P5150 [ETC]
The probe includes the accessories shown below.; 该探针包括如下所示的配件。![P5150](http://pdffile.icpdf.com/pdf2/p00201/img/icpdf/P5150_1132875_icpdf.jpg)
型号: | P5150 |
厂家: | ![]() |
描述: | The probe includes the accessories shown below. |
文件: | 总2页 (文件大小:343K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
![](http://public.icpdf.com/style/img/ads.jpg)
xx
Operating Information
Standard Accessories
Item
Description
The P5150 Probe is a high impedance probe with 50X
attenuation and a compensation range of 10 to 25 pF. The
probe is designed for use with Tektronix TPS2000 series
floating oscilloscopes with high input impedance (1 M Ω).
The probe includes the accessories shown below.
Crocodile clip
Attach the clip to the banana
end of the common lead and
then to your circuit common.
WARNING. Do not substitute accessories from other
products for use with this probe. Only use the
accessories that are included with this probe.
Connect the probe as shown in the illustrations below.
To avoid electric shock when using the probe or
accessories, keep your fingers behind the finger guard
of the probe body and away from the shaded area shown
in the accessory illustrations below.
Reorder Tektronix part number
344-0461-xx
Common spring (TACS)
Item
Description
Use this accessory to limit
aberrations on high frequency
signals caused by common
lead path inductance.
Small hook tip (TASH)
Use this tip to access test
points in tight spaces. Screw
the hook tip onto the probe tip
and then clamp the hook onto
the circuit.
Bend the spring to reach
nearby common connections
(~1 in).
Rating: 2300 V CAT I
1000 V CAT II
Reorder Tektronix part number
214-5299-xx
P5150
500 MHz 50X High Voltage Probe
Color bands
Use these bands to identify
the oscilloscope channel at the
probe head.
Instructions
Compensating the Probe
Reorder Tektronix part number
013-0388-xx
Due to variations in oscilloscope input characteristics,
the low-frequency compensation of the probe may need
adjustment after you move the probe from one oscilloscope
channel to another.
Large hook tip (TALH)
Screw the hook tip onto the
probe tip and then clamp the
hook onto the circuit.
1.
Connect the probe to the oscilloscope channel that you
plan to use for your measurements.
Rating: 2300 V CAT I
1000 V CAT II
Reorder Tektronix part number
016-1886-xx (5 pairs)
2.
Connect the probe to the probe compensation output
terminals on the oscilloscope front panel.
Adjustment tool
WARNING. To avoid electric shock, only connect to the
Probe Comp signal on the oscilloscope when making
this adjustment. To avoid electric shock, only use the
insulated adjustment tool when making compensation
adjustments.
Use only this insulated tool for
compensation adjustments.
Reorder Tektronix part number
003-1433-xx
Reorder Tektronix part number
013-0389-xx
3.
Push AUTOSET or otherwise adjust your oscilloscope
to display a stable waveform.
Common leads
(6 in and 18 in) (TACL)
Optional Accessories
The accessories shown below are available for the probe
and are rated ≤30 V unless indicated otherwise.
Slide the lead over the probe
head and snap it into place.
Connect the banana plug
end directly to your circuit
common, or use the crocodile
clip included with the probe.
Part
number
Accessory
BNC to Tip Adapter,
Unterminated
013-0291-xx
Reorder Tektronix part
numbers:
4.
Adjust the trimmer in the probe until you see a perfectly
Rubber Spring Tip
206-0060-xx
6 inch: 196-3526-xx
18 inch: 196-3527-xx
flat-top square wave on the display. (See illustration.)
*P071288500*
x
071-2885-00
Service Information
Avoid Electric Overload. To avoid injury or fire hazard, do
not apply potential to any input, including the reference
inputs, that varies from ground by more than the maximum
rating for that input.
Characteristics Description
Performance verification and adjustment procedures
are available on the Tektronix Web site. Go to
www.tektronix.com/manuals and enter P5150 in the search
field.
Pollution
Degree 2
Do not operate in environments where cond-
uctive pollutants may be present (as defined in
IEC 61010-1). Rated for indoor use only.
Avoid Exposed Circuitry and Do Not Operate Without
Covers. Do not touch exposed connections and components
when power is present.
Equipment Recycling. This product complies
with the European Union’s requirements
according to Directive 2002/96/EC on waste
electrical and electronic equipment (WEEE).
For more information about recycling options,
check the Support/Service section of the
Tektronix Web site (www.tektronix.com).
Specifications
Table 1: Electrical and mechanical specifications
Inspect The Probe and Accessories. Before each use,
inspect probe and accessories for damage (cuts, tears,
defects in the probe body, accessories, cable jacket, etc.).
Do not use if damaged.
Bandwidth (–3 dB)
500 MHz
<700 ps
3.8 pF
System rise time (typical)
System input capacitance
Compensation range
Propagation delay
Do Not Operate in Wet/Damp Conditions.
Do Not Operate in an Explosive Atmosphere.
Keep Product Surfaces Clean and Dry.
10–25 pF
~8.7 ns
50:1 ±1.75%
40 MΩ
Safety Summary
Table 2: Environmental specifications
Review the following safety precautions to avoid injury and
prevent damage to this product or any products connected
to it. To avoid potential hazards, use this product only as
specified. Using the probe or accessories in a manner not
specified could result in a shock or fire hazard.
Characteristics
Description
System attenuation accuracy
System input resistance @DC
Cable length
Safety Terms and Symbols Terms in This Manual.
These terms may appear in this manual:
Temperature
Operating
0 °C to +50 °C (+32 °F to +122 °F)
2 m
WARNING. Warning statements identify conditions or
practices that could result in injury or loss of life.
Nonoperating
–40 °C to +71 °C (–40 °F to +159.8 °F)
Maximum input voltage
(see Performance Graphs)
1000 VRMS CAT II, 2500 Vpk
Floating: 600 VRMS CAT II
To Avoid Fire or Personal Injury
Humidity
For Use With TPS2000 Series Oscilloscopes Only. Do not
float the reference lead of this probe above the rated float
voltage (600 V RMS CAT II).
Operating
5% to 95% relative humidity (%RH) up to
+30 °C, 5% to 75% RH above +30 °C up
to +50 °C. Noncondensing
CAUTION.
Caution statements identify conditions or
practices that could result in damage to this product or
other property.
Performance Graphs
Nonoperating
Altitude
5% to 95% RH up to +30 °C, 5% to 75%
RH above +30 °C up to +65 °C, 5% to
45% RH above +65 °C up to +71 °C
Noncondensing
Ground-Referenced Oscilloscope Use. Do not float the
reference lead of this probe when using with ground
referenced oscilloscopes (for example, DPO, MSO, and
TDS series oscilloscopes). The reference lead must be
connected to earth potential (0 V).
Symbols on the Product. These symbols may appear on
the product:
Operating: up to 3000 m (9842 ft)
Nonoperating: up to 15420 m (50,000 ft)
Connect and Disconnect Properly. Connect the probe output
to the measurement instrument before connecting the probe
to the circuit under test. Disconnect the probe input and
the probe reference lead from the circuit under test before
disconnecting the probe from the measurement instrument.
Table 3: Certifications and compliances
Contacting Tektronix
Characteristics Description
Web site:
Phone:
www.tektronix.com
1-800-833-9200
EC
Compliance was demonstrated to the following
Avoid Electric Shock. To avoid injury or loss of life, do not
connect or disconnect probes or test leads while they are
connected to a voltage source.
Declaration
of
Conformity
specification as listed in the Official Journal
of the European Communities: Low Voltage
Directive 2006/95/EC: EN61010-031/A1: 2008
Address:
Tektronix, Inc.
Department or name (if known)
14200 SW Karl Braun Drive
P.O. Box 500
Additional
Safety
Standards
IEC61010-031; IEC 61010-031/A1:2008
Observe All Terminal Ratings. To avoid fire or shock hazard,
observe all ratings and markings on the product. Consult
the product manual for further ratings information before
making connections to the product.
Beaverton, OR 97077 USA
Measurement CAT III: Distribution-level mains, fixed
Category
Email:
techsupport@tektronix.com
installation
Avoid Electric Shock. When using probe accessories, never
exceed the lowest rating of the probe or its accessory,
whichever is less, including the measurement category and
voltage rating.
Product
Examples
CAT II: Local-level mains, appliances, portable
equipment
Warranty Information
For warranty information, go to
www.tektronix.com/warranty.
CAT I: Circuits not directly connected to mains.
Copyright © Tektronix, Inc. All rights reserved.
www.tektronix.com
相关型号: