RD-0515D/HP [ETC]
CONV DC/DC 2W 5VIN +/-15VOUT;型号: | RD-0515D/HP |
厂家: | ETC |
描述: | CONV DC/DC 2W 5VIN +/-15VOUT 输出元件 |
文件: | 总5页 (文件大小:1087K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 2W dual output converter
Features
• Industry standard SIP7 packages
• Power sharing on outputs
• Optional continuous short circuit protection
• 1kVDC and 2kVDC basic isolation
• UL94 V-0 package material
• Efficiency up to 87%
DC/DC Converter
Unregulated
Converters
RD
Description
2 Watt
SIP7
Dual Output
The RD series have been specifically designed for applications where dual power rails need to
be created from a single rail supply and a low cost solution is required. With efficiencies up to 87%,
the full output power is available over the operating temperature range -40°C to +85°C and
the converters can be used in ambient temperatures of up to 100°C with derating. The wide selection
of industry standard input voltage and output voltage options plus an input to output isolation of 1kVDC
or 2kVDC makes these converters suitable for many industrial applications.
Selection Guide
Part
Number
nom. Input
Voltage
Output
Voltage
Output
Current
Efficiency
typ. (1)
max. Capacitive
Load (2)
[VDC]
[VDC]
5
[mA]
200
84
[%]
[µF]
470
330
330
100
RD-xx05D(3,4)
RD-xx12D(3,4)
RD-xx15D(3,4)
RD-xx24D(3,4)
5, 12, 24
5, 12, 24
5, 12, 24
5, 12, 24
75-86
81-85
82-86
82-86
12
15
66
24
42
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
EN60950-1 certified
IEC60950-1 certified
Model Numbering
RD- __ __D/_
Protection (3)
Isolation ꢀption (4)
Dual
Input Voltage
ꢀutput Voltage
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: add suffix „/H“ for 2kVDC Isolation
or add suffix „/HP“ for Continuous Short Circuit Protection and 2kVDC Isolation
Ordering Examples:
RD-123.3D/P: 12V Input Voltage, 3.3V ꢀutput Voltage, Dual ꢀutput with continuous short circuit protection
RD-0509D/HP: 5V Input Voltage, 9V ꢀutput Voltage, Dual ꢀutput with 2kVDC Isolation and continuous short circuit protection
www.recom-power.com
REV.: 1/2018
ECO-1
RD
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Input Voltage Range
Minimum Load (5)
10ꢁ
0ꢁ
Internal ꢀperating Frequency
ꢀutput Ripple and Noise
20kHz
50kHz
85kHz
20MHz BW
150mVp-p
Notes:
Note5: ꢀperation below 10ꢁ load will not harm the converter, but specifications may not be met
Efficiency vs. Load
RD-xx05D
RD-xx12D
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0512
1212
2412
0505
1205
2405
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RD-xx15D
100
90
80
70
60
50
40
30
20
10
0
0515
1215
2415
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
www.recom-power.com
REV.: 1/2018
ECO-2
RD
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
Series
REGULATIONS
Parameter
ꢀutput Accuracy
Line Regulation
Condition
Value
5.0ꢁ max.
low line to high line, full load
1.2ꢁ of 1.0ꢁ Vin typ.
5Vout
12, 15 and 24Vout
15.0ꢁ max.
10.0ꢁ max.
Load Regulation
10ꢁ to 100ꢁ load
Deviation vs. Load
RD-xx05D
RD-xx12D
25
20
15
10
5
25
20
15
10
5
0505
1205
2405
0512
1212
2412
0
0
-5
-5
-10
-10
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RD-xx15D
25
20
15
10
5
0515
1215
2415
0
-5
-10
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
PROTECTIONS
Parameter
Type
Value
without suffix
with suffix “/P”
1 second
continuous
Short Circuit Protection (SCP)
tested for 1 second
1kVDC
500VAC/60Hz
without suffix
rated for 1 minute
I/P to ꢀ/P
Isolation Voltage (6)
with suffix
“/H”
tested for 1 second
rated for 1 minute
2kVDC
1kVAC/60Hz
10GΩ min.
Isolation Resistance
Isolation Capacitance
Insulation Grade
Notes:
40pF min. /115pF max.
basic
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T2A slow blow type
www.recom-power.com
REV.: 1/2018
ECO-3
RD
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
Series
ENVIRONMENTAL
Parameter
Condition
full load @ free air convection (see graph)
Value
-40°C to +85°C
2000m
ꢀperating Temperature Range
ꢀperating Altitude
ꢀperating Humidity
Pollution Degree
non-condensing
95ꢁ RH max.
PD2
+25°C
+85°C
18300 x 103 hours
8070 x 103 hours
MTBF
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ free air convection)
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
1602031
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety
EAC
RU-AT.49.09571
TP TC 004/2011
RoHs 2+
RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
potting
PCB
Value
non-conductive black plastic (UL94 V-1)
epoxy, (UL94 V-0)
Material
FR4, (UL94 V-0)
Dimension (LxWxH)
Weight
19.65x 7.05 x 10.2mm
2.8g typ.
continued on next page
REV.: 1/2018
www.recom-power.com
ECO-4
RD
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
Series
Dimension Drawing (mm)
embossed logo
Pinning information
19.65
7.0
Pin #
Dual
1
2
4
5
6
+Vin
-Vin
-Vout
Com
Marking
+Vout
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
0.05
0.51+0.10/-0.05
0.25
Recommended Footprint Details
Ø1.00 +0.15/-0
Bottom View
1 2
4 5 6
Top View
1 2
4 5 6
2.0
5 x 2.54= 12.7
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
Packaging Quantity
tube
tube
520.0 x 16.0 x 9.0mm
25pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95ꢁ RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 1/2018
ECO-5
相关型号:
©2020 ICPDF网 联系我们和版权申明