FEATURES  
HUMMER MODULE  
40 OR 70 WATTS  
H
OLD  
28 VOLT  
U
P
M
ODULE  
NPUT  
• –55°C to +125°C  
• 12 to 40 VDC input  
• Sync on HUM-70  
• Reduce hold-up  
capacitance by 80%  
• Powers DC/DC converters  
with 28 Vin nominal  
• Hold-up time  
I
MODELS  
POWER OUTPUT  
HUM-40  
40 watts  
HUM-70  
70watts  
HUM-40 15 µs/µF  
HUM-70 8.6 µs/µF  
• Low power flag  
• Inhibit function  
Size (max.): HUM-40, non flanged, Case F2  
1.950 x 1.350 x 0.415 inches (49.53 x 34.29 x 10.54 mm)  
HUM-40, flanged, Case J2  
2.720 x 1.350 x 0.415 inches (69.09 x 34.29 x 10.54 mm)  
HUM-70 Case U1  
1.505 x 3.005 x 0.400 inches (38.23 x 76.33 x 10.16 mm)  
See Section B8, cases F2, J2, and U1, for dimensions.  
HUM-40 50 grams max. (flanged 60 grams typical)  
HUM-70 70 grams max.  
Weight:  
Screening: Standard or ES. See Section C2 for screening option and Section A5  
for ordering information.  
DESCRIPTION  
Interpoint’s HUMMER™ Hold-Up Module Series provides a single  
product solution to the problem of maintaining electronic system  
operation during input power drop-out, typically reducing bulk  
capacitance requirements by more than 80%. The HUMMER  
module is compatible with the Interpoint DC/DC converters in  
Section B1 that have a 28 VDC nominal input and a high input line  
of 40 VDC.  
GENERAL OPERATION  
The HUMMER module and two external components (a hold-up  
capacitor and a diode) are connected between the line source and  
the DC/DC converter as shown in Figure 3 (HUMMER Module  
System Block Diagram.) If an EMI filter is employed, the HUMMER  
module is connected between the filter and the converter). The  
module first charges the external capacitor to 40 volts, and then  
allows the converter to operate off the line voltage. When the line  
voltage drops to between 12 to 18 VDC, a boost converter in the  
module supplies an output at the capacitor charging voltage (40  
VDC). If power fails (the input voltage drops below 12 VDC), the  
converter is powered from the external hold-up capacitor.  
The traditional procedure for providing hold-up during power loss is  
to buffer the device with enough bulk capacitance to allow a  
controlled shutdown to occur or an alternative power source to be  
brought on line. The problem with this approach is that very large  
capacitor banks are required because the capacitors are charged at  
the relatively low voltage at which power fails.  
The HUMMER Hold-Up Module provides an alternative with two  
important advantages: 1) it effectively reduces the low line voltage  
for normal DC/DC converter operation to 12 VDC thereby reducing  
power drop-out events, and 2) it charges hold-up capacitors to 40  
volts, reducing the capacitance needed to produce a given hold-up  
time.  
B6-3  
HUMMER SERIES  
40 OR 70 WATTS  
HOLD  
UP  
M
ODULE  
ABSOLUTE MAXIMUM RATINGS  
SYNC AND INHIBIT  
Sync (HUM-70 only)  
Output Power  
• Range 525 min to 625 max kHz  
• Duty cycle 40% min to 60% max  
• Logic low 0.8V, max  
• HUM-40 40 watts  
* HUM-70 70 watts  
Input Voltage Range  
• 12 to 50 continuous  
• 80 V for up to 50 ms  
Lead Soldering Temperature (10 sec per lead)  
• 300°C  
Storage Temperature Range (Case)  
• –65°C to +135°C  
• Logic high 4.5 V, min  
• Referenced to input common  
• If sync is not used, leave unconnected  
Inhibit TTL Open Collector  
• Logic low (output disabled)  
Logic low voltage 0.8 V max  
Inhibit pin current 15 mA  
• Referenced to input common  
• Logic high (output enabled)  
Open circuit voltage 10 V typical  
RECOMMENDED OPERATING CONDITIONS  
Input Voltage Range  
• 12 to 40 VDC continuous  
Case Operating Temperature (Tc)  
• –55 to +125°C full power  
Electrical Characteristics: 25°C Tc, 28 VDC Vin, 100% load, free run, unless otherwise specified.  
HUM-40  
MIN  
HUM-70  
PARAMETER  
OUTPUT VOLTAGE  
OUTPUT POWER  
CONDITION  
CEXT TERMINAL  
CONTINUOUS  
PEAK, 2 SEC  
MAX  
40  
MIN  
MAX  
40  
UNITS  
39  
12  
39  
12  
VDC  
40  
70  
W
60  
100  
50  
INPUT VOLTAGE  
CONTINUOUS  
TRANSIENT 50 ms  
2 MHz Bandwidth  
50  
VDC  
V
80  
80  
INPUT RIPPLE CURRENT  
INPUT CURRENT  
100  
90  
100  
90  
mA p-p  
V
= 28V, VCS OPEN  
IN  
mA  
A
V
= 28V, INHIBITED  
= 12V, FULL LOAD  
= 40V, FULL LOAD  
= 22V, FULL LOAD  
= 12V, FULL LOAD  
FULL LOAD  
10  
10  
IN  
V
92  
87  
80  
4.6  
92  
87  
80  
8.6  
IN  
V
V
V
IN  
IN  
IN  
EFFICIENCY  
%
HOLD-UP TIME  
15  
14.0  
11.5  
22  
14.5  
12.0  
24  
8.6  
14.0  
11.5  
22  
14.5  
12.0  
24  
µs/µF  
VDC  
POWER FAIL  
HIGH, OPEN CIRCUIT  
LOW, SHORT RETURN  
OPEN  
FLAG THRESHOLD  
CAPACITOR VOLTAGE  
CONTROLLED SWITCH  
CAP CHARGED  
VDC  
VDC  
CLOSED  
18  
19  
18  
19  
HIGH, OPEN CIRCUIT  
LOW, SHORT RETURN  
34  
36  
34  
36  
FLAG THRESHOLD  
19.5  
20.5  
19.5  
20.5  
Notes  
1. Full load for specifications is 40 W for HUM-40 and 70 W for HUM-70.  
B6-4  
HUMMER SERIES  
40 OR 70 WATT  
HOLD  
UP  
M
ODULE  
PIN OUT  
Pin  
HUM-40 (40 Watt)  
No connection  
HUM-70 (70 Watt)  
1
2
Sync  
VCS (Voltage Control Switch)  
+ CEXT (Ext. Capacitor, Positive)  
CEXT Return (Ext. Capacitor, Return)  
Input Common  
Cap Charged Flag  
Inhibit  
3
4
Power Fail Flag  
No connection  
No connection  
VCS (Voltage Control Switch)  
5
6
Positive Input  
7
Case Ground  
8
Cap Charged Flag  
Inhibit  
+ CEXT (Ext. Capacitor, Positive)  
CEXT Return (Ext. Capacitor, Return)  
Input Common  
9
10  
11  
12  
Power Fail Flag  
N/A  
Positive Input  
N/A  
No connection  
Angled corner indicates pin one.  
Dot on top of cover indicates pin one.  
1
12  
11  
10  
9
1
2
3
4
5
6
BOTTOM VIEW  
HUM-40  
2
TOP VIEW  
HUM-70  
(Pin side, marked side)  
See Section B8, case U1, for dimensions.  
FLANGED AND NON-FLANGED  
See Section B8, cases F2,  
3
4
5
6
and J2, for dimensions.  
10  
9
8
7
8
7
Dotted line outlines flanged package option.  
FIGURE 1: HUM-40 PIN OUT  
FIGURE 2: HUM-70 PIN OUT  
MODEL NUMBERING KEY  
HUM - 40  
Base Model  
F
/
ES  
HUM - 70 / ES  
Base Model  
Output Power  
Screening  
Output Power  
Case Option  
(Non-flanged case has no designator in  
this position)  
(Standard screening has no designator  
in this position.)  
Screening  
(Standard screening has no designator  
in this position.)  
B6-5  
HUMMER SERIES  
40 OR 70 WATT  
HOLD  
UP  
MODULE  
DC-DC  
CONVERTER  
LOAD  
28 VDC  
HUMMER  
HOLD-UP  
MODULE  
+VIN  
+VIN  
VCS  
+VOUT  
EMI  
CAPACITOR  
CHARGED  
FILTER  
INHIBIT  
VOUT  
(IF USED)  
VIN  
RETURN  
RETURN  
+CEXT  
28 VDC  
RETURN  
1
CEXT  
CEXT  
RETURN  
CASE  
GROUND  
VIN RETURN  
1. EXTERNAL HOLDUP  
CAPACITOR  
POWER INHIBIT  
FAIL  
FIGURE 3: HUMMER MODULE SYSTEM BLOCK DIAGRAM  
Note: The HUMMER module is rated at a total operating power  
more than its output rating in order to allow it to both deliver a  
full load and to continue charging the external capacitor (the  
HUM-40, for example, is rated at 40 W output and 60 W total  
operating power, allowing it to deliver 40 W to a load and charge  
a capacitor at 10 to 20 J/sec). However, if the input voltage  
ramps up slowly into a full converter load, the total power drawn  
at low voltage could send the module into current limit which  
would shut the unit down.  
DETAILED OPERATIONAL DESCRIPTION  
The detailed operation of the HUMMER module is divided into 4  
operations: Initialization and Charging, Normal Operation, Low  
Line Operation, and Power Fail Operation. For details, refer to the  
following text, Figure 4 (HUMMER Module Block Diagram) and  
Figure 5 (HUMMER Module Signal Diagram).  
1. INITIALIZATION AND CHARGING  
As the input voltage ramps up to 8 to 10 volts, the internal  
HUMMER module circuits are biased to provide correct output  
states on all flags. As the input reaches 14 VDC, the Power Fail  
flag (active low) is released, the voltage control switch (VCS) is  
closed, and the module begins operating in a boost mode to  
charge the external capacitor to 40 volts. At this point, if the recom-  
mended connection has been made between the Capacitor  
Charged pin and the inhibit pin of the converter as shown in Figure  
3, all of the module energy is dedicated to charging the capacitor  
and the converter will be inhibited until the capacitor charge  
reaches 36 V. If this connection has not been made, the energy  
available to charge the capacitor will be the difference between the  
current required by the converter’s load and the current capacity of  
the HUMMER module.  
When the input voltage reaches approximately 22 VDC, the VCS  
is opened, isolating the stored charge on the external capacitor  
and allowing the converter to operate directly from the input power  
bus via the external system diode (unless the converter is still  
inhibited by the connection between the Capacitor Charged pin  
and converter’s inhibit pin) while the capacitor continues to charge.  
When the charge on the external capacitor reaches approximately  
35 volts (80% of a full charge), the Capacitor Charged flag will be  
asserted (removing the inhibit from the converter if applicable) and  
the HUMMER module will be in normal operation.  
VCS  
INPUT  
+CEXT  
+VIN  
CURRENT  
LIMIT  
+
PWM  
+
+
CEXT  
RETURN  
VIN  
RETURN  
CURRENT  
SENSE  
CASE  
GROUND  
POWER  
FAIL  
INHIBIT CAPACITOR  
CHARGED  
FIGURE 4: HUMMER MODULE BLOCK DIAGRAM  
B6-6  
HUMMER SERIES  
40 OR 70 WATTS  
H
OLD  
UP  
M
ODULE  
2. NORMAL OPERATION  
3. LOW LINE OPERATION  
Normal operation continues with the capacitor charged and the  
input line voltage between 18 and 40 VDC. During this time, the  
converter will operate from the line voltage through the external  
diode. When the external capacitor reaches its final charge of 40  
volts, the HUMMER module enters an idle state, consuming only  
enough power to keep the capacitor charged. Idle state power for  
the module is approximately 1 watt.  
Low line operation occurs when the input voltage drops to a range  
between 18 and 12 volts. When the voltage reaches 18 VDC, the  
HUMMER module’s VCS closes and then operates in a boost  
mode. In this mode, the HUMMER module supplies 40 VDC  
through VCS to the converter, and at the same time maintains the  
charge on the capacitor. The module will operate indefinitely in this  
low line region until the input line voltage drops below 12 VDC.  
Note: The HUMMER module itself can sustain continuous voltages  
of up to 50 VDC and voltage spikes of 80 volts for up to 50  
msec, and it will pass these voltages on to the converter through  
the external bypass diode. If these ratings exceed the rating of  
the converter, care should be taken to control the line voltage to  
prevent damage to the converter.  
4. POWER FAIL OPERATION  
When the input line voltage drops to 12 VDC, the Power Fail flag  
is asserted (pulled low) and the HUMMER module’s boost mode is  
disabled. At this point, the converter load is powered by the stored  
energy in the external capacitor. When the voltage on the external  
capacitor falls to 20 VDC, the Capacitor Charged flag is released  
(pulled low), indicating that 90% of the usable stored energy has  
been depleted. If the connection has been made between the  
Capacitor Charged pin and the converter’s Inhibit pin, the  
converter will also be inhibited.  
Normal Operation will continue indefinitely until the input voltage  
drops below 18 VDC.  
30 –  
VIN = 22  
VIN = 23  
VIN = 19—  
VIN = 19—  
20 –  
10 –  
0 –  
VIN  
VIN = 14  
VIN = 10  
VIN = 12  
VCAP  
VIN  
VCAP  
40 –  
30 –  
20 –  
10 –  
0 –  
VIN  
VCS  
WITH  
DIODE  
VCS  
CLOSED  
VCS  
CLOSED  
RAMP  
DOWN ON  
EXT CAP  
VCAP = 40  
VCAP = 20—  
40 –  
30 –  
20 –  
10 –  
0 –  
VCAP = 35—  
EXT  
CAP  
OPEN  
POWER  
FAIL  
0 –  
CAP  
CHARGED  
0 –  
INITIALIZATION &  
CHARGING  
NORMAL  
LOW  
NORMAL  
OPERATION  
POWER FAIL  
OPERATION  
OPERATION LINE  
OPERATION  
FIGURE 5: HUMMER MODULE SIGNAL DIAGRAM  
B6-7  
HUMMER SERIES  
40 OR 70 WATT  
HOLD  
UP  
M
ODULE  
PIN CONNECTIONS  
CAUTION: Do not connect the HUMMER module’s input return pin  
to the Cext return. This connection will short the module’s current  
limit sense resistor resulting in excessive currents that can also  
damage the DC/DC converter.  
EXTERNAL CAPACITOR SELECTION  
The external capacitor supplies the energy for the DC/DC  
converter’s operation during power failure. Interpoint recommends  
CLR-79 or CLR-81 wet slug tantalum capacitors because of their  
high CV properties and extended temperature operation. An alter-  
native choice is a high quality grade aluminum electrolytic. To  
ensure maximum system stability, the capacitors should have a  
minimum ESR of 0.25 ohms, a minimum capacitance of 330 uF, and  
a maximum capacitance of 1 F.  
INHIBIT FUNCTION  
The HUMMER module’s inhibit pin disables the internal boost  
converter when the Inhibit pin is pulled low. This is accomplished by  
an external connection to the Vin Return pin or Vout Return pin. The  
inhibit open circuit voltage is is 10 V and the short circuit current is  
15 mA. It is open-collector TTL or CMOS compatible. The pin is  
diode-isolated and can be reverse biased to include the input poten-  
tial. Power Fail and Capacitor Charged flags are operable when the  
unit is inhibited.  
The capacitance needed and derating required will depend on the  
system requirements, the load, and the efficiency of the converter  
being supplied power. The amount of capacitance for a given hold-  
up time is determined by the formula  
FLAG FUNCTIONS  
2Pt  
where  
C =  
:
POWER FAIL FLAG  
2
2
)
n (V  
V  
1
2
The Power Fail Flag output is implemented by a comparator moni-  
toring the input voltage. (The comparator is also used to inhibit  
HUMMER module’s operation; note however, that the flag is func-  
tional when the unit is inhibited.) The input voltage threshold is  
nominally 14.5 V to indicate that sufficient voltage is present for  
operation. The comparator output drives an internal MOSFET buffer  
which connects to the external Power Fail pin. The buffer is of an  
open drain configuration and requires an external pull-up resistor  
and voltage for indication. The maximum recommended pull-up  
