RP130440-5-24 [ETC]
;型号: | RP130440-5-24 |
厂家: | ETC |
描述: |
|
文件: | 总3页 (文件大小:86K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
Solid State Relays
PCB, 1-Phase ZS
Types RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24
•AC Solid State Relay for PCB mounting
•Zero switching
•Rated operational current: 3 or 5 AACrms
•Non-repetitive voltage: Up to 850 Vp
•Rated operational voltage: 240 V or 440 VACrms
•5 VDC logic compatible input
•12 and 24 VDC inputs for interfacing PLCs and
other controls
•Insulation: OPTO (input-output) 4000 VACrms
Product Description
Ordering Key
RP 130 240-5-12
The zero switching version Solid State Relay (PCB)
will work for resistive and in- Mounting type
The RP Solid State Relays
from Carlo Gavazzi feature a
very reliable design due to use
of optotechnology together
with high performance power
semiconductors.
ductive loads.
Switching mode
Rated operational voltage
With snubberless triacs as Rated operational current
output devices, dV/dt limiting Control voltage
RC-networks are no longer
required when switching in-
ductive loads.
Either 3 or 5 A relays are avail-
able for AC mains up to 400
VACrms.
Type Selection
Switching mode
Rated operational voltage
Rated operational current
Control voltage
130: Zero switching
240: 230 VACrms
440: 400 VACrms
3: 3 AACrms
5: 5 AACrms
05:
12:
24:
5 VDC
12 VDC
24 VDC
Selection Guide
Rated operational
voltage
Control voltage
Rated operational current
3 AACrms
5 AACrms
5 VDC
RP 130 240-3-05
RP 130 240-3-12
RP 130 240-3-24
RP 130 440-3-05
RP 130 440-3-12
RP 130 440-3-24
RP 130 240-5-05
RP 130 240-5-12
RP 130 240-5-24
RP 130 440-5-05
RP 130 440-5-12
RP 130 440-5-24
12 VDC
24 VDC
5 VDC
230 VACrms
400 VACrms
12 VDC
24 VDC
Specifications are subject to change without notice (30.06.1999)
1
RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24
General Specifications
RP 130 240-.-..
RP 130 440-.-..
Operational voltage range
Non-rep. peak voltage
Zero voltage turn-on
Operational frequency range
Power factor
24 to 280 VACrms
≥ 650 Vp
48 to 480 VACrms
≥ 850 Vp
≤ 30 V
≤ 50 V
45 to 65 Hz
≥ 0.5 @ 230 VACrms
UL, CSA, VDE
Yes
45 to 65 Hz
≥ 0.5 @ 400 VACrms
UL, CSA, VDE
Yes
Approvals
CE-marking
Input Specifications
RP 130 .40-.-05
RP 130 .40-.-12
RP 130 .40-.-24
Control voltage range
Control voltage
4 to 8 VDC
5 VDC
8 to 16 VDC
12 VDC
16 to 32 VDC
24 VDC
Pick-up voltage
≤ 4 VDC
≤ 8 VDC
≤ 16 VDC
≥ 1 VDC
Drop-out voltage
≥ 1 VDC
≥ 1 VDC
Input current @ rated voltage
Reverse voltage
≤ 10 mADC
≤ 6 VDC
≤ 10 mADC
≤ 6 VDC
≤ 10 mADC
≤ 6 VDC
Response time pick-up
Response time drop-out
≤ 1/2 cycle
≤ 1/2 cycle
≤ 1/2 cycle
≤ 1/2 cycle
≤ 1/2 cycle
≤ 1/2 cycle
Output Specifications
RP 130 .40-3-0
RP 130 .40-5-0
Rated operational current AC 1 3 Arms
AC 3 2.5 Arms
5 Arms
3 Arms
Minimum operational current
Rep. overload current t=1 s
20 mArms
20 mArms
≤ 12 Ap
90 Ap
≤ 6 Ap
Non-rep. surge current t=20 ms 60 Ap
Off-state leakage current
@ rated voltage and frequency ≤ 1 mArms
I2t for fusing t=1-10 ms
≤ 1 mArms
≤ 40 A2s
≤ 18 A2s
Critical dI/dt
≥ 20 A/ms
≥ 20 A/ms
On-state voltage drop
@ rated current
≤ 1.2 Vrms
≥ 100 V/µs
≤ 1.2 Vrms
≥ 100 V/µs
Critical dV/dt commutating
Critical dV/dt off-state≥ 100 V/µs ≥ 100 V/µs
Thermal Specifications
RP 13. .40-3-0
RP 13. .40-5-0
Operating temperature
Storage temperature
Junction temperature
Rth junction to case
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (≤ 257°F)
≤ 20.5 K/W
-20° to +70°C (-4° to +158°F)
-40° to +100°C (-40° to +212°F)
≤ 125°C (≤ 257°F)
≤ 15.6 K/W
Rth junction to ambient
≤ 33 K/W
≤ 21 K/W
2
Specifications are subject to change without notice (30.06.1999)
RP 130 ...-.-05, RP 130 ...-.-12, RP 130 ...-.-24
Insulation Input - Output
Derating Curve
Rated insulation voltage
Insulation resistance
Insulation capacitance
≥ 4000 VACrms
≥ 1010 Ω
Load current [A AC rms]
6
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
≤ 8 pF
5
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Reference voltage
according to VDE 0110 B
Insulation group C
4
3
2
1
0
500 VACrms, 600 VDC
0
10 20 30 40 50 60 70
Ambient temp. [°C]
Wiring Diagram
Functional Diagram
Mains input/
load output
2
+3
Control
input
Control
input
IC
Line/load
-4
1
Load output/
mains input
Housing Specifications
Dimensions
Weight
Approx. 10 g
11M
M = 1/10” = 2.54 mm
Housing material
Terminals
Noryl GFN 1, black
Copper, tin-plated
9M
4M
Potting compound
Flame-retardant polyurethane
3M
43 *
1
2
+3 4
*
= ± 0.2 mm
4 x ø1
** = ± 0.5 mm
Applications
Accessories
These relays can be used to vertically. If more than one Varistors
switch heaters, motors, lights, relay is mounted, please Fuses
valves or solenoids.
allow a minimum distance of For further information refer to “General Accessories”.
When used at full load current, 20 mm in between for suffi-
the relays must be placed cient air cooling.
Specifications are subject to change without notice (30.06.1999)
3
相关型号: