RO-1505S/P [ETC]
CONV DC/DC 1W 15VIN 05VOUT;型号: | RO-1505S/P |
厂家: | ETC |
描述: | CONV DC/DC 1W 15VIN 05VOUT |
文件: | 总6页 (文件大小:1634K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• Industry standard pinout
• 1kVDC/1s or 2kVDC/1s isolation
• UL94 V-0 package material
• Fully encapsulated
Features
DC/DC Converter
Unregulated
Converters
• Efficiency up to 85%
RO
R
Y
Description
1 Watt
SIP4
3
wa
t
The RO DC/DC converters are typically used in general purpose power isolation and voltage
matching applications, and feature a full industrial operating temperature range of -40°C to +85°C
without derating.
r
n
a
Single Output
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load (2)
[µF]
RO-xx3.3S (3,4)
RO-xx05S (3,4)
RO-xx09S (3,4)
RO-xx12S (3,4)
RO-xx15S (3,4)
RO-xx24S (3,4)
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3, 5,12, 15, 24
3.3
5
303
200
111
83
75
2200
1000
1000
470
78-80
78-80
80-84
80-84
78-85
9
12
15
24
66
470
42
220
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
RoHS2
+
REACH
compliant
compliant
10 from 10
E358085
Model Numbering
UL60950-1 certified
CAN/CSA-C22.2 No 60950-1 certified
EN60950-1 certified
IEC60950-1 certified
EN55032 compliant
CB report
RO- __ __S/_
(3)
“Protection
”
Input Voltage
(4)
“Isolation Option
”
Output Voltage
Single
Notes:
Note3: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Note4: add suffix „/H“ for 2kVDC/1s isolation
or add suffix „/HP“ for continuous short circuit protection and 2kVDC/1s isolation
Ordering Examples:
RO-123.3S/P: 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output with continuous short circuit protection
RO-0509S/HP: 5VDC Input Voltage, 9VDC Output Voltage, Single Output with 2kVDC/1s Isolation and continuous short circuit protection
www.recom-power.com
REV.: 4/2020
ECO-1
RO
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
10ꢀ
Max.
Internal Input Filter
Input Voltage Range
Minimum Load
capacitor
0ꢀ
Internal Operating Frequency
Output Ripple and Noise
50kHz
100kHz
105kHz
20MHz BW
100mVp-p
Efficiency vs. Load
RO-xx05S
RO-xx12S
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
0
3.305
0505
1205
3.312
0512
1212
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RO-xx15S
100
90
80
70
60
50
40
30
20
10
0
3.315
0515
1215
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
REGULATIONS
Parameter
Output Accuracy
Line Regulation
Condition
Value
-2.0ꢀ typ. / 5.0ꢀ max.
1.2ꢀ of 1.0ꢀ Vin typ.
low line to high line
continued on next page
REV.: 4/2020
www.recom-power.com
ECO-2
RO
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Parameter
Condition
Value
20.0ꢀ max.
15.0ꢀ max.
10.0ꢀ max.
3.3Vout
5Vout
12, 15, 24Vout
Load Regulation(5)
10ꢀ to 100ꢀ load
Notes:
Note5: Operation below 10ꢀ load will not harm the converter, but specifications may not be met
Tolerance Envelope
RO-xx3.3S and RO-xx05S
RO-xx12S and RO-xx15S
+10%
+7%
+10%
+5%
+5%
+5%
Vnom
Vnom
-2%
-5%
-2%
-5%
10
50
100
10
50
100
Output Load [%]
Output Load [%]
Deviation vs. Load
RO-xx05S
RO-xx12S
25
20
15
10
5
25
20
15
10
5
3.305
0505
1205
3.312
0512
1212
0
0
-5
-5
-10
-10
0
10 20 30 40 50 60 70 80 90 100
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
Output Load [%]
RO-xx15S
25
20
15
10
5
3.315
0515
1215
0
-5
-10
0
10 20 30 40 50 60 70 80 90 100
Output Load [%]
www.recom-power.com
REV.: 4/2020
ECO-3
RO
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
PROTECTIONS
Parameter
Type
Value
without suffix
with suffix “/P”
1 second
continuous
Short Circuit Protection (SCP)
tested for 1 second
rated for 1 minute
1kVDC
500VAC/60Hz
without suffix
Isolation Voltage (6)
I/P to O/P
with suffix
“/H”
tested for 1 second
rated for 1 minute
2kVDC
1kVAC/60Hz
10GΩ min.
Isolation Resistance
Isolation Capacitance
20pF min. / 75pF max.
basic (IEC/EN60950-1)
functional (IEC/EN60601-1)
Insulation Grade
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Condition
full load (see graph)
Value
-40°C to +85°C
+110°C
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
Thermal Impedance
0.03ꢀ/ꢁ typ.
67ꢁ/W
2000m (IEC/EN60950-1)
3000m (IEC/EN60601-1)
Operating Altitude
Operating Humidity
Pollution Degree
non-condensing
95ꢀ RH max.
PD2
+25°C
+85°C
11800 x 103 hours
4800 x 103 hours
MTBF
according to MIL-HDBꢁ-217F, G.B.
Derating Graph
100
90
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
www.recom-power.com
REV.: 4/2020
ECO-4
RO
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety
LVD1602031
UL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
Information Technology Equipment, General Requirements for Safety
Information Technology Equipment, General Requirements for Safety (CB)
E358085-A4-UL
E322406-A4-CB-1
WD-SE-R-180677-A0
RU-AT.49.09571
IEC60950-1:2005, 2nd Edition
Medical electrical equipment Part 1: General requirements for basic
safety and essential performance
EN60601-1:2006 + A12:2014
IEC60601-1:2005 + A1:2012, 3rd Edition
EAC
TP TC 004/2011
RoHS 2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(see filter suggestion below)
EN55032, Class A and B
EMC Filter Suggestion according to EN55032
C3
L1
+Vin
+Vout
+Vin
+Vout
C1
C2
-Vin
-Vout
-Vin
-Vout
C4
Component List Class A
Component List Class B
MODEL
C1
L1
C2
C4 (safety)
N/A
MODEL
C1
L1
C3 (safety) C4 (safety)
RO-0505S
RO-1205S
RO-2405S
RO-0505S
RO-1205S
RO-2405S
10µF
100V MLCC
1nF
50V MLCC
10µF
22µH choke
N/A
2.2nF
1nF
2.2nF
100V MLCC RLS-226
N/A
Notes:
Note8: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
potting
PCB
Value
non-conductive black plastic, (UL94V-0)
epoxy, (UL94V-0)
Material
FR4, (UL94V-0)
Dimension (LxWxH)
Weight
11.5 x 6.0 x 10.0mm
1.4g typ.
continued on next page
REV.: 4/2020
www.recom-power.com
ECO-5
RO
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Dimension Drawing (mm)
embossed logo
11.5
6.0
Pinning Information
Pin #
Single
Marking
1
2
3
4
-Vin
+Vin
-Vout
+Vout
0.05
0.51+0.10/-0.05
0.25
Tolerance:
xx.x= ±±.ꢀ55
xx.xx= ±±.2ꢀ55
Recommended Footprint Details
1.90
7.62
2.54
Top View
1 2 3 4
1 2 3 4
Bottom View
INSTALLATION AND APPLICATION
Typical Application
RO-0512S
+Vin
-Vin
+Vout
+12V
+5V
GND
12V PIR
Senor, IP
-Vout
Camera, etc.
Single Board Computer
(Raspberry Pi, Arduino,
Beaglebone, etc.)
Data
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
tube
tube
Value
520.0 x 16.0 x 9.0mm
42pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95ꢀ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2020
ECO-6
相关型号:
©2020 ICPDF网 联系我们和版权申明