RV-0512D/R6.4 [ETC]
DC DC CONVERTER +/-12V 2W;型号: | RV-0512D/R6.4 |
厂家: | ETC |
描述: | DC DC CONVERTER +/-12V 2W |
文件: | 总6页 (文件大小:809K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• IEC60601-1 for medical applications
• UL/CSA/IEC/EN safety certified and CB report
• 6.4kVDC/1s or 8kVDC/1s reinforced isolation
• Optional continuous short circuit protection
• Efficiency up to 88%
Features
DC/DC Converter
Unregulated
Converters
• Space saving package
• Very low isolation capacitance
RV/R
Description
2 Watt
DIP24
Very high isolation in a small size are the main features of this miniature DIP24 converter, ideal
for highly sophisticated industrial, test and measurement and medical designs where board space is
at a premium.
3
miniature
Single and Dual
Output
Selection Guide
Part
Number
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load(2)
[µF]
RV-xx3.3S (3,4)
RV-xx05S (3,4)
RV-xx09S (3,4)
RV-xx12S (3,4)
RV-xx15S (3,4)
RV-xx3.3D (3,4)
RV-xx05D (3,4)
RV-xx09D (3,4)
RV-xx12D (3,4)
RV-xx15D (3,4)
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3
5
600
400
222
167
132
300
200
111
85
70-78
76-80
78-85
78-85
78-88
70-78
75-82
76-84
78-86
78-86
3300
1200
1200
680
9
12
15
3.3
5
680
1500
470
9
470
12
15
220
RoHS2
+
REACH
compliant
compliant
10 from 10
66
220
E314885
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
UL60950-1 certified
Model Numbering
CAN/CSA-C22.2 No. 60950-1 certified
IEC/EN60950-1 certified
ANSI/AAMI ES60601-1 certified
CAN/CSA-C22.2 No. 60601-1 certified
IEC/EN60601-1 certified
IEC/EN61010 certified
RV-__ __S R
Input Voltage
Output Voltage
Reinforced Isolation(3)
Protection (4)
CB report
Single or Dual
Notes:
Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation
or „/R8“ for 8kVDC/1second isolation
Note4: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Ordering Examples
RV-1212D/R6.4 = 12V Input, 12V Output, Dual, 6.4kVDC/1s isolation
RV-053.3S/P/R8 = 5V Input, 3.3V Output, Single, short circuit protection,8kVDC/1s isolation
www.recom-power.com
REV.: 6/2020
ECO-1
RV/R
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Input Voltage Range
Minimum Load
10ꢀ
0ꢀ
Internal Operating Frequency
Output Ripple and Noise
20kHz
50kHz
85kHz
20MHz BW
200mVp-p
Efficiency vs. Load
RV-xx05S/R6.4 and RV-xx05S/R8
RV-xx05D/R6.4 and RV-xx05D/R8
ꢁꢀꢀ
ꢇꢀ
ꢆꢀ
ꢅꢀ
ꢄꢀ
ꢃꢀ
4ꢀ
ꢂꢀ
2ꢀ
ꢁꢀ
ꢀ
ꢁꢀꢀ
ꢇꢀ
ꢆꢀ
ꢅꢀ
ꢄꢀ
ꢃꢀ
4ꢀ
ꢂꢀ
2ꢀ
ꢁꢀ
ꢀ
ꢀꢃꢀꢃ
ꢁ2ꢀꢃ
24ꢀꢃ
ꢀꢃꢀꢃ
ꢁ2ꢀꢃ
24ꢀꢃ
ꢀ
ꢁꢀ 2ꢀ ꢂꢀ 4ꢀ ꢃꢀ ꢄꢀ ꢅꢀ ꢆꢀ ꢇꢀ ꢁꢀꢀ
ꢀ
ꢁꢀ 2ꢀ ꢂꢀ 4ꢀ ꢃꢀ ꢄꢀ ꢅꢀ ꢆꢀ ꢇꢀ ꢁꢀꢀ
Output Load [%]
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
5.0ꢀ max.
low line to high line
1.2ꢀ of 1.0ꢀ Vin typ.
3.3Vout
5Vout
9, 12, 15Vout
20.0ꢀ max.
15.0ꢀ max.
10.0ꢀ max.
Load Regulation (5)
10ꢀ to 100ꢀ load
Notes:
Note5: Operation below 10ꢀ load will not harm the converter, but specifications may not be met
Tolerance Envelope
9, 12, 15, 24Vout
ꢀꢁꢂꢃ
ꢀꢄꢃ
ꢀꢅꢃ
Vnom
ꢆ2.ꢅꢃ
ꢆꢅꢃ
ꢁꢂ
ꢅꢂ
ꢁꢂꢂ
Output Load [%]
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-2
RV/R
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
Deviation vs. Load
RV-xx05S/R6.4 and RV-xx05S/R8
RV-xx05D/R6.4 and RV-xx05D/R8
2ꢀ
2ꢃ
ꢁꢀ
ꢁꢃ
ꢀ
2ꢀ
2ꢃ
ꢁꢀ
ꢁꢃ
ꢀ
ꢃꢀꢃꢀ
ꢁ2ꢃꢀ
24ꢃꢀ
ꢃꢀꢃꢀ
ꢁ2ꢃꢀ
24ꢃꢀ
ꢃ
ꢃ
ꢂꢀ
ꢂꢀ
ꢂꢁꢃ
ꢂꢁꢃ
ꢃ
ꢁꢃ 2ꢃ ꢄꢃ 4ꢃ ꢀꢃ ꢅꢃ ꢆꢃ ꢇꢃ ꢈꢃ ꢁꢃꢃ
ꢃ
ꢁꢃ 2ꢃ ꢄꢃ 4ꢃ ꢀꢃ ꢅꢃ ꢆꢃ ꢇꢃ ꢈꢃ ꢁꢃꢃ
Output Load [%]
Output Load [%]
PROTECTIONS
Parameter
Type
Value
without suffix
with suffix “/P”
1 second
continuous
Short Circuit Protection (SCP)
tested for 1 second
rated for 1 minute
6.4kVDC
3.2kVAC/60Hz
“/R6.4”
“/R8”
Isolation Voltage (6)
I/P to O/P
tested for 1 second
rated for 1 minute
8kVDC
4kVAC/60Hz
15GΩ min.
