T H U R L B Y T H A N D A R I N S T R U M E N T S  
PL & PL-P Series  
Laboratory Power Supplies  
Standard and Programmable models, 35 watts to 240 watts  
Thurlby Thandar PL series  
the Premier range of laboratory power supplies  
Precision with convenience  
The Thurlby Thandar PL series of labo-  
With the output switch “off” the the cur-  
Greater resolution and  
control  
The PL series sets the standard for sim-  
ple and comprehensive control. Voltages  
are set with coarse and fine controls for  
speed with precision. Currents are set with  
a semi-logarithmic control for increased  
resolution at low current levels.  
ratory bench power supplies has estab-  
lished itself in many countries as the  
“premier” range.  
rent limit set point is displayed. With the  
output switch “on” the actual output cur-  
rent flowing is displayed.  
High resolution controls enable precise  
setting of voltage and current levels  
whilst high accuracy digital meters pro-  
vide clear, unambiguous readings.  
This invaluable feature allows delicate  
circuits to be protected by accurately set-  
ting the current limit level (down to a few  
milliamps if necessary) before connecting  
the circuit under test.  
All of the many features of these PSUs  
have been carefully designed to give the  
user not just greater precision, but  
greater clarity, more control and unri-  
valled ease of use.  
The DC output switch enables voltage  
and current levels to be set before the  
load is connected.  
The range has now been improved and  
extended to offer even better perform-  
ance and choice.  
Digital accuracy and  
convenience  
PL series units incorporate digital meters  
with a 3.75 digit scale length (4095  
counts) to provide greater accuracy and  
resolution than other PSUs.  
Large and bright LEDs give a clear and  
unambiguous reading. An update rate of  
4 per second provides near instantane-  
ous response.  
Separate meters are used for voltage  
and current, eliminating the need for me-  
ter function switches with their attendant  
problems of misinterpretation.  
A damping switch for the current meter  
simplifies measurements on rapidly vary-  
ing loads.  
Remote sense for  
precision at high currents  
PL series units incorporate integrated  
band-gap reference diodes as the basis  
for stabilisation of both voltage and cur-  
rent.  
Simultaneous digital metering of voltage and current.  
True constant voltage or constant current operation.  
Twin 3.75 digit meters with large LED displays.  
0.1% accuracy; 0.01 Volts and 0.001 Amps resolution.  
Excellent stability, resolution and setting accuracy.  
DC output switches, automatic mode indication.  
Precise control and monitoring of current limit settings.  
Remote sense facility for high-current precision.  
Current meter damping switch for fluctuating currents.  
Parallel and tracking modes on QMD & QMT models.  
High current “logic supply” output on QMT models.  
Remote sense terminals enable the pre-  
cision to be maintained at high currents  
by eliminating the effects of connection  
lead resistance.  
Without remote sense lead resistance of  
just a few tens of milliohms can seriously  
degrade regulation and produce mis-  
leading results. (Two cables of 0.05  
each will drop a total of 0.3V at 3 Amps.)  
Quad-Mode Dual versions  
The 32V-1A, 32V-2A and 32V-3A sup-  
plies are each available as a dual unit in-  
corporating push button selection of four  
different modes of operation.  
Safety and protection  
PL series PSUs are designed and built to  
meet the stringent requirements of  
IEC348 and IEC1010.  
All outputs are fully protected against  
short circuit, reverse voltage and reverse  
currents.  
Isolated  
Completely independent operation of  
each supply.  
True Parallel  
