REC6-0509SRW/R10/A [ETC]
DC DC CONVERTER 9V 6W;型号: | REC6-0509SRW/R10/A |
厂家: | ETC |
描述: | DC DC CONVERTER 9V 6W 光电二极管 |
文件: | 总4页 (文件大小:108K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
● 8kVDC & 10kVDC Reinforced Isolation
● Industry Standard DIP24 Package
● 6W Regulated Output
● Continuous Short Circuit Protection
● Wide Input 2:1
ECONOLINE
DC/DC-Converter
with 3 year Warranty
Features
Regulated
Converters
● Medical Approved
● EN, CSA and CB Certificates
● 2 Pinout Options
● Control Pin Option
● Efficiency to 86%
6 Watt DIP24
Reinforced
Single & Dual
Output
The REC6 series uses a reinforced isolation transformer to offer exceptionally high isolation of
8kVDC (4kVAC/1 minute) or 10kVDC (5kVAC/1minute) making it suitable for HT monitoring cir-
cuits, mains power meters, IGBT isolated power supplies and other sophisticated industrial and
medical applications. The isolation capacitance of only 20pF makes them also suitable for low
leakage applications.The isolation transformer is recognized by CSA as reinforced isolated with
a minimum internal clearance of 2.4mm and a minimum internal creepage clearance of 4.6mm.
The REC6 is available in two industry-standard pinouts (= "/A" or "/C"). Remote on/off con-
trol is possible with the /CTRL option (A pinning only) and an optional undervoltage lockout
function is also available (="/X1"). The converters can deliver 140% rated power for short pe-
riods of time to cope with applications with large capacitive loads or high start up currents.
Description
Selection Guide
Part
Number
DIP24
Input
Voltage
(VDC)
Output Output Efficiency
Voltage Current
Max
Capacitive
Load(1)
(VDC)
(mA)
(%)
REC6-xx05SRW/R*
REC6-xx09SRW/R*
REC6-xx12SRW/R*
REC6-xx15SRW/R*
REC6-xx24SRW/R*
REC6-xx05DRW/R*
REC6-xx09DRW/R*
REC6-xx12DRW/R*
REC6-xx15DRW/R*
9 - 18, 18 - 36, 36 - 75
4.5 - 9
5
1000 80, 81, 82 6800µF
77
RoHS
6/6
2011/65/EU
E-314885
9 - 18, 18 - 36, 36 - 75
4.5 - 9
9
667
555
500
417
400
333
250
208
81, 82, 83 6800µF
80
C22.2-No. 60950 Certified
C22.2-601.1 Certified
UL-60601.1 Certified
9 - 18, 18 - 36, 36 - 75
4.5 - 9
12
15
24
5
82, 83, 84 6800µF
82
9 - 18, 18 - 36, 36 - 75
4.5 - 9
84, 85, 86 6800µF
83
REC6/R
9 - 18, 18 - 36, 36 - 75
4.5 - 9
83, 84, 85 4700µF
82
9 - 18, 18 - 36, 36 - 75
4.5 - 9
500 80, 81, 82 2200µF
77
Derating-Graph
(Ambient Temperature)
9 - 18, 18 - 36, 36 - 75
4.5 - 9
9
335 81, 82, 83 2200µF
278
250 81, 82, 83 2200µF
208 82
200 82, 83, 84 2200µF
167 80
80
9 - 18, 18 - 36, 36 - 75
4.5 - 9
12
15
9 - 18, 18 - 36, 36 - 75
4.5 - 9
120
100
R* = R8 or R10 for 8kVDC or 10kVDC isolation.
80
Note 1: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second
Safe Operating Area
60
without damage to the converter.
40
20
0
2:1 Input
(REC6-S_DRW/R8(R10)
* add suffix "/A" or "/C" for pinning options, see next page for details.
* add suffix “/CTRL” for control pin option (A Pinning only)
xx = 4.5-9Vin = 05
* add suffix "/X1" for Undervoltage Lockout
-40
0
25 50
125
105
75
xx = 9-18Vin = 12
85
Operating Temperature (°C)
xx = 18-36Vin = 24
xx = 36-75Vin = 48
Ordering Examples:
REC6-0512DRW/R8/A/CTRL= 5V Vin, 12V Vout, 8kVDC isolation, pinout “A”,control pin
REC6-4805SRW/R10/A = 48V Vin, 5V Vout, 10kVDC isolation, pinout “A”
REC6-1212DRW/R8/C/X1 = 12V Vin, 12V Vout, 8kVDC isolation, pinout “C”,UVL
REC6-0505SRW/R10/A/CTRL/X1 = 5V Vin, 5V Vout, 10kVDC isolation, pinout “A”,control pin, UVL
Refer to Application Notes
E-153
www.recom-power.com
REV: 0/2015
REC6-S_DRW
/R* Series
ECONOLINE
DC/DC-Converter
Specifications (measured at T = 25°C, nominal input voltage, full load and after warm-up)
A
Input Voltage Range
2:1
2% max.
Output Voltage Accuracy
Line Regulation
Load Regulation
Input Surge
(HL-LL)
0.3% max.
(for output load current change from 20% to 100%)
0.6% max.
(1 minute)
5V types
16V max.
12V types
24V types
48V types
5V types
25V max.
50V max.
100V max.
Undervoltage Lockout
(/X1 Versions)
3.5V typ. ( 20%)
7V typ. ( 20%)
15V typ. ( 10%)
32V typ. ( 10%)
200mVp-p max.
1ms typ.
12V types
24V types
48V types
Output Ripple and Noise
Transient Response
Switching Frequency
Input Filter
(0,1µF capacitor on output, 20MHz BW limited)
(25% step change)
(Full load and nominal input voltage)
100kHz min. / 350kHz max.
Pi Network
Capacitors
All types
MLCC capacitors only
Minimum Load
(Operation under no-load will not damage the converter, but it may not meet all specifications)
20% Full Load
400mW max.
8000VDC
No Load Power Consumption
Isolation Voltage
R8-Suffix
(tested for 1 second)
(rated for 1 minute**)
(tested for 1 second)
(rated for 1 minute**)
4000VAC / 60Hz
10000VDC
Isolation Voltage
R10-Suffix
5000VAC / 60Hz
20pF typ.
Isolation Capacitance
Isolation Resistance
Short Circuit Protection
Operating Temperature Range
Case Temperature
Storage Temperature Range
Relative Humidity
10 GΩ min.
(Max operating temp. = 50°C during short circuit conditions)
(free air convection)
Continuous, Auto Restart
-40°C to +75°C (see Graph)
105°C max.
-55°C to +125°C
95% RH
Case Material
Non-Conductive Plastic
Silicone
Potting Material
Thermal Impedance
Package Weight
Natural convection
20°C/W
14g
Packing Quantity
15 pcs per Tube
953 x103 hours
234 x103 hours
Class A
MTBF (+25°C)
using MIL-HDBK 217F
Detailed Information see
Application Notes chapter "MTBF"
}
(+75°C)
using MIL-HDBK 217F
EN55022
EMC
Conducted Emissions
(with 470µF//0.1µF capacitors across input) Radiated Emissions
EN55022
Class A
Reinforced Isolation
Transformer Creepage
Transformer Clearance
PCB Creepage & Clearance
Optocoupler Creepage
Plastic Case
/R8 and /R10 Types
4.6 mm min.
/R8 and /R10 Types
2.4 mm min.
/R8 and /R10 Types
6.0 mm min.
/R8 and /R10 Types
6.0 mm min.
External Creepage and Clearance
Input <> Output pins
Report: MDD1207051 + RM1207051
Medical Report + ISO14971 Risk Assessment
CB-Report: CA-10168-A1-UL
Report: 2202478
14.2 mm min.
EN 60601-1 3rd Edition
Certifications
EN Medical Safety
IEC Medical Safety
IEC60601-1 3rd Edition
C22.2 601-1 2nd Ed.
CSA
UL
Medical Safety
Medical Safety
General Safety
E314885-A4
UL 60601-1 3rd Edition
Report: 2219431
C22.2 No. 60950-1-03
UL 60950-1 1st Ed.
Recognised as Reinforced Isolation
Supplement to Report: 2219431
**Any data referred to in this datasheet are of indicative nature and based on our practical experience only. For further details, please refer to our Application Notes.
E-154
REV: 0/2015
www.recom-power.com
REC6-S_DRW
/R* Series
ECONOLINE
DC/DC-Converter
Typical Characteristics
Efficiency vs Vin
Efficiency vs Load
Efficiency VS Input Voltage
Efficiency / Load
100
80
1205
4805
90
88
4805
2405
86
84
82
80
78
76
74
72
0505
60
REC6-xx05SRW/R*
REC6-xx05DRW/R*
2405
40
1205
0505
20
0
70
min
max+20%
nom
max
0%
40%
80%
100%
20%
60%
Total Output current (%)
Input Voltage (V)
Efficiency VS Input Voltage
Efficiency / Load
0512
100
80
4812
2412
90
88
86
84
82
80
78
76
74
72
1212
4812
1212,
2412
60
REC6-xx12SRW/R*
0512
40
20
0
70
min
max+20%
nom
max
0%
40%
80%
100%
20%
60%
Total Output current (%)
Input Voltage (V)
Efficiency VS Input Voltage
Efficiency / Load
4824
100
80
1224
4824
90
88
86
84
82
80
78
76
74
72
2424
0524
0524
1224,
2424
60
REC6-xx24SRW/R*
REC6-xx12DRW/R*
40
20
0
70
min
max+20%
nom
max
0%
40%
80%
100%
20%
60%
Total Output current (%)
Input Voltage (V)
www.recom-power.com
REV: 0/2015
E-155
REC6-S_DRW
/R* Series
ECONOLINE
DC/DC-Converter
Package Style and Pinning (mm) DIP 24 (continued)
“A” Pinning
32.00
20.30
/R8 & /R10
Pin Connections
10.20
Pin #
Single
Dual
CTRL
–Vin
1 (option) CTRL
4.1+0.25 /-0.5
2
11
14
16
22
23
–Vin
NC
15.24
0.51
4.60
–Vout
+Vout
Com
+Vout
–Vout
+Vin
+Vin
Recommended Footprint Details
ø
1.00 +0.15/0
+Vin
+Vin
NC = No Connection
(1) 2
11
Bottom View
16 14
2.54
23 22
XX.X
0.5 mm
XX.XX 0.25 mm
Top View
CRTL Version only
2.54
22,23
2
Vin+
0V
CTRL Option
REC6-xxxx/CTRL
ON = Open or 0V< V <1.2V
ctrl
CTRL
1
OFF = 2.2V< V <12V
ctrl
1kW
1N4148
Off
On
TTL Input
“C” Pinning
/R8 & /R10
20.30
Pin Connections
32.00
Pin #
1
Single
+Vin
+Vin
NC
Dual
+Vin
+Vin
Com
Com
NC
10.20
2
4.1+0.25 /-0.5
10
11
12
13
15
23
24
15.24
0.51
2.03
NC
–Vout
+Vout
NC
Recommended Footprint Details
–Vout
+Vout
–Vin
–Vin
ø
1.00 +0.15/0
–Vin
–Vin
1
2
11
10 12
NC = No Connection
Bottom View
2.54
24 23
15 13
XX.X
0.5 mm
XX.XX 0.25 mm
Top View
2.54
The product information and specifications are subject to change without prior notice. RECOM products are not authorized for use in safety-critical applications (such as life support) without RECOM’s explicit
written consent. A safety-critical application is defined as an application where a failure of a RECOM product may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The buyer
shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications.
E-156
REV: 0/2015
www.recom-power.com
相关型号:
©2020 ICPDF网 联系我们和版权申明