RP10-2415DA/P-HC [ETC]

CONV DC/DC 10W 18-36VIN +/-15VOU;
RP10-2415DA/P-HC
型号: RP10-2415DA/P-HC
厂家: ETC    ETC
描述:

CONV DC/DC 10W 18-36VIN +/-15VOU

文件: 总8页 (文件大小:570K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
• 2:1 input voltage range  
• 1.6kVDC isolation  
Features  
DC/DC Converter  
• UL certified  
• Efficiency up to 91%  
• Six-sided continuous shield  
• No minimum load required  
Regulated  
Converter  
RP10-A  
10 Watt  
1“ x 1“  
Single and Dual  
Output  
Description  
3
The RP10-A series are wide input voltage range 1”x1” power DC/DC converters. Despite their small  
size, the RP10-A converters are fully specified devices with built-in Class A EMC filters, no minimum  
load, 1.6kVDC isolation, under-voltage lockout and low ripple/noise figures. The outputs are fully  
protected against short circuits, overcurrent and overvoltage and can be trimmed over a 10ꢀ range.  
The RP10-A series will find many uses in applications where board space is at a premium as no  
external components are required.  
Selection Guide  
Part Number  
Input  
Output  
Voltage Range Voltage  
Output  
Current  
[mA]  
3000  
2000  
830  
670  
416  
3000  
2000  
830  
670  
416  
3000  
2000  
830  
670  
416  
1000  
416  
333  
Input (1) Efficiency (1) Max. Capacitive  
Current  
[mA]  
typ.  
[%]  
Load (2)  
[µF]  
3500  
2500  
430  
350  
125  
3500  
2500  
430  
350  
125  
3500  
2500  
430  
350  
125  
1440  
250  
180  
[VDC]  
9-18  
9-18  
9-18  
9-18  
[VDC]  
3.3  
5
12  
15  
24  
3.3  
5
12  
15  
24  
3.3  
5
12  
15  
24  
5
RP10-123.3SA (2,3)  
RP10-1205SA (2,3)  
RP10-1212SA (2,3)  
RP10-1215SA (2,3)  
RP10-1224SA (2,3)  
RP10-243.3SA (2,3)  
RP10-2405SA (2,3)  
RP10-2412SA (2,3)  
RP10-2415SA (2,3)  
RP10-2424SA (2,3)  
RP10-483.3SA (2,3)  
RP10-4805SA (2,3)  
RP10-4812SA (2,3)  
RP10-4815SA (2,3)  
RP10-4824SA (2,3)  
RP10-1205DA (2,3)  
RP10-1212DA (2,3)  
RP10-1215DA (2,3)  
RP10-2405DA (2,3)  
RP10-2412DA (2,3)  
RP10-2415DA (2,3)  
RP10-4805DA (2,3)  
RP10-4812DA (2,3)  
RP10-4815DA (2,3)  
994  
969  
933  
931  
914  
485  
484  
456  
465  
457  
243  
239  
230  
233  
229  
969  
935  
925  
484  
462  
463  
239  
229  
231  
83  
86  
89  
90  
91  
85  
86  
91  
90  
91  
85  
87  
90  
90  
91  
86  
89  
90  
86  
90  
90  
87  
91  
90  
9-18  
18-36  
18-36  
18-36  
18-36  
18-36  
36-75  
36-75  
36-75  
36-75  
36-75  
9-18  
RoHS2  
+
REACH  
compliant  
compliant  
10 from 10  
E196683  
UL60950-1 certified  
EN55032 compliant  
9-18  
9-18  
12  
15  
5
12  
15  
5
18-36  
18-36  
18-36  
36-75  
36-75  
36-75  
1000  
416  
333  
1000  
416  
333  
1440  
250  
180  
1440  
250  
180  
12  
15  
Notes:  
Note1: Maximum values at nominal input voltage and full load  
Note2: Max. Cap load is tested at nominal input and full resistive load  
Model Numbering  
RP10-__ __ _A/_-_  
“Package (4)”  
nom. Input Voltage  
nom. Output Voltage  
“CTRL Logic (3)”  
Single or Dual  
Notes:  
Note3: add suffix ”P” for CTRL function with positive logic (1=ON, 0=OFF) and Trim pin  
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF) and Trim pin  
or add suffix “XC” for omitted CTRL pin and Trim pin (refer to “Dimension Drawing (mm)”)  
Note4: add suffix “-HC” for premounted Heat-sink with clamps  
