S30 Sensors – ac-Voltage Series  
Self-contained ac-operated sensors  
Features  
®
• Featuring EZ-BEAM technology, the specially designed optics and electronics  
provide reliable sensing without the need for adjustments  
• 30 mm plastic threaded barrel sensor in opposed, retroreflective or fixed-field  
modes  
• Completely epoxy-encapsulated to provide superior durability, even in harsh  
sensing environments rated to IP69K  
• Innovative dual-indicator system takes the guesswork out of sensor performance  
monitoring  
• 20 to 250V ac (3-wire hookup); SPST solid-state switch output, maximum  
load 300 mA  
Models  
Sensing Mode  
Range  
LED  
Output  
Model*  
S303E  
Infrared  
950 nm  
Opposed  
60 m (200')  
LO  
DO  
LO  
DO  
LO  
DO  
LO  
S30AW3R  
S30RW3R  
S30AW3LP  
Polarized  
Retroreflective  
Visible Red  
680 nm  
6 m (20')  
P
S30RW3LP  
S30AW3FF200  
S30RW3FF200  
S30AW3FF400  
200 mm (8") cutoff  
Infrared  
880 nm  
400 mm (16") cutoff  
600 mm (24") cutoff  
Fixed-Field  
DO  
S30RW3FF400  
LO  
DO  
S30AW3FF600  
S30RW3FF600  
* Standard 2 m (6.5') cable models are listed.  
9 m (30') cable: add suffix “W/30” (e.g., S303E W/30).  
4-pin Micro-style QD models: add suffix “Q1” (e.g., S303EQ1). A model with a QD connector requires a mating cable.  
WARNING . . . Not To Be Used for Personnel Protection  
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.  
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety  
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.  
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for  
personnel protection.  
Printed in USA  
01/05  
P/N 121519  
S30 Sensors – ac-Voltage Series  
Fixed-Field Mode Overview  
S30 Series self-contained fixed-field sensors are small, powerful, infrared diffuse mode  
sensors with far-limit cutoff (a type of background suppression). Their high excess gain  
and fixed-field technology allow them to detect objects of low reflectivity, while ignoring  
background surfaces.  
The cutoff distance is fixed. Backgrounds and background objects must always be placed  
beyond the cutoff distance.  
Fixed-Field Sensing – Theory of Operation  
Cutoff  
Distance  
The S30FF compares the reflections of its emitted light beam (E) from an object back to the  
sensor’s two differently aimed detectors, R1 and R2 (see Figure 1). If the near detector (R1)  
light signal is stronger than the far detector (R2) light signal (see object A, closer than the  
cutoff distance), the sensor responds to the object. If the far detector (R2) light signal is  
stronger than the near detector (R1) light signal (see object B, beyond the cutoff distance),  
the sensor ignores the object.  
Object B  
Receiver  
Elements  
Object  
A
or  
Background  
Lenses  
Near  
R1  
R2  
Detector  
Far  
Detector  
The cutoff distance for model S30FF sensors is fixed at 200, 400 or 600 millimeters (8",  
16", or 24"). Objects lying beyond the cutoff distance usually are ignored, even if they are  
highly reflective. However, it is possible to falsely detect a background object, under certain  
conditions (see Background Reflectivity and Placement).  
E
Emitter  
Sensing  
Range  
In the drawings and discussion on these pages, the letters E, R1, and R2 identify how the  
sensor’s three optical elements (Emitter “E”, Near Detector “R1”, and Far Detector “R2”)  
line up across the face of the sensor. The location of these elements defines the sensing  
axis (see Figure 2). The sensing axis becomes important in certain situations, such as those  
illustrated in Figures 5 and 6.  
Object is sensed if amount of light at R1  
is greater than the amount of light at R2  
Figure 1. Fixed-field concept  
Sensor Setup  
Sensing Reliability  
For highest sensitivity, position the target object for sensing at or near the point of  
maximum excess gain. The excess gain curves for these products are shown on page 5.  
Maximum excess gain for all models occurs at a lens-to-object distance of about 40 mm  
(1.5"). Sensing at or near this distance will make maximum use of each sensor’s available  
sensing power. The background must be placed beyond the cutoff distance. (Note that the  
reflectivity of the background surface also may affect the cutoff distance.) Following these  
two guidelines will improve sensing reliability.  
Sensing  
Axis  
R1  
R2  
E
Background Reflectivity and Placement  
Avoid mirror-like backgrounds that produce specular reflections. False sensor response will  
occur if a background surface reflects the sensor’s light more strongly to the near detector,  
or “sensing” detector (R1), than to the far detector, or “cutoff” detector (R2). The result  
is a false ON condition (Figure 3). To cure this problem, use a diffusely reflective (matte)  
background, or angle either the sensor or the background (in any plane) so the background  
does not reflect light back to the sensor (see Figure 4). Position the background as far  
beyond the cutoff distance as possible.  
As a general rule, the most reliable  
sensing of an object approaching from  
the side occurs when the line of approach  
is parallel to the sensing axis.  
An object beyond the cutoff distance, either stationary (and when positioned as shown in  
Figure 5), or moving past the face of the sensor in a direction perpendicular to the sensing  
axis, can cause unwanted triggering of the sensor if more light is reflected to the near  
detector than to the far detector. The problem is easily remedied by rotating the sensor  
90° (Figure 6). The object then reflects the R1 and R2 fields equally, resulting in no false  
triggering. A better solution, if possible, may be to reposition the object or the sensor.  
Figure 2. Fixed-field sensing axis  
Banner Engineering Corp. Minneapolis, MN U.S.A.  
www.bannerengineering.com • Tel: 763.544.3164  
2
P/N 121519  
S30 Sensors – ac-Voltage Series  
Color Sensitivity  
The effects of object reflectivity on cutoff distance, though small, may be important for  
some applications. It is expected that at any given cutoff setting, the actual cutoff distance  
for lower reflectance targets will be slightly shorter than for higher reflectance targets (see  
Figure-of-Merit information on page 5). This behavior is known as color sensitivity.  
For example, an excess gain of 1 (see page 5) for an object that reflects 1/10 as much light  
as the 90% white card is represented by the horizontal graph line at excess gain = 10. An  
object of this reflectivity results in a far limit cutoff of approximately 190 mm (7.5") for the  
200 mm (8") cutoff model, for example; thus 190 mm represents the cutoff for this sensor  
and target.  
These excess gain curves were generated using a white test card of 90% reflectance.  
Objects with reflectivity of less than 90% reflect less light back to the sensor, and thus  
require proportionately more excess gain in order to be sensed with the same reliability as  
more reflective objects. When sensing an object of very low reflectivity, it may be especially  
important to sense it at or near the distance of maximum excess gain.  
Cutoff  
Distance  
#UTOFF  
$ISTANCE  
2ꢂ  
2ꢄ  
%
.EAR $ETECTOR  
&AR $ETECTOR  
%MITTER  
(IGHLY  
2EFLECTIVE  
"ACKGROUND  
Fixed Sensing  
Field  
Reflective  
Background  
3ꢀꢁ&& 3ENSOR  
2ꢂ  
Strong  
Direct  
Reflection  
to R1  
S30FF  
R1  
Core of  
Emitted  
Beam  
R2  
E
Core of  
Emitted  
Beam  
%
Strong  
R1  
R2  
E
=
=
=
Near Detector  
Far Detector  
Emitter  
Direct  
Reflection  
Away  
From Sensor  
Fixed Sensing  
Field  
Figure 3. Reflective background – problem  
Figure 4. Reflective background – solution  
Cutoff  
Distance  
Cutoff  
Distance  
S30FF  
S30FF  
R1  
R2  
E
E, R1, R2  
Fixed  
Sensing  
Field  
Fixed  
Sensing  
Field  
Reflective  
Background  
or  
R1  
R2  
E
=
=
=
Near Detector  
Far Detector  
Emitter  
E
R1  
R2  
=
=
=
Emitter  
Near Detector  
Far Detector  
Moving Object  
A reflective background object in this position or  
moving across the sensor face in this axis and  
direction may cause false sensor response.  
A reflective background object in this position or  
moving across the sensor face in this axis will be  
ignored.  
Figure 5. Object beyond cutoff – problem  
Figure 6. Object beyond cutoff – solution  
Banner Engineering Corp. Minneapolis, MN U.S.A.  
www.bannerengineering.com • Tel: 763.544.3164  
P/N 121519  
3
S30 Sensors – ac-Voltage Series  
Specifications  
Supply Voltage and  
Current  
20 to 250V ac (50/60 Hz)  
Average current: 20 mA  
Peak current: 200 mA @ 20V ac, 500 mA @ 120V ac, 750 mA @ 250V ac  
Supply Protection  
Circuitry  
Protected against transient voltages  
Output Configuration  
SPST solid-state ac switch; three-wire hookup; light operate or dark operate, depending on model  
Light Operate: Output conducts when sensor sees its own (or the emitter’s) modulated light  
Dark Operate: Output conducts when the sensor sees dark  
Output Rating  
300 mA maximum (continuous)  
Fixed-Field models: derate 5 mA/°C above +50° C (+122° F)  
Inrush capability: 1 amp for 20 milliseconds, non-repetitive  
OFF-state leakage current: < 100 microamps  
ON-state saturation voltage: 3V @ 300 mA ac; 2V @ 15 mA ac  
Output Protection  
Circuitry  
Protected against false pulse on power-up  
Output Response Time  
Opposed mode: 16 milliseconds ON, 8 milliseconds OFF  
Other models: 16 milliseconds ON and OFF  
NOTE: 100 millisecond delay on power-up; outputs do not conduct during this time.  
Repeatability  
Opposed mode: 2 milliseconds  
Other models: 4 milliseconds  
Repeatability and response are independent of signal strength  
Indicators  
Two LEDs (Green and Yellow)  
Green ON steady: power to sensor is ON  
Yellow ON steady: sensor sees light  
Yellow flashing: excess gain marginal (1 to 1.5x) in light condition  
Construction  
PBT polyester housing; polycarbonate (opposed-mode) or acrylic lens  
Leakproof design rated NEMA 6P, DIN 40050 (IP69K)  
Environmental Rating  
Connections  
2 m (6.5') attached cable or 4-pin Micro-style quick-disconnect fitting  
Operating Conditions  
Temperature: -40° to +70° C (-40° to +158° F)  
Maximum relative humidity: 90% at 50° C (non-condensing)  
Vibration and Mechanical All models meet Mil. Std. 202F requirements. Method 201A (Vibration; frequency 10 to 60 Hz, max., double  
Shock  
amplitude 0.06" acceleration 10G). Method 213B conditions H&I (Shock: 75G with unit operating; 100G for  
non-operation)  
Certifications  
Banner Engineering Corp. Minneapolis, MN U.S.A.  
www.bannerengineering.com • Tel: 763.544.3164  
4
P/N 121519  
S30 Sensors – ac-Voltage Series  
Performance Curves  
Excess Gain  
Excess Gain  
Beam Pattern  
Performance based on use of a 90% reflectance white test card.  
1000  
1000  
S30 Series  
S30 Series  
S30 Series  
E
X
C
E
S
S
750 mm  
30"  
E
X
C
E
S
S
Opposed Mode  
Ø 16 mm spot size @ 35 mm focus  
Ø 20 mm spot size @ 200 mm cutoff  
500 mm  
250 mm  
0
20"  
10"  
0
Opposed Mode  
100  
10  
100  
10  
Fixed-field mode  
with 200 mm far  
limit cutoff  
250 mm  
500 mm  
750 mm  
10"  
20"  
30"  
Using 18% gray test card: cutoff  
G
A
I
distance will be 95% of value shown.  
Using 6% black test card: cutoff  
distance will be 90% of value shown.  
G
A
I
N
N
0
15 m  
(50')  
30 m  
(100')  
45 m  
(150')  
60 m  
(200')  
75 m  
(250')  
1
1
0.1 m  
(0.33')  
1 m  
(3.3')  
10 m  
(33')  
DISTANCE  
100 m  
(330')  
1 mm  
(0.04")  
10 mm  
(0.4")  
100 mm  
(4")  
1000 mm  
(40")  
DISTANCE  
DISTANCE  
1000  
1000  
S30 Series  
S30 Series  
S30 Series  
Polarized Retro  
E
X
C
E
S
S
150 mm  
6"  
E
X
C
E
S
S
Ø 17 mm spot size @ 35 mm focus  
Ø 25 mm spot size @ 400 mm cutoff  
100 mm  
50 mm  
0
4"  
2"  
0
Polarized Retro  
100  
10  
100  
10  
with BRT-3 Reflector  
Fixed-field mode  
with 400 mm far  
limit cutoff  
with BRT-3 Reflector  
Using 18% gray test card: cutoff  
50 mm  
100 mm  
150 mm  
2"  
4"  
6"  
distance will be 90% of value shown.  
Using 6% black test card: cutoff  
distance will be 85% of value shown.  
G
A
I
G
A
I
N
N
0
1.5 m  
(5')  
3.0 m  
(10')  
4.5 m  
(15')  
6.0 m  
(20')  
7.5 m  
(25')  
1
1
0.01 m  
(0.033')  
0.1 m  
(0.33')  
1 m  
(3.3')  
10 m  
(33')  
1 mm  
(0.04")  
10 mm  
(0.4")  
100 mm  
4")  
1000 mm  
40")  
DISTANCE  
DISTANCE  
DISTANCE  
††Performance based on use of a model BRT-3 retroreflector (3" diameter).  
Actual sensing range may be more or less than specified, depending on the  
efficiency and reflective area of the retroreflector used.  
1000  
S30 Series  
E
X
C
E
S
S
Ø 17 mm spot size @ 35 mm focus  
Ø 30 mm spot size @ 600 mm cutoff  
100  
Fixed-field mode  
with 600 mm far  
limit cutoff  
Using 18% gray test card: cutoff  
distance will be 85% of value shown.  
Using 6% black test card: cutoff  
10  
G
A
I
N
distance will be 75% of value shown.  
1
1 mm  
(0.04")  
10 mm  
(0.4")  
100 mm  
(4")  
1000 mm  
(40")  
DISTANCE  
Focus and spot sizes are typical.  
Banner Engineering Corp. Minneapolis, MN U.S.A.  
www.bannerengineering.com • Tel: 763.544.3164  
P/N 121519  
5
S30 Sensors – ac-Voltage Series  
Dimensions  
QD Models  
Cabled Models  
ꢊꢋꢌꢌꢍꢎꢁꢏꢐꢑ  
ꢒꢓꢔꢕꢓꢔꢁꢖꢗꢘꢙꢚꢛꢔꢍꢜ  
ꢉꢁꢂꢁꢃꢇꢀꢈꢟꢆꢁꢁꢠꢛꢡꢌꢋ  
ꢢꢛꢂꢁꢣꢓꢔꢤ  
ꢃꢉꢁꢞꢜꢍꢥꢙꢘꢋꢘꢆ  
ꢝꢜꢋꢋꢗꢁꢏꢐꢑ  
ꢞꢍꢎꢋꢜꢁꢖꢗꢘꢙꢚꢛꢔꢍꢜ  
ꢦꢄ�ꢁꢧꢁꢅꢀꢈ  
ꢨꢩꢜꢋꢛꢘ  
89.4 mm  
(3.52")  
65.0 mm  
(2.56")  
ꢇꢈꢀ�ꢁꢂꢂꢁ  
ꢃꢉꢀꢈꢇ"ꢆ  
8�ꢀ7ꢁꢂꢂꢁ  
ꢃꢄꢀꢅ8"ꢆ  
Hookups  
QD Emitters  
(4-pin Micro-Style)  
Cabled Emitters  
rd/bk  
20-250V ac  
rd/wh  
bn  
20-250V ac  
rd  
bu  
No connection  
gn  
All Other QD Models  
(4-pin Micro-Style)  
All Other Cabled Models  
rd/bk  
bn  
20-250V ac  
20-250V ac  
rd/wh  
rd  
bu  
bk  
Load  
Load  
gn  
No Connection  
Banner Engineering Corp. Minneapolis, MN U.S.A.  
www.bannerengineering.com • Tel: 763.544.3164  
6
P/N 121519  
S30 Sensors – ac-Voltage Series  
Quick-Disconnect (QD) Cables  
Style  
Model  
Length  
Dimensions  
Pinout  
ø15 mm  
(0.6")  
4-pin  
Micro-style  
Straight  
MQAC-406  
MQAC-415  
MQAC-430  
2 m (6.5')  
5 m (15')  
9 m (30')  
ø 1/2-20UNF-2B  
44 mm max.  
(1.7")  
Green Wire  
Red Wire  
Red/Black  
Wire  
38 mm max.  
(1.5")  
Red/White  
Wire  
4-pin  
Micro-style  
Right-angle  
MQAC-406RA  
MQAC-415RA  
MQAC-430RA  
2 m (6.5')  
5 m (15')  
9 m (30')  
38 mm max.  
(1.5")  
1/2-20UNF-2B  
ø 15 mm  
(0.6")  
WARRANTY: Banner Engineering Corp. warrants its products to be free from defects for one year. Banner Engineering Corp. will repair  
or replace, free of charge, any product of its manufacture found to be defective at the time it is returned to the factory during the warranty  
period. This warranty does not cover damage or liability for the improper application of Banner products. This warranty is in lieu of any  
other warranty either expressed or implied.  
P/N 121519  
Banner Engineering Corp., 9714 Tenth Ave. No., Minneapolis, MN USA 55441 • Phone: 763.544.3164 • www.bannerengineering.com • Email: sensors@bannerengineering.com  

相关型号:

S30RW3LP

Sensors - ac-Voltage
ETC

S30RW3R

Sensors - ac-Voltage
ETC

S30S04F

SEMICONDUCTOR
SHINDENGEN

S30S100CR

Schottky Barrier Power Rectifiers
MOSPEC

S30S120CR

SCHOTTKY BARRIER RECTIFIERS
MOSPEC

S30S20PT

SCHOTTKY BARRIER RECTIFIER
CHENMKO

S30S30

SCHOTTKY BARRIER RECTIFIERS
MOSPEC

S30S30CR

SCHOTTKY BARRIER RECTIFIERS
MOSPEC

S30S30GP

暂无描述
CHENMKO

S30S30PT

SCHOTTKY BARRIER RECTIFIER
CHENMKO

S30S35

SCHOTTKY BARRIER RECTIFIERS
MOSPEC

S30S35CR

SCHOTTKY BARRIER RECTIFIERS
MOSPEC