GX15B [ETC]
GAS, AIR PROBE;Temperature
Probes
Probe Tips
Penetration / Immersion
Type “F”
20 Pointed penetration
21 Tapered penetration
22 Chisel penetration
24 Rounded Immersion
26 Corkscrew penetration
28 Alligator Immersion
Surface/Contact
Type “C”
30 Flat disk (Thermistor)
32 Ribbon
34 Between pack
36 Heavy duty spring
Air/Gas
Type “G”
40 Air (Thermistor)
42 Beaded thermocouple
44 Hooded
46 Caged
48 Caged with rack clip
Sub-Mini Connector
Lumberg Connector
Bipolar
Connectors
Three Year Limited Warranty on TPI Products
Temperature Probe
Catalog V101
Copyright © 2008 Test Products International, Inc.
www.tpi-thevalueleader.com • 503.520.9197
Probe Tips
Probe Type
F: Penetration/immersion
C: Contact/Surface
G: Air/Gas
Penetration / Immersion
Type “F”
20 Pointed penetration
21 Tapered penetration
Sensor Type
Connector Type
M- Sub-miniature
L- Lumberg connector
B- Bipole
22 Chisel penetration
K: Type K-thermocouple
T: Type T-thermocouple
J: Type J-thermocouples
X: Thermistor (PST)
24 Rounded Immersion
26 Corkscrew penetration
28 Alligator Immersion
21 M
F K
Surface/Contact
Type “C”
30 Flat disk (Thermistor)
Sequential Number
32 Ribbon
34 Between pack
What is the difference between thermocouple and thermistor probes?
Thermocouple probes utilize the reaction between two dissimilar metals to produce a voltage that changes as
temperature changes. A thermistor is a resistive with a change in temperature. In general, thermocouples
offer a wider temperature range and quicker response time than thermistors. Thermistors are typically more
accurate than thermocouples.
36 Heavy duty spring
What are the differences between thermocouple types?
Each thermocouple uses different metals and there fore have different characteristics. Here are general
guidelines:
Air/Gas
Type “G”
40 Air (Thermistor)
K-Type- Wide temperature range used in many digital thermometers. Identified by a yellow connector.
T-Type- Narrower temperature range than J-type but more accurate than K and J types, used in digital
thermometers. Identified by a blue connector.
J-Type- Narrower temperature reange the K-Type used in analog and digital thermometers. Identified by
a black connector.
42 Beaded thermocouple
44 Hooded
46 Caged
48 Caged with rack clip
Can different thermocouple types be interchanged?
No. Since each thermocouple type uses different metals in it’s construction they have different output
characteristics. Using a J-type thermocouple in a K-type thermometer will cause measurements to be very
inaccurate.
Sub-Mini
Connector
What are the differences between the connector types TPI offers?
Sub-Mini- This is an industry standard connector type allowing TPI probes to be used in any thermocouple
thermometer using this type of connector. Sub-mini connectors are quick and easy to use, simply push in and
out. A wide variety of economical probes are available with sub-mini connectors, enhancing versatility and
affordability of the temperature tester.
Lumberg- This connector uses a screw collar to attach to the thermometer and is the most secure connection
available. Lumberg connectors are designed for the rigors of food processing environments. Advantages
include:
Lumberg
Connector
• Strong connection - stainless steel collar holds and protects connection. Probe will not
pull out of instrument with out unscrewing the collar.
• Waterproof stainless steel will not rust and is ideal for wet, humid conditions
• Lumberg connectors are manufactured following ISO9000 quality control guidelines.
Bi-Polar- This connector is used in the TPI thermistor probe line.
Bipolar
Connectors
REFER TO THE TPI WEBSITE FOR ADDITIONAL OR OEM PROBE OPTIONS
2
Copyright © 2008 Test Products International, Inc.
www.tpi-thevalueleader.com • 503.520.9197
Penetration / Immersion Probe Applications (F)
Contact/Surface Probe Applications (C)
• Check internal food temperatures to assure quality control.
• Measure deep fat fryers with a high temp immersion probe.
• Measure liquids and semi-solid temperatures in food processing applications.
• Use a reduced tip probe for quicker response times where time is crucial to
the process.
• Measure grill temperature to assure correct cooking temperatures.
• Check frozen food to assure proper storage temperatures.