Ordering Examples  
RP10-1205SA/P = 12V input, 5V output, single, positive Logic CTRL pin  
RP10-4805DA/XC-HC = 48V input, 5V output, dual, without CTRL pin, Heat-sink premounted  
www.recom-power.com  
REV.: 6/2020  
PD-1  
RP10-A  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
BASIC CHARACTERISTICS  
Parameter  
Condition  
Min.  
Typ.  
Max.  
Internal Input Filter  
Pi-Type  
nom. Vin = 12VDC  
nom. Vin = 24VDC  
nom. Vin = 48VDC  
9VDC  
18VDC  
36VDC  
12VDC  
24VDC  
48VDC  
18VDC  
36VDC  
75VDC  
25VDC  
50VDC  
100VDC  
9VDC  
Input Voltage Range  
Input Surge Voltage  
nom. Vin = 12VDC  
nom. Vin = 24VDC  
nom. Vin = 48VDC  
DC-DC ON  
1s max.  
nom. Vin = 12VDC  
nom. Vin = 24VDC  
DC-DC OFF  
8VDC  
16VDC  
33VDC  
DC-DC ON  
DC-DC OFF  
18VDC  
36VDC  
Under Voltage Lockout (UVLO)  
DC-DC ON  
DC-DC OFF  
nom. Vin = 48VDC  
refer to  
3.3Vout, 12Vout  
Others  
-10%  
-10%  
+10%  
+20%  
Output Voltage Trimming  
Minimum Load  
“OUTPUT VOLTAGE TRIMMING”  
0%  
Power up  
ON/OFF CTRL  
30ms  
30ms  
Start-up Time  
DC-DC ON  
DC-DC OFF  
Open or 3.0VDC < VCTRL< 15VDC  
Short or 0VDC < VCTRL< 1.2VDC  
Positive Logic  
Negative Logic  
ON/OFF CTRL (5)  
refer to “ON/OFF CTRL”  
DC-DC ON  
DC-DC OFF  
Short or 0VDC < VCTRL< 1.2VDC  
Open or 3.0VDC < VCTRL< 15VDC  
+1.0mA  
drive current  
DC-DC OFF  
-0.5mA  
297kHz  
Input Current of CTRL pin  
Standby Current  
ICTRL  
IIn  
2.5mA  
Internal Operating Frequency  
330kHz  
363kHz  
measured at 20MHz BW,  
with a 10µF/25V X7R 1206 MLCC  
3.3Vout, 5Vout  
12Vout, 15Vout  
40mVp-p  
60mVp-p  
Output Ripple and Noise  
measured at 20MHz BW,  
24Vout  
60mVp-p  
30mAp-p  
with a 1µF/50V X7R 1206 MLCC  
Input Reflected Ripple Current  
Notes:  
Note5: If suffix “XC” is specified, the control pin will be absent. If fitted, the ON/OFF control function  
can be positive or negative logic. The pin voltage is referenced to -Vin  
RP10-2405SA  
Efficiency vs. Input Voltage full load  
Efficiency vs. Output Current  
90  
85  
80  
75  
70  
65  
60  
95  
90  
85  
80  
75  
70  
65  
60  
55  
50  
45  
40  
18Vin  
24Vin  
30Vin  
36Vin  
10  
20  
30  
40  
50  
60  
70  
80  
90  
100  
18  
20  
22  
24  
26  
28  
30  
32  
34  
36  
Output Current [%]  
Input Voltage [VDC]  
www.recom-power.com  
REV.: 6/2020  
PD-2  
RP10-A  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
ON/OFF CTRL  
IIN  
+Vin  
+Vout  
+Vin  
+Vout  
DC-DC ON  
DC-DC OFF  
Open or 3.0VDC < VCTRL < 15VDC  
Short or 0VDC < VCTRL < 1.2VDC  
Positve Logic  
Negativ Logic  
ICTRL  
CTRL  
-Vin  
VCTRL  
DC-DC ON  
DC-DC OFF  
Short or 0VDC < VCTRL < 1.2VDC  
Open or 3.0VDC < VCTRL < 15VDC  
-Vout  
-Vin  
-Vout  
OUTPUT VOLTAGE TRIMMING  
Output Voltage Trimming  
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external  
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for choosing these  
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor  
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.  
Trim up  
Trim down  
-Vout  
Trim  
R
R
D
U
+Vout  
Trim  
RP10-xx3.3SA  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
3.333  
3.366  
191.511  
3.399  
126.990  
3.432  
94.730  
3.465  
3.498  
3.531  
3.564  
46.340  
3.597  
40.963  
3.63  
385.071  
75.374  
62.470  
53.253  
36.662  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
3.267  
116.719  
3.234  
54.779  
3.201  
34.133  
3.168  
23.810  
3.135  
17.616  
3.102  
13.486  
3.069  
10.537  
3.036  
8.325  
3.003  
6.604  
2.97  
5.228  
RP10-xx05SA  
Trim up  
[%]  
[VDC]  
[kW]  
1
2
3
4
5
6
7
8
9
10  
Vout =  
5.05  
5.10  
5.15  
5.20  
5.25  
5.30  
5.35  
5.4  
5.45  
5.50  
RU =  
253.450  
125.700  
83.117  
61.825  
49.050  
40.533  
34.450  
29.888  
26.339  
23.500  
[%]  
[VDC]  
[kW]  
Trim up  
Vout =  
RU =  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
5.55  
5.60  
5.65  
5.70  
5.75  
5.80  
5.85  
5.90  
5.95  
6.00  
21.177  
19.242  
17.604  
16.200  
14.983  
13.919  
12.979  
12.144  
11.397  
10.725  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
4.95  
4.90  
4.85  
4.80  
4.75  
4.70  
4.65  
4.60  
4.55  
4.50  
248.340  
120.590  
78.007  
56.715  
43.940  
35.423  
29.340  
24.778  
21.229  
18.390  
RP10-xx12SA  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
12.12  
12.24  
99.057  
12.36  
64.334  
12.48  
46.973  
12.60  
36.557  
12.72  
29.612  
12.84  
24.652  
12.96  
20.932  
13.08  
18.038  
13.20  
15.723  
203.223  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
11.88  
776.557  
11.76  
380.723  
11.64  
248.779  
11.52  
182.807  
11.40  
11.28  
116.834  
11.16  
97.985  
11.04  
83.848  
10.92  
72.853  
10.8  
143.223  
64.057  
continued on next page  
REV.: 6/2020  
www.recom-power.com  
PD-3  
RP10-A  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
RP10-xx15SA  
[%]  
[VDC]  
[kW]  
Trim up  
Vout =  
RU =  
1
2
3
4
5
6
7
8
9
10  
15.15  
161.557  
15.30  
78.223  
15.45  
50.446  
15.60  
36.557  
15.75  
28.223  
15.90  
22.668  
16.05  
18.700  
16.20  
15.723  
16.35  
13.409  
16.50  
11.557  
[%]  
[VDC]  
[kW]  
Trim up  
Vout =  
RU =  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
16.65  
10.042  
16.80  
8.779  
16.95  
7.711  
17.10  
6.795  
17.25  
6.001  
17.40  
5.307  
17.55  
4.694  
17.70  
4.149  
17.85  
3.662  
18.00  
3.223  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
14.85  
818.223  
14.70  
401.557  
14.55  
262.668  
14.40  
193.223  
14.25  
151.557  
14.10  
123.779  
13.95  
103.938  
13.80  
89.057  
13.65  
77.483  
13.50  
68.223  
RP10-xx24SA  
[%]  
[VDC]  
[kW]  
Trim up  
1
2
3
4
5
6
7
8
9
10  
Vout =  
RU =  
24.24  
24.48  
278.667  
24.72  
181.444  
24.96  
132.833  
25.20  
13.667  
25.44  
84.222  
25.68  
70.333  
25.92  
59.917  
26.16  
51.815  
26.40  
45.333  
570.333  
[%]  
[VDC]  
[kW]  
Trim up  
Vout =  
RU =  
11  
12  
13  
14  
15  
16  
17  
18  
19  
20  
26.64  
40.030  
26.88  
35.611  
27.12  
31.872  
27.36  
28.667  
27.60  
25.889  
27.84  
23.458  
28.08  
21.314  
28.32  
19.407  
28.56  
17.702  
28.80  
16.167  
[%]  
[VDC]  
[kW]  
Trim down  
Vout =  
RD =  
1
2
3
4
5
6
7
8
9
10  
23.76  
23.52  
23.28  
23.04  
22.80  
22.56  
767.111  
22.32  
647.667  
22.08  
558.083  
21.84  
488.407  
21.60  
4947.667 2439.333 1603.222 1185.167 934.333  
432.667  
REGULATIONS  
Parameter  
Condition  
Value  
Output Accuracy  
1.0%  
low line to high line,  
Single  
Dual  
0.2%  
0.5%  
Line Regulation  
Load Regulation  
full load  
Single  
Dual  
0.2%  
1.0%  
0% to 100% load  
Single  
Dual  
0.1%  
0.8%  
10% to 90% load  
Cross Regulation  
asymmetrical 25%<>100% load  
25% load step change  
5.0%  
Transient Response Recovery Time  
250µs typ.  
www.recom-power.com  
REV.: 6/2020  
PD-4  
RP10-A  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
PROTECTIONS  
Parameter  
Condition  
Value  
Short Circuit Protection (SCP)  
continuous, automatic recovery  
3.3Vout  
5Vout  
3.7 - 5.4VDC  
6.3 - 7.4VDC  
Over Voltage Protection (OVP)  
zener diode clamp  
12Vout  
15Vout  
24Vout  
13.5 - 19.6VDC  
18.3 - 22.0VDC  
29.1 - 32.5VDC  
Over Load Protection (OLP)  
Isolation Voltage(6)  
% of Iout rated  
150% typ., Hiccup mode  
I/P to O/P  
I/P to O/P to case  
1.6kVDC/ 1 minute  
1.0kVDC/ 1 minute  
1GW min.  
Isolation Resistance  
Isolation Capacitance  
Viso= 500VDC  
1500pF max.  
Notes:  
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage  
Note7: This power module is not internally fused. An input line fuse must always be used  
Recom suggests: 12Vin= T2A; 24Vin= T1A; 48Vin= T0.5A slow blow types  
ENVIRONMENTAL  
Parameter  
Condition  
Value  
-40°C to +78°C  
-40°C to +100°C  
without derating  
with derating  
Operating Temperature Range  
Maximum Case Temperature  
Temperature Coefficient  
+105°C  
0.02%/ꢀ max.  
@ natural convection  
0.1m/s, vertical direction  
without heat-sink  
with heat-sink  
18.2ꢀ/W  
15.8ꢀ/W  
Thermal Impedance  
Operating Humidity  
Thermal Shock  
Vibration  
non-condensing  
5% - 95% RH  
according to MIL-STD-810F  
according to MIL-STD-810F  
3308 x 103 hours  
MTBF  
according to MIL-HDBꢀ-217F, G.B.  
+25°C  
Derating Graph (8)  
RP10-2405SA  
RP10-2405SA-HC  
100  
80  
60  
40  
20  
0
100  
80  
60  
40  
20  
0
-40 -20  
0
20 40  
60 78 80 100  
-40 -20  
0
20 40  
60  
80 100  
Ambient Temperature [°8C1]  
Ambient Temperature [°C]  
Notes:  
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number  
not shown here please contact RECOM Techsupport for detailed information  
www.recom-power.com  
REV.: 6/2020  
PD-5  
RP10-A  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
SAFETY AND CERTIFICATIONS  
Certificate Type (Safety)  
Condition  
E196683  
Standard  
UL60950-1, 1st Edition  
CAN/CSA-C22.2 No. 60950-1, 1st Edition  
Information Technology Equipment, General Requirements for Safety  
EAC  
RU-AT.49.09571  
TP TC 004/2011  
RoHS2+  
RoHS-2011/65/EU + AM-2015/863  
EMC Compliance  
Condition  
Standard / Criterion  
Electromagnetic compatibility of multimedia equipment - Emission  
requirements  
without external filter  
refer to “EMC Filtering Suggestions”  
EN55032, Class A  
EN55032, Class B  
ESD Electrostatic discharge immunity test  
Radiated, radio-frequency, electromagnetic field immunity test  
Fast Transient and Burst Immunity (9)  
Surge Immunity (9)  
Air 8kV and Contact 6kV  
EN61000-4-2, Criteria A  
EN61000-4-3, Criteria A  
EN61000-4-4, Criteria A  
EN61000-4-5, Criteria A  
EN61000-4-6, Criteria A  
EN61000-4-8, Criteria A  
10V/m  
2kV  
1kV  
3Vr.m.s  
Immunity to conducted disturbances, induced by radio-frequency fields  
Power Magnetic Field Immunity  
100A/m continuous; 1000A/m 1s  
Notes:  
Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5  
Recom suggests Nippon chemi-con ꢀY series 220µF/100V  
EMC Filtering Suggestions according to EN55032  
