RV-0924S/P [ETC]
CONV DC/DC 2W 09VIN 24VOUT;型号: | RV-0924S/P |
厂家: | ETC |
描述: | CONV DC/DC 2W 09VIN 24VOUT 光电二极管 |
文件: | 总6页 (文件大小:919K) |
中文: | 中文翻译 | 下载: | 下载PDF数据表文档文件 |
• UL/CSA/IEC/EN safety certified and CB report
• 6kVDC/1s isolation
• Optional continuous short circuit protection
• Efficiency up to 82%
Features
DC/DC Converter
Unregulated
Converters
• Space saving package
• Very low isolation capacitance
• Suitable for IGBT application
RV
Description
2 Watt
DIP24
Very high isolation in a small size are the main features of this miniature DIP24 converter, ideal
for highly sophisticated industrial, test and measurement and medical designs where board space is
at a premium.
3
miniature
Selection Guide
Part
Number
Single and Dual
Output
nom. Input
Voltage
[VDC]
Output
Voltage
[VDC]
Output
Current
[mA]
Efficiency
typ. (1)
[%]
max. Capacitive
Load(2)
[µF]
RV-xx3.3S(3)
RV-xx05S(3)
RV-xx09S(3)
RV-xx12S(3)
RV-xx15S(3)
RV-xx24S(3)
RV-xx3.3D(3)
RV-xx05D(3)
RV-xx09D(3)
RV-xx12D(3)
RV-xx15D(3)
RV-xx24D(3)
RV-xx1509D
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
3.3, 5, 12, 15, 24
5, 12, 24
3.3
5
600
400
222
167
132
83
70
3300
1200
1200
680
70-75
70-75
70-75
75-80
75-80
70
9
12
15
24
3.3
5
680
220
300
200
111
85
1500
470
70-75
70-75
70-75
75-80
75-80
70-82
RoHS2
+
REACH
compliant
compliant
10 from 10
9
470
E224736
12
15
24
+15/-9
220
66
220
42
100
+67/-111
330
Notes:
UL60950-1 certified
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
CAN/CSA-C22.2 No. 60950-1-07 certified
IEC/EN60950-1 certified
UL62368-1 certified
CAN/CSA-C22.2 No. 62368-1-14 certified
IEC/EN62368-1 certified
CB report
Model Numbering
RV-__ __S
(3)
Input Voltage
“Protection ”
Output Voltage
Single or Dual
Notes:
Note3: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Ordering Examples
RV-053.3S/P = 5V Input, 3.3V Output, Single, short circuit protection
RV-1212D = 12V Input, 12V Output, Dual
www.recom-power.com
REV.: 2/2020
ECO-1
RV
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Input Voltage Range
Minimum Load
10ꢀ
0ꢀ
all others
RV-XX1509D
20kHz
20kHz
50kHz
47kHz
85kHz
Internal Operating Frequency
Output Ripple and Noise
20MHz BW
200mVp-p
Efficiency vs. Load
RV-xx05S
RV-xx12S
ꢁꢀꢀ
ꢇꢀ
ꢆꢀ
ꢅꢀ
ꢄꢀ
ꢃꢀ
4ꢀ
ꢂꢀ
2ꢀ
ꢁꢀ
ꢀ
ꢁꢀꢀ
ꢇꢀ
ꢆꢀ
ꢅꢀ
ꢄꢀ
ꢃꢀ
4ꢀ
ꢂꢀ
2ꢀ
ꢁꢀ
ꢀ
ꢀꢃꢀꢃ
ꢁ2ꢀꢃ
ꢀꢃꢁ2
ꢁ2ꢁ2
ꢀ
ꢁꢀ 2ꢀ ꢂꢀ 4ꢀ ꢃꢀ ꢄꢀ ꢅꢀ ꢆꢀ ꢇꢀ ꢁꢀꢀ
ꢀ
ꢁꢀ 2ꢀ ꢂꢀ 4ꢀ ꢃꢀ ꢄꢀ ꢅꢀ ꢆꢀ ꢇꢀ ꢁꢀꢀ
Output Load [%]
Output Load [%]
RV-xx05D
RV-xx12D
ꢁꢀꢀ
ꢇꢀ
ꢆꢀ
ꢅꢀ
ꢄꢀ
ꢃꢀ
4ꢀ
ꢂꢀ
2ꢀ
ꢁꢀ
ꢀ
ꢁꢀꢀ
ꢇꢀ
ꢆꢀ
ꢅꢀ
ꢄꢀ
ꢃꢀ
4ꢀ
ꢂꢀ
2ꢀ
ꢁꢀ
ꢀ
ꢀꢃꢀꢃ
ꢁ2ꢀꢃ
ꢀꢃꢁ2
ꢁ2ꢁ2
ꢀ
ꢁꢀ 2ꢀ ꢂꢀ 4ꢀ ꢃꢀ ꢄꢀ ꢅꢀ ꢆꢀ ꢇꢀ ꢁꢀꢀ
ꢀ
ꢁꢀ 2ꢀ ꢂꢀ 4ꢀ ꢃꢀ ꢄꢀ ꢅꢀ ꢆꢀ ꢇꢀ ꢁꢀꢀ
Output Load [%]
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
5.0ꢀ typ.
