SMALL SIZED
POWER RELAY
JZ-RELAYS
14
.551
FEATURES
22
.866
• Small sized flat type: 22×14×11.6 mm .866×.551×.457 inch
• High dielectric withstanding: 10,000 V surge in µs between coil and contact
• High electrical noise immunity
11.6
.457
• High sensitivity type available
• VDE,TÜV, SEMKO also approved
mm inch
SPECIFICATIONS
Contact
Characteristics
(at 25°C 77°F, 50% Relative humidity)
Standard
type
High
Standard
TV-5 High
Max. operating speed
Initial insulation resistance*1 Min. 100 MΩ at 500 V DC
20 cpm
Type
sensitivity type TV-5 type sensitivity type
Arrangement
1 Form A
Between open
contacts
750 Vrms for 1 min.
2,000 Vrms for 1 min.
Min. 10,000 V
Initial
Contact material
Silver alloy
breakdown
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
Between
contacts and coil
voltage*2
100 mΩ
5 A 125 V AC 3 A 125 V AC 8 A 125 V AC 8 A 125 V AC
5 A 30 V DC 3 A 30 V DC 5 A 30 V DC 5 A 30 V DC
Surge voltage between
contact and coil*3
Nominal switching capacity
Rating
(resistive)
Max. switching power
150 W, 750 VA 90 W, 500 VA 150 W, 1,250 VA 150 W, 1,000 VA
Operate time*4
(at nominal voltage)
Release time*4
(without diode)
Approx. 4 ms
Max. switching voltage
250 V AC, 110 V DC (0.3 A)
Max. switching current
5 A
105
3 A
8 A
Approx. 2 ms
Mechanical (at 180 cpm)
Expected
life (min.
5 × 106
(at nominal voltage)
2 ×105
105
5 ×104
Temperature rise
(ambient temperature at
70°C)
Max. 45°C
at max. switching current
Electrical
(at 20 cpm)
(at nominal (3 A 125 V AC) (at nominal (8 A 125 V AC)
operating
capacity)
105
operating
capacity)
105
operations)
(3 A 30 V DC)
(5 A 30 V DC)
Functional*5
Min. 98 m/s2 {10 G}
Min. 980 m/s2 {100 G}
98 m/s2 {10 G}, 10 to 55 Hz at
double amplitude of 1.6 mm
Shock
Coil (at 20°C 68°F)
Standard type
Destructive*6
Functional*7
resistance
Nominal operating power
Nominal operating power
400 mW
200 mW
High sensitivity type
Vibration
117.6 m/s2 {12 G}, 10 to 55 Hz
at double amplitude of 2 mm
resistance
Remarks
Destructive
* Specifications will vary with foreign standards certification ratings.
*1 Measurement at same location as "Initial breakdown voltage" section
*2 Detection current: 10mA
Conditions for operation, Ambient
–40°C to +70°C
–40°F to +158°F
transport and storage*8
(Not freezing and condens-
ing at low temperature)
temp.
*3 Wave is standard shock voltage of ±1.2 × 50µs according to JEC-212-1981
*4 Excluding contact bounce time
Humidity
5 to 85% R.H.
*5 Half-wave pulse of sine wave: 11ms; detection time: 10µs
*6 Half-wave pulse of sine wave: 6ms
Unit weight
Approx. 7 g .25 oz
*7 Detection time: 10µs
*8 Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 24).
TYPICAL APPLICATIONS ORDERING INFORMATION
• Microwave oven (fan, inside lamp)
Ex. JZ
1a
F
S
9 V
TV
• Machineries which need electrical
noise resistance and surge resistance,
(Ex. hot-water heater)
Contact
Protective
arrangement construction
Coil voltage
(DC)
Type classification
Type classification
1a: 1 Form A F: Flux-resistant Nil: Standard
5, 6, 9, 12, Nil: UL/CSA/VDE
type
recognized type
(400 mW)
S: High sensitivity
(200 mW)
18, 24 V
TV: TV-5 rated type
Note: Standard packing Carton: 100 pcs. Case: 500 pcs.
UL/CSA, TV-5 (only for TV type) approved type is standard.
62
JZ
TYPES AND COIL DATA (at 20°C 68°F)
1) Standard type
Drop-out
voltage,
V DC (min.)
Nominal
operating
current, mA
Nominal
operating
power, mW
Max. allowable
voltage, at
70°C, V DC
Nominal voltage, Pick-up voltage,
Coil resistance,
Part No.
V DC
V DC (max.)
Ω (±10%)
JZ1aF-5V
JZ1aF-6V
JZ1aF-9V
JZ1aF-12V
JZ1aF-18V
JZ1aF-24V
5
6
3.5
4.2
0.25
0.3
62.5
90
80
67
45
33
22
17
400
400
400
400
400
400
5.5
6.6
9
6.3
0.45
0.6
202
9.9
12
18
24
8.4
360
13.2
19.8
26.4
12.6
16.8
0.9
810
1.2
1,440
2) High sensitivity type
Drop-out
voltage,
V DC (min.)
Nominal
operating
current, mA
Nominal
operating
power, mW
Max. allowable
voltage, at
70°C, V DC
Nominal voltage, Pick-up voltage,
Coil resistance,
Part No.
V DC
V DC (max.)
Ω (±10%)
JZ1aFS-5V
JZ1aFS-6V
JZ1aFS-9V
JZ1aFS-12V
JZ1aFS-18V
JZ1aFS-24V
5
6
4
0.25
0.3
125
180
40
33
22
17
11
8.3
200
200
200
200
200
200
6.5
7.8
4.8
7.2
9.6
14.4
19.2
9
0.45
0.6
405
11.7
15.6
23.4
31.2
12
18
24
720
0.9
1,620
2,880
1.2
mm inch
DIMENSIONS
PC board pattern (Copper-side view)
22
14
.866
.551
2-1.3 dia.
2-.051 dia.
2-0.9 dia.
2-.035 dia.
15.24
.600
11.2
.441
4.3
7.62
.300
10.16
.400
.169
0.4
.016
2.54
17.78
.700
.100
15.24
.600
5.08
.200
Tolerance: ±0.1±.004
COM
3
4
2
1
7.62
.300
10.16
.400
N.O.
2.11
.083
General tolerance: ±0.3 ± .012
REFERENCE DATA
• Not TV-5 rated type
1. Max. switching power
(AC resistive load)
2.-(1) Operate/Release time
(Standard type)
2.-(2) Operate/Release time
(High sensitivity type)
100
10
10
8
8
Standard type
10
6
6
5
Operate time
Operate time
4
4
High sensitivity type
1
Max.
Max.
–
x
Max.
Max.
– –
Min.
x x
Min.
–
x
Min.
2
2
Min.
Release time
Release time
0
0
10
100 250 1,000
AC voltage, V
80
100
120
80
100
120
Coil applied voltage, %V
Coil applied voltage, %V
63
JZ
3. Coil temperature rise
4.-(1) Ambient temperature vs. coil applied
voltage (Standard type)
Contact current: 1 A
4.-(2) Ambient temperature vs. coil applied
voltage (High sensitivity type)
Contact current: 1 A
Point measured: Coil inside
Contact current: 3 A
500
Allowable ambient temperature
against % coil voltages
(max. inside the coil
temperature set as
115°C 239°F)
160
140
120
100
80
30°C
(Standard type)
400
80
60
Allowable ambient temperature
against % coil voltages
30°C
(High sensitivity type)
300
200
100
0
(max. inside the coil temperature
70°C
set as 115°C 239°F)
(Standard
type)
40
20
0
70°C
(High sensitivity
type)
Pick-up voltage
60
Pick-up voltage
0
20
40
60
80
20
40
60
80
70 80 100 120 140 160 180
Coil applied voltage, %V
Ambient temperature, °C
Ambient temperature, °C
5. Electrical life (load test: fan motor, turntable motor and inside lamp of microwave oven)
Tested sample: JZ1aFS-24V, 6 pcs.
Load: 100 V AC 0.5 A; Rush current: 2.5 A
Operation frequency: 4 times/min.
(ON:OFF = 3s:12s)
Change of pick-up and drop-out voltage
Change of contact resistance
With coil diode protection
Ambient temperature: 70°C 158°F
80
60
40
20
0
80
Circuit
Pick-up voltage
60
Max.
–
x
30 W
Min.
Max.
motor
(fan
motor)
100 V
AC
20 W
lamp
(Inside lamp)
3 W
–
40
20
0
x
M
M
motor
(turntable
motor)
Min.
Drop-out voltage
Max.
–
x
Min.
5
10
15
20
5
10
15
20
No. of operations, ×104
No. of operations, ×104
6. Noise resistance
Noise wave form
Output wave form
Tested sample: JZ1aFS-24V
(Applied voltage wave form to the contact)
(Output wave form on the coil side)
10,000
9,500
50
Circuit
Surge
simulator
Digital
memory
8,000
6,000
4,000
2,000
40
30
20
10
Contact
Coil
70Ω
0
1
2
3
4
0
1
2
3
4
Time, µs
Time, µs
• TV-5 rated type
1. Max. switching power
2-(1). Operate/Release time
(Standard type)
2-(2). Operate/Release time
(High sensitivity type)
Sample: JZ1aF-12V-TV
Sample: JZ1aFS-12V-TV
8
10
100
8
6
AC resistive load
10
1
6
4
4
2
0
Max.
Operate time
–
x
Max.
Max.
–
Min.
x
Min.
–
x
2
0
Min.
Release time
10
100 250
1,000
80
100
120 130
80
100 120 140 160 180
Coil applied voltage, %V
Contact voltage, V
Coil applied voltage, %V
64
JZ
3-(1). Coil temperature rise (Standard type)
3-(2). Coil temperature rise (High sensitivity type)
Sample: JZ1aF-12V-TV
Point measured: Coil inside
Contact current: 8 A
Sample: JZ1aFS-12V-TV
Point measured: Coil inside
Contact current: 5 A
80
100
80
60
30°C
60
30°C
40
20
0
70°C
70°C
40
20
0
80 90 100 110 120 130
Coil applied voltage, %V
80 100 120 140 160 180
Coil applied voltage, %V
4-(1). Ambient temperature vs. coil applied
voltage (Standard type)
4-(2). Ambient temperature vs. coil applied
voltage (High sensitivity type)
Sample: JZ1aF-12V-TV
Sample: JZ1aFS-12V-TV
Contact current: 5 A
500
180
160
0 A
400
Allowable ambient
temperature against
% coil voltage
5 A
Allowable ambient
300
140
(max. inside the coil
temperature against
temterature set as
115°C 239°F)
% coil voltage
120
100
80
(max. inside the coil
temterature set as
115°C 239°F)
200
100
0
Pick-up voltage
with a hot-start
condition of 100%V
Pick-up voltage
with a hot-start
condition of 100%V
5 A
0 A
Pick-up voltage
Pick-up voltage
60
0
20
40
60
80
20
40
60
80
Ambient temperature, °C
Ambient temperature, °C
5-(1). Electrical life test (TV-5)
Change of pick-up and drop-out voltage
Change of contact resistance
Tested sample: JZ1aF-12V-TV, 6 pcs.
UL Lamp load test
50
80
Pick-up voltage
Max.
Overload
Endurance
AC 120 V
–
x
40
30
20
10
0
Min.
Voltage
AC 120 V
60
40
Switching
frequency
60 Hz
60 Hz
Inrush: 111 A; Inrush: 78 A;
Steady: 7.5 A Steady: 5.0 A
Current
Drop-out voltage
Max.
10 cpm
(ON:OFF =
1s:5s)
10 cpm
(ON:OFF =
1s:5s)
–
x
20
0
Max.
Operating
speed
–
x
Min.
Min.
No. of
operations
50 ope.
25,000 ope.
2.5
No. of operations
2.5
No. of operations
5-(2). Electrical life test (Condenser load)
Change of pick-up and drop-out voltage
Change of contact resistance
Tested sample: JZ1aF-12V-TV, 6 pcs.
Load: DC 17 V 6.4 A, Inrush max. 139 A
Operating speed: 20 cpm
80
50
40
30
20
10
0
(ON:OFF = 1 s:2 s)
Pick-up voltage
Max.
Ambient temperature: 27°C 81°F
60
40
–
x
Circuit:
Min.
Changing coil
12 mΩ 200 µH
Mis-contacting
DC
17 V
detection
Contact welding
detection
20
0
16000
µH
Drop-out voltage
2.7 Ω
Max.
Max.
–
x
–
x
Min.
Min.
10
No. of operations, ×104
10
No. of operations
65
JZ
5-(3). Electrical life test (TV power source)
Change of pick-up and drop-out voltage
Change of contact resistance
Tested sample: JZ1aF-12V-TV, 10 pcs.
Load: AC 100 V TV power source
Inrush: 100 A max.; Steady: 5.0 A
Operating speed: 20 cpm
(ON:OFF = 1 s:2 s)
Ambient temperature: 40°C 104°F95% R.H.
80
50
Pick-up voltage
40
30
20
10
0
Max.
60
40
–
x
Circuit:
Min.
Mis-contacting
20
0
PC
board
Drop-out voltage
AC
100 V
detection
Max.
Max.
–
x
Contact welding
detection
–
x
Min.
Min.
40°C 95%R.H.
10
No. of operations, ×104
10
No. of operations, ×104
For Cautions for Use, see Relay Technical Information (Page 11 to 39).
66
相关型号:
©2020 ICPDF网 联系我们和版权申明