RKZ-0512D/P [ETC]
CONV DC/DC 2W 05VIN +/-12VOUT;型号: | RKZ-0512D/P |
厂家: | ETC |
描述: | CONV DC/DC 2W 05VIN +/-12VOUT |
文件: | 总7页 (文件大小:880K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• High isolation 2W converter
Features
• 3kVDC/1s and 4kVDC/1s basic isolation
• UL94V-0 package material
DC/DC Converter
• Optional continuous short circuit protected
• Efficiency up to 84%
Unregulated
Converters
• Suitable for IGBT applications
RKZ
Description
2 Watt
SIP7
The RKZ Series of 2W DC/DC Converters are certified to EN60950-1. This makes them suitable for high
end industrial applications such as IGBT driver circuitry. The RKZ converters are pin-compatible with the
RK and RH converter series, offering a simple way to upgrade a 1W high isolation supply to 2W.
Single and
Dual Output
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load (2)
[µF]
RKZ-xx05S (3,4)
RKZ-xx12S (3,4)
RKZ-xx15S (3,4)
RKZ-xx05D (3,4)
RKZ-xx12D (3,4)
RKZ-xx15D (3,4)
RKZ-xx1509D (3,4)
5, 12, 24
5, 12, 24
5, 12, 24
5, 12, 24
5, 12, 24
5, 12, 24
5, 12, 24
5
12
400
168
82-84
82-87
82-84
70-83
82-84
82-88
70-81
1500
330
330
680
220
220
330
15
132
5
200
12
84
15
66
+15/-9
+67/-111
Notes:
IEC/EN60950-1 certified
IEC/EN60601-1 certified
EN55032 compliant
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
Model Numbering
RKZ- __
/
Protection (3)
nom. Input Voltage
Output Voltage
Isolation Option (4)
Single or Dual
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: add suffix „/H“ for 4kVDC/1s Isolation
or add suffix „/HP“ for 4kVDC/1s Isolation and Continuous Short Circuit Protection
Ordering Examples:
RKZ-0515S/P: 5VDC Input Voltage, 15VDC Output Voltage, Single Output with continuous short circuit protection
RKZ-0515D/HP: 5VDC Input Voltage, 15VDC Output Voltage, Dual Output with continuous short circuit protection and 4kVDC/1s isolation
www.recom-power.com/eval-ref-boards
www.recom-power.com
REV.: 5/2019
ECO-1
RKZ
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
Input Voltage Range
Minimum Load
capacitor
10ꢀ
0ꢀ
all others
RKZ-xx1509D
20kHz
20kHz
50kHz
51kHz
85kHz
Internal Operating Frequency
Output Ripple and Noise
20MHz BW
150mVp-p
Efficiency vs. Load
RKZ-xx05S
RKZ-xx12S
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0505
1205
2405
0512
1212
2412
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RKZ-xx15S
RKZ-xx05D
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0515
1215
2415
0505
1205
2405
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
continued on next page
REV.: 5/2019
www.recom-power.com
ECO-2
RKZ
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
Efficiency vs. Load
RKZ-xx12D
RKZ-xx15D
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
0512
1212
2412
0515
1215
2415
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
5.0ꢀ max.
low line to high line
5Vout
12, 15, 24Vout and RKZ-xx1509D
1.2ꢀ of 1.0ꢀ Vin typ.
15.0ꢀ max.
10.0ꢀ max.
Load Regulation(5)
10ꢀ to 100ꢀ load
Notes:
Note5: Operation below 10ꢀ load will not harm the converter, but specifications may not be met
Deviation vs. Load
RKZ-xx05S
RKZ-xx12S
25
20
15
10
5
25
20
15
10
5
0505
1205
2405
0512
1212
2412
0
0
-5
-5
-10
-10
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
continued on next page
REV.: 5/2019
www.recom-power.com
ECO-3
RKZ
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
Deviation vs. Load
RKZ-xx15S
RKZ-xx05D
25
20
15
10
5
25
20
15
10
5
0515
1215
2415
0505
1205
2405
0
0
-5
-5
-10
-10
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RKZ-xx12D
RKZ-xx15D
25
20
15
10
5
25
20
15
10
5
0512
1212
2412
0515
1215
2415
0
0
-5
-5
-10
-10
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
PROTECTIONS
Parameter
Type
Value
without suffix
with suffix “/P”
1 second
continuous
Short Circuit Protection (SCP)
tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC / 60Hz
without suffix
with suffix “/H”
Isolation Voltage (6)
I/P to O/P
tested for 1 second
rated for 1 minute
4kVDC
2kVAC / 60Hz
10GΩ min.
Isolation Resistance
Isolation Capacitance
120pF max.
basic (IEC/EN60950-1)
functional (IEC/EN60601-1)
Insulation Grade
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 5/2019
ECO-4
RKZ
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
ENVIRONMENTAL
Parameter
Condition
full load @ free air convection (see graph)
Value
-40°C to +85°C
+110°C
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
Operating Altitude
0.03ꢀ/K typ.
40K/W typ.
3000m
Operating Humidity
Pollution Degree
non-condensing
95ꢀ RH max.
PD2
+25°C
+85°C
18300 x 103 hours
8070 x 103 hours
MTBF
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ free air convection)
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety
SPCLVD1602031
Medical electrical equipment Part 1: General requirements for basic
safety and essential performance
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 + A1:2013 + A12:2014
WD-SE-R-180676-A0 (8)
RU-AT.49.09571
EAC
TP TC 004/2011
RoHS 2+
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(see filter suggestion below)
EN55032, Class B
EN55032, Class A
Notes:
Note8: excluded +15/-9 version
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-5
RKZ
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
EMC Filter Suggestion according to EN55032
C2
L1
+Vin
+Vout
+Vin
-Vin
+Vout
C1
-Vout
-Vin
-Vout
C3
Component List Class A
Component List Class B
MODEL
C1
L1
C2 (safety) C3 (safety)
MODEL
C1
L1
C2 (safety) C3 (safety)
12µH choke
RLS-126
RKZ-0505S
RKZ-1205S
RKZ-2405S
RKZ-0505S
10µF
100V MLCC
10µF
100V MLCC
N/A
N/A
N/A
470pF
1nF
RKZ-1205S
RKZ-2405S
22µH choke
RLS-226
Notes:
Note9: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
potting
PCB
Value
non-conductive black plastic (UL94 V-0)
epoxy, (UL94 V-0)
Material
FR4, (UL94 V-0)
Dimension (LxWxH)
Weight
19.65 x 7.05 x 10.2mm
2.8g typ.
Dimension Drawing (mm)
embossed Logo
Pinning information
19.65
7.05
Pin #
Single
Dual
+Vin
-Vin
-Vout
Com
+Vout
1
2
5
6
7
+Vin
-Vin
-Vout
no pin
+Vout
Marking
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
0.05
0.5+0.10/-0.05
0.25
Recommended Footprint Details
Bottom View
1 2
5 6 7
1 2
5 6 7
Top View
4 x 2.54 = 10.16
6 x 2.54 =15.24
2.54
2.00
www.recom-power.com
REV.: 5/2019
ECO-6
RKZ
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
INSTALLATION AND APPLICATION
IGBT Application Circuit
+
Q1
G
C
Signal+
IC1
R1
OUT
IN
IGBT Driver
-Vin
Signal-
+Vin
E
+Vout
IC2
DC
+Vin
-Vin
DC
C2
C1
C3
-Vout
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
tube
tube
Value
520.0 x 16.0 x 9.0mm
25pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95ꢀ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 5/2019
ECO-7
相关型号:
©2020 ICPDF网 联系我们和版权申明