LZZ42 [ETC]

Installation and adjusting instructions LZ metal-enclosed switches; 安装和调整说明LZ金属封闭开关
LZZ42
型号: LZZ42
厂家: ETC    ETC
描述:

Installation and adjusting instructions LZ metal-enclosed switches
安装和调整说明LZ金属封闭开关

开关
文件: 总2页 (文件大小:277K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Sensing & Control  
PK 88142  
a Honeywell Division  
MODULAR PARTS  
Installation and adjusting instructions  
LZ metal-enclosed switches  
complete switch = operating head + base receptacle + switch body  
PK 88142  
Complete Switch  
Description  
Operating Head Only  
LZA1  
LZC1  
LZD1  
LZV1  
LZE1  
LZF1  
LZG1  
LZW1  
LZH1  
LZL1-6C  
Side Rotary  
Top Plain Plunger  
Top Roller Plunger, roller parallel to mounting surface  
Adjustable Top Plunger  
Side Plain Plunger  
Side Roller Plunger, roller parallel to mounting surface  
Side Roller Plunger, roller perpendicular to mounting surface  
Adjustable Side Plunger  
Side Palm Plunger  
Side Lever with lever bracket  
LZZ1A  
LZZ1C  
LZZ1D  
LZZ1V  
MOUNTING  
LZ may be mounted without unplugging the  
body from the base receptacle. Use two M5 or  
#10 screws that are at least 32mm (1.25 in.)  
long. A third mounting screw may be used by  
removing the knockout in the lower right  
corner. Refer to Figure 1.  
LZZ1E  
LZZ1F  
LZZ1G  
LZZ1W  
LZZ1H  
LZZ1M-6C  
REPLACEMENT LEVERS FOR  
SIDE ROTARY  
WIRING  
Up to 3mm or AWG12 wire may be used for  
wiring to the self-lifting pressure plate-type  
screw terminals. Maximum width of spade  
connectors or diameter of ring connectors is  
8mm (.312 in.). A ground terminal, which is  
colored green for easy identification, also has  
self-lifting pressure plate-type construction  
(refer to Figure 1.).  
Description  
Catalog Listing  
To order replacement levers,  
order the same part number as  
that which is metal stamped on  
either the lever or lever hub. For  
other variations of levers, refer  
to Heavy Duty LS in Catalog 40.  
Body with basic switch (Buna-N seal)  
LZZ21  
LZZ22  
LZZ41  
LZZ42  
LZZ43  
Body with basic switch (Fluorocarbon seal)  
Base Receptacle  
Adapter Plate  
Lever bracket (without lever)  
Lever arm for above  
Nylon roller  
LZZ56C  
LZZ56D  
LZZ44  
LZZ57B  
LZZ57M  
Steel roller  
Boot for plungers  
Plastic wobble stick  
Spring wire wobble stick  
1¼ inch buttons  
Black  
After wiring, securely tighten the captive  
screws in the plug-in unit for effective seal-  
ing. Also plug conduit opening with sealant to  
ensure proper sealing.  
PWMZ22  
PWMZ23  
PWMZ25  
Red  
Yellow  
1½ inch buttons  
Black  
ADJUSTMENTINSTRUCTIONS  
Actuator Head  
PWMZ32  
PWMZ33  
PWMZ35  
Red  
Yellow  
All LZ actuator heads can be positioned in  
any of four directions. Loosen the four cap-  
tive head screws, place the head in the desired  
position, and securely tighten the screws.  
Refer to Figure 2.  
MICRO SWITCH WORLDWIDE SALES AND  
SERVICE  
MICRO SWITCH serves its customer through  
a worldwide network of sales offices and dis-  
tributors. For application assistance, pricing  
or name of nearest Authorized Distributor,  
contact a nearby MICRO SWITCH sales  
office. Or, write MICRO SWITCH, Freeport,  
Illinois 61032; phone 815/235-6600.  
Top Roller Plunger  
Position the top roller plunger in the desired  
plane by locating the head as outlined under  
Actuator Head.  
POSITIONING LEVER OF ROTARY TYPE  
The lever on rotary switches is adjustable to  
any angular position through 360°. Levers  
are reversible, they can also be shifted axially  
through approximately 3,2mm (.125 in.) on  
the shaft. To adjust, or to assemble to switch,  
loosen the screw with a 9/64 hexagon key  
wrench, move the lever to the desired posi-  
tion, and securely tighten the screw. The  
lever should be tightened until the "teller tab"  
can no longer be moved by hand. Hex key  
wrenches are provided in adjusting tool set  
LSZ4005.  
While we provide application assistance on  
MICRO SWITCH products, personally and  
through our literature, it is up to the customer  
to determine the suitability of the product in  
his application.  
PK 8814 2 880 PRINTED IN USA  
PK 88142  
PK 88142  
SIDE ROTARY TYPE  
SIDE LEVER BRACKET TYPE  
POSITIONING THE SIDE LEVER BRACKET  
CHANGING ACTUATION DIRECTION  
REVERSING THE ROLLER LEVER ARM  
ON ROTARY TYPE  
The side lever bracket can be placed in any of  
four positions. When combined with the four  
possible head positions, this makes for 16  
possible positions for this type. Remove the  
lever with a 5/32 inch hexagon key wrench.  
Loosen three captive bracket screws, place  
the bracket in the desired position, and  
securely tighten the screws (refer to Figure  
Roller arms may be reversed to face the roller  
to the inside or outside of the arm (refer to  
Figure 7). It is recommended that the lever of  
side lever bracket forms be adjusted within  
the parameters shown in Figure 7. Use a 5/32  
hexagon key wrench.  
Rotary switches may be adjusted to operate  
clockwise, counterclockwise, or both. Instruc-  
tions are cast into the head (Figure 4). Follow  
these steps:  
1. Loosen the four captive head screws and  
remove head from switch housing.  
2. Switches are assembled with the plunger  
set for both way operation. (See drawing  
Figure 4.)  
6).  
Both way actuation: plunger point in  
twelve o'clock position (towards the  
actuator).  
To change mode of operation pull the  
spring loaded plunger outward with pli-  
ers to the stop. With plunger, pulled turn  
the point in the direction of operation  
required.  
Clockwise actuation only: turn clock-  
wise to three o'clock position.  
Counterclockwise actuation only: turn  
counterclockwise to nine o'clock posi-  
tion.  
3. Release plunger, it will snap into the head  
into a locked position.  
4. Replace operating head on switch hous-  
ing and securely tighten screws.  
5 . Check for desired operation by actuating  
switch and listening for "click".  
HEX HEAD SCREWS  
If you prefer to loosen and tighten the lever  
with a pliers or a screwdriver, a packet of 50  
hex head screws, with screwdriver slot, is  
a v a i l a b l e s e p a r a t e l y ( c a t a l o g l i s t i n g  
15PA164-LS) to replace the allen head screw  
furnished with the lever.  
WOBBLE STICK ACTUATOR TYPE  
REPLACING THE WOBBLE STICK  
To remove a wobble stick, firmly grasp the  
wobble stick with a pair of pliers at the base of  
the wobble stick. (Figure 8, View A.) Turn the  
wobble stick counterclockwise to unscrew it.  
Adjusting tool set LSZ4005 consists of one  
special 3/32 inch open wrench and necessary  
hexagon key wrenches to adjust all types of  
levers.  
To attach a wobble stick, start threading the  
actuator to the head by hand. Then firmly  
grasp the wobble stick with a pair of pliers as  
shown in Figure 8, View B. Turn the wobble  
stick clockwise to within 1/8 inch of the end of  
the threads.  

相关型号:

LZZ43

Installation and adjusting instructions LZ metal-enclosed switches
ETC

LZZ44

Installation and adjusting instructions LZ metal-enclosed switches
ETC

LZZ56C

Installation and adjusting instructions LZ metal-enclosed switches
ETC

LZZ56D

Installation and adjusting instructions LZ metal-enclosed switches
ETC

LZZ57B

Installation and adjusting instructions LZ metal-enclosed switches
ETC

LZZ57M

Installation and adjusting instructions LZ metal-enclosed switches
ETC

M-0402K1002FST1

Fixed Resistor, Metal Glaze/thick Film, 0.1W, 10000ohm, 25V, 1% +/-Tol, -100,100ppm/Cel, 0402
VISHAY

M-0402K10R0FST1

RES SMD 10 OHM 1% 1/10W 0402
VISHAY

M-0402K1200GGBS

Fixed Resistor, Metal Glaze/thick Film, 0.1W, 120ohm, 25V, 2% +/-Tol, -100,100ppm/Cel, 0402
VISHAY

M-0402K1600GGBS

Fixed Resistor, Metal Glaze/thick Film, 0.1W, 160ohm, 25V, 2% +/-Tol, -100,100ppm/Cel, 0402
VISHAY

M-0402K1603JST0

Fixed Resistor, Metal Glaze/thick Film, 0.1W, 160000ohm, 25V, 5% +/-Tol, -100,100ppm/Cel, 0402
VISHAY

M-0402K3603GGTS

Fixed Resistor, Metal Glaze/thick Film, 0.1W, 360000ohm, 25V, 2% +/-Tol, -100,100ppm/Cel, 0402
VISHAY