JA1A-TMP-AC115 [ETC]

;
JA1A-TMP-AC115
型号: JA1A-TMP-AC115
厂家: ETC    ETC
描述:

文件: 总4页 (文件大小:92K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
1 HORSE-POWER  
COMPACT POWER RELAYS  
JA-RELAYS  
30.1  
1.185  
30.1  
1.185  
FEATURES  
• High switching capacity — 55 A inrush, 15 A steady state  
inductive load (1 Form A)  
34.7  
1.366  
34.7  
1.366  
28.5  
1.122  
28.5  
1.122  
• Particularly suitable for air conditioners, dish washers, mi-  
crowave ovens, ranges, central cleaning systems, copiers,  
facsimiles, etc.  
• Two types available  
"TM" type for direct chassis mounting  
"TMP" type for PC board mounting  
TMP type  
TM type  
• TV-rated types available  
• TÜV also approved  
mm inch  
SPECIFICATIONS  
Contact  
Characteristics  
Arrangement  
1 Form, A, 1 Form B, 1 Form C  
Maximum operating speed  
Initial insulation resistance*1  
20 cpm.  
Min. 100 Mat 500 V DC  
1,500 Vrms  
Initial contact resistance, max.  
(By voltage drop 6 V DC 1 A)  
30 mΩ  
Between open contacts  
Initial break-  
down voltage*2  
Contact material  
Silver alloy  
3,750 VA  
250 V AC  
15A  
Between contacts and coil  
2,000 Vrms  
Maximum switching power  
Rating  
(resistive Maximum switching voltage  
Initial surge voltage between contacts  
and coil*3  
Operate time*4  
(at 20°C) (at nominal voltage)  
Release time (without diode)*4  
Min. 5,000 V  
Approx. 10 ms*5  
Approx. 2 ms*5  
Max. 70°C  
load)  
Max. switching current  
Mechanical (at 180 cpm.)  
5×106  
1 Form A (Inrush 55 A,  
Steady 15 A 250 VAC  
cosϕ = 0.7)  
(at 20°C) (at nominal voltage)  
Expected  
life (min.  
operations)  
105  
Temperature rise (at 50°C)  
(resistive)  
Electrical  
(at 20 cpm.)  
1 Form B, 1 Form C  
(15 A 250 VAC,  
cosϕ = 1)  
5×105  
Functional*6  
98 m/s2 {10 G}  
980 m/s2 {100 G}  
88.2 m/s2 {9 G}, 10 to 55 Hz  
at double amplitude of 1.5 mm  
88.2 m/s2 {9 G}, 10 to 55 Hz  
at double amplitude of 1.5 mm  
Shock resis-  
Destructive*7  
Functional*8  
tance  
Coil  
Vibration  
DC type  
AC type  
DC type  
AC type  
1.2 W  
Nominal operating  
power  
resistance  
1.4 VA (50 Hz)/1.3 VA (60 Hz)  
0.77 W  
Destructive  
Minimum operating  
power  
Conditions for operation,  
transport and storage*9  
(Not freezing and condens-  
ing at low temperature)  
Ambient  
temp.  
–10°C to +50°C  
+14°F to +122°F  
0.90 VA (50 Hz)/0.84 VA (60 Hz)  
Remarks  
Humidity  
5 to 85%R.H.  
* Specifications will vary with foreign standards certification ratings.  
*1 Measurement at same location as "Initial breakdown voltage" section  
*2 Detection current: 10mA  
Unit weight  
Approx. 44 g 1.55 oz  
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981  
*4 Excluding contact bounce time  
*7 Half-wave pulse of sine wave: 6ms  
*8 Detection time: 10µs  
*9 Refer to 5. Conditions for operation, transport and storage mentioned in  
AMBIENT ENVIRONMENT (Page 24).  
*5 For the AC coil types, the operate/release time will differ depending on the phase.  
*6Half-wave pulse of sine wave: 11ms; detection time: 10µs  
TYPICAL APPLICATIONS ORDERING INFORMATION  
Air conditioners, microwave ovens, load  
management equipment, copiers, process  
control equipment  
Ex. JA  
1a  
TM  
DC12V  
P
Contact  
arrangement  
Mounting classification  
Coil voltage  
Classification  
Nil: Standard type  
P: Up-graded contact  
rating type  
1c: 1 Form C  
1a: 1 Form A  
1b: 1 Form B  
TM: Solder Terminal  
TMP: Solder Teminal  
and PCB Teminal  
DC 12, 24 V  
AC 12, 24, 115 V  
(See next page)  
(Notes) 1. For UL/CSA recognized types, add suffix UL/CSA.  
