NT2S-CN121 [ETC]
CABLE HMI ; CABLE HMI\n型号: | NT2S-CN121 |
厂家: | ETC |
描述: | CABLE HMI
|
文件: | 总4页 (文件大小:72K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Operator Interface
NT2S
Powerful and Compact Alphanumeric
Operator Interface
■ High visibility LED backlit LCD display
shows 2 lines of 16 characters
■ Choose programmable or message
display models
■ Compact, fits 1/8 DIN panel cutout
■ Six programmable function keys
■ Two programmable LED indicators
■ Powered by peripheral port or 24 VDC
power supply
■ Password protect any function key
■ Bar graph display
■ cCSAus and CE approvals
■ IP65 protection rating
■ Programming software included
at no cost
Ordering Information
Item
Part number
2 x 16 character LCD text, 6 function key, RTC, 24 VDC
2 x 16 character LCD text, 6 function key, 5 VDC
2 x 16 character LCD text message display, 6 function key, 5 VDC
9-pin to peripheral port cable, 2 m for SF121 model
9-pin to peripheral port cable, 5 m for SF121 model
9-pin to peripheral port cable, 2 m for SF122 and SF123 models
9-pin to peripheral port cable, 5 m for SF122 and SF123 models
NT2S-SF121B-E
NT2S-SF122B-E
NT2S-SF123B-E
NT2S-CN212
NT2S-CN215
NT2S-CN222
NT2S-CN225
NT2S
NT2S
Specifications
■ FEATURES
Features
Description
Windows Software Package - NT2ST
NT2S-SF121B-E
Yes
NT2S-SF122B-E
NT2S-SF123B-E
Programming package
Yes
No
Not programmable
Yes
ASCII controlled messages ASCII in PLC registers is displayed on the NT2S No
screen. Pointer in PLC memory tells NT2S which
register to display. Pointers placed in that PLC
register point to data value to be displayed.
Multi-vendor support
Omron, Allen-Bradley Micrologix and SLC 5/0x, Yes
GE Micro, Modicon, Keyence KV Series,
Toshiba T Series, Koyo 305, 405, and DL205
Series
No
No
Memory
Type EEPROM
8 K
8 K
8 K
Power
24 VDC terminals or PLC peripheral port 5 VDC 24 VDC
5 VDC
Yes
Yes
Yes
Yes
Yes
Yes
5 VDC
Yes
Yes
Yes
Yes
Yes
Yes
Enclosure ratings
Standards
IP65
Yes
Yes
Yes
Yes
Yes
Yes
CE, cCSAus
0 to 50°C
-20°C to 60°C
Ambient operating rating
Storage temperature
Ambient operating humidity 35% to 85% with no condensation
Ambient operating
environment
No corrosive gases
Weight
400 g
Yes
Yes
Yes
Yes
Yes
Yes
Panel fitting
2 clamps
Face dimensions
mm (inch)
Dimensions of NT2S front bezel
109W x 60H
(4.29 x 2.36)
109W x 60H
(4.29 x 2.36)
109W x 60H
(4.29 x 2.36)
Rear unit dimensions
mm (inch)
Dimensions of portion of NT2S that enters panel 91W x 44H x 44D 91W x 44H x 44D 91W x 44H x 28D
(3.58 x 1.73 x 1.73) (3.58 x 1.73 x 1.73) (3.58 x 1.73 x 1.10)
Panel cutout
mm (inch)
Recommended panel cutout
dimensions: 1/8 DIN
92W x 45H
(3.62 x 1.77)
92W x 45H
(3.62 x 1.77)
92W x 45H
(3.62 x 1.77)
■ DISPLAY
Features
Description
NT2S-SF121B-E
2 * 16
NT2S-SF122B-E
2 * 16
NT2S-SF123B-E
2 * 16
Display
Lines * characters
mm (inch)
Character height
Backlit
4.35 (0.17)
Yes
4.35 (0.17)
Yes
4.35 (0.17)
Yes
LED backlight
mm (inch)
Effective display area
60 x 13
60 x 13
60 x 13
(2.36 x 0.51)
(2.36 x 0.51)
(2.36 x 0.51)
Indicators
Red and green LED indicators
Yes
250
Yes
250
Yes
NA
Number of screens
Max. number of screens if only text messages
are used. Adding function keys, scrolling
messages, etc. decreases the maximum
number of screens.
Data format
HEX, BCD, OCT, BIN, signed, unsigned
Yes
Yes
Controlled by PLC
2
NT2S
NT2S
■ FUNCTION KEYS
Features
Description
NT2S-SF121B-E
NT2S-SF122B-E NT2S-SF123B-E
Available function keys
Number of user programmable function keys
6
6
6 fixed function
Global function key program Function key can be programmed for global
functions. Key program is effective throughout
the NT2S program.
