OA5669.16 [ETC]
Safety relay; 安全继电器型号: | OA5669.16 |
厂家: | ETC |
描述: | Safety relay |
文件: | 总4页 (文件大小:120K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Safety relay
OA / OW 5669
• according to EN 50 205, IEC/EN 60 255,
IEC 60 664-1
• with positively driven contacts
• wash proof model as option
• double and reinforced insultaion between
contact sets according to EN 50 178
• low rated power consumption
• high mechanical service life
• compact size, small height
• Approvals: UL, CSA,
TÜV approval: R 9012316
Applications:
ZH1/457 press controls
Switchgear for safety technology
OA / OW 5669
Technical data
Relay type
OA 5669
1. 0 Relay coil
1. 1 Nominal voltage
1. 2 Nominal consumption
DC V
W
5, 6, 12, 20, 24, 48, 60, 110
0,7
2. 0 Contacts
2. 1 Contact arrangement
1 NC / 1NO
2 changeover contacts, 1 No and 1 changeover contact
AgCdO + 0,2 µm Au; AgNi 10 + 0,2 µm Au optionally + 5 µm Au
250
2. 2 Contact material
2. 3 Rated insulation voltage
Switching voltage min./max.
2. 4 Limiting continuous current
Switching current min./max.
2. 5 Switching power min./max.
Switching power min./max.
2. 6 Switching capacity
to IEC/EN 60 947-5-1 AC 15
DC 13
AC V
V
A
A
VA
W
AC/DC 10 / DC 250, AC 400 (AC/DC 100 mV / 60 V)1)
2 x 5 (see operating voltage limit curve)
10mA3) / 8 (1 mA / 0,3 A)1)
3 / 2 000 (1 mVA / 7 VA)1)
3 / 200 (1 mW / 7 W) 1) (s. limit curve for arc-free operation)
AC V/A
DC V/A
NC: 230 / 1
NC: 24 / 2
NO: 230 / 3
NO: 24 / 2
2. 7 Electrical life 2)
AC 230 V 6 A cos ϕ = 1
2. 8 Switching frequency max. switching cycles / s
at 1 s On, 1 s Off
> 1 x 105 AgNi 10
10
(s. contacts service life)
switching cycles
> 2 x 105 AgCdO
2. 9 Response time / Release time
2.10 Contact force NO / NC
ms
cN
≤ 15 / ≤ 12
≥ 10 / ≥ 8
3. 0 Other
3. 1 Mechanical life
switching cycles
≥ 50 x 106
3. 2 Temperature range
°C
- 40 ... + 60 mounted without distance (Ith = 2 x 5 A)
3. 3 Degree of protection, housing
3. 4 Housing
IP40 / IP67 IEC/EN 60 529 wash proof
Thermoplast GF, PA
3. 5 Vibration resistance
10 ... 55 Hz; 0,35 mm amplitude; 5 g max. IEC/EN 60 068-2-6
3. 6 Climate resistance
40 / 060 / 04 (climate category); A/B/D IEC/EN 60 068-1
3. 8 Insolation according to IEC 60 664-1, EN 50 178
doubleandreinforcedinsulation
Rated insulation voltage
Contamination level
Overvoltage category
AC V
250
2
III
1) Values for AgNi 10-contacts + 5 µm Au
2) 10 A total current at t = 20°C and coil voltage UN
3) Typical values
All technical data in this list relate to the state at the moment of edition.
We reserve the right for technical improvements and changes at any time.
OA/ OW 5669 / 25.02.03 d
Technical data
3. 8 Test voltage
contact-coil (1 min)
contact-contact (1 min)
AC kV eff.
AC kV eff.
kV
≥ 4
≥ 4
≥ 6
Transient volt. contact-coil (1,2 - 50 µs)
Clearance and creepage distances as per IEC/EN 60 730, IEC/EN 60 335
contact-coil
contact-contact:
mm
mm
g
≥ 8
≥ 5,5
15
3. 9 Weight
Standard variants
Ordering example
O
5669.16 /
UN
DC
V
Voltage
range
Resistance
at 20°C
Ω
Design version
OA / OW
Design version
DC V
.16
461
462
463
468
464
465
466
467
.16
991
992
993
998
994
995
996
997
.12
980
981
982
987
983
984
985
986
Contact arrangement
.16 1 NC / 1 NO
.12 2 changeover contacts
.20 1 NO /1changeover contact
5
4,0...8,0
4,8...9,6
9,6...19,2
16,0...32,0
19,2...38,4
38,4...76,8
48,0...96,0
36
6
50
12
20
24
48
60
210
580
Degree of protection
A = IP 40 (solder line proof)
W = IP 67 (wash proof)
820
3 200
5 200
18 000
110 88,0...176
Characteristics
8
10
6
1,6
1,4
1,2
4
U
max.
without load
B
2
7
10
U
max.
at 8A load
6
B
4
U
U
B
N
1,0
0,8
2
AgCdO
U
min.
6
B
10
6
4
AgNi10
0
20
40
60
80°C
2
Ambient temperature
5
10
0,8
1,6
0,2 0,4 0,6
1,0 1,2 1,4
[ kVA ]
0
Switching capacity
P
Operating voltage limit curve
Contact service life (at tu = 20°C)
1,0
0,9
0,8
260
220
180
140
100
60
Contact material
AgNi
0,7
0,6
0,5
0,4
0,3
20
0
0,2
0,2
0,4
0,6
1
0,8
0,4
0,7
Switching current
2
6
8 10
0,2
4
Power factor (cos
)
I
[ A ]
Number of cycles =
Number of cycles (ohmic) x reduction factor F
safe switch-off, no standing arc
arc max. 1 switching cycle / s
Reduction factor for inductive loads
Limit curve for arc-free operation
(at tu = 20°C)
Dimensions, pin configuration, connection diagrams
Connection for basic grid divensions 2,5 mm as well as 2,54 mm according to IEC/EN 60 097 and IEC 60 326 average
Dimensions, pin configuration, connection diagrams
Connection for basic grid divensions 2,5 mm as well as 2,54 mm according to IEC/EN 60 097 and IEC 60 326 average
Accessories
34
Fixing clip
Function modul
Relay
socket
1 x 0,5
2 x 5
20,1
7,5
max. 13
max. 31,5
Relay socket ET 1415.041 ANR 0055571
with fixing clip WN 1415.902.790
Socket
ET 1415.021 ANR 0034 769
Fixing clip ET 1415.025 ANR 0034 770 Wire
Fixing clip ET 1415.026 ANR 0047 726 Plastic
Function modul ET 1415.911 ANR 0055909
- DC, with free-wheeling diode and red LED
Function modul ET 1415.912 ANR 0055910
- AC/DC with green LED
E. DOLD & SÖHNE KG • D-78114 Furtwangen
Postf. 1251 • Tel. (07723) 6540 • Fax (07723) 654356 • e-mail dold-relays@t-online.de • internet http: //www.dold.com
相关型号: