IL260 IL261  
High Speed Five Channel Digital Couplers  
Functional Diagram  
Features  
3.3 V or 5 V CMOS/TTL Compatible  
110 Mbps Data Rate  
2500 VRMS Isolation (1 min)  
2 ns Typical Pulse Width Distortion  
4 ns Typical Propagation Delay Skew  
10 ns Typical Propagation Delay  
30 kV/ms Typical Transient Immunity  
2 ns Channel to Channel Skew  
0.3'' and 0.15'' 16–Pin SOIC Packages  
Extended Temperature Range (-40°C to +85°C)  
UL1577 Approval Pending  
IEC 61010-1 Approval Pending  
Applications  
ADCs and DACs  
Multiplexed Data Transmission  
Data Interfaces  
Board-To-Board Communication  
Digital Noise Reduction  
Operator Interface  
Ground Loop Elimination  
Peripheral Interfaces  
Parallel Bus  
Logic Level Shifting  
Plasma Displays  
Description  
NVE's family of high-speed digital isolators are CMOS  
devices created by integrating active circuitry and our GMR-  
based and patented* IsoLoop® technology. The IL260 and  
IL261 are five channel versions of the world's fastest digital  
isolator with a 110 Mbps data rate. This device provides the  
designer with the most compact isolated logic devices yet  
available. All transmit and receive channels operate at 110  
Mbps over the full temperature and supply voltage range. The  
symmetric magnetic coupling barrier provides a typical  
propagation delay of only 10 ns and a pulse width distortion  
of 2 ns achieving the best specifications of any isolator device.  
Typical transient immunity of 30 kV/µs is unsurpassed. High  
channel density make them ideally suited to isolating multiple  
ADCs and DACs, parallel buses and peripheral interfaces.  
Performance is specified over the temperature range of -40°C  
to +85°C without any derating. .  
Isoloop® is a registered trademark of NVE Corporation.  
*U.S. Patent number 5,831,426; 6,300,617 and others.  
ISB-DS-001-IL612-A, January 20, 2005  
NVE Corp., 11409 Valley View Road, Eden Prairie, MN 55344-3617, U.S.A.  
Telephone: 952-829-9217, Fax 952-829-9189, www.isoloop.com  
© 2005 NVE Corporation  
IL260 IL261  
Absolute Maximum Ratings  
Parameters  
Symbol  
TS  
Min.  
-55  
Typ.  
Max.  
175  
Units  
Test Conditions  
Storage Temperature  
Ambient Operating Temperature  
Supply Voltage  
°C  
°C  
V
TA  
-55  
125  
V
DD1 ,VDD2  
-0.5  
-0.5  
-0.5  
-10  
7
Input Voltage  
VI  
VO  
IO  
VDD+0.5  
VDD+0.5  
10  
V
V
Output Voltage  
Output Current  
mA  
°C  
Drive Channel  
10 s  
Lead Solder Temperature  
ESD  
280  
2 kV Human Body Model  
Recommended Operating Conditions  
Parameters  
Symbol  
Min.  
-40  
3.0  
4.5  
2.4  
0
Typ.  
Max.  
85  
5.5  
5.5  
VDD  
0.8  
1
Units  
°C  
Test Conditions  
Ambient Operating Temperature(1)  
Supply Voltage  
TA  
V
DD1 ,VDD2  
DD1 ,VDD2  
VIH  
V
3.3/5.0 V Operation  
5 V Operation  
Supply Voltage  
V
V
Logic High Input Voltage  
Logic Low Input Voltage  
Minimum Input Signal Rise and  
Fall Times  
mA  
V
VIL  
tIR, tIF  
µsec  
Insulation Specifications  
Parameters  
Symbol  
Min.  
Typ.  
Max.  
Units  
Test Conditions  
Creepage Distance (external)  
0.15'' SOIC  
4.026  
8.077  
mm  
mm  
µARMS  
|| pC  
0.30'' SOIC  
Leakage Current(5)  
0.2  
240 VRMS  
Barrier Impedance (5)  
>1014||7  
Safety & Approvals  
IEC61010-1  
TUV Certificate Numbers:  
Classification  
Approval Pending  
Max. Working  
Model  
Package  
Pollution Degree  
Material Group  
Voltage  
IL260, IL261  
IL260-3, IL261-3  
II  
II  
III  
III  
300 VRMS  
150 VRMS  
.30'' 16-pin SOIC  
.15'' 16-pin SOIC  
UL 1577  
Component Recognition program. File #:  
Approval Pending  
Rated 2500VRMS for 1 minute (SOIC, PDIP), 1000VRMS for 1 minute (MSOP)  
Electrostatic Discharge Sensitivity  
This product has been tested for electrostatic sensitivity to the limits stated in the specifications. However, NVE recommends that all integrated  
circuits be handled with appropriate care to avoid damage. Damage caused by inappropriate handling or storage could range from performance  
degradation to complete failure.  
2
IL260 IL261  
IL260 Pin Connections  
Input 1  
1
2
IN1  
GND1  
IN2  
Ground Pins 2 and 8 connected internally  
Input 2  
3
Input 3  
4
IN3  
Input 4  
5
IN4  
VDD1  
IN5  
Supply Voltage 1  
6
Input 5  
7
Ground Pins 2 and 8 connected internally  
8
GND1  
GND2  
OUT5  
OUT4  
OUT3  
OUT2  
OUT1  
GND2  
VDD2  
Ground Pins 9 and 15 connected internally  
9
Output 5  
10  
11  
12  
13  
14  
15  
16  
Output 4  
Output 3  
Output 2  
Output 1  
Ground Pins 9 and 15 connected internally  
Supply Voltage 2  
IL260  
*
Pins 2 and 8 internally connected  
** Pins 9 and 15 internally connected  
IL260 Pin Connections  
Supply Voltage 1  
1
2
VDD1  
GND1  
IN1  
Ground Pins 2 and 8 connected internally  
Input 1  
3
Input 2  
4
IN2  
Input 3  
5
IN3  
IN4  
OUT5  
GND1  
GND2  
IN5  
OUT4  
OUT3  
OUT2  
OUT1  
GND2  
VDD2  
Input 4  
6
Output 5  
7
Ground Pins 2 and 8 connected internally  
8
Ground Pins 9 and 15 connected internally  
9
Input 5  
10  
11  
12  
13  
14  
15  
16  
Output 4  
Output 3  
Output 2  
Output 1  
Ground Pins 9 and 15 connected internally  
Supply Voltage 2  
IL261  
*
Pins 2 and 8 internally connected  
** Pins 9 and 15 internally connected  
3
IL260 IL261  
3.3 Volt Electrical Specifications  
Electrical Specifications are Tmin to Tmax  
Parameters  
Symbol  
Min.  
Typ.  
30  
Max.  
50  
Units  
Test Conditions  
Input Quiescent Current  
IL260  
IL261  
IL260  
IL261  
IDD1  
µA  
mA  
mA  
mA  
µA  
V
1.5  
6.5  
5.5  
2.0  
10  
Output Quiescent Current  
IDD2  
8
10  
Logic Input Current  
Logic High Output Voltage  
Ii  
VOH  
-10  
VDD-0.1  
0.8*VDD  
VDD  
VDD-0.5  
0
IO = -20 µA, VI=VIH  
IO = -4 mA, VI=VIH  
IO = 20 µA, VI=VIL  
IO = 4 mA, VI=VIL  
Logic Low Output Voltage  
VOL  
0.1  
0.8  
V
0.5  
Switching Specifications  
Maximum Data Rate  
Minimum Pulse Width  
100  
10  
110  
Mbps  
ns  
ns  
CL = 15 pF  
50% Points, VO  
CL = 15 pF,  
PW  
tPHL  
Propagation Delay Input to Output  
(High to Low)  
12  
18  
18  
Propagation Delay Input to Output  
tPLH  
12  
ns  
CL = 15 pF,  
(Low to High)  
(2)  
Pulse Width Distortion |tPHL-tPLH  
Propagation Delay Skew (3)  
Output Rise Time (10-90%)  
Output Fall Time (10-90%)  
|
PWD  
2
4
3
6
4
4
ns  
ns  
CL = 15 pF  
CL = 15 pF  
CL = 15 pF  
CL = 15 pF  
VCN = 300 V  
tPSK  
tR  
tF  
2
ns  
2
ns  
Common Mode Transient Immunity  
(Output Logic High to Logic Low)(4)  
Channel to Channel Skew  
|CMH|,|CML|  
20  
30  
kV/µs  
2
200  
3
240  
ns  
CL = 15 pF  
per channel  
Dynamic Power Consumption(6)  
µA/MHz  
5 Volt Electrical Specifications  
Electrical Specifications are Tmin to Tmax  
Parameters  
Symbol  
Min.  
Typ.  
30  
Max.  
50  
Units  
µA  
Test Conditions  
Input Quiescent Current  
IL260  
IL261  
IL260  
IL261  
IDD1  
2.5  
10  
3.0  
15  
mA  
mA  
mA  
µA  
Output Quiescent Current  
IDD2  
8
12  
10  
Logic Input Current  
Logic High Output Voltage  
Ii  
VOH  
-10  
VDD-0.1  
0.8*VDD  
VDD  
VDD-0.5  
0
V
IO = -20 µA, VI=VIH  
IO = -4 mA, VI=VIH  
IO = 20 µA, VI=VIL  
IO = 4 mA, VI=VIL  
Logic Low Output Voltage  
VOL  
0.1  
0.8  
V
0.5  
Switching Specifications  
Maximum Data Rate  
Minimum Pulse Width  
100  
10  
110  
Mbps  
ns  
ns  
CL = 15 pF  
50% Points, VO  
CL = 15 pF,  
PW  
tPHL  
Propagations Delay Input to Output  
(High to Low)  
10  
15  
15  
Propagations Delay Input to Output  
tPLH  
10  
ns  
CL = 15 pF,  
(Low to High)  
(2)  
Pulse Width Distortion |tPHL-tPLH  
Propagation Delay Skew (3)  
Output Rise Time (10-90%)  
Output Fall Time (10-90%)  
|
PWD  
2
4
3
6
3
3
ns  
ns  
CL = 15 pF  
CL = 15 pF  
CL = 15 pF  
CL = 15 pF  
VCN = 300 V  
tPSK  
tR  
tF  
1
ns  
1
ns  
Common Mode Transient Immunity  
(Output Logic High to Logic Low)  
Channel to Channel Skew  
|CMH|,|CML|  
20  
30  
kV/µs  
2
280  
3
340  
ns  
CL = 15 pF  
per channel  
Dynamic Power Consumption(6)  
µA/MHz  
4
IL260 IL261  
Notes: (Apply to both 3.3 V and 5 V specifications.)  
1. Absolute Maximum ambient operating temperature means the device will not be damaged if operated under these conditions. It  
does not guarantee performance.  
2. PWD is defined as | tPHL– tPLH |. %PWD is equal to the PWD divided by the pulse width.  
3. tPSK is equal to the magnitude of the worst case difference in tPHL and/or tPLH that will be seen between units at 25°C.  
4. CMH is the maximum common mode voltage slew rate that can be sustained while maintaining VO > 0.8 VDD. CML is the  
maximum common mode input voltage that can be sustained while maintaining VO < 0.8 V. The common mode voltage slew  
rates apply to both rising and falling common mode voltage edges.  
5. Device is considered a two terminal device: pins 1-8 shorted and pins 9-16 shorted.  
6. Dynamic power consumption numbers are calculated per channel and are supplied by the channel’s input side power supply.  
5
IL260 IL261  
Application Notes  
Dynamic Power Consumption  
Data Transmission Rates  
Isoloop® devices achieve their low power consumption from  
the manner by which they transmit data across the isolation  
barrier. By detecting the edge transitions of the input logic  
signal and converting these to narrow current pulses, a  
magnetic field is created around the GMR Wheatstone  
bridge. Depending on the direction of the magnetic field, the  
bridge causes the output comparator to switch following the  
input logic signal. Since the current pulses are narrow, about  
2.5ns wide, the power consumption is independent of mark-  
to-space ratio and solely dependent on frequency. This has  
obvious advantages over optocouplers whose power  
consumption is heavily dependent on its on-state and  
frequency.  
The reliability of a transmission system is directly related to  
the accuracy and quality of the transmitted digital  
information. For a digital system, those parameters which  
determine the limits of the data transmission are pulse width  
distortion and propagation delay skew.  
Propagation delay is the time taken for the signal to travel  
through the device. This is usually different when sending a  
low-to-high than when sending a high-to-low signal. This  
difference, or error, is called pulse width distortion (PWD)  
and is usually in ns. It may also be expressed as a  
percentage:  
PWD% = Maximum Pulse Width Distortion (ns) x 100%  
Signal Pulse Width (ns)  
The approximate power supply current per channel for  
For example: For data rates of 12.5 Mb  
PWD% = 3 ns x 100% = 3.75%  
80 ns  
Power Supply Decoupling  
This figure is almost three times better than for any available  
optocoupler with the same temperature range, and two times  
better than any optocoupler regardless of published  
temperature range. The IsoLoop® range of isolators will run  
at almost 35 Mb before reaching the 10% limit.  
Both power supplies to these devices must be decoupled  
with low ESR 100 nF ceramic capacitors. For data rates in  
excess of 10MBd, use of ground planes for both GND1 and  
GND2 is highly recommended. Capacitors should be  
located as close as possible to the device.  
Propagation delay skew is the difference in time taken for  
two or more channels to propagate their signals. This  
becomes significant when clocking is involved since it is  
undesirable for the clock pulse to arrive before the data has  
settled. A short propagation delay skew is therefore critical,  
especially in high data rate parallel systems, to establish and  
maintain accuracy and repeatability. The IsoLoop® range of  
isolators all have a maximum propagation delay skew of 6  
ns, which is five times better than any optocoupler. The  
maximum channel-to-channel skew in the IsoLoop® coupler  
is only 3 ns which is ten times better than any optocoupler.  
Signal Status on Start-up and Shut Down  
To minimize power dissipation, the input signals are  
differentiated and then latched on the output side of the  
isolation barrier to reconstruct the signal. This could result  
