Data Sheet  
True RMS Bench Multimeter  
5492B  
True RMS Bench Multimeter  
Features & benefits  
The B&K Precision model 5492B is a versatile  
5½-digit, 120,000-count bench multimeter  
suitable for applications in education, service  
repair, and manufacturing. The instrument  
enhances your productivity with built-in math  
functions and USB connectivity. Rel, Max/Min,  
dBm, dB, %, and Hold functions provide  
educators with a convenient tool to teach basic  
math concepts. Additionally, the 5492B offers  
powerful features not commonly found in other  
5½- digit DMMs such as advanced triggering,  
buffer storage operation, and a GPIB interface  
option.  
The 5492B measures volts and amps with great  
I 5½-digit, 120,000-count display resolution  
I 0.01% basic VDC accuracy  
accuracy and stability, with basic VDC accuracy  
of 0.01%. The meter is also capable of measur-  
ing frequency, period, resistance, continuity, and  
performing diode tests. Readings can be taken at  
a maximum rate of 57 readings/sec and stored  
to an internal 512-byte buffer for post  
I Advanced triggering options such as external,  
bus and event trigger  
I Two and four-wire resistance measurement up  
to 120 MΩ  
acquisition statistical analysis.  
I AC voltage and AC current measurement over  
wide frequency range (ACV 100 kHz/ACI 10  
kHz)  
The 5492B was designed for cost-conscious  
users requiring an accurate meter with a broad  
range of features offered at a value price.  
I AC (RMS) and DC current measurements up  
to 12 A  
I Limit mode for Pass/Fail testing  
I Save/recall up to 10 instrument settings  
I Built-in math functions: Rel, Max/Min, dBm,  
dB, %, Hold, Limit Test  
Increase Productivity with PC Connectivity  
The 5492B is programmable via USB, RS232,  
and GPIB (5492BGPIB only) interface using  
industry standard SCPI commands. Users can  
remotely control and configure the instrument  
from a PC and retrieve measurement results for  
further analysis. The multimeter can also be  
remotely controlled using application software  
(via USB & RS232), which supports front panel  
emulation and data logging of measurement  
results.  
I CATI (1000 V)/CATII (300 V) protection  
I USB (Virtual Com) and RS232 interface  
I SCPI compatible  
Technical data subject to change  
© B&K Precision Corp. 2017  
www.bkprecision.com  
True RMS Bench Multimeter  
Model 5492B  
Easy operation  
Versatile tools  
L
L
Limit Operation  
Front panel  
The limit operation lets you set and control the  
values that determine a HI / IN / LO status of  
subsequent measurements. The meter can be  
configured to emit an audible alarm when  
readings are outside of the configured limit.  
Bright VFD display  
Input banana terminals  
Advanced Triggering  
A variety of advanced trigger options are  
available: Manual Trigger via a front panel button  
press, Bus Trigger sending a *TRG command  
via PC interface, External Trigger using the EXT  
TRIG input terminal on the rear panel.  
Additionally, a trigger delay can be programmed  
after an event detection, and a VM Comp output  
is available to indicate the instrument’s  
Power button  
Interface keypad  
mA Fuse socket  
completion of a present measurement.  
Fast Buffering with Built-in  
Statistics  
VM Comp  
(Voltmeter  
Rear panel  
External  
RS-232  
(Serial) interface  
Trigger BNC  
input terminal  
complete) BNC  
output terminal  
The 5492B provides an internal buffer capable  
of storing up to 512 readings. Buffer storage  
operation can be enabled via front panel or  
remote command. The buffer fills up with the  
requested number of readings at a rate of up to  
57 readings/sec and then stops. The instrument  
automatically calculates statistical information  
based on the stored readings such as minimum,  
maximum, or average reading, and standard  
deviation, which can then be retrieved along with  
the readings via the front panel or remote  
command.  
Serial number label  
USB interface  
Power line  
fuse holder  
GPIB (IEEE-488) interface Chassis ground  
(model 5492BGPIB) screw terminal  
2
www.bkprecision.com  
True RMS Bench Multimeter  
Model 5492B  
Specifications  
Specifications are based on the following conditions:  
I One year calibration cycle  
I Operating temperature between 18 °C to 28 °C  
I Accuracy expressed as: (% of reading + % of range) after 30 minutes warm-up and valid for 10 PLC (Slow)  
I Temperature coefficient: add [0.1% × (applicable accuracy)/°C] for 0 °C to 18 °C and 28 °C to 40 °C  
I Relative humidity: Up to 80% RH for 0 °C to 28 °C (75% RH for 10 MΩ and above ranges  
for resistance measurement), up to 70% RH for 28 °C to 40 °C  
DC Voltage  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
Full Scale  
Reading  
Accuracy  
(1 year)  
Typical Input  
Impedance  
Range  
Resolution  
(1)  
(1)  
120.000 mV  
1.20000 V  
12.0000 V  
120.000 V  
1000.00 V  
1 µV  
10 µV  
100 µV  
1 mV  
119.999  
1.19999  
11.9999  
119.999  
0.02+0.008  
0.01+0.004  
>10 GΩ  
>10 GΩ  
>10 GΩ  
10 MΩ 1%  
10 MΩ 1%  
0.01+0.004  
0.01+0.004  
0.01+0.004  
(2)  
10 mV  
1010.00  
(1) under REL status  
(2) 1% overrange (1010 V) is readable at 1000 V range  
Input protection: 1000 V  
AC Voltage (True RMS, AC coupled)  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
(1)  
Accuracy (1 year)  
Full Scale  
Reading  
Range  
Resolution  
10-20 Hz  
20-50 Hz  
50-20 kHz  
20-50 kHz  
50-100 kHz  
120.000 mV  
1.20000 V  
12.0000 V  
120.000 V  
750.00 V  
1 µV  
10 µV  
100 µV  
1 mV  
119,999  
1.19999  
11.9999  
119.999  
1.50+0.100  
1.50+0.100  
1.50+0.100  
1.50+0.100  
1.50+0.100  
0.50+0.100  
0.50+0.100  
0.50+0.100  
0.50+0.100  
0.50+0.100  
0.10+0.100  
0.10+0.100  
0.10+0.100  
0.10+0.100  
0.10+0.100  
0.30+0.150  
0.30+0.150  
0.30+0.150  
0.30+0.150  
1.0+0.150  
1.0+0.100  
1.0+0.100  
1.0+0.100  
(3)  
(2)  
(1)  
10 mV  
757.50  
0.30+0.150  
1.0+0.100  
(1) Specifications are for sine wave inputs >5% of range  
(2) 3×107 Volt-Hz for 750 V range  
(3) 1% overrange (757.5V) is readable at 750 V range  
Measurement method: AC coupled true RMS, measuring the AC component only  
Maximum Crest factor: 3.0 at full scale  
Input impedance: 1 MΩ 2% in parallel with capacitance <100 pF  
Input protection: 750 Vrms, 500 Vdc  
DC Current  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
(1)  
Full Scale  
Reading  
Accuracy  
(1 year)  
Burden Voltage  
& Shunt Resistor  
Range  
Resolution  
(2)  
(2)  
12.0000 mA  
120.000 mA  
1.20000 A  
0.1 µA  
1 µA  
10 µA  
100 µA  
11.9999  
119.999  
1.19999  
11.9999  
0.05+0.008  
0.05+0.004  
<0.15 V / 10.1 Ω  
<1.5 V / 10.1 Ω  
<0.3 V / 0.1 Ω  
0.10+0.004  
0.25+0.004  
(3)  
12.0000 A  
<0.15 V / 10 mΩ  
(1) Typical voltage across the input terminals at full scale reading  
(2) Use REL function  
(3) In 12 A range, >10~12 ADC is readable for 20 seconds maximum  
Input protection: Externally accessible 2A / 250V fuse protecting the low input current terminal (LO).  
Internally accessible 20A / 250V fuse protecting the high current input terminal (10A)  
3
www.bkprecision.com  
True RMS Bench Multimeter  
Model 5492B  
Specifications (cont.)  
AC Current (True RMS, AC Coupled)  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
(3)  
(1)  
Accuracy (1 year)  
Full Scale  
Reading  
Burden Voltage  
Range  
Resolution  
& Shunt Resistor  
10-20 Hz  
1.0+0.080  
1.0+0.080  
1.0+0.080  
20-50 Hz  
0.50+0.080  
0.50+0.080  
0.50+0.080  
50-2 kHz  
0.25+0.080  
0.25+0.080  
0.25+0.080  
2-20 kHz  
2.0+0.080  
2.0+0.080  
2.0+0.080  
12.0000 mA  
1.20000 A  
0.1 µA  
10 µA  
11.9999  
1.19999  
11.9999  
<0.15 V / 10.1 Ω  
<0.3 V / 0.1 Ω  
(2)  
12.0000 A  
100 µA  
<0.15 V / 10 mΩ  
(1) Typical voltage across the input terminals at full scale reading  
(2) In 12 A range,>10-12 A AC is readable for 20 seconds maximum  
(3) Specifications are for sine wave inputs >5% of range  
Measurement method: AC coupled true RMS, measuring the AC component only  
Input protection: Externally accessible 2 A / 250 V fuse protecting the low input current terminal (LO). Internally accessible 20 A / 250 V fuse protecting the  
high current input terminal (10A)  
Max. crest factor: 3.0 at full scale  
Resistance (2-Wire and 4-Wire)  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
Accuracy  
(1 year)  
(1)  
Range  
Resolution  
Full Scale Reading  
Test Current  
(2)  
(2)  
(2)  
120.000 Ω  
1.20000 kΩ  
12.0000 kΩ  
120.000 kΩ  
1.20000 MΩ  
12.0000 MΩ  
120.000 MΩ  
1 mΩ  
10 mΩ  
100 mΩ  
1 Ω  
10 Ω  
100 Ω  
1 kΩ  
119.999  
1.19999  
11.9999  
119.999  
1.19999  
11.9999  
119.999  
1 mA  
1 mA  
100 µA  
10 µA  
10 µA  
0.05 +0.008  
0.03 +0.004  
0.03 +0.004  
0.03 +0.004  
0.03 +0.004  
0.10 +0.004  
0.50 +0.008  
7.0/(10M+Rx) µA  
7.0/(10M+Rx) µA  
(1) In order to eliminate the noise interference, which might be induced to the test leads, it is recommended to use a  
shielded test cable for measuring resistance above 120 kΩ  
(2) Using REL function  
Input protection: 1000 Vdc or 750 Vac for all ranges  
Note: Rx is the measured resistance value  
Continuity  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
Full Scale  
Reading  
Accuracy  
(1 year)  
Range  
Resolution  
Test Current  
1 mA  
1 kΩ  
100 mΩ  
999.9  
0.1%+0.02%  
For 0.1 PLC (Fast)  
Input protection: 1000 Vdc or 750 Vac  
Diode  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
Full Scale  
Reading  
Accuracy  
(1 year)  
Range  
Resolution  
Test Current  
3.0000 V  
10.0000 V  
10.0000 V  
100 µV  
100 µV  
100 µV  
2.9999  
10.0000  
10.0000  
1 mA  
100 µA  
10 µA  
0.030+0.020  
0.030+0.020  
0.030+0.020  
For 1 PLC (Medium)  
Input protection: 1000 Vdc or 750 Vac for all ranges  
4
www.bkprecision.com  
True RMS Bench Multimeter  
Model 5492B  
Specifications (cont.)  
Frequency  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
ACV  
Range  
Full Scale  
Reading  
Input Sensitivity  
(Sine Wave)  
(2)  
Frequency Range  
Resolution  
Accuracy  
5 ~ 10 Hz  
10 ~ 100Hz  
100 ~ 100 kHz  
10 µHz  
100 µHz  
1 mHz  
1 Hz  
9.99999  
99.9999  
999.999  
999.999  
0.05  
0.01  
0.005  
0.005  
200 mVrms  
40 mVrms  
40 mVrms  
100 mVrms  
100 mV  
to  
750 V  
(1)  
100 k ~ 1 MHz  
(1) If testing frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed.  
(2) Specified accuracy at input >5 % of range.  
Gate Time at 1 Sec.  
Input protection: 750 Vrms or 500 Vdc  
Period  
Resolution, Full Scale Reading and Accuracy (% of reading + % of range), 23 °C 5 °C  
Full Scale  
Reading  
Input Sensitivity  
(2)  
ACV Range  
Period Range  
Resolution  
Accuracy  
(Sine Wave)  
100 mVrms  
40 mVrms  
40 mVrms  
200 mVrms  
(1)  
1 ~ 10 µs  
0.01 ns  
0.1 ns  
0.1 µs  
1 µs  
9.99999  
9.99999  
99.9999  
199.999  
0.005  
0.005  
0.01  
100 mV  
to  
750 V  
10 µs ~ 10 ms  
10 ms ~ 100 ms  
100 ms ~ 200 ms  
0.05  
(1) If testing frequency is greater than 1MHz, it will be displayed but no specified accuracy is guaranteed.  
(2) Specified accuracy at input >5 % of range.  
Gate Time at 1 Sec.  
Input protection: 750 Vrms or 500 Vdc  
Supplemental  
Environmental  
Operating Environment  
Storage Environment  
Humidity  
0 °C to 40 °C, 32 ºF to 104 ºF  
-40 °C to 70 °C -40 ºF to 158 ºF  
90 %RH  
General  
Remote Interfaces  
Measurement Category  
Math Functions  
RS232, USB (virtual COM) GPIB (model 5492BGPIB only)  
CAT II 300V, CAT I 1000V, pollution degree 2  
Rel, Max/Min/Average/StdDev (for stored readings), dB, dBm, Limit Test, % and mX+b  
110/220 V 10%, 50/60 Hz 5%  
AC Input  
Power Consumption  
20 VA  
EN 61010-1:2001, EN61326-1:2006 and  
EN61326-2-1:2006  
Safety & EMC  
8.85” x 3.93 “ x 13.97”  
(225 mm×100 mm×355 mm)  
Dimensions (W×H×D)  
Net Weight  
5.51 lbs (2.5 kg)  
Three-Year Warranty  
Test leads, AC power cord, spare fuse, user manual, USB cable, calibration certificate  
and test report  
Included Accessories  
5
www.bkprecision.com  
v052517  

相关型号:

RK08H

Without Knob Type
ALPS

RK08H1

RESISTOR, POTENTIOMETER, 1 TURN(S), 0.03W, 5000ohm - 100000ohm
ALPS

RK08H11100U3

Without Knob Type
ALPS

RK08H11100UD

Without Knob Type
ALPS

RK08H11100X7

Without Knob Type
ALPS

RK08H11100XC

Without Knob Type
ALPS

RK08H1110A04

Without Knob Type
ALPS

RK08H1120

RESISTOR, POTENTIOMETER, 1 TURN(S), 0.03W, 5000ohm - 100000ohm
ALPS

RK08H1120030

Without Knob Type
ALPS

RK08H1120A05

Compact type potentiometer suitable for volume and tone controls
ALPS

RK08H1130

暂无描述
ALPS

RK08H113003G

Without Knob Type
ALPS