PR-21SR/80427.35-2.5 [ETC]

TRANSMITTER PIEZORESITIV ; 变送器PIEZORESITIV\n
PR-21SR/80427.35-2.5
型号: PR-21SR/80427.35-2.5
厂家: ETC    ETC
描述:

TRANSMITTER PIEZORESITIV
变送器PIEZORESITIV\n

文件: 总2页 (文件大小:80K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
KELLER  
PIEZORESISTIVE TRANSMITTERS AND TRANSDUCERS  
INDUSTRIAL APPLICATIONS. ABSOLUTE AND GAUGE REFERENCES.  
SERIES 21 R  
This new range of KELLER OEM pressure transmitters and transducers offers the user the  
high accuracy and stability of the KELLER piezoresistive pressure capsule in a low cost OEM  
package. Applications include refridgeration, hydraulic controls, air compressors, ink jet printers,  
vacuum pumps etc.  
The silicon sensor is mounted in an all welded oil filled stainless steel capsule, providing a  
highly stable measuring cell with negligible hysteresis, unrivalled linearity, high output and a  
life of millions of pressure cycles.  
The Series 21R use the Series 6 capsule, which is of all welded 316L stainless steel construc-  
tion. Transducers are supplied with 2 metres of screened cable, or a square connector and  
mating plug, type mPm-193.  
Accuracy is achieved by very large scale predictable production quantities of the pressure  
capsule (over 2 million produced today).  
Reliability is assured by the inherent properties of the perfectly elastic silicon chip, and ensuring  
that neither the pressure media nor the reference media (in the gauge version) come into  
contact with any sensitive parts.  
Temperature Compensation: Each unit is fully tested and compensated. Span errors are  
reduced by selecting the semiconductor doping levels so that the gauge factor of the strain  
gauges (R) is constant with temperature. Thermal zero compensation is achieved by an  
automatic test procedure which fits a single resistor across one arm of the bridge.  
Shock and vibration performance is excellent due to the silicon chip being suspended in the  
oil-filled capsule. It is isolated mechanically from the body. Similarly, the effects of mounting  
torque are eliminated.  
SERIES 21R WITH CABLE  
(PLAN 80096.2)  
ELECTRICAL CONNECTIONS  
2-WIRE 3-WIRE  
4-WIRE  
G 1/4"  
GREEN  
GND  
+OUT  
+VCC  
GND (WHITE)  
+OUT (RED)  
+VCC (BLACK)  
-OUT (BLUE)  
ø 17  
WHITE OUT/GND  
BROWN +VCC  
Cable Connection  
ø 18,6  
~ 50  
HEX 19  
HEX 19  
2-WIRE  
3-WIRE  
4-WIRE  
SERIES 21R WITH PLUG  
(PLAN 80096.3)  
mPm-Connector  
(Contact Spacing 9,4 mm)  
1
2
3
4
OUT/GND  
GND  
+OUT  
+VCC  
GND  
+OUT  
+VCC  
-OUT  
G 1/4"  
+VCC  
ø 17  
12  
8
~ 56  
Subject to alterations  
4/99  
KELLER AG für Druckmesstechnik  
KELLER Gesellschaft für druckmesstechnik mbH  
St. Gallerstrasse 119  
Schwarzwaldstrasse 17  
CH-8404 Winterthur  
D-79798 Jestetten  
Tel. 052 - 235 25 25  
Tel. 07745 - 9214 - 0  
Fax 052 - 235 25 00  
Fax 07745 - 9214 - 50  
Companies approved to ISO 9001 / EN 29001  
Internet: http://www.keller-druck.ch  
druckmesstechnik  
KELLER  
SPECIFICATIONS  
SERIES 21 R  
PR 21 R *  
PAA 21 R  
PA 21 R  
0,5  
1,0  
1,0  
1,0  
2,5  
1,6  
1,6  
1,6  
3
2,5  
2,5  
2,5  
6
6
6
6
8
10  
10  
10  
15  
16  
16  
16  
25  
bar vented gauge  
bar absolute  
25  
60  
50  
75  
100  
150  
160  
250  
250 400 600 bar sealed gauge  
600 600 800 bar  
Over Range  
2
* mPm connector only, not cable  
Transmitter  
Transducer  
Signal Output  
4…20 mA  
0…5 Vdc  
1…6 Vdc  
0…10 Vdc  
0…100 mV  
Supply Voltage  
8…28 Vdc  
13…30 Vdc  
8…28 Vdc.  
10 Vdc  
Current required  
Zero/Span Tolerance  
Configuration  
up to 20 mA  
1% FS  
4 mA max.  
1% FS  
2 mA max.  
1% FS**  
1% FS**  
±0,1% FS  
4 wire  
2 wire  
3 wire  
Electrical Connection:  
mPm 193 micro or  
cable 2m, 4 core  
OUT/GND: Pin 1 / White  
GND:  
+OUT: Pin 2 / White  
+Vcc: Pin 3 / Brown  
Pin 1 / Green  
GND: Pin 1 / White  
+OUT: Pin 2 / Red  
+Vcc: Pin 3 / Black  
-OUT: Pin 4 / Blue  
0,2% typ. / 0,5% max.  
+Vcc: Pin 3 / Brown  
Linearity  
0,2 % typ. / 0,5% max.  
1% max. / 0,5% typ.  
Total Error Band*  
+18…+22°C  
0,5% max.  
1,0% max.  
2,5% max.  
Total Error Band*  
0…+50°C  
2% max. / 1,0% typ.  
4% max. / 2,5% typ.  
Total Error Band*  
-20…+80°C  
* Total error band includes linearity, hysteresis, zero and span offsets, temperature effects and repeatability.  
**Signal at zero 50 mV --> see chart  
Signal at zero for 05 V (010 V) transmitters  
5V/10V  
50 mV  
FS  
1%FS  
Maximum Temperature  
Pressure Port  
-20…+80°C (on demand -40…100°C)  
G 1/4 male parallel to ISO 228 (1/4”BSP)  
Compatible with 316L stainless steel  
75 gramme  
Pressure Media  
Weight  
Electromagnetic Compatibility  
Enclosure Protection  
Insulation  
CE marked: Fully tested to EN 50082-2 and EN 50082-1  
IP65  
Greater than 100 Mat 50 Vdc  
1 minute at 500 Vdc  
Insulation Test  
User Notes: Basic 100 mV transducers are calibrated at 10 Vdc to produce 0…100 mV signal (nominal), and require a stable voltage supply.  
They can be operated at 5 Vdc to give 0…50 mV signal or 20 Vdc to give 0…200 mV signal. The circuit is a compensated resis-  
tance bridge and is completely passive with no diodes or reactive components. Bridge resistance is 3,5Knominal.  
The 8…28 V supply transducer is fitted with an internal regulator. The mPm micro connector has a PG7 cable gland entry suitable  
for cables between 4 and 6 mm diameter. Screw terminals and solder lags are provided. The G 1/4 pressure connection has an  
integral Viton seal at the shoulder. Alternatively it may be sealed using a face seal on the flat nose of the pressure port.  
Subject to alterations  
4/99  
KELLER AG für Druckmesstechnik  
KELLER Gesellschaft für druckmesstechnik mbH  
St. Gallerstrasse 119  
Schwarzwaldstrasse 17  
CH-8404 Winterthur  
D-79798 Jestetten  
Tel. 052 - 235 25 25  
Tel. 07745 - 9214 - 0  
Fax 052 - 235 25 00  
Fax 07745 - 9214 - 50  
Companies approved to ISO 9001 / EN 29001  
Internet: http://www.keller-druck.ch  

相关型号:

PR-3

Multi-Voltage Conventional Relays
SYSTEMSENSOR

PR-30

Photo-reflector
CITIZEN

PR-30_12

Photo-reflector
CITIZEN

PR-40

Photo-reflector
CITIZEN

PR-40_12

Photo-reflector
CITIZEN

PR-JJFREQ1

Parallel - Fundamental Quartz Crystal, 12MHz Min, 40MHz Max
MTRONPTI

PR-JJFREQ2

Parallel - 3Rd Overtone Quartz Crystal, 40MHz Min, 100MHz Max
MTRONPTI

PR-JPFREQ1

Parallel - Fundamental Quartz Crystal, 12MHz Min, 40MHz Max
MTRONPTI

PR-JPFREQ2

Parallel - 3Rd Overtone Quartz Crystal, 40MHz Min, 100MHz Max
MTRONPTI

PR-MJFREQ2

Parallel - 3Rd Overtone Quartz Crystal, 40MHz Min, 100MHz Max
MTRONPTI

PR-MMFREQ2

Parallel - 3Rd Overtone Quartz Crystal, 40MHz Min, 100MHz Max
MTRONPTI

PR-MPFREQ1

Parallel - Fundamental Quartz Crystal, 12MHz Min, 40MHz Max
MTRONPTI