• Measure temperatures between package to ensure proper
quality control.
• Check any surface for correct process control temperatures.
• Measure superheats on condensers.
Air/Gas Probe Applications. (G)
• Measure air temperatures in duct work.
• Measure air temperature coming from diffusers while Trouble-shooting heating
and air conditioning systems.
• Measure flame temperatures to trouble-shoot industrial heating applications.
• Calibrate thermostats using an ambient air probe.
• Measure griddle temperature.
• Measure mackinery or mold temperature with a surface probe.
• Measure pipe temperatures in any industrial application.
Contact/ Immersion (C)
Air/Gas (G)
Penetration/Immersion (F)
Probe
Tips
Designed to measure surface temperatures
Measure air or gas temperatures
Use for penetation into solids and immersion
into semi-solids & liquids.
Pointed: Can be used in air with slower response
Chisel: Can be used in air and on surfaces with
slower response
Tapered: Heavy duty, large diameter shaft for
bend resistant
Ribbon: Fast response.
Spring: Heavy duty sensing element for higher
surface temperatures
Beaded: Flexible, can be used in some liquid
immersion applications
Hooded: Rigid, hood provides protection for the
sensing element.
Caged: Rigid, cage provides maximum protec-
tion for the sensing element.
What type of probe should I use?
The type of probe you use depends upon your application. Here are some general guidelines for different types of probes.
Penetration/Immersion (F) General purpose probe used for penetration and immersion; can be used for air, but is much slower than an air probe.
Need to select the tip type that best cuits the application.
Contact/Surface (C) Contact probes are used to measure surface temperatures. Penetration probes, with the exception of the chisel tip, can’t measure
surface temperatures. Need to select the tip type that best suits the application
Air/Gas (G) Air probes measure the air or gas temperatures. They respond significantly faster than penetration or contact probes in air. Need to select
the tip type that best fits the application.
K-Type Thermocouple with Sub-Mini Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Stem Length: 4" (102mm)
Contact tempera-
tures on flat and
uneven surfaces
CK11M
Contact surface
probe, water proof
-58° to 500°F
-50° to 250°C
Diameter:
0.13" (3.2mm)
Polyurethane
Polyurethane
Polyurethane
Polyurethane
N/A
32
32
36
36
36
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 4" (102mm) w/90° bend
Diameter: 0.3" (7.5mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 4" (102mm)
Diameter: 0.6" (14mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 6" (152mm) w/90° bend
Diameter: 0.6" (14mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 8" (203mm)
Diameter: 0.6" (14mm)
Lead Length: N/A
IP Rating: N/A
CK12M
Contact tempera-
tures on flat and
uneven surfaces
-58° to 500°F
-50° to 250°C
Contact surface
probe, right angle,
waterproof
Contact tempera-
tures on flat and
uneven high tem-
perature surfaces
CK13M
Heavy-duty contact
surface probe
-58° to 1202°F
-50° to 650°C
CK14M
Contact tempera-
-58° to 1202°F
-50° to 650°C
Right angle heavy- tures on flat and
duty contact surface uneven high tem-
probe
CK15M
perature surfaces
Contact tempera-
-40° to 950°F
-40° to 510°C
Heavy-duty contact tures on flat and
surface probe for uneven high tem-
HK11M handle
perature surfaces
REFER TO THE TPI WEBSITE FOR ADDITIONAL OR OEM PROBE OPTIONS
Copyright © 2008 Test Products International, Inc.
