PFB01CM24 [ETC]

Monitoring Relays Frequency Monitoring; 监控继电器监测频率
PFB01CM24
型号: PFB01CM24
厂家: ETC    ETC
描述:

Monitoring Relays Frequency Monitoring
监控继电器监测频率

继电器 监控
文件: 总3页 (文件大小:112K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
Monitoring Relays  
Frequency Monitoring  
Types DFB01, PFB01  
• Over/under frequency monitoring relays  
• Measuring if power supply frequency is within set limits  
• Measure on own power supply  
• Measuring ranges  
Voltage: 24 to 240 VAC  
Frequency: 50 - 60 Hz  
• Separately adjustable upper/lower level on relative  
scale  
• Adjustable delay on alarm or on recovery (0.1 to 30 s)  
• Programmable latching or inhibit at set level  
• Output: 8 A SPDT relay N.D. or N.E. selectable  
• For mounting on DIN-rail in accordance with DIN/EN  
50 022 (DFB01) or plug-in module (PFB01)  
• 22.5 mm Euronorm housing (DFB01) or 36 mm  
plug-in module (PFB01)  
DFB01  
PFB01  
• LED indication for relay, alarm and power supply ON  
Product Description  
Ordering key  
DFB 01 C M24  
DFB01 and PFB01 are pre- even after the end of the Housing  
cise frequency monitoring alarm condition. Inhibit func- Function  
relays. The relays monitor tion can be used to avoid Type  
their own power supply from relay operation when not Item number  
24 to 240 VAC.  
desired (maintenance, tran- Output  
The advantage of using the sitions). The LED's indicate Power Supply  
latch function is that the the state of the alarm and  
relay can be kept energized the output relay.  
Type Selection  
Mounting  
Output  
Measuring range  
Supply: 24 to 240 VAC  
DIN-rail  
Plug-in  
SPDT  
SPDT  
50-60 Hz  
50-60 Hz  
DFB 01 C M24  
PFB 01 C M24  
Input Specifications  
Output Specifications  
Input  
Output  
Rated insulation voltage  
Contact ratings (AgSnO2)  
Resistive loads  
SPDT relay  
Own power supply DFB01:  
PFB01:  
A1, A2 (24 to 240 VAC)  
2, 10 (24 to 240 VAC)  
250 VAC  
µ
Measuring ranges  
Selectable by DIP-switches  
2 Hz range  
Upper level Lower level  
AC 1  
DC 12  
8A @ 250 VAC  
5 A @ 24 VDC  
2.5 A @ 250 VAC  
2.5 A @ 24 VDC  
-0.2 to +2 Hz -2 to +0.2 Hz  
50 Hz 49.8 to 52 Hz 48 to 50.2 Hz  
60 Hz 59.8 to 62 Hz 58 to 60.2 Hz  
Small inductive loads AC 15  
DC 13  
Mechanical life  
Electrical life  
30 x 106 operations  
10 Hz range  
-1 to +10 Hz -10 to +1 Hz  
49 to 60 Hz 40 to 51 Hz  
59 to 70 Hz 50 to 61 Hz  
105 operations  
50 Hz  
60 Hz  
(at 8 A, 250 V, cos ϕ = 1)  
Operating frequency  
Dielectric strength  
Dielectric voltage  
7200 operations/h  
Contact input  
DFB02  
PFB02  
Disabled  
Enabled  
Pulse width  
Terminals Z1, Z2  
Terminals 8, 9  
> 10 kΩ  
< 500 Ω  
> 500 ms  
2 kVAC (rms)  
Rated impulse withstand volt. 4 kV (1.2/50 µs)  
Hysteresis  
2 Hz range  
10 Hz range  
~ 0.05 Hz  
~ 0.25 Hz  
Specifications are subject to change without notice (12.12.05)  
1
DFB01, PFB01  
Supply Specifications  
General Specifications  
Power supply  
Overvoltage cat. III  
(IEC 60664, IEC 60038)  
Power ON delay  
Reaction time  
1 s 0.5 s  
Rated operational voltage  
Through terminals:  
DFB01: A1, A2  
(input signal variation from  
-10% to +10% or from  
+10% to -10% of the range)  
< 200 ms  
24 to 240 VAC 15%  
24 to 240 VAC 15%  
PFB01: 2,10  
Alarm ON delay  
Alarm OFF delay  
Dielectric voltage  
Supply to output  
Rated operational power  
< 200 ms  
4 kV  
4 W  
Accuracy  
(15 min warm-up time)  
200 ppm/°C  
10% on set value 50 ms  
0.02 Hz  
Temperature drift  
Delay ON alarm  
