PP001108 [ETC]

High Temperature Silicone Wire SIAF/GL;
PP001108
型号: PP001108
厂家: ETC    ETC
描述:

High Temperature Silicone Wire SIAF/GL

文件: 总3页 (文件大小:281K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
High Temperature  
Silicone Wire SIAF/GL  
Application:  
Designed for use in environments where sustained heat resistance and continued function is required during a fire. They have  
heat resistant properties up to 180°C and can also be employed at temperatures as low as -60°C. These wires are low smoke  
zero halogen and are particularly suitable for power plants, a wide range of industrial applications in processing, packaging,  
refrigeration, foundaries, air craft construction and ship building .  
Construction:  
Conductor:  
SIAF/GL - Class 5 flexible tinnned copper conductor according to BS EN 60228 (previously BS 6360)  
Insulation:  
Silicone rubber  
Outer Covering:  
Fibre Glass Braid  
Cable Standards  
Made in accordance with the following:  
Generally to BS EN 50525-2-41  
Characteristics:  
Voltage Rating (Uo/U)  
0.75mm2 and above : 300/500V  
Temperature Rating:  
Fixed: -60°C to +180°C  
Min. Bending Radius:  
Fixed  
: 4 x overall diamater  
Sheath Colour:  
Black, Blue, Red & White  
www.element14.com  
www.farnell.com  
www.newark.com  
www.cpc.co.uk  
Page <1>  
23/09/15 V1.1  
High Temperature  
Silicone Wire SIAF/GL  
Dimensions:  
Flexible Core Silicone Rubber Insulated Cable / Fibre Glass Braid (SIAF/GL)  
Nominal Cross Nominal Thickness Nominal Overall  
Nominal  
Weight  
kg/km  
No. of  
Cores  
Part Number Colour  
Sectional Area  
mm²  
of Insulation  
mm  
Diameter  
mm  
PP001104  
PP001105  
PP001106  
PP001107  
PP001108  
PP001109  
PP001110  
PP001111  
PP001112  
PP001113  
PP001114  
PP001115  
Black  
Blue  
0.75  
2.4  
2.6  
2.9  
14  
17  
22  
Red  
White  
Black  
Blue  
1
1
0.55  
Red  
White  
Black  
Blue  
1.5  
Red  
White  
Conductors  
Class 5 Flexible Copper Conductors for Single Core Cables  
Max. Resistance of Conductor at 20°C  
Nominal Cross  
Sectional Area  
mm²  
Max. Diameter of  
Wires in Conductor  
mm  
Plain Wires  
Metal-Coated Wires  
Ω/km  
Ω/km  
0.75  
1
0.21  
0.21  
0.26  
26  
26.7  
20  
19.5  
13.3  
1.5  
13.7  
The above table is in accordance with BS EN 60228 (previously BS 6360)  
Electrical Characteristics:  
Flexible Core Silicone Rubber Insulated Cable / Fibre Glass Braid (SIAF/GL)  
Current Rating in Air  
Amps  
Nominal Cross  
Sectional Area  
mm²  
at 30°C  
30  
at 60°C  
26  
at 90°C  
22  
at 120°C  
at 150°C  
at 170°C  
0.75  
1
17  
20  
25  
11  
13  
17  
6
7
8
35  
31  
26  
1.5  
44  
38  
52  
Conductor operating temperature 180°C  
www.element14.com  
www.farnell.com  
www.newark.com  
www.cpc.co.uk  
Page <2>  
23/09/15 V1.1  
High Temperature  
Silicone Wire SIAF/GL  
Part Number Table  
Nominal Cross  
Sectional Area  
mm²  
Description  
Colour  
Reel Length Part Number  
Black  
Blue  
PP001104  
PP001105  
PP001106  
PP001107  
PP001108  
0.75  
Red  
White  
Black  
Blue  
PP001109  
100m  
High Temperature Silicone Wire  
1
SIAF/GL  
Red  
PP001110  
White  
Black  
Blue  
PP001111  
PP001112  
PP001113  
PP001114  
PP001115  
1.5  
Red  
White  
Important Notice : This data sheet and its contents (the “Information”) belong to the members of the Premier Farnell group of companies (the “Group”) or are licensed to it. No licence is granted  
for the use of it other than for information purposes in connection with the products to which it relates. No licence of any intellectual property rights is granted. The Information is subject to change  
without notice and replaces all data sheets previously supplied. The Information supplied is believed to be accurate but the Group assumes no responsibility for its accuracy or completeness, any  
error in or omission from it or for any use made of it. Users of this data sheet should check for themselves the Information and the suitability of the products for their purpose and not make any  
assumptions based on information included or omitted. Liability for loss or damage resulting from any reliance on the Information or use of it (including liability resulting from negligence or where the  
Group was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict the Group’s liability for death or personal injury resulting from its negligence.  
pro-POWER is the registered trademark of the Group. © Premier Farnell plc 2012.  
www.element14.com  
www.farnell.com  
www.newark.com  
www.cpc.co.uk  
Page <3>  
23/09/15 V1.1  

相关型号:

PP001109

High Temperature Silicone Wire SIAF/GL
ETC

PP001110

High Temperature Silicone Wire SIAF/GL
ETC

PP001111

High Temperature Silicone Wire SIAF/GL
ETC

PP001112

High Temperature Silicone Wire SIAF/GL
ETC

PP001113

High Temperature Silicone Wire SIAF/GL
ETC

PP001114

High Temperature Silicone Wire SIAF/GL
ETC

PP001115

High Temperature Silicone Wire SIAF/GL
ETC

PP001185

Tri-Rated Flexible PVC Equipment Wire
ETC

PP001186

Tri-Rated Flexible PVC Equipment Wire
ETC

PP001187

Tri-Rated Flexible PVC Equipment Wire
ETC

PP001188

Tri-Rated Flexible PVC Equipment Wire
ETC

PP001189

Tri-Rated Flexible PVC Equipment Wire
ETC