PVS-R-25 [ETC]
FUSE RK-5 25 A 600 AC/DC;PVS-R Series
Fast-Acting, UL Listed 600Vac/dc Solar Fuses
Carton Quantity and Weight
Amp
Carton
Qty.
10
10
1
Weight Per Carton
Ratings
20–30
35-60
Lbs.
Kg.
1.45
3.35
0.40
1.08
2.25
0.658
1.520
0.181
0.490
1.021
70–100
125–200
225-350
1
1
Dimensions - in (mm)
Amp Range
20-30
A
B
5.0 (127.0)
5.5 (139.7)
7.88 (200.0)
9.63 (244.5)
11.63 (295.3)
0.81 (20.6)
1.06 (27.0)
1.34 (34.0)
1.84 (46.7)
2.38 (60.5)
35-60
70-100
125-200
225-350
A
Catalog Symbol: PVS-R
Description
B
20-60A
A
A range of UL 2579 fast-acting 600Vdc Class RK5 fuses specifically
designed to protect solar power systems in extreme ambient temperature,
high cycling and low level fault current conditions (reverse current,
multi-array fault).
70-350A
B
Power Loss (Watts)
Catalog
Number
Amp
Rating
Power Loss (Watts)
0.8 x I 1.0 x I
Specifications
n
n
Volts: 600Vac to UL 248-12
600Vdc to UL 2579
PVS-R-30
PVS-R-60
PVS-R-100
PVS-R-200
PVS-R-350
30A
60A
100A
200A
350A
2.3
5.0
4.0
8.8
Amps: 20 - 350A
7.6
19.7
24.6
13.6
28.5
43.5
Interrupting Rating: 200kA RMS Sym. AC
20kA DC (20-60A)
10kA DC (70-350A)
I = Rated current.
n
General Information
Agency Information
• Designed specifically for the protection and isolation of photovoltaic
systems.
UL Std. 248-12, Class RK5, UL Listed, Guide JFGA, File E335324,
Photovoltaic to UL 2579, CSA Component Certified C22.2
Typical Applications
Catalog Numbers (Amps)
• Photovoltaic Systems
• Recombiner Boxes
• Solar DC Safety Switches
PVS-R-20 PVS-R-40
PVS-R-25 PVS-R-50
PVS-R-30 PVS-R-60
PVS-R-35 PVS-R-70
PVS-R-80
PVS-R-90
PVS-R-150 PVS-R-250
PVS-R-175 PVS-R-300
Recommended Fuse Blocks and Gear
Fits into standard Class RK5 holders, blocks and disconnects.
PVS-R-100 PVS-R-200 PVS-R-350
PVS-R-125 PVS-R-225
R600 Series
Data Sheet 1111
Data Sheet 1162
DC Safety Switch
1210 BU-SB101425
Page 1 of 2
Data Sheet 4203
Time-Current Characteristic Curves—Average Melt
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of
this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical informa-
tion that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of
any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice,
any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
© 2010 Cooper Bussmann
www.cooperbussmann.com
1210 BU-SB101425
Page 2 of 2
Data Sheet 4203
相关型号:
©2020 ICPDF网 联系我们和版权申明