MU25ASR230

更新时间:2024-09-18 12:50:02
品牌:ETC
描述:Manual Motor Starter MU

MU25ASR230 概述

Manual Motor Starter MU 手动电动机起动器MU

MU25ASR230 数据手册

通过下载MU25ASR230数据手册来全面了解它。这个PDF文档包含了所有必要的细节,如产品概述、功能特性、引脚定义、引脚排列图等信息。

PDF下载
Manual Motor Starter MU  
Overload protection  
Short circuit protection  
Phase differential detection  
DIN rail mounting  
Test facility  
Ambient temperature compensation  
Fingertouch protection  
Lockable off position  
Designed to EN60947-4-1 and EN60947-2  
Bus-bar system  
Enclosures  
Options and ordering codes  
Specification  
Current Range  
Amps  
Magnetic Short  
Product  
Rated insulation voltage UI  
Rated current Ith open, at 50˚C  
Mechanical life  
690V AC  
Circuit Trip-Amps  
25 amps  
0.10 - 0.16  
0.16 - 0.25  
0.25 - 0.40  
0.40 - 0.63  
0.63 - 1.00  
1.00 - 1.60  
1.60 - 2.50  
2.50 - 4.00  
4.00 - 6.30  
6.30 - 10  
10 - 16  
1.92  
3.0  
MU25A 0.16  
MU25A 0.25  
MU25A 0.40  
MU25A 0.63  
MU25A 1.00  
MU25A 1.60  
MU25A 2.50  
MU25A 4.00  
MU25A 6.30  
MU25A 10  
100,000 ops  
100,000 ops  
30 ops per hour  
7 mS  
Electrical life – AC3 duty  
Switching frequency  
4.8  
7.6  
Operate time – approximately  
Total power loss (warm condition)  
Temperature compensation open  
Rating auxiliary switch – AC15  
Mounting position  
12.0  
19.2  
30  
6-8 W  
–20 to +55˚C  
400V 2A  
48  
Any  
75.6  
120  
192  
240  
300  
Power consumption – undervoltage trip  
– shunt trip  
2.7VA 1.8W  
2.7VA 1.8W  
0.75 – 4mm2  
0.75 – 2.5mm2  
0.25 Kg  
MU25A 16  
Terminal wiring cross section 1 or 2 wires main  
aux  
16 - 20  
MU25A 20  
20 - 25  
MU25A 25  
Weight  
Accessories  
Auxiliary Contacts  
Shunt Trip  
For fitting to the side of the unit  
max 1 block each side.  
Trips out the unit as voltage is applied.  
Mounting inside the unit.  
Contacts  
Product  
Voltage  
Product  
1 Make + 1 Break  
(internal mount)  
MU25A PE11  
24 AC  
MU25A A24  
MU25A A110  
MU25A A240  
MU25A A400  
110 AC  
1 Break  
MU25A PS01  
MU25A PS11  
MU25A PS20  
MU25A PV20  
220-240 AC  
380-415 AC  
1 Make + 1 Break  
2 Makes  
2 Early Makes  
MU/03/03  
www.imopc.com  
Manual Motor Starter MU continued  
Accessories continued  
Undervoltage Trip  
Current Limiter  
Trips out the unit should the voltage fall  
below 70% of the rated voltage, prevents  
automatic restart when voltage returns.  
For mounting inside the unit.  
For increasing the fault breaking capacity of  
single unit or group back-up to 50kA.  
UI = 690V  
IU = 32A  
Product  
Voltage  
Product  
MBS25 ID50  
220-240 AC  
380-415 AC  
24 AC  
MU25A U230  
MU25A U400  
MU25A U24  
MU25A U110  
110 AC  
Starter Carrier  
Accepts contactor and manual motor starter  
to mount onto one DIN rail.  
Bus-Bar System  
Product  
System for connecting units together and  
incoming supply.  
MBS25 PL54  
Fully isolated UI = 690V IU = 63 amps  
Description  
Product  
For 2 units - 99mm  
For 3 units - 154mm  
For 4 units - 208mm  
For 5 units - 262mm  
MBS25 D99  
MBS25 D154  
MBS25 D208  
MBS25 D262  
Enclosures  
Description  
Product  
Protection for unused terminals MBS25 BS  
Moulded enclosure - IP55 MU25A O55  
Moulded front plate - IP55 MU25A C55  
Locking Bracket - 3 position MU25A Z  
Supply Block  
MBS25 DB  
P730  
Spacing Piece 1/2 TE  
Mushroom stop button  
Green Indicator 240V  
Red Indicator 240V  
MU25A NAT  
MU25A SG230  
MU25A SR230  
Earth or neutral conductor MU25A NL  
Moulded enclosure CEE Socket MU25A GC1  
Electrical Characteristics  
Trip curve  
Current Range Rated Short Circuit Capacity kA  
Back-up Fuse (gI)  
Trip curve  
220-240 380-415  
500  
100  
100  
100  
100  
100  
100  
3
660-690 220-240 380-415  
500  
25  
35  
50  
50  
63  
63  
63  
660-690  
1. Three phase trip curve  
0.10 - 0.16 100  
100  
100  
100  
100  
100  
100  
100  
100  
100  
6/50*  
100  
100  
100  
100  
100  
100  
2.5  
2.5  
2.5  
2.5  
2
80  
80  
80  
80  
80  
80  
80  
25  
25  
35  
35  
35  
50  
50  
0.16 - 0.25 100  
0.25 - 0.40 100  
0.40 - 0.63 100  
0.63 - 1.00 100  
1.00 - 1.60 100  
1.60 - 2.50 100  
2.50 - 4.00 100  
4.00 - 6.30 100  
Average value of typical  
tolerance curves from  
cold condition  
3
3
6.30 - 10  
10 -16  
100  
3
10/100* 4/50*  
10/100* 4/50*  
10/100* 4/50*  
2.5  
2.5  
2.5  
16 - 20  
20 - 25  
2
2
*KA with current limiter MBS25-ID50 up to 415V AC  
Fuse not required  
x setting current  
MU/03/03  
www.imopc.com  
Manual Motor Starter MU continued  
Dimensions (mm)  
Manual Motor Starter  
Moulded Enclosure  
80  
97.5  
MU25A  
MU25A-O55  
55  
20  
38  
4 x PG16  
Rail according to  
DIN EN 50 022  
76  
43  
23  
ø4.5  
45  
9
M4  
30  
72  
82  
Aux. contact  
Moulded Front Plate  
Moulded Enclosure for 5-pole CEE-plug  
MU25A-C55  
MU25A-GC1  
85  
max. 6  
M4  
6 8  
80  
14  
42.5  
85  
ø21  
103  
130  
70-72  
R4-6  
70-72  
M4  
45  
33-34  
Mounting  
with clamps  
64  
with screws  
MU/03/03  
www.imopc.com  

MU25ASR230 相关器件

型号 制造商 描述 价格 文档
MU25AU110 ETC Manual Motor Starter MU 获取价格
MU25AU230 ETC Manual Motor Starter MU 获取价格
MU25AU24 ETC Manual Motor Starter MU 获取价格
MU25AU400 ETC Manual Motor Starter MU 获取价格
MU25AZ ETC Manual Motor Starter MU 获取价格
MU26 MOSPEC POWER RECTIFIERS(2.0A,50-400V) 获取价格
MU2646 CENTRAL MU4893 获取价格
MU2646M CENTRAL MU4893 获取价格
MU27 MOSPEC POWER RECTIFIERS(2.0A,500-1000V) 获取价格
MU28 MOSPEC POWER RECTIFIERS(2.0A,500-1000V) 获取价格

MU25ASR230 相关文章

  • Bourns 密封通孔金属陶瓷微调电位计产品选型手册(英文版)
    2024-09-20
    5
  • Bourns 精密环境传感器产品选型手册(英文版)
    2024-09-20
    8
  • Bourns POWrTher 负温度系数(NTC)热敏电阻手册 (英文版)
    2024-09-20
    8
  • Bourns GMOV 混合过压保护组件产品选型手册(英文版)
    2024-09-20
    6