The P5150 Probe is a high impedance probe with 50X  
attenuation and a compensation range of 10 to 25 pF. The  
probe is designed for use with Tektronix TPS2000 series  
oating oscilloscopes with high input impedance (1 M ).  
The probe includes the accessories shown below.  
Crocodile clip  
Attach the clip to the banana  
end of the common lead and  
then to your circuit common.  
WARNING. Do not substitute accessories from other  
products for use with this probe. Only use the  
accessories that are included with this probe.  
Connect the probe as shown in the illustrations below.  
To avoid electric shock when using the probe or  
accessories, keep your ngers behind the nger guard  
of the probe body and away from the shaded area shown  
in the accessory illustrations below.  
Reorder Tektronix part number  
344-0461-xx  
Common spring (TACS)  
Item  
Description  
Use this accessory to limit  
aberrations on high frequency  
signals caused by common  
lead path inductance.  
Small hook tip (TASH)  
Use this tip to access test  
points in tight spaces. Screw  
the hook tip onto the probe tip  
and then clamp the hook onto  
the circuit.  
Bend the spring to reach  
nearby common connections  
(~1 in).  
Rating: 2300 V CAT I  
1000 V CAT II  
Reorder Tektronix part number  
214-5299-xx  
P5150  
500 MHz 50X High Voltage Probe  
Color bands  
Use these bands to identify  
the oscilloscope channel at the  
probe head.  
Instructions  
Compensating the Probe  
Reorder Tektronix part number  
013-0388-xx  
Due to variations in oscilloscope input characteristics,  
the low-frequency compensation of the probe may need  
adjustment after you move the probe from one oscilloscope  
channel to another.  
Large hook tip (TALH)  
Screw the hook tip onto the  
probe tip and then clamp the  
hook onto the circuit.  
1.  
Connect the probe to the oscilloscope channel that you  
plan to use for your measurements.  
Rating: 2300 V CAT I  
1000 V CAT II  
Reorder Tektronix part number  
016-1886-xx (5 pairs)  
2.  
Connect the probe to the probe compensation output  
terminals on the oscilloscope front panel.  
Adjustment tool  
WARNING. To avoid electric shock, only connect to the  
Probe Comp signal on the oscilloscope when making  
this adjustment. To avoid electric shock, only use the  
insulated adjustment tool when making compensation  
adjustments.  
Use only this insulated tool for  
compensation adjustments.  
Reorder Tektronix part number  
003-1433-xx  
Reorder Tektronix part number  
013-0389-xx  
3.  
Push AUTOSET or otherwise adjust your oscilloscope  
to display a stable waveform.  
Common leads  
(6 in and 18 in) (TACL)  
Optional Accessories  
The accessories shown below are available for the probe  
and are rated 30 V unless indicated otherwise.  
Slide the lead over the probe  
head and snap it into place.  
Connect the banana plug  
end directly to your circuit  
common, or use the crocodile  
clip included with the probe.  
Part  
number  
Accessory  
BNC to Tip Adapter,  
Unterminated  
013-0291-xx  
Reorder Tektronix part  
numbers:  
4.  
Adjust the trimmer in the probe until you see a perfectly  
Rubber Spring Tip  
206-0060-xx  
6 inch: 196-3526-xx  
18 inch: 196-3527-xx  
at-top square wave on the display. (See illustration.)  
*P071288500*  
x
071-2885-00  
Service Information  
Avoid Electric Overload. To avoid injury or re hazard, do  
not apply potential to any input, including the reference  
inputs, that varies from ground by more than the maximum  
rating for that input.  
Characteristics Description  
Performance verication and adjustment procedures  
are available on the Tektronix Web site. Go to  
www.tektronix.com/manuals and enter P5150 in the search  
eld.  
Pollution  
Degree 2  
Do not operate in environments where cond-  
uctive pollutants may be present (as dened in  
IEC 61010-1). Rated for indoor use only.  
Avoid Exposed Circuitry and Do Not Operate Without  
Covers. Do not touch exposed connections and components  
when power is present.  
Equipment Recycling. This product complies  
with the European Union’s requirements  
according to Directive 2002/96/EC on waste  
electrical and electronic equipment (WEEE).  
For more information about recycling options,  
check the Support/Service section of the  
Tektronix Web site (www.tektronix.com).  
Specications  
Table 1: Electrical and mechanical specications  
Inspect The Probe and Accessories. Before each use,  
inspect probe and accessories for damage (cuts, tears,  
defects in the probe body, accessories, cable jacket, etc.).  
Do not use if damaged.  
Bandwidth (–3 dB)  
500 MHz  
<700 ps  
3.8 pF  
System rise time (typical)  
System input capacitance  
Compensation range  
Propagation delay  
Do Not Operate in Wet/Damp Conditions.  
Do Not Operate in an Explosive Atmosphere.  
Keep Product Surfaces Clean and Dry.  
10–25 pF  
~8.7 ns  
50:1 ±1.75%  
40 M  
Safety Summary  
Table 2: Environmental specications  
Review the following safety precautions to avoid injury and  
prevent damage to this product or any products connected  
to it. To avoid potential hazards, use this product only as  
specied. Using the probe or accessories in a manner not  
specied could result in a shock or re hazard.  
Characteristics  
Description  
System attenuation accuracy  
System input resistance @DC  
Cable length  
Safety Terms and Symbols Terms in This Manual.  
These terms may appear in this manual:  
Temperature  
Operating  
0 °C to +50 °C (+32 °F to +122 °F)  
2 m  
WARNING. Warning statements identify conditions or  
practices that could result in injury or loss of life.  
Nonoperating  
–40 °C to +71 °C (–40 °F to +159.8 °F)  
Maximum input voltage  
(see Performance Graphs)  
1000 VRMS CAT II, 2500 Vpk  
Floating: 600 VRMS CAT II  
To Avoid Fire or Personal Injury  
Humidity  
For Use With TPS2000 Series Oscilloscopes Only. Do not  
oat the reference lead of this probe above the rated oat  
voltage (600 V RMS CAT II).  
Operating  
5% to 95% relative humidity (%RH) up to  
+30 °C, 5% to 75% RH above +30 °C up  
to +50 °C. Noncondensing  
CAUTION.  
Caution statements identify conditions or  
practices that could result in damage to this product or  
other property.  
Performance Graphs  
Nonoperating  
Altitude  
5% to 95% RH up to +30 °C, 5% to 75%  
RH above +30 °C up to +65 °C, 5% to  
45% RH above +65 °C up to +71 °C  
Noncondensing  
Ground-Referenced Oscilloscope Use. Do not oat the  
reference lead of this probe when using with ground  
referenced oscilloscopes (for example, DPO, MSO, and  
TDS series oscilloscopes). The reference lead must be  
connected to earth potential (0 V).  
Symbols on the Product. These symbols may appear on  
the product:  
Operating: up to 3000 m (9842 ft)  
Nonoperating: up to 15420 m (50,000 ft)  
Connect and Disconnect Properly. Connect the probe output  
to the measurement instrument before connecting the probe  
to the circuit under test. Disconnect the probe input and  
the probe reference lead from the circuit under test before  
disconnecting the probe from the measurement instrument.  
Table 3: Certications and compliances  
Contacting Tektronix  
Characteristics Description  
Web site:  
Phone:  
www.tektronix.com  
1-800-833-9200  
EC  
Compliance was demonstrated to the following  
Avoid Electric Shock. To avoid injury or loss of life, do not  
connect or disconnect probes or test leads while they are  
connected to a voltage source.  
Declaration  
of  
Conformity  
specication as listed in the Ofcial Journal  
of the European Communities: Low Voltage  
Directive 2006/95/EC: EN61010-031/A1: 2008  
Address:  
Tektronix, Inc.  
Department or name (if known)  
14200 SW Karl Braun Drive  
P.O. Box 500  
Additional  
Safety  
Standards  
IEC61010-031; IEC 61010-031/A1:2008  
Observe All Terminal Ratings. To avoid re or shock hazard,  
observe all ratings and markings on the product. Consult  
the product manual for further ratings information before  
making connections to the product.  
Beaverton, OR 97077 USA  
Measurement CAT III: Distribution-level mains, xed  
Category  
Email:  
techsupport@tektronix.com  
installation  
Avoid Electric Shock. When using probe accessories, never  
exceed the lowest rating of the probe or its accessory,  
whichever is less, including the measurement category and  
voltage rating.  
Product  
Examples  
CAT II: Local-level mains, appliances, portable  
equipment  
Warranty Information  
For warranty information, go to  
www.tektronix.com/warranty.  
CAT I: Circuits not directly connected to mains.  
Copyright © Tektronix, Inc. All rights reserved.  
www.tektronix.com  

相关型号:

P5164L-07

Standard SRAM, 8KX8, 70ns, CMOS, PDIP28, 0.600 INCH, PLASTIC, DIP-28
INTEL

P5164L-10

Standard SRAM, 8KX8, 100ns, CMOS, PDIP28, 0.600 INCH, PLASTIC, DIP-28
INTEL

P5164L-20

Standard SRAM, 8KX8, 20ns, CMOS, PDIP28
INTEL

P5164L-25

Standard SRAM, 8KX8, 25ns, CMOS, PDIP28
INTEL

P5164L-30

Standard SRAM, 8KX8, 30ns, CMOS, PDIP28
INTEL

P5164L-35

Standard SRAM, 8KX8, 35ns, CMOS, PDIP28
INTEL

P5164S-07

Standard SRAM, 8KX8, 70ns, CMOS, PDIP28, 0.600 INCH, PLASTIC, DIP-28
INTEL

P5164S-10

x8 SRAM
ETC

P5164S-12

IC,SRAM,8KX8,CMOS,DIP,28PIN,PLASTIC
INTEL

P5164SL

64K (8K x 8) CMOS SLOW STATIC RAM
INTEL

P5164SL-10

Standard SRAM, 8KX8, 100ns, CMOS, PDIP28, 0.600 INCH, PLASTIC, DIP-28
INTEL