RP100H-11005SRW/N-HC [ETC]
CONV DC/DC 100W 43-160VIN 05VOUT;型号: | RP100H-11005SRW/N-HC |
厂家: | ETC |
描述: | CONV DC/DC 100W 43-160VIN 05VOUT |
文件: | 总16页 (文件大小:4789K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 4:1 wide input range
Features
• 3kVAC reinforced insulation for 110Vin
2.25kVDC basic insulation for 24Vin & 48Vin
• Efficiency up to 93%
DC/DC Converter
Regulated
Converter
• No minimum load required
• EN50155, IEC/EN60950-1 & UL60950-1 certified
RP100H-RW
Description
100 Watt
Half Brick
Single Output
The half-brick RP100H series DC/DC converters are designed for railway rolling stock and high voltage battery
applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to
160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal base-
plates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink).
The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock
and vibration environments. The converters are EN50155, UL60950 and IEC/EN60950 certified. The RP100H-RW
series have a three year warranty.
3
Selection Guide
Part Number
Input
Output
Output Input(1) Output Efficiency(1) Max. Capacitive
Voltage Range Voltage Current Current Power
typ.
[%]
Load
[µF]
[VDC]
9-36
[VDC]
5
[mA]
20000
8400
6700
4200
2100
20000
8400
6700
4200
2100
20000
8400
6700
4200
2100
[mA]
4480
4666
4601
4666
4666
2240
2333
2300
2333
2307
1010
1018
1015
1018
1007
[W]
100
101
100
101
101
100
101
100
101
101
100
101
100
101
101
RP100H-2405SRW
RP100H-2412SRW
RP100H-2415SRW
RP100H-2424SRW
RP100H-2448SRW
RP100H-4805SRW
RP100H-4812SRW
RP100H-4815SRW
RP100H-4824SRW
RP100H-4848SRW
93
90
91
90
90
93
90
91
90
90
93
90
91
90
90
40000
7000
4460
1750
430
40000
7000
4460
1750
430
40000
7000
4460
1750
430
RoHS2
+
REACH
compliant
compliant
9-36
9-36
9-36
9-36
16.5-75
16.5-75
16.5-75
16.5-75
16.5-75
12
15
24
48
5
12
15
24
48
5
10 from 10
E196683
EN50155 certified
IEC/EN60950-1 certified
UL60950-1 certified
RP100H-11005SRW 43-160
RP100H-11012SRW 43-160
RP100H-11015SRW 43-160
RP100H-11024SRW 43-160
RP100H-11048SRW 43-160
12
15
24
48
Notes:
Note1: Efficiency is tested by nominal Vin, full load and at 25°C
Model Numbering
REF
DESIGN
available
RP100H-__ __ SRW/_ _
Package(3)
CTRL Logic(2)
Input Voltage
Output Voltage
Single
https://recom-power.com/rec-s-R-
REF04-RIA12.html
Notes:
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
SURGE
PROTECTOR
available
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
(4)
for more details refer to “ON/OFF CTRL
”
Note3: add suffix “-HC” for premounted Heat-sink (refer to “Dimension Drawing Heat-sink (mm)”)
(compatible with all other suffixes)
Ordering Examples
RP100H-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function
RP100H-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RP100H-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, premounted Heat-sink
https://recom-power.com/rec-s-
RSPxxx-168.html
www.recom-power.com
REV.: 4/2020
PA-1
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
Pi-Type
nom Vin = 24V
nom Vin = 48V
nom Vin = 110V
Vin = 24V, 1s max.
Vin = 48V, 1s max.
Vin = 110V, 1s max.
9VDC
16.5VDC
43VDC
24VDC
48VDC
110VDC
36VDC
75VDC
160VDC
50VDC
100VDC
185VDC
9VDC
Input Voltage Range
Input Surge Voltage
DC-DC ON
DC-DC OFF
Vin = 24V
7.3VDC
8.1VDC
DC-DC ON
DC-DC OFF
18VDC
16.3VDC
Under Voltage Lockout (UVLO)
Quiescent Current
Vin = 48V
15.5VDC
DC-DC ON
DC-DC OFF
43VDC
36.0VDC
35mA
Vin = 110V
33.0VDC
25mA
15mA
Vin = 24V
Vin = 48V
Vin = 110V
25mA
10mA
Output Voltage Trimming
Minimum Load
refer to “OUTPUT VOLTAGE TRIMMING”
-20%
0%
+10%
Power up
Remote ON/OFF
75ms
75ms
Start-up time
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Positive Logic
Negative Logic
ON/OFF CTRL (4)
refer to “ON/OFF CTRL”
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
Input Current of CTRL pin
Standby Current
drive current
DC-DC OFF
ICTRL
IIn
-0.5mA
1mA
3mA
Vin = 24V, Vin =48V
Vin = 110V
225kHz
270kHz
250kHz
300kHz
275kHz
330kHz
Internal Operating Frequency
with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap
with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap 12, 15Vout
5 Vout
75mVp-p
100mVp-p
200mVp-p
300mVp-p
Measured by
20MHz BW
Output Ripple and Noise
Remote Sense
with a 4.7µF/50V X7R MLCC
with a 2.2µF/100V X7R MLCC
24Vout
48Vout
% of nom Vout (refer to “REMOTE SENSE”)
10%
Notes:
Note4: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin
RP100H-2405SRW
Efficiency vs. Output Current
Efficiency vs. Input Voltage
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
100% Load
50% Load
25% Load
9Vin
24Vin
36Vin
12
15
18
21
24
27
30
33
9
36
10
20
30
40
50
60
70
80
90
100
Input Voltage [V]
Output Current [%]
continued on next page
REV.: 4/2020
www.recom-power.com
PA-2
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-2405SRW
Typical Output Ripple and Noise/full load
Power Dissipation vs. Output Current
18
15
12
9
6
9Vin
24Vin
36Vin
3
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start-up Rise Characteristic
Power up Start-up Characteristic
RP100H-4805SRW
Efficiency vs. Output Current
Efficiency vs. Input Voltage
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
100% Load
50% Load
25% Load
16.5Vin
48Vin
75Vin
10
20
30
40
50
60
70
80
90
100
24
30
36
42
48
54
60
66
16.5
75
72
Output Current [%]
Input Voltage [V]
continued on next page
REV.: 4/2020
www.recom-power.com
PA-3
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-4805SRW
Power Dissipation vs. Output Current
Typical Output Ripple and Noise/full load
18
15
12
9
6
3
16.5Vin
48Vin
75Vin
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start-up Rise Characteristic
Power up Start-up Characteristic
RP100H-11005SRW
Efficiency vs. Output Current
Efficiency vs. Input Voltage
100
90
80
70
60
50
40
30
20
10
0
100
90
80
70
60
50
40
30
20
10
100% Load
50% Load
25% Load
43Vin
110Vin
160Vin
43
60
65
80
95
110 125 140 155 160
10
20
30
40
50
60
70
80
90
100
Input Voltage [V]
Output Current [%]
continued on next page
REV.: 4/2020
www.recom-power.com
PA-4
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-11005SRW
Power Dissipation vs. Output Current
Typical Output Ripple and Noise
18
15
12
9
6
43Vin
110Vin
160Vin
3
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start-up Rise Characteristic
Power up Start-up Characteristic
ON/OFF CTRL
IIN
+Vin
+Vout
+Vin
+Vout
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Positve Logic
Negativ Logic
ICTRL
CTRL
-Vin
VCTRL
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
-Vout
-Vin
-Vout
REMOTE SENSE
RW1
+Vout
+Vin
+Sense
The output voltage can be adjusted by both trim and remote sense. The
maximum combined adjustment range 10%. Derate the maximum out-
put power if using the trim or sense function.
R1
R2
Trim
R
R
... wire losses +
... wire losses -
W1
W2
1
-Sense
R ... trim up resistor
-Vin
-Vout
(GND)
R ... trim down resistor
2
RW2
www.recom-power.com
REV.: 4/2020
PA-5
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
RP100H-RW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim
resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may
slightly vary; they also can be calculated with below shown equation.
TRIM UP
TRIM DOWN
TRIM
-Sense
R
R
2
1
+Sense
TRIM
Trim Calculation
Vout
=
=
=
=
Output Voltage
100*Vout+DVout * Vout)
(100+2DVout)
DVout
R1 =
R2 =
-
kΩ
DVout
R1
Output Voltage Trim in %
trim up resistor
1.225*DVout
R2
trim down resistor
100
- 2 kΩ
DVout
Practical Example:
Trim Up:
Vout = 5V, DVout = 10% (5.5V)
100*Vout+DVout * Vout)
(100+2DVout)
DVout
100*5 +10*5 100+2*10
R1 =
-
kΩ =
-
= 44.89 - 12 = 32.9kΩ
1.225*DVout
1.225*10
10
Trim down:
Vout = 5V, DVout = -10% (4.5V)
100
100
10
R2 =
- 2 kΩ =
- 2 = 8.06kΩ
DVout
RP100H-xx05SRW
Trim up
Vout =
R1 =
1
2
3
4
5
6
7
8
9
10
%
5.05
309
5.10
158
5.15
5.20
78.7
5.25
63.4
5.30
53.6
5.35
46.4
5.4
5.45
36.5
5.50
33.2
Volts
kOhms
105
40.2
RP100H-xx12SRW
Trim up
Vout =
R1 =
1
2
3
4
5
6
7
8
9
10
%
12.12
887
12.24
453
12.36
301
12.48
226
12.60
182
12.72
154
12.84
133
12.96
118
13.08
105
13.20
95.3
Volts
kOhms
RP100H-xx15SRW
Trim up
Vout =
R1 =
1
2
3
4
5
6
7
8
9
10
%
15.15
1130
15.30
576
15.45
383
15.60
294
15.75
237
15.90
196
16.05
169
16.20
150
16.35
137
16.50
124
Volts
kOhms
continued on next page
REV.: 4/2020
www.recom-power.com
PA-6
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
OUTPUT VOLTAGE TRIMMING
RP100H-xx24SRW
Trim up
Vout =
RU =
1
2
3
4
5
6
7
8
9
10
%
24.24
1870
24.48
953
24.72
634
24.96
487
25.20
392
25.44
324
25.68
280
25.92
249
26.16
226
26.40
205
Volts
kOhms
RP100H-xx48SRW
Trim up
Vout =
R1 =
1
2
3
4
5
6
7
8
9
10
%
48.48
3830
48.96
1960
49.44
1300
49.92
1000
50.40
806
50.88
681
51.36
576
51.84
511
52.32
464
52.80
422
Volts
kOhms
Trim Down all Vout‘s
Trim down
1
2
3
4
5
6
7
8
9
10
%
R2 =
97.6
47.5
31.6
23.2
17.8
14.7
12.1
10.5
9.09
8.06
kOhms
Trim down
R2 =
11
12
13
14
15
16
17
18
19
20
%
7.15
6.34
5.76
5.11
4.64
4.22
3.92
3.57
3.24
3.01
kOhms
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation
Transient Response
1.0%
0.1%
0.1%
low line to high line at full load
0% to 100% load
25% load step change
200µs typ.; 250µs max.
Transient Response to Dynamic Load Change from 100% to 75% to 100% of Full Load at nom.Vin
RP100H-2405SRW RP100H-4805SRW
continued on next page
REV.: 4/2020
www.recom-power.com
PA-7
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-11005SRW
PROTECTIONS
Parameter
Condition
below 100mΩ
% of nom. Vout
Value
continuous, automatic recovery
115%-130%, Hiccup Mode
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
24Vin, 48Vin
110Vin
120%-150%, Hiccup Mode
150% typ., Hiccup Mode
Over Load Protection (OLP)
% Iout rated
Over Temperature Protection (OTP)
+110°C to +120°C
I/P to O/P
I/P or O/P to Case
3kVAC/1minute
1.5kVAC/1minute
110Vin
Isolation Voltage
I/P to O/P
I/P or O/P to Case
2.25kVDC/1minute
1.6kVDC/1minute
24Vin, 48Vin
Isolation Resistance
Isolation Capacitance
500 VDC
110 Vin
1GΩ min.
2500pF max.
reinforced insulation
basic insulation
Isolation Grade
24Vin, 48Vin
Notes:
Note5: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T35A slow blow.
ENVIRONMENTAL
Parameter
Condition
Value
refer to derating graph
105°C
Operating Case Temperature Range
Maximum Case Temperature
Temperature Coefficient
0.02%/°C max.
vertical direction by natural convection (0.1m/s) without Heat-sink
vertical direction by natural convection (0.1m/s) with Heat-sink
6.7°C/W
4.7°C/W
Thermal Impedance
Operating Humidity
Pollution Degree
Shock
5% - 95% RH
PD2
according to EN61373 standard
according to MIL-STD-810F standard
according to EN61373 standard
according to EN45545-2, 2013 standard
408.7 x 103 hours
Thermal Shock
Vibration
Fire protection on railway vehicles
MTBF
according to MIL-HDBK-217F standard, 25°C
continued on next page
REV.: 4/2020
www.recom-power.com
PA-8
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Thermal Calculation
Rthcase-ambient = 6.7°C/W (vertical)
Tcase
=
=
=
=
=
=
=
Case Temperature
Environment Temperature
Internal losses
Input Power
Output Power
Rthcase-ambientHC = 4.7°C/W (vertical)
Tambient
Pdissipation
PIN
POUT
h
T
case - Tambient
Pdissipation
Rthcase-ambient
=
Efficiency under given Operating Conditions
Thermal Impedance
POUTapp
h
Pdissipation = PIN - POUT
=
- POUTapp
Rthcase-ambient
Practical Example:
Take the RP100H-2405SRW with 9V input Voltage and 50% load. What is the maximum ambient operating temperature? Use converter vertical in application without
airflow.
Effmin = 91% @ Vnom
without Heat-sink
casemax - Tamb
with Heat-sink
casemax - Tamb
POUT = 100W
OUTapp = 100 x 0.5 = 50W
T
105-T
T
105-Tamb
4.95W
amb
Rth =
--> 6.7°C/W =
RthHC
=
--> 4.7°C/W =
P
Pdissipation
amb = 72°C
4.95W
Pdissipation
h = 91% (Efficiency vs. Load Graph)
T
TambHC = 82°C
50
0.91
Pdissipation
=
- 50 = 4.95W
Derating Graph(6)
(@ Chamber - tested with forced convection)
RP100H-2405SRW
RP100H-2405SRW-HC
100
80
60
40
20
0
100
80
60
40
20
0
0.5m/s
1m/s
1.5m/s
2m/s
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
2.5m/s
-40 -20
0
20 40
60 80 100 120
-40 -20
0
20 40
60 80 100 120
67
Ambient Temperature [°C]
Ambient Temperature [°C]
RP100H-4805SRW
RP100H-4805SRW-HC
100
80
60
40
20
0
100
80
60
40
20
0
0.5m/s
1m/s
1.5m/s
2m/s
