中文:  中文翻译
下载:  下载PDF数据表文档文件
• Industry standard pinout  
• 1kVDC/1s or 2kVDC/1s isolation  
• UL94 V-0 package material  
• Fully encapsulated  
Features  
DC/DC Converter  
Unregulated  
Converters  
• Efficiency up to 85%  
RO  
R
Y
Description  
1 Watt  
SIP4  
3
wa  
t
The RO DC/DC converters are typically used in general purpose power isolation and voltage  
matching applications, and feature a full industrial operating temperature range of -40°C to +85°C  
without derating.  
r
n
a
Single Output  
Selection Guide  
Part  
Number  
nom. Input  
Voltage  
[VDC]  
Output  
Voltage  
[VDC]  
Output  
Current  
[mA]  
Efficiency  
typ. (1)  
[%]  
max. Capacitive  
Load (2)  
[µF]  
RO-xx3.3S (3,4)  
RO-xx05S (3,4)  
RO-xx09S (3,4)  
RO-xx12S (3,4)  
RO-xx15S (3,4)  
RO-xx24S (3,4)  
3.3, 5,12, 15, 24  
3.3, 5,12, 15, 24  
3.3, 5,12, 15, 24  
3.3, 5,12, 15, 24  
3.3, 5,12, 15, 24  
3.3, 5,12, 15, 24  
3.3  
5
303  
200  
111  
83  
75  
2200  
1000  
1000  
470  
78-80  
78-80  
80-84  
80-84  
78-85  
9
12  
15  
24  
66  
470  
42  
220  
Notes:  
Note1: Efficiency is tested at nominal input and full load at +25°C ambient  
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the  
capacitive load that will allow start up in under 1s without damage to the converter  
RoHS2  
+
REACH  
compliant  
compliant  
10 from 10  
E358085  
Model Numbering  
UL60950-1 certified  
CAN/CSA-C22.2 No 60950-1 certified  
EN60950-1 certified  
IEC60950-1 certified  
EN55032 compliant  
CB report  
RO- __ __S/_  
(3)  
“Protection  
Input Voltage  
(4)  
“Isolation Option  
Output Voltage  
Single  
Notes:  
Note3: standard part is without continuous short circuit protection  
add suffix „/P“ for continuous short circuit protection  
Note4: add suffix „/H“ for 2kVDC/1s isolation  
or add suffix „/HP“ for continuous short circuit protection and 2kVDC/1s isolation  
Ordering Examples:  
RO-123.3S/P: 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output with continuous short circuit protection  
RO-0509S/HP: 5VDC Input Voltage, 9VDC Output Voltage, Single Output with 2kVDC/1s Isolation and continuous short circuit protection  
www.recom-power.com  
REV.: 4/2020  
ECO-1  
RO  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
10ꢀ  
Max.  
Internal Input Filter  
Input Voltage Range  
Minimum Load  
capacitor  
0ꢀ  
Internal Operating Frequency  
Output Ripple and Noise  
50kHz  
100kHz  
105kHz  
20MHz BW  
100mVp-p  
Efficiency vs. Load  
RO-xx05S  
RO-xx12S  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
3.305  
0505  
1205  
3.312  
0512  
1212  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
RO-xx15S  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
3.315  
0515  
1215  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
REGULATIONS  
Parameter  
Output Accuracy  
Line Regulation  
Condition  
Value  
-2.0ꢀ typ. / 5.0ꢀ max.  
1.2ꢀ of 1.0ꢀ Vin typ.  
low line to high line  
continued on next page  
REV.: 4/2020  
www.recom-power.com  
ECO-2  
RO  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
Parameter  
Condition  
Value  
20.0ꢀ max.  
15.0ꢀ max.  
10.0ꢀ max.  
3.3Vout  
5Vout  
12, 15, 24Vout  
Load Regulation(5)  
10ꢀ to 100ꢀ load  
Notes:  
Note5: Operation below 10ꢀ load will not harm the converter, but specifications may not be met  
Tolerance Envelope  
RO-xx3.3S and RO-xx05S  
RO-xx12S and RO-xx15S  
+10%  
+7%  
+10%  
+5%  
+5%  
+5%  
Vnom  
Vnom  
-2%  
-5%  
-2%  
-5%  
10  
50  
100  
10  
50  
100  
Output Load [%]  
Output Load [%]  
Deviation vs. Load  
RO-xx05S  
RO-xx12S  
25  
20  
15  
10  
5
25  
20  
15  
10  
5
3.305  
0505  
1205  
3.312  
0512  
1212  
0
0
-5  
-5  
-10  
-10  
0
10 20 30 40 50 60 70 80 90 100  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
Output Load [%]  
RO-xx15S  
25  
20  
15  
10  
5
3.315  
0515  
1215  
0
-5  
-10  
0
10 20 30 40 50 60 70 80 90 100  
Output Load [%]  
www.recom-power.com  
REV.: 4/2020  
ECO-3  
RO  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
PROTECTIONS  
Parameter  
Type  
Value  
without suffix  
with suffix “/P”  
1 second  
continuous  
Short Circuit Protection (SCP)  
tested for 1 second  
rated for 1 minute  
1kVDC  
500VAC/60Hz  
without suffix  
Isolation Voltage (6)  
I/P to O/P  
with suffix  
“/H”  
tested for 1 second  
rated for 1 minute  
2kVDC  
1kVAC/60Hz  
10Gmin.  
Isolation Resistance  
