RH-1205D/H [ETC]
CONV DC/DC 1W 12VIN +/-05VOUT;型号: | RH-1205D/H |
厂家: | ETC |
描述: | CONV DC/DC 1W 12VIN +/-05VOUT 输出元件 |
文件: | 总8页 (文件大小:1181K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 3kVDC/1s or 4kVDC/1s isolation
• Optional continuous short circuit protection
• UL94V-0 package material
Features
DC/DC Converter
Unregulated
Converters
• Efficiency up to 84%
• Suitable for IGBT applications
RK & RH
Description
1 Watt
SIP7
Single and Dual
Output
The RK and RH Series DC/DC-Converter complements RECOM’s industrial range of converters with
very high isolations of 3kVDC/1s and 4kVDC/1s. The extended operating temperature range covering
–40°C to +90°C is a standard feature.The converters are IEC/EN/UL60950-1 certified, and are suitable
for IGBT driver applications.
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
Max. Capacitive
Load(2)
[%]
[µF]
RK-xx05S (3,4)
RK-xx09S (3,4)
RK-xx12S (3,4)
RK-xx15S (3,4)
RH-xx05D (3,4)
RH-xx09D (3,4)
RH-xx12D (3,4)
RH-xx15D (3,4)
RH-xx1509D (3,4)
5, 12, 15, 24
5, 12, 15, 24
5,12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 15, 24
5, 12, 24
5
9
200
111
84
70-78
70-80
78-82
80-82
74-78
76-79
78-84
80-84
70-81
1000
1000
470
12
15
5
66
470
100
56
470
9
470
12
15
+15/-9
42
220
33
220
+33/-56
+220/-470µF
Notes:
E358085
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
UL60950-1 certified
Model Numbering
CSA/CAN C22.2 No. 60950-1-07 certified
IEC/EN60950-1 certified
IEC/EN60601-1 certified*
EN55032 compliant
RK- __ __ S/
Protection (3)
Isolation ꢀption (4)
Single
Input Voltage
*+15/-9 version excluded
ꢀutput Voltage
RH- __ __ D/_
Protection (3)
Isolation ꢀption (4)
Dual
Input Voltage
ꢀutput Voltage
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: add suffix „/H“ for 4kVDC/1s Isolation
or add suffix „/HP“ for Continuous Short Circuit Protection and 4kVDC/1s Isolation
Ordering Examples:
RH-123.3D/P: 12V Input Voltage, 3.3V ꢀutput Voltage, Dual ꢀutput with continuous short circuit protection
RK-0509S/HP: 5V Input Voltage, 9V ꢀutput Voltage, Single ꢀutput with 4kVDC/1s Isolation and continuous short circuit protection
www.recom-power.com
REV.: 5/2019
ECO-1
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Fuse
Input Voltage Range
Minimum Load
capacitors
10ꢁ
0ꢁ
Start-up Time
250ms
105kHz
Internal ꢀperating Frequency
ꢀutput Ripple and Noise
50kHz
100kHz
20MHz BW
100mVp-p
Efficiency vs. Load
RK-xx05S
RK-xx09S
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
3.305
0505
1205
3.309
0509
1209
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RK-xx12S
RK-xx15S
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
3.312
0512
1212
3.315
0515
1215
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
www.recom-power.com
REV.: 5/2019
ECO-2
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Efficiency vs. Load
RH-xx05D
RH-xx09D
100
90
80
70
60
50
40
30
100
90
80
70
60
50
40
30
20
10
0
20
10
0
3.305
0505
1205
3.309
0509
1209
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RH-xx12D
RH-xx15D
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
3.312
0512
1212
3.315
0515
1215
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
REGULATIONS
Parameter
ꢀutput Accuracy
Condition
Values
5.0ꢁ max.
Line Regulation
low line to high line
5Vout
9, 12, 15Vout and RH-xx1509D
1.2ꢁ of 1.0ꢁ Vin typ.
15.0ꢁ max.
Load Regulation(5)
10ꢁ to 100ꢁ load
10.0ꢁ max.
Notes:
Note5: ꢀperation below 10ꢁ load will not harm the converter, but specifications may not be met
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-3
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Deviation vs. Load
RK-xx05S
RK-xx09S
25
25
20
15
10
5
3.305
0505
1205
3.309
0509
1209
20
15
10
5
0
0
-5
-10
-5
-10
0
0
0
10 20 30 40 50 60 70 80 90 100
0
0
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RK-xx12S
RK-xx15S
25
20
15
10
5
25
20
15
10
5
3.312
0512
1212
3.315
0515
1215
0
0
-5
-5
-10
-10
10 20 30 40 50 60 70 80 90 100
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RH-xx05D
RH-xx09D
25
20
15
10
5
25
20
15
10
5
3.305
0505
1205
3.309
0509
1209
0
0
-5
-5
-10
-10
10 20 30 40 50 60 70 80 90 100
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-4
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Deviation vs. Load
RH-xx12D
RH-xx15D
25
25
20
15
10
5
3.312
0512
1212
3.315
0515
1215
20
15
10
5
0
0
-5
-10
-5
-10
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
PROTECTIONS
Parameter
Condition
Value
without suffix
with suffix “/P”
1 second
continuous
Short Circuit Protection (SCP)
tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC
without suffix
Isolation Voltage (6)
I/P to ꢀ/P
tested for 1 second
rated for 1 minute
4kVDC
2kVAC
with suffix “/H”
RK types
RH types
20pF min. / 75pF max.
20pF min. / 65pF max.
Isolation Capacitance
Isolation Resistance
Insulation Grade
Notes:
15GΩ min.
basic (IEC/EN60950-1)
functional (IEC/EN60601-1)
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
ꢀperating Temperature Range
ꢀperating Altitude
Condition
full load @ free air convection (see graph)
Value
-40°C to +90°C
3000m
ꢀperating Humidity
Pollution Degree
non-condensing
5ꢁ - 95ꢁ RH max.ꢁ
PD2
+25°C
+85°C
992 x 10³ hours
145 x 10³ hours
RK type
MTBF
according to MIL-HDBK-217F; G.B.
+25°C
+85°C
1012 x 10³ hours
151 x 10³ hours
RH type
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-5
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Derating Graph
(@ free air convection)
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110
95
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
UL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
Information Technology Equipment, General Requirements for Safety
E358085-A4-UL
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety
SPCLVD1602031
Medical electrical equipment Part 1: General requirements for basic
safety and essential performance
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 + A1:2013 + A12:2014
WD-SE-R-180676-A0 (8)
RU-AT.49.09571
EAC
TP TC 004/2011
RoHS 2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(see filter suggestion below)
EN55032, Class B
EN55032, Class A
Notes:
Note8: excluded +15/-9 version
EMC Filter Suggestion according to EN55032
Single Output
C3
L1
+Vin
+Vout
+Vin
+Vout
C1
C2
-Vin
-Vout
-Vin
-Vout
Component List Class A
Component List Class B
MODEL
C1
L1
C2
C3
MODEL
C1
L1
C2
C3
N/A
RK-0505S
RK-0515S
RK-2405S
N/A
RK-0505S
RK-0515S
RK-2405S
10µF
100V MLCC
10µF
12µH choke
4.7µF
50V MLCC
22µH choke RLS-226
12µH choke RLS-126
N/A
N/A
2.2nF
N/A
100V MLCC RLS-126
Notes:
Note9: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECꢀM tech support for advice
www.recom-power.com
REV.: 5/2019
ECO-6
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
case
potting
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
Material
standard
with suffix “/H”
19.65 x 6.0 x 10.2mm
19.65 x 7.05 x 10.2mm
Dimension (LxWxH)
Weight
standard
with suffix “/H”
2.6g typ.
2.8g typ.
Dimension Drawing (mm)
Standard Version
embossed logo
19.65
6.0
Pinning Information
Pin #
Single
+Vin
-Vin
-Vout
no pin
+Vout
Dual
+Vin
-Vin
-Vout
Com
+Vout
1
2
5
6
7
Marking
0.05
0.5+0.10/-0.05
0.25
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
Recommended Footprint
Bottom View
1 2
5 6 7
1 2
5 6 7
Top View
2.00
6x2.54= 15.24
2.54
„H“ - Version
embossed Logo
19.65
7.05
Pinning Information
Pin #
Single
+Vin
-Vin
-Vout
no pin
+Vout
Dual
+Vin
-Vin
-Vout
Com
+Vout
Marking
1
2
5
6
7
0.05
0.5+0.10/-0.05
0.25
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
Recommended Footprint
Bottom View
1 2
5 6 7
1 2
5 6 7
Top View
4 x 2.54 = 10.16
6 x 2.54 =15.24
2.54
2.00
www.recom-power.com
REV.: 5/2019
ECO-7
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
INSTALLATION AND APPLICATION
IGBT Application Circuit
+
Q1
C
Signal+
IC1
R1
G
OUT
IN
IGBT Driver
-Vin
Signal-
+Vin
E
+Vout
IC2
DC
+Vin
-Vin
DC
C2
C3
C1
-Vout
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
tube
tube
Value
520.0 x 16.0 x 9.0mm
25pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95ꢁ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 5/2019
ECO-8
相关型号:
©2020 ICPDF网 联系我们和版权申明