Repeatability  
Mode of Operation  
DFB01 and PFB01 monitor Example 2  
the frequency value of their (Latching mode - N.E. relay)  
own power supply.  
Indication for  
Power supply ON  
Alarm ON  
LED, green  
LED, red (flashing 2 Hz  
during delay time)  
LED, yellow  
Output relay ON  
The relay operates and the  
Environment  
Degree of protection  
Pollution degree  
Operating temperature  
Storage temperature  
yellow LED is ON as long as  
the measured frequency is  
(Non-latching mode - N.D. within the upper and lower  
IP 20  
Example 1  
3 (DFB01), 2 (PFB01)  
-20 to 60°C, R.H. < 95%  
-30 to 80°C, R.H. < 95%  
relay)  
limits.  
The relay releases and  
Housing dimensions  
DIN-rail version  
Plug-in version  
The relay operates and the latches in alarm position as  
yellow LED is ON as soon soon as the measured fre-  
as the measured frequency quency exceeds the upper  
exceeds the upper set level set level or drops below the  
or drops below the lower set lower set level for more than  
level for more than the set the set delay time. The red  
delay time. The relay releas- LED flashes until the delay  
es when the measured fre- time has expired or the  
quency comes back within measured value comes back  
the upper and lower limits. within the limits. Provided  
The red LED flashes until the that the frequency has  
delay time has expired or dropped below the upper  
the measured value falls off set level (minus hysteresis)  
22.5 x 80 x 99.5 mm  
36 x 80 x 94 mm  
Weight  
Screw terminals  
Tightening torque  
Approx. 150 g  
Max. 0.5 Nm  
acc. to IEC 60947  
Approvals  
CE-Marking  
EMC  
Immunity  
Emission  
UL, CSA  
Yes  
Electromagnetic Compatibility  
According to EN 61000-6-2  
According to EN 61000-6-3  
the limits.  
or exceeded the lower set  
level (plus hysteresis), the  
relay operates when the  
interconnections  
between  
terminals Z1, Z2 or 8, 9 are  
interrupted.  
Function/Range/Level and Time Delay Setting  
Adjust the system frequency Selection of level and time  
Setpoint range  
ON: 2 Hz  
OFF: 10 Hz  
setting DIP switch  
3 and delay:  
select the desired function  
setting the DIP switches 1, 2 Upper knob:  
and 4 as shown on the right. Setting of upper level:  
To access the DIP switches -10 to +100% of the range.  
open the grey plastic cover  
Relay working mode  
ON: Normally De-Energized  
OFF: Normally Energized  
as shown on the right.  
Centre knob:  
Setting of lower level:  
-100 to +10% of the range.  
System frequency  
ON: 60 Hz  
OFF: 50 Hz  
Lower knob:  
Setting of delay on alarm  
time: 0.1 to 30 s.  
Contact input  
ON: Lacth function enable  
OFF: Inhibit function enable  
2
Specifications are subject to change without notice (12.12.05)  
DFB01, PFB01  
Wiring Diagrams  
DFB01  
PFB01  
Operation Diagrams  
Normally energized relay - Latch function  
Dimensions  
DIN-rail  
Plug-in  
94  
90  
22.5  
99.5  
36  
28.5  
28.5  
Specifications are subject to change without notice (12.12.05)  
3

相关型号:

PFB0912DHE

92 x 92 x 38 MM SERIES
ETC

PFB0912EHE

92 x 92 x 38 MM SERIES
ETC

PFB0912GHE

92 x 92 x 38 MM SERIES
ETC

PFB0912HHE

92 x 92 x 38 MM SERIES
ETC

PFB0912SHE

92 x 92 x 38 MM SERIES
ETC

PFB0912UHE

92 x 92 x 38 MM SERIES
ETC

PFB0912VHE

92 x 92 x 38 MM SERIES
ETC

PFB0924DHE

92 x 92 x 38 MM SERIES
ETC

PFB0924EHE

92 x 92 x 38 MM SERIES
ETC

PFB0924GHE

92 x 92 x 38 MM SERIES
ETC

PFB0924UHE

92 x 92 x 38 MM SERIES
ETC

PFB0948EHE

92 x 92 x 38 MM SERIES
ETC