
2
Brass
Aluminum
0.079
0.079
0
4
2
0
2
4
10
20
30
40
0
0.157
0.079
0.079
0.157
0.394
0.787
1.181
1.575
Sensing object side
length a (mm in)
Left
Center
Right
Operating point ℓ (mm in)
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
804
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
LASER
SENSORS
GX-18MU(B) GX-F18MU-J
PHOTO-
ELECTRIC
SENSORS
Sensing field
Correlation between sensing object size and sensing range
MICRO
Standard sensing object Iron sheet
As the sensing object size becomes smaller than
Sensing object a × a mm a × a in
t 1 mm t 0.039 in
PHOTO-
ELECTRIC
SENSORS
18 × 18 × t 1 mm 0.709 × 0.709 × t 0.039 in
the standard size (iron sheet 18 × 18 × t 1 mm
0.709 × 0.709 × t 0.039 in), the sensing range
shortens as shown in the left figure.
L
ℓ
10
10
L
0.394
0.394
AREA
SENSORS
Iron
Stainless steel
LIGHT
CURTAINS
(SUS304)
5
5
0.197
0.197
PRESSURE /
FLOW
Brass
Aluminum
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
0
20
10
0
10
20
0.787
0
10
20
30
40
1.575
0.787
0.394
0.394
0.394
0.787
1.181
PARTICULAR
USE
Sensing object side
length a (mm in)
Left
Center
Right
SENSORS
Operating point ℓ (mm in)
SENSOR
OPTIONS
GX-30MU(B) GX-F30MU-J
SIMPLE
WIRE-SAVING
UNITS
Sensing field
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
WIRE-SAVING
SYSTEMS
Standard sensing object Iron sheet
30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
the standard size (iron sheet 30 × 30 × t 1 mm
1.181 × 1.181 × t 0.039 in), the sensing range
shortens as shown in the left figure.
MEASURE-
MENT
Iron
ℓ
10
10
L
0.394
0.394
SENSORS
Stainless steel
(SUS304)
STATIC
CONTROL
DEVICES
5
5
Brass
Aluminum
ENDOSCOPE
0.197
0.197
Sensing object a × a mm a × a in
t 1 mm t 0.039 in
L
LASER
MARKERS
0
20
10
0
10
20
0.787
0
20
40
60
2.362
80
PLC /
0.787
0.394
0.394
TERMINALS
0.787
1.575
3.150
Sensing object side
length a (mm in)
Left
Center
Right
HUMAN
Operating point ℓ (mm in)
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
GX-8MLU GX-8MLUB
Sensing field
Correlation between sensing object size and sensing range
FA
COMPONENTS
Sensing object a × a mm a × a in
t 1 mm t 0.039 in
As the sensing object size becomes smaller than
the standard size (iron sheet 20 × 20 × t 1 mm
0.787 × 0.787 × t 0.039 in), the sensing range
shortens as shown in the left figure.
MACHINE
VISION
L
Iron
SYSTEMS
4
4
0.157
0.157
UV
CURING
SYSTEMS
Stainless steel
(SUS304)
Standard sensing
object Iron sheet
20 × 20 × t 1 mm
0.787 × 0.787
× t 0.039 in
2
2
Brass
Aluminum
0.079
0.079
ℓ
Selection
Guide
L
Amplifier
Built-in
0
0
10
20
30
40
1.575
10
5
0
5
10
0.394
Amplifier-
separated
0.394
0.787
1.181
0.394
0.197
0.197
Sensing object side
length a (mm in)
Left
Center
Right
Operating point ℓ (mm in)
GX-F/H
GXL
GL
GX-12MLU GX-12MLUB
Sensing field
Correlation between sensing object size and sensing range
GX-U/GX-FU/
GX-N
Sensing object a × a mm a × a in
t 1 mm t 0.039 in
As the sensing object size becomes smaller than
the standard size (iron sheet 30 × 30 × t 1 mm
1.181 × 1.181 × t 0.039 in), the sensing range
shortens as shown in the left figure.
Standard sensing object Iron sheet
GX
30 × 30 × t 1 mm 1.181 × 1.181 × t 0.039 in
L
ℓ
10
10
L
0.394
0.394
Iron
Stainless steel
(SUS304)
5
5
0.197
0.197
Brass
Aluminum
0
20
10
0
10
20
20
40
60
80
3.150
0
0.787 0.394
Left
0.394
0.787
0.787
1.575
2.362
Sensing object side
length a (mm in)
Center
Right
Operating point ℓ (mm in)
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
805
FIBER
SENSING CHARACTERISTICS (TYPICAL)
SENSORS
LASER
SENSORS
GX-18MLU GX-18MLUB
PHOTO-
ELECTRIC
SENSORS
Sensing field
Correlation between sensing object size and sensing range
MICRO
PHOTO-
Standard sensing object Iron sheet
Sensing object a × a mm a × a in
t 1 mm t 0.039 in
As the sensing object size becomes smaller than
50 × 50 × t 1 mm 1.969 × 1.969 × t 0.039 in
ELECTRIC
SENSORS
the standard size (iron sheet 50 × 50 × t 1 mm
1.969 × 1.969 × t 0.039 in), the sensing range
shortens as shown in the left figure.