Yes
Yes
NA
Local function key program
Function key can be programmed uniquely
for each screen.
Yes
Yes
Yes
NA
Function key binary action
Momentary, toggle on, toggle off, set on, set off
Yes
Yes
NA
NA
Function key numeric action Set constant value, increment, or decrement by Yes
a constant value to PLC register.
Numeric entry
Special screen uses arrow, clear, and enter keys Yes
to input numeric values to PLC register.
Yes
Yes
Yes
NA
Function key screen
Global function key actions can be linked to
a function key screen that displays upon
activation of that function key. This can be used
to confirm function key.
Yes
Password protect any key
Password can be activated for any function key. Yes
Yes
NA
■ COMMUNICATIONS
Features
Description
NT2S-SF121B-E
NT2S-SF122B-E NT2S-SF123B-E
COM port 1
Programming & Printing port
Host PLC communications
DB9 connector
RS-232 Port
DB9 connector
RS-232 Port
NA
COM port 2
DB9 connector
CMOS/
DB9 connector
CMOS port
DB9 connector
CMOS port
RS-232 port
■ SPECIAL FUNCTIONS
Features
Description
2-digit year, month, date, hour, minute, second
NT2S-SF121B-E
Yes
NT2S-SF122B-E NT2S-SF123B-E
Real time clock
NA
NA
Yes
NA
NA
NA
NA
2 user definable LEDs
Scrolling messages
Flashing display
Minimum display time
Screen chaining
Red and green LED can be controlled from PLC Yes
Yes
Yes
Yes
Yes
Yes
Scroll messages up to 256 characters
Specify for backlight to flash
Yes
Yes
Yes
Yes
Define minimum display time for a screen
Chained screens will display in sequential
fashion, each displaying for the set minimum
display time.
Link screen
Create a list of screens that can be navigated
using the NEXT (F1) and PREVIOUS (F2) keys.
Yes
Yes
Yes
Yes
NA
Bar graph display
Display numeric values as a bar graph
Yes
■ PRINT FUNCTIONS
Features
Description
NT2S-SF121B-E
Yes
NT2S-SF122B-E NT2S-SF123B-E
Yes No
Print screen
Configure serial communications port to
communicate with a printer. Print screen text
and displayed PLC data values can be printed.
3
NT2S
NT2S
Operations
■ NT2S-SF121B-E
■ NT2S-SF123B-E
Key Features
Key Features
• Unit programmed with Windows -based software included
with each unit at no charge
This is not a typical message display. The NT2S-SF123B-E is a
message display with function keys that provide data entry and
screen changing capability. The unit displays ASCII characters
that are stored in PLC registers. The displayed data register is
controlled by a command register which specifies the register
number to be viewed. PLC registers can be programmed to
display text or numeric values from other PLC memory
locations using pointers. Numeric values displayed on screen
can be modified by entering the DATA mode and using the up
and down arrow function keys.
• 24 VDC from external power supply
• Real time clock — year, month, date, hour, minute and
second sent to specified PLC registers
• Supports Omron PLCs
• Supported multi-vendor PLCs
- Omron Host Link
- Allen-Bradley Micrologix and SLC 5/0X (DF1)
- GE Micro
- Modicon (Modbus Master)
- Keyence KV Series
• 5 VDC power supplied by PLC peripheral port
• Supports all Omron PLCs
• Preset function keys allow navigation through PLC registers,
selection of data for modifications and entry of new values
- Toshiba T Series
- Koyo 305, 405 and DL205 Series
■ NT2S-SF122B-E
Key Features
• Unit programmed with Windows -based software included
with each unit at no charge
• 5 VDC power supplied by PLC peripheral port
• For use with Omron PLCs
Dimensions
Unit: mm (inch)
■ OPERATOR INTERFACES
NT2S-SF121B-E
NT2S-SF122B-E
44 (1.73)
91 (3.58)
60
(2.36)
Panel cutout 1/8 DIN
92 (3.62)
109 (4.29)
44 (1.73)
45 (1.77)
44 (1.73)
NT2S-SF123B-E
91 (3.58)
60
(2.36)
109 (4.29)
28 (1.10)
OMRON ELECTRONICS, INC.
One East Commerce Drive
Schaumburg, IL 60173
OMRON CANADA, INC.
885 Milner Avenue
Scarborough, Ontario M1B 5V8
1-800-55-OMRON
416-286-6465
Cat. No. P09FAD1
11/99
Specifications subject to change without notice.
Printed in the U.S.A.