3
www.tpi-thevalueleader.com • 503.520.9197
K-Type Thermocouple with Sub-Mini Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Contact tempera-
tures on flat and
uneven high tem-
perature surfaces
Stem Length: 8" (203mm)
CK16M
Heavy-duty contact
surface probe
-40° to 950°F
-40° to 510°C
Diameter:
0.6" (14mm)
36
32
32
N/A
N/A
32
32
20
21
20
20
20
21
21
28
21
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
N/A
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 4" (102mm) w/45° bend
Diameter: 0.3" (7.5mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
CK17M
Contact surface
probe, 45 degree
angle
Contact tempera-
tures on flat and
uneven surfaces
-40° to 500°F
-50° to 250°C
Stem Length: N/A
CK18M
Contact surface
probe
Contact temper-
atures on flat
surfaces
-58° to 500°F
-50° to 250°C
Nomin:
2.36" (60mm)
Lead Length: 39.4" (1M)
IP Rating:
N/A
Max jaw opening:
0.79"
Clamp probe for
pipe tempera-
tures
CK20M
Pipe clamp probe
-58° to 212°F
-50° to 100°C
Nominal jaw opening: 0.25"
Lead Length:
IP Rating:
Max jaw opening:
Nominal jaw opening: 0.75"
39.4" (1M)
N/A
1.2"
Clamp probe for
pipe tempera-
tures
CK21M
Pipe clamp probe
-58° to 212°F
-50° to 100°C
Lead Length:
IP Rating:
39.4" (1M)
N/A
CK22M
Fast response contact
Contact temper-
atures on flat
surface probe, 45 degree and uneven sur-
Stem Length: 4.5" (114mm) w/45° bend
Diameter: 0.5" (12.7mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 4.9" (125mm) w/90° bend
Diameter: 0.5" (12.7mm)
-58° to 500°F
-50° to 250°C
angle swivel head sensor
faces
Contact temper-
atures on flat
CK23M
Fast response contact
-58° to 500°F
-50° to 260°C
surface probe, 90 degree and uneven sur-
Lead Length: 39.4" (1M)
IP Rating:
angle swivel head sensor
faces
General purpose
penetration into
semi-solids and
liquids
Stem Length: 4" (102mm)
FK11M
Chisel tip penetra-
tion probe
-58° to 500°F
-50° to 250°C
Diameter:
0.13" (3.2mm)
Lead Length: 39.4" (1M)
IP Rating: 67
Heavy duty penetra-
Stem Length: 11.8" (300mm)
FK12M
Pointed tip tapered
penetration probe
tion into semi-solids -58° to 500°F
Diameter:
0.25 / 0.10" (6.4 / 2.5mm)
and liquids tapered
-50° to 250°C
Lead Length: 39.4" (1M)
shaft resist bending
IP Rating:
67
FK13M
General purpose
Pointed tip penetra- penetration into
Stem Length: 8" (203mm)
Diameter: 0.15" (3.75mm)
Lead Length: N/A
IP Rating: 67
Stem Length: 8" (203mm)
Diameter: 0.15" (3.75mm)
Lead Length: 39.4" (1M)
IP Rating: 67
Stem Length: 3.75" (80mm)
Diameter: 0.06 (1.6mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
-40° to 1562°F
-40° to 850°C
tion probe for
HK11M handle
semi-solids and
liquids
General purpose
penetration into
semi-solids and
liquids
FK14M
Chisel tip penetra-
tion probe
-40° to 1562°F
-40° to 850°C
Polyurethane
Teflon
Food temperature
measurements
and other light
FK15M
-58° to 500°F
-50° to 250°C
Tapered tip low mass
quick response pene-
tration probe
duty applications
Stem Length: 4.” (101.6mm)
General purpose light
duty penetration
applications requiring
fast response
FK21M
Tapered chisel tip
penetration probe
-58° to 500°F
-50° to 250°C
Diameter:
0.13”/.06” (3.2/1.6mm)
Polyurethane
Teflon
Lead Length: 39.4” (1M)
IP Rating:
67
Stem Length: 4" (101.6mm)
General purpose light
duty penetration
applications requiring
fast response
FK22M
Pointed tip penetra-
tion probe
-58° to 500°F
-50° to 250°C
Diameter:
0.09/0.06" (3.2/2.5mm)
Lead Length: 39.4" (1M)
IP Rating:
N/A
Stem Length: N/A
Diameter: N/A
Lead Length: 177" (4.5M)
IP Rating: 67
General purpose
air / liquid probe
with clip
FK23M
Rack clamp probe
-40° to 950°F
-40° to 510°C
Teflon
FK24M
General purpose
Stem Length: 24" (610mm)
-40° to 500°F
-40° to 250°C
Heavy duty T-handle penetration into
long stem penetra- semi-solids and
Diameter:
0.37"/0.15" (9.5mm/3.76mm)
Polyurethane
Lead Length: 39.4" (1M)
tion probe
liquids
IP Rating:
67
REFER TO THE TPI WEBSITE FOR ADDITIONAL OR OEM PROBE OPTIONS
4
Copyright © 2008 Test Products International, Inc.
