Series 1 - 110/125A  
120/240, 480 Vac • AC Output  
Featuring state-of-the-art Surface  
• Zero Voltage and Random  
Turn-On Switching  
Mount Technology, these SPST-NO  
relays deliver proven reliability in the  
most demanding applications.  
Output consists of an SCR AC switch  
and is available in zero-cross, random  
turn-on (phase controllable) and ver-  
sions with either AC or DC input (coil)  
control.  
• Panel Mount  
• Internal Snubber  
Manufactured in Crydom’s ISO 9002  
Certified facility for optimum product  
performance and reliability.  
AC CONTROL  
DC CONTROL  
A24110  
D24110  
A24125  
D24125  
HA48110  
HD48110  
HA48125  
HD48125  
MODEL NUMBERS  
OUTPUT SPECIFICATIONS  
Operating Voltage (47-63 Hz) [Vrms]  
Max. Load Current [Arms]  
Min. Load Current, [mArms]  
24-280  
110  
24-280  
125  
48-530  
110  
48-530  
125  
150  
150  
150  
150  
Transient Overvoltage [Vpk]  
600  
600  
1200  
1500  
1.7  
1200  
1750  
1.7  
Max. Surge Current, (16.6ms) [Apk]  
1500  
1.7  
1750  
1.7  
Max. On-State Voltage Drop @ Rated Current [Vpk]  
Thermal Resistance Junction to Case (R ) [˚C/W]  
.25  
.22  
.25  
.22  
θJC  
2
2
Maximum I t for Fusing, (8.3 msec.) [A sec]  
Max. Off-State Leakage Current @ Rated Voltage [mArms]  
Min. Off-State dv/dt @ Max. Rated Voltage [V/µsec]➁  
Max. Turn-On Time ➃  
9,340  
10  
12,700  
10  
9,340  
10  
12,700  
10  
500  
500  
500  
500  
1/2 Cycle (DC Control), 10.0 msec (AC Control)  
1/2 Cycle (DC Control), 40.0 msec (AC Control)  
Max. Turn-Off Time  
Power Factor (Min.) with Max. Load  
0.5  
0.5  
0.5  
0.5  
INPUT SPECIFICATIONS ➀  
DC CONTROL  
AC CONTROL  
AC CONTROL  
( D P R E F I X )  
( A P R E F I X )  
( E S U F F I X )  
Control Voltage Range  
Max. Reverse Voltage  
Max. Turn-On Voltage  
Min. Turn-Off Voltage  
Nominal Input Impedance  
Typical Input Current  
3-32 Vdc  
-32 Vdc  
90-280 Vrms (60Hz)  
---  
18-36 Vrms  
---  
3.0 Vdc  
90 Vrms  
18 Vrms  
1.0 Vdc  
10 Vrms  
4.0 Vrms  
1500 Ohms (120/240V Models) ➄  
3.4mA @ 5 Vdc, 20mA @ 28Vdc➄  
60K Ohms  
9.0K Ohms  
3mA @ 24 Vrms  
2mA @ 120 Vrms, 4mA @ 240 Vrms  
©1998 CRYDOM CORP, Specifications subject to change without notice.  
GENERAL NOTES  
All parameters at 25ºC unless otherwise specified.  
Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1  
Heat sinking required, for derating curves see page 2.  
Turn-on time for random turn-on versions is 0.02 msec (DC Control Models).  
Input circuitry for 480V models incorporates active current limiter with 2mA typical input current..  
For recommended applications and more information contact:  
USA: (800) 8 CRYDOM (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280  
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com  
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191  
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,  
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU  
GERMANY: (49)871 935405 fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany  
FastFax Document No. 152  
110/125.040898, PAGE 1 OF 2  
Series 1 - 110/125A  
120/240, 480 Vac • AC Output  
GENERAL SPECIFICATIONS  
Dielectric Strength 50/60Hz Input/Output/Base  
Insulation Resistance (Min.) @ 500 Vdc  
Max. Capacitance Input/Output  
4000 Vrms  
109 Ohm  
8 pF  
Ambient Operating Temperature Range  
Ambient Storage Temperature Range  
-40 to 80ºC  
-40 to 125ºC  
MECHANICAL SPECIFICATIONS  
Weight: (typical)  
3.0 oz. (86.5g)  
Encapsulation:  
Terminals:  
Thermally Conductive Epoxy  
Screws and Saddle Clamps Furnished, Unmounted  
AVAILABLE OPTIONS  
24 Vac Input (18-36 Vac)  
1.10  
(27.9)  
MOUNTING  
HOLE/SLOT  
0.17 (4.3) DIA.  
E
8-32 TERMINAL  
(2 PLACES )  
.45  
(11.4)  
Example: A24110E  
Screw Torque Requirements:  
6-32 Screws - 10 in./lbs.,  
8-32 and 10-32 Screws - 20in./lbs.  
-10 Random Turn-On (AC & DC Control)  
Phase Controllable (DC Control)  
Example: D24110-10  
OUTPUT  
2.30  
1
2
(Screws dry without grease.)  
(58.4)  
1.87  
(47.5)  
SOLID-STATE RELAY  
1.70  
(43.2)  
--  
+
4
3
INPUT  
All dimensions are in inches (millimeters)  
Crydom Heat Sinks offer excellent  
thermal management and are per-  
fectly matched to the load current  
ratings of Crydom panel mount  
relays. Request Crydom’s Heat Sink  
specification sheet for all the details.  
1.00  
.78  
BASE PLATE  
.125 (3.2)  
(25.4)  
6-32 TERMINAL  
(2 PLACES)  
(19.8)  
.90  
(22.9)  
1.80  
(45.7)  
CURRENT DERATING CURVES  
110A  
125A  
160  
120  
80  
160  
90  
90  
.4ºC/W  
.4ºC/W  
.2ºC/W  
120  
.2ºC/W  
.5ºC/W  
.5ºC/W  
100  
100  
110  
120  
80  
1ºC/W  
1ºC/W  
110  
120  
40  
0
40  
0
30 60 90 120  
Load Current [Arms]  
0
20 40 60 80  
Max Ambient Temp. [ºC]  
30 60 90 120  
Load Current [Arms]  
0
20 40 60 80  
Max Ambient Temp. [ºC]  
©1998 CRYDOM CORP, Specifications subject to change without notice.  
For recommended applications and more information contact:  
APPROVALS  
USA: (800) 8 CRYDOM (800) 827-9366 • (619) 715-7200 • fax (619) 715-7280  
Crydom Corp, 9525 Chesapeake Drive, San Diego, CA 92123 • e-mail: sales@crydom.com  
WEB SITE: http://www.crydom.com FASTFAX Product Information: (888) 267-9191  
UK: (44)1202 812300 fax (44)1202 812340 Crydom International Ltd., 85, Condor Close,  
Woolsbridge Industrial Estate, Three-Legged Cross. Wimborne, Dorset, England BH21 6SU  
GERMANY: (49)871 935405 fax (49)871 935407, Aussere Parkstr.5, D-84032 Altdorf, Germany  
UL  
E116950  
FastFax Document No. 152  
110/125.040898, PAGE 2 OF 2  

相关型号:

HA48110EF-B

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EGH

Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4
CRYDOM

HA48110EGH-10

Trigger Output SSR, 1-Channel, 4000V Isolation, ROHS COMPLIANT, PLASTIC PACKAGE-4
CRYDOM

HA48110EGH-B

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EGP

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EGP-10

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EGP-B

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EGPH-10

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EGPH-B

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EGT-10

Trigger Output SSR,
CRYDOM

HA48110EH-B

Trigger Output SSR, 1-Channel, 4000V Isolation, PLASTIC PACKAGE-4
CRYDOM

HA48110EHT-10

Trigger Output SSR, 1-Channel, 4000V Isolation,
CRYDOM