(Notes) 2. Standard packing Carton: 20 pcs.; Case: 200 pcs.  
110  
JA  
COIL DATA  
DC Type at 20°C 68°F  
Nominal  
voltage  
Pick-up voltage  
Drop-out* voltage  
(min.)  
Coil resistance,  
W (±10%)  
Nominal operating Nominal operating Maximum allowable  
(max.)  
current, mA (±10%)  
power  
1.2 W  
1.2  
voltage (at 50°C)  
13.2 V DC  
26.4  
12 V DC  
24  
9.6 V DC  
1.2 (0.6*) V DC  
2.4 (1.2*)  
120  
480  
100  
50  
19.2  
AC Type at 20°C 68°F  
Nominal  
voltage  
Pick-up voltage  
(max.)  
Drop-out* voltage  
(min.)  
Coil resistance,  
W (±10%)  
Nominal operating Nominal operating Maximum allowable  
current, mA (±10%)  
power  
voltage (at 50°C)  
50 Hz  
117  
58  
60 Hz  
108  
54  
50 Hz  
60 Hz  
1.3 VA  
1.3 VA  
1.3 VA  
12 V AC  
9.6 V AC  
3.6 V AC  
13.2 V DC  
1.4 VA  
1.4 VA  
1.4 VA  
24  
19.2  
92  
7.2  
26.4  
115  
34.5  
12  
11  
126.5  
* Drop-out voltage for 1 Form B type is 5% of nominal voltage.  
NOTES  
3. When the operating voltage of AC relays drops be-  
low 80% of the nominal coil voltage.The relay will gen-  
erate a considerable amount of heat which is not  
recommended for maximum efficiency.  
4.The coil resistance of DC types is the measured val-  
ue of the coil at a temperature of 20°C (68°F). If the  
coil temperature changes by ±1°C.The measured val-  
ue of the coil resistance should be increased or de-  
creased by 0.4%.  
1. The range of coil current for AC relay is ±15% (60  
Hz). For DC relay it is ±10% at 20°C 68°F.  
2. The JA relay will operate in a range from 80% to  
110% of the nominal coil voltage. It is however, recom-  
mended that the relay be used in the range of 85% to  
110% of the nominal coil voltage, with the temporary  
voltage variation taken into consideration.  
ADDITIONAL SERIES  
1. Following up-graded contact rating types recognized by  
UL are available. (For use in office appliances)  
2.TV-Rated Series  
Suffix  
Suffix  
UL  
TV  
CSA  
TV  
Contact  
arrangement  
Contact  
arrangement  
P
(Ex. JA 1a - TM - DC12V -P)  
1 Form C  
25 A 250 V AC, 1 HP 125, 250 V AC  
25 A 250 V AC, 1 HP 125, 250 V AC  
25 A 250 V AC, 1 HP 125, 250 V AC  
1 Form A  
TV-5  
TV-5  
1 Form A  
1 Form B  
mm inch  
DIMENSIONS  
TM  
Schematic (Bottom view)  
4.5  
COM  
.177  
1 Form A  
N.O.  
COM  
50  
1.969  
43.5  
COM  
1.713  
1 Form B  
N.C.  
34.7  
30.1  
1.185  
COM  
1.366  
2
1 Form C  
.079  
37.8  
1.488  
N.C. N.O.  
6.5  
.256  
9.3  
.366  
Terminals—.187" quick connect terminals for coil  
and .250" for contacts  
FASTON 250  
FASTON 187  
21.5  
.846  
12.7  
.500  
Mounting hole location  
43.5±0.1  
COM  
1.713±.004  
2-4.5±0.1 DIA.  
2-.177±.004 DIA.  
Remarks  
Above dimensions are for 1 Form C type.  
For 1 Form A type, NC terminal is removed  
For 1 Form B type, NO terminal is removed.  
NC  
NO  
Tolerance: ±0.1 ±.004  
General tolerance: ±0.3 ±.012  
111  
JA  
TMP  
mm inch  
4.5  
Schematic  
1 Form A  
Bottom view  
Top view  
.177  
0.5±0.1  
.020±.004  
0.5±0.1  
.020±.004  
COM  
COM  
50  
1.969  
43.5  
N.O.  
1.713  
C O M  
Bottom view  
Top view  
COM  
COM  
0.8±0.1  
.031±.004  
34.7  
1.366  
14  
.551  
1 Form B  
1 Form C  
25.4  
1.000  
3.5  
.138  
1.5  
.059  
30.1  
1.185  
N.C.  
2
Bottom view  
Top view  
.079  
37.8  
1.488  
COM  
COM  
9.3  
.366  
FASTON 250  
21.5  
.846  
12.7  
N.O. N.C.  