www.tpi-thevalueleader.com • 503.520.9197
K-Type Thermocouple with Sub-Mini Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Stem Length: N/A
FK25M
Flat sensor
pack probe
Between pack -40° to 400°F
temperatures -40° to 204°C
Diameter: N/A
Lead Length: 39.4" (1.2M)
IP Rating: 67
Stem Length: 3" (76mm)
Diameter: 0.12" (3mm)
Lead Length: 39.4" (1M)
IP Rating: 67
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Polyurethane
Fiberglass
34
24
21
22
22
22
26
24
42
42
42
44
46
46
48
42
FK26M
Petes plug probe
Petes plug
-40° to 400°F
temperatures -40° to 204°C
FK27M
General purpose
Stem Length: 11.8" (300mm)
-58° to 500°F
-50° to 250°C
Waterproof long penetration into
stem heavy duty semi-solids and
Diameter:
0.25"/0.10" (6.4mm/2.5mm)
Lead Length: 39.4" (1M)
penetration probe
liquids
IP Rating:
67
Heavy duty penetra-
Stem Length: 6.3" (160mm)
Diameter: 0.13" (3.2mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 6.3" (160mm)
Diameter: 0.13" (3.2mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 24" (609.60mm)
Diameter: 0.38" (9.5mm)
Lead Length: 39.4” (1M)
IP Rating: 67
Stem Length: 4.5" (114mm)
Diameter: 0.20" (5mm)
Lead Length: 39.4" (1M)
IP Rating: 67
FK28M
Heavy duty
penetration probe
tion into semi-solids -58° to 500°F
and liquids tapered
-50° to 250°C
shaft resist bending
General purpose
FK29M
Long stem pointed
tip penetration probe
-58° to 500°F
-50° to 250°C
penetration into
semi-solids and
liquids
Heavy duty penetra-
FK30M
tion into semi-solids -58° to 500°F
Long stem heavy
duty T-handle pene-
tration probe
and liquids tapered
-50° to 250°C
shaft resist bending
FK31M
General purpose
-58° to 500°F
T-handle corkscrew penetration into
insertion probe
-50° to 250°C
semi-solids
Must be used with EXT31M extension (included)
Heavy duty penetra-
FK32M
Stem Length: 18" (457mm)
tion into semi-solids -58° to 500°F
Long stem heavy
duty T-handle pene-
tration probe
Diameter:
0.37"/0.15" (9.5mm/3.76mm)
and liquids tapered
-50° to 250°C
Lead Length: 39.4" (1M)
shaft resist bending
IP Rating:
67
Stem Length: N/A
Exposed junction for
GK11M
General purpose
beaded tip probe
-40° to 950°F
Diameter:
28 gauge
fast response in non-
food liquid, air and
-40° to 510°C
Lead Length: 48" (1.2M)
surface applications
IP Rating:
N/A
GK12M
Exposed junc-
Stem Length: N/A
-40° to 950°F
-40° to 510°C
General purpose
beaded tip probe
with rack clip
tion for fast
response in air
applications.
Diameter:
20 gauge
Fiberglass
Lead Length: 48" (1.2M)
IP Rating:
N/A
Exposed junction
for fast response in
food and non-food
liquid, air and sur-
face applications
Stem Length: N/A
GK13M
General purpose
beaded tip probe
-40° to 400°F
-40° to 204°C
Diameter:
24 gauge
Teflon
Lead Length: 48" (1.2M)
IP Rating:
N/A
Exposed junc-
tion for fast
response in air
applications.