in an ambiguous output state depending on power up,  
shutdown and power loss sequencing. Therefore, the  
designer should consider the inclusion of an initialization  
signal in his start-up circuit. Initialization consists of  
toggling each channel either high then low or low then high,  
depending on the desired state.  
6
IL260 IL261  
Application Diagrams  
Figure 1 Single Channel ∆Σ  
Figure 1 shows a typical single channel ∆Σ ADC  
application. The A/D is located on the bridge with no  
signal conditioning electronics between the bridge  
sensor and the ADC. In this application, the IL717 is  
the best choice for isolation. It isolates the control bus  
from the microcontroller. The system clock is located  
on the isolated side of the system.  
Figure 2 Multi Channel ∆Σ  
The second ∆Σ application is where multiple ADC's  
are configured in a channel-to-channel isolation  
configuration. The problem for designers is how to  
control clock jitter and edge placement accuracy of  
the system clock for each ADC. The best solution is  
to use a single clock on the system side and distribute  
this to each ADC. The IL261 adds a 5th channel to  
the IL717. This 5th channel is used to distribute a  
single, isolated clock to multiple ADC's as shown in  
Figure 2.  
7
IL260 IL261  
Package drawings, dimensions and specifications  
0.15’’ 16-pin SOIC  
0.3’’ 16-pin SOIC  
8
IL260 IL261  
Ordering information and valid part numbers.  
9
IL260 IL261  
About NVE  
An ISO 9001 Certified Company  
NVE Corporation is a high technology components manufacturer having the unique capability to combine leading edge Giant  
Magnetoresistive (GMR) materials with integrated circuits to make high performance electronic components. Products include  
Magnetic Field Sensors, Magnetic Field Gradient Sensors (Gradiometer), Digital Magnetic Field Sensors, Digital Signal Isolators  
and Isolated Bus Transceivers.  
NVE is a leader in GMR research and in 1994 introduced the world’s first products using GMR material, a line of GMR magnetic  
field sensors that can be used for position, magnetic media, wheel speed and current sensing.  
NVE is located in Eden Prairie, Minnesota, a suburb of Minneapolis. Please visit our Web site at www.nve.com or call 952-829-  
9217 for information on products, sales or distribution.  
NVE Corporation  
11409 Valley View Road  
Eden Prairie, MN 55344-3617 USA  
Telephone: (952) 829-9217  
Fax: (952) 829-9189  
Internet: www.nve.com  
e-mail: isoinfo@nve.com  
The information provided by NVE Corporation is believed to be accurate. However, no responsibility is assumed by NVE  
Corporation for its use, nor for any infringement of patents, nor rights or licenses granted to third parties, which may result from  
its use. No license is granted by implication, or otherwise, under any patent or patent rights of NVE Corporation. NVE  
Corporation does not authorize, nor warrant, any NVE Corporation product for use in life support devices or systems or other  
critical applications. The use of NVE Corporation’s products in such applications is understood to be entirely at the customer’s  
own risk.  
Specifications shown are subject to change without notice.  
ISB-DS-001-IL260/1-A  
January 17, 2005  
10  

相关型号:

IL260-3BTR13

High Speed Five Channel Digital Coupler
ETC

IL260-3BTR7

High Speed Five Channel Digital Coupler
ETC

IL260-3E

High Speed Five Channel Digital Couplers
ETC

IL260-3ETR13

High Speed Five Channel Digital Couplers
ETC

IL260-3ETR7

High Speed Five Channel Digital Couplers
ETC

IL260-3TR13

High Speed Five Channel Digital Couplers
ETC

IL260-3TR7

High Speed Five Channel Digital Couplers
ETC

IL260B

High Speed Five Channel Digital Couplers
ETC

IL260BE

High Speed Five Channel Digital Couplers
ETC

IL260BETR13

High Speed Five Channel Digital Couplers
ETC

IL260BETR7

High Speed Five Channel Digital Couplers
ETC

IL260BTR13

High Speed Five Channel Digital Coupler
ETC