PH100F24-5 [ETC]
PH100F24;NNEEMMIICC--LLAAMMBBDDAA
PH100F24
SPECIFICATION
C101-01-01A
MODEL
PH100F PH100F PH100F PH100F PH100F PH100F PH100F
ITEMS
24-2
2
24-3
3
24-5
5
24-12
12
24-15
15
24-24
24
24-48
28
1 Nominal Output Voltage
2 Maximum Output Current
3 Nominal Output Power
4 Efficiency (Typ.)
V
A
W
%
-
20
40
66
20
60
70
20
8.4
6.7
4.2
3.6
100
80
100.8
81
100.5
82
100.8
83
100.8
83
(*1)
5 Input Voltage Range
6 Input Current (Typ.)
7 Output Voltage Accuracy
8 Output Voltage Range
9 Maximum Ripple & Noise
10 Maximum Line Regulation
11 Maximum Load Regulation
12 Over Current Protection
13 Over Voltage Protection
14 Remote Sensing
18 ~ 36VDC
5.19
(*1)
(*1)
A
-
2.53
3.57
5.21
5.11
5.06
5.06
1%
20%
(*10)
-
+20%, -60%
(*9) mV
(*2) mV
(*3) mV
100
20
100
20
100
20
150
48
150
60
240
96
280
112
224
40
40
40
96
120
192
(*4)
(*5)
(*8)
(*8)
(*8)
(*8)
(*8)
(*6)
A
105% ~ 140%
125% ~ 145%
Possible
V
165% ~ 240%
-
15 Remote ON/OFF Control
16 Parallel Operation
-
Possible (SHORT:ON OPEN:OFF)
Possible
-
17 Series Operation
-
Possible
18 I.O.G. Signal
-
Possible (Open Collector Output)
19 Operating Temperature
20 Operating Humidity
21 Storage Temperature
22 Storage Humidity
-
- 20°C ~ + 85°C (Base plate) Ambient Temperature MIN = - 20°C.
30 - 95%RH (No Dewdrop)
-
-
- 40°C ~ + 85°C
-
10 - 95%RH (No Dewdrop)
23 Cooling
(*7)
-
Conduction Cooled
24 Temperature Coefficient (%)
25 Withstand Voltage
-
0.02% / °C
-
Input-Baseplate : 2kVAC, Input-Output : 2kVAC(20mA) for 1min
Output-Baseplate : 500VDC(100mA) for 1min
More than 100Mohm at 25°C and 70%RH Output-Baseplate...500VDC
At No Operating, 10-55Hz (Sweep for 1min)
Amplitude 0.825mm Constant (Maximum 49.0m/s2) X,Y,Z 1h each
196.1m/s2 (In package)
-
26 Isolation Resistance
27 Vibration
-
-
-
-
28 Shock
29 Weight (Typ.)
30 Size (W x H x D)
-
180g
mm
83 x 12.7 x 86 (Refer to Outline Drawing)
=NOTES=
*DERATING CURVE*
*1. At 24VDC and Maximum Output Current.
*2. 18 ~ 36VDC, Constant Load.
100
80
60
40
20
0
*3. No load ~ Full load, Constant input voltage.
*4. Constant current limiting with automatic recovery.
*5. Inverter shutdown method, Manual Reset.
*6. Ratings - Refer to Derating Curve on the Right.
- Load(%) is Percent of Maximum Output
Current.
*7. Heatsink has to be Chosen According to Instruction
Manual.
*8. Refer to Instruction Manual.
*9 External Components are Needed for Operation.
(Refer to Basical Connection and Instruction Manual)
*10 At 24VDC Input.(Refer to Instruction Manual.)
-20
0
20 40 60 100
85
Baseplate (°C)
相关型号: