RP20-243.3SFR/XC-HC [ETC]
CONV DC/DC 20W 9-36VIN 3.3VOUT T;型号: | RP20-243.3SFR/XC-HC |
厂家: | ETC |
描述: | CONV DC/DC 20W 9-36VIN 3.3VOUT T |
文件: | 总9页 (文件大小:1415K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• Wide 4:1 input voltage range
• 2.25kVDC isolation
Features
DC/DC Converter
• Efficiency up to 89%
Regulated
Converter
• Six-sided continuous shield
• EN50155, UL/IEC/EN60950-1 certified
RP20-FR
20 Watt
2“ x 1“
Description
3
The RP20-FR series wide range input DC/DC converters are certified to UL60950-1 and cUL 60950-1.
This makes them ideal for all telecom and industrial applications where approved safety standards are
required. The 110VDC input versions have been especially designed for railway applications.
Single and Dual
Output
Selection Guide
Part Number
Input
Output
Output
Current
[mA]
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
[mA]
typ.
[%]
Load
[µF]
[VDC]
9-36
9-36
9-36
9-36
18-75
18-75
18-75
18-75
43-160
43-160
43-160
43-160
9-36
[VDC]
3.3
5
12
15
3.3
5
12
15
3.3
5
12
15
12
15
12
15
12
15
RP20-243.3SFR (2,3)
RP20-2405SFR (2,3)
RP20-2412SFR (2,3)
RP20-2415SFR (2,3)
RP20-483.3SFR (2,3)
RP20-4805SFR (2,3)
RP20-4812SFR (2,3)
RP20-4815SFR (2,3)
RP20-1103.3SFR (2,3)
RP20-11005SFR (2,3)
RP20-11012SFR (2,3)
RP20-11015SFR (2,3)
RP20-2412DFR (2,3)
RP20-2415DFR (2,3)
RP20-4812DFR (2,3)
RP20-4815FDFR (2,3)
RP20-11012DFR (2,3)
RP20-11015DFR (2,3)
4500
4000
1670
1330
4500
4000
1670
1330
4500
4000
1670
1330
833
728
947
938
945
364
473
469
467
159
209
207
206
947
937
473
468
207
204
85
88
89
88
85
88
89
89
85
87
88
88
88
89
88
89
88
89
7000
5000
850
700
7000
5000
850
RoHS2
+
REACH
compliant
compliant
10 from 10
E196683
700
7000
5000
850
700
500
350
500
350
500
EN50155 certified
9-36
667
833
667
833
UL60950-1 certified
IEC/EN60950-1 certified
EN55032 compliant
EN55024 compliant
EN50121-3-2 compliant
18-75
18-75
43-160
43-160
667
350
Notes:
Note1: Maximum values at nominal input voltage and full load
Model Numbering
RP20-__ __ _FR/_- _
(3)
nom. Input Voltage
“Package
”
(2)
nom. Output Voltage
“CTRL Logic
”
Single or Dual
Notes:
Note2: no suffix for CTRL function with positive logic (1=ON, 0=OFF)
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF)
or add suffix “XC” for omitted CTRL pin (refer to “Dimension Drawing (mm)”)
Note3:
add suffix “-HC” for premounted Heat-sink with clamps
Ordering Examples
RP20-2405SFR = 24V input, 5V output, single, positive Logic CTRL pin
RP20-4812DFR/N-HC = 48V input, 12V output, dual, negative Logic CTRL pin, Heat-sink premounted
RP20-11005SFR/XC = 110V input, 5V output, single, no CTRL pin
www.recom-power.com
REV.: 6/2020
PD-1
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
nom. Vin = 24VDC, nom. Vin = 48VDC
nom. Vin = 110VDC
Common Mode Choke
Pi-Type
Input Filter
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 110VDC
9VDC
18VDC
43VDC
24VDC
48VDC
110VDC
36VDC
75VDC
160VDC
50VDC
100VDC
170VDC
9VDC
Input Voltage Range
Input Surge Voltage
nom. Vin = 24VDC
100s max.
