Hi-Rel DC/DC CONVERTER  
MGDM-10 : 10W POWER  
Hi-Rel  
Grade  
Single, Bi & Triple Outputs  
Metallic Case - 1.500 VDC Isolation  
• 28Vdc input compliant with MIL-STD-704 D/E  
• Low profile : 0,33 “ (8.5mm)  
• Nominal power of 10 W without derating  
• Wide temperature range : -40°C/+105°C case  
• High efficiency up to 83 %  
• Soft start  
1-General  
• Galvanic isolation 1.500 VDC  
• Integrated LC EMI filter  
The modules include a soft-start, an input  
undervoltage lock-out, a permanent short circuit  
protection and an output overvoltage protection  
to ensure efficient module protections.  
The soft-start allows current limitation and  
eliminates inrush current during start-up. The short  
circuit protection completely protects the module  
against short-circuits of any duration by a shut-  
down and restores to normal when the overload is  
removed.  
The design has been carried out with surface mount  
components and is manufactured in a fully  
automated process to guarantee high quality. Each  
module is tested and burned in with a GAIA  
Converter automated test equipment before and  
after encapsulation.The modules are potted with  
an excellent thermal conductive compound and  
packaged in a metallic case to ensure the module’s  
integrity under high temperature conditions.  
The MGDM-10 series is a full family of high perfor-  
mance DC/DC low profile power modules designed  
for aerospace, military and high-end industrial ap-  
plications. These modules use a high frequency  
fixed switching technic at 480 KHz providing ex-  
cellent reliability, low noise characteristics, high  
power density and a low profile package. Standard  
models are available with nominal input voltages  
as 5, 12 or 28 volts in range of 4,5-5,5 9-36 or 16-  
40 volts. The series include single bi and triple  
output voltage choices of 3,3, 5, 12, 15, +/-5, +/  
-12, +/-15 or +/-24 volts. No external heatsink is  
required for the MGDM-10 series to supply 10W  
output power over the case temperature range of  
-40°C up to 105°C.  
• Permanent short circuit protection  
• Parallel operation master/slave  
• No optocoupler for high reliability  
4
All the modules are designed with LC network filters  
to minimize reflected input current ripple and out-  
put voltage ripple.  
2-Product Selection  
Master converter :  
Single output model : MGDS-10-  
(/T) and/or (/S)  
(/T) and/or (/S)  
(/T) and/or (/S)  
Bi output model  
: MGDB-10-  
Triple output model : MGDT-10-  
Slave converter :  
Single output model : MGDE-10-  
(/T) and/or (/S)  
(/T) : option for -55°C start up operating temperature.  
(/S) : option for screening and serialization  
Input Voltage Range  
Output  
Permanent  
Transient  
B : 3.3 VDC  
C : 5 VDC or +/-5VDC  
E : 12 VDC or +/-12VDC  
F : 15 VDC or +/-15VDC  
CE : 5 VDC and +/-12 VDC  
CF : 5 VDC and +/-15 VDC  
I : +/-24 VDC  
C
:
4,5-5,5 VDC  
n/a  
H : 9-36 VDC  
J : 16-40 VDC  
40 VDC/100 ms*  
50 VDC/100 ms*  
* Consult factory for details  
REDEFINING THE SOURCE OF POWER  
For locations, phone, fax, E-Mail see back cover  
Gaia Converter FC97-010.08/06 Revision P  
©
Hi-Rel  
Grade  
MGDM-10 Series  
2- Product Selection (continued)  
Input range  
Output  
Current  
Reference  
Options  
4,5-5,5 VDC  
4,5-5,5 VDC  
4,5-5,5 VDC  
4,5-5,5 VDC  
4,5-5,5 VDC  
4,5-5,5 VDC  
4,5-5,5 VDC  
3,3 VDC  
5 VDC  
12 VDC  
2 A  
2 A  
0,800 A  
0,650 A  
+/- 1 A  
MGDS-10-C-B  
MGDS-10-C-C  
MGDS-10-C-E  
MGDS-10-C-F  
MGDB-10-C-C  
MGDB-10-C-E  
MGDB-10-C-F  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
15 VDC  
+/- 5 VDC  
+/- 12 VDC  
+/- 15 VDC  
+/- 0,400 A  
+/- 0,330 A  
9-36 VDC  
9-36 VDC  
9-36 VDC  
9-36 VDC  
9-36 VDC  
9-36 VDC  
9-36 VDC  
9-36 VDC  
9-36 VDC  
3,3 VDC  
5 VDC  
12 VDC  
2 A  
2 A  
0,800 A  
0,650 A  
+/- 1 A  
MGDS-10-H-B  
MGDS-10-H-C  
MGDS-10-H-E  
MGDS-10-H-F  
MGDB-10-H-C  
MGDB-10-H-E  
MGDB-10-H-F  
MGDT-10-H-CE  
MGDT-10-H-CF  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
15 VDC  
+/- 5 VDC  
+/- 12 VDC  
+/- 15 VDC  
5 & +/- 12 VDC  
5 & +/- 15 VDC  
+/- 0,400 A  
+/- 0,330 A  
1 A & +/-0,20 A  
1 A & +/- 0,15 A  
16-40 VDC  
16-40 VDC  
16-40 VDC  
16-40 VDC  
16-40 VDC  
16-40 VDC  
16-40 VDC  
16-40 VDC  
16-40 VDC  
16-40 VDC  
3,3 VDC  
5 VDC  
12 VDC  
2 A  
2 A  
0,800 A  
0,650 A  
+/- 1 A  
MGDS-10-J-B  
MGDS-10-J-C  
MGDS-10-J-E  
MGDS-10-J-F  
MGDB-10-J-C  
MGDB-10-J-E  
MGDB-10-J-F  
MGDB-10-J-I  
MGDT-10-J-CE  
MGDT-10-J-CF  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
/T , /S  
15 VDC  
+/- 5 VDC  
+/- 12 VDC  
+/- 15 VDC  
+/- 24 VDC  
5 & +/- 12 VDC  
5 & +/- 15 VDC  
+/- 0,400 A  
+/- 0,330 A  
+/- 0,200 A  
1 A & +/-0,20 A  
1 A & +/- 0,15 A  
4
Converter Selection Chart  
M G D S - 10 - H - C / T  
Number of Outputs :  
S : single output  
B : bi ouput  
T : triple output  
Input voltage range :  
C : 4,5-5,5 VDC  
H : 9-36 VDC  
J : 16-40 VDC  
Output voltage :  
See table page 1  
Option :  
/T : -55°C start up operation  
/S  
:
screening and  
(consult  
serialization  
application note «screening  
grades»)  
2
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
3- Electrical Specifications  
Data are valid at +25°C, unless otherwise specified.  
Single Output MGDS-10  
Limit or  
typical  
Parameter  
Conditions  
Units  
10-C  
10 - H  
10 - J  
Input  
Nominal input voltage  
Full temperature range  
Full temperature range  
Nominal  
VDC  
VDC  
5
20  
28  
Permanent input  
voltage range (Ui)  
Min. - Max.  
4,5-5,5  
9-36  
16-40  
Extended permanent input Full temperature range  
Min. - Max.  
Maximum  
VDC  
/
/
/
16-45  
voltage range  
(Consult factory)  
Transient input voltage  
Full load (Consult factory)  
VDC/S  
40/0,1  
50/0,1  
Undervoltage lock-out  
(UVLO)  
Minimum  
Maximum  
VDC  
VDC  
4
4,3  
7
8,5  
12  
15  
turn-on/turn-off threshold  
Ui nominal  
Start up time  
Nominal output  
Full load : resistive  
Maximum  
ms  
30  
30  
30  
Ui nominal, full load at  
switching freq. BW = 20MHz  
Reflected ripple current  
Maximum  
Maximum  
Maximum  
mApp  
mA  
50  
50  
50  
50  
30  
30  
30  
30  
30  
Input current in short  
circuit mode (Average)  
Ui nominal  
Short-circuit  
Ui nominal  
No load  
No load input current  
Output  
mA  
Nominal  
Nominal  
Nominal  
Nominal  
VDC  
VDC  
VDC  
VDC  
3,3  
5
12  
15  
3,3  
5
12  
15  
3,3  
5
12  
15  
Full temperature range  
Ui min. to max.  
75% load  
Output voltage *  
4
Ambient temperature : +25°c  
Ui nominal, 75% load  
Set Point accuracy  
Output power  
Maximum  
Maximum  
%
W
+/- 2  
10  
+/- 2  
10  
+/- 2  
10  
Full temperature range  
Ui min. to max.  
Output current**  
3,3V output  
5V output  
12V output  
15V outputt  
Maximum  
Maximum  
Maximum  
Maximum  
A
A
A
A
2
2
0,80  
0,65  
2
2
0,80  
0,65  
2
2
0,80  
0,65  
Full temperature range  
Ui min. to max.  
Ripple output voltage***  
3,3V and 5V output  
12V output  
Ui nominal  
Full load  
BW = 20MHz  
Maximum  
Maximum  
Maximum  
mVpp  
mVpp  
mVpp  
40  
50  
60  
40  
50  
60  
40  
50  
60  
15V output  
Ui min. to max.  
Full load  
Line regulation  
Load regulation ****  
Efficiency  
Maximum  
Maximum  
Typical  
%
%
%
+/- 1  
+/- 1  
+/- 2,5  
+/- 1  
Ui nominal  
25% to full load  
+/- 2,5  
+/- 2,5  
Ui nominal  
Full load  
See on page 6  
Maximum admissible  
Capacity load  
3,3V and 5V output  
12V and 15V output  
Ui nominal  
Full load  
Per output  
Maximum  
Maximum  
µF  
µF  
1.000  
330  
1.000  
330  
1.000  
330  
Note * : For proper operation the MGDM-10 module requires to install a 22µF chemical or tantalum capacitance accross output terminals.  
Note ** : For 9-36V input range, the current is derated at 80% at 9V and increases linearly to full current at 12V.  
Note*** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered.  
This noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the  
pin Gout of the converter. This capacitor should be layed-out as close as possible from the converter.  
Note**** : For load regulation characteristics from 0% to full load, please see page 6.  
3
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
3- Electrical Characteristics (continued)  
Data are valid at +25°C, unless otherwise specified.  
Bi Output MGDB-10  
Limit or  
typical  
Parameter  
Conditions  
Units  
10-C  
10 - H  
10 - J  
Input  
Nominal input voltage  
Full temperature range  
Full temperature range  
Nominal  
VDC  
VDC  
5
20  
28  
Permanent input  
voltage range (Ui)  
Min. - Max.  
4,5-5,5  
9-36  
16-40  
Extended permanent input Full temperature range  
Min. - Max.  
Maximum  
VDC  
/
/
/
16-45  
voltage range  
(Consult factory)  
Transient input voltage  
Full load (Consult factory)  
VDC/S  
40/0,1  
50/0,1  
Undervoltage lock-out  
(UVLO)  
Minimum  
Maximum  
VDC  
VDC  
4
4,3  
7
8,5  
12  
15  
Turn-on/turn-off threshold  
Ui nominal  
Start up time  
Nominal output  
Full load : resistive  
Maximum  
ms  
30  
30  
30  
Ui nominal, full load at  
switching freq. BW = 20MHz  
Reflected ripple current  
Maximum  
Maximum  
Maximum  
mApp  
mA  
50  
50  
50  
50  
30  
30  
30  
30  
30  
Input current in short  
circuit mode (Average)  
Ui nominal  
Short-circuit  
Ui nominal  
No load  
No load input current  
Output  
mA  
Nominal  
Nominal  
Nominal  
Nominal  
VDC  
VDC  
VDC  
VDC  
+/- 5  
+/- 12  
+/- 15  
/
+/- 5  
+/- 12  
+/- 15  
/
+/- 5  
+/- 12  
+/- 15  
+/- 24  
Full temperature range  
Ui min. to max.  
75% load  
Output voltage *  
4
Ambient temperature : +25°c  
Ui nominal, 75% load  
Set Point accuracy  
Output power  
Maximum  
Maximum  
%
W
+/- 2  
+/- 5  
+/- 2  
+/- 5  
+/- 2  
+/- 5  
Full temperature range  
Ui min. to max.  
Output current**  
5V output  
12V output  
15V output  
24V output  
Maximum  
Maximum  
Maximum  
Maximum  
A
A
A
A
+/- 1  
+/- 0,40  
+/- 0,33  
/
+/- 1  
+/-0, 40  
+/- 0,33  
/
+/- 1  
Full temperature range  
Ui min. to max.  
+/-0, 40  
+/- 0,33  
+/-0,20  
Ripple output voltage***  
5V output  
12V output  
Ui nominal  
Full load  
BW = 20MHz  
Maximum  
Maximum  
Maximum  
mVpp  
mVpp  
mVpp  
40  
50  
60  
40  
50  
60  
40  
50  
60  
15V and 24 output  
Ui min. to max.  
Full load  
Line regulation  
Maximum  
Maximum  
%
%
+/- 1  
+/- 1  
+/- 1  
Ui nominal  
25% to full load  
Load regulation ****  
+/- 2,5  
+/- 2,5  
+/- 2,5  
Ui nominal  
+ Vout nominal load  
- Vout from 25% to full load  
Cross load output  
regulation  
Maximum  
Typical  
%
%
+/- 0,5  
+/- 0,5  
+/- 0,5  
Ui nominal  
Full load  
Efficiency  
See on page 6  
Maximum admissible  
Capacity load  
5V output  
Ui nominal  
Full load  
Per output  
Maximum  
Maximum  
µF  
µF  
470  
100  
470  
100  
470  
100  
12V, 15V and 24V output  
Note * : For proper operation the MGDM-10 module requires to install a 22µF chemical or tantalum capacitance accross output terminals.  
Note ** : For 9-36V input range, the current is derated at 80% at 9V and increases linearly to full current at 12V.  
Note*** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered.  
This noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the  
pin Gout of the converter. This capacitor should be layed-out as close as possible from the converter.  
Note**** : For load regulation characteristics from 0% to full load, please see page 6.  
4
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
3- Electrical Characteristics (continued)  
Data are valid at +25°C, unless otherwise specified.  
Tri Output MGDT-10  
Limit or  
typical  
Parameter  
Conditions  
Units  
10 - H  
10 - J  
Input  
Nominal input voltage  
Full temperature range  
Full temperature range  
Nominal  
VDC  
VDC  
20  
28  
Permanent input  
