JLS20 [ETC]

Fuse ; 保险丝\n
JLS20
型号: JLS20
厂家: ETC    ETC
描述:

Fuse
保险丝\n

电路保护
文件: 总2页 (文件大小:406K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
JLS CLASS J FUSES  
600 VAC Fast-Acting 1 600 Amperes  
SPECIFICATIONS  
Voltage ratings: 600 Volts AC  
Interrupting ratings: 200,000 amperes rms symmetrical  
Ampere range: 1600 amperes  
GENERAL  
PURPOSE  
FUSES  
Approvals: UL Listed Class J fuses per UL 248  
(formerly UL 198C)  
(File No. E81895)  
CSA Certified HRCI-J (File No. LR29862)  
Federal Specification No. WF1814 (QPL)  
AMPERE RATINGS  
1
3
6
10  
15  
20  
25  
30  
35  
40  
45  
50  
60  
70  
80  
90  
100  
110  
125  
150  
175  
200  
225  
250  
300  
350  
400  
450  
500  
600  
Example part number (series & amperage): JLS 110  
RECOMMENDED FUSE BLOCKS  
LJ600 series  
Refer to Fuse Block section of this catalog for additional infor-  
mation.  
JLS series fuses provide space-saving, fast-acting overload  
and short-circuit protection for non-inductive loads. When  
used for motors or other inductive loads, the ampere rating of  
JLS series fuses must be increased to prevent nuisance  
opening on inrush currents. In such applications, JLS fuses  
may provide only short circuit protection. Consider using  
Littelfuse POWR-PRO® JTD series time-delay fuses in such  
circuits.  
LONGER EQUIPMENT LIFE  
Current-limiting design reduces damage to equipment  
caused by heating and magnetic effects of short-circuit  
currents.  
ECONOMICAL  
Extremely current-limiting design often permits use of  
readily available, less costly equipment.  
APPLICATIONS  
Manufacturers of equipment containing dual voltage  
devices can simplify manufacturing and reduce inventory  
by standardizing on 600 volt JLS fuses and Class J fuse  
blocks for all AC voltage ratings.  
General purpose circuits with little or no motor load.  
Resistive loads, such as resistance electric heat.  
Loads requiring fast-acting overload protection, such as  
equipment containing solid-state devices.  
EASY TO USE  
200,000 A.I.R. rating minimizes need for short-circuit  
calculations.  
SPACE SAVING  
JLS fuse characteristics are similar to KLNR/KLSR fast-  
NOTE: Littelfuse JLS fuses are not time-delay fuses. For  
applications where short-duration surges and spikes may  
cause nuisance fuse opening, consider the use of Littelfuse  
POWR-PRO® JTD series time-delay fuses.  
acting Class RK1 fuses, but they are much smaller.  
SAFETY  
200,000 A.I.R. Reliable interruption of all overcurrents up  
to 200,000 amperes.  
Extremely current limiting Stops damaging short-circuit  
current faster than any mechanical protective device.  
Fast-acting Provides fast-acting protection to equipment  
such as variable speed drives, rectifiers and other equip-  
ment containing surge-sensitive components.  
37  
JLS CLASS J FUSES  
600 VAC Fast-Acting 1 600 Amperes  
C
D
A
G
F
H
A
B
C
D
GENERAL  
PURPOSE  
FUSES  
E
Fig. 2  
Fig. 1  
DIMENSIONS IN INCHES (mm in parentheses)  
REFER TO  
FIG. NO.  
AMPERES  
A
B
C
D
E
F
G
H
2-1/4  
(57.2)  
1/2  
(12.7)  
13/16  
(20.6)  
1 30  
1
1
2
2
2
2
2-3/8  
(60.3)  
5/8  
(15.9)  
1-1/16  
(27.0)  
35 60  
2-5/8  
(66.7)  
3-17/32  
(89.7)  
3-23/32  
(94.5)  
4-5/8  
(117.5)  
1
3/4  
(19.1)  
9/32  
(7.1)  
1/8  
(3.2)  
70 100  
110 200  
225 400  
450 600  
(25.4)  
3
4-9/32  
(108.7)  
4-15/32  
(113.5)  
5-3/4  
(146.1)  
1-1/2  
(38.1)  
1-1/8  
(28.6)  
9/32  
(7.1)  
3/16  
(4.8)  
(76.2)  
3-3/8  
(85.7)  
5-1/8  
(130.2)  
5-3/8  
(136.5)  
7-1/8  
(181.0)  
2
1-5/8  
(41.3)  
13/32  
(10.3)  
1/4  
(6.4)  
(50.8)  
3-3/4  
(95.3)  
5-27/32  
(148.4)  
6-5/32  
(156.4)  
8
2-1/2  
(63.5)  
2
17/32  
(13.5)  
3/8  
(9.5)  
(203.2)  
(50.8)  
1000  
800  
600  
1000000  
800000  
600000  
400  
300  
400000  
300000  
200  
200000  
100  
80  
60  
100000  
80000  
60000  
40  
30  
600A  
400A  
40000  
30000  
20  
20000  
200A  
10  
8
6
100A  
60A  
10000  
8000  
6000  
4
3
30A  
2
4000  
3000  
1
2000  
.8  
.6  
.4  
.3  
1000  
800  
600  
.2  
400  
300  
.1  
.08  
200  
.06  
.04  
.03  
100  
.02  
.01  
AVAILABLE FAULT CURRENT  
SYMMETRICAL R. M. S. AMPERES  
CURRENT IN AMPERES  
38  

相关型号:

JLS25

Fuse
ETC

JLS3

Fuse
ETC

JLS30

Fuse
ETC

JLS300

Electric Fuse, Fast Blow, 300A, 600VAC, 200000A (IR), Inline/holder,
LITTELFUSE

JLS35

Fuse
ETC

JLS40

Fuse
ETC

JLS45

Fuse
ETC

JLS50

Fuse
ETC

JLS6

Fuse
ETC

JLS60

Fuse
ETC

JLS70

Fuse
ETC

JLS80

Fuse