RU2S-C [ETC]

RU Series - General Purpose Relays;
RU2S-C
型号: RU2S-C
厂家: ETC    ETC
描述:

RU Series - General Purpose Relays

文件: 总4页 (文件大小:143K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
RU Series  
Relays  
RU Series — General Purpose Relays  
Key features of the RU series include:  
• Non-polarized LED indicator standard  
• Solder-free construction (spot welded, no solder points, lead-free)  
• No internal wires  
• Mechanical flag indicator standard  
• Manual latching lever with color coding for AC or DC coil  
• Available without latching lever (or with momentary check button)  
• Snap-on marking plate standard  
• Cadmium-free contacts - RoHS compliant  
• Color coded coils for visual distinction  
• Contact rating 6A: 4PDT  
10A: DPDT  
RU2  
RU4  
E
UL Recognized  
File No. E66043, Vol 8, sec. 1  
AgSnOIn (silver tin oxide  
indium)  
AuAg/Ag (gold-silver alloy  
on silver)  
Contact Material  
Vol 8, sec. 2  
50 mmaximum  
Contact Resistance  
Minimum  
Applicable Load  
24VDC, 5mA  
(reference value)  
1V DC, 1mA (standard)  
1V DC, 0.1mA (bifurcated)  
B020813332451  
20 msec maximum  
Operating Time  
Release Time  
Maximum  
Continuous Applied  
Voltage  
(AC/DC) at 20°C  
20 msec maximum  
110%  
CSA Certified  
File No. LR35144-135844  
Minimum  
Operating Voltage  
(AC/DC) at 20°C  
Drop-Out Voltage  
(AC) at 20°C  
80%  
30%  
Drop-Out Voltage  
(DC) at 20°C  
Power Consumption  
10%  
Ordering Information  
1.1-1.4VA (AC); 0.9-1.0W (DC)  
Between contact and coil:  
Between contact and coil:  
2,500VAC, 1 minute  
Between poles:  
2,500VAC, 1 minute  
Between poles:  
Consult factory for other voltages.  
2,500VAC, 1 minute  
Between contacts of the  
same pole:  
2,000VAC, 1 minute  
Between contacts of the  
same pole:  
Dielectric Strength  
Basic Part No.  
Coil Voltage:  
RU 4  
S – ( ) – D12  
1,000VAC, 1 minute  
1,000VAC, 1 minute  
1,800 operations/hr  
Frequency Response  
Vibration Resistance  
# of Contacts  
2 = DPDT  
4 = 4PDT  
42 = 4PDT bifurcated  
contacts  
Operating extremes:  
10 to 55Hz,  
Amplitude 1.0 mm p-p  
Damage limits: 10 to 55Hz,  
Amplitude 1.0 mm p-p  
Coil Voltage Code**  
D12 = 12V DC  
D24 = 24V DC  
D110 = 110V DC  
A24 = 24V AC  
Operating extremes:  
2
150 m/s (15G)  
Shock Resistance  
Life Expectancy  
Damage limits:  
Option*  
(Blank) = with latching check  
button  
C = without check button  
M = momentary check button  
D = surge suppression diode (DC coils only)  
A110 = 110-120V AC  
A220 = 220-240V AC  
2
1,000 m/s (100G)  
Mechanical:  
AC: 20,000,000 operations  
minimum  
DC: 30,000,000 operations  
minimum  
Electrical:  
see electrical life curve  
1. *All come with bi-polar LED, mechanical flag indica-  
tor, marking plate.  
2. **Contact IDEC for other voltages.  
IP40  
-55 to +70°C (no freezing)  
35g  
Degree of Protection  
Operating Temperature  
Weight  
E-8  
www.idec.com  
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC  
Relays  
RU Series  
Part Numbers  
Part Numbers: RU Series with Options  
Contact  
Termination  
Without  
With Momentary  
Standard  
With Diode*  
Latching Lever Check Button  
Configuration  
DPDT  
RU2S  
RU4S  
RU42S  
RU2S-C  
RU4S-C  
RU42S-C  
RU2S-M  
RU4S-M  
RU42S-M  
RU2S-D  
RU4S-D  
RU42S-D  
Standard  
*DC coils only.  
S: Solder/plugin  
4PDT  
4PDT  
Bifurcated  
Part Numbers: Sockets  
Springs & Clips (optional)  
Part Number Use With  
Spring Clamp  
Relays  
Standard DIN Finger-Safe DIN  
Panel Mount PC Mount  
DIN Rail Mount Rail Mount  
Rail Mount  
SFA-101  
SFA-202  
SY4S-02F1①  
use with SY4S-05, -05C  
SM2S-05, -05C  
RU2S  
RU4S  
SU2S-11L  
SU4S-11L  
SM2S-05  
SY4S-05  
SM2S-05C  
SU4S-11L, SU2S-11L  
SY4S-61  
SY4S-51  
SY4S-62  
SFA-301①  
SFA-302①  
SY4S-51F1①  
SY4S-05C  
use with SY4S-51, -61  
E
Top latch  
Side latch  
See Section F for details on sockets. All DIN rail mount  
sockets shown above can be mounted using DIN rail BNDN1000.  
Pullover spring  
Part Numbers: Marking Strip  
Marking Strip Color Code  
Color Code Color Code  
Item  
Part Number Quantity  
RU Marking Strip  
RU9Z-PPN10, 10 pieces per package  
Yellow*  
Y
Blue  
S
*yellow marking  
strip standard on  
all RU relays.  
Green  
Amber  
G
A
White  
W
In place of , insert color code  
from chart at right.  
Ratings  
Coil Ratings  
Rated Voltage Voltage Code  
Inductance  
Energizing De-Energizing  
Coil Tape Rated Current 1ꢀ5  
Coil Resistance  
105 at 20°C  
Inrush  
Current  
Colors  
at 20°C  
white  
37.5mA  
8.4mA  
4.2mA  
83.3mA  
41.7mA  
9.1mA  
164 Ω  
4,550 Ω  
18,230Ω  
160 Ω  
60mA  
14mA  
7mA  
1.8H  
36H  
0.96H  
22H  
24V  
A24  
dark blue  
red  
AC 110-120V A110  
220-240V A220  
144H  
87H  
yellow*  
green  
12V  
DC 24V  
110V  
D12  
605 Ω  
N/A  
D24  
yellow*  
12, 100 Ω  
D110  
*Voltage printed in black.  
Contact Ratings (Standard)  
Contact Ratings (Bifurcated)  
Voltage  
Resistive Inductive  
Voltage  
Resistive Inductive  
DPDT  
4PDT  
DPDT  
4PDT  
DPDT  
4PDT  
DPDT  
4PDT  
10A  
6A  
5A  
30V DC  
4PDT  
4PDT  
4PDT  
4PDT  
3A  
1.5A  
30V DC  
3A  
110V DC  
120V DC  
250V DC  
0.6A  
0.4A  
10A  
6A  
0.3A  
0.2A  
5A  
3A  
3A  
0.8A  
0.8A  
110V DC  
120V AC  
240V AC  
3A  
10A  
6A  
5A  
3A  
www.idec.com  
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC  
E-9  
RU Series  
Relays  
Internal Circuit*  
RU2S Standard  
RU2S-D with Diode  
RU4S/RU42S Standard  
RU4S-D/RU42S-D with Diode  
(1)12  
(4)42  
(1)12  
(4)42  
(1)12 (2)22 (3)32 (4)42  
(1)12 (2)22 (3)32 (4)42  
(5)14  
(9)11  
(8)44  
(5)14  
(9)11  
(8)44  
(5)14 (6)24 (7)34 (8)44  
(9)11 (10)21 (11)31 (12)41  
(5)14 (6)24 (7)34 (8)44  
(9)11 (10)21 (11)31 (12)41  
(12)41  
(12)41  
(14)A2  
(13)A1  
(14)A2  
(14)A2  
(13)A1  
(14)A2  
(13)A1  
(13)A1  
Over 24V DC  
Over 24V DC  
Over 24V AC/DC  
Over 24V AC/DC  
(1)12  
(4)42  
(1)12  
(4)42  
(1)12 (2)22 (3)32 (4)42  
(1)12 (2)22 (3)32 (4)42  
(5)14  
(9)11  
(8)44  
(5)14  
(9)11  
(8)44  
(5)14 (6)24 (7)34 (8)44  
(9)11 (10)21 (11)31 (12)41  
(5)14 (6)24 (7)34 (8)44  
(9)11 (10)21 (11)31 (12)41  
(12)41  
(12)41  