ℓ
L
20
20
L
0.787
0.787
AREA
SENSORS
Iron
Stainless steel
(SUS304)
LIGHT
CURTAINS
10
10
0.394
0.394
PRESSURE /
FLOW
Brass
Aluminum
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
0
20
10
0
10
20
0.787
20
40
60
80
3.150
0
0.787
0.394
0.394
PARTICULAR
USE
0.787
1.575
2.362
Sensing object side
length a (mm in)
Left
Center
Right
SENSORS
Operating point ℓ (mm in)
SENSOR
OPTIONS
GX-30MLU GX-30MLUB
SIMPLE
WIRE-SAVING
UNITS
Sensing field
Correlation between sensing object size and sensing range
WIRE-SAVING
SYSTEMS
As the sensing object size becomes smaller than
Iron
the standard size (iron sheet 70 × 70 × t 1 mm
2.756 × 2.756 × t 0.039 in), the sensing range
shortens as shown in the left figure.
MEASURE-
MENT
20
20
0.787
0.787
Stainless steel
(SUS304)
SENSORS
STATIC
CONTROL
DEVICES
Brass
Standard sensing object
Iron sheet 70 × 70 × t 1 mm
2.756 × 2.756 × t 0.039 in
10
10
ENDOSCOPE
Aluminum
0.394
0.394
Sensing object a × a mm a × a in
ℓ
t 1 mm t 0.039 in
L
L
LASER
MARKERS
0
20
10
0
10
0.394
Right
20
PLC /
20
40
60
80
0
0.787
TERMINALS
0.394
0.787
0.787
1.575
2.362
3.150
Sensing object side
length a (mm in)
Left
Center
HUMAN
MACHINE
Operating point ℓ (mm in)
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
GX-N12M GX-N12MB
Sensing field
Correlation between sensing object size and sensing range
FA
COMPONENTS
SIrotnasnhedeat 1r2d×s12e×nts1inmgm 0o.4b7j2e×c0t.472 × t 0.039 in
ℓ
As the sensing object size becomes smaller than
MACHINE
VISION
Sensing object a × a mm a × a in
the standard size (iron sheet 12 × 12 × t 1 mm
0.472 × 0.472 × t 0.039 in), the sensing range
shortens as shown in the left figure.
t 1 mm
SYSTEMS
L
4
4
t 0.039 in
L
0.157
0.157
UV
CURING
Iron
SYSTEMS
Stainless steel
(SUS304)
2
2
Brass
0.079
0.079
Aluminum
Selection
Guide
Amplifier
Built-in
0
4
2
0.079
Left
0
2
4
Amplifier-
0
10
20
30
40
separated
0.157
0.079
0.157
0.394
0.787
1.181
1.575
Sensing object side
length a (mm in)
Center
Operating point ℓ (mm in)
Right
GX-F/H
GXL
GL
GX-N18M GX-N18MB
Sensing field
Correlation between sensing object size and sensing range
GX-U/GX-FU/
GX-N
SIrotnasnhedeat 1r8d×s18e×nts1inmgm 0o.7b0j9e×c0t.709 × t 0.039 in
ℓ
As the sensing object size becomes smaller than
Sensing object a × a mm a × a in
GX
the standard size (iron sheet 18 × 18 × t 1 mm
0.709 × 0.709 × t 0.039 in), the sensing range
shortens as shown in the left figure.
t 1 mm
10
10
L
t 0.039 in
L
0.394
0.394
Iron
Stainless steel
(SUS304)
5
5
0.197
0.197
Brass
Aluminum
0
20
10
0.394
Left
0
10
20
0.787
0
10
20
30
40
0.787
0.394
0.394
0.787
1.181
1.575
Sensing object side
length a (mm in)
Center
Operating point ℓ (mm in)
Right
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
806
SENSING CHARACTERISTICS (TYPICAL)
FIBER
SENSORS
LASER
SENSORS
GX-N30M GX-N30MB
PHOTO-
ELECTRIC
SENSORS
Sensing field
Correlation between sensing object size and sensing range
As the sensing object size becomes smaller than
MICRO
SIrotnasnhedeat 3r0d×s30e×nts1inmgm 1o.1b8j1e×c1t.181 × t 0.039 in
PHOTO-
ELECTRIC
SENSORS
the standard size (iron sheet 30 × 30 × t 1 mm
1.181 × 1.181 × t 0.039 in), the sensing range
shortens as shown in the left figure.
