JLLN/JLLS POWR-TClass T Fuses  
300/600 VAC Fast-Acting 1 1200 Amperes  
SPECIFICATIONS  
Voltage ratings: AC: 300 Volts (JLLN); 600 Volts (JLLS)  
DC: 125 Volts (JLLN 110 1200A);  
300 Volts (JLLS)  
Interrupting ratings:AC: 200,000 amperes rms symmetrical  
DC: 20,000 amperes (JLLN 110 1200A)  
(JLLS 1 1200A)  
GENERAL  
PURPOSE  
FUSES  
Ampere range: 11200 amperes  
Approvals: AC: UL Listed Class T per UL 248  
(formerly UL 198H)  
(File No. E81895): JLLN/JLLS (1 800A)  
UL Recognized (  
) (File No. E71611):  
JLLS (900 1200A)  
CSA Certified HRCI-T (File No. LR29862):  
JLLN/JLLS (1 600A)  
DC: Additionally UL Listed per UL 198L:  
JLLN (110 1200A) (File No. E81895)  
JLLS 300 VDC is Littelfuse self-certified  
AMPERE RATINGS  
1
2
3
6
10  
15  
20  
25  
30  
35  
40  
45  
50  
60  
70  
80  
90  
100  
110  
125  
150  
175  
200  
225  
250  
300  
350  
400  
450  
500  
600  
700  
800  
1000  
1100  
1200  
*
JLLS only.  
*
Example part number (series & amperage): JLLS 100  
RECOMMENDED FUSE BLOCKS  
LT300 series (for JLLN series fuses)  
LT600 series (for JLLS series fuses)  
Space saving POWR-Tfuses are the most compact fuses  
available in ratings above 30 amperes less than one-third  
the size of comparable Class R fuses. When rated in accor-  
dance with the NEC, POWR-T fuses provide fast-acting  
overload and short circuit protection for non-inductive circuits  
and equipment. Used in inductive circuits, the ampere rating  
of POWR-T fuses must be increased to prevent opening on  
inrush currents. In such instances, POWR-T fuses may  
provide only short circuit protection.  
Refer to Fuse Block section of this catalog for additional infor-  
mation.  
Extremely current limiting Stops damaging short circuit  
current faster than any mechanical protective device.  
Fast-acting Provides fast-acting overload protection to  
equipment such as variable speed drives, rectifiers and  
other equipment containing surge-sensitive components.  
For motor and general purpose circuits where space is not  
critical, we recommend POWR-PRO® JTD_ID Indicator  
series, LLNRK/LLSRK series, or FLSR_ID Indicator series.  
LONGER EQUIPMENT LIFE  
APPLICATIONS  
Current limiting design greatly reduces damage to equip-  
ment caused by heating and magnetic effects of short  
circuit currents.  
Protection of individual electric services and meters.  
Main switches containing Class T fuses may be used to  
provide compact protection for meter stacks.  
ECONOMICAL  
Molded case circuit breaker load centers and panelboards  
have increased interrupting ratings when series ratedwith  
Littelfuse Class T fuses. Refer to panelboard manufacturers’  
literature for UL Listed combination of fuses and panelboards.  
Series ratings up to 200,000 amperes are available.  
Extremely current limiting design often permits use of  
readily available, less costly equipment.  
Used as input or output fuses for surge-sensitive compo-  
nents, such as variable speed drives and rectifiers, fast-  
acting POWR-T JLLN/JLLS fuses may prevent opening of  
expensive semiconductor fuses protecting individual  
components.  
SPACE-SAVING  
Typical three-pole Class T fuse blocks require less than 50%  
of the panel area required for Class R fuse blocks. Switch  
enclosures, fuse pullouts, and other equipment using Class T  
fuses are often correspondingly more compact.  
NOTE: JLLN Class T 300 volt fuses are UL listed for circuits  
not exceeding 300 volts to ground. However, since UL does  
not include testing 300 volt Class T fuses on 277/480 volt  
three-phase bolted faults, Littelfuse does not recommend  
using 300 volt Class T fuses where phase-to-phase voltage  
exceeds 300 volts.  
SAFETY  
200,000 A.I.R. Reliable interruption of all overcurrents up  
to 200,000 amperes.  
39  
JLLN/JLLS POWR-TClass T Fuses  
300/600 VAC Fast-Acting 1 1200 Amperes  
C
G
B
GENERAL  
PURPOSE  
FUSES  
D
B
D
C
F
C
A
F
E
A
D
A
Fig. 1  
Fig. 2  
Fig. 3  
DIMENSIONS IN INCHES (mm in parentheses)  
REFER TO  
FIG. NO.  
AMPERES  
SERIES  
A
B
C
D
E
F
G
7/8  
(22.2)  
9/32  
(7.1)  
13/32  
(10.3)  
JLLN  
JLLS  
JLLN  
JLLS  
JLLN  
JLLS  
JLLN  
JLLS  
JLLN  
JLLS  
JLLN  
JLLS  
JLLN  
JLLS  
JLLN  
JLLS  
1
1 30  
1-1/2  
(38.1)  
9/32  
(7.1)  
9/16  
(14.3)  
7/8  
(22.2)  
9/32  
(7.1)  
9/16  
(14.3)  
1
2
35 60  
70 100  
1-9/16  
(39.7)  
13/16  
(20.6)  
13/32  
(10.3)  
1
1/16  
(1.6)  
1-3/32  
(27.8)  
(25.4)  
2-5/32  
(54.8)  
1-9/16  
(39.7)  
3/4  
(19.1)  
13/16  
(20.6)  
27/32  
(21.4)  
9/32  
(7.1)  
1/8  
(3.2)  
3
2-61/64  
(75.0)  
2-23/64  
(59.9)  
3/4  
(19.1)  
13/16  
(20.6)  
1-41/64  
(41.7)  
9/32  
(7.1)  
1/8  
(3.2)  
2-7/16  
(61.9)  
1-11/16  
(42.9)  
7/8  
(22.2)  
1-1/16  
(27.0)  
27/32  
(21.4)  
11/32  
(8.7)  
3/16  
(4.8)  
3
3
3
3
3
110 200  
225 400  
450 600  
700 800  
900 1200  
3-1/4  
(82.6)  
2-1/2  
(63.5)  
7/8  
(22.2)  
1-1/16  
(27.0)  
1-21/32  
(42.1)  
11/32  
(8.7)  
3/16  
(4.8)  
2-3/4  
(69.9)  
1-27/32  
(46.8)  
1
1-5/16  
(33.3)  
53/64  
(21.0)  
13/32  
(10.3)  
1/4  
(6.4)  
(25.4)  
3-5/8  
(92.1)  
2-23/32  
(69.1)  
1
1-19/32  
(40.5)  
1-23/32  
(43.7)  
13/32  
(10.3)  
1/4  
(6.4)  
(25.4)  
3-1/16  
(77.8)  
2-1/32  
(51.6)  
1-1/4  
(31.8)  
1-19/32  
(40.5)  
7/8  
(22.2)  
31/64  
(12.3)  
5/16  
(7.9)  
3-63/64  
(101.2)  
2-61/64  
(75.0)  
1-1/4  
(31.8)  
2-1/16  
(52.4)  
1-49/64  
(44.8)  
31/64  
(12.3)  
5/16  
(7.9)  
3-3/8  
(85.7)  
2-7/32  
(64.3)  
1-3/4  
(44.5)  
2-1/16  
(52.4)  
7/8  
(22.2)  
35/64  
(13.9)  
3/8  
(9.5)  
4-21/64  
(109.9)  
3-11/64  
(80.6)  
1-3/4  
(44.5)  
2-1/2  
(63.5)  
1-55/64  
(47.2)  
35/64  
(13.9)  
3/8  
(9.5)  
4
2-17/32  
(64.3)  
2
2-1/2  
(63.5)  
1-1/32  
(26.2)  
39/64  
(15.5)  
7/16  
(11.1)  
(101.6)  
(50.8)  
5.27  
(133.9)  
3.80  
(96.5)  
2
2.63  
(66.8)  
2.30  
(58.4)  
.67  
(15.5)  
.44  
(11.2)  
(50.8)  
40  
JLLN/JLLS POWR-TClass T Fuses  
300/600 VAC Fast-Acting 1 1200 Amperes  
JLLN  
JLLS  
1000  
800  
600  
1000  
800  
600  
GENERAL  
PURPOSE  
FUSES  
400  
300  
400  
300  
200  
200  
100  
80  
60  
100  
80  
60  
40  
30  
40  
30  
20  
20  
10  
8
6
10  
8
6
4
3
4
3
2
2
1
1
.8  
.8  
.6  
.6  
.4  
.3  
.4  
.3  
.2  
.2  
.1  
.1  
.08  
.08  
.06  
.06  
.04  
.03  
.04  
.03  
.02  
.02  
.01  
.01  
CURRENT IN AMPERES  
CURRENT IN AMPERES  
JLLN  
JLLS  
1000000  
800000  
1000000  
800000  
600000  
600000  
400000  
300000  
400000  
300000  
200000  
200000  
100000  
80000  
100000  
80000  
60000  
60000  
800A  
600A  
1200A  
800A  
600A  
400A  
40000  
30000  
40000  
30000  
400A  
200A  
20000  
20000  
200A  
100A  
100A  
60A  
10000  
8000  
6000  
10000  
8000  
6000  
60A  
30A  
30A  
4000  
3000  
4000  
3000  
2000  
2000  
1000  
800  
1000  
800  
600  
600  
400  
300  
400  
300  
200  
200  
100  
100  
AVAILABLE FAULT CURRENT  
SYMMETRICAL R. M. S. AMPERES  
AVAILABLE FAULT CURRENT  
SYMMETRICAL R. M. S. AMPERES  
41  