voltage is 36 V. The maximum short circuit should not exceed 10mA.  
The buffer is protected by a shunt zener diode connected between  
the drain and the Cext Return. In normal operation, the input voltage  
exceeds the 14 V threshold and the output is high (open drain).  
When the input voltage is below 12 V the output is low, and the  
MOSFET conducts to the Return.  
C is required capacitance (in Farads).  
P is power to the load (output of converter) to be held up (in watts)  
n is the efficiency of the converter at rated load (in %)  
tis required hold-up time (in seconds)  
V1is charged capacitor voltage (in volts)  
V2is low-line voltage of DC/DC converter (in volts)  
For a 50 msec hold-up of 30 W output from a converter with a effi-  
ciency of 80% and a 16 VDC low line and a 40 V capacitor charge:  
(2) • (30) • (0.050)  
3
C =  
C =  
= 2790 µF  
;
2
2
(0.80) • (40 – 16 )  
1075.2  
CAPACITOR CHARGED FLAG  
A Capacitor Charged Flag is implemented by a comparator moni-  
toring the HUMMER module’s +Cext terminal. The capacitor voltage  
threshold is 36 V, at which point the external capacitor is charged to  
80% of its maximum value. When the capacitor discharges, the flag  
resets at 20 VDC indicating that approximately 10% of the charge  
remains. The comparator output drives a MOSFET buffer amplifier,  
and the buffer output connects to the Cap Charged pin. The buffer  
is of an open drain configuration and requires a pull-up resistor and  
voltage for indication. The maximum recommended pull-up voltage  
is 36 V. The maximum short circuit current should not exceed 10  
mA. During normal operation, the input is 40 V, exceeding the  
threshold, and the output is high (open circuit). When the capacitor  
voltage is below 20 V, the output is low, and the MOSFET conducts  
to the Return. The HUMMER module must be supplied with a  
minimum of 8 VDC for biasing internal circuits to obtain correct  
output states.  
Note: The output power delivered by the HUMMER module to  
deliver 30 W to the load with an 80% efficient converter is 37.5  
watts. The HUM-40 is rated to deliver a maximum of 40 watts to  
the input of the converter. Interpoint data sheets for individual  
converters supply an efficiency curve vs. line and load for each  
converter model. In calculations, assume the efficiency rating for  
the nominal (usually 28 V) line condition.  
Note: If the Capacitor Charged pin is connected to the converter’s  
inhibit pin as shown in Figure 3, use 20 V as the low line figure in  
the formula.  
DIODE SELECTION AND CONNECTION  
An external diode is required for system operation as shown in  
Figure 3, with the diode anode connected to the HUMMER module’s  
VCS pin and the DC/DC converter’s +V in pin. This diode supplies  
input voltage to the converter when the internal voltage control  
switch (VCS) is open. The diode should be selected with a minimum  
current rating of 5 A and a voltage breakdown rating of 50 V or  
greater (similar to Motorola MDR1060 or equivalent).  
26821-001-DTS Rev A  
DQ# 3002  
All technical information is believed to be accurate, but no responsibility is  
assumed for errors or omissions. Interpoint reserves the right to make changes in  
products or specifications without notice. HUMMER is a trademark of Interpoint.  
Copyright © 1994 - 1999 Interpoint. All rights reserved.  
B6-8  
CASE F  
CASES  
Dot on top of case indicates pin one  
Materials  
Header Case F1  
Cold Rolled Steel/Nickel/Gold  
Cases F2 - F4  