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
2.5m/s
-40 -20
0
20 40
60 80 100 120
65
-40 -20
0
20 40
60
100 120
80
71
Ambient Temperature [°C]
Ambient Temperature [°C]
continued on next page
www.recom-power.com
REV.: 4/2020
PA-9
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-11005SRW
RP100H-11005SRW-HC
100
80
60
40
20
0
100
80
60
40
20
0
0.5m/s
1m/s
1.5m/s
2m/s
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
2.5m/s
-40 -20
0
20 40
60 80 100 120
-40 -20
0
20 40
60 80 100 120
50
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note6: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07,
2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
E196683
TW1608033-001, TW1608036-001,
TW1608037-001, TW1608079-001
IEC60950-1, 2nd Edition. 2005
EN60950-1, 2006
Information Technology Equipment - General Requirments for Safety
Railway Applications - Electrical Equipment used on rolling stock
16A081501E-C
RU-AT.49.09571
EN50155, 2007
TP TC 004/2011
RoHS 2011/65/EU
EAC
RoHS2+
EMI Compliance
Condition
Standard / Criterion
Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement
EN55032, Class A and Class B
with external components
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement
EN55011, Class A and Class B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity(7)
Air 8kV and Contact 6kV
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
20 V/m
2kV
Surge Immunity(7)
2kV
10 Vr.m.s
100A/m continuous; 1000A/m 1s
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Notes:
Note7: An external input filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The 24Vin and 48Vin version recommend 2pcs of aluminium elecrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KY series, 220µF/100V.
The 110Vin version recommend 2pcs of aluminium electrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KXJ series, 150µF/200V
continued on next page
www.recom-power.com
REV.: 4/2020
PA-10
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
EMI Filtering according to EN55032/11 Class A and EN50121-1 (24Vin and 48Vin)
C10
L1
Fuse
+V
IN
C1
C2
C3
C7
C8
C4
C5
C6
Case
-V
IN
C13
C9
C12
C11
Shield Plane
C8, C9, C10,
C11, C13
MODEL
C1, C2, C4
C3, C6, C7
C12
L1
470µF, 50V
4.7µF, 50V 1000pF, 3kV
3300pF, 3kV
1808 MLCC
156µH
CMC
RP100H-24xxSRW
RP100H-48xxSRW
Al cap. (lie down) Chemi-con KY 1812 MLCC 1808 MLCC
220µF, 100V 2.2µF, 100V 1000pF, 3kV
Al cap. (lie down) Chemi-con KY 1812 MLCC 1808 MLCC
1000pF, 3kV
1808 MLCC
224µH
CMC
RP100H-2405SRW
Conducted Emission EN55032 Class A
RP100H-4805SRW
Conducted Emission EN55032 Class A
continued on next page
REV.: 4/2020
www.recom-power.com
PA-11
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
EMI Filtering according to EN55032/11 Class A and EN50121-1 (110Vin)
C18
L1
Fuse
+V
IN
C1
C2
C5
C3
C4
C8
C9
C10
Case
-V
IN
C11
C12
C17
C20
C14
C16
C15
C13
C19
C7
C6
Shield Plane
C6, C11, C12, C13, C14,
C15, C16, C19, C20
1000pF, 5kV
MODEL
C1, C2, C8
C10
C17, C18
L1
100µF, 250V
Al cap. (lie down) Rubycon BXF 1812 MLCC
1µF, 250V
2200pF
TDK CD series Y1
1219µH
CMC
RP100H-110xxSRW
1808 MLCC
RP100H-11005SRW
Conducted Emission EN55032 Class A
continued on next page
REV.: 4/2020
www.recom-power.com
PA-12
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
EMI Filtering according to EN55032/11 Class B (24Vin and 48Vin)
C11
L1
L2
Fuse
+V
IN
C3
C4
C1
C2
C5
C6
C7 C8
Case
-V
IN
C9
C10
C13
C15
C12
C14
Shield Plane
C2, C4,
C5, C7, C8
MODEL
C1, C3, C6
C9, C10
C11
C12
C13, C14
C15
L1
470µF, 50V
4.7µF, 50V 10nF, 2kV 1000pF, 3kV 4700pF, 3kV 10nF, 2kV
156µH
CMC
RP100H-24xxSRW
RP100H-48xxSRW
N/A
Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC 1812 MLCC 1812 MLCC
220µF, 100V 2.2µF, 100V 10nF, 100V 2200pF, 3kV 4700pf, 3kV 10nF, 2kV 1000pF, 3kV
Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC 1812 MLCC 1812 MLCC 1808 MLCC
224µH
CMC
RP100H-2405SRW
Conducted Emission EN55032 Class B
RP100H-4805SRW
Conducted Emission EN55032 Class B
continued on next page
www.recom-power.com
REV.: 4/2020
PA-13
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
EMI Filtering according to EN55032/11 Class B (110Vin)
C15
L1
L2
Fuse
+V
IN
C1
C2
C5
C3
C7
C4
C6
C10 C11 C12
Case
-V
IN
C9
C14
C16
C18
C8
C13
C20
C22
C17
C21
C19
Shield Plane
C2 , C5,
C23, C24
C6, C7, C8, C9, C13, C14,
C17, C18, C19, C20, C21, C22
MODEL
C1, C3, C10
C4, C11, C12
C15, C16
L1
L2
1µF, 250V
1812 MLCC
1000pF, 5kV
1808 MLCC
RP100H-110xxSRW
N/A
150µF, 200V
Al cap. (lie down)
Chemi-con KY
C2, C4, C11,
C12
C8, C9, C13, C14, C17, C18 , C19,
C20, C21, C22, C23, C24
2200pF
TDK CD series Y1
1219µH
CMC
521µH
CMC
C5, C6, C7, C19
1µF/250V
1812 MLCC
100pF/250VAC
1808 MLCC
RP100H-11048SRW
N/A
RP100H-11005SRW
Conducted Emission EN55032 Class B
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
24Vin, 48Vin
110Vin
Metal
Plastic
case
24Vin, 48Vin
110Vin
FR4 PCB
Aluminium
Material
baseplate
potting
Silicone (UL94 V-0)
without Heat-sink
with Heat-sink
61.0 x 57.9 x 12.7mm
61.0 x 57.9 x 24.13mm
Dimensions (LxWxH)
Weight
without Heat-sink
with Heat-sink
105g
157g
continued on next page
REV.: 4/2020
www.recom-power.com
PA-14
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Dimension Drawing (mm)
24Vin, 48Vin
57.9
61.0
0.1
0.1
M3
Ø2.0
Ø1.0
4.8
4
3
5
6
7
8
Bottom View
Pin Connections
2
1
Pin #
Single
+Vin
9
1
2
3
4
5
6
7
8
9
CTRL
Case
4xM3
FC 48.26
-Vin
-Vout
-Sense
Trim
+Sense
+Vout
FC= Fixing Centers for Heat-sink
Pin Pitch Tolerance 0.25mm
Pin Dimension Tolerance 0.1mm
XX.X 0.5mm
57.9
61.0
110Vin
XX.XX 0.25mm
0.1
0.1
Ø2.0
M3
Ø1.0
4.8
4
3
5
6
7
8
Bottom View
2
1
9
4xM3
FC 48.26
continued on next page
REV.: 4/2020
www.recom-power.com
PA-15
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Dimension Drawing Heat-sink (mm)
57.9
48.26
Notes:
Note8: Max. tightening torque for Heat Sink: 0.34Nm
4xM3
0.1
0.1
Ø2.0
Ø1.0
PACKAGING INFORMATION
Parameter
Type
Value
without Heat-sink
with Heat-sink
157.0 x 88.0 x 23.0mm
157.0 x 88.0 x 35.0mm
Packaging Dimension
tray
Packaging Quantity
2pcs.
-55°C to +125°C
5% - 95% RH
Storage Temperature Range
Storage Humidity
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOMꢀs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2020
PA-16
相关型号:
©2020 ICPDF网 联系我们和版权申明