(14)A2  
(13)A1  
(14)A2  
(14)A2  
(13)A1  
(14)A2  
(13)A1  
(13)A1  
24V DC or less  
24V DC or less  
24V AC/DC or less  
24V AC/DC or less  
Numbers not in parenthesis follow international system  
of labeling terminals.  
Image as viewed from bottom of relay. Refer to socket for exact  
wiring layout (Section F).  
E
Electrical Life Curves  
RU2 (Resistive Load)  
RU4 (Resistive Load)  
RU42 (Resistive Load)  
AC250V  
DC30V  
DC110V  
AC250V  
DC30V  
DC110V  
AC250V  
DC30V  
DC110V  
1000  
500  
1000  
500  
500  
100  
50  
100  
50  
100  
50  
10  
1
10  
1
10  
1
0.02  
0.1  
0.5 1  
3 6  
0.1  
0.5 1  
3 6  
0.1  
0.5 1  
5 10  
Load Current (A)  
Load Current (A)  
Load Current (A)  
RU2 (Inductive Load)  
RU4 (Inductive Load)  
RU42 (Inductive Load)  
AC250V  
DC30V  
DC110V  
AC250V DC30V  
DC110V  
AC250V  
DC30V  
DC110V  
1000  
500  
1000  
500  
500  
100  
50  
100  
50  
100  
50  
10  
1
10  
1
10  
1
AC COS =0.3  
DC L/R=7ms  
AC COS =0.3  
DC L/R=7ms  
AC COS =0.3  
DC L/R=7ms  
0.02  
0.1  
0.5 1  
3 6  
0.1  
0.5 1  
3
6
0.1  
0.5 1  
5 10  
Load Current (A)  
Load Current (A)  
Load Current (A)  
E-10  
www.idec.com  
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC  
Relays  
RU Series  
Dimensions are in mm.  
Maximum Switching Capacity  
RU2 (Maximum Load)  
AC resistive  
AC inductive  
(cos ø = 0.3)  
10  
5
DC resistive  
1
DC inductive  
L/R = 7 ms  
0.1  
10  
30  
100 250500  
Load Voltage(V)  
RU4 (Maximum Load)  
RU42 (Maximum Load)  
AC resistive  
AC resistive  
AC inductive  
(cos ø = 0.3)  
AC inductive  
(cos ø = 0.3)  
E
6
3
6
3
1
1
DC resistive  
DC resistive  
DC inductive  
L/R = 7 ms  
DC inductive  
L/R = 7 ms  
0.1  
0.1  
10  
30  
100 250500  
10  
30  
100 250500  
Load Voltage(V)  
Load Voltage(V)  
Dimensions & Mounting Hole Layouts  
RU4/RU42  
RU2  
Dimensions  
Dimensions  
Marking Plate  
Removal Slot  
Marking Plate  
Removal Slot  
2.6  
1.2 2.2 Hole  
0.5  
2.6  
0.5  
1.2 2.2 Hole  
27.5  
27.5  
Marking plate removal slot is provided only on one side.  
Insert a flat screwdriver into the slot to remove the marking plate.  
Marking plate removal slot is provided only on one side.  
Insert a flat screwdriver into the slot to remove the marking plate.  
Dimensions are in mm.  
www.idec.com  
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC  
E-11  

相关型号:

RU2S-C-A110

RU Series - General Purpose Relays
ETC

RU2S-C-D24

RU Series - General Purpose Relays
ETC

RU2S-M

RU Series - General Purpose Relays
ETC

RU2W

Rectifier Diode, 1 Element, 1A, Silicon
SANKEN

RU2Y

HIGH EFFICIENCY RECTIFIER
BL Galaxy Ele

RU2YX

Fast-Recovery Rectifier Diodes
SANKEN

RU2YX

FAST RECOVERY RECTIFIER DIODE
EIC

RU2YX

HIGH EFFICIENCY RECTIFIER
BL Galaxy Ele

RU2YX

Plastic Ultra-Fast Recover Rectifier Reverse Voltage 100V Forward Current 1.5 A
DACHANG

RU2YXV3

Rectifier Diode, 1 Phase, 1 Element, 1.5A, Silicon,
SANKEN

RU2YXVO

Rectifier Diode, 1 Phase, 1 Element, 1.5A, Silicon,
SANKEN

RU2YXW

Rectifier Diode, 1 Phase, 1 Element, 1.5A, Silicon,
SANKEN