Cold Rolled Steel/Nickel/Tin  
Cover Case F1  
CASE F  
BOTTOM VIEW  
See Figures 20 - 23 for pin configuration  
1.350 max  
(34.29)  
Kovar/Nickel  
Cases F2 - F4  
Cold Rolled Steel/Nickel/Tin  
Pins  
#52 alloy (all cases)  
MHV Series Triple – compression glass seal  
MTR Series Triple, case F1 – ceramic seal  
MTR Series Triple, case F2 – compression glass seal  
HUM40 – compression glass seal or ceramic seal  
Case F3 – compression glass seal  
Case F4 – compression glass seal or ceramic seal  
1.950 max  
(49.53)  
CAUTION  
Heat from reflow or wave soldering may damage  
the device. Solder pins individually with heat  
application not exceeding 300°C for 10 seconds  
per pin.  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.2) for two decimal places  
unless otherwise specified  
FIGURE 19: CASE F MAXIMUM DIMENSIONS  
BOTTOM VIEW CASE F1  
MTR Series Triple and MHV Series Triple: Screening – Standard, ES, or 883  
Platform  
Bathtub  
Dot on top of case indicates pin one  
Seam Seal  
1.170  
(29.72)  
1
2
9
3
8
4
7
5
6
0.040 dia.  
(1.02)  
MTR  
MHV  
Series  
Series  
10  
0.170  
(4.32)  
0.000  
FIGURE 20: CASE F1  
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer  
to the numerical dimensions for accuracy.  
B8-12  
CASE F  
CASES  
BOTTOM VIEW CASE F2  
HUM-40: Screening – Standard or ES  
Squared corner and dot on top  
of case indicate pin one.  
Solder Seal  
1.170  
(29.72)  
1
2
9
3
8
4
5
6
0.040 dia.  
(1.02)  
Solder Tip-off  
10  
7
0.170  
(4.32)  
0.000  
FIGURE 21: CASE F2  
BOTTOM VIEW CASE F3  
MRH Series: Screening – Standard or ES  
Squared corner and dot on top  
of case indicate pin one.  
Solder Seal  
1.170  
(29.72)  
1
2
9
3
8
4
5
6
0.040 dia.  
(1.02)  
Solder Tip-off  
10  
7
0.170  
(4.32)  
0.000  
FIGURE 22: CASE F3  
B8-13  
CASE J  
CASES  
Dot on top of case indicates pin one  
CASE J  
BOTTOM VIEW  
See Figures 36 - 40  
for pin configuration  
1.350 max  
(34.29)  
2.720 max  
(69.09)  
Flange Thickness:  
Cases J1 and J5  
Case J2  
0.060 (1.52)  
0.073 (1.85) max  
Cases J3 and J4  
0.067 +0.005/-0.007 (1.70 +0.13/-0.8)  
Materials  
Header Case J1  
Cold Rolled Steel/Nickel/Gold  
Cases J2 - J5  
Cold Rolled Steel/Nickel/Tin  
Cover Case J1  
Kovar/Nickel  
Case J2 - J5  
Cold Rolled Steel/Nickel/Tin  
#52 alloy (all cases)  
Pins  
Case J1  
MHV Series Triple – compression glass seal  
MTR Series Triple – ceramic seal  
Cases J2 - J5  
compression glass seal  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.2) for two decimal places  
unless otherwise specified  
CAUTION  
Heat from reflow or wave soldering may damage  
the device. Solder pins individually with heat  
application not exceeding 300°C for 10 seconds  
per pin.  
FIGURE 35: CASE J MAXIMUM DIMENSIONS  
Note: Although every effort has been made to render the case drawings at actual size, variations in the printing process may cause some distortion. Please refer  
to the numerical dimensions for accuracy.  
B8-22  
CASE J  
CASES  
BOTTOM VIEW CASE J2  
Flanged case: Designator required in Case Option position of model number.  
HUM-40 Module: Screening – Standard or ES  
Squared corner and dot on top  
Solder Seal  
of case indicate pin one.  
1.173  
(29.79  
1
2
9
3
4
7
5
6
0.040 dia.  
(1.02)  
0.673  
(17.09)  
HUM-40 Module  
8
Solder Tip-off  
10  
0.173  
(4.39)  
0.000  
FIGURE 37: CASE J2  
BOTTOM VIEW CASE J3  
Flanged case: Designator required in Case Option position of model number.  
MRH Series: Screening – Standard or ES  
Squared corner and dot on top  