相关型号:

ETC

JLLN100

Electric Fuse, Fast Blow, 100A, 300VAC, 200000A (IR), Inline/holder, ROHS COMPLIANT
LITTELFUSE

JLLN100.VXP

Electric Fuse
LITTELFUSE

JLLN1000

Electric Fuse, Fast Blow, 1000A, 300VAC, 125VDC, 200000A (IR), Inline/holder, ROHS COMPLIANT
LITTELFUSE

JLLN100P

Electric Fuse
LITTELFUSE

JLLN110

Electric Fuse, Fast Blow, 110A, 300VAC, 125VDC, 200000A (IR), Inline/holder, ROHS COMPLIANT
LITTELFUSE

JLLN1100

Electric Fuse, Fast Blow, 1100A, 300VAC, 125VDC, 200000A (IR), Inline/holder, ROHS COMPLIANT
LITTELFUSE

JLLN1200

Electric Fuse, Fast Blow, 1200A, 300VAC, 125VDC, 200000A (IR), Inline/holder, ROHS COMPLIANT
LITTELFUSE

JLLN125

Electric Fuse, Fast Blow, 125A, 300VAC, 125VDC, 200000A (IR), Inline/holder, ROHS COMPLIANT
LITTELFUSE
ETC

JLLN150

Electric Fuse, Fast Blow, 150A, 300VAC, 125VDC, 200000A (IR), Inline/holder, ROHS COMPLIANT
LITTELFUSE

JLLN150.XXP

FUS 300V F/A CLASS T 150A PLTD
LITTELFUSE