nom. Vin = 48VDC
nom. Vin = 110VDC
DC-DC ON
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 110VDC
DC-DC OFF
8VDC
16VDC
40VDC
DC-DC ON
DC-DC OFF
18VDC
43VDC
+10%
Under Voltage Lockout (UVLO)
DC-DC ON
DC-DC OFF
Output Voltage Trimming
refer to “OUTPUT VOLTAGE TRIMMING”
-10%
Input Reflected Ripple Current
30mAp-p
Power up
ON/OFF CTRL
30ms
30ms
Start-up Time
V
Open or 3.0VDC < CTRL< 15VDC
DC-DC ON
DC-DC OFF
Positive Logic
Negative Logic
V
Short or 0VDC < CTRL< 1.2VDC
ON/OFF CTRL (4)
V
Short or 0VDC < CTRL< 1.2VDC
DC-DC ON
DC-DC OFF
V
Open or 3.0VDC < CTRL< 15VDC
DC-DC ON
DC-DC OFF
-0.5mA
297kHz
+1.0mA
2.5mA
Input Current of CTRL pin
Standby Current
Internal Operating Frequency
330kHz
363kHz
measured at 20MHz BW
with a 1µF/50V X7R MLCC
3.3Vout, 5Vout
12Vout, 15Vout
75mVp-p
100mVp-p
Ripple and Noise
Notes:
Note4: If suffix “XC” is specified, pin6 will be absent. If fitted, the ON/OFF control function can be
positive or negative logic. The pin voltage is referenced to -Vin pin
RP20-2405SFR
Efficiency vs. Input Voltage full load
Efficiency vs. Output Current
95
90
85
80
75
70
65
60
55
95
90
85
80
75
70
65
60
9Vin
24Vin
36Vin
50
10
9
12
15
18
21
24
27
30
33
36
20
30
40
50
60
70
80
90
100
Input Voltage [VDC]
Output Current [%]
continued on next page
REV.: 6/2020
www.recom-power.com
PD-2
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
RP20-4805SFR
Efficiency vs. Output Current
Efficiency vs. Input Voltage full load
95
95
90
90
85
80
75
70
65
85
80
75
70
65
60
55
50
18Vin
48Vin
75Vin
60
10
20
30
40
50
60
70
80
90
100
18
24
30
36
42
48
54
60
66
72
75
Output Current [%]
Input Voltage [VDC]
RP20-11005SFR
Efficiency vs. Output Current
Efficiency vs. Input Voltage full load
95
90
95
90
85
80
75
85
80
75
70
65
60
70
65
60
43Vin
110Vin
160Vin
55
50
10
43 52 62 72 84 96 110 125 136 143 160
20
30
40
50
60
70
80
90
100
Input Voltage [VDC]
Output Current [%]
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for choosing these
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
Trim up
Trim down
-Vout
Trim
Trim
R
R
D
U
+Vout
continued on next page
REV.: 6/2020
www.recom-power.com
PD-3
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
RP20-xx3.3SFR
[%]
[VDC]
[kW]
Trim up
Vout =
RU =
1
2
3
4
5
6
7
8
9
10
3.333
385.07
3.366
191.51
3.399
126.99
3.432
94.73
3.465
75.37
3.498
62.47
3.531
53.25
3.564
46.34
3.597
40.96
3.63
36.66
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
3.267
116.72
3.234
54.78
3.201
34.13
3.168
23.81
3.135
17.62
3.102
13.49
3.069
10.54
3.036
8.33
3.003
6.60
2.97
5.23
RP20-xx05SFR
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
5.05
5.10
5.15
83.18
5.20
61.83
5.25
49.05
5.30
40.53
5.35
34.45
5.4
5.45
26.34
5.50
23.50
253.45
125.70
29.89
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
4.95
4.90
4.85
78.01
4.80
56.72
4.75
43.94
4.70
35.42
4.65
29.34
4.60
24.78
4.55
21.23
4.50
18.39
248.34
120.59
RP20-xx12SFR
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
12.12
12.24
99.06
12.36
64.33
12.48
46.97
12.60
36.56
12.72
29.61
12.84
24.65
12.96
20.93
13.08
18.04
13.20
15.72
203.22
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
11.88
776.56
11.76
380.72
11.64
248.78
11.52
182.81
11.40
143.22
11.28
116.83
11.16
97.99
11.04
83.84
10.92
72.85
10.8
64.06
RP20-xx15SFR
[%]
[VDC]
[kW]
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
RU =
15.15
15.3
78.22
15.45
50.45
15.60
36.56
15.75
28.22
15.90
22.67
16.05
18.70
16.20
15.72
16.35
13.41
16.50
11.56
161.56
[%]
[VDC]
[kW]
Trim down
Vout =
RD =
1
2
3
4
5
6
7
8
9
10
14.85
818.22
14.70
401.56
14.55
262.67
14.40
193.22
14.25
151.56
14.10
123.78
13.95
103.94
13.80
89.06
13.65
77.48
13.50
68.22
REGULATIONS
Parameter
Condition
Value
Output Accuracy
1.0%
low line to high line,
full load
Single
Dual
0.2%
0.5%
Line Regulation
Single
Dual
0.2%
1.0%
0% to 100% load
10% to 90% load
Load Regulation
Cross Regulation
Single
Dual
0.1%
0.8%
asymmetrical 25%<>100% load
25% load step change
5.0%
Transient Response Recovery Time
250µs typ.
www.recom-power.com
REV.: 6/2020
PD-4
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
3.3Vout
5Vout
12Vout
15Vout
3.7VDC - 5.4VDC
5.6VDC - 7.0VDC
13.5VDC - 19.6VDC
16.8VDC - 20.5VDC
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
Isolation Voltage(5)
% Iout rated
150% typ.
I/P to O/P
I/P to O/P to case
2.25kVDC/1minute
1.6kVDC/1minute
Isolation Resistance
Isolation Capacitance
Notes:
Viso= 500VDC
1GW min.
3000pF max.
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Condition
Value
without derating
with derating
-40°C to +79°C
-40°C to +101°C
Operating Temperature Range
Maximum Case Temperature
Temperature Coefficient
+105°C
0.02%/ꢀ max.
without heat-sink
with heat-sink
12ꢀ/W
10ꢀ/W
Thermal Impedance
Operating Humidity
@ natural convection 0.1m/s
non-condensing
5% - 95% RH
Environmental testing Part 2-1: Tests
Test A: Cold
Temperature: -40°C
Dwell Time: 2 hours
according to EN60068-2-1:2007
Environmental testing Part 2-2: Tests
Test B: Dry heat
Temperature: +85°C
Dwell Time: 6 hours
according to EN60068-2-2:2007
according to EN60068-2-30:2005
Temperature: +25 to +55°C
Humidity: 90% to 100%RH
Test Duration: 24 hours/cycle, 2 cycles, total 48 hours
Random vibration test 5Hz to 150Hz, Z-Axis
1.01m/s² (0.103Grms), Y-Axis, X-Axis 0.70m/s²
(0.0714Grms), Duration 10min/Axis
Environmental testing Part 2-30: Tests
Test Db: Damp heat, cyclic (12 h + 12 h cycle)
Railway applications – Rolling stock equipment –
Shock and vibration tests
according to EN61373:2010
according to EN45545-2:2013
according to EN ISO 4589-2 OI
Fire protection on railway vehicles
Fire hazard testing Part 2-11: Glowing/hot-wire
based test methods – Glow-wire flammability test
method for end-products
Oxygen index test
Glow-wire test
Fire hazard testing Part 11-10: Test flames – 50 W
horizontal and vertical flame test methods
according to EN60695-2-11
Shock
according to MIL-STD-810F
according to MIL-STD-810F
according to MIL-STD-810F
1523 x 103 hours
Thermal Shock
Vibration
MTBF
according to MIL-HDBꢀ-217F, G.B.
continued on next page
REV.: 6/2020
www.recom-power.com
PD-5
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
Derating Graph (7)
RP20-2415SFR
RP20-2415SFR-HC
100
100
80
60
40
20
0
80
60
40
20
0
-40 -20
0
20 40
60 80 100 120
-40 -20
0
20 40
60 80 100 120
Ambient Temperature7[9°C] 101
Ambient Temperature [°C]101
85
Notes:
Note7: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Standard
UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
E196683
Information Technology Equipment, General Requirements for Safety
(LVD)
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
TW1708011-001
Railway Applications - Electrical Equipment used on rolling stock
15A100702E-C
RU-AT.49.09571
EN50155:2007
TP TC 004/2011
EAC
RoHS2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance (Railway)
Condition
Standard / Criterion
Railway Applications - Electromagnetic Compatibility
EN50121-3-2:2006
Air 2, 4, 8kV
Contact 2, 4, 6kV
20V/m (80-1000MHz)
10V/m (1400-2100MHz)
5V/m (2100-2500MHz)
ESD Electrostatic Discharge Immunity Test
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
Radiated, Radio-Frequency, Electromagnetic Field Immunity Test
Fast Transient and Burst Immunity (8)
DC Power Port: 2kV
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
DC Power Port: L-L 0.5, 1kV
DC Power Port: L-E 0.5, 1, 2kV
Surge Immunity (8)
Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
DC Power Port: 10V
continued on next page
REV.: 6/2020
www.recom-power.com
PD-6
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
EMC Compliance (Multimedia)
Condition
Standard / Criterion
Industrial, scientific and medical equipment - Radio frequency
disturbance characteristics - Limits and methods of measurement
without external filter
without external filter
EN55011, Class A
EN55011, Class B
Electromagnetic compatibility of multimedia equipment - Emission
requirements (24Vin and 48Vin)
without external filter
without external filter
EN55032, Class A
EN55032, Class B
Electromagnetic compatibility of multimedia equipment - Emission
requirements (110Vin)
without external filter
with external filter
EN55032, Class A
EN55032, Class B
Information Technology Equipment - Immunity Characteristics - Limits
and Methods of Measurement
EN55024:2010 + A1:2015
Air 2, 4, 8kV
Contact 2, 4, 6kV
ESD Electrostatic Discharge Immunity Test
IEC61000-4-2:2008, Criteria A
Radiated, Radio-Frequency, Electromagnetic Field Immunity Test
Fast Transient and Burst Immunity
20V/m (80-1000MHz)
DC Power Port: 2kV
DC Power Port: 0.5, 1, 2kV
DC Power Port: 10V
IEC61000-4-3:2006 + A2:2010, Criteria A
IEC61000-4-4:2012, Criteria A
IEC61000-4-5:2014, Criteria A
IEC61000-4-6:2013, Criteria A
IEC61000-4-8:2009, Criteria A
Surge Immunity
Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
Power Magnetic Field Immunity
50Hz 1A/m
Notes:
Note8: An external input filter capacitor is required if the module has to meet EN61000-4-4, -5
The filter Recom suggests: 24VDC and 48VDC input. Nippon chemi-con ꢀY series, 220µF/100V
110VDC input: Rubycon BXF series, 100µF/250V
EMI Filtering according to EN55032 Class B (110Vin Single)
L1
F1
+Vin
+Vout
+Vin
-Vin
+Vout
C1 C2 C3 C4
-Vout
-Vin
-Vout
C5
EMI Filtering according to EN55032 Class B (110Vin Dual)
L1
F1
+Vout
Com
-Vout
+Vin
+Vin
-Vin
+Vout
C1 C2 C3 C4
Com
-Vout
-Vin
C5
Component List
MODEL
C1
C2/C3/C4
C5
L1
39µF/250V
Al Cap. (lie down)
Rubycon BX
RP20-110xxSFR
RP20-110xxDFR
0.47µF/250V
1812 MLCC
1000pF/3kV
1808 MLCC
CMC: 470µH
ref.: WE-SL5 744272471
www.recom-power.com
REV.: 6/2020
PD-7
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
case
base
Value
nickel coated copper
FR4 PCB
Material
potting
silicone (UL94 V-0)
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
without Heat-sink
with Heat-sink
Dimensions (LxWxH)
Weight
without Heat-sink
with Heat-sink
30g
40.89g
Dimension Drawing (mm)
Pinning Information
Pin #
Single
+Vin
Dual
+Vin
1
2
3
4
5
6
-Vin
-Vin
+Vout
Trim (4)
-Vout
CTRL(2)
+Vout
Com
50.8
25.4
-Vout
CTRL(2)
Tolerance: xx.x= ±±.ꢀ55
xx.xx= ±±.ꢁꢀ55
0.1
8 x 2.54= 20.32
15.20
Ø 1.0
Recommended Footprint Details
2.54
6
5
4
3
3
4
5
2
1
1 Bottom Vieꢁ
ꢀop Vieꢁ
2
6
Dimension Drawing with Heat-sink (mm)
50.8
Top View
Heat-sink
56.8
24.2
0.1
8 x 2.54= 20.32
15.20
Ø 1.0
www.recom-power.com
REV.: 6/2020
PD-8
RP20-FR
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Series
PACKAGING INFORMATION
Parameter
Type
Value
tube
tray
without heat-sink
with heat-sink
255.0 x 55.0 x 22.0mm
302.5 x 222.0 x 20.0mm
Packaging Dimension (LxWxH)
tube
tray
without heat-sink
with heat-sink
9pcs
20pcs
Packaging Quantity
Storage Temperature Range
Storage Humidity
-55°C to +125°C
5% - 95% RH
non-condensing
The product information and specifications may be subꢀect to changes even without prior written notice.The product has been designed for various applicationsꢁ its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOMꢂs explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 6/2020
PD-9
相关型号:
©2020 ICPDF网 联系我们和版权申明