Iron
ℓ
10
10
L
0.394
0.394
AREA
Stainless steel
(SUS304)
SENSORS
LIGHT
CURTAINS
5
5
Brass
0.197
0.197
PRESSURE /
FLOW
Aluminum
Sensing object a × a mm a × a in
SENSORS
L
t 1 mm
INDUCTIVE
PROXIMITY
SENSORS
t 0.039 in
0
0
20
40
60
80
3.150
20
10
0.394
Left
0
10
20
0.787
0.787
1.575
2.362
0.394
0.787
PARTICULAR
USE
Sensing object side
length a (mm in)
Center
Operating point ℓ (mm in)
Right
SENSORS
SENSOR
OPTIONS
GX-N12ML GX-N12MLB
Sensing field
SIMPLE
WIRE-SAVING
UNITS
Correlation between sensing object size and sensing range
WIRE-SAVING
SYSTEMS
As the sensing object size becomes smaller than
Sensing object a × a mm a × a in
SIrotnasnhedeat 3r0d× s30e×nts1inmmg1o.1b81je×c1t.181 × t 0.039 in
t 1 mm
the standard size (iron sheet 30 × 30 × t 1mm
1.181 × 1.181 × t 0.039 in), the sensing range
shortens as shown in the left figure.
L
MEASURE-
MENT
ℓ
t 0.039 in
10
10
L
0.394
0.394
SENSORS
Iron
STATIC
Stainless steel
(SUS304)
CONTROL
DEVICES
5
5
0.197
ENDOSCOPE
0.197
Brass
Aluminum
LASER
MARKERS
0
0
20
40
60
80
20
10
0.394
Left
0
10
20
PLC /
0.787
1.575
2.362
3.150
TERMINALS
0.787
0.394
0.787
Sensing object side
length a (mm in)
Center
Operating point ℓ (mm in)
Right
HUMAN
MACHINE
INTERFACES
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
GX-N18ML GX-N18MLB
Sensing field
Correlation between sensing object size and sensing range
FA
COMPONENTS
SIrotnasnhedeat 5r0d× s50e×nts1inmmg1o.9b69je×c1t.969 × t 0.039 in
ℓ
As the sensing object size becomes smaller than
Sensing object a × a mm a × a in
t 1 mm
MACHINE
VISION
the standard size (iron sheet 50 × 50 × t 1 mm
1.969 × 1.969 × t 0.039 in), the sensing range
shortens as shown in the left figure.
L
t 0.039 in
20
SYSTEMS
20
L
0.787
0.787
UV
CURING
SYSTEMS
Iron
Stainless steel
(SUS304)
10
10
0.394
0.394
Brass
Aluminum
Selection
Guide
Amplifier
Built-in
0
0
20
40
60
80
3.150
20
10
0.394
Left
0
10
20
0.787
Amplifier-
0.787
1.575
2.362
0.787
0.394
separated
Sensing object side
length a (mm in)
Center
Operating point ℓ (mm in)
Right
GX-F/H
GXL
GL
GX-N30ML GX-N30MLB
Sensing field
Correlation between sensing object size and sensing range
GX-U/GX-FU/
GX-N
As the sensing object size becomes smaller than
Iron
GX
the standard size (iron sheet 70 × 70 × t 1 mm
2.756 × 2.756 × t 0.039 in), the sensing range
shortens as shown in the left figure.
20
20
0.787
0.787
Stainless steel
(SUS304)
Brass
10
10
SIrotnasnhedeat 7r0d×s7e0 n× st 1inmgmo2.b75je6 c×t2.756 × t 0.039 in
0.394
0.394
Sensing object a × a mm a × a in Aluminum
t 1 mm
ℓ
L
L
t 0.039 in
0
0
20
40
60
80
20
10
0.394
Left
0
10
20
0.787
0.787
1.575
2.362
3.150
0.394
0.787
Sensing object side
length a (mm in)
Center
Operating point ℓ (mm in)
Right
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
807
FIBER
PRECAUTIONS FOR PROPER USE
Refer to General precautions.
SENSORS
LASER
All models
SENSORS
Distance from surrounding metal
PHOTO-
ELECTRIC
SENSORS
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
• As metal around the sensor may affect the sensing
performance, pay attention to the following points.
MICRO
PHOTO-
ELECTRIC
SENSORS
Influence of surrounding metal
AREA
SENSORS
• The surrounding metal will affect the sensing performance.
Keep the minimum distance specified in the table below.
LIGHT
CURTAINS
PRESSURE /
FLOW
Model No.