Single  
Dual  
F1  
F1  
+Vin  
+Vout  
+Vin  
-Vin  
+Vout  
Com  
-Vout  
+Vin  
+Vout  
+Vin  
-Vin  
+Vout  
C1  
C1  
Com  
-Vout  
-Vin  
-Vout  
-Vin  
-Vout  
Component List Class B  
MODEL  
C1  
RP10-12xxSA, RP10-12xxDA  
RP10-24xxSA, RP10-24xxDA  
RP10-48xxSA, RP10-48xxDA  
10µF/25V, 1812 MLCC  
6.8µF/50V, 1812 MLCC  
4.7µF/100V, 1812 MLCC  
DIMENSIONS AND PHYSICAL CHARACTERISTICS  
Parameter  
Type  
case  
base  
Value  
copper alloy C2680  
FR4 PCB  
Material  
potting  
epoxy (UL94 V-0)  
25.4 x 25.4 x 9.9mm  
31.4 x 25.4 x 16.5mm  
without Heat-sink  
with Heat-sink  
Dimensions (LxWxH)  
Weight  
without Heat-sink  
with Heat-sink  
16.5g  
23g  
continued on next page  
REV.: 6/2020  
www.recom-power.com  
PD-6  
RP10-A  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
Dimension Drawing (mm)  
Pinning Information  
25.4  
25.4  
Pin # Single  
Dual  
+Vin  
-Vin  
“/XC“  
+Vin  
-Vin  
1
2
3
4
5
6
+Vin  
-Vin  
CTRL (3) CTRL (3) no Pin (3)  
+Vout  
Trim  
+Vout  
Com  
+Vout  
Trim  
2.54  
0.1  
8 x 2.54= 20.32  
Ø 1.0  
-Vout  
-Vout  
-Vout  
Recommended Footprint Details  
2.54  
Pin Pitch Tolerance 0.25mm  
Tolerance: xx.x= ±±.ꢀ55  
xx.xx= ±±.ꢁꢀ55  
3
6
5
4
4
5
6
2
1
1 Bottom View  
Top View  
2
3
Dimension Drawing with Heat-sink (mm)  
25.4  
Top View  
Heat-sink  
Pinning Information  
31.4  
24.2  
Pin # Single  
Dual  
“/XC“  
+Vin  
-Vin  
1
2
3
4
5
6
+Vin  
+Vin  
-Vin  
-Vin  
CTRL (3) CTRL (3) no Pin (3)  
+Vout  
Trim  
+Vout  
Com  
+Vout  
Trim  
0.1  
2.54  
Ø 1.0  
-Vout  
-Vout  
-Vout  
8 x 2.54= 20.32  
Recommended Footprint Details  
Pin Pitch Tolerance 0.25mm  
Tolerance: xx.x= ±±.ꢀ55  
xx.xx= ±±.ꢁꢀ55  
2.54  
3
6
5
4
4
2
1
1 Bottom View  
5
Top View  
2
3
6
www.recom-power.com  
REV.: 6/2020  
PD-7  
RP10-A  
DC/DC Converter  
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)  
Series  
PACKAGING INFORMATION  
Parameter  
Type  
Value  
tube  
tray  
without heat-sink  
with heat-sink  
257.0 x 28.5 x 21.0mm  
230.0 x 180.0 x 28.0mm  
Packaging Dimension (LxWxH)  
tube  
tray  
without heat-sink  
with heat-sink  
8pcs  
20pcs  
Packaging Quantity  
Storage Temperature Range  
Storage Humidity  
-55°C to +125°C  
5% - 95% RH  
non-condensing  
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The  
products are not authorized for use in safety-critical applications without RECOMꢁs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause  
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized  
use of RECOM products in such safety-critical applications.  
www.recom-power.com  
REV.: 6/2020  
PD-8  

相关型号:

RP10-2415DA/XC

CONV DC/DC 10W 18-36VIN +/-15VOU
ETC

RP10-2415DA/XC-HC

CONV DC/DC 10W 18-36VIN +/-15VOU
ETC

RP10-2415DAW

10 Watt Single & Dual Output
RECOM

RP10-2415DAW/N

CONV DC/DC 10W 9-36VIN +/-15VOUT
ETC

RP10-2415DAW/N-HC

CONV DC/DC 10W 9-36VIN +/-15VOUT
ETC

RP10-2415DAW/P-HC

CONV DC/DC 10W 9-36VIN +/-15VOUT
ETC

RP10-2415DAW/XC

CONV DC/DC 10W 9-36VIN +/-15VOUT
ETC

RP10-2415DAW/XC-HC

DC DC CONVERTER +/-15V 10W
ETC

RP10-2415DE

10 Watt 2inch x 1inch Package Single & Dual Output
RECOM

RP10-2415DE-HC

CONV DC/DC 10W 18-36VIN +/-15V
ETC

RP10-2415DE/M1

CONV DC/DC 10W 18-36VIN +/-15V
ETC

RP10-2415DE/M1-HC

CONV DC/DC 10W 18-36VIN +/-15V
ETC