Technical Data10488  
Effective February 2016  
Class J modular ferrule and knifeblade  
fuse blocks  
Knifeblade fuse blocks from 100 to 600 amps  
feature phase barriers between poles for additional  
safety with up to four mounting holes per pole  
increase installation flexibility. All knifeblade blocks  
meet UL creep and clearance requirements for  
Industrial Power Circuits (UL 508 and UL 845).  
Additionally, the 200 to 600 amp blocks meet the  
higher UL creep and clearance requirements for  
Power Distribution Standards (UL 98, UL 67, UL  
489, UL 891 and UL 869A)  
All blocks have optional IP20 finger-safe high  
clarity, see-through covers for inspecting wire  
terminations or thermography measurements  
without removal. All covers enhance safety by  
featuring probe holes for easier, safer testing  
and a lockout/tagout capability. These covers  
also have optional open fuse indication to speed  
troubleshooting.  
Easy circuit identification is available for 30 and  
60 amp blocks and covers with universal marker  
labels.  
Specifications:  
Catalog symbol:  
•ꢀ  
Ratings  
JM60_  
•ꢀ  
Volts 600V  
Description:  
•ꢀ  
Amps up to 600  
Bussmann® series Class J modular fuse blocks  
increase versatility, reduce labor and enhance  
safety for any panel or electrical system design.  
Available for the full Class J fuse amp range.  
•ꢀ  
Withstand 200kA RMS Sym  
Agency information  
•ꢀ  
Blocks:  
These fuse blocks feature a standard fuse  
clip reinforcing spring for enhanced electrical  
contact between the blcok and fuse. All blocks  
are available as single-pole versions that snap  
together for the required number of poles, or as  
factory configured 2-, and 3-pole versions to meet  
stocking requirements.  
•ꢀ UL® Listed E14853 — IZLT and IZLT7  
•ꢀ CSA® Certified 47235-6225-01  
•ꢀ CE  
•ꢀ RoHS Compliant  
•ꢀ REACH declaration available upon request  
The modular design permits reducing inventory,  
assembly time and labor with tool-less assembly  
of multiple poles at point of use.  
•ꢀ  
Covers:  
•ꢀ UL Listed E58836 - JDVS  
•ꢀ CSA Certified 47235-6225-01 (30 and 60A)  
•ꢀ RoHS Compliant  
Ferrule fuse blocks up to 60 amps save panel  
space with the smallest width dimension on the  
market and feature DIN-Rail and panel mount  
versatility so that one product can be used for  
multiple applications with lower inventory cost.  
•ꢀ REACH declaration available upon request  
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Optional see-through covers provide IP20 finger-safe  
protection and feature a lockout/tagout provision  
to improve electrical safety. These covers are  
also available with open fuse indicating  
version for faster troubleshooting.  
Order separately, one cover per  
Poles  
•ꢀ  
1-, 2-, 3-pole units factory assembled  
•ꢀ  
Single-pole units snap together to create desired number of poles  
Flammability ratings  
block pole.  
•ꢀ  
Blocks: UL 94V0, self-extinguishing  
•ꢀ  
Covers: UL 94HB, self-extinguishing  
Operating and storage temperature range  
•ꢀ  
Blocks -40°C to +120°C  
•ꢀ  
Covers;  
•ꢀ Non-Indicating -40°C to +120°C  
•ꢀ Indicating -20°C to +90°C*  
* Indication requires minimum 90V and closed circuit to illuminate.  
Materials  
•ꢀ  
Base: Thermoplastic  
•ꢀ  
Terminals:  
•ꢀ Tin-plated copper brass (30 and 60A)  
•ꢀ Tin-plated aluminum (box lug)  
•ꢀ  
Covers: Thermoplastic  
Conductors  
Standard dual lugs on  
600A blocks and optional  
dual lugs on 400A blocks  
for easier wiring using two,  
smaller conductors.  
•ꢀ  
See catalog numbers for details and torque specifications.  
Modular Class J ferrule and knifeblade fuse blocks  
30 and 60 amp ferrule fuse blocks have DIN-rail and panel mounting capability,  
the modular designs allows blocks toand snap together for the desired number  
of poles. They accept optional snap-on covers for IP20 finger-safe protection and  
feature a lockout/tagout to improve electrical safety.  
On blocks rated from 100 to 600A, the optional covers can be completely removed  
for servicing or simply hinged open.  
100 to 600 amp knifeblade fuse blocks are panel mount with multiple holes for  
installation flexibility and the modular design allows blocks to snap together for the  
desired number of poles. They accept optional snap-on covers for IP20 finger-safe  
protection and feature a lockout/tagout provision to improve electrical safety.  
2
Eaton.com/bussmannseries  
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Table 1: 30 and 60 amp block catalog numbers  
Terminal type  
Fuse  
Optional covers*  
amp range Poles Box lug/slot screw Box lug/hex screw #10-32 Phil-slot screw Pressure plate Indicating**  
Non-indicating  
1
2
3
1
2
3
JM60030-1CR  
JM60030-2CR  
JM60030-3CR  
JM60060-1CR  
JM60060-2CR  
JM60060-3CR  
JM60030-1CHR  
JM60030-2CHR  
JM60030-3CHR  
JM60060-1CHR  
JM60060-2CHR  
JM60060-3CHR  
JM60030-1SR  
JM60030-2SR  
JM60030-3SR  
JM60030-1PR  
JM60030-2PR  
JM60030-3PR  
up to 30  
35 to 60  
CVRI-J-60030  
CVRI-J-60060  
CVR-J-60030  
CVR-J-60060  
*
Covers sold separately, one cover per pole.  
** Open fuse indication requires 90 volts minimum and closed circuit to operate.  
Table 2: 30 and 60 amp block terminals and conductors  
Recommended Bussmann series fuses:  
Terminal type  
AWG type/range AWG Torque N•m (lb-in)  
Description  
Amps  
Data sheet no.  
2-3  
4-6  
8
5.6 (50)  
5.1 (45)  
4.5 (40)  
Ultimate protection Low-Peak® LPJ time-  
up to 60 1006  
up to 600 1026  
delay fuses  
75°C  
Cu 2-14,  
AL 2-8  
Box lug  
Advanced protection Limitron™ JKS fast-  
acting fuses  
10-14 4.0 (35)  
Recommended accessories for 30 and 60 amp blocks:  
#10-32 Phil-slot  
screw  
75/90°C  
Cu 10-18  
10-18 2.3 (20)  
Description  
Catalog no.  
BRKT-ND  
Pressure plate  
DIN-Rail end stops  
Marker labels  
BRKT-NDSCREW2  
TM26CB  
Marker label provision for easy  
circuit dientification  
Finger grips on cover  
for easy removal  
Optional see-through, snap-on  
cover for easy visual inspection  
Standard phase barriers  
for additional safety  
Optional open fuse indication  
speeds troubleshooting  
Vent slots improve cooling*  
Toolless interlocking modular design  
for easy point-of-use assembly  
Lockout/tagout feature  
improves safety  
DIN-rail or panel mounting  
on each pole provides  
installation flexibility  
Probe holes for easy testing  
without removing cover  
*No fuse derating necessary.  
Eaton.com/bussmannseries  
3
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Dimensions; 30A Class J block - in (mm)  
55  
2.2  
28  
1.1  
R3  
.1  
87 12  
3.4 .5  
JM60030-1CR  
JM60030-2CR  
PROVISION FOR  
MARKING LABEL  
28  
1.1  
29  
56  
2.2  
1.1  
46  
1.8  
17  
.7  
58  
2.3  
PROVISION FOR  
MARKING LABEL  
83  
3.3  
CVR-J-60030  
(NON INDICATING)  
CVRI-J-60030  
(WITH INDICATION)  
110  
JM60030-3CR  
4.3  
84  
3.3  
LOCKOUT -  
TAGOUT RINGS  
JM60030-1CR  
SHOWN WITH COVER  
4
Eaton.com/bussmannseries  
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Dimensions; 60A Class J block - in (mm)  
39  
1.5  
76  
3.0  
7
.3  
R3  
.1  
94  
3.7  
JM60060-2CR  
JM60060-1CR  
5
.2  
18  
.7  
38  
1.5  
38  
75  
1.5  
3.0  
53  
2.1  
65  
2.6  
18  
.7  
PROVISION FOR  
MARKER LABEL  
PROVISION FOR  
MARKER LABEL  
114  
4.5  
PROVISION FOR  
MARKER LABEL  
CVR-J-60060  
(NON INDICATING)  
CVRI-J-60060  
(WITH INDICATION)  
119  
JM60060-3CR  
4.7  
113  
4.5  
LOCKOUT -  
TAGOUT RINGS  
JM60060-1CR  
SHOWN WITH COVER  
Eaton.com/bussmannseries  
5
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Installing/removing covers  
For larger conductors, trim center tab  
at notch as show in detail A.  
Install cover:  
Position cover  
over block and  
push straight  
down until it  
snaps/clicks  
into place.  
Trim tab  
here  
A
Open cover:  
Using both  
outside handles,  
pull straight up.  
Detail A  
Installing blocks on DIN-Rail  
Place one edge of DIN-Rail in fuse block base, then rotate block down until it clicks into place.  
6
Eaton.com/bussmannseries  
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Table 6: Class J 100 to 600 amp knifeblade blocks and covers  
Covers*  
Conductors***  
Fuse  
amp  
Torque  
range  
Poles  
Catalog nos.  
Indicating**  
Non-indicating  
Solid and stranded  
Fine stranded  
Cu 1-3 AWG  
Cu 4-6 AWG  
N•m (lb-in)  
6.2 (55)  
1
JM60100-1CR  
1/0-3 AWG; (2) Cu 4-6 AWG  
5.6 (50)  
70-100  
CVR-J-60100  
CVRI-J-60100  
2 4-6 AWG; (2) Cu 8 AWG  
Cu 8 AWG  
5.1 (45)  
2
JM60100-2CR  
8 AWG; (2) Cu 10-14 AWG  
Cu 10-14 AWG; Al 10-12 AWG  
250kcmil-1 AWG  
4.5 (40)  
4.0 (35)  
42 (375)  
3
1
2
3
1
2
3
1
2
3
1
2
3
JM60100-3CR  
JM60200-1CR  
JM60200-2CR  
JM60200-3CR  
JM60400-1CR  
JM60400-2CR  
JM60400-3CR  
JM60400-1MW22  
JM60400-2MW22  
JM60400-3MW22  
JM60600-1CR  
JM60600-2CR  
JM60600-3CR  
Cu 3/0-1 AWG  
110-200  
225-400  
450-600  
CVR-J-60200  
CVR-J-60400  
CVR-J-60600  
CVRI-J-60200  
CVRI-J-60400  
CVRI-RH-60600  
2-6 AWG; (2) Cu 2-6 AWG  
Cu 2-6 AWG  
31 (275)  
600kcmil  
57 (500)  
51 (450)  
500kcmil-4 AWG  
N/A  
(2) Cu 3/0 - 4 AWG  
(2) Al 3/0 - 4 AWG  
57 (500)  
34 (300)  
2 (2) 500kcmil-4 AWG  
N/A  
51 (450)  
*
Covers sold separately.  
** Open fuse indication requires 90 volts minimum and closed circuit to operate.  
*** Ratings for copper and aluminum conductors except where otherwise noted.  
Recommended Bussmann series fuses:  
Description  
Amps  
Data sheet no.  
Ultimate protection Low-Peak® LPJ time-  
70 to 600 1007  
up to 600 1026  
delay fuses  
Advanced protection Limitron™ JKS fast-  
acting fuses  
Optional see-through, snap-on  
Probe holes for easy testing  
Optional open fuse indication  
speeds troubleshooting  
cover for easy visual inspection  
without removing cover  
Lockout/tagout feature  
improves safety  
Finger grips on cover  
for easy removal  
Vent slots improve cooling*  
Standard phase barriers  
for additional safety  
Finger-safe wire entry  
with cutout tabs for larger  
wires on all versions  
Multiple mounting holes for  
each pole provide flexible,  
secure mounting  
Toolless interlocking modular design  
for easy point-of-use assembly  
Standard dual lugs on  
600A blocks and optional  
dual lugs on 400A blocks  
for easier wiring using  
two, smaller conductors.  
*No fuse derating necessary.  
Eaton.com/bussmannseries  
7
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Dimensions; 100A Class J block - in (mm)  
53  
2.1  
104  
4.1  
51  
102  
2.0  
4.0  
22 TYP  
.9  
29 TYP  
1.1  
1
TYP  
.04  
71  
8 TYP  
2.8  
.3  
29 TYP  
1.1  
JM60100-2CR  
JM60100-1CR  
138 TYP  
5.4  
13 TYP  
.5  
ALLEN KEY  
9/32" TYP  
77  
55 TYP  
3.0  
2.2  
35 TYP  
1.4  
37 TYP  
1.5  
51 TYP  
2.0  
155  
6.1  
153  
6.0  
CVR-J-60100-M  
(NON INDICATING)  
152  
6.0  
CVRI-J-60100-M  
(WITH INDICATION)  
JM60100-3CR  
REMOVE FOR  
WIRE LARGER  
THAN 6 AWG  
JM60100-1CR  
(SHOWN WITH COVER)  
8
Eaton.com/bussmannseries  
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Dimensions; 200A Class J block - in (mm)  
69 TYP  
2.7  
67 TYP  
2.6  
136  
5.4  
134  
5.3  
35 TYP  
1.4  
8
.3  
TYP  
32 TYP  
1.2  
172 TYP  
6.8  
9
.3  
TYP  
81 TYP  
32 TYP  
1.3  
3.2  
19 TYP  
.8  
JM60200-2CR  
JM60200-1CR  
ALLEN KEY  