low line to high line
1.2ꢀ of 1.0ꢀ Vin typ.
3.3Vout
5Vout
9, 12, 15, 24 and +15/-9Vout
20.0ꢀ max.
15.0ꢀ max.
10.0ꢀ max.
Load Regulation (4)
10ꢀ to 100ꢀ load
continued on next page
www.recom-power.com
REV.: 2/2020
ECO-2
RV
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
Notes:
Note4: Operation below 10ꢀ load will not harm the converter, but specifications may not be met
Tolerance Envelope
9, 12, 15, 24 and +15/-9Vout
ꢀꢁꢂꢃ
ꢀꢄꢃ
ꢀꢅꢃ
Vnom
ꢆ2.ꢅꢃ
ꢆꢅꢃ
ꢁꢂ
ꢅꢂ
ꢁꢂꢂ
Output Load [%]
Deviation vs. Load
RV-xx05S
RV-xx12S
2ꢀ
2ꢃ
ꢁꢀ
ꢁꢃ
ꢀ
2ꢀ
ꢃꢀꢃꢀ
ꢁ2ꢃꢀ
ꢃꢀꢁ2
ꢁ2ꢁ2
2ꢃ
ꢁꢀ
ꢁꢃ
ꢀ
ꢃ
ꢃ
ꢂꢀ
ꢂꢀ
ꢂꢁꢃ
ꢂꢁꢃ
ꢃ
ꢁꢃ 2ꢃ ꢄꢃ 4ꢃ ꢀꢃ ꢅꢃ ꢆꢃ ꢇꢃ ꢈꢃ ꢁꢃꢃ
ꢃ
ꢁꢃ 2ꢃ ꢄꢃ 4ꢃ ꢀꢃ ꢅꢃ ꢆꢃ ꢇꢃ ꢈꢃ ꢁꢃꢃ
Output Load [%]
Output Load [%]
RV-xx05D
RV-xx12D
2ꢀ
2ꢃ
ꢁꢀ
ꢁꢃ
ꢀ
2ꢀ
2ꢃ
ꢁꢀ
ꢁꢃ
ꢀ
ꢃꢀꢃꢀ
ꢁ2ꢃꢀ
ꢃꢀꢁ2
ꢁ2ꢁ2
ꢃ
ꢃ
ꢂꢀ
ꢂꢀ
ꢂꢁꢃ
ꢂꢁꢃ
ꢃ
ꢁꢃ 2ꢃ ꢄꢃ 4ꢃ ꢀꢃ ꢅꢃ ꢆꢃ ꢇꢃ ꢈꢃ ꢁꢃꢃ
ꢃ
ꢁꢃ 2ꢃ ꢄꢃ 4ꢃ ꢀꢃ ꢅꢃ ꢆꢃ ꢇꢃ ꢈꢃ ꢁꢃꢃ
Output Load [%]
Output Load [%]
www.recom-power.com
REV.: 2/2020
ECO-3
RV
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
PROTECTIONS
Parameter
Type
Value
without suffix
with suffix “/P”
1 second
continuous
Short Circuit Protection (SCP)
tested for 1 second
rated for 1 minute
6kVDC
3kVAC/60Hz
15GΩ min.
Isolation Voltage (5)
I/P to O/P
Isolation Resistance
Isolation Capacitance
2pF min. / 12pF max.
basic (IEC/EN60950-1, IEC/EN62368-1)
functional (IEC/EN60601-1)
Insulation Grade
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note6: Refer to local safety regulations if input over-current protection is required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Operating Temperature Range
Operating Altitude
Condition
full load @ free air convection (see graph)
Value
-40°C to +90°C
3000m
Operating Humidity
Pollution Degree
non-condensing
95ꢀ RH max.
PD2
+25°C
+85°C
1154 x 103 hours
168 x 103 hours
MTBF
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ free air convection)
ꢅꢁꢁ
ꢈꢁ
ꢇꢁ
ꢂꢁ
ꢃꢁ
ꢆꢁ
4ꢁ
ꢄꢁ
2ꢁ
ꢅꢁ
ꢁ
ꢀ4ꢁ ꢀꢄꢁ ꢀ2ꢁ ꢀꢅꢁ
ꢁ
ꢅꢁ 2ꢁ ꢄꢁ 4ꢁ ꢆꢁ ꢃꢁ ꢂꢁ ꢇꢁ ꢈꢁ ꢅꢁꢁꢅꢅꢁ
ꢈꢆ
Ambient Temperature [°C]
www.recom-power.com
REV.: 2/2020
ECO-4
RV
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edtition, 2014
UL No. 60950-1, 2nd Edition, 2014
Information Technology Equipment, General Requirements for Safety
E224736-A56-UL
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety (LVD)
LVD1602031
E224736-A56-UL
WD-SE-R-180541-A0
Audio/Video, information and communication technology equipment -
Part1: Safety requirements
CAN/CSA-C22.2 No. 62368-1-14, 2nd Edition
UL62368-1, 2nd Edition, 2014
Medical Electrical Equipment Part 1: General Requirements for Basic
Safety and Essential Performance
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 + A12:2014
Audio/Video, information and communication technology equipment -
Part1: Safety requirements
EN62368-1:2014 + A11:2017
IEC62368-1:2014 2nd Edition
ATTCB106076
Audio/Video, information and communication technology equipment -
Part1: Safety requirements (CB Scheme)
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS 2
RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
case
potting
PCB
Value
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
Material
FR4, (UL94 V-0)
Dimension (LxWxH)
Weight
32.35 x 14.7 x 11.1mm
9.0g typ.
Dimension Drawing (mm)
ꢌ2.ꢌꢂ
embossed logo
Pinning Information
Pin #
1
2
Single
+Vin
-Vin
Dual
+Vin
-Vin
ꢀ4.4
8, 17
NC
NC
-Vout
+Vout
NC
-Vout
NC
Com
+Vout
NC
9, 11, 14
10, 15
12, 13
16, 23, 24
ꢁ.ꢁꢂ
ꢁ.ꢂ
ꢀꢂ.24
ꢀꢋ.ꢊꢂ maꢇ.
Recommended Footprint Details
ꢀ.ꢁꢁꢃ ꢄꢁ.ꢀꢂꢅꢆꢁ
1
2
8
9 10 11 12
24 23
17 16 15 14 13
Top View
NC= No Connection
Tolerance: xx.x= 0.5mm
xx.xx= 0.25mm
Bottom View
1
2
8 9 10 11 12
24 23
17 16 15 14 13
ꢀꢀꢇ2.ꢂ4ꢈ 2ꢉ.ꢊ4
2.2
2.ꢂ4
www.recom-power.com
REV.: 2/2020
ECO-5
RV
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Series
INSTALLATION AND APPLICATION
IGBT Application Circuit
+
ꢆꢄ
ꢁ
ꢀ
Signal+
Iꢀꢄ
ꢅꢄ
ꢊꢋꢃ
Iꢉ
Iꢁꢂꢃ Driver
-Vin
Signal-
+Vin
ꢇ
+Vout
Iꢀ2
Dꢀ
+Vin
-Vin
Dꢀ
ꢀ2
ꢀꢈ
ꢀꢄ
-Vout
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
tube
tube
Value
530.0 x 21.0 x 18.0mm
15pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
95ꢀ RH max.
non-condensing
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 2/2020
ECO-6
相关型号:
©2020 ICPDF网 联系我们和版权申明