Isolation Resistance
Isolation Capacitance
Insulation Grade
Means of Protection
Internal
2pF min. / 12pF max.
reinforced
34Vr.m.s.
2MOPP
clearance/creepage
clearance/creepage
>4.8mm
>4.8mm
External
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 6/2020
ECO-3
RV/R
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
ENVIRONMENTAL
Parameter
Condition
full load @ free air convection (see graph)
Value
-40°C to +85°C
3000m
Operating Temperature Range
Operating Altitude
Operating Humidity
Pollution Degree
non-condensing
95ꢀ RH max.
PD2
+25°C
+85°C
1154 x 103 hours
168 x 103 hours
MTBF
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ free air convection)
ꢅꢁꢁ
ꢈꢁ
ꢇꢁ
ꢂꢁ
ꢃꢁ
ꢆꢁ
4ꢁ
ꢄꢁ
2ꢁ
ꢅꢁ
ꢁ
ꢀ4ꢁ ꢀꢄꢁ ꢀ2ꢁ ꢀꢅꢁ
ꢁ
ꢅꢁ 2ꢁ ꢄꢁ 4ꢁ ꢆꢁ ꢃꢁ ꢂꢁ ꢇꢁ ꢈꢁ ꢅꢁꢁꢅꢅꢁ
ꢇꢆ
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1-03
Information Technology Equipment, General Requirements for Safety
2236395
IEC60950-1-2005 , 2nd Edition + A2:2013
EN60950-1: 2006 + A2:2013
Information Technology Equipment, General Requirements for Safety
LVD1605077-14
E314885-A5-UL
Medical Electrical Equipment Part 1: General Requirements for Basic
Safety and Essential Performance
ANSI/AAMI ES60601-1:2005 + A2:10
CAN/CSA-C22.2 No. 60601-1:2008
Medical Electrical Equipment Part 1: General Requirements for Basic
Safety and Essential Performance (CB Scheme)
E314885-A5-CB-1
WD-SE-R-180539-A0
IEC60601-1:2005 + C2:2007
Medical Electrical Equipment Part 1: General Requirements for Basic
Safety and Essential Performance
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 + A12:2014
Safety requirements for electrical equipment for measurement, control
and laboratory use - Part 1: General requirements
EN61010:2010
IEC61010:2010
T1301251-313
RU-AT.49.09571
EAC
TP TC 004/2011
RoHS 2+
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment -
Emission requirements
with external filter
(refer to “EMC Filter Suggestion” below)
EN55032, Class A
EN55032, Class B
continued on next page
REV.: 6/2020
www.recom-power.com
ECO-4
RV/R
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
EMC Filter Suggestion according to EN55032
L1
+Vin
+Vout
+Vin
-Vin
+Vout
C1
C2
-Vout
-Vin
-Vout
C3
Component List Class A
Model
C1
C2
C3
L1
RV/R6.4
2n2F 8kV
N/A
10µF
N/A
RV/R8
2n5F 10kV
Component List Class B
Model
RV/R6.4
RV/R8
C1
C2
C3
L1
2n2F 8kV
2n5F 10kV
470µH
WE7447471471
10µF
10µF
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
case
potting
PCB
non-conductive black plastic, (UL94 V-0)
silicone, (UL94 V-0)
Material
FR4, (UL94 V-0)
Dimension (LxWxH)
Weight
32.35 x 14.7 x 11.1mm
9.0g typ.
Dimension Drawing (mm)
ꢌ2.ꢌꢂ
embossed logo
Pinning Information
Pin #
1
2
Single
+Vin
-Vin
Dual
+Vin
-Vin
ꢀ4.4
8, 17
NC
NC
-Vout
+Vout
NC
-Vout
NC
Com
+Vout
NC
9, 11, 14
10, 15
12, 13
16, 23, 24
ꢁ.ꢁꢂ
ꢁ.ꢂ
ꢀꢂ.24
ꢀꢋ.ꢊꢂ maꢇ.
Recommended Footprint Details
ꢀ.ꢁꢁꢃ ꢄꢁ.ꢀꢂꢅꢆꢁ
1
2
8
9 10 11 12
24 23
17 16 15 14 13
Top View
NC= No Connection
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
Bottom View
1
2
8 9 10 11 12
24 23
17 16 15 14 13
ꢀꢀꢇ2.ꢂ4ꢈ 2ꢉ.ꢊ4
2.2
2.ꢂ4
www.recom-power.com
REV.: 6/2020
ECO-5
RV/R
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
tube
tube
Value
530.0 x 21.0 x 18.0mm
15pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95ꢀ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 6/2020
ECO-6
相关型号:
©2020 ICPDF网 联系我们和版权申明