Converts the Master unit into a 2 Amp,  
4 Amp or 6 Amp supply respectively.  
Series Tracking  
Series  
The Master unit voltage control sets up  
equal voltages on both supplies.  
Internal linking of the two supplies pro-  
viding up to 64 Volts.  
Quad Mode Triple versions  
Each of the quad-mode dual models is al-  
ternatively available as a triple supply in-  
corporating one further independent  
output.  
PL330QMT  
A wide range of models  
Variable output voltage (4V to 6V) and  
variable current limit (0.1A to 7A).  
The PL series includes single, dual and  
triple output models from 35 Watts up to  
240 Watts.  
Digital meter for current measurement  
and voltage setting.  
This is a higher current 5 Volt output in-  
tended for powering logic circuits.  
See the model selector guide for a sum-  
mary of voltage and current combinations.  
Remote sense terminals, DC output  
switch, over-voltage trip.  
The current rating and sophistication of  
the logic output varies according to the  
model as follows:  
The PL series is part of a wider range of  
bench PSUs from Thurlby Thandar  
which includes models with current ca-  
pabilities up to 20 Amps.  
PL310QMT  
Fixed 5V supply at 1.5A maximum.  
Full short-circuit protection.  
PL320QMT  
Variable output voltage (4V to 6V) and  
variable current limit (0.1A to 4A).  
Calibrated voltage control.  
Remote sense terminals, DC output  
switch, over-voltage trip.  
Thurlby Thandar PL-P series  
programmable power at surprisingly low cost  
PL-P series  
The Thurlby Thandar PL-P series offers  
a high performance fully programmable  
power supply system at low cost.  
Simple and consistent  
control  
PL-P series supplies use simple and  
consistent command structures which  
make programming particularly easy re-  
gardless of which interface is used.  
Based around the 32V-3A versions of the  
standard PL series, the PL-P models in-  
clude single, dual and triple output units  
suitable for bench or rack mounting.  
is exclusive to Thurlby-Thandar instru-  
ments.  
It differs from conventional RS-232 in  
that it allows multiple instruments (up to  
32) to be controlled using the normal  
RS-232 or RS-422/423 port of a PC.  
A National Instruments LabWindows*  
device driver is available as an option.  
When not connected to the bus, these  
PSUs can be operated exactly as a stan-  
dard PL series PSU.  
ARC provides a low-cost alternative to  
GPIB which utilises lower cost instru-  
ments, inexpensive cables, and can be  
controlled by any personal computer  
without the need for a special interface  
card or special software.  
ARC, an exclusive Thurlby  
Thandar innovation  
ARC stands for “Addressable RS-232  
Chain” and is a low-cost system for link-  
ing instruments together so that they can  
be controlled and monitored by a per-  
sonal computer.  
GPIB and RS-232 (ARC)  
interfaces  
Each PL-P series supply is fitted with  
both a GPIB (IEEE-488) interface and an  
ARC (addressable RS232) interface as  
standard.  
* LabWindows is a trademark of National  
Instruments Corporation.  
The ARC interface is an extension of the  
industry standard RS-232 interface and  
Both interfaces provide full bus control of  
voltage and current settings along with  
full readback of actual current and volt-  
age levels.  
The GPIB interface conforms fully with  
IEEE-488.2 as well as IEEE-488.1. The  
ARC interface can be used as a conven-  
tional RS-232 interface or as part of a  
multi-instrument ARC system.  
On dual and triple output models a single  
bus address controls all outputs.  
Fully isolated outputs for  
maximum flexibility  
Each output is fully floating and is opto-  
isolated from the bus interfaces.  
Outputs can be linked in series or parallel  
to produce higher voltages or higher cur-  