voltage range (Ui)  
Min. - Max.  
9-36  
16-40  
Extended permanent input Full temperature range  
Min. - Max.  
Maximum  
VDC  
/
16-45  
voltage range  
(Consult factory)  
Transient input voltage  
Full load  
VDC/S  
40/0,1  
50/0,1  
Undervoltage lock-out  
(UVLO)  
Minimum  
Maximum  
VDC  
VDC  
7
8,5  
12  
15  
Turn-on/turn-off threshold  
Ui nominal  
Start up time  
Nominal output  
Full load : resistive  
Maximum  
ms  
30  
30  
Ui nominal, full load at  
switching freq. BW = 20MHz  
Reflected ripple current  
Maximum  
Maximum  
Maximum  
mApp  
mA  
50  
30  
30  
30  
30  
30  
Input current in short  
circuit mode (Average)  
Ui nominal  
Short-circuit  
Ui nominal  
No load  
No load input current  
Output  
mA  
Full temperature range  
Ui min. to max.  
75% load  
Nominal  
Nominal  
VDC  
VDC  
5 & +/- 12  
5 & +/- 15  
5 & +/- 12  
5 & +/- 15  
Output voltage *  
4
Ambient temperature : +25°c  
Ui nominal, 75% load  
Set Point accuracy  
Output power  
Maximum  
Maximum  
%
W
+/- 2  
+/- 2  
Full temperature range  
Ui min. to max.  
5 & +/- 2,5  
5 & +/- 2,5  
Output current **  
5 & +/- 12V output  
5 & +/- 15V output  
Full temperature range  
Ui min. to max.  
Maximum  
Maximum  
A
A
1 & +/- 0,20  
1 & +/- 0,15  
1 & +/- 0,20  
1 & +/- 0,15  
Ripple output voltage ***  
5V output  
12V output  
Ui nominal  
Full load  
BW = 20MHz  
Maximum  
Maximum  
Maximum  
mVpp  
mVpp  
mVpp  
40  
50  
60  
40  
50  
60  
15V output  
Ui min. to max.  
Full load  
Line regulation  
Maximum  
Maximum  
%
%
+/- 1  
+/- 1  
Ui nominal  
25% to full load  
Load regulation ****  
+/- 2,5  
+/- 2,5  
Ui nominal  
+ Vout nominal load  
- Vout from 25% to full load  
Cross load output  
regulation  
Maximum  
Typical  
%
%
+/- 0,5  
82  
+/- 0,5  
82  
Ui nominal  
Full load  
Efficiency  
Maximum admissible  
Capacity load  
5V output  
Ui nominal  
Full load  
Per output  
Maximum  
Maximum  
µF  
µF  
470  
100  
470  
100  
12V and 15V output  
Note * : For proper operation the MGDM-10 module requires to install a 22µF chemical or tantalum capacitance accross output terminals.  
Note ** : For 9-36V input range, the current is derated at 80% at 9V and increases linearly to full current at 12V.  
Note*** : The ripple output voltage is the periodic AC component imposed on the output voltage, an aperiodic and random component (noise) has also to be considered.  
This noise can be reduced by adding an external capacitor (typically 10nF/rated voltage depending on isolation requirement) connected between the pin Gin and the  
pin Gout of the converter. This capacitor should be layed-out as close as possible from the converter.  
Note**** : For load regulation characteristics from 0% to full load, please see page 6.  
5
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
3- Electrical Characteristics (continued)  
Figure 1 : Typical efficiency versus load  
at nominal input  
Figure 3 : Typical efficiency versus load  
at nominal input  
Figure 2 : Typical efficiency versus load  
76  
74  
72  
70  
68  
66  
64  
83  
80  
77  
74  
71  
68  
65  
83  
82  
81  
80  
79  
78  
input 5V  
input 5V  
input 5V  
1.65  
Output Power (W)  
3.3  
5
6.6  
2.5  
5
7.5  
10  
2.5  
5
7.5  
10  
(MGDS-10-C-B module)  
Output Power (W)  
(MGDS-10-C-C module)  
Output Power (W)  
(MGDB-10-C-E module)  
Figure 4 : Typical efficiency versus load  
at nominal input  
Figure 5 : Typical efficiency versus load  
at nominal input  
Figure 6 : Typical efficiency versus load  
at nominal input  
83  
81  
79  
77  
75  
73  
71  
86  
84  
82  
80  
78  
76  
74  
85  
83  
81  
79  
77  
75  
73  
input 9V  
input 9V  
input 9V  
input 22,5V  
input 22,5V  
input 36V  
input 22,5V  
input 36V  
input 36V  
2.5  
5
7.5  
10  
2.5  
5
7.5  
10  
2.5  
5
7.5  
10  
4
Output Power (W)  
(MGDS-10-H-C module)  
Output Power (W)  
(MGDS-10-H-E module)  
Output Power (W)  
(MGDS-10-H-F module)  
Figure 7 : Typical efficiency versus load  
at various input  
Figure 8 : Typical efficiency versus load  
at various input  
Figure 9 : Typical efficiency versus load  
at various input  
83  
80  
77  
74  
71  
68  
65  
86  
83  
80  
77  
74  
71  
86  
83  
80  
77  
74  
71  
68  
input 40V  
input 40V  
input 28V  
input 40V  
input 28V  
input 16V  
input 28V  
input 16V  
input 16V  
2.5  
5
7.5  
10  
2.5  
5
7.5  
10  
2.5  
5
7.5  
10  
Output Power (W)  
(MGDS-10-J-C module)  
Output Power (W)  
(MGDS-10-J-E module)  
Output Power (W)  
(MGDS-10-J-F module)  
Figure 10 : Typical load regulation  
characteristics at nominal input  
Figure 11 : Typical load regulation  
characteristics at nominal input  
Figure 12 : Typical load regulation  
characteristics at nominal input  
5,8  
5,7  
5,6  
5,5  
5,4  
5,3  
13,20  
13,00  
12,80  
12,60  
12,40  
12,20  
12,00  
11,80  
16,20  
16,00  
15,80  
15,60  
15,40  
15,20  
15,00  
14,80  
5,2  
5,1  
5
4,9  
,00 ,25 ,50 ,75 1,00 1,25 1,50 1,75 2,00  
0
100 200 300 400 500 600 700 800 900  
0
100  
200  
300  
400  
500  
600  
700  
Output Current (A)  
(MGDS-10-J-C module)  
Output Current (mA)  
(MGDS-10-J-E module)  
Output Current (mA)  
(MGDS-10-J-F module)  
6
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
4- Switching Frequency  
Parameter  
Conditions  
Limit or typical  
Specifications  
Full temperature range  
Ui min. to max.  
Switching frequency  
Nominal, fixed  
480 KHz  
No load to full load  
5- Isolation  
Parameter  
Conditions  
Limit or typical  
Specifications  
Electric strength test voltage  
Input to output  
Minimum  
1.500 VDC / 1 min  
No isolation  
Electric strength test voltage between  
outputs (for dual and triple outputs)  
Output to output  
500 VDC  
Minimum  
Minimum  
Isolation resistance  
100 MOhm  
6- Protection Functions  
Characteristics  
Protection Device  
Recovery  
Limit or typical  
Specifications  
4
Turn-on, turn-off circuit  
with no hysteresis  
Automatic  
recovery  
Input undervoltage lock-out (UVLO)  
Threshold  
Permanent  
See section 3  
Hiccup circuitry with  
auto-recovery  
Automatic  
recovery  
Output short circuit protection (SCP)  
Output overvoltage protection (OVP)  
See section 11  
Maximum  
Maximum  
Maximum  
Maximum  
For 3.3v : 4v  
For 5v : 6v  
For 12v : 14v  
For 15v : 17v  
Zener clamp  
/
7- Reliability Data  
Characteristics  
Conditions  
Temperature  
Specifications  
Case at 40°C  
Case at 85°C  
965.000 Hrs  
385.000 Hrs  
Ground fixed (Gf)  
Mean Time Between Failure (MTBF)  
According to MIL-HDBK-217F  
Airborne, Inhabited,  
Cargo (AIC)  
Case at 40°C  
Case at 85°C  
500.000 Hrs  
180.000 Hrs  
Mean Time Between Failure (MTBF)  
According to IEC-62380-TR  
Avionics Military Cargo  
/
Consult factory  
7
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
8- Electromagnetic Interference  
Electromagnetic Interference requirements according to MIL-STD-461C/D/E standards can be easily achieved as indicated in  
the following section. The following table resumes the different sections covered by these standards.  
MIL-STD-461C  
Standard  
MIL-STD-461D/E  
Standard  
Compliance with GAIA Converter  
Module & common mode capacitance  
Standard Requirements  
Conducted emission (CE) :  
Low frequency  
High frequency  
CE 01  
CE 03  
CE 101  
CE 102  
compliant module stand-alone  
compliant with additionnal filter  
Conducted susceptibility (CS) :  
Low frequency  
High frequency  
CS 01  
CS 02  
CS 101  
CS114  
compliant with additionnal filter  
compliant with additionnal filter  
Radiated emission (RE) :  
Magnetic field  
Electrical field  
RE 01  
RE 02  
RE 101  
RE 102  
compliant module stand-alone  
compliant module stand-alone  
Radiated susceptibility (RS) :  
Magnetic field  
Electrical field  
RS 01  
RS 03  
RS 101  
RS 103  
compliant module stand-alone  
compliant module stand-alone  
Applicability  
H, J input module  
H, J input module  
see EMI datasheet  
8-1 Module Compliance with MIL-STD-461C/D/E Standards  
4
To meet the latest US military standards MIL-STD-461D/E (and also the MIL-STD-461C) requirements and in particular the conducted  
noise emission CE102 (and also CE03) requirements, Gaïa Converter can propose a stand-alone ready-to-use EMI filter module. This  
EMI filter module has to be used together with a common mode noise capacitance Cc (10nF/rated voltage depending on  
isolation requirement) connected between Gin and Gout.  
EMI Filter module reference : FGDM-2A-50V.  
Please consult EMI filter datasheet for further details.  
Vo  
Vo  
VI  
VI  
EMI input Filter  
MGDM-series  
GI  
Go  
GI  
Go  
Cc  
8
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
9- Thermal Characteristics  
Characteristics  
Conditions  
Limit or typical  
Performances  
Operating ambient temperature  
range at full load  
Minimum  
Maximum  
- 40°C  
+ 85°C  
Ambient temperature *  
Case temperature  
Operating case temperature  
range at full load  
Minimum  
Maximum  
- 40°C  
+105°C  
Minimum  
Maximum  
- 55°C  
+ 125°C  
Storage temperature range  
Thermal resistance  
Non functionning  
Rth case to ambient in free air  
natural convection  
Typical  
12°C /W  
Note * : The upper temperature range depends on configuration, the user must assure a max. case temperature of + 105°C.  
The MGDM-10 series operating case temperature must not exceed 105°C. The maximum ambient temperature admissible for  
the DC/DC converter corresponding to the maximum operating case temperature of 105°C depends on the ambient airflow, the  
mounting/orientation, the cooling features and the power dissipated.  
To calculate a maximum admissible ambient temperature the following method can be used. Knowing the maximum case  
temparature Tcase = 105°C of the module, the power used Pout and the efficiency η :  
• determine the power dissipated by the module Pdiss that should be evacuated :  
Pdiss = Pout(1/η - 1)  
• determine the maximum ambient temperature :  
Ta = 105°C - Rth x Pdiss  
where Rth is the thermal resistance from the case to ambient.  
4
The previous thermal calculation shows two areas of operation :  
• a normal operation area in a free natural ambient convection (grey area in this following graph),  
• an area with cooling features (air flow or heatsink) ensuring a maximum case temperature below the maximum  
operating case temperature of 105°C (white area in the following graph).  
Power (W)  
100%  
Additionnal cooling operation area  
75%  
50%  
Natural convection operation area  
25%  
10  
20 30  
40 50 60 70  
80 90 100 110  
Temperature (˚C)  
Full load ambient temperature without derating : 85˚C  
Maximum case temperature : 105˚C  
Maximum storage temperature : 125˚C  
9
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
10- Environmental Qualifications  
The modules have been subjected to the following environmental qualifications.  
Characteristics  
Conditions  
Severity  
Test procedure  
Climatic Qualifications  
Duration  
Temperature / status of unit  
Test D : 1.000 Hrs  
@ 105°C case, unit operating  
@ 125°C ambient, unit not operating  
Life at high  
temperature  
MIL-STD-202G  
Method 108A  
Altitude level C  
Duration  
Climb up  
Stabilization  
Status of unit  
40.000 ft@-55°C  
30 min.  
1.000 ft/min to 70.000 f@-55°C,  
30 min.  
MIL-STD-810E  
Method 500.3  
Altitude  
unit operating  
Number of cycle  
10  
Cycle duration  
Cycle I : 24 Hrs  
60 % to 88 %  
31°C to 41°C  
unit not operating  
MIL-STD-810E  
Method 507.3  
Humidity cyclic  
Relative humidity variation  
Temperature variation  
Status of unit  
Damp heat  
Temperature  
Duration  
93 % relative humidity  
40°C  
56 days  
MIL-STD-202G  
Method 103B  
Humidity steady  
Salt atmosphere  
Status of unit  
unit not operating  
Temperature  
Concentration NaCl  
Duration  
35°C  
5 %  
48 Hrs  
MIL-STD-810E  
Method 509.3  
Status of unit  
unit not operating  
Number of cycles  
Temperature change  
Transfert time  
Steady state time  
Status of unit  
200  
-40°C / +85°C  
40 min.  
20 min.  
unit operating  
Temperature  
cycling  
MIL-STD-202A  
Method 102A  
4
Number of shocks  
Temperature change  
Transfert time  
Steady state time  
Status of unit  
100  
-55°C / +105°C  
10 sec.  
20 min.  
MIL-STD-202G  
Method 107G  
Temperature shock  
unit not operating  
Mechanical Qualifications  
Number of cycles  
10 cycles in each axis  
10 to 60 Hz / 0.7 mm  
60 to 2000 Hz / 10 g  
2h 30 min. per axis  
unit not operating  
Frequency / amplitude  
Frequency / acceleration  
Duration  
Vibration  
(Sinusoidal)  
MIL-STD-810D  
Method 514.3  
Status of unit  
Number of shocks  
Peak acceleration  
Duration  
Shock form  
Status of unit  
3 shocks in each axis  
100 g  
6 ms  
1/2 sinusoidal  
unit not operating  
Shock  
(Half sinus)  
MIL-STD-810D  
Method 516.3  
Number of bumps  
Peak acceleration  
Duration  
2000 bumps in each axis  
40 g  
6 ms  
Bump  
(Half sinus)  
MIL-STD-810D  
Method 516.3  
Status of unit  
unit not operating  
10  
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
11- Description of Protections  
11-1 Input Undervoltage Lock-out (UVLO)  
On  
The input undervoltage lock-out protection device turns-  
on and turns-off the output voltage when the input bus  
voltage reaches the undervoltage lock-out threshold. There  
is no hysteresis cycle at turn-on and turn-off.  
Off  
Vin  
UVLO  
Turn-on/Turn-off  
11-2 Output Short Circuit Protection (SCP)  
Vo (%)  
The short circuit protection device protects the module  
against short circuit of any duration and restores the mo-  
dule to normal operation when the short circuit is removed.  
It operates in «hiccup» mode by testing periodically if an  
overload is applied (typically every 200ms recovery time).  
The overload detection threshold is typically 200% of maxi-  
mum current with a detection time lower than 5ms.  
100  
detection time  
recovery time  
x
time  
recovery time  
11-3 Output Overvoltage Protection (OVP)  
The output overvoltage protection device protects external  
components against high voltage or possible overvoltages  
which can be supplied by the module (i.e in case of internal  
failure). It consists of a zener diode clamping the output  
voltage; under worst case conditions this zener diode will  
short-circuit.  
4
The output voltage protection is not designed to withstand  
externally applied output overvoltages to protect the mo-  
dule itself.  
12- Description of Functions  
12-1 Option (/M) : On/Off Function  
The optionnal control pin A (On/Off) can be used for appli-  
cations requiring On/Off operation. By using an open  
collector command with a transistor Q referenced to the  
common terminal (Gi) :  
On/Off  
• A logic pulled low (<0.2V@1mA, referenced to Gi) on  
pin A disables the converter  
Command  
• No connection or high impedance on pin A enables  
the converter.  
GI  
By releasing the On/Off function, the converter will restart  
within the start-up time specifications given in table page 3.  
For further details please consult ‘’Logic On/Off’’ Applica-  
tion Note.  
11  
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
13- Application Notes  
13-1 Connection of Outputs in Series  
Any of the bi output converters can be configured to produce  
an output of 10V (+/-5 output models), 24V (+/-12V out-  
put models), or 30V (+/-15V output models) by connecting  
the load across the output (+) and the output (-) with  
either output grounded, and leaving the common pin  
floating.  
VI  
GI  
+Vo  
Go  
2 x Vo  
-Vo  
13-2 Connection of Modules in Series  
The output of single output units can be connected in series  
without any precautions to provide higher output voltage  
level.  
VI  
Vo  
Nevertheless, GAIA Converter recommends to protect each  
individual output by a low power shottky diode rated with  
the maximum current of the converter to avoid reverse  
polarity at any output.  
Reverse polarity may occur at start up if the output volta-  
ges do not rise at the same time.  
Gate  
GI  
Go  
Vo  
2 x Vo  
VI  
4
Gate  
GI  
Go  
13-3 Connection of Modules in Parallel  
The MGDM-10 series feature a current share function. Several  
converters with equal output voltage can be connected in  
parallel to increase power.  
A «master» module will synchronize a «slave» module to  
the same clock allowing a current share in between modu-  
les through the «gate» pin.  
VI  
Vo  
Master  
Gate  
Vo  
GI  
VI  
Go  
Vo  
A master module MGDS-10 can drive up to 2 slave modules  
MGDE-10 .  
Slave  
Gate  
GI  
Go  
12  
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
Hi-Rel  
Grade  
MGDM-10 Series  
14- Dimensions  
Dimension are given in mm (inches). Tolerance : +/- 0,2 mm (+/- 0.01 “) unless otherwise indicated.  
Weight : 20 grams (0.7 Ozs) max.  
40  
26  
26  
(1.58")  
(1.03")  
(1.03")  
7,60  
Single & Bi & Tri output models  
Single & Bi output models  
Tri output model  
8
(0.30")  
(0.32")  
5 min  
10,16  
7,62  
(0.3")  
10,16  
(0.40")  
7,62  
26,20  
(0.20")  
(0.40")  
(0.3")  
(1.03")  
2 (0.078")  
35,56  
20,32  
10,16  
(0.40")  
(1.40")  
(0.80")  
Pin dimensions : O 0,73 mm (0.03 ”)  
Metallic case black anodized coating solder plated pin  
15- Product Marking  
Upper face : Company logo, location of manufacturing.  
Side face : Module reference, option, date code : year and week of manufacturing.  
4
16- Connections  
Pin  
1
Single  
Bi  
Triple  
+ Input (Vi)  
No pin  
4
5
6
4
7
8
6
+ Input (Vi) + Input (Vi)  
2
Gate  
No pin  
3
- Input (Gi) - Input (Gi)  
- Input (Gi)  
4
Output (Vo) Output + (+Vo) Output 1 (V1)  
No pin Common (Go)  
5
/
6 Common (Go) Output - (-Vo) Common (Go)  
7
8
A
/
/
/
/
Output 2+ (+V2)  
Output 2- (-V2)  
No pin *  
A
2
A
2
No pin *  
No pin *  
1
3
1
3
* Option /M : Pin A existing for On/Off function.  
Please add /M to module reference.  
Single & Bi output models  
Bottom view  
Tri output models  
13  
Gaia Converter FC97-010.08/08 Revision P  
©
For locations, phone, fax, E-Mail see back cover  
For more detailed specifications and applications information, contact :  
International Headquarters North American Headquarters  
Marketing and Sales department GAÏA Converter Canada, Inc  
GAÏA Converter - France Address : 6611 Thimens  
Address : B.P. 26 - 33186 LE HAILLAN - FRANCE ST-LAURENT, QUEBEC - CANADA H4S 1W2  
Tel. : + (33)-5-57-92-12-80 Tel. : (514)-333-3169  
Fax : + (33)-5-57-92-12-89 Fax : (514)-333-4519  
Represented by :  
Information given in this datasheet is believed to be accurate and reliable. However, no responsibility is assumed for the consequence of its use nor for any infringement of patents or other rights of third parties which may result from its use.  
These products are sold only according to GAIA Converter general conditions of sale, unless otherwise confirmed by writing. Specifications subject to change without notice.  

相关型号:

MGDS-10-J-C/T

Hi-Rel DC/DC CONVERTER 10W POWER
ETC

MGDS-10-J-E

Hi-Rel DC/DC CONVERTER 10W POWER
ETC

MGDS-10-J-F

Hi-Rel DC/DC CONVERTER 10W POWER
ETC

MGDS-150-H-B

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-B-S

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-B-T

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-B/S

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-B/T

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-C

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-C-S

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-C-T

Hi-Rel DC/DC CONVERTER
ETC

MGDS-150-H-C/S

Hi-Rel DC/DC CONVERTER
ETC