Isolation Capacitance  
20pF min. / 75pF max.  
basic (IEC/EN60950-1)  
functional (IEC/EN60601-1)  
Insulation Grade  
Notes:  
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage  
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type  
ENVIRONMENTAL  
Parameter  
Condition  
full load (see graph)  
Value  
-40°C to +85°C  
+110°C  
Operating Temperature Range  
Maximum Case Temperature  
Temperature Coefficient  
Thermal Impedance  
0.03ꢀ/ꢁ typ.  
67ꢁ/W  
2000m (IEC/EN60950-1)  
3000m (IEC/EN60601-1)  
Operating Altitude  
Operating Humidity  
Pollution Degree  
non-condensing  
95ꢀ RH max.  
PD2  
+25°C  
+85°C  
11800 x 103 hours  
4800 x 103 hours  
MTBF  
according to MIL-HDBꢁ-217F, G.B.  
Derating Graph  
100  
90  
80  
70  
60  
50  
40  
30  
20  
10  
0
-40 -30 -20 -10  
0
10 20 30 40 50 60 70 80 90 100 110  
85  
Ambient Temperature [°C]  
www.recom-power.com  
REV.: 4/2020  
ECO-4  
RO  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Report / File Number  
Standard  
IEC60950-1:2005, 2nd Edition + A2:2013  
EN60950-1:2006 + A2:2013  
Information Technology Equipment, General Requirements for Safety  
LVD1602031  
UL60950-1, 2nd Edition:2007  
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007  
Information Technology Equipment, General Requirements for Safety  
Information Technology Equipment, General Requirements for Safety (CB)  
E358085-A4-UL  
E322406-A4-CB-1  
WD-SE-R-180677-A0  
RU-AT.49.09571  
IEC60950-1:2005, 2nd Edition  
Medical electrical equipment Part 1: General requirements for basic  
safety and essential performance  
EN60601-1:2006 + A12:2014  
IEC60601-1:2005 + A1:2012, 3rd Edition  
EAC  
TP TC 004/2011  
RoHS 2  
RoHS-2011/65/EU + AM-2015/863  
EMC Compliance  
Condition  
Standard / Criterion  
Electromagnetic compatibility of multimedia equipment -  
Emission requirements  
with external filter  
(see filter suggestion below)  
EN55032, Class A and B  
EMC Filter Suggestion according to EN55032  
C3  
L1  
+Vin  
+Vout  
+Vin  
+Vout  
C1  
C2  
-Vin  
-Vout  
-Vin  
-Vout  
C4  
Component List Class A  
Component List Class B  
MODEL  
C1  
L1  
C2  
C4 (safety)  
N/A  
MODEL  
C1  
L1  
C3 (safety) C4 (safety)  
RO-0505S  
RO-1205S  
RO-2405S  
RO-0505S  
RO-1205S  
RO-2405S  
10µF  
100V MLCC  
1nF  
50V MLCC  
10µF  
22µH choke  
N/A  
2.2nF  
1nF  
2.2nF  
100V MLCC RLS-226  
N/A  
Notes:  
Note8: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice  
DIMENSION AND PHYSICAL CHARACTERISTICS  
Parameter  
Type  
case  
potting  
PCB  
Value  
non-conductive black plastic, (UL94V-0)  
epoxy, (UL94V-0)  
Material  
FR4, (UL94V-0)  
Dimension (LxWxH)  
Weight  
11.5 x 6.0 x 10.0mm  
1.4g typ.  
continued on next page  
REV.: 4/2020  
www.recom-power.com  
ECO-5  
RO  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
Dimension Drawing (mm)  
embossed logo  
11.5  
6.0  
Pinning Information  
Pin #  
Single  
Marking  
1
2
3
4
-Vin  
+Vin  
-Vout  
+Vout  
0.05  
0.51+0.10/-0.05  
0.25  
Tolerance:  
xx.x= ±±.ꢀ55  
xx.xx= ±±.2ꢀ55  
Recommended Footprint Details  
1.90  
7.62  
2.54  
Top View  
1 2 3 4  
1 2 3 4  
Bottom View  
INSTALLATION AND APPLICATION  
Typical Application  
RO-0512S  
+Vin  
-Vin  
+Vout  
+12V  
+5V  
GND  
12V PIR  
Senor, IP  
-Vout  
Camera, etc.  
Single Board Computer  
(Raspberry Pi, Arduino,  
Beaglebone, etc.)  
Data  
PACKAGING INFORMATION  
Parameter  
Packaging Dimension (LxWxH)  
Packaging Quantity  
Type  
tube  
tube  
Value  
520.0 x 16.0 x 9.0mm  
42pcs  
Storage Temperature Range  
Storage Humidity  
-55°C to +125°C  
95ꢀ RH max.  
non-condensing  
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 4/2020  
ECO-6  

相关型号:

RO-1505SHP

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-1505SP

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-1509S

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-1509S/H

CONV DC/DC 1W 15VIN 09VOUT
ETC

RO-1509S/HP

CONV DC/DC 1W 15VIN 09VOUT
ETC

RO-1509SHP

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-1509SP

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-151.8S

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-151.8SHP

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-151.8SP

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-1512S

1 Watt SIP4 & SIP7 Single Output
RECOM

RO-1512S/H

CONV DC/DC 1W 15VIN 12VOUT
ETC