rents as required.  
High resolution control  
and readback  
Full bus control and readback of voltage and current.  
GPIB interface conforms to IEEE-488.2.  
Voltage and current levels can be set via  
the bus to a resolution of 10mV and 1mA  
for each main output.  
ARC (Addressable RS-232) interface for low-cost  
PC based control.  
The 7 Amp logic output of the PL330TP  
can also be set to a resolution of 10mV  
but the current control resolution is lim-  
ited to 1 Amp steps.  
Can be operated as a conventional bench PSU.  
Single, dual and triple output models available.  
Each main output can be read back via  
the bus to a resolution of 10mV and  
1mA.  
Triple output model incorporates fully controllable  
high current logic output.  
Rack mounting kit (4U) available for all models.  
Technical Specifications  
MODEL SELECTOR GUIDE  
MAIN OUTPUT(S)  
Output Range:  
0 - 32 Volts nominal; 0 - 15.5V (PL154).  
0 - 1.1A nominal (PL310);  
0 - 2.1A nominal (PL320);  
0 - 3.1A nominal (PL330);  
0 - 4A nominal (PL154).  
MODEL  
MAIN OUTPUT(S)  
LOGIC  
OUTPUT  
INTERFACES  
GPIB  
ARC  
PL310  
PL320  
PL154  
PL330  
0 - 32V at 0 - 1A  
0 - 32V at 0 - 2A  
0 - 15.5V at 0 - 4A  
0 - 32V at 0 - 3A  
Output Voltage  
Setting:  
Output Current  
Setting:  
By coarse and fine controls; resolution better than 5mV  
across the range.  
By single logarithmic control.  
Output Mode:  
The power supply operates in constant current or constant  
voltage modes with automatic cross-over. Decimal points  
flash to indicate constant current mode.  
Isolated, True parallel, Series or Series Tracking via front  
panel switches.  
Configuration  
Selection:  
(QMD and QMT only)  
Output Switch:  
PL310QMD 2 x 0 - 32V at 0 - 1A  
or 0 - 32V at 0 - 2A  
Isolates the output and permits voltage and current limits to  
be set up before connecting the load.  
or 0 - 64V at 0 - 1A  
Output Terminals:  
Output Impedance:  
4mm terminals on 19mm (0.75") spacing.  
Constant Voltage: Typically <5mat 1kHz  
Constant Current: Typically 50kwith voltage limit at maxi-  
mum  
Up to maximum output voltage +20 Volts forward; diode  
clamped for reverse voltages and up to 3A reverse current.  
<0.01% of maximum output for 90% load change  
<0.01% of maximum output for 10% line voltage change  
Eliminates up to 0.5V drop per lead.  
or 0 - ±32V at 0 - 1A  
PL320QMD 2 x 0 - 32V at 0 - 2A  
or 0 - 32V at 0 - 4A  
Output Protection:  
or 0 - 64V at 0 - 2A  
Load Regulation:  
Line Regulation:  
Remote Sense:  
Ripple and Noise:  
or 0 - ±32V at 0 - 2A  
PL330QMD 2 x 0 - 32V at 0 - 3A  
or 0 - 32V at 0 - 6A  
Typically <1mV rms  
Transient Response: <20usec to within 50mV of setting for 90% load change  
Temperature  
Coefficient:  
Meter Type:  
Typically <100ppm/oC  
or 0 - 64V at 0 - 3A  
Dual 3.75 digit (4095 count) with 12.5mm (0.5") LEDS,  
(scale length increased to 8190 on PL330QMD/QMT).  
Reading rate 4 per second.  
Voltage: 10mV over the entire range  
Current: 1mA over the entire range  
Voltage: ±(0.1% of reading + 1 digit)  
Current: ±(0.3% of reading + 1 digit)  
Nominally 20ms switchable to 2 sec for averaging of rapidly  
varying loads  
or 0 - ±32V at 0 - 3A  
PL310QMT 2 x 0 - 32V at 0 - 1A  
or 0 - 32V at 0 - 2A  
Meter Resolution:  
Meter Accuracy:  
5V at 1.5A  
or 0 - 64V at 0 - 1A  
Current Meter  
Damping:  
or 0 - ±32V at 0 - 1A  
PL320QMT 2 x 0 - 32V at 0 - 2A  
or 0 - 32V at 0 - 4A  
LOGIC OUTPUT - PL310QMT  
4 - 6V at  
0.1 - 4A  
Output Voltage:  
Fixed 5 V ± 0 1 V.  
Max.Output Current:  
Output Terminal:  
Output Protection:  
>1 5 Amps.  
4mm terminals on 19mm (0 75") spacing.  
Output will withstand up to 16 V forward voltage. Diode  
clamped for reverse voltages and up to 3 Amps reverse cur-  
rent.  
or 0 - 64V at 0 - 2A  
or 0 - ±32V at 0 - 2A  