3/8" TYP.  
97 TYP  
3.8  
75 TYP  
3.0  
45 TYP  
1.8  
67 TYP  
2.6  
46 TYP  
1.8  
203  
8.0  
200  
7.9  
186  
7.3  
JM60200-3CR  
CVR-J-60200-M  
(COVER NON-INDICATING)  
CVRI-J-60200-M  
(COVER WITH INDICATION)  
REMOVE FOR  
WIRES LARGER  
THAN 2 AWG  
JM60200-1CR  
(SHOWN WITH COVER)  
Eaton.com/bussmannseries  
9
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Dimensions; 400A Class J block - in (mm)  
91 TYP  
3.6  
88 TYP  
3.5  
50 TYP  
179  
7.1  
176  
6.9  
2.0  
38 TYP  
8
TYP  
1.5  
.3  
41 TYP  
1.6  
9 TYP  
.3  
201 TYP  
7.9  
JM60400-1CR  
19TYP  
.8  
JM60400-2CR  
90 TYP  
3.5  
ALLEN KEY  
1/2" TYP  
27 TYP  
1.1  
125 TYP  
4.9  
104 TYP  
4.1  
67 TYP  
2.6  
88 TYP  
3.5  
88 TYP  
3.5  
67 TYP  
2.6  
44 TYP  
1.7  
JM60400-2MW22  
268  
10.5  
JM60400-1MW22  
265  
10.4  
216  
8.5  
JM60400-3CR  
CVR-J-60400-M  
(COVER NON-INDICATING)  
CVRI-J-60400-M  
(COVER WITH INDICATION)  
REMOVE ONLY  
FOR DUAL LUG  
REMOVE FOR  
WIRES LARGER  
THAN 250KCMIL  
JM60400-1CR  
(SHOWN WITH COVER)  
10  
Eaton.com/bussmannseries  
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
Dimensions; 600A Class J block - in (mm)  
123 TYP  
4.8  
120 TYP  
4.7  
244  
9.6  
241  
9.5  
71 TYP  
2.8  
ALLEN KEY  
3/8" TYP  
8
TYP  
51 TYP  
2.0  
.3  
52 TYP  
2.1  
9
.3  
TYP  
234 TYP  
9.2  
100 TYP  
3.9  
JM60600-1CR  
JM60600-2CR  
19 TYP  
.8  
151 TYP  
5.9  
134 TYP  
5.3  
43 TYP  
1.7  
73 TYP  
2.9  
121 TYP  
4.8  
29 TYP  
1.1  
365  
14.4  
363  
14.3  
253  
10.0  
JM60600-3CR  
CVR-JM60600  
(COVER NON-INDICATING)  
CVRI-JM60600  
(COVER WITH INDICATION)  
REMOVE FOR  
WIRE LARGER  
THAN 250KCMIL  
JM60600-1CR  
(SHOWN WITH COVER)  
Eaton.com/bussmannseries  
11  
Class J modular ferrule and knifeblade fuse blocks  
Technical Data 10488  
Effective February 2016  
The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are  
by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the  
end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit  
distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once  
a product has been selected, it should be tested by the user in all possible applications.  
Eaton  
1000 Eaton Boulevard  
Cleveland, OH 44122  
For Eatons Bussmann series  
Eaton.com  
product information,  
call 1-855-287-7626 or visit:  
Eaton.com/bussmannseries  
Bussmann Division  
114 Old State Road  
Ellisville, MO 63021  
United States  
Eaton.com/bussmannseries  
Follow us on social media to get the  
latest product and support information.  
© 2016 Eaton  
All Rights Reserved  
Printed in USA  
Publication No. 10488 — BU-MC16XXX  
February 2016  
Eaton and Bussmann are valuable trademarks  
of Eaton in the U.S. and other countries. You  
are not permitted to use the Eaton trademarks  
without prior written consent of Eaton.  

相关型号:

JM60060-2MW12

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER

JM60060-2MW14

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER

JM60060-2MW24

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER

JM60060-3CHR

Class J modular ferrule and knifeblade fuse blocks
ETC

JM60060-3CR

Class J modular ferrule and knifeblade fuse blocks
ETC

JM60060-3MW12

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER

JM60060-3MW14

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER

JM60060-3MW24

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER

JM60100-1CR

Industrys fi rst modular fuse block simplifi es design and enhances safety
COOPER

JM60100-1MW14

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER

JM60100-2CR

Industrys fi rst modular fuse block simplifi es design and enhances safety
COOPER

JM60100-2MW14

Up to 400 A Class J ferrule and knifeblade power distribution fuse blocks
COOPER