MLX90242  
Linear Hall Effect Sensor  
Features and Benefits  
· Small Plastic Package (SOT-23, 4-SIP-VA, TO-92)  
· Quad Switched Hall Plate / Chopper Stabilized Amplifier  
· Ratiometric Output for A/D Interface  
· Low Quiescent Voltage Thermal Drift  
Applications  
· Linear Position Sensing  
· Rotary Position Sensing  
· Current Sensing  
Ordering Information  
Part No.  
Sensitivity  
Voq  
TC  
Temp. Range  
Package Nb pins  
MLX90242LUA-CC03  
MLX90242LVA-CC03  
MLX90242ESO-BC03 15 mV/mT (± 1300G) 2.50 V  
40 mV/mT (± 500G) 2.50 V  
40 mV/mT (± 500G) 2.50 V  
700 ppm/°C -40C to 150C  
700 ppm/°C -40C to 150C  
UA  
VA  
SO  
SO  
3
4
3
3
-
-40C to 85C  
MLX90242ESO-CC03 40 mV/mT (± 500G) 2.50 V  
-
-40C to 85C  
1. Functional Diagram  
2. Description  
The MLX90242 is a CMOS Linear Hall Effect  
sensor IC. It possesses active error correction  
circuitry which virtually eliminates the offset  
errors normally associated with analog Hall  
Effect devices.  
VDD  
Output  
Chopper  
The ratiometric output voltage is proportional to  
the supply voltage. When using the supply  
voltage as a reference for an A/D converter,  
fluctuations of +10% in supply voltage will not  
affect accuracy. For a positive slope, the voltage  
at the output will increase as a South magnetic  
field is applied to the branded face of the  
MLX90242. Conversely, the voltage output will  
decrease in the presence of a North magnetic  
field. For a negative slope, the voltage at the  
output will increase as a North magnetic field is  
applied to the branded face of the MLX90242.  
Conversely, the voltage output will decrease in  
the presence of a South magnetic field.  
Package Pin1 Pin2 Pin 3 Pin4  
Slope  
SOT23  
VDD Out VSS  
Positive  
UA  
VA  
VDD VSS Out  
VDD n/c VSS  
Negative  
Positive  
Out  
3901090242  
Rev. 024  
Page 1 of 7  
Data Sheet  
Mar/04  
MLX90242  
Linear Hall Effect Sensor  
TABLE OF CONTENTS  
FEATURES AND BENEFITS .............................................................................................................. 1  
APPLICATIONS ................................................................................................................................. 1  
ORDERING INFORMATION ............................................................................................................... 1  
1. FUNCTIONAL DIAGRAM ......................................................................................................... 1-1  
2. DESCRIPTION ......................................................................................................................... 2-1  
3. GLOSSARY OF TERMS.............................................................................................................. 3  
4. ABSOLUTE MAXIMUM RATINGS ............................................................................................... 3  
5. MLX90242 ELECTRICAL SPECIFICATIONS................................................................................ 4  
6. MLX90242 MAGNETIC SPECIFICATIONS ................................................................................... 4  
7. APPLICATIONS INFORMATION.................................................................................................. 5  
8. INSTALLATION COMMENTS ...................................................................................................... 5  
9. RELIABILITY INFORMATION...................................................................................................... 5  
10. ESD PRECAUTIONS ................................................................................................................... 6  
11. PACKAGE INFORMATION.......................................................................................................... 6  
3901090242  
Rev. 024  
Page 2 of 7  
Data Sheet  
Mar/04  
MLX90242  
Linear Hall Effect Sensor  
3. Glossary of Terms  
- Gauss, Tesla: Two units to quantify a magnetic flux density. Conversion: 1 mT = 10 Gauss  
- Voq: Quiescent output voltage. Output voltage for B = 0.  
4. Absolute Maximum Ratings  
Supply Voltage (Over Voltage), VDD  
Output Current Short to Vdd  
Output Current Short to Vss  
Output Pin Short to Vss Pin  
Output Over Voltage  
7.0 V  
5 mA  
0.5 mA  
Infinite  
8 V  
Operating Temperature Range, TA  
Storage Temperature Range, TS  
Maximun Junction Temp, TJ  
Magnetic Flux Density  
-40°C to 150°C  
-55°C to 150°C  
170°C  
Infinite  
Exceeding the absolute maximum ratings may cause permanent damage. Exposure to absolute-  
maximum-rated conditions for extended periods may affect device reliability.  
3901090242  
Rev. 024  
Page 3 of 7  
Data Sheet  
Mar/04  
MLX90242  
Linear Hall Effect Sensor  
5. MLX90242 Electrical Specifications  
DC Operating Parameters. L: TA = -40 to 150°C, E: TA = -40 to 85°C  
VDD = 5.0V (Unless otherwise specified)  
Parameter  
Symbol Test Conditions  
Min  
Typ Max  
Units  
Supply Voltage  
Supply Current  
Output Current  
VDD  
IDD  
Operating  
4.5  
1.8  
5.0  
2.5  
-
5.5  
4.5  
0.1  
V
B = 0, VDD = 5V, IOUT = 0  
mA  
mA  
IOUT  
VDD = 5V  
-1.0  
Pull-up = 5 kO, Pull-down = 50 kO  
B = 0, TA = 25°C  
Quiescent Output Voltage  
Output Voltage  
VOQ  
VOH  
VOL  
tr  
2.4  
2.5  
2.6  
V
V
VDD = 5V, IOUT = -1.0 mA  
VDD = 5V, IOUT = 0.1 mA  
4.75  
Output Voltage  
0.25  
800  
V
Response Time  
Vdd=5V,Vout from Voq to VOH/VOL  
without load  
400  
µS  
Noise (RMS)  
5
10  
mV  
W
Output Resistance  
Linearity Error  
ROUT  
Le  
20  
0.5  
%Vdd  
6. MLX90242 Magnetic Specifications  
L: TA = -40 to 150°C, E: TA = -40 to 85°C  
VDD = 5.0V (Unless otherwise specified)  
MLX90242LUA-CC03 MLX90242LVA-CC03  
MLX90242ESO-BC03 MLX90242ESO-CC03  
Parameter  
Symbol  
Min  
-25  
Typ Max Min  
25 -25  
Typ Max Min  
Typ Max Min  
Typ Max  
DTVOQ  
S
Thermal Voq Drift (1)  
(mV)  
Sensitivity, TA = 25° C  
(mV/mT)  
25  
+/- 25 (2)  
+/- 25 (2)  
33.2 39.0 44.9 35.3 41.5 47.7 11.5  
430 680 930 430 680 930  
15  
17.3 33.2 39.0 44.9  
680 (2)  
TC of Sensitivity  
(ppm/°C)  
TCS  
680 (2)  
(1) B = 0, TA = -40 to 150°C  
(2) For ESO package, TC of Sensitivity and Thermal Voq Drift are not fully tested and therefore cannot be specified.  
Characterization and statistic data can be provided by Melexis upon request.  
3901090242  
Rev. 024  
Page 4 of 7  
Data Sheet  
Mar/04  
MLX90242  
Linear Hall Effect Sensor  
7. Applications Information  
C1 and C2 values can be trimmed to satisfied  
EMC requirements according to the environment  
(PCB, connectors,...).  
Recommended Wiring  
The output rise time is affected for large  
capacitor C2, depending of the couple R1;C2.  
VDD  
8. Installation Comments  
3
MLX  
90242  
1.) Avoid mechanical stress on leads or  
package.  
C1 = 10nF  
R1 = 10 k  
1
2
Stress may cause VOQ shift.  
VOUT  
A.) Avoid bending leads at the package interface.  
B.) Support the leads by clamping, when bending.  
C.) Avoid gluing device to another material.  
C2 = 2.5nF  
This may cause temperature-related stress.  
2.) CMOS products are static sensitive devices,  
please observe ESD precautions.  
3.) Observe temperature limits during soldering  
9. Reliability Information  
Melexis devices are classified and qualified regarding suitability for infrared, vapor phase and wave  
soldering with usual (63/37 SnPb-) solder (melting point at 183degC).  
The following test methods are applied:  
IPC/JEDEC J-STD-020A (issue April 1999)  
Moisture/Reflow Sensitivity Classification For Nonhermetic Solid State Surface Mount Devices  
CECC00802 (issue 1994)  
Standard Method For The Specification of Surface Mounting Components (SMDs) of Assessed Quality  
MIL 883 Method 2003 / JEDEC-STD-22 Test Method B102  
Solderability  
For all soldering technologies deviating from above mentioned standard conditions (regarding peak  
temperature, temperature gradient, temperature profile etc) additional classification and qualification tests  
have to be agreed upon with Melexis. For process using through hole components, a temperature profile  
of 235 Deg.C during 30 seconds maximum is tolerated.  
The application of Wave Soldering for SMD’s is allowed only after consulting Melexis regarding assurance  
of adhesive strength between device and board. Please contact MLX for Ua part used as SMD device.  
For more information on manufacturability/solderability see quality page at our website:  
http://www.melexis.com/  
3901090242  
Rev. 024  
Page 5 of 7  
Data Sheet  
Mar/04  
MLX90242  
Linear Hall Effect Sensor  
10. ESD Precautions  
Electronic semiconductor products are sensitive to Electro Static Discharge (ESD).  
Always observe Electro Static Discharge control procedures whenever handling semiconductor products.  
11. Package Information  
UA Package Dimensions  
45o  
Typical  
UA Hall Plate / Chip Location  
1.60  
1.40  
1.95 +/- 0.15  
0.45  
0.41  
4.30  
3.90  
0.84  
0.63  
Hall Plate dimension:  
0.150x0.150  
o
o
Max 5  
Typ 5  
2.64  
2.34  
*
42GA  
2053  
3.20  
2.80  
Max 5 o  
Marked  
Surface  
0.48  
0.43  
1.75  
1.55  
0.7 Max  
All Dimensions in millimeters  
0.38  
Typical  
(see note 3)  
0.20  
0.00  
* MARKING:  
Line 1:  
0.41  
0.35  
1st and 2nd digits (42) = Part Number MLX90242  
NOTES:  
1.) Controlling dimension: mm  
2.) Leads must be free of flash and  
plating voids  
3.) Leads must not arc toward  
the rear of package  
3rd and 4th digits (GA)  
=
Version number  
15.0  
14.0  
1
2
3
Line 2:  
1st digit (2)  
= Year (2002)  
2nd and 3rd digits(05)  
= Week of Year  
4.) Package dimensions exclude  
molding flash  
4th digit (3)  
= Last Lotnumber Digit  
5.) Tolerance is 0.254mm unless  
otherwise specified  
PINOUT:  
Pin 1  
Pin 2  
Pin 3  
VDD  
GND (Vss)  
Output  
1.30  
1.24  
0.41  
0.35  
2.57  
2.51  
SOT-23 Package Dimensions  
SOT-23 Hall Plate / Chip Location  
* MARKING:  
1&2 Digits (42) = Part Number (90242)  
Bottom View of Package  
0.50  
0.35  
0.20  
MIN  
3,4&5 Dgits(951) =Last Lotnumber Digits  
3
PINOUT:  
Pin 1  
0 +/- 0.15  
3.00  
2.60  
VDD  
*
NOTES:  
1.) Controlling dimension: mm  
1.80  
Pin 2  
Outpout  
42951 1.50  
chip  
0.66  
0.56  
Pin 3  
GND  
2.) Lead thickness after solder plating will  
be 0.254 mm maximum  
3.) Package dimensions exclude molding  
flash  
1
2
0.25  
0.10  
3
2.10  
1.70  
4.) The end flash shall not exceed 0.127 mm  
on each side of package  
5.) Tolerance is 0.254mm unless otherwise  
specified  
3.10  
2.70  
0.10  
0.00  
0.90  
0.70  
1.30  
1.00  
MLX90242  
2
1
3901090242  
Rev. 024  
Page 6 of 7  
Data Sheet  
Mar/04  
MLX90242  
Linear Hall Effect Sensor  
5.33  
5.43  
VA Package Dimensions  
5.08  
5.24  
VA Hall Plate / Chip Location  
1.88 +/- 0.15  
J
Hall Plate  
0.15 x 0.15  
1.22  
1.32  
3.76  
3.86  
0.387  
0.289  
4.50  
4.10  
A
B
C
MLX 90242  
45o X 1mm  
5o  
5o  
(2x)  
(2x)  
*
242GA  
XXXXXXX  
Marked  
Surface  
3.46 3.79  
3.30 3.63  
0.387  
0.289  
D
Reference (0,0)  
VA  
F
All Dimensions in millimeters  
1.20  
1.10  
E
G
H
A
B
C
D
E
F
0.22  
REF  
1.0  
MAX  
0.66  
0.61  
1
2
3
Notes:  
1. Pinout: Pin 1  
Pin 2  
4
0.29  
0.24  
VDD  
n/c  
GND  
Output  
15.50  
14.50  
45 o  
Pin 3  
Pin 4  
0.31  
0.18  
0.60  
0.40  
2. Controlling dimension: mm .  
0.45  
0.35  
3. Leads must be free of flash and plating voids.  
4. Leads must not arc toward the rear of package.  
5. Package dimensions exclude molding flash.  
6. Tolerance: +/- 0.254 mm unless otherwise specified.  
9. *Marking:  
0.35  
0.25  
G
H
J
0.15  
0.0  
45 o  
Line 1:  
1st three digits (242)  
4th and 5th digits (GA)  
= Part Number  
= Revision Number  
Line 2:  
7 Digits  
=Lot Number  
Back Side Marking  
YYWW  
=Lot Number  
=DateCode  
Go to our website at  
www.melexis.com  
Or for additional information contact Melexis Direct:  
Europe and Japan:  
All other locations:  
Phone: +1 603 223 2362  
E-mail: sales_usa@melexis.com  
Phone: +32 13 67 0495  
E-mail: sales_europe@melexis.com  
QS9000, VDA6.1 and ISO14001 Certified  
3901090242  
Rev. 024  
Page 7 of 7  
Data Sheet  
Mar/04  

相关型号:

MLX90242_04

Linear Hall Effect Sensor
ETC

MLX90242_12

Linear Hall Effect Sensor
MELEXIS

MLX90247

Discrete Infrared Thermopile Detectors
MELEXIS

MLX90247B

Thermopile w/On-Chip Thermistor
ETC

MLX90247C

Thermopile w/NTC Thermistor
ETC

MLX90247DSA

Discrete Infrared Thermopile Detectors
ETC

MLX90247DSE

Discrete Infrared Thermopile Detectors
ETC

MLX90247DSG

Discrete Infrared Thermopile Detectors
ETC

MLX90247_04

Discrete Infrared Thermopile Detectors
ETC

MLX90247_07

Discrete Infrared Thermopile Detectors
ETC

MLX90248

Micropower & Omnipolar Hall Switch
MELEXIS

MLX90248ELDEBA-000RE

Micropower & Omnipolar Hall Switch
MELEXIS