Stem Length: 3.74" (95mm)
Diameter: 0.13" (3.75mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 8" (203mm)
Diameter: 0.26" (6.5mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: 8" (203mm)
Diameter: 0.26" (6.5mm)
Lead Length: 39.4" (1M)
IP Rating: N/A
Stem Length: N/A
Diameter: N/A
Lead Length: 39.4" (1M)
IP Rating: N/A
GK14M
Rigid stem hooded
exposed tip probe
-58° to 910°F
-40° to 510°C
Polyurethane
N/A
GK16M
Caged exposed
junction for fast
response in air
-40° to 500°F
-40° to 260°C
General purpose caged
air probe for use with
HK11M handle
GK17M
Caged exposed
-40° to 500°F
-40° to 260°C
General purpose junction for fast
caged air probe
Polyurethane
response in air
GK18M
Caged exposed
junction for fast
response in air
-40° to 586°F
-40° to 308°C
Braided
stainless steel
General purpose caged
air probe with rack clip
and armored cable
Exposed junction
for fast response in
non-food liquid, air
and surface appli-
cations
GK19M
Stem Length: N/A
-40° to 950°F
-40° to 510°C
Braided
stainless steel
General purpose
beaded tip probe
with armored cable
Diameter:
28 gauge
Lead Length: 48" (1.2M)
IP Rating:
N/A
REFER TO THE TPI WEBSITE FOR ADDITIONAL OR OEM PROBE OPTIONS
Copyright © 2008 Test Products International, Inc.
5
www.tpi-thevalueleader.com • 503.520.9197
K-Type Thermocouple with Sub-Mini Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Exposed junction
with cone stop, fast
response in flue
temperature
Stem Length: 4.33" (110mm)
GK20M
Flue temperature
probe
-40° to 932°F
-40° to 260°C
Diameter:
0.24" (6mm)
Teflon
42
Lead Length: 16' (4.9M)
IP Rating: N/A
applications
Stem Length: NA
Diameter: NA
Lead Length: 39.4” (1M)
IP Rating: N/A
EXT 31M
Male to Male
Extension
Use with
FK31M
N/A
N/A
Polyurethane
Polyurethane
N/A
N/A
HK11M
Stem Length: N/A
Diameter: N/A
Use with
FK13M, CK15M,
and GK16M
Handle for use with
K-type interchange-
able probe tips
Lead Length: 39.4" (1M)
IP Rating:
N/A
J-Type Thermocouple with Sub-Mini Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
GJ11M
Stem Length: N/A
Diameter: 24 Gauge
Lead Length: 1.2
IP Rating: N/A
Exposed junc-
tion for fast
response
-40° to 950°F
-40° to 500°C
Standard fiberglass
insulation, 4 foot, bead-
ed end (disposable)
Fiberglass
Fiberglass
Oven clip to
shield sensor
from direct
Stem Length: N/A
GJ12M
GJ11M with
oven clip
-40° to 950°F
-40° to 500°C
Diameter:
24 Gauge
Lead Length: 1.2
radiated heat
IP Rating:
N/A
K-Type Thermocouple with Lumberg Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
FK21L
Stem Length: 4” (101.6mm)
Food
Penetration
-58° to 500°F
-50° to 250°C
Contact surface
probe with ribbon
sensor. Water proof
Diameter:
0.13/.06” (3.2/1.6mm)
Polyurethane
Teflon
21
20
21
34
20
Lead Length: 39.4” (1M)
IP Rating:
67
Stem Length: 4”(101.6mm)
Testing food
temperatures
during cooking
FK22L
Oven food probe
-58° to 500°F
-50° to 250°C
Diameter:
0.09/.06” (3.2/1.6mm)
Lead Length: 47.2” (1.2M)
IP Rating:
FK23L
Immersion /
Penetration probe
no handle or lead
Stem Length: 3.9”(100mm)
Food
Penetration
-58° to 500°F
-50° to 250°C
Diameter:
0.15” (3.75mm)
NA
Lead Length: NA
IP Rating: 67
Stem Length: NA
Diameter: NA
Lead Length: 47.2” (1.2M)
IP Rating: 67
FK25L
Flat sensor pack
probe
-40° to 400°F
-40° to 204°C
Between pack
Teflon
Stem Length: 4”(101.6mm)
FK26L
Food
Penetration
-58° to 500°F
-50° to 250°C
Diameter:
.09/.06” (2.4/1.6mm)
Immersion /
Polyurethane
Lead Length: 39.4” (1M)
Penetration probe
IP Rating:
67
T-Type Thermocouple with Lumberg Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Stem Length: 4”(102mm)
CT11L
Surface
-58° to 500°F
-50° to 250°C
Diameter:
0.13” (3.2mm)
Surface probe with Temperatures
ribbon sensor
PVC
32
22
Lead Length: 39.4” (1M)
IP Rating: N/A
Grills
General purpose
penetation into
semi-solids and
liquids
Stem Length: 4”(101.6mm)
FT11L
Chisel tip penetra-
tion probe
-148° to 500°F
-100° to 250°C
Diameter:
0.13/.15” (3.2mm/2.2mm)
Polyurethane
Lead Length: 39.4” (1M)
IP Rating:
67
REFER TO THE TPI WEBSITE FOR ADDITIONAL OR OEM PROBE OPTIONS
6
Copyright © 2008 Test Products International, Inc.
www.tpi-thevalueleader.com • 503.520.9197
T-Type Thermocouple with Lumberg Connector Probes
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Stem Length: 4”(101.6mm)
Weiner probe
for food
processing
FT12L
Needle probe
-148° to 500°F
-100° to 250°C
Diameter:
0.13”(3.2mm)
PVC
Teflon
PVC
22
22
21
22
28
21
42
48
Lead Length: 39.4” (1.0M)
IP Rating: 67
Stem Length: 3.15”(80mm)
Diameter: 0.06”(1.6mm)
Lead Length: 39.4” (1.2M)
IP Rating: N/A
Stem Length: 3.75”(95.3mm)
Diameter: 3.2/1.6mm
Lead Length: 39.4” (1.0M)
IP Rating: 67
Stem Length: 3.93”(100mm)
Diameter: 0.13” (3.2mm)
Lead Length: 98.4” (2.5M)
IP Rating: N/A
Weiner probe
for food pro-
cessing
FT15L
Needle probe
-148° to 500°F
-100° to 250°C
FT21L
Food
penetration
-148° to 500°F
-100° to 250°C
Tapered end for
food penetration
Waterproof
Testing food
temperature
during cooking
FT22L
Oven food probe
-40° to 500°F
-50° to 250°C
Teflon
Teflon
Polyurethane
Teflon
SS
Stem Length: NA
Diameter: NA
Lead Length: 177.2” (4.5M)
IP Rating: N/A
Testing food
temperature
during cooking
FT23L
Oven food probe
-40° to 950°F
-40° to 510°C
FT24L
General purpose
Stem Length: 24" (610mm)
-40° to 500°F
-40° to 250°C
Heavy duty T-handle penetration into
long stem penetra- semi-solids and
Diameter:
0.37"/0.15" (9.5mm/3.76mm)
Lead Length: 39.4" (1M)
tion probe
liquids
IP Rating:
67
GT13L
Beaded probe
with FDA approved
insulation
Stem Length: NA
Diameter: NA
Lead Length: 47.2” (1.2M)
IP Rating: 67
General
-148° to 500°F
Purpose. Air -100° to 250°C
Stem Length: NA
Diameter: NA
Special
GT19L
Oven clamp probe
-40° to 500°F
hangingClip for
-40° to 510°C
ovens. Air.
Lead Length: 39.4” (1M)
IP Rating:
67
Thermistor Probe with Lumberg Connectors
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Stem Length: 4”(102mm)
Diameter: 0.13” (3.2mm)
FX11L
Liquid immersion
probe
General
-40° to 300°F
PVC
24
Lead Length: 39.4” (1M)
Purpose, Liquid -40° to 150°C
IP Rating:
67
Thermistor Probe with Bipolar Connectors
Model #
Probe
tip
Insulation
Material
Application
Range°F°C
Dimensions
Description
Stem Length: 3.15”(80mm)
Diameter: 0.3” (7.5mm)
Lead Length: 15.7” (0.4M)
IP Rating: N/A
Stem Length: 3.15”(80mm)
Diameter: 0.13” (3.2mm)
Lead Length: 15.7” (0.4M)
IP Rating: N/A
Stem Length: 8”(203mm)
Diameter: 0.13” (3.2mm)
Lead Length: 15.7” (0.4M)
IP Rating: 67
Stem Length: 3.15”(80mm)
Diameter: 0.13” (3.2mm)
Lead Length: 15.7” (0.4M)
IP Rating: N/A
CX13B
Surface flat disk
probe
-40° to 300°F
-40° to 150°C
Surface
30
24
24
44
NA
PVC
PVC
PVC
PVC
PVC
FX12B
-40° to 300°F
-40° to 150°C
Liquid immersion General Purpose
probe
FX13B
-40° to 300°F
-40° to 150°C
Liquid immersion General Purpose
probe
GX15B
Air
-40° to 300°F
-40° to 150°C
Shielded air probe
Stem Length: N/A
Diameter: N/A
Lead Length: 36” (0.9M)
IP Rating: N/A
EX11B
extension lead
Thermistor
probes
N/A
REFER TO THE TPI WEBSITE FOR ADDITIONAL OR OEM PROBE OPTIONS
Copyright © 2008 Test Products International, Inc.
7
The Value Leader
• Digital Multimeters
• Digital Clamp-Ons
Probe selection
TPI has three basic types of temperature probes: Penetration/Immersion (F),
Contact/Surface (C), and Air/Gas (G).
• Temperature Products
• Combustion Analyzers
•
•
•
Penetration/Immersion (F) probes are used for liquids, semi-solids, and solids.
Contact/Surface (C) probes are designed for surface temperatures.
Air/Gas (G) probes are designed to measure air or gas temperatures.
• Carbon Monoxide
Analyzers
Select your type of application and probe tip first. Then match the connector type of the
probe to your instrument.
• Combustible Gas
Detectors
• Digital Manometers
• Indoor Air Quality
OEM/specialty temperature probes
Whatever your OEM temperature probe needs are, let TPI help you. Just let us have the
following information, along with your company and contact information.
• Insulation Resistance
Testers (IRT)
1. Application, environment, and operating temperature
2. New or existing product
3. Annual usage and release quantities
4. Connector type or bare wire details
5. Length of lead wire and straight or coiled wire
6. Probe tip type and dimensions
• Handheld Oscilliscopes
• Refrigeration Leak
Detectors
• Coax / BNC Cables and
Adapters
• Oscilliscope Probes /
SMTP Clips
7. Any other special requirements, materials, etc.
• Specialty Testers
Cost of ownership temperature probe
Ask us about a customized cost of ownership temperature probe program.
Three Year Limited Warranty on TPI Products
Copyright © 2008 Test Products International, Inc.
Temperature Probe brochures 07.10.08
Test Products International, Inc.
Headquarters:
9615 SW Allen Blvd.
Beaverton, OR 97005 USA
503-520-9197
Test Products International, Ltd.
342 Bronte St. South Unit #9
Milton, Ontario L9T 5B7 Canada
905-693-8558
Fax: 905-693-0888
info@tpicanada.com
Test Products International UK Ltd.
Longley House, East Park
Crawley, West Sussex RH10 6AP
England
Tel: +44 (0)1293 561212
Fax: +44 (0)1293 813465
e-mail: info@tpi-uk.com
The
Value
™
Leader
Fax: 503-520-1225
info@tpi-thevalueleader.com
For additional products, specifications, and info contact TPI at tpi-thevalueleader.com or 800.368.5719
相关型号:
GX160VH33130X35LL
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 160V, 330uF, THROUGH HOLE MOUNT, RADIAL LEADED
CHEMI-CON
GX16T101T10X20TP43
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 100uF, THROUGH HOLE MOUNT, AXIAL LEADED
CHEMI-CON
GX16T470T8X16TP
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 47uF, THROUGH HOLE MOUNT, AXIAL LEADED
CHEMI-CON
GX16T470T8X16TP22
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 47uF, THROUGH HOLE MOUNT, AXIAL LEADED
CHEMI-CON
GX16T470T8X16TP32
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 47uF, THROUGH HOLE MOUNT, AXIAL LEADED
CHEMI-CON
GX16T470T8X16TP42
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 47uF, THROUGH HOLE MOUNT, AXIAL LEADED
CHEMI-CON
GX16VB221T12.5X20.5
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 220uF, THROUGH HOLE MOUNT, RADIAL LEADED
CHEMI-CON
GX16VB221T12.5X20.5MT
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 220uF, THROUGH HOLE MOUNT, RADIAL LEADED
CHEMI-CON
GX16VB221T12.5X20.5PT
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 220uF, THROUGH HOLE MOUNT, RADIAL LEADED
CHEMI-CON
GX16VH82235X30LL
CAPACITOR, ALUMINUM ELECTROLYTIC, NON SOLID, POLARIZED, 16V, 8200uF, THROUGH HOLE MOUNT, RADIAL LEADED
CHEMI-CON
©2020 ICPDF网 联系我们和版权申明