of case indicate pin one.  
Solder Seal  
1.173  
(29.79  
1
2
9
3
8
4
7
5
6
0.040 dia.  
(1.02)  
0.162 dia  
(4.11)  
0.673  
(17.09)  
Solder Tip-off  
10  
0.173  
(4.39)  
0.000  
FIGURE 38: CASE J3  
B8-24  
CASE U  
CASES  
Angled corner indicates pin one  
CASE U  
TOP VIEW  
(PIN SIDE)  
1.505 max (38.23)  
See Figures 55 and 56 for dimensions  
3.005 (76.33) max.  
Note: Pins are shown for Case U1.  
Materials  
Header Cold Rolled Steel/Nickel/Gold  
Cover Kovar/Nickel  
Pins  
#52 alloy/Gold  
compression glass seal  
Case dimensions in inches (mm)  
Tolerance ±0.005 (0.13) for three decimal places  
±0.01 (0.2) for two decimal places  
unless otherwise specified  
CAUTION  
Heat from reflow or wave soldering may damage  
the device. Solder pins individually with heat  
application not exceeding 300°C for 10 seconds  
per pin.  
FIGURE 54: CASE U MAXIMUM DIMENSIONS  
B8-36  
CASE U  
CASES  
TOP VIEW CASE U1  
MFL Series and MHP Series: Screening – Standard, ES or 883  
MFLHP Series, FMD270 EMI Filter, and FMD28-461SL EMI Filters:  
Screening – Standard or ES  
SMFL, SMFLHP, SMHP, and SSP Series; SFCS, and SFME EMI Filters:  
Screening – Standard, Class H or K  
HUM70 Module and LCM Module: Screening – Standard or ES  
Seam Seal  
Angled corner  
indicates pin one.  
0.23 (5.8) Lead Length  
0.128 dia  
(3.25).  
1.505 (38.23) max.  
1.380 (35.05)  
0.040 dia  
(1.02)  
1.250 (31.75)  
1.050 (26.67)  
0.850 (21.59)  
0.650 (16.51)  
0.450 (11.43)  
0.250 (6.35)  
0.120 (3.05)  
0.000  
FIGURE 55: CASE U1  
B8-37  
QA SCREENING  
125°C PRODUCTS  
125°C PRODUCTS  
TEST (125°C Products)  
STANDARD  
/ES  
/883 (Class H)*  
PRE-CAP INSPECTION  
Method 2017, 2032  
yes  
yes  
yes  
TEMPERATURE CYCLE (10 times)  
Method 1010, Cond. C, -65°C to 150°C  
Method 1010, Cond. B, -55°C to 125°C  
no  
no  
no  
yes  
yes  
no  
CONSTANT ACCELERATION  
Method 2001, 3000 g  
Method 2001, 500 g  
no  
no  
no  
yes  
yes  
no  
BURN-IN  
Method 1015, 160 hours at 125°C  
96 hours at 125°C case (typical)  
no  
no  
no  
yes  
yes  
no  
FINAL ELECTRICAL TEST MIL-PRF-38534, Group A  
Subgroups 1 through 6: -55°C, +25°C, +125°C  
Subgroups 1 and 4: +25°C case  
no  
yes  
no  
yes  
yes  
no  
HERMETICITY TESTING  
Fine Leak, Method 1014, Cond. A  
Gross Leak, Method 1014, Cond. C  
Gross Leak, Dip (1 x 10 )  
no  
no  
yes  
yes  
yes  
no  
yes  
yes  
no  
-3  
FINAL VISUAL INSPECTION  
Method 2009  
yes  
yes  
yes  
Test methods are referenced to MIL-STD-883 as determined by MIL-PRF-38534.  
*883 products are built with element evaluated components and are 100% tested and guaranteed over  
the full military temperature range of –55°C to +125°C.  
Applies to the following products (some models do not offer “883” screening, please refer to the individual  
series datasheets to determine what screening is available):  
MOR Series  
MFLHP Series  
MFL Series  
MHP Series  
MTR Series  
MQO Series  
MHD Series  
MHV Series  
MHF+ Series  
MHF Series  
MGA Series  
MSA Series  
MGH Series  
MCH Series  
FM-704A EMI Filter  
FMD/FME EMI Filter  
FMC EMI Filter  
FMH EMI Filter  
FMGA EMI Filter  
FMSA EMI Filter  
HUM Modules  
LCM Modules  
LIM Modules  
C2-10  

相关型号:

HUM-70J/ES

Analog IC
ETC

HUM-70J2

Analog IC
ETC

HUM-70J2/883

Analog IC
ETC

HUM-70J2/ES

Analog IC
ETC

HUM-70J3

Analog IC
ETC

HUM-70J3/883

Analog IC
ETC

HUM-70J3/ES

Analog IC
ETC

HUM-70U

Analog IC
ETC

HUM-70U/883

Analog IC
ETC

HUM-70U/ES

Analog IC
ETC

HUM-70U1

Analog IC
ETC

HUM-70U1/883

Analog IC
ETC