.500  
Terminals—PC board terminals for coils and  
.250" quick connect terminals forcontacts  
COM  
Mounting hole location  
3-2±0.1 DIA.  
3-.079±.004 DIA.  
NC  
NO  
43.5±0.1  
1.713±.004  
14±0.1  
2-4.5±0.1 DIA.  
2-.177±.004 DIA.  
.551±.004  
General tolerance: ±0.3 ±.012  
Remarks  
25.4±0.1  
1.000±.004  
Above dimensions are for 1 Form C type.  
For 1 Form A type, NC terminal is removed  
For 1 Form B type, NO terminal is removed.  
Tolerance: ±0.1 ±.004  
REFERENCE DATA  
1. Maximum value for switching capacity  
(Common for 1a, 2b, and 1c)  
2. Life curve (Common for 1a, 1b, and 1c)  
3.-(1) Coil temperature rise (1a-AC type)  
Point measured: Inside the coil  
Ambient temperature: 25°C 77°F  
20  
AC resistive load  
500  
100  
10  
Contact current  
15A  
5
80  
60  
40  
20  
10A  
0A  
DCresistive load  
250 V AC resistive load  
30 V DC resistive load  
100  
1
50  
0.5  
0
30 50 100 200 400500  
Contact voltage, V  
0
2
4
6
8
10 12 14 16 18 20 22  
Contact current, A  
0
80  
90  
100  
110  
120  
Coil applied voltage, %V  
3.-(2) Coil temperature rise (1a-DC type)  
4.-(1) Operate time (1a-AC type)  
4.-(2) Operate time (1a-DC type)  
Point measured: Inside the coil  
Ambient temperature: 25°C 77°F  
20  
18  
16  
14  
12  
10  
8
20  
18  
16  
14  
12  
10  
8
100  
Contact current  
15A  
80  
60  
40  
20  
10A  
0A  
Max.  
Min.  
Max.  
Min.  
6
6
4
4
2
2
0
80  
90  
100  
110  
120  
0
80  
90  
100 110 120  
0
80  
90  
100 110 120  
Coil applied voltage, %V  
Coil applied voltage, %V  
Coil applied voltage, %V  
112  
JA  
5.-(1) Release time (1a-AC type)  
5.-(2) Release time (1a-DC type)  
20  
18  
16  
14  
12  
10  
8
5
4
3
2
1
Max.  
Min.  
Max.  
Min.  
6
4
2
0
80  
90  
100  
110  
120  
0
80  
90  
100 110 120  
Coil applied voltage, %V  
Coil applied voltage, %V  
2. Contact resistance  
6.-(1) Electrical life (15 A 250 V AC resistive)  
TEST RESULT:  
1. Tested sample: JA1c-TMP-AC115V  
2. Load: 15 A 250 V AC resistive load  
3. Cycle rate: 20 cpm.  
1. Pick-up and drop-out voltage  
30  
Max.  
80  
4. Circuit:  
Mean  
value  
Pick-up voltage  
Drop-out voltage  
70  
60  
50  
40  
30  
20  
N.C. contact  
Max.  
Max.  
Min.  
Min.  
10  
0
Min.  
10  
30  
50  
No. of operations, ×104  
30  
N.C.  
N.C.  
15 A  
15 A  
250 V AC  
N.C. contact  
10  
0
10  
0
Mean  
value  
10  
30  
50  
No. of operations, ×104  
10  
30  
No. of operations, ×104  
* This shows percent rate against nominal coil voltage.  
50  
3. No abnormality was observed in either insulation  
resistance or breakdown voltage.  
2. Contact resistance  
6.-(2) Electrical life (15 A 250 V AC Motor sim-  
ulated load)  
TEST RESULT:  
1. Pick-up and drop-out voltage  
1. Tested sample: JA1a-TM-DC12V  
2. Load: 250 V AC inductive load (cosϕ = 0.7)  
15 A steady and 55 A (0.3s*) inrush current  
3. Cycle rate: 20 cpm.  
10  
10  
9
8
7
6
5
4
3
2
1
0
Pick-up voltage  
Max.  
Mean value  
Min.  
N.O. contact  
Max.  
Mean value  
Min.  
4. Circuit:  
5
0
N.O.  
Drop-out voltage  
R
Max.  
Mean value  
Min.  
R
L
250 V AC  
L
5
10  
5
10  
No. of operations, ×104  
No. of operations, ×104  
3. No abnormality was observed in either insulation  
resistance or breakdown voltage.  
For Cautions for Use, see Relay Technical Information (Page 11 to 39).  
113