PL330QMT 2 x 0 - 32V at 0 - 3A  
or 0 - 32V at 0 - 6A  
Load Regulation:  
Line Regulation:  
< 0 3% for 50% load change.  
< 0 1% for 10% line change.  
4 - 6V at  
0.1 - 7A  
LOGIC OUTPUT - PL320QMT  
Output Voltage  
or 0 - 64V at 0 - 3A  
Range:  
Output Current:  
Output Switch:  
4 to 6 Volts  
0.1 to 4 Amps.  
or 0 - ±32V at 0 - 3A  
Isolates the output and permits output voltage to be set bef-  
ore connecting the load.  
4mm terminals on 19mm (0.75") spacing.  
PL330P  
PL330DP  
PL330TP  
0 - 32V at 0 - 3A  
Yes  
Yes  
Yes  
Yes  
Yes  
2 x 0 - 32V at 0 - 3A  
Output Terminals:  
Over-Voltage  
Protection:  
2 x 0 - 32V at 0 - 3A 4 - 6V at 1 - 7A Yes  
Above 7 Volts  
Output Protection:  
Clamped by the over-voltage protection circuit for forward  
voltages over 7 Volts and up to 1 Amp forward current. Diode  
clamped for reverse voltages and up to 3 Amps reverse cur-  
rent.  
Load Regulation:  
Line Regulation:  
Remote Sense:  
Ripple and Noise:  
<0.01% of maximum output for 90% load change  
<0.01% of maximum output for 10% line voltage change  
Eliminates up to 0.5V drop per lead.  
Typically <1mV rms  
Transient Response: <20usec to within 50mV of setting for 90% load change  
Temperature  
Coefficient:  
Voltage Setting  
Accuracy:  
Typically <100ppm/oC  
Models illustrated within this brochure:-  
Front cover - PL330, PL320QMD, PL310QMT  
Inside pages - PL330QMT, PL330DP  
± 0.1V  
Technical Specifications continued  
LOGIC OUTPUT - PL330QMT & PL330TP  
REMOTE CONTROL INTERFACES - PL-P MODELS  
Both interfaces feature full control, readback and status reporting.  
Output Voltage  
Range:  
4 to 6 Volts  
RS232:  
Variable Baud rate (9600 maximum), 9 pin D-connector (fe-  
male). Fully compatible with ARC (Addressable RS232  
Chain) system.  
Output Current:  
Output Switch:  
0.1 to 7 Amps.  
Isolates the output and permits output voltage to be set bef-  
ore connecting the load.  
GPIB:  
Conforming with IEEE-488.1 and IEEE-488.2  
Output Terminals:  
Over-Voltage  
Protection:  
4mm terminals on 19mm (0.75") spacing.  
Address Selection: By rear panel DIP switch.  
Remote/Local  
Above 7 Volts  
Operation:  
Selected by front panel switch.  
Output Protection:  
Clamped by the over-voltage protection circuit for forward  
voltages over 7 Volts and up to 1 Amp forward current. Di-  
ode clamped for reverse voltages and up to 3 Amps reverse  
current.  
Remote Command Response Time:  
Interface:  
<15 ms (single command, input buffer empty).  
Output Voltage - Up:Time constant typically 2ms, e.g. 10ms to settle within 1%  
of a step change, 15ms to settle within 0.1%.  
Output Voltage - DowTni:me constant determined by the discharge of the power  
supply output capacitor (47uF). Typically <10ms to settle  
within 1% for a 10V step change at 50mA load current; typi-  
cally <200ms to settle within 1% at zero load.  
Load Regulation:  
Line Regulation:  
Remote Sense:  
Ripple and Noise:  
<0.01% of maximum output for 90% load change  
<0.01% of maximum output for 10% line voltage change  
Eliminates up to 0.5V drop per lead.  
Typically <1mV rms  
Transient Response: <20usec to within 50mV of setting for 90% load change  
Temperature  
Output Current:  
Typically 50ms to settle within 10mA for a 1A change.  
Coefficient:  
Meter Type:  
Typically <100ppm/oC  
3.75 digit (4095 count) with 12.5mm (0.5") LEDs. Reading  
rate 4 per second.  
GENERAL  
Power Requirements:  
Input Voltage:  
Internally set for 110, 120, 220 or 240VAC 50/60Hz  
Meter Resolution:  
Voltage: 10mV  
Input Voltage Range:  
Power Consumption:  
±10% of voltage setting  
Single Dual  
75VA 150VA 300VA  
15V/4A & 30V/2A150VA 300VA 450VA  
30V/3A 225VA 450VA 600VA  
Current: 10mA  
Meter Accuracy:  
Triple  
30V/1A  
Voltage: ±(0.2% of reading + 1 digit )  
Current: ±(0.5% of reading + 1 digit )  
Environmental:  
Weight:  
Operating Range: 5oC to 40oC, 20% to 80% RH  
Storage Range: -20oC to +60oC  
PL-P MODELS, ADDITIONAL SPECIFICATIONS  
Remote programmable versions in the range feature full control, read back and  
status reporting via the GPIB and RS232 interfaces. The GPIB interface con-  
forms to the IEEE 488.1 and 488.2 standards and the RS232 interface is fully  
compatible with the Thurlby-Thandar Addressable RS232 Chain (ARC) standard.  
8 rear panel DIP switches are used to specify baud rate, bus address and active  
interface (GPIB or RS232). Remote/Local operation is selected by a front panel  
switch.  
Single Dual  
Triple  
30V/1A PL  
15V/4A PL  
30V/2A PL  
30V/3A PL  
30V/3A PL-P  
4.0kg 8.0kg 11.5kg  
5.0kg  
5.0kg 9.5kg 13.5kg  
6.0kg 12.0kg 15.5kg  
6.5kg 12.5kg 16.0kg  
LOCAL OPERATION  
Size:  
PL310, PL154, &  
PL320:  
PL330:  
PL330P:  
For a programmable instrument operated in local state, all capabilities and speci-  
fications remain unchanged from those of a standard instrument .  
REMOTE OPERATION  
With the instrument switched to the remote state, all voltage and current adjust-  
ment controls become inoperative and commands received over the active inter-  
face will be parsed and executed.  
155mm(W) x 170mm(H) x 265mm(D)  
155mm(W) x 170mm(H) x 300mm(D)  
207mm(W) x 170mm(H) x 300mm(D)  
PL310QMD, PL310QMT, &  
PL320QMD:  
PL330QMD, &  
PL330DP:  
PL320QMT:  
PL330QMT, &  
PL330TP:  
350mm(W) x 170mm(H) x 265mm(D)  
MAIN OUTPUT(S) - REMOTE OPERATION  
350mm(W) x 170mm(H) x 300mm(D)  
425mm(W) x 170mm(H) x 265mm(D)  
Output Voltage  
Setting:  
12 bit resolution (10mV steps)  
Output Current  
Setting:  
425mm(W) x 170mm(H) x 300mm(D)  
12 bit resolution (1mA steps)  
Rack Mount Option: 19 inch 4U mount for two PL330P or one PL330DP/TP.  
Anti-tamper cover for security.  
Setting Accuracy:  
Voltage: ±(0.1% + 10mV)  
Current: ±(0.2% + 2mA)  
Electronic by interface command (front panel output  
switches must be set to ON)  
Electrical Safety:  
Designed and manufactured to comply with IEC 348 and  
IEC1010-1. Full safety sockets available to special order.  
Designed and manufactured to comply with EN50081–1  
and EN50082–1.  
Output Switch:  
EMC:  
Readback Resolution:Voltage: 10mV over the entire range  
Current: 1mA over the entire range  
Readback Accuracy:  
Voltage: ±(0.1% of reading + 1 digit)  
Current: ±(0.3% of reading + 1 digit)  
Nominally 20ms switchable to 2 sec and back by remote  
commands  
Current Meter  
Damping:  
LOGIC OUTPUT (PL330TP) - REMOTE OPERATION  
Output Voltage  
Range:  
4 to 6 Volts in 10mV steps  
Output Current:  
Setting Accuracy:  
Output Switch:  
1 to 7 Amps in approximate 1A steps  
Voltage: ±(0.2% + 10mV)  
Electronic by interface command (front panel output switch  
must be set to ON)  
Readback Resolution:Current: 10mA  
Readback Accuracy:  
Current: ±(0.5% of reading + 1 digit )  
Thurlby Thandar Instruments Ltd. operates a policy of continuous development and  
reserves the right to alter specifications without prior notice.  
Designed and built in the U.K. by:  
Thurlby Thandar Instruments Ltd.  
Glebe Road, Huntingdon. Cambs. PE18 7DX England  
Tel: 01480 412451 Fax: 01480 450409 e-mail: sales@ttinst.co.uk  
82100-0046  

相关型号:

PL321-1A02-1

Visible LED
P-TEC

PL321-1A02-1-5V

Visible LED
P-TEC

PL321-1A02-2-24V

Visible LED
P-TEC

PL321-1A022

Visible LED
P-TEC

PL321-1G13

3mm LED Panel Mount Metal Holder
P-TEC

PL321-1G13-1-LC

Visible LED
P-TEC

PL321-1G13-2

3mm LED Panel Mount Metal Holder
P-TEC

PL321-1G13B12BSH12

Panel Mount Indicator with Outer Reflector
P-TEC

PL321-1G13B12BSH12_14

Panel Mount Indicator with Outer Reflector
P-TEC

PL321-1O12

Visible LED
P-TEC

PL321-1O122

Visible LED
P-TEC

PL321-1R12

3mm LED Panel Mount Metal Holder
P-TEC