E (mm in)
Mounting
SENSORS
GX-5SU(B)
GX-8MU(B)
4.5 0.177
4.5 0.177
E
• The tightening torque should be under the value given below.
INDUCTIVE
PROXIMITY
SENSORS
Mounting with a set screw
GX-12MU(B)
GX-F12MU-J
GX-N12M(B)
GX-18MU(B)
GX-F18MU-J
GX-N18M(B)
GX-30MU(B)
GX-F30MU-J
GX-N30M(B)
PARTICULAR
USE
8 0.315
20 0.787
40 1.575
• Tighten with the cup-point of a set screw (M4).
SENSORS
<Non-threaded type>
Mounting hole process dimension
SENSOR
OPTIONS
Set screw
(M4)
A
C
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
GX-8MLU(B)
8 0.315
B
GX-12MLU(B)
GX-N12ML(B)
GX-18MLU(B)
GX-N18ML(B)
GX-30MLU(B)
GX-N30ML(B)
22 0.866
MEASURE-
MENT
Model No. A (mm in) B (mm in)
C (mm in) Tightening torque
SENSORS
45 1.772
75 2.953
ø5.5+ 0.2 ø0.217 + 0.008
GX-5SU(B) 5 to 30 0.197 to 1.181
3 0.118
0.78 N·m
STATIC
CONTROL
DEVICES
0
0
• Do not fix on the operation indicator or opposite to it.
ENDOSCOPE
Operation
indicator
Operation
indicator
Operation
indicator
Embedding of the sensor in metal
LASER
MARKERS
• Sensing range may decrease if the sensor is completely
embedded in metal. Especially for the non-threaded type
and the non-shielded type, keep the minimum distance
specified in the table below.
Set
screw
PLC /
TERMINALS
Mounting with nut
HUMAN
MACHINE
<Shielded of threaded type>
<Non-shielded of threaded type>
INTERFACES
Attached toothed
Attached toothed
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Model No.
GX-5SU(B)
F (mm in) G (mm in)
ø12 ø0.472 3 0.118
ø24 ø0.945 12 0.472
lock washer
D
lock washer
D
GX-8MLU(B)
FA
F
COMPONENTS
GX-12MLU(B)
GX-N12ML(B)
GX-18MLU(B)
GX-N18ML(B)
GX-30MLU(B)
GX-N30ML(B)
ø50 ø1.969 15 0.591
ø75 ø2.953 25 0.984
ø105 ø4.134 30 1.181
G
MACHINE
VISION
Metal
Mounting plate
Mounting plate
SYSTEMS
UV
CURING
Note: With the non-shielded type, the sensing
range may vary depending on the
position of the nuts.
Model No.
Dimension D (mm in)
3 to 10.3 0.118 to 0.406
10.3 0.406 or more
3.5 to 13.5 0.138 to 0.531
13.5 0.531 or more
4 to 18 0.157 to 0.709
18 0.709 or more
Tightening torque
5.9 N·m
SYSTEMS
GX-8MU(B)
11.8 N·m
10 N·m
GX-12MU(B)
GX-F12MU-J
GX-N12M(B)
GX-18MU(B)
GX-F18MU-J
GX-N18M(B)
GX-30MU(B)
GX-F30MU-J
GX-N30M(B)
Mutual interference
Selection
Guide
20 N·m
Amplifier
Built-in
• When two or more sensors are installed in parallel or
face to face, keep the minimum separation distance
specified below to avoid mutual interference.
45 N·m
Amplifier-
80 N·m
separated
5 to 21 0.197 to 0.827
21 0.827 or more
80 N·m
180 N·m
11.8 N·m
Face to face mounting
Model No.
H (mm in) J (mm in)
GX-F/H
GXL
GL
GX-8MLU(B)
12 0.472 or more
H
GX-5SU(B)
GX-8MU(B)
19 0.748 14 0.551
20 0.787 15 0.591
GX-12MLU(B)
GX-N12ML(B)
15 0.591 or more
25 0.984 or more
30 1.181 or more
20 N·m
80 N·m
GX-12MU(B)
GX-F12MU-J
GX-18MU(B)
GX-F18MU-J
GX-30MU(B)
GX-F30MU-J
GX-18MLU(B)
GX-N18ML(B)
35 1.378 20 0.787
70 2.756 45 1.772
GX-U/GX-FU/
GX-N
Parallel mounting
GX-30MLU(B)
GX-N30ML(B)
GX
180 N·m
115 4.528 70 2.756
60 2.362 45 1.772
Note: Mount such that the nuts do not protrude from the threaded portion.
J
GX-8MLU(B)
• The root truncation of the threads is shallow owing to
strengthening of the sensors against tightening.
When tapping holes on equipment to fix the sensors, the
prepared holes must be value in the table below.
GX-12MLU(B) 145 5.709 95 3.740
GX-18MLU(B) 250 9.843 165 6.496
GX-30MLU(B) 350 13.780 250 9.843
GX-N12M(B)
GX-N18M(B)
GX-N30M(B)
25 0.984 15 0.591
50 1.969 35 1.378
90 3.543 55 2.165
Model No.
Prepared hole
Tapping holes
GX-8MU(B)
GX-8MLU(B)
ø7.2 mm
ø0.283 in
Sensor
GX-12MU(B)
GX-12MLU(B)
GX-F12MU-J
GX-N12M(B)
GX-N12ML(B)
GX-N12ML(B) 120 4.724 70 2.756
GX-N18ML(B) 180 7.087 125 4.921
GX-N30ML(B) 290 1.417 190 7.480
ø11.2 mm
ø0.441 in
Tap
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
808
PRECAUTIONS FOR PROPER USE
FIBER
Refer to General precautions.
SENSORS
LASER
All models
DC 2-wire type
Wiring
SENSORS
Sensing range
PHOTO-
ELECTRIC
SENSORS
• The sensor must be connected to a power supply via a load.
If the sensor is connected to a power supply without a load,
the short-circuit protection makes the sensor inoperable.
(The output stays in the OFF state and the indicator does
not light up.) In this case, rectify by connecting the power
supply via a load. Now, the sensor becomes operable.
Further, take care that if the power supply is connected with
reverse polarity without a load, the sensor will get damaged.
• The sensing range is specified for the standard sensing
object. With a non-ferrous metal, the sensing range is
obtained by multiplying with the correction coefficient
specified below. Further, the sensing range also changes
if the sensing object is smaller than the standard sensing
object or if the sensing object is plated.
MICRO
PHOTO-
ELECTRIC
SENSORS
AREA
SENSORS
LIGHT
CURTAINS
PRESSURE /
FLOW
Correction coefficient
Blue lead wire
Brown lead wire
SENSORS
Metal
Stainless steel
INDUCTIVE
PROXIMITY
SENSORS
Iron
Brass
Aluminum
(SUS304)
Model No.
GX-5SU(B)
GX-8MU(B)
+
+
–
DC
power
supply
DC
power
supply
PARTICULAR
USE
1
1
0.63 approx. 0.32 approx. 0.30 approx.
0.59 approx. 0.32 approx. 0.29 approx.
–
SENSORS
SENSOR
OPTIONS
GX-12MU(B)
GX-F12MU-J
Brown lead wire
Blue lead wire
1
1
1
0.75 approx. 0.51 approx. 0.49 approx.
0.75 approx. 0.50 approx. 0.48 approx.
0.69 approx. 0.44 approx. 0.42 approx.
SIMPLE
• For series connection (AND circuit) or parallel connection
(OR circuit) of sensors, take care of the following.
WIRE-SAVING
UNITS
GX-18MU(B)
GX-F18MU-J
WIRE-SAVING
SYSTEMS
Series connection (AND circuit)
Parallel connection (OR circuit)
GX-30MU(B)
GX-F30MU-J
When all sensors are in the ON state,
the load voltage VRL is given by:
VRL = VCC – n × 3 (V)
Vcc: supply voltage
(24 V DC max.)
When all sensors are in the OFF state,
the load leakage current lcc is given by:
MEASURE-
MENT
SENSORS
GX-8MLU(B)
GX-12MLU(B)
GX-18MLU(B)
GX-30MLU(B)
GX-N12M(B)
GX-N18M(B)
GX-N30M(B)
GX-N12ML(B)
GX-N18ML(B)
GX-N30ML(B)
1
1
1
1
1
1
1
1
1
1
0.64 approx. 0.38 approx. 0.38 approx.
0.67 approx. 0.44 approx. 0.43 approx.
0.68 approx. 0.45 approx. 0.43 approx.
0.67 approx. 0.44 approx. 0.43 approx.
0.77 approx. 0.52 approx. 0.51 approx.
0.73 approx. 0.50 approx. 0.48 approx.
0.70 approx. 0.45 approx. 0.44 approx.
0.66 approx. 0.44 approx. 0.43 approx.
0.68 approx. 0.46 approx. 0.44 approx.
0.65 approx. 0.44 approx. 0.43 approx.
STATIC
lcc =n × 0.8 (mA) ( n: number of sensors)
Make sure that the load can work properly.
CONTROL
DEVICES
n: number of sensors
ENDOSCOPE
Note: The load current in the ON state
is given by:
Make sure that the load can
work properly at this voltage.
LASER
Vcc – 3V
Load resistance
MARKERS
I
L
=
(mA)
Note: The output is generated
normally even if the indicator
does not light up properly.
PLC /
The load current must be
3 mA × n ≤ IL ≤ 70 mA
(n: number of sensors turned ON)
TERMINALS
HUMAN
MACHINE
INTERFACES
Brown lead wire
Load
Brown lead wire
Load
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
Blue
I
CC
VRL
lead wire
(IL)
+
–
Blue lead wire
+
–
FA
V
CC
COMPONENTS
VCC
Brown
Brown
lead wire
Protection cover (Optional)
lead wire
MACHINE
VISION
SYSTEMS
Blue lead wire
Blue lead wire
• It protects the sensing surface from welding sparks
(spatter), etc.
UV
• The residual voltage of the sensor is 3 V. Before connecting
a relay as the load, take care of its actuation voltage.
(Some 12 V relays may not be usable.)
CURING
SYSTEMS
Mounting method
Protection
cover
Sensor
Model No.
Applicable model No.
Relay actuation
voltage:
GX-12MU(B)
GX-N12M(B)
Selection
Guide
V
R
Relay actuation
MS-H12
R
V ≤ 12 – 3 V
(
)
voltage
≤ 9 V
Amplifier
Built-in
+
–
Power supply
GX-18MU(B)
GX-N18M(B)
Brown lead wire
MS-H18
MS-H30
12 V DC
Amplifier-
separated
V
S
=3 V Residual voltage
Material: Fluorine resin
when the sensor
GX-30MU(B)
GX-N30M(B)
(is in the ON state)
Blue lead wire
GX-F/H
GXL
GL
Note: Mount the protection cover so that there is no gap between it and the
sensing surface.
2-color indicator [GX-(F)□U(-J) only]
• When the sensing object is in the stable sensing range,
the LED lights up in green, and when the sensing object
is in the unstable sensing range, the LED lights up in
orange. While the LED lights up in green, the sensing is
performed stably without being affected by temperature
drifts or voltage fluctuations.
GX-U/GX-FU/
GX-N
Others
GX
• Do not use during the initial transient time (50 ms) after
the power supply is switched on.
• Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
Max.
Output operation
operation
level
distance
Unstable range
LED lights up
in orange
0
Output operation
2-color indicator operation
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
809
FIBER
DIMENSIONS (Unit: mm in)
The CAD data in the dimensions can be downloaded from our website.
SENSORS
LASER
SENSORS
Sensor
Sensor
GX-5SU GX-5SUB
GX-8MU GX-8MUB
PHOTO-
ELECTRIC
SENSORS
30
1.181
1.5
Indicator part
2-color indicator
(Orange, green) (Note)
ø5.4
2-color indicator
(Orange, green) (Note)
ø0.213
01.3094
MICRO
PHOTO-
20
12
0.059
M8 × 1 0.039
0.472
ø6.8
0.787
ELECTRIC
SENSORS
ø0.268
ø15
Toothed
ø2.9 ø0.114 cable, 2 m 6.562 ft long
4
16.5
0.650
AREA
ø0.591
lock washer
(Internally toothed)
SENSORS
0.157
3
ø2.9 ø0.114 cable, 2 m 6.562 ft long
0.118
Note: GX-5SUB has an operation indicator (orange) instead of the
LIGHT
2-color indicator.
Note: GX-8MUB has an operation indicator (orange) instead of the 2-color
CURTAINS
indicator.
PRESSURE /
FLOW
SENSORS
Sensor
Sensor
GX-12MU(B) GX-N12M(B)
GX-18MU(B) GX-N18M(B)
INDUCTIVE
PROXIMITY
SENSORS
5
Indicator part
Indicator part
5
0.197
0.197
2
24
36.5
2
1.3
35.5
1.3
17
PARTICULAR
USE
0.079
0.945
1.437
0.079
0.051
1.398
0.051
0.669
SENSORS
M18 × 1 0.039
M12 × 1 0.039
ø5.5
ø5.5
ø0.217
ø0.217
SENSOR
OPTIONS
ø10.4
ø0.409
ø10.4
ø0.409
ø21
ø29
ø0.827
ø3.6 ø0.142 cable,
SIMPLE
WIRE-SAVING
UNITS
ø3.6 ø0.142 cable,
2 m 6.562 ft long
ø1.142
2 m 6.562 ft long
3.5
Toothed lock washer
(Internally toothed)
2-color indicator
0.138
4
2-color indicator
Toothed lock washer
(Orange, green) (Note)
0.157
(Orange, green) (Note)
WIRE-SAVING
SYSTEMS
(Internally toothed)
Note: GX-12MUB and GX-N12M(B) have an operation indicator (orange)
Note: GX-18MUB and GX-N18M(B) have an operation indicator (orange)
MEASURE-
MENT
instead of the 2-color indicator.
instead of the 2-color indicator.
SENSORS
STATIC
CONTROL
DEVICES
Sensor
Sensor
GX-30MU(B) GX-N30M(B)
GX-8MLU GX-8MLUB
Indicator part
5
Indicator part
ENDOSCOPE
0.197
2
36
39.5
1.3
2-color indicator
(Orange, green) (Note)
0.079
1.417
1.555
0.051
12
10
20
M8 × 1 0.039
0.472
M30 × 1.5 0.059
0.394
0.787
LASER
MARKERS
ø6.5
ø5.5
ø0.217
ø15
ø0.256
ø6.8
ø0.268
ø2.9 ø0.114 cable, 2 m 6.562 ft long
6
ø0.591
Toothed
lock washer
(Internally toothed)
PLC /
ø10.4
0.236
TERMINALS
ø
0.409
3
0.118
HUMAN
MACHINE
ø43
Note: GX-8MLUB has an operation indicator (orange) instead of the 2-color
ø3.6 ø0.142 cable,
2 m 6.562 ft long
INTERFACES
ø1.693
indicator.
ENERGY
CONSUMPTION
VISUALIZATION
COMPONENTS
5
Toothed lock washer
(Internally toothed)
2-color indicator
0.197
(Orange, green) (Note)
Note: GX-30MUB and GX-N30M(B) have an operation indicator (orange)
FA
COMPONENTS
instead of the 2-color indicator.
MACHINE
VISION
SYSTEMS
Sensor
Sensor
GX-12MLU(B) GX-N12ML(B)
GX-18MLU(B) GX-N18ML(B)
UV
CURING
Indicator part
Indicator part
5
5
SYSTEMS
0.197
0.197
35.5
17
2
1.3
24
36.5
2
1.3
1.398
0.669
0.079
0.051
0.945
1.437
0.079
0.051
7
10
M12 × 1 0.039
0.276
0.394
ø5.5
M18 × 1 0.039
ø5.5
ø0.217
ø0.217
ø10.2
ø10.4
ø15.2
ø10.4
Selection
Guide
ø0.402
ø0.409
ø0.409
ø0.598
ø3.6 ø0.142 cable,
2 m 6.562 ft long
Toothed lock washer
(Internally toothed)
ø21 ø0.827
Amplifier
Built-in
ø3.6 ø0.142 cable,
2 m 6.562 ft long
ø29 ø1.142
3.5
0.138
2-color indicator
Amplifier-
2-color indicator
Toothed lock washer
4
(Orange, green) (Note)
separated
(Orange, green) (Note)
(Internally toothed)
0.157
Note: GX-12MLUB and GX-N12ML(B) have an operation indicator (orange)
Note: GX-18MLUB and GX-N18ML(B) have an operation indicator (orange)
GX-F/H
GXL
GL
instead of the 2-color indicator.
instead of the 2-color indicator.
Sensor
Sensor
GX-30MLU(B) GX-N30ML(B)
GX-12MU(B)-J GX-F12MU-J
GX-U/GX-FU/
GX-N
Indicator part
5
Indicator part
5
0.197
36
39.5
1.3
2
0.197
(300)
35.5
1.3
17
GX
1.417
1.555
0.051
0.079
12
1.398
(11.811)
0.051
0.669
2
44
0.472 M30 × 1.5 0.059
M12 × 1 0.039
0.079
1.732
ø5.5
ø0.217
ø14
ø0.551
ø21
ø26.6
ø1.047
ø10.4
ø10.4
M12
ø0.827
ø5.5
ø0.409
ø0.409
connector
ø0.217
3.5
0.138
ø3.6 ø0.142 cable
2-color
ø3.6 ø0.142 cable,
2 m 6.562 ft long
indicator
ø43 ø1.693
Toothed lock washer
(Internally toothed)
(Orange, green) (Note)
Toothed lock washer
(Internally toothed)
2-color indicator
(Orange, green) (Note)
5
0.236
Note: GX-30MLUB and GX-N30ML(B) have an operation indicator (orange)
Note: GX-12MUB-J has an operation indicator (orange) instead of the 2-color
instead of the 2-color indicator.
indicator.
Cylindrical Inductive Proximity Sensor GX-USERIES GX-FUSERIES GX-NSERIES
810
DIMENSIONS (Unit: mm in)
FIBER
The CAD data in the dimensions can be downloaded from our website.
SENSORS
LASER
SENSORS
Sensor
Sensor
GX-18MU(B)-J GX-F18MU-J
GX-30MU(B)-J GX-F30MU-J
PHOTO-
ELECTRIC
SENSORS
Indicator part
Indicator part
5
5
0.197
0.197
(300)
(300)
36.5
36
39.5
1.3
24
1.3
MICRO
(11.811)
1.555
(11.811)
PHOTO-
ELECTRIC
SENSORS
1.437
1.417
0.051
0.945
0.051
2
2
44
44
M30 × 1.5 0.059
M18 × 1 0.039
0.079
0.079
ø5.5
ø0.217
1.732
1.732
ø5.5
ø0.217
AREA
ø14
SENSORS
ø14
ø0.551
ø0.551
M12
ø29
ø10.4
M12
connector
LIGHT
ø10.4
ø0.409
ø1.142
ø0.409
2-color
connector
CURTAINS
ø43
ø3.6 ø0.142 cable
i(nOdraincgaet,ogrreen) (Note)
4
ø1.693
ø3.6 ø0.142 cable
0.157
2-color
PRESSURE /
FLOW
Toothed lock washer
(Internally toothed)
5
indicator
Toothed lock washer
(Internally toothed)
0.197
(Orange, green) (Note)
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Note: GX-18MUB-J has an operation indicator (orange) instead of the
Note: GX-30MUB-J has an operation indicator (orange) instead of the
2-color indicator.
2-color indicator.
PARTICULAR
USE
SENSORS
Sensor
Sensor
GX-12MLU-J GX-12MLUB-J
GX-18MLU-J GX-18MLUB-J
SENSOR
OPTIONS
5
Indicator part
5
Indicator part
SIMPLE
0.197
(300)
0.197
17
35.5
(300)
24
36.5
1.3
WIRE-SAVING
UNITS
1.3
0.669
1.398
(11.811)
2
7
0.945
1.437
(11.811)
0.051
0.051
2
44
44
10
0.276
0.079
M12 × 1 0.039
0.079
1.732
M18 × 1 0.039
1.732
0.394
ø10.2
ø0.402
ø5.5
ø0.217
ø5.5
ø0.217
WIRE-SAVING
SYSTEMS
ø14
ø0.551
ø14
ø15.2
ø0.551
ø0.598
MEASURE-
MENT
M12
connector
M12
ø21 ø0.827
ø10.4
ø10.4
connector
ø29 ø1.142
SENSORS
ø0.409
ø0.409
2-color indicator
3.5
ø3.6 ø0.142 cable
ø3.6 ø0.142 cable
(Orange, green) (Note)
4
0.138
STATIC
2-color indicator
(Orange, green)
(Note)
Toothed lock washer
0.157
CONTROL
DEVICES
Toothed lock washer
(Internally toothed)
(Internally toothed)
ENDOSCOPE
Note: GX-12MLUB-J has an operation indicator (orange) instead of the
Note: GX-18MLUB-J has an operation indicator (orange) instead of the
2-color indicator.
2-color indicator.
LASER
MARKERS
Sensor
GX-30MLU-J GX-30MLUB-J
PLC /
TERMINALS
HUMAN
Indicator part
5
MACHINE
INTERFACES
0.197
(300)
36
39.5
1.3
1.417
1.555
2
(11.811)
0.051
12
44
ENERGY
0.079
ø5.5
0.472
1.732
M30
×
1.5 0.059
CONSUMPTION
VISUALIZATION
COMPONENTS
ø14
ø0.551
ø0.217
ø26.6
ø1.047
FA
COMPONENTS
M12
ø10.4
ø0.409
connector
MACHINE
VISION
ø43 ø1.693
ø3.6 ø0.142 cable
Toothed lock washer
5
2-color indicator
(Orange, green)
(Note)
SYSTEMS
0.197
(Internally toothed)
UV
CURING
SYSTEMS
Note: GX-30MLUB-J has an operation indicator (orange) instead of the
2-color indicator.
Sensor mounting bracket for GX-5SU(B) (Optional)
Protection cover (Optional)
Selection
Guide
MS-SS5
MS-H12 MS-H18 MS-H30
Amplifier
Built-in
2-ø3.5 ø0.138
mounting holes
Thickness of
front face
Amplifier-
separated
A
8.3
0
0.327
0.7– 00.2
0.028 – 0.008
GX-F/H
GXL
GL
B C
18
10
0.709
0.394
4 0.157
GX-U/GX-FU/
GX-N
Material: Fluorine resin
4
4
8
GX
0.157
0.157
0.315
16
Symbol
6.1
Applicable
model No.
A
B
C
0.240
0.630
Model No.
Material: Nylon 66
ø11.5
ø0.453 ø0.551
ø14
GX-12MU(B)
GX-N12M(B)
5
6
8
MS-H12
ø17.5 ø20
GX-18MU(B)
GX-N18M(B)
MS-H18
MS-H30
ø0.689 ø0.787
ø29.4 ø33
GX-30MU(B)
GX-N30M(B)
ø1.157 ø1.299
相关型号:
©2020 ICPDF网 联系我们和版权申明