RSO-4805S/H2 [ETC]
CONV DC/DC 1W 36-72VIN 05VOUT;型号: | RSO-4805S/H2 |
厂家: | ETC |
描述: | CONV DC/DC 1W 36-72VIN 05VOUT |
文件: | 总5页 (文件大小:723K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• 2:1 and 4:1 Wide input voltage range
• SIP8 Package style
Features
DC/DC Converter
• UL94V-0 Package material
• Continuous short circuit protected
• Low noise
Regulated
Converters
• 1kVDC, 2kVDC or 3kVDC Isolation
RSO-S(D)(Z)
Description
1 Watt
SIP8
Single & Dual
Output
High-power-density, an industrial temperature range of -40°C to +100°C and extra features like
On-Off-control are just some of the characteristics of this converter, ideal for highly sophisticated
industrial-designs. The RSO series is available with isolation of 2kV or 3kV by choosing option „/H2“ or
„/H3“. The standard version offers 2:1 input voltage range, while the “Z” version features 4:1 input
voltage range, which includes an input voltage range covering both 5V and 12V supplies.
Selection Guide
Part
Number
Input
Voltage Range
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency max. Capacitive
typ.
[%]
Load (3)
[µF]
RSO-xx3.3S
RSO-xx3.3SZ
RSO-xx05S
RSO-xx05SZ
RSO-xx09S
RSO-xx09SZ
RSO-xx12S
RSO-xx12SZ
RSO-xx15S
RSO-xx15SZ
RSO-xx3.3D
RSO-xx3.3DZ
RSO-xx05D
RSO-xx05DZ
RSO-xx09D
RSO-xx09DZ
RSO-xx12D
RSO-xx12DZ
RSO-xx15D
RSO-xx15DZ
4.5-9 (1), 9-18, 18-36, 36-72
9-36, 18-72
68-72
68-70
3.3
5
300
200
111
83
3300
1200
680
4.5-9 (1), 9-18, 18-36, 36-72
4.5-18(1,2), 9-36, 18-72
4.5-9 (1), 9-18, 18-36, 36-72
4.5-18 (1,2), 9-36, 18-72
4.5-9 (1), 9-18, 18-36, 36-72
4.5-18 (1,2), 9-36, 18-72
4.5-9 (1), 9-18, 18-36, 36-72
4.5-18 (1,2), 9-36, 18-72
4.5-9 (1), 9-18, 18-36, 36-72
9-36, 18-72
4.5-9 (1), 9-18, 18-36, 36-72
4.5-18 (1,2), 9-36, 18-72
4.5-9 (1), 9-18, 18-36, 36-72
4.5-18 (1,2), 9-36, 18-72
4.5-9 (1) 9-18, 18-36, 36-72
4.5-18 (1,2), 9-36, 18-72
4.5-9 (1), 9-18, 18-36, 36-72
4.5-18 (1,2), 9-36, 18-72
73-78
74-81
75-78
75-83
77-83
75-83
78-83
68-72
70-74
73-76
77
9
12
15
3.3
5
680
67
680
150
100
56
1500
470
E224736
UL60950-1 certified
CAN/CSA No. 60950-1-07 certified
IEC/EN60950-1 certified
IEC/EN60601-1 certified
CB Report
74-78
74-78
75-80
75-80
75-80
75-80
9
470
12
15
42
330
34
330
Notes:
Note1: Derate to 75% if VIN is <5VDC (refer to „Line Derating“ graph on page 2)
Note2: 12V 4:1 input also requires an external 10µF capacitor (refer to „Protection Circuit“ on page 3)
Note3: Maximum capacitive load is defined as the capacitive load that will allow start up in under 1 second
without damage the converter
Model Numbering
RSO- __ __ _ _ /__
nom. Input Voltage
Output Voltage
Single or Dual
Isolation (5)
2:1 or 4:1 Input (4)
Notes:
Note4: add „Z“ for 4:1 Input Voltage (12= 4.5-18VDC; 24= 9-36VDC; 48= 18-72VDC)
Note5: add suffix „/H2“ for 2kVDC isolation or „/H3“ for 3kVDC isolation, without = standard 1kVDC isolation
Ordering Examples:
RSO-0512S:
4.5-9Vin
4.5-9Vin
4.5-18Vin
12Vout
5Vout
12Vout
Single
Dual
Single
2:1 Input Voltage
4:1 Input Voltage
4:1 Input Voltage
1kVDC Isolation
3kVDC Isolation
2kVDC Isolation
RSO-0505DZ/H3
RSO-1212SZ/H2
www.recom-power.com
REV.: 3/2019
ECO-1
RSO-S(D)(Z)
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
4.5VDC (1)
9VDC
18VDC
36VDC
4.5VDC (1,2)
9VDC
18VDC
Typ.
Max.
5VDC
9VDC
18VDC
36VDC
72VDC
12VDC
24VDC
48VDC
2:1 Input
4:1 Input
nom Vin=
Input Voltage Range
12VDC
18VDC
36VDC
72VDC
nom Vin= 24VDC
48VDC
40mA
32mA
25mA
15mA
5VDC
12VDC
24VDC
48VDC
Quiescent Current
nom Vin=
Minimum Load (6)
ON/OFF CTRL
10%
open or high impedance
DC-DC ON
external VCTRL= 5-12VDC + 1N4148 and 68W resistor
DC-DC OFF
DC-DC ON
DC-DC OFF
3mA
6mA
Input Current of CTRL Pin
Standby Current
10mA
200kHz
100kHz
500kHz
800kHz
2:1 Input
4:1 Input
Internal Operating Frequency
Output Ripple and Noise
20MHz BW
50mVp-p
Notes:
Note6: Operation below 10% load won‘t harm the converter, but specifications may not be met
Efficiency vs. Load
Line Derating
RSO-24xx
100
90
80
70
60
50
40
30
20
10
0
100
90
80
75
70
60
50
40
30
5Vout
9Vout
12Vout
15Vout
20
10
0
0
10 20 30 40 50 60 70 80 90 100
4.5 5.0
Output Load [%]
Input Voltage [VDC]
ON/OFF CTRL
+Vin
+Vout
+Vin
+Vout
68Ω
1N4148
DC-DC ON: Open or high impedance
DC-DC OFF: VCTRL= 5-12VDC + 1N4148 and 68W resistor
CTRL
-Vin
VCTRL
-Vin
-Vout
-Vout
continued on next page
REV.: 3/2019
www.recom-power.com
ECO-2
RSO-S(D)(Z)
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
+Vin
+Vout
+Vin
VCTRL
-Vin
+Vout
VCTRL
DC-DC ON
DC-DC OFF
ꢀꢁꢂΩ
ꢃꢀ
0
-Vin
-Vout
-Vout
REGULATIONS
Parameter
Condition
Value
Output Accuracy
2.0% typ.
2:1 Input
4:1 Input
0.2% max.
0.5% max.
Line Regulation
Load Regulation
2:1 Input
4:1 Input
0.4% max.
0.5% typ.
10% to 100% full load
PROTECTIONS
Parameter
Type
below 100mW
Value
continuous, auto recovery
1kVDC
Short Circuit Protection (SCP)
tested for 1 second
rated for 1 minute
tested for 1 second
rated for 1 minute
tested for 1 second
rated for 1 minute
standard without suffix
/H2 version
500VAC/60Hz
2kVDC
Isolation Voltage (7)
1kVAC/60Hz
3kVDC
/H3 version
1.5kVAC/60Hz
1GW min.
Isolation Resistance
Isolation Capacitance
2:1 Input
Single
Dual
Single
10pF min. / 40pF typ. / 60pF max.
120pF min. / 170pF typ. / 250pF max.
200pF max.
standard without suffix
/H2 and /H3 version
2:1 Input
4:1 Input
2:1 Input
4:1 Input
Single/Dual
Single/Dual
5pF min. / 30pF typ. / 60pF max.
30pF max.
basic (IEC/EN60950-1)
functional (IEC/EN6060-1)
Insulation Grade
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Protection Circuit
Fꢀ
+Vin
+Vout
+Vin
+Vout
Cꢀ
RSO-12xxSZ(DZ) requires a 10µF MLCC capacitor (C1) on input side
-Vin
-Vout
-Vin
-Vout
ENVIRONMENTAL
Parameter
Operating Temperature Range
Operating Altitude
Condition
Value
-40°C to +100°C
5000m
with derating @ free air convection (see graph)
continued on next page
REV.: 3/2019
www.recom-power.com
ECO-3
RSO-S(D)(Z)
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Parameter
Operating Humidity
Pollution Degree
Condition
non-condensing
Value
95% RH max.
PD2
+25°C
+85°C
1685 x 103 hours
254 x 103 hours
MTBF
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ Chamber and free air convection)
100
90
80
70
60
50
40
30
20
10
0
4:1 Input Volatge
2:1 Input Voltage
-40
-20
0
20
40
60
80
100
120
75 85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
SPCLVD1605077-10
L0339L48-CB-1-B1
E224736-A34-UL
Standard
IEC60950-1, 2nd Edition, AM2: 2013
EN60950-1, 2nd Edition, A2:2013
Information Technology Equipment, General Requirements for Safety (LVD)
Information Technology Equipment, General Requirements for Safety (CB)
Information Technology Equipment, General Requirements for Safety
IEC60950-1:2005, 2nd Edition + A2:2013
UL60950-1, 2nd Edition, 2014
CAN/CSA C22.2 No. 60950-1-07
IEC60601-1:2005 + C2:2007 + A1:2012, 3rd Edition
EN60601-1:2006 + A1:2013 + A12:2014
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
WD-SE-R-180675-A0
RU-AT.AB49.B.09571
EAC
TP TC 004/2011
RoHS2
RoHS 2011/65/EU + AM2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment - Emission
requirements
with external filter
(see filter suggestion below)
EN55032, Class A
EN55032, Class B
(9)
EMC Filtering Suggestions according to EN55032
Component List Class A
Lꢀ
Model
C1
C2
L1
+Vin
+Vout
+Vin
-Vin
+Vout
RSO-0505S
RSO-1205S
RSO-2405S
RSO-4805S
Cꢀ
3.9µH choke
RLS-397
10µF/100V
MLCC
N/A
-Vin
-Vout
-Vout
Cꢁ
Component List Class B
Model
C1
C2
L1
Notes:
RSO-0505S
RSO-1205S
RSO-2405S
RSO-4805S
Note9: Filter suggestions are valid for indicated part numbers only.
For other part numbers, please contact RECOM tech support for advice.
5.6µH choke
RLS-567
10µF/100V
MLCC
2.2nF
12µH choke RLS-126
www.recom-power.com
REV.: 3/2019
ECO-4
RSO-S(D)(Z)
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
potting
PCB
Value
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
Material
FR4, (UL94 V-0)
Dimension (LxWxH)
Weight
21.8 x 11.1 x 9.2mm
4.7g typ.
Dimension Drawing (mm)
embossed logo
Pinning information
21.8
9.2
Pin #
Single
Dual
-Vin
+Vin
CTRL (10)
NC
+Vout
COM
-Vout
1
2
3
5
6
7
8
-Vin
+Vin
CTRL (10)
NC
+Vout
-Vout
NC(11)
Marking
0.51+0.10/-0.05
0.25
0.05
Recommended Footprint Details
1.00 Ø +0.15/-0
NC= no connection
Tolerance: xx.x= 0.5ꢀꢀ
xx.xx= 0.25ꢀꢀ
Bottom View
1 2 3
5 6 7 8
1 2 3
5 6 7 8
Top View
2.00
7x2.54= 17.78
2.54
Notes:
Note10: This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when
the pin is open the converter is ON. There is no allowed low state for this pin. (refer to „ON/OFF CTRL“ on page 2)
Note11: This pin is used internally. No external connection allowed
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
tube
tube
Value
520.0 x 17.0 x 10.0